Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Acta Oncol ; 62(8): 923-931, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37488951

RESUMO

Background: Delivered radiotherapy doses do not exactly match those planned for a course of treatment, largely due to inter-fraction changes in anatomy. In this study, accumulated delivered dose was calculated for a sample of cervical cancer patients, by deformably registering daily cone beam computed tomography (CBCT) images to the planning computed tomography (CT) scan. Planned and accumulated doses were compared for the clinical target volume (CTV), bladder, and rectum.Material and Methods: For 10 patients receiving 45 Gy in 25 fractions of external beam radiotherapy, daily dose distributions were calculated on CBCT. These images were deformed onto the planning CT and the dose was accumulated using Velocity 4.1 (Varian Medical Systems, Palo Alto, USA). The quality of deformable image registration was evaluated visually and by calculating Dice similarity coefficients and mean distance to agreement.Results: V95%>99% was achieved for the primary CTV in 9/10 patients for the planned dose distribution and 7/10 patients for the accumulated dose distribution. Primary CTV coverage by 95% of the prescription dose was reduced in one patient, due to an increase in anterior-posterior separation. Comparison of planned and accumulated dose volume histograms (DVHs) for the bladder and rectum found agreement within 5% at low and intermediate doses, but differences exceeded 20% at higher doses. Direct addition of CBCT DVHs was seen to be a poor estimate for the accumulated DVH at higher doses.Conclusion: Computation of delivered radiotherapy dose that accounts for inter-fraction anatomical changes is important for establishing dose-effect relationships. Updating delivered dose distributions after each fraction would support informed clinical decision making on any potential treatment interventions.


Assuntos
Radioterapia de Intensidade Modulada , Tomografia Computadorizada de Feixe Cônico Espiral , Neoplasias do Colo do Útero , Feminino , Humanos , Neoplasias do Colo do Útero/diagnóstico por imagem , Neoplasias do Colo do Útero/radioterapia , Dosagem Radioterapêutica , Tomografia Computadorizada de Feixe Cônico/métodos , Tomografia Computadorizada por Raios X , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos
2.
Radiat Oncol ; 17(1): 9, 2022 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-35039065

RESUMO

INTRODUCTION: Acute and late toxicity was analysed for prostate cancer patients with bilateral hip prostheses, who received fixed field intensity modulated radiotherapy (IMRT). The aims were (1) to establish whether toxicity rates differed from those of a control group with normal hips, (2) to develop a volumetric modulated arc therapy (VMAT) approach for patients with prostheses and (3) to compare doses to bladder and rectum for the control group, prostheses group and VMAT replans for the prostheses group. METHODS: Genitourinary (GU) and gastrointestinal (GI) toxicity was scored using Common Terminology Criteria for Adverse Events version 5.0. The incidence of grade 2 or worse (G2+) toxicity was compared using Fisher's exact test. Dose volume histograms (DVHs) and mean doses to organs at risk (OARs) were compared using signed rank tests. RESULTS: There were 17 patients in the prostheses group and 50 in the control group. Acute and late GU toxicity was similar. G2+ late GI toxicity incidence was 31% for the prostheses group and 14% for the control group (p = 0.14). Significant differences (p < 0.05) were seen between the OAR DVHs of the prostheses group who had IMRT and the control group for a range of intermediate doses. The rectum mean dose was significantly different (p < 0.001), but no difference was seen for the bladder mean dose (p = 0.08). CONCLUSIONS: No significant differences were seen in GU and GI toxicity incidence between patients with bilateral hip prostheses and a control group. The DVHs for bladder and rectum were significantly higher for patients with prostheses planned with IMRT. Replanning using a VMAT technique significantly reduced doses to the OARs, whilst maintaining good planning target volume coverage.


Assuntos
Gastroenteropatias/etiologia , Prótese de Quadril , Complicações Pós-Operatórias/etiologia , Neoplasias da Próstata/radioterapia , Lesões por Radiação/etiologia , Radioterapia de Intensidade Modulada/efeitos adversos , Doenças Urogenitais/etiologia , Idoso , Idoso de 80 Anos ou mais , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
3.
Phys Rev Lett ; 102(9): 096405, 2009 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-19392542

RESUMO

We study analytically the optical properties of a simple model for an electron-hole pair on a ring subjected to perpendicular magnetic flux and in-plane electric field. We show how to tune this excitonic system from optically active to optically dark as a function of these external fields. Our results offer a simple mechanism for exciton storage and readout.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa