Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 51
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Vox Sang ; 118(9): 763-774, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37608544

RESUMO

BACKGROUND AND OBJECTIVES: Human neutrophil antigens (HNAs) are categorized into five systems: HNA-1 to HNA-5. Given the importance of neutrophils in immunity, we sought to create awareness of the role of HNA diagnostic services in managing immune neutropenia and transfusion-related acute lung injury. To provide health communities all around the world with access to these services, we conducted a survey to create a directory of these HNA diagnostic services. MATERIALS AND METHODS: An Excel table-based survey was created to capture information on the laboratory's location and was emailed to 55 individuals with known or possible HNA investigation activity. The collected data were then summarized and analysed. RESULTS: Of contacted laboratories, the surveys were returned from 23 (38.2%) laboratories; 17 have already established HNA diagnostic (of them 12 were regular participants of the International Granulocyte Immunobiology Workshop [ISBT-IGIW]), 4 laboratories were in the process of establishing their HNA investigation and the remaining 2 responder laboratories, did not conduct HNA investigations. In established laboratories, investigation for autoimmune neutropenia (infancies and adults) was the most frequently requested, and antibodies against HNA-1a and HNA-1b were the most commonly detected. CONCLUSION: The directory of survey respondents provides a resource for health professionals wanting to access HNA diagnostic services. The present study offers a comprehensive picture of HNA diagnostics (typing and serology), identifying weak points and areas for improvement for the first time. Identifying more laboratories involved in HNA diagnostics with limited access to international societies in the field will globally improve HNA diagnostics.


Assuntos
Neutropenia , Neutrófilos , Adulto , Humanos , Granulócitos , Anticorpos , Inquéritos e Questionários
2.
Pediatr Allergy Immunol ; 34(7): e13990, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37492921

RESUMO

BACKGROUND: In order to support the comprehensive classification of Leukocyte Adhesion Deficiency-I (LAD-I) severity by simultaneous screening of CD11a/CD18, this study assessed clinical, laboratory, and genetic findings along with outcomes of 69 LAD-I patients during the last 15 years. METHODS: Sixty-nine patients (40 females and 29 males) with a clinical phenotype suspected of LAD-I were referred to Immunology, Asthma, and Allergy research institute, Tehran, Iran between 2007 and 2022 for further advanced immunological screening and genetic evaluations as well as treatment, were enrolled in this study. RESULTS: The diagnosis median age of the patients was 6 months. Delayed umbilical cord separation was found in 25 patients (36.2%). The median diagnostic delay time was 4 months (min-max: 0-82 months). Forty-six patients (66.7%) were categorized as severe (CD18 and/or CD11a: below 2%); while 23 children (33.3%) were in moderate category (CD18 and/or CD11a: 2%-30%). During the follow-ups, 55.1% of children were alive with a mortality rate of 44.9%. Skin ulcers (75.4%), omphalitis (65.2%), and gingivitis (37.7%) were the most frequent complaints. Genetic analysis of the patients revealed 14 previously reported and three novel pathogenic mutations in the ITGB2 gene. The overall survival of patients with and without hematopoietic stem cell transplantation was 79.3% and 55.6%, respectively. CONCLUSION: Physicians' awareness of LAD-I considering delayed separation of umbilical cord marked neutrophilic leukocytosis, and variability in CD11 and CD18 expression levels, and genetic analysis leads to early diagnosis and defining disease severity. Moreover, the prenatal diagnosis would benefit families with a history of LAD-I.


Assuntos
Antígenos CD18 , Síndrome da Aderência Leucocítica Deficitária , Masculino , Gravidez , Feminino , Humanos , Antígenos CD18/genética , Síndrome da Aderência Leucocítica Deficitária/diagnóstico , Síndrome da Aderência Leucocítica Deficitária/genética , Diagnóstico Tardio , Irã (Geográfico) , Leucócitos/metabolismo
3.
Adv Exp Med Biol ; 1367: 119-135, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35286694

RESUMO

Lichen planus (LP) is a multifaceted autoimmune disease affecting the skin, nails, hair, and mucous membranes, with several clinical subgroups. Cell-mediated immunity plays a key role in its progression. This chapter reviews the known genetic associations of lichen planus including HLA as well as non-HLA genes.


Assuntos
Doenças Autoimunes , Líquen Plano , Cabelo , Humanos , Imunogenética , Líquen Plano/genética , Pele
4.
BMC Infect Dis ; 21(1): 1278, 2021 Dec 24.
Artigo em Inglês | MEDLINE | ID: mdl-34952570

RESUMO

BACKGROUND: Preliminary studies revealed the safety and effectiveness of convalescent plasma (CP) therapy for patients with coronavirus. In this study, we aimed to evaluate and summarize the available evidence on CP therapy, identify the research gap regarding the immunological response to CP therapy and pave the road for future studies. METHODS: This study was conducted according to the Hilary Arksey and Lisa O'Malley framework. To find out the relevant studies, we searched PubMed, Scopus and Embase databases up to 30th May 2021. Data have been extracted according to three categories: (1) patients' characteristics, (2) clinical and immunological responses to CP therapy and (3) pre-infusion screening of the CP samples. RESULTS: A total of 12,553 articles were identified. One hundred fifty-four studies met the inclusion criteria for full-text review. More than half of the included studies (112 studies, (75.6%)) concluded satisfactory outcomes and or safety of CP infusion in patients. Results of studies showed the efficacy of CP therapy in clinical improvement (101 studies), decreasing in the level of inflammatory factors (62 studies), elimination or decreasing in viral load (60 studies), and induction or increase in antibody response (37 studies). Despite these promising results, the results of the 49 studies revealed that CP therapy was ineffective in the survival of patients, clinical improvement, viral infection elimination or decrease in the inflammatory factor levels. Furthermore, the adaptive immune response was evaluated in 3 studies. Information related to the pre-infusion screening for human leukocyte antigen/human neutrophil antigen (HLA/HNA) antibodies was not reported in most of the studies. Our gap analysis revealed that the influence of the CP infusion on the adaptive immune and inflammatory responses in patients with coronavirus needs further investigation. CONCLUSIONS: Based on the results of most included studies, CP infusion was safe and resulted in clinical improvement of patients and decreasing the viral load. The effect of the CP infusion on adaptive immune response and inflammatory cytokines in patients with coronavirus needs further investigation.


Assuntos
COVID-19 , Transfusão de Sangue , Humanos , Imunização Passiva , Plasma , SARS-CoV-2
5.
Epilepsy Behav ; 116: 107775, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33571837

RESUMO

Sudden Unexpected Death in Epilepsy (SUDEP) is strongly linked to prone position in the immediate aftermath of a generalized tonic-clonic seizure (GTCS). The risk of SUDEP after a GTCS resulting in prone position has not yet been estimated. We calculated the probability of SUDEP given prone position after a GTCS using Bayesian analysis with inputs obtained from known risk of SUDEP and probability of prone position after a GTCS. The risk for SUDEP given the prone position is estimated to be 0.41% (95% Credible Interval 0.13-0.69%). The relative risk of SUDEP in prone vs. non-prone position following a GTCS is estimated to be 63 (95% Credible Interval 30-96). Sudden Unexpected Death in Epilepsy might be prevented by repositioning the patient after a seizure to avoid the prone position.


Assuntos
Morte Súbita Inesperada na Epilepsia , Teorema de Bayes , Morte Súbita/epidemiologia , Morte Súbita/etiologia , Humanos , Probabilidade , Decúbito Ventral
6.
Neurocrit Care ; 32(1): 162-171, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31093884

RESUMO

BACKGROUND: The objective of this study was to examine whether heart rate variability (HRV) measures can be used to detect neurocardiogenic injury (NCI). METHODS: Three hundred and twenty-six consecutive admissions with aneurysmal subarachnoid hemorrhage (SAH) met criteria for the study. Of 326 subjects, 56 (17.2%) developed NCI which we defined by wall motion abnormality with ventricular dysfunction on transthoracic echocardiogram or cardiac troponin-I > 0.3 ng/mL without electrocardiogram evidence of coronary artery insufficiency. HRV measures (in time and frequency domains, as well as nonlinear technique of detrended fluctuation analysis) were calculated over the first 48 h. We applied longitudinal multilevel linear regression to characterize the relationship of HRV measures with NCI and examine between-group differences at baseline and over time. RESULTS: There was decreased vagal activity in NCI subjects with a between-group difference in low/high frequency ratio (ß 3.42, SE 0.92, p = 0.0002), with sympathovagal balance in favor of sympathetic nervous activity. All time-domain measures were decreased in SAH subjects with NCI. An ensemble machine learning approach translated these measures into a classification tool that demonstrated good discrimination using the area under the receiver operating characteristic curve (AUROC 0.82), the area under precision recall curve (AUPRC 0.75), and a correct classification rate of 0.81. CONCLUSIONS: HRV measures are significantly associated with our label of NCI and a machine learning approach using features derived from HRV measures can classify SAH patients that develop NCI.


Assuntos
Frequência Cardíaca/fisiologia , Volume Sistólico , Hemorragia Subaracnóidea/fisiopatologia , Disfunção Ventricular Esquerda/fisiopatologia , Adulto , Idoso , Isquemia Encefálica/etiologia , Ecocardiografia , Eletrocardiografia , Feminino , Escala de Coma de Glasgow , Humanos , Masculino , Pessoa de Meia-Idade , Índice de Gravidade de Doença , Hemorragia Subaracnóidea/complicações , Troponina I/sangue , Disfunção Ventricular Esquerda/sangue , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/etiologia
7.
Scand J Immunol ; 89(1): e12730, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30375024

RESUMO

All stages of the inflammatory process involved in T cell-mediated chronic skin disorders like psoriasis are affected by redox imbalance. On the other hand, Th17 cells have a critical role in the pathogenesis of psoriasis. In this study, we evaluated redox status in memory CD4 + T cells and plasma of patients with psoriasis and its correlation with IL-17 response. To this end, memory T cells were isolated from 10 patients with psoriasis and 10 controls. Intracellular Glutathione (GSH), reactive oxygen species (ROS) and superoxide as well as IL-17 were measured using flow cytometry. Plasma total anti-oxidant capacity (TAC) was quantified by ferric reducing ability of plasma (FRAP) assay. The expression of catalase (CAT), superoxide dismutase 1(SOD1), superoxide dismutase 2 (SOD2), nuclear factor, erythroid 2 like 2 (NFE2L2) and cytochrome b-245 beta chain (CYBB) genes were analysed using real-time PCR. Our results showed an increased intracellular ROS production in memory CD4 + T cells of patients compared to controls, (P = 0.04). Furthermore, a significant decrease in expression of catalase gene was found in patients, (P = 0.02). However, no significant differences were observed for intracellular GSH, IL-17 and TAC levels between patients and controls. Also, no correlation was seen between the intracellular IL-17 level and intracellular ROS, GSH and catalase gene expression levels. Collectively, we found an increased ROS production in stimulated memory T cells of patients that could be due to reduced expression of catalase gene. However, it seems that these redox abnormalities have no relationship with IL-17 response in memory T cells.


Assuntos
Memória Imunológica/imunologia , Interleucina-17/imunologia , Psoríase/imunologia , Células Th17/imunologia , Adolescente , Adulto , Linfócitos T CD4-Positivos/imunologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Oxirredução , Adulto Jovem
9.
Cell Biol Int ; 43(12): 1332-1345, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31166051

RESUMO

Apelin, a member of the adipokine family, is widely distributed in the body and exerts cytoprotective effects on many organs. Apelin isoforms are involved in different physiological processes, including regulation of the cardiovascular system, cardiac contractility, angiogenesis, and energy metabolism. Several investigations have been performed to study the effect of apelin on stem cell therapy. This review aims to summarize the literature representing the effects of apelin on stem cell properties. Furthermore, this review discusses the therapeutic potential of apelin-treated stem cells for cardiovascular diseases and demonstrates the effect of stem cells overexpressing apelin on energy metabolism. Stem cells with their unique characteristics play a crucial role in the maintenance of tissue integrity. These cells participate in tissue regeneration via multiple mechanisms. Although preclinical and clinical studies have demonstrated the therapeutic potential of stem cells in various diseases, their application in regenerative medicine has not been efficient. A number of strategies such as genetic modification or treatment of stem cells with different factors have been used to improve the efficacy of cell therapy and to increase their survival after transplantation. This article reviews the effect of apelin treatment on the efficacy of cell therapy.

10.
Gen Dent ; 66(2): 64-68, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29513239

RESUMO

One common cause for the replacement of a composite restoration is discoloration. This in vitro study evaluated the effect of tea solution on the discoloration of 3 types of composites at different timepoints after curing. For this study, 150 disc-shaped specimens of 3 types of composite resin-a nanohybrid (Filtek Z350), a microhybrid (Filtek Z250), and a microfilled material (Heliomolar)-were prepared. Specimens were randomly divided into 5 subgroups (n = 10) according to the type of composite and the time from curing to immersion in a tea solution (none [immersed immediately], 1 hour, 6 hours, 12 hours, or 24 hours postcuring). The color for all specimens was measured before and after immersion in tea. Color change (ΔE*) for all specimens was measured, and a ΔE* value of less than 3.3 was considered clinically acceptable. Analysis of variance and a post hoc Tukey test were used to analyze the data (α = 0.05). Immediately after curing, the levels of composite discoloration were deemed clinically acceptable (ΔE* < 3.3). In all composites, the greatest color change was found immediately after curing (P < 0.05). With each subsequent timepoint, the color stability increased. When the groups were immersed in tea 6 hours postcuring, the mean ΔE* value of the Filtek Z350 composite resin specimens was significantly greater than that of Heliomolar specimens (P < 0.05). The mean ΔE* value for specimens immersed 12 hours postcuring was also greater in the Filtek Z250 composite group than in the Heliomolar group (P < 0.05). The ΔE* values of Filtek Z350 and Filtek Z250 composites were not significantly different from each other (P > 0.05), except with 12-hour postcure immersion. The results suggest that patients should avoid the intake of staining foods or beverages for at least 12 hours after placement of a composite resin restoration, although this restriction may be reduced to 1 hour for microfilled composite resins.


Assuntos
Resinas Compostas/química , Materiais Dentários/química , Chá , Descoloração de Dente/induzido quimicamente , Resinas Acrílicas , Técnicas In Vitro , Cura Luminosa de Adesivos Dentários , Teste de Materiais , Poliuretanos , Propriedades de Superfície , Fatores de Tempo
11.
Gen Dent ; 66(1): 40-44, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29303753

RESUMO

Bleaching is a conservative treatment for discolored teeth, but the effect of this treatment on newer, silorane-based composite resins is unclear. This study evaluated the effect of at-home bleaching on the microhardness of methacrylate- and silorane-based composites. Forty blocks each of a methacrylate-based composite and a silorane-based composite were prepared. The 80 specimens were tested in 8 groups (n = 10): 2 composites, each exposed to 3 different carbamide peroxide concentrations (10%, 16%, or 22%) as well as distilled water (control). The surface of the test specimens was covered daily with the bleaching gel at room temperature for the time period recommended by the manufacturer for each carbamide peroxide concentration. A Vickers hardness testing machine was used with a 100-g load for 20 seconds to register specimen microhardness prior to and after 2 weeks of bleaching. The load was applied at 3 points, and the mean microhardness was calculated. Repeated-measures analysis of variance, paired t test, and Tukey test were used to analyze the data. All bleaching concentrations significantly decreased the microhardness of the methacrylate-based composite resin groups, while microhardness was significantly increased in the silorane-based composite resin groups. There was no evident difference in effects among the different gel concentrations (P > 0.05).


Assuntos
Peróxido de Carbamida/farmacologia , Resinas Compostas , Clareadores Dentários/farmacologia , Peróxido de Carbamida/efeitos adversos , Resinas Compostas/química , Relação Dose-Resposta a Droga , Dureza/efeitos dos fármacos , Testes de Dureza , Humanos , Metacrilatos , Resinas de Silorano , Clareadores Dentários/efeitos adversos
12.
Clin Exp Dent Res ; 10(3): e884, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38798053

RESUMO

OBJECTIVES: This study compared the effects of glazing versus polishing on mechanical, optical, and surface properties of zirconia ceramics with different translucencies. MATERIALS AND METHODS: In this in vitro study, 120 bar-shaped specimens (25 × 4 × 1.2 mm) were fabricated from three different types of zirconia with different translucencies (n = 40, DD Bio ZW, ZX2, and Cube X2). After sintering, each zirconia group was randomly divided into five subgroups of control (glazing), glazing + bur abrasion, glazing + bur abrasion + polishing with EVE Diacera® kit, glazing + bur abrasion + reglazing, and glazing + bur abrasion + polishing with EVE Diacera® kit + reglazing. The specimens underwent surface roughness, hardness, flexural strength, and translucency tests, as well as X-ray diffraction (XRD) and scanning electron microscopy (SEM) for assessment of surface topography. Data were analyzed by one-way analysis of variance, Tukey test, and Pearson test (α = .05). RESULTS: Flexural strength, surface hardness, and translucency were significantly correlated with zirconia type. ZW zirconia had significantly higher flexural strength and surface hardness and significantly lower translucency than Cube X2 and ZX2 (p < .001). Surface roughness had no significant correlation with zirconia type (p = .274). Polishing created the smoothest, and bur abrasion created the roughest surface (p < .001). Flexural strength and hardness in most experimental groups were significantly lower than in the control group (p < .001). Translucency was not significantly different in bur abrasion and polishing groups, compared with the control group; however, reglazing significantly increased the translucency (p < .001). SEM micrographs confirmed the surface roughness results. XRD showed monoclinic phase only in reglazed groups. CONCLUSION: Of different surface treatments, polishing improved the surface properties and caused the smallest change in mechanical properties of zirconia with different translucencies.


Assuntos
Cerâmica , Polimento Dentário , Teste de Materiais , Microscopia Eletrônica de Varredura , Propriedades de Superfície , Zircônio , Zircônio/química , Polimento Dentário/métodos , Cerâmica/química , Dureza , Materiais Dentários/química , Resistência à Flexão , Difração de Raios X , Técnicas In Vitro
13.
Dent Res J (Isfahan) ; 21: 18, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38476712

RESUMO

Background: This study aimed to assess the effect of polishing versus glazing of computer-aided design-computer-aided manufacturing (CAD-CAM) ceramics on depth of wear and surface roughness of opposing composite resin. Materials and Methods: This in vitro study was conducted on 40 Z250 composite and 40 CAD-CAM ceramic specimens including Celtra Duo, Vita Mark II, e.max CAD, and Vita Suprinity ceramics. All ceramic specimens were roughened by a fine-grit bur after primary glazing to simulate an adjusted surface in the clinical setting. They were then randomly assigned to two subgroups and underwent reglazing or polishing. All composite and ceramic specimens underwent profilometry after surface treatment and prior to the wear test, and the results were recorded quantitatively. Composite specimens were then subjected to 120,000 wear cycles against ceramic specimens in a chewing simulator, and the depth of wear was measured by a scanner. Data were statistically analyzed by repeated measures two-way analysis of variance (ANOVA) and one-way ANOVA (α = 0.05). Results: Comparison of the surface roughness of composite specimens before and after the wear test revealed significant differences in both glazed Suprinity (P = 0.048) and Vita Mark II (P = 0.026) ceramics groups. The change in surface roughness after the wear test (compared with baseline) was significant in glazed (P = 0.000) and polished (P = 0.013) Vita Mark II and polished Suprinity (P = 0.037) ceramics, but this change was not significant in other ceramics (P > 0.05). The depth of wear after the wear test was not significantly different among the ceramic and composite subgroups (P > 0.05). Conclusion: Assessment of depth of wear and surface roughness of composite specimens showed that the polishing kits of CAD-CAM ceramics can serve as a suitable alternative to reglazing.

14.
Front Dent ; 20: 9, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37312827

RESUMO

Objectives: This study aimed to assess the microtensile bond strength (µTBS) of etch-and-rinse (E&R), self-etch (SE), and universal adhesives to superficial and deep dentin. Materials and Methods: In this in vitro study, 40 sound third molars were randomly divided into two main groups of superficial and deep dentin. Based on our classification, superficial dentin was right beneath the deepest occlusal groove, and deep dentin was 2mm beneath the deepest occlusal groove. Each group was divided into 4 subgroups (n=20) for application of Adper Single Bond 2 (ASB), Clearfil SE Bond (CSE), and Scotchbond Universal (SBU) in E&R and SE modes along with Charisma Smart composite resin on dentin. The specimens were incubated in distilled water at 37°C for 24 hours and their µTBS was then measured. The mode of failure was determined under a stereomicroscope at ×40 magnification. Data were analyzed by one-way ANOVA (alpha=0.05). Results: The highest µTBS belonged to the superficial dentin/SBU/E&R group. The µTBS was significantly higher in superficial dentin than deep dentin for all adhesives (P=0.005). There was no significant difference in mode of failure among the groups. Conclusion: Based on the results obtained in the present study, type of bonding agent and application mode affected µTBS. In use of universal adhesive, E&R mode can improve µTBS.

15.
Front Dent ; 20: 10, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37312832

RESUMO

Objectives: The durability of composite restorations is directly affected by the mechanical properties of the composite. The aim of this study was to evaluate the hardness and wear resistance of self-adhesive flowable composite (SAF) in comparison with conventional flowable composites. Materials and Methods: In this in vitro study, 50 composite specimens were prepared in brass molds with 10mm ×10mm ×2mm and divided into five groups (n=10). Specimens included three conventional flowable composites (Grandio flow, Filtek flow and Admira fusion flow), one self-adhering flowable composite (SAF, Vertise flow) and a microhybrid composite (filtek z250). After polishing, the micro-hardness of the specimens was measured in a Vickers hardness device, and the specimens were then subjected to 5000, 10000, 20000, 40000, 80000 and 120000 wear cycles in a wear tester. One-way ANOVA/Games-Howell, Kruskal Wallis, and Friedman tests were used for statistical analysis. The significance level was set at P<0.05. Results: The surface micro-hardness of the SAF was significantly lower than that of the microhybrid composite (P=0.01). There was no significant difference between the surface hardness of the different tested flowable composites (P>0.05). Also, the wear resistance of the studied composites was not significantly different in various cycles (P>0.05). Conclusion: Based on our results, SAF would not be an ideal substitute for conventional flowable composites in high-stress areas.

16.
Iran J Allergy Asthma Immunol ; 22(5): 468-481, 2023 Oct 29.
Artigo em Inglês | MEDLINE | ID: mdl-38085148

RESUMO

Many studies have evaluated the possible utility of cycle threshold (Ct) values as a predictor of Coronavirus disease 2019 (COVID-19) severity and patient outcome. Given the inconsistent results, we aimed to evaluate the association between severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) Ct values and disease severity, inflammatory markers, and outcomes in Iranian patients with COVID-19. A retrospective study of 528 patients with COVID-19 hospitalized from September 2020 to October 2021 was conducted. Demographic, clinical, and laboratory data of patients were retrieved from electronic medical records. Ct values were analyzed as a continuous variable after subcategorizing into 3 groups: low (Ct values<20), medium (Ct values 20 to 30), and high (Ct values>30). Of the 528 patients (45.1% female) aged 13 to 97 years, 109 patients had low Ct values, 312 patients had medium, and 107 patients had high Ct values. Patients with low Ct values were more likely to present with critical COVID-19, require invasive mechanical ventilation and develop complications such as acute respiratory distress syndrome and pneumonia. Furthermore, patients with low or medium Ct values were more likely to die compared to patients with high Ct values. Multivariate analysis showed that patients with low or medium Ct values were more likely to have severe COVID-19 compared with patients with high Ct values. The multivariate analysis also showed a higher risk of mortality in patients with low Ct values compared to patients with high Ct values, although this was not statistically significant. Our findings revealed that Ct values were an independent predictor of COVID-19 severity. The risk of mortality was higher in patients with low Ct values. However, further investigation is needed to address the correlation between Ct values and inflammatory factors.


Assuntos
COVID-19 , Humanos , Feminino , Masculino , SARS-CoV-2 , Estudos Retrospectivos , Irã (Geográfico)/epidemiologia , Biomarcadores
17.
Neurology ; 101(13): e1359-e1363, 2023 09 26.
Artigo em Inglês | MEDLINE | ID: mdl-37202163

RESUMO

OBJECTIVES: The purpose of this report was to study the incidence of sudden unexpected death in epilepsy (SUDEP) after laser interstitial thermal therapy (LITT) for drug-resistant epilepsy (DRE). METHODS: A prospective observational study of consecutive patients treated with LITT between 2013 and 2021 was conducted. The primary outcome was the occurrence of SUDEP during postoperative follow-up. Surgical outcome was classified according to the Engel scale. RESULTS: There were 5 deaths, including 4 SUDEPs, among 135 patients with a median follow-up duration of 3.5 (range 0.1-9.0) years and a total of 501.3 person-years at risk. The estimated incidence of SUDEP was 8.0 (95% CI 2.2-20.4) per 1,000 person-years. Three SUDEPs occurred in patients with poor seizure outcomes, whereas 1 patient was seizure-free. Compared with pooled historical data, SUDEP occurred at a higher rate than in cohorts treated with resective surgery and at a rate similar to nonsurgical controls. DISCUSSION: SUDEP occurred early and late after mesial temporal LITT. The SUDEP rate was comparable with rates reported in epilepsy surgery candidates who did not receive intervention. These findings reinforce targeting seizure freedom to decrease SUDEP risk, including early consideration for further intervention. CLASSIFICATION OF EVIDENCE: This study provides Class IV evidence that LITT is not effective in reducing SUDEP incidence in patients with DRE.


Assuntos
Epilepsia Resistente a Medicamentos , Epilepsia , Terapia a Laser , Morte Súbita Inesperada na Epilepsia , Humanos , Epilepsia/cirurgia , Epilepsia Resistente a Medicamentos/cirurgia , Convulsões/cirurgia , Lasers
18.
Clin Neurophysiol ; 146: 109-117, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36608528

RESUMO

OBJECTIVE: The association between postictal electroencephalogram (EEG) suppression (PES), autonomic dysfunction, and Sudden Unexpected Death in Epilepsy (SUDEP) remains poorly understood. We compared PES on simultaneous intracranial and scalp-EEG and evaluated the association of PES with postictal heart rate variability (HRV) and SUDEP outcome. METHODS: Convulsive seizures were analyzed in patients with drug-resistant epilepsy at 5 centers. Intracranial PES was quantified using the Hilbert transform. HRV was quantified using root mean square of successive differences of interbeat intervals, low-frequency to high-frequency power ratio, and RR-intervals. RESULTS: There were 64 seizures from 63 patients without SUDEP and 11 seizures from 6 SUDEP patients. PES occurred in 99% and 87% of seizures on intracranial-EEG and scalp-EEG, respectively. Mean PES duration in intracranial and scalp-EEG was similar. Intracranial PES was regional (<90% of channels) in 46% of seizures; scalp PES was generalized in all seizures. Generalized PES showed greater decrease in postictal parasympathetic activity than regional PES. PES duration and extent were similar between patients with and without SUDEP. CONCLUSIONS: Regional intracranial PES can be present despite scalp-EEG demonstrating generalized or no PES. Postictal autonomic dysfunction correlates with the extent of PES. SIGNIFICANCE: Intracranial-EEG demonstrates changes in autonomic regulatory networks not seen on scalp-EEG.


Assuntos
Epilepsia , Disautonomias Primárias , Morte Súbita Inesperada na Epilepsia , Humanos , Eletrocorticografia , Eletroencefalografia , Convulsões/diagnóstico , Morte Súbita/etiologia
19.
Dent Res J (Isfahan) ; 19: 32, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35669608

RESUMO

Background: Considering the studies on the effects of bleaching materials on properties of dental materials, The aims of this in vitro study were to evaluate the effects of two different concentrations of bleaching agents on flexural strength and microhardness of VITA ENAMIC. Materials and Methods: In this experimental in vitro study, 30 rectangular-shaped specimens (2 mm width × 2 mm height × 12 mm length) for flexural strength and 30 specimens (5 mm width × 5 mm length × 2 mm height) for microhardness tests were prepared from VITA ENAMIC blocks 12 × 14 × 18 mm. The specimens were polished using silicon-carbide sandpapers 400, 600, 800, 1200, 2000 under flow of water for 60 s each. The prepared samples for flexural strength and microhardness were divided into 3 subgroups (n = 10): control group (C), samples bleached using Opalescence PF 15% (B15), and samples bleached with Opalescence Xtra Boost 40% (B40). Flexural strength measurement was done using a universal testing machine, and microhardness test was done using Vickers. Data were analyzed using analysis of variance and post hoc tests and P < 0.05 was considered significant. Results: The mean microhardness values of C, B15, and B40 groups were 255.46 ± 3.02, 249.86 ± 4.18, and 235.53 ± 4.61 kgf/mm2. Opalescence PF 15% and Opalescence Xtra Boost 40% affected microhardness of ENAMIC significantly (P < 0.05). The mean flexural strength values of C, B15, and B40 groups were 155.26 ± 16.13, 142.14 ± 11.52, and 133.39 ± 16.13 MPa. A significant decrease in flexural strength was found between the C and B40 groups (P = 0.007). However, the difference between flexural strength of the C and B15 groups was not significant (P > 0.05). Conclusion: Our study showed that both concentrations of bleaching agents can affect microhardness of ENAMIC. Moreover, hydrogen peroxide 40% has a negative effect on the flexural strength of ENAMIC.

20.
Neurol Clin ; 40(4): 729-739, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36270687

RESUMO

Wearable devices and mobile health software applications have a great potential for improving epilepsy-related health outcomes and contributing to personalized medical care for persons with epilepsy. With limitations and challenges, they can be used for tracking seizure occurrence and for seizure detection, prediction, and forecasting in hospital and ambulatory settings. They can also help promote self-monitoring and self-management and thereby contribute to patient empowerment. In this review, we provide an overview of current wearable devices and mobile health software applications for epilepsy. We focus on clinically validated devices, their clinical applications, the challenges faced when using these devices in real-world settings, and how these devices may be optimized in the future.


Assuntos
Epilepsia , Telemedicina , Dispositivos Eletrônicos Vestíveis , Humanos , Epilepsia/diagnóstico , Epilepsia/terapia , Convulsões/diagnóstico , Previsões
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa