Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Eur Radiol ; 27(5): 1954-1962, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-27553931

RESUMO

OBJECTIVES: To evaluate the feasibility of performing comprehensive Cardiac Magnetic resonance (CMR) guided electrophysiological (EP) interventions in a porcine model encompassing left atrial access. METHODS: After introduction of two femoral sheaths 14 swine (41 ± 3.6 kg) were transferred to a 1.5 T MR scanner. A three-dimensional whole-heart sequence was acquired followed by segmentation and the visualization of all heart chambers using an image-guidance platform. Two MR conditional catheters were inserted. The interventional protocol consisted of intubation of the coronary sinus, activation mapping, transseptal left atrial access (n = 4), generation of ablation lesions and eventually ablation of the atrioventricular (AV) node. For visualization of the catheter tip active tracking was used. Catheter positions were confirmed by passive real-time imaging. RESULTS: Total procedure time was 169 ± 51 minutes. The protocol could be completed in 12 swine. Two swine died from AV-ablation induced ventricular fibrillation. Catheters could be visualized and navigated under active tracking almost exclusively. The position of the catheter tips as visualized by active tracking could reliably be confirmed with passive catheter imaging. CONCLUSIONS: Comprehensive CMR-guided EP interventions including left atrial access are feasible in swine using active catheter tracking. KEY POINTS: • Comprehensive CMR-guided electrophysiological interventions including LA access were conducted in swine. • Active catheter-tracking allows efficient catheter navigation also in a transseptal approach. • More MR-conditional tools are needed to facilitate left atrial interventions in humans.


Assuntos
Técnicas Eletrofisiológicas Cardíacas/métodos , Imagem por Ressonância Magnética Intervencionista/métodos , Animais , Catéteres , Átrios do Coração , Imageamento por Ressonância Magnética/métodos , Suínos
2.
Europace ; 18(4): 572-7, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26316146

RESUMO

AIMS: Recently cardiac magnetic resonance (CMR) imaging has been found feasible for the visualization of the underlying substrate for cardiac arrhythmias as well as for the visualization of cardiac catheters for diagnostic and ablation procedures. Real-time CMR-guided cavotricuspid isthmus ablation was performed in a series of six patients using a combination of active catheter tracking and catheter visualization using real-time MR imaging. METHODS AND RESULTS: Cardiac magnetic resonance utilizing a 1.5 T system was performed in patients under deep propofol sedation. A three-dimensional-whole-heart sequence with navigator technique and a fast automated segmentation algorithm was used for online segmentation of all cardiac chambers, which were thereafter displayed on a dedicated image guidance platform. In three out of six patients complete isthmus block could be achieved in the MR scanner, two of these patients did not need any additional fluoroscopy. In the first patient technical issues called for a completion of the procedure in a conventional laboratory, in another two patients the isthmus was partially blocked by magnetic resonance imaging (MRI)-guided ablation. The mean procedural time for the MR procedure was 109 ± 58 min. The intubation of the CS was performed within a mean time of 2.75 ± 2.21 min. Total fluoroscopy time for completion of the isthmus block ranged from 0 to 7.5 min. CONCLUSION: The combination of active catheter tracking and passive real-time visualization in CMR-guided electrophysiologic (EP) studies using advanced interventional hardware and software was safe and enabled efficient navigation, mapping, and ablation. These cases demonstrate significant progress in the development of MR-guided EP procedures.


Assuntos
Flutter Atrial/cirurgia , Função do Átrio Direito , Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos , Ablação por Cateter/instrumentação , Átrios do Coração/cirurgia , Imagem por Ressonância Magnética Intervencionista , Adulto , Idoso , Algoritmos , Flutter Atrial/diagnóstico por imagem , Flutter Atrial/fisiopatologia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Sedação Profunda/métodos , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Desenho de Equipamento , Fluoroscopia , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/fisiopatologia , Humanos , Hipnóticos e Sedativos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Valor Preditivo dos Testes , Propofol , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa