Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Mais filtros

País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Biomech Eng ; 139(3)2017 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-28024161

RESUMO

The role of trabeculae carneae in modulating left ventricular (LV) diastolic compliance remains unclear. The objective of this study was to determine the contribution of trabeculae carneae to the LV diastolic compliance. LV pressure-volume compliance curves were measured in six human heart explants from patients with LV hypertrophy at baseline and following trabecular cutting. The effect of trabecular cutting was also analyzed with finite-element model (FEM) simulations. Our results demonstrated that LV compliance improved after trabecular cutting (p < 0.001). Finite-element simulations further demonstrated that stiffer trabeculae reduce LV compliance further, and that the presence of trabeculae reduced the wall stress in the apex. In conclusion, we demonstrate that integrity of the LV and trabeculae is important to maintain LV stiffness and loss in trabeculae leads to more LV compliance.


Assuntos
Diástole/fisiologia , Ventrículos do Coração , Miocárdio/metabolismo , Função Ventricular Esquerda , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Cardiovasculares , Estresse Mecânico
2.
Biomed Instrum Technol ; 44(1): 75-83, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20374133

RESUMO

Abstract The Scisense (London, ON, Canada) micro-manometer pressure sensor is currently being used by investigators to evaluate cardiovascular physiology in mice, but has not been validated to date. The purpose of the current study is to compare the 1.2 F Scisense pressure sensor to the current gold standard produced by Millar Instruments (Houston, TX) (1.4 F). In vitro comparisons were preformed including temperature drift, frequency response analysis up to 250 Hz, and damping coefficient and natural frequency determined via a pop test. The authors also performed in vivo comparisons including pressure drift, dose-response studies to IV isoproterenol, maximum adrenergic stimulation with IV dobutamine, and simultaneous placement of both micro-manometer pressure sensors in the same intact murine hearts. The authors conclude that both sensors are equivalent, and that the Scisense pressure sensor represents an alternative to the current gold standard, the Millar micro-manometer pressure sensor for in vivo pressure measurements in the mouse.


Assuntos
Sistema Cardiovascular/patologia , Manometria/instrumentação , Monitorização Ambulatorial/métodos , Animais , Engenharia Biomédica , Dobutamina/farmacologia , Desenho de Equipamento , Equipamentos e Provisões , Ventrículos do Coração/patologia , Manometria/métodos , Camundongos , Camundongos Endogâmicos BALB C , Camundongos Endogâmicos C57BL , Miniaturização , Pressão , Fatores de Tempo
3.
Cancer Cytopathol ; 128(10): 715-724, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32520446

RESUMO

BACKGROUND: The goal of this study was to determine whether the detection of histologically confirmed cases of cervical high-grade squamous intraepithelial lesions or worse (HSIL+) can be increased by having each liquid-based cytology (LBC) slide read by 2 cytotechnologists as part of routine screening. METHODS: Over 36,212 women aged 30 to 64 years participated in the Forwarding Research for Improved Detection and Access for Cervical Cancer Screening and Triage (FRIDA) Study in Mexico between 2013 and 2016. For each participant, 2 cervical samples were collected at the same clinic visit, one to test for high-risk human papillomavirus (hrHPV) and the other for LBC, which was used to triage those with a hrHPV positive result. LBC slides were evaluated by 7 cytotechnologists, with each slide read independently by 2 blinded cytotechnologists. All women with atypical cells of undetermined significance or a worse result were referred to colposcopy for further evaluation and diagnosis. Three pathologists evaluated the biopsy specimens to confirm the final HSIL+ diagnosis. The HSIL+ detection rates for the single versus double reading were estimated and compared. RESULTS: A total of 3,914 women with a positive hrHPV result were triaged with LBC. The first and second cytology readings resulted in 43 HSIL+ cases detected; the double-reading strategy detected 9 additional HSIL+ cases, resulting in a total of 52 HSIL+ cases. The HSIL+ detection rate increased from 10.99/1000 with a single reading to 13.29/1000 with the double-reading strategy (P = .004). CONCLUSION: A 20.9% increase in HSIL+ cases detected was achieved with a double reading of the LBC slides in this sample of hrHPV-positive women.


Assuntos
Citodiagnóstico/estatística & dados numéricos , Detecção Precoce de Câncer/métodos , Papillomaviridae/isolamento & purificação , Infecções por Papillomavirus/complicações , Triagem/normas , Displasia do Colo do Útero/diagnóstico , Neoplasias do Colo do Útero/diagnóstico , Adulto , Colposcopia , Citodiagnóstico/métodos , DNA Viral/análise , DNA Viral/genética , Feminino , Seguimentos , Humanos , México/epidemiologia , Pessoa de Meia-Idade , Papillomaviridae/genética , Infecções por Papillomavirus/virologia , Prognóstico , Neoplasias do Colo do Útero/epidemiologia , Neoplasias do Colo do Útero/virologia , Displasia do Colo do Útero/epidemiologia , Displasia do Colo do Útero/virologia
4.
Rev. Fac. Med. Hum ; 23(4): 32-40, oct.-dic. 2023. tab, graf
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1559072

RESUMO

RESUMEN Introducción: La diabetes continúa siendo una de las principales causas de discapacidad y muerte en la población mundial. Alrededor del 25% de las personas con diabetes desarrollarán una úlcera en alguno de sus miembros pélvicos inferiores. Objetivo: El presente estudio evalúa los aspectos clínicos relacionados con la amputación del miembro inferior pélvico en una cohorte de pacientes con diabetes mellitus. Métodos: Estudio retrospectivo, transversal, realizado en colaboración entre el Instituto Mexicano del Seguro Social y la Facultad de Farmacia de la Universidad Autónoma del Estado de Morelos, implicó una revisión de expedientes de pacientes con diabetes mellitus tipo 2 en el Hospital General Regional "Ignacio García Téllez". Se seleccionaron 100 expedientes clínicos y Electrónicos basados en criterios de inclusión, que incluían edad mayor de 18 años, afiliación en el sitio del estudio, evolución de la diabetes de al menos 10 años, tratamiento farmacológico para la diabetes y diagnóstico de pie diabético con curación completa o amputación como resultado. Los análisis estadísticos se realizaron mediante STATA y se obtuvo aprobación ética. Resultados: Los pacientes con un control glucémico óptimo cuantificando sus niveles de glucosa en ayunas (<130 mg/dl) así como sus valores de hemoglobina glicosilada (< 7%) tuvieron una menor frecuencia de amputaciones (p˂0,001; Chi2) en comparación con aquellos pacientes sin un control glucémico adecuado. Conclusión: Se encontró que ser hombre, valores de hemoglobina glucosilada superiores al 7% y valores promedio de glucosa en ayunas superiores a 130 mg/L aumentan la probabilidad de presentar una amputación de extremidad inferior.


ABSTRACT Introduction: Diabetes continues to be a leading cause of disability and death in the world's population. About 25% of people with diabetes will develop an ulcer in one of their lower pelvic limbs. Objective: The present study evaluates the clinical aspects related to lower pelvic limb amputation in a cohort of patients with diabetes mellitus. Lazarte Echegaray Hospital during the period 2017-2020. Methods: Retrospective, cross-sectional study, conducted in collaboration between the Mexican Institute of Social Security and the School of Pharmacy of the Autonomous University of Morelos State, involved a review of records of patients with type 2 diabetes mellitus at the Regional General Hospital "Ignacio García Téllez". One hundred clinical and electronic records were selected based on inclusion criteria, which included age over 18 years, affiliation at the study site, diabetes evolution of at least 10 years, pharmacological treatment for diabetes and diagnosis of diabetic foot with complete healing or amputation as an outcome. Statistical analyses were performed using STATA and ethical approval was obtained. Results: Patients with optimal glycemic control by quantifying their fasting glucose levels (<130 mg/dl) as well as their glycated hemoglobin values (< 7%) had a lower frequency of amputations (p˂0.001; Chi2) compared to those patients without adequate glycemic control. Conclusion: Being male, glycosylated hemoglobin values greater than 7% and mean fasting glucose values greater than 130 mg/L were found to increase the likelihood of having a lower extremity amputation.

5.
Circulation ; 107(23): 2962-8, 2003 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-12771002

RESUMO

BACKGROUND: It has been hypothesized that because of its rapid heart rate, the intact murine heart functions near maximal contractility in the basal state. If this hypothesis is correct, then the fast and slow components of myocardial length-dependent activation should be blunted compared with larger mammals. METHODS AND RESULTS: Mice (n=24) were anesthetized, and via an open chest, LV pressure-volume relationships were determined by a dual-frequency conductance catheter system. Baseline pressure-volume relationships were determined during transient occlusion of the inferior vena cava, and repeat measurements were made after 1 (n=10) and 7 (n=21) minutes of sustained aortic occlusion. Control experiments were performed in a subset of mice (n=3). For baseline to 1 minute, an increase in afterload (maximal pressure 95+/-9 to 126+/-7 mm Hg; P<0.001) and effective arterial elastance (5.9+/-3.1 to 9.2+/-3.9 mm Hg/microl; P<0.001) resulted in an increase in end-diastolic volume (31+/-8 to 35+/-9 microL; P<0.001). The result was maintenance of stroke volume (17+/-6 to 15+/-6; P=NS) owing to an increase in contractility (leftward shift in V100 [the volume of end-systolic elastance at 100 mm Hg], 24+/-9 to 16+/-5 microL; P<0.001). No additional augmentation of systolic function was found at 7 minutes. CONCLUSIONS: This study demonstrates that the fast phase of length-dependent activation is intact but not the slow phase, consistent with murine myocardium functioning near maximal contractility in the basal state.


Assuntos
Coração/fisiologia , Contração Miocárdica/fisiologia , Animais , Aorta/fisiologia , Pressão Sanguínea/fisiologia , Volume Cardíaco/fisiologia , Diástole/fisiologia , Feminino , Frequência Cardíaca/fisiologia , Hemodinâmica/fisiologia , Camundongos , Especificidade da Espécie , Volume Sistólico/fisiologia , Sístole/fisiologia , Veia Cava Inferior/fisiologia , Função Ventricular Esquerda/fisiologia
6.
Diab Vasc Dis Res ; 1(2): 89-94, 2004 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-16302647

RESUMO

It is unclear whether the increase in availability of substrates for energy production in diabetes can lead to enhanced systolic function early in the disease, before the onset of structural changes to the myocardium. To examine this issue, BKS.Cg-m +/+ Lepr db (db/db) mice with type 2 diabetes and wild type controls had left ventricular pressure-volume relationships determined in situ. We demonstrated that the db/db mice, when compared to their wild type controls, generated greater left ventricular pressure and an enhancement of left ventricular systolic function based on enhanced power/EDV, positive dP/dt, preload recruitable stroke work, dP/dt--EDV relationship, and curvilinear end-systolic elastance. This enhancement in systolic function occurred despite the db/db mice having greater body weight, but similar preload (end-diastolic volume) and afterload (effective arterial elastance). We postulate that the previously described enhancement in renal glomerular filtration rate seen early in type 2 diabetes may be in part due to enhanced left ventricular systolic function early in this disease.


Assuntos
Diabetes Mellitus Tipo 2/fisiopatologia , Função Ventricular Esquerda/fisiologia , Animais , Peso Corporal , Modelos Animais de Doenças , Feminino , Hemodinâmica/fisiologia , Camundongos , Camundongos Mutantes , Sístole , Fatores de Tempo
7.
Heart Rhythm ; 11(11): 2075-83, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24981870

RESUMO

BACKGROUND: Implantable cardioverter-defibrillators monitor intracardiac electrograms (EGMs) to discriminate between ventricular and supraventricular tachycardias. The incidence of inappropriate shocks remains high because of misclassification of the tachycardia in an otherwise hemodynamically stable individual. Coupling EGMs with an assessment of left ventricular (LV) stroke volume (SV) could help in gauging hemodynamics during an arrhythmia and reducing inappropriate shocks. OBJECTIVE: The purpose of this study was to use the admittance method to accurately derive LV SV. METHODS: Ultrasonic flow probe and LV endocardial crystals were used in canines (n = 12) as the standard for LV SV. Biventricular pacing leads were inserted to obtain admittance measurements. A tetrapolar, complex impedance measurement was made between the Bi-V leads. The real and imaginary components of impedance were used to discard the myocardial component from the blood component to derive instantaneous blood conductance (Gb). Alterations in SV were measured during right ventricular pacing, dopamine infusion, and inferior vena cava occlusion. RESULTS: Gb tracks steady-state changes in SV more accurately than traditional magnitude (ie, |Y|, without removal of the muscle signal) during right ventricular pacing and dopamine infusion (P = .004). Instantaneous LV volume also was tracked more accurately by Gb than ∣Y∣ in the subset of subjects that underwent inferior vena cava occlusions (n = 5, P = .025). Finite element modeling demonstrates that admittance shifts more sensitivity of the measurement to the LV blood chamber as the mechanism for improvement (see Online Appendix). CONCLUSION: Monitoring LV SV is possible using the admittance method with biventricular pacing leads. The technique could be piggybacked to complement EGMs to determine if arrhythmias are hemodynamically unstable.


Assuntos
Técnicas Eletrofisiológicas Cardíacas , Volume Sistólico/fisiologia , Taquicardia Ventricular/fisiopatologia , Animais , Modelos Animais de Doenças , Cães , Análise de Elementos Finitos , Hemodinâmica/fisiologia
8.
Biomed Opt Express ; 3(4): 701-14, 2012 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-22574259

RESUMO

Blood flow in murine epicardial and intra-myocardial coronary arteries was measured in vivo with spectral domain optical Doppler tomography (SD-ODT). Videos at frame rates up to 180 fps were collected and processed to extract phase shifts associated with moving erythrocytes in the coronary arteries. Radial averaging centered on the vessel lumen provided spatial smoothing of phase noise in a single cross-sectional frame for instantaneous peak velocity measurement without distortion of the flow profile. Temporal averaging synchronized to the cardiac cycle (i.e., gating) was also performed to reduce phase noise, although resulting in lower flow profiles. The vessel angle with respect to incident imaging beam was measured with three-dimensional raster scans collected from the same region as the high speed cross-sectional scans. The variability in peak phase measurement was 10-15% from cycle to cycle on a single animal but larger for measurements among animals. The inter-subject variability is attributed to factors related to real physiological and anatomical differences, instrumentation variables, and measurement error. The measured peak instantaneous flow velocity in a ~40-µm diameter vessel was 23.5 mm/s (28 kHz Doppler phase shift). In addition to measurement of the flow velocity, we observed several dynamic features of the vessel and surrounding myocardium in the intensity and phase sequences, including asymmetric vessel deformation and rapid flow reversal immediately following maximum flow, in confirmation of known coronary artery flow dynamics. SD-ODT is an optical imaging tool that can provide in vivo measures of structural and functional information on cardiac function in small animals.

9.
J Appl Physiol (1985) ; 110(3): 799-806, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21148342

RESUMO

There are two implanted heart failure warning systems incorporated into biventricular pacemakers/automatic implantable cardiac defibrillators and tested in clinical trials: right heart pressures, and lung conductance measurements. However, both warning systems postdate measures of the earliest indicator of impending heart failure: left ventricular (LV) volume. There are currently no proposed implanted technologies that can perform LV blood volume measurements in humans. We propose to solve this problem by incorporating an admittance measurement system onto currently deployed biventricular and automatic implantable cardiac defibrillator leads. This study will demonstrate that an admittance measurement system can detect LV blood conductance from the epicardial position, despite the current generating and sensing electrodes being in constant motion with the heart, and with dynamic removal of the myocardial component of the returning voltage signal. Specifically, in 11 pigs, it will be demonstrated that 1) a physiological LV blood conductance signal can be derived; 2) LV dilation in response to dose-response intravenous neosynephrine can be detected by blood conductance in a similar fashion to the standard of endocardial crystals when admittance is used, but not when only traditional conductance is used; 3) the physiological impact of acute left anterior descending coronary artery occlusion and resultant LV dilation can be detected by blood conductance, before the anticipated secondary rise in right ventricular systolic pressure; and 4) a pleural effusion simulated by placing saline outside the pericardium does not serve as a source of artifact for blood conductance measurements.


Assuntos
Diagnóstico por Computador/métodos , Ventrículos do Coração/fisiopatologia , Hipertrofia Ventricular Esquerda/diagnóstico , Hipertrofia Ventricular Esquerda/fisiopatologia , Pletismografia de Impedância/métodos , Volume Sistólico , Animais , Impedância Elétrica , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Suínos
10.
Physiol Meas ; 32(6): 701-15, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21606560

RESUMO

This paper presents the design, construction and testing of a device to measure pressure-volume loops in the left ventricle of conscious, ambulatory rats. Pressure is measured with a standard sensor, but volume is derived from data collected from a tetrapolar electrode catheter using a novel admittance technique. There are two main advantages of the admittance technique to measure volume. First, the contribution from the adjacent muscle can be instantaneously removed. Second, the admittance technique incorporates the nonlinear relationship between the electric field generated by the catheter and the blood volume. A low power instrument weighing 27 g was designed, which takes pressure-volume loops every 2 min and runs for 24 h. Pressure-volume data are transmitted wirelessly to a base station. The device was first validated on 13 rats with an acute preparation with 2D echocardiography used to measure true volume. From an accuracy standpoint, the admittance technique is superior to both the conductance technique calibrated with hypertonic saline injections, and calibrated with cuvettes. The device was then tested on six rats with 24 h chronic preparation. Stability of animal preparation and careful calibration are important factors affecting the success of the device.


Assuntos
Volume Cardíaco/fisiologia , Estado de Consciência/fisiologia , Movimento/fisiologia , Telemetria/instrumentação , Telemetria/métodos , Pressão Ventricular/fisiologia , Animais , Condutividade Elétrica , Coração/fisiopatologia , Sistema de Condução Cardíaco/fisiologia , Ratos , Tórax/fisiologia
11.
IEEE Trans Biomed Eng ; 56(8): 2044-53, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19605306

RESUMO

A classic problem in traditional conductance measurement of left ventricular (LV) volume is the separation of the contributions of myocardium from blood. Measurement of both the magnitude and the phase of admittance allow estimation of the time-varying myocardial contribution, which provides a substantial improvement by eliminating the need for hypertonic saline injection. We present in vivo epicardial surface probe measurements of electrical properties in murine myocardium using two different techniques (a digital and an analog approach). These methods exploit the capacitive properties of the myocardium, and both methods yield similar results. The relative permittivity varies from approximately 100,000 at 2 kHz to approximately 5000 at 50 kHz. The electrical conductivity is approximately constant at 0.16 S/m over the same frequency range. These values can be used to estimate and eliminate the time-varying myocardial contribution from the combined signal obtained in LV conductance catheter measurements, thus yielding the blood contribution alone. To study the effects of albumin on the blood conductivity, we also present electrical conductivity estimates of murine blood with and without typical administrations of albumin during the experiment. The blood conductivity is significantly altered (p < 0.0001) by administering albumin (0.941 S/m with albumin, 0.478 S/m without albumin).


Assuntos
Eletrocardiografia/métodos , Coração/fisiologia , Animais , Fenômenos Fisiológicos Sanguíneos , Condutividade Elétrica , Eletrodos , Coração/efeitos dos fármacos , Camundongos , Camundongos Endogâmicos C57BL , Pericárdio/fisiologia , Albumina Sérica/farmacologia , Função Ventricular/fisiologia
12.
J Appl Physiol (1985) ; 107(6): 1693-703, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19696357

RESUMO

The conductance catheter technique could be improved by determining instantaneous parallel conductance (G(P)), which is known to be time varying, and by including a time-varying calibration factor in Baan's equation [alpha(t)]. We have recently proposed solutions to the problems of both time-varying G(P) and time-varying alpha, which we term "admittance" and "Wei's equation," respectively. We validate both our solutions in mice, compared with the currently accepted methods of hypertonic saline (HS) to determine G(P) and Baan's equation calibrated with both stroke volume (SV) and cuvette. We performed simultaneous echocardiography in closed-chest mice (n = 8) as a reference for left ventricular (LV) volume and demonstrate that an off-center position for the miniaturized pressure-volume (PV) catheter in the LV generates end-systolic and diastolic volumes calculated by admittance with less error (P < 0.03) (-2.49 +/- 15.33 microl error) compared with those same parameters calculated by SV calibrated conductance (35.89 +/- 73.22 microl error) and by cuvette calibrated conductance (-7.53 +/- 16.23 microl ES and -29.10 +/- 31.53 microl ED error). To utilize the admittance approach, myocardial permittivity (epsilon(m)) and conductivity (sigma(m)) were calculated in additional mice (n = 7), and those results are used in this calculation. In aortic banded mice (n = 6), increased myocardial permittivity was measured (11,844 +/- 2,700 control, 21,267 +/- 8,005 banded, P < 0.05), demonstrating that muscle properties vary with disease state. Volume error calculated with respect to echo did not significantly change in aortic banded mice (6.74 +/- 13.06 microl, P = not significant). Increased inotropy in response to intravenous dobutamine was detected with greater sensitivity with the admittance technique compared with traditional conductance [4.9 +/- 1.4 to 12.5 +/- 6.6 mmHg/microl Wei's equation (P < 0.05), 3.3 +/- 1.2 to 8.8 +/- 5.1 mmHg/microl using Baan's equation (P = not significant)]. New theory and method for instantaneous G(P) removal, as well as application of Wei's equation, are presented and validated in vivo in mice. We conclude that, for closed-chest mice, admittance (dynamic G(P)) and Wei's equation (dynamic alpha) provide more accurate volumes than traditional conductance, are more sensitive to inotropic changes, eliminate the need for hypertonic saline, and can be accurately extended to aortic banded mice.


Assuntos
Volume Cardíaco/fisiologia , Sistema de Condução Cardíaco/fisiologia , Modelos Cardiovasculares , Animais , Cateterismo Cardíaco , Volume Cardíaco/efeitos dos fármacos , Cardiotônicos/farmacologia , Dobutamina/farmacologia , Eletrodos Implantados , Feminino , Sistema de Condução Cardíaco/efeitos dos fármacos , Camundongos , Solução Salina Hipertônica , Processamento de Sinais Assistido por Computador
13.
Catheter Cardiovasc Interv ; 67(6): 915-23, 2006 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-16602128

RESUMO

OBJECTIVES: The aim of this study was to evaluate the feasibility of optical coherence tomography (OCT) to identify the components of vulnerable plaques in a well-established murine model of human atherosclerosis. BACKGROUND: Although the pathologic features that predict plaque rupture at autopsy are well known, the development of a technology to identify these high risk features in vivo is lacking. OCT uses reflected light to provide histology-like images of plaque with higher resolution than competing imaging modalities. Whether OCT can reliably identify the features of an atherosclerotic plaque that define it as vulnerable-thin fibrous cap, large lipid core, and high percent of lipid in the artery-requires further study. METHODS: OCT images of the atherosclerotic innominate artery segments from the apolipoprotein E knockout (apoE(-/-)) mice were recorded and correlated with histology in both in vivo (n = 7) and well as in ex vivo experiments (n = 12). RESULTS: Excellent correlation between the OCT and histology measurements for fibrous cap thickness, lipid core size, and percentage lipid content was found. The fibrous cap thicknesses examined span those of human fibrous caps known to rupture (< 65 microm). Regions of greatest light reflection in OCT images were observed when calcium hydroxy-apatite was scattered in lipid, less in fibrous tissue, and least in lipid. CONCLUSIONS: These findings suggest that OCT holds promise for the identification of features defining vulnerable plaque including fibrous cap thickness, lipid core size, and the percentage of lipid content.


Assuntos
Aterosclerose/patologia , Tronco Braquiocefálico/patologia , Tomografia de Coerência Óptica , Animais , Apolipoproteínas E/deficiência , Apolipoproteínas E/genética , Aterosclerose/genética , Modelos Animais de Doenças , Estudos de Viabilidade , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Knockout , Ruptura Espontânea
14.
Am J Physiol Heart Circ Physiol ; 291(4): H1659-69, 2006 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-16699072

RESUMO

Conductance measurements for generation of an instantaneous left ventricular (LV) volume signal in the mouse are limited, because the volume signal is a combination of blood and LV muscle, and only the blood signal is desired. We have developed a conductance system that operates at two simultaneous frequencies to identify and remove the myocardial contribution to the instantaneous volume signal. This system is based on the observation that myocardial resistivity varies with frequency, whereas blood resistivity does not. For calculation of LV blood volume with the dual-frequency conductance system in mice, in vivo murine myocardial resistivity was measured and combined with an analytic approach. The goals of the present study were to identify and minimize the sources of error in the measurement of myocardial resistivity to enhance the accuracy of the dual-frequency conductance system. We extended these findings to a gene-altered mouse model to determine the impact of measured myocardial resistivity on the calculation of LV pressure-volume relations. We examined the impact of temperature, timing of the measurement during the cardiac cycle, breeding strain, anisotropy, and intrameasurement and interanimal variability on the measurement of intact murine myocardial resistivity. Applying this knowledge to diabetic and nondiabetic 11- and 20- to 24-wk-old mice, we demonstrated differences in myocardial resistivity at low frequencies, enhancement of LV systolic function at 11 wk and LV dilation at 20-24 wk, and histological and electron-microscopic studies demonstrating greater glycogen deposition in the diabetic mice. This study demonstrated the accurate technique of measuring myocardial resistivity and its impact on the determination of LV pressure-volume relations in gene-altered mice.


Assuntos
Sistema de Condução Cardíaco/fisiologia , Coração/fisiologia , Contração Miocárdica/fisiologia , Resistência Vascular/fisiologia , Função Ventricular Esquerda/fisiologia , Animais , Volume Sanguíneo/genética , Volume Sanguíneo/fisiologia , Diabetes Mellitus Experimental/genética , Diabetes Mellitus Experimental/patologia , Diabetes Mellitus Experimental/fisiopatologia , Eletrofisiologia , Feminino , Frequência Cardíaca/genética , Frequência Cardíaca/fisiologia , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Mutantes , Contração Miocárdica/genética , Miocárdio/patologia , Temperatura , Resistência Vascular/genética , Função Ventricular Esquerda/genética
15.
Conf Proc IEEE Eng Med Biol Soc ; 2004: 3674-7, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-17271090

RESUMO

Cardiac volume can be estimated by a conductance catheter system. Both blood and myocardium are conductive, but only the blood conductance is desired. Therefore, the parallel myocardium contribution should be removed from the total measured conductance. Several methods have been developed to estimate the contribution from myocardium, and they only determine a single steady state value for the parallel contribution. Besides, myocardium was treated as purely resistive or mainly capacitive when estimating the myocardial contribution. We question these assumptions and propose that the myocardium is both resistive and capacitive, and its contribution changes during a single cardiac cycle. In vivo magnitude and phase experiments were performed in mice to confirm this hypothesis.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa