Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 167
Filtrar
Mais filtros

País/Região como assunto
Intervalo de ano de publicação
1.
Eur J Oral Sci ; 132(1): e12958, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37853653

RESUMO

This clinical trial investigated the effects of pre-application enamel moistening on the impact of a 37% carbamide peroxide whitener on tooth color changes and the influence of repositioning guide colors. Forty participants were randomly assigned to in-office tooth bleaching with either moistened enamel (experimental) or dry enamel (control). The whitener was applied for 45 min over two sessions. Tooth color was visually measured or assessed using a spectrophotometer with purple or green silicone guides. Tooth bleaching was assessed using CIE76 (ΔEab ) and CIEDE2000 (ΔE00 ) formulas and by whitening and bleaching index score changes. Moistening the enamel did not significantly affect tooth color. However, the guide color choice only impacted tooth color when measured instrumentally. At baseline, the green guide resulted in statistically significantly whiter teeth than the purple guide. Less pronounced differences in the b* coordinate between baseline and final measurements were found using the green guide. The green guide also produced lower ΔEab values and less change in indexes. In conclusion, moistening the enamel did not significantly impact tooth color changes. However, the repositioning guide color influenced the tooth bleaching measured instrumentally, except for ΔE00 .


Assuntos
Clareadores Dentários , Clareamento Dental , Descoloração de Dente , Humanos , Clareamento Dental/métodos , Peróxidos/farmacologia , Clareadores Dentários/farmacologia , Ureia , Esmalte Dentário , Cor , Peróxido de Hidrogênio
2.
J Prosthet Dent ; 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-38228448

RESUMO

STATEMENT OF PROBLEM: Visual shade selection in dentistry may be influenced by factors that include the background color and the illuminant. PURPOSE: The purpose of this clinical study was to evaluate the influence of using a gray background and a light-correcting device on visual shade selection. MATERIAL AND METHODS: Two experienced clinicians assessed the incisor color of 30 volunteers using the VITA 3D-MASTER shade guide. Visual analyses were carried out using or not (control) a gray background, with and without (control) a light-correcting device (Smile Lite). Furthermore, the use of a polarizing filter was evaluated. Data from a clinical spectrophotometer were defined as the standard instrumental analysis. The agreement and the similarity (based on the whitening indexes of tabs) were evaluated between instrumental and visual analyses. Statistical testing was conducted through ordinal logistic regression and repeated-measures ANOVA. The Shapiro-Wilk test was used to confirm the data distribution, and homogeneity of variance was assessed with the Levene test (α=.05) RESULTS: The use of Smile Lite resulted in lighter tabs than indicated by the instrumental analysis, and the opposite was observed in its absence. The polarizing filter did not affect the results (P>.05). For similarity, the illuminant improved the results (P<.001). The gray background reduced the differences between visual and instrumental analysis only in the absence of the Smile Lite (P<.001). CONCLUSIONS: The color similarity between visual and instrumental analysis improved with the use of a light-correcting device with or without a polarization filter. A gray background was useful only without the light-correcting device.

3.
BMC Oral Health ; 24(1): 139, 2024 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-38281911

RESUMO

BACKGROUND: Light-cured resins are widely used as gingival barriers to protect the gums from highly concentrated peroxides used in tooth bleaching. The impact of barrier brand on clinical outcomes is typically considered negligible. However, there is limited evidence on the effects of different brands on operator experience, barrier adaptation, and patient comfort. OBJECTIVE: This clinical trial assessed the impact of four commercial gingival barrier brands (Opaldam, Topdam, Lysadam, and Maxdam) on operator perception, adaptation quality, and patient comfort. METHODS: Twenty-one undergraduate students placed gingival barriers in a randomized sequence using blinded syringes. Photographs of the barriers were taken from frontal and incisal perspectives. After bleaching procedures, operators rated handling features and safety using Likert scale forms. Two experienced evaluators independently assessed barrier adaptation quality on a scale from 1 (perfect) to 5 (unacceptable). The absolute risk of barrier-induced discomfort was recorded. Data were analyzed using Friedman and Chi-square tests (α = 0.05). RESULTS: Opaldam and Topdam received the highest scores in most handling features, except for removal, which was similar among all brands. No significant difference was observed in barrier adaptation quality between the evaluated brands. Discomforts were mainly reported in the upper dental arch, with Maxdam having the highest absolute risk (35% for this arch and 24% overall). CONCLUSIONS: This study suggests that gingival barrier brands can influence operator perception and patient comfort. Opaldam and Topdam were preferred by operators, but all brands demonstrated comparable adaptation quality. CLINICAL TRIAL REGISTRATION: The study was nested in a randomized clinical trial registered in the Brazilian Clinical Trials Registry under identification number RBR-9gtr9sc.


Assuntos
Sensibilidade da Dentina , Clareadores Dentários , Clareamento Dental , Dente , Humanos , Sensibilidade da Dentina/induzido quimicamente , Sensibilidade da Dentina/prevenção & controle , Sensibilidade da Dentina/tratamento farmacológico , Peróxido de Hidrogênio , Conforto do Paciente , Percepção , Clareamento Dental/efeitos adversos , Clareadores Dentários/efeitos adversos , Resultado do Tratamento
4.
Clin Oral Investig ; 27(6): 2449-2463, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37036514

RESUMO

OBJECTIVES: The present systematic review and network meta-analysis of randomized control trials (RCTs) aimed to establish whether there are evidence-based differences in the pharmacological agents used to manage sialorrhea in patients with Parkinson's disease (PD). MATERIAL AND METHODS: The authors searched the databases: MEDLINE via PubMed, EMBASE, Scopus, Web of Science, and Cochrane Library for clinical trials. Unpublished trials were searched on clinicaltrials.gov and the Brazilian Clinical Trials Registry. Means and standard deviations of changes in the salivary flow or drooling reported by participants due to the interventions were recorded. RESULTS: The authors analyzed 13 RCTs. Compared to the placebo, types A and B of the botulinum toxin effectively reduced the salivary flow and the severity or frequency of drooling. However, the network meta-analysis did not differentiate between the botulinum toxin types. Ipratropium bromide and glycopyrrolate did not differ from the placebo. Indirect evidence showed that ipratropium had similar results to those obtained with both types of botulinum toxin. The CINeMA approach estimated the quality of the evidence as very low for all comparisons. CONCLUSION: The best treatment for sialorrhea in patients with PD is not fully elucidated yet. Therefore, more well-conducted randomized clinical trials are required to increase the level of evidence. CLINICAL RELEVANCE: There needs to be more evidence defining the best intervention to treat sialorrhea in patients with PD. However, botulinum toxin types A and B seem to reduce sialorrhea in patients effectively.


Assuntos
Toxinas Botulínicas Tipo A , Doença de Parkinson , Sialorreia , Humanos , Sialorreia/tratamento farmacológico , Sialorreia/etiologia , Doença de Parkinson/complicações , Doença de Parkinson/tratamento farmacológico , Metanálise em Rede , Toxinas Botulínicas Tipo A/uso terapêutico , Glicopirrolato/uso terapêutico
5.
Clin Oral Investig ; 27(6): 2565-2572, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36454357

RESUMO

OBJECTIVE: This study evaluated the effect of the supplementary use of the XP-endo Finisher on postoperative endodontic pain. METHODS: This study was a randomized clinical trial with a parallel design. Ninety-two posterior teeth with necrotic pulps and apical periodontitis were instrumented with a single file (Reciproc) in a reciprocating movement followed or not (control) by additional instrumentation with XP-endo Finisher. Postoperative pain was assessed 24 h, 48 h, 72 h, and 7 days after the endodontic treatment (single session) using a universal pain assessment tool. The pain level was scored as absent, mild, moderate, or severe. The occurrence of sealer extrusion and flare-up was also recorded. Data on postoperative pain were analyzed through chi-square analysis, and the odds ratio was adjusted using a logistic regression model (α = 0.05). RESULTS: Similar levels and risks of postoperative pain were observed for both interventions, regardless of the assessment time. Approximately half of the participants presented any postoperative pain in the first 24 h after the endodontic treatment, and this occurrence reduced by less than 20% after 72 h. The extrusion of root filling material was observed in 36% of cases, and no participant presented flared-up. CONCLUSIONS: The supplementary use of the XP-endo Finisher file did not affect the incidence or level of postoperative pain reported after the endodontic treatment of posterior teeth with periapical lesions. CLINICAL RELEVANCE: The supplementary use of the XP-endo Finisher did not affect postoperative pain following the endodontic treatment of posterior teeth using a single-file reciprocating system. CLINICAL TRIAL REGISTRATION: The study protocol was registered in the Brazilian Clinical Trials Registry under identification number RBR-76w7cj (June 19, 2018).


Assuntos
Periodontite Periapical , Materiais Restauradores do Canal Radicular , Dente , Humanos , Preparo de Canal Radicular , Materiais Restauradores do Canal Radicular/uso terapêutico , Periodontite Periapical/cirurgia , Dor Pós-Operatória , Cavidade Pulpar
6.
Clin Oral Investig ; 27(12): 7595-7603, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37867163

RESUMO

OBJECTIVE: To evaluate the clinical relevance of using the XP-endo Finisher as a supplementary tool to improve the success of root canal treatment of posterior teeth with apical periodontitis, as assessed by 1-year follow-up. METHODS: A randomized clinical trial was conducted with 92 posterior teeth with apical periodontitis. Root canal treatment was performed using a single reciprocating file, with or without the supplementary use of the XP-endo Finisher. The status of apical periodontitis was assessed using the periapical index (PAI) at baseline and 1 year follow-up. Changes on PAI indicated that the lesions were healed, healing, or not healed. Successful treatments were defined as healed or healing lesions without clinical symptoms. Chi-square analysis and logistic regression were used for data analysis (α = 0.05). RESULTS: There was no significant difference in the distribution of healing status between the XP-endo Finisher group and the control group (p = 0.690). The success rates were also similar, with 81% in the XP-endo Finisher group and 78% in the control group. However, gender had a significant impact on success rates, with higher rates observed in females. CONCLUSIONS: The use of the XP-endo Finisher file as a supplementary tool did not affect the success rate of root canal treatment in posterior teeth with apical periodontitis. The findings indicate that the XP-endo Finisher file has limited clinical relevance in improving treatment outcomes for root canal treatment in posterior teeth with apical periodontitis. CLINICAL TRIAL REGISTRATION: The study protocol was registered in the Brazilian Clinical Trials Registry under identification number RBR-76w7cj (June 19, 2018).


Assuntos
Periodontite Periapical , Materiais Restauradores do Canal Radicular , Feminino , Humanos , Cavidade Pulpar , Seguimentos , Periodontite Periapical/terapia , Preparo de Canal Radicular , Masculino
7.
J Esthet Restor Dent ; 35(8): 1279-1285, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37435810

RESUMO

OBJECTIVE: This study assessed how the distance from the composite interface and the underlying chromatic substrate affect the color adjustment potential (CAP) of two single-shade composites. MATERIALS AND METHODS: Cylinder-shaped specimens were created using Vittra APS Unique (VU), Charisma Diamond One (DO), and a shaded (A3) composite. Some single-shade specimens were surrounded by the A3 composite, forming dual specimens. Color measurements of simple specimens were taken against a gray background using a spectrophotometer. All specimens were positioned at a 45° angle in a viewing booth under illuminant D65, and images were captured with a DSLR camera against gray or A3 backgrounds. Image colors were measured using image processing software and converted to CIELAB coordinates. Color differences (ΔE00 ) between the single-shade composites and the A3 composite were calculated. CAP was determined by comparing data from simple and dual specimens. RESULTS: No clinically significant differences were observed between color measurements obtained from images and the spectrophotometer. CAP was higher for DO compared to VU and increased as the distance from the composite interface decreased and when specimens were positioned against an A3 background. CONCLUSION: The color adjustment potential increased with decreased distance from the composite interface and against a chromatic background. CLINICAL SIGNIFICANCE: Achieving satisfactory color match in restorations using single-shade composites is crucial, and selecting an appropriate underlying substrate is essential. The color adjustment gradually decreases from the restoration margins towards its center.


Assuntos
Resinas Compostas , Cor , Espectrofotometria , Teste de Materiais
8.
Clin Oral Investig ; 26(8): 5105-5116, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35618962

RESUMO

AIM: To evaluate the influence of root canal filling quality on periapical lesion status using cone-beam computed tomography (CBCT). MATERIALS AND METHODS: The bibliographic search was conducted in electronic databases of PubMed, Embase, Scopus, and Web of Science without restrictions related to the year of publication and language. Inclusion criteria were prospective or retrospective cohort studies that followed periapical pathosis for, at least, 1 year. Three reviewers independently evaluated the eligibility for inclusion, extracted data, and assessed the risk of bias. The quality of the studies was based on the Newcastle-Ottawa Scale. This meta-analysis was performed to evaluate the quality of treatment by the homogeneity and apical extension of the filling. RESULTS: Of the 1179 studies initially recovered, six cohort studies were included, out of which four were considered with a low risk of bias. The results showed that the absence of gaps in the filling reduced the chance of unhealed periapical lesions by 2.39 times (RR = 2.39; 95% CI: 1.62-3.53; p < 0.00001; I2 = 55%). An apical filling extension of 0-2 mm below the apex also contributed significantly to the absence of unhealed periapical lesions (RR = 1.49; 95% CI: 1.15-1.94; p = 0.003; I2 = 2%). CONCLUSION: The homogeneity and apical extension of the filling influenced the presence of unhealed periapical lesions in endodontically treated teeth evaluated using CBCT. CLINICAL RELEVANCE: Apical extension of the filling ranging between 0 and 2 mm short of the apical foramen and the homogeneity of the filling without gaps are directly related to the success rate of root canal treatment.


Assuntos
Cavidade Pulpar , Periodontite Periapical , Tomografia Computadorizada de Feixe Cônico/métodos , Humanos , Periodontite Periapical/terapia , Estudos Prospectivos , Estudos Retrospectivos , Tratamento do Canal Radicular/métodos
9.
J Esthet Restor Dent ; 33(2): 262-268, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32955789

RESUMO

OBJECTIVE: This in-vitro study evaluated the color changes in enamel and dentin bleached in the presence of an orthodontic bracket, as well as the heterogeneity of the color and contribution of each tissue to the color change (CTCC). MATERIALS AND METHODS: Enamel-dentin specimens from extracted bovine teeth were bleached before or after bracket removal or maintained without any treatment (control). The colors of the dentin and enamel were measured individually and after recombining these substrates. The changes in the color (ΔE00 ) and whitening index (ΔWID) were estimated by the color difference between the bleached specimens and those of the control. The CTCC was also calculated by recombining the tissues from different treatments. Images of specimens obtained from a stereomicroscope were used to analyze the color homogeneity within each tissue. RESULTS: The highest values of ΔE00 and ΔWID were observed in the specimens bleached in the absence of a bracket. Bleaching in the presence of a bracket resulted in enamel with a center that was whiter than the periphery. Dentin and enamel presented similar CTCC values. CONCLUSIONS: Tooth bleaching performed in the presence of a metallic bracket resulted in a reduced bleaching effect and increased color heterogeneity within both tissues. CLINICAL SIGNIFICANCE: Tooth bleaching before the orthodontic bracket removal reduces the bleaching effect in both dentin and enamel. Moreover, a heterogeneous color of enamel surface can be observed after tooth bleaching in the presence of a nickel-free metallic orthodontic bracket.


Assuntos
Braquetes Ortodônticos , Clareamento Dental , Animais , Bovinos , Cor , Esmalte Dentário , Dentina , Peróxido de Hidrogênio
10.
Clin Oral Investig ; 24(7): 2247-2257, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31650315

RESUMO

OBJECTIVES: To compare the root filling quality, the sealer extrusion, and the healing rates of apical lesions addressed via two endodontic treatment approaches. The hypothesis tested was that both techniques present similar apical periodontitis healing results. MATERIALS AND METHODS: This study was a parallel-design, pragmatic, and randomized clinical trial. One hundred twenty anterior teeth with necrotic pulps and apical periodontitis were randomly allocated to be either instrumented with hand files and obturated with the lateral compaction technique or instrumented with a single file in a reciprocating movement and obturated with a single-cone technique. The root canal filling quality, the occurrence of sealer extrusion, and apical periodontitis healing were the outcomes of interest. Data were analyzed through chi-square analysis, and the odds ratio for healing was adjusted using a logistic regression model (α = 0.05). RESULTS: No significant differences were observed between the endodontic techniques regarding the root filling quality or sealer extrusion. Six months after treatment, both endodontic techniques presented equivalent results regarding apical periodontitis healing. The healing rate was affected only by the periapical status at baseline. CONCLUSIONS: The obturation of the root canal of the anterior teeth using reciprocating file-matched single cones presented a similar quality to that obtained with manual instrumentation followed by the lateral condensation technique. Similar healing rates of apical lesions were also observed. CLINICAL RELEVANCE: For treating anterior teeth with apical periodontitis, a reciprocating single-file, single-treatment protocol was as effective as a traditional protocol combining hand instrumentation and the lateral compaction obturation technique.


Assuntos
Periodontite Periapical , Materiais Restauradores do Canal Radicular , Preparo de Canal Radicular , Humanos , Periodontite Periapical/terapia , Obturação do Canal Radicular , Tratamento do Canal Radicular
11.
Clin Oral Investig ; 23(3): 1023-1030, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29934799

RESUMO

OBJECTIVE: To investigate whether patients' skin color could exert an influence on the dentist's decision-making for treatment, in four different cities in Brazil. MATERIAL AND METHODS: Lists of dentists were obtained and the sample selection was performed systematically. Two questionnaires were produced for the same clinical case, but the images were digitally manipulated to obtain a patient with a black and a white skin color. Dentists were free to choose treatment without any restrictions, including the financial aspects. A random sequence (white or black) was generated which was placed at random in sealed, opaque envelopes. Dentists were questioned about the decision on the treatment of a severely decayed tooth and an ill-adapted amalgam restoration. RESULTS: A total of 636 dentists agreed to participate in the study. After adjustments (multinomial logistic regression), it was observed that the black patient with a decayed tooth had a 50% lower risk of being referred for prosthetic treatment (p = 0.023) and a 99% higher risk of receiving a composite resin restoration, compared to the white patient (p = 0.027). No differences were observed regarding recommendation for tooth extraction (p = 0.657). In relation to an ill-adapted amalgam, the black patient had less risk of receiving a referral replacement with composite resin (0.09 95%CI [0.01-0.82]) and finishing and polishing (0.11 5%CI [0.01-0.99]) compared with the white patient. CONCLUSION: Patient skin color influenced the dentist's choice of treatment. In general, black patients receive referrals for cheaper, simpler procedures. CLINICAL SIGNIFICANCE: Skin color played an important role in dentists' treatment decisions. Professionals may contribute unconsciously to the propagation and replication of racial discrimination.


Assuntos
Tomada de Decisão Clínica , Brasil , Restauração Dentária Permanente , Odontólogos , Humanos , Padrões de Prática Odontológica , Pigmentação da Pele , Inquéritos e Questionários
12.
J Esthet Restor Dent ; 30(5): 427-433, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29607618

RESUMO

OBJECTIVE: This study evaluated the effects of adhesive type used as modeling liquid on the stability of the color and opacity of composites submitted to thermal cycling in staining solutions followed by a bleaching procedure. METHODS: Thirty cylinder-shaped composite specimens (10 mm diameter × 1.5 mm thickness) were built using or not using (control) an adhesive (Adper Universal or Scotchbond Multipurpose) as the modeling liquid. After polishing procedures, the color and opacity were measured, and the specimens were submitted to 200 thermal cycles with 10 s of dwell time in baths of grape juice at 5°C, water at 37°C, and coffee at 55°C. Changes in opacity and color caused by the staining solutions were measured. Then, the specimens were bleached with 35% hydrogen peroxide for 45 minutes followed by color/opacity measurements. Data were analyzed by ANOVA and Tukey's test (α = 0.05). RESULTS: The use of modeling liquids did not affect the initial color and opacity of composite. Reduced changes to color (E00 = 3.44) and opacity (+2.67%) were observed for specimens modeled using Adper Universal. Bleaching procedures reduced the color (E00 = 1.9-3.8) and opacity (-2.3 to 3.1%) alterations caused by staining solutions but were unable to restore the values observed at baseline. CONCLUSION: The use of universal adhesive as modeling liquid significantly reduced the color and opacity changes caused by staining solutions, and the bleaching procedure partially re-established the opacity and color of the composites. CLINICAL SIGNIFICANCE: This study evaluates whether using adhesive systems for modeling a composite affects the color and opacity changes caused by staining solutions followed by a bleaching procedure. The findings suggest that the use of a universal adhesive as modeling liquid can reduce the alterations in optical properties caused by staining solutions, and the application of high-concentrated hydrogen peroxide over the composite reduce the color changes without fully recover the initial color.


Assuntos
Resinas Compostas , Cimentos Dentários , Cor , Peróxido de Hidrogênio , Teste de Materiais , Propriedades de Superfície
13.
J Adhes Dent ; 19(1): 49-57, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28195276

RESUMO

PURPOSE: To determine whether an experimental thermally deposited siloxane-methacrylate coating for use in industrial scale applications would improve the bond strength of resin-based materials to glass fiber posts (GFPs) without affecting their mechanical properties. MATERIALS AND METHODS: An experimental 5% (w/v) solution of methacryloxypropyltrimethoxysilane was prepared. Two types of GFPs (Exacto, Angelus; White Post DC, FGM) were divided into the following groups: S: silane; SA: silane and adhesive; HS: 35% H2O2 and silane; HSA: 35% H2O2, silane and adhesive; Exp: siloxane-methacrylate coating (Si-O) via post immersion in experimental solution followed by heating; Exp-S: silane after Si-O treatment; Exp-A: adhesive after Si-O treatment; and Exp-SA: silane and adhesive after Si-O treatment. The posts were positioned in a mold to allow insertion of a dual-curing resin core, serially sectioned into beams, and subjected to microtensile bond strength (µTSB) testing. The three-point bending test and SEM/EDX analysis were used to assess the mechanical and surface properties of untreated GFPs that were etched with H2O2 or treated with Si-O. RESULTS: Surface treatments affected the µTSB only for the Exacto GFPs. The highest µTBS (MPa) was observed in Exp-S and Exp-SA groups, whereas H2O2 etching resulted in intermediate values. The mechanical properties were not affected by surface treatments. Exacto GFPs had significantly higher flexural strength (σf) and flexural modulus (Ef) than did the White Post DC GFPs, but the latter were significantly stiffer (S) than Exacto, regardless of the surface treatment tested. H2O2 promoted morphological changes in post surfaces. The experimental treatment promoted deposition of Si onto the post surface, improving bond strengths of Exacto posts. CONCLUSION: The proposed novel coating technique is a viable procedure for fiber post manufacturers to improve the µTSB of resin-based materials.


Assuntos
Colagem Dentária , Vidro , Metacrilatos , Técnica para Retentor Intrarradicular , Silanos , Teste de Materiais , Propriedades de Superfície
14.
J Prosthet Dent ; 118(5): 631-636, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28385443

RESUMO

STATEMENT OF PROBLEM: The cementation of ceramic veneers using light-polymerized resin cement is largely dependent on the proper light activation of the cement. Light activation using high irradiance could shorten the time required to lute multiple restorations. PURPOSE: The purpose of this in vitro study was to evaluate the light transmission of dental light-polymerizing units through ceramic cylinders and its effect on the polymerization kinetics of a resin cement. MATERIAL AND METHODS: Ceramic ingots (IPS Empress Esthetic, shade ET1) were sectioned to produce cylinders 0.5, 1.0, and 2.0 mm thick. Two light-emitting diode units were evaluated: SmartLite Focus and Valo Cordless, the latter used in either Standard or Xtra Power (XP) modes. Light transmission (average of irradiance, total energy, and light-emission profile) through the cylinders was measured (n=3). The polymerization kinetics of a resin cement light polymerized through the ceramic was monitored for 5 minutes (n=3). The degree of conversion was measured again after 72 hours. Data were individually analyzed with 2-way ANOVA and the Tukey HSD test (α=.05). RESULTS: Valo at XP presented the highest values of irradiance and SmartLite the lowest, irrespective of the ceramic thickness. Regarding the total energy, XP showed the lowest values. The total energy and irradiance lessened with the increase in ceramic thickness. In general, except for Valo at XP, the ceramic thickness did not affect the degree of conversion. Valo at XP and interposing 2.0 mm ceramic resulted in the lowest values of Rpmax. CONCLUSIONS: The reduction of total energy and irradiance by ceramic interposition had only a slight effect on polymerization kinetics.


Assuntos
Cerâmica/uso terapêutico , Cura Luminosa de Adesivos Dentários/métodos , Cimentos de Resina/uso terapêutico , Humanos , Técnicas In Vitro , Cura Luminosa de Adesivos Dentários/instrumentação , Polimerização/efeitos da radiação
15.
Am J Orthod Dentofacial Orthop ; 151(5): 949-956, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28457273

RESUMO

INTRODUCTION: In this study, we evaluated the caries inhibition and shear bond strength achieved with the addition of the antibacterial monomer [2-(Methacryloyloxy)ethyl] trimethylammonium chloride (MADQUAT) to an adhesive used to bond orthodontic brackets. METHODS: Experimental adhesives were formulated with addition of 0% (control), 5%, or 10% MADQUAT followed by measurement of the degree of conversion. These adhesives were used to lute brackets to the enamel of premolars (n = 30). Biofilm from a microcosm model was cultivated in half of the specimens under cariogenic challenge for 5 days. The brackets were subjected to a shear bond strength test followed by measurement of the internal hardness of the enamel around the brackets to calculate the integrated mineral loss. RESULTS: The addition of MADQUAT slightly increased the degree of conversion. Adhesive containing 10% MADQUAT significantly reduced the integrated mineral loss around the bracket but also resulted in the lowest values of bond strength. No effects on bond strength and integrated mineral loss were observed with the addition of 5% MADQUAT to the adhesive. The cariogenic challenge did not affect the bond strength and the failure mode. CONCLUSIONS: MADQUAT was effective to reduce the integrated mineral loss only when added to the adhesive at a concentration of 10% despite the reduction of bond strength.


Assuntos
Colagem Dentária/métodos , Cárie Dentária/prevenção & controle , Cimentos Dentários/uso terapêutico , Metacrilatos/uso terapêutico , Braquetes Ortodônticos , Antibacterianos/uso terapêutico , Biofilmes/crescimento & desenvolvimento , Colagem Dentária/efeitos adversos , Análise do Estresse Dentário , Humanos , Técnicas In Vitro , Braquetes Ortodônticos/efeitos adversos
16.
J Adhes Dent ; 18(4): 349-54, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27419245

RESUMO

PURPOSE: To evaluate the effect of chlorhexidine or glutaraldehyde pretreatment on the bonding stability of selfetching and etch-and-rinse adhesives to bleached dentin. MATERIALS AND METHODS: The occlusal surface of 80 third molars was abraded to expose a flat mid-dentin surface, which was then subjected to a bleaching procedure using 20% hydrogen peroxide and sodium perborate for 14 days. Afterwards, the specimens were kept in distilled water, followed by application of either a three-step etchand- rinse (Adper Scotchbond Multi-Purpose Plus, SBMP) or a two-step self-etching (Clearfil SE Bond, CSE) adhesive system. For each approach, the bleached dentin was treated with chlorhexidine or glutaraldehyde, or left untreated, prior to the adhesive procedure. Unbleached dentin was used as a control. Composite cylinders were built up over the adhesive-covered dentin followed by parallel sectioning of specimens to obtain 1-mm slices. The slices were trimmed to obtain hourglass-shaped specimens with approximately 1.0 mm2 of bonding interface. Half of the specimens were subjected to microtensile bond strength (µTBS) testing after 24 h, while the other half were stored in distilled water for 3 months prior to the µTBS test. The mode of failure was analyzed using optical microscopy. RESULTS: For the SBMP protocol, the highest µTBS was achieved with glutaraldehyde-treated dentin, and the same µTBS values were maintained after 3 months of storage. For the CSE protocol, the highest µTBS was obtained with chlorhexidine-treated dentin. CONCLUSION: Glutaraldehyde and chlorhexidine pretreatment should be considered to improve the µTBS of adhesives to bleached dentin, while the pretreatment effect was adhesive dependent.


Assuntos
Condicionamento Ácido do Dente/métodos , Colagem Dentária , Dentina/ultraestrutura , Cimentos de Resina/química , Clareadores Dentários/química , Clareamento Dental/métodos , Boratos/química , Boratos/farmacologia , Clorexidina/química , Clorexidina/farmacologia , Resinas Compostas/química , Reagentes de Ligações Cruzadas/química , Reagentes de Ligações Cruzadas/farmacologia , Materiais Dentários/química , Dentina/efeitos dos fármacos , Glutaral/química , Glutaral/farmacologia , Humanos , Peróxido de Hidrogênio/química , Peróxido de Hidrogênio/farmacologia , Teste de Materiais , Inibidores de Metaloproteinases de Matriz/química , Inibidores de Metaloproteinases de Matriz/farmacologia , Estresse Mecânico , Resistência à Tração , Fatores de Tempo , Clareadores Dentários/farmacologia , Água/química
17.
Clin Oral Investig ; 19(5): 1047-53, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25323985

RESUMO

OBJECTIVES: This study was designed to adapt a previously developed in vitro microcosm biofilm model to create carries-affected dentin (CAD) and establish conditions for using the model in bonding studies. MATERIALS AND METHODS: Biofilms were originated from human saliva and grown on dentin discs for 0 (sound dentin), 3, 5, 7, 14, or 21 days under intermittent cariogenic condition (n = 10). At each time point, composite cylinders were bonded to the dentin using self-etch adhesive (Clearfil SE Bond). The response variables were integrated mineral loss (ΔS), lesion depth (LD), shear bond strength (SBS), and failure mode. Data were statistically analyzed (α = 0.05). Bonded interfaces were analyzed by scanning electron microscopy (SEM), and dentin surfaces characterized by infrared spectroscopy (Fourier transform infrared spectroscopy, FTIR). RESULTS: Lower ΔS was found for sound dentin than for CAD in all experimental groups, except for the group under cariogenic challenge for 3 days. The SBS to CAD was significantly lower than control for all cariogenic challenge times. Adhesive failures were predominant in all groups. ΔS and LD had a significant negative correlation with SBS. A significant exponential decay in SBS was associated with increased ΔS values. CAD had lower mineral and amide I content and an irregular hybridization interface compared to sound dentin. CONCLUSIONS: The microcosm biofilm model was able to artificially induce CAD, which imposed challenge to the bonding of the polymeric adhesive material. CLINICAL RELEVANCE: Presence of CAD might interfere with the bonding of polymeric materials. The microcosm biofilm model proposed could be useful for preclinical dentin bonding studies.


Assuntos
Biofilmes , Colagem Dentária , Cárie Dentária/microbiologia , Falha de Restauração Dentária , Adesivos Dentinários/química , Humanos , Técnicas In Vitro , Teste de Materiais , Microscopia Eletrônica de Varredura , Cimentos de Resina , Espectroscopia de Infravermelho com Transformada de Fourier , Propriedades de Superfície , Desmineralização do Dente
18.
Braz Oral Res ; 38: e032, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38747819

RESUMO

This study assessed the reliability of a color measurement method using images obtained from a charge-coupled device (CCD) camera and a stereoscopic loupe. Disc-shaped specimens were created using the composite Filtek Z350 XT (shades DA1, DA2, DA3, and DA4) (n = 3). CIELAB color coordinates of the specimens were measured using the spectrophotometer SP60 over white and black backgrounds. Images of the same specimens were taken using a CCD camera attached to a stereoscopic loupe. The color of the image was measured (red-green-blue [RGB]) using an image processing software and converted to CIELAB coordinates. For each color coordinate, data from images were adjusted using linear regressions predicting those values from SP60. The whiteness index for dentistry (WID) and translucency parameter (TP00) of the specimens as well as the color differences (ΔE00) among pairwise shades were calculated. Data were analyzed via repeated-measures analysis of variance and Tukey's post hoc test (α = 0.05). Images obtained using the loupe tended to be darker and redder than the actual color. Data adjustment resulted in similar WID, ΔE00, and TP00 values to those observed for the spectrophotometer. Differences were observed only for the WID of shade DA3 and ΔE00 for comparing DA1 and DA3 over the black background. However, these differences were not clinically relevant. The use of adjusted data from images taken using a stereoscopic loupe is considered a feasible method for color measurement.


Assuntos
Cor , Colorimetria , Resinas Compostas , Teste de Materiais , Espectrofotometria , Reprodutibilidade dos Testes , Resinas Compostas/química , Espectrofotometria/métodos , Colorimetria/métodos , Colorimetria/instrumentação , Análise de Variância , Valores de Referência , Modelos Lineares , Processamento de Imagem Assistida por Computador/métodos
19.
Restor Dent Endod ; 49(1): e7, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38449498

RESUMO

Objectives: This study aimed to evaluate the impact of substrate color and interface distance on the color adjustment of 2 single-shade composites, Vittra APS Unique and Charisma Diamond One. Materials and Methods: Dual disc-shaped specimens were created using Vittra APS Unique or Charisma Diamond One as the center composite, surrounded by shaded composites (A1 or A3). Color measurements were taken with a spectrophotometer against a gray background, recording the color coordinates in the CIELAB color space. Illumination with a light-correcting device and image acquisition using a polarizing filter-equipped cell phone were performed on specimens over the same background. Image processing software was used to measure the color coordinates in the center and periphery of the inner composite and in the outer composite. The color data were then converted to CIELAB coordinates and adjusted using data from the spectrophotometer. Color differences (ΔE00) between the center/periphery of single-shade and outer composites were calculated, along with color changes in single-shade composites caused by different outer composites. Color differences for the inner composites surrounded by A1 and A3 were also calculated. Data were analyzed using repeated-measures analysis of variance (α = 0.05). Results: The results showed that color discrepancies were lowest near the interface and when the outer composite was whiter (A1). Additionally, Charisma Diamond One exhibited better color adjustment ability than Vittra APS Unique. Conclusions: Color discrepancies between the investigated single-shade composites diminished towards the interface with the surrounding composite, particularly when the latter exhibited a lighter shade.

20.
J Appl Oral Sci ; 32: e20230348, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38537029

RESUMO

BACKGROUND: Repositioning guides are commonly employed in clinical studies to ensure consistent tooth color measurements. Yet, their influence on measured color remains uncertain. OBJECTIVE: This study evaluated the impact of repositioning guides' color and usage on tooth color measurement using a clinical spectrophotometer. METHODOLOGY: In total, 18 volunteers participated in this study, in which the color of their upper left central incisor and upper left canine was measured with or without repositioning guides (control). The guides were made from pink, blue, or translucent silicone, as well as an acetate-based bleaching tray. Tooth color was measured in triplicates using a clinical spectrophotometer based on the CIELAB system. The standard deviations of these readings were used to estimate reproducibility, and color differences (ΔE00) between the measurements with guides and the control were calculated. RESULTS: Repositioning guides had a minimal effect on L* values and no effect on b* values. The use of pink silicone increased a* values, whereas blue or translucent silicone reduced them. Irrespective of the evaluated tooth, the lowest ΔE00 values were observed for the translucent silicone and bleaching tray. The usage of guides only affected data variability for the L* color coordinate. CONCLUSION: Using repositioning guides can significantly impact the precision of tooth color measurement with a clinical spectrophotometer.


Assuntos
Incisivo , Clareamento Dental , Humanos , Cor , Reprodutibilidade dos Testes , Espectrofotometria , Silicones
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa