Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Circulation ; 148(1): 35-46, 2023 07 04.
Artigo em Inglês | MEDLINE | ID: mdl-37199171

RESUMO

BACKGROUND: Pulsed field ablation is a novel nonthermal cardiac ablation modality using ultra-rapid electrical pulses to cause cell death by a mechanism of irreversible electroporation. Unlike the traditional ablation energy sources, pulsed field ablation has demonstrated significant preferentiality to myocardial tissue ablation, and thus avoids certain thermally mediated complications. However, its safety and effectiveness remain unknown in usual clinical care. METHODS: MANIFEST-PF (Multi-National Survey on the Methods, Efficacy, and Safety on the Post-Approval Clinical Use of Pulsed Field Ablation) is a retrospective, multinational, patient-level registry wherein patients at each center were prospectively included in their respective center registries. The registry included all patients undergoing postapproval treatment with a multielectrode 5-spline pulsed field ablation catheter to treat atrial fibrillation (AF) between March 1, 2021, and May 30, 2022. The primary effectiveness outcome was freedom from clinical documented atrial arrhythmia (AF/atrial flutter/atrial tachycardia) of ≥30 seconds on the basis of electrocardiographic data after a 3-month blanking period (on or off antiarrhythmic drugs). Safety outcomes included the composite of acute (<7 days postprocedure) and latent (>7 days) major adverse events. RESULTS: At 24 European centers (77 operators) pulsed field ablation was performed in 1568 patients with AF: age 64.5±11.5 years, female 35%, paroxysmal/persistent AF 65%/32%, CHA2DS2-VASc 2.2±1.6, median left ventricular ejection fraction 60%, and left atrial diameter 42 mm. Pulmonary vein isolation was achieved in 99.2% of patients. After a median (interquartile range) follow-up of 367 (289-421) days, the 1-year Kaplan-Meier estimate for freedom from atrial arrhythmia was 78.1% (95% CI, 76.0%-80.0%); clinical effectiveness was more common in patients with paroxysmal AF versus persistent AF (81.6% versus 71.5%; P=0.001). Acute major adverse events occurred in 1.9% of patients. CONCLUSIONS: In this large observational registry of the postapproval clinical use of pulsed field technology to treat AF, catheter ablation using pulsed field energy was clinically effective in 78% of patients with AF.


Assuntos
Fibrilação Atrial , Flutter Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/tratamento farmacológico , Estudos Retrospectivos , Volume Sistólico , Função Ventricular Esquerda , Resultado do Tratamento , Flutter Atrial/etiologia , Sistema de Registros , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva
2.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38584468

RESUMO

AIMS: Pulsed field ablation (PFA) has significant advantages over conventional thermal ablation of atrial fibrillation (AF). This first-in-human, single-arm trial to treat paroxysmal AF (PAF) assessed the efficiency, safety, pulmonary vein isolation (PVI) durability and one-year clinical effectiveness of an 8 Fr, large-lattice, conformable single-shot PFA catheter together with a dedicated electroanatomical mapping system. METHODS AND RESULTS: After rendering the PV anatomy, the PFA catheter delivered monopolar, biphasic pulse trains (5-6 s per application; ∼4 applications per PV). Three waveforms were tested: PULSE1, PULSE2, and PULSE3. Follow-up included ECGs, Holters at 6 and 12 months, and symptomatic and scheduled transtelephonic monitoring. The primary and secondary efficacy endpoints were acute PVI and post-blanking atrial arrhythmia recurrence, respectively. Invasive remapping was conducted ∼75 days post-ablation. At three centres, PVI was performed by five operators in 85 patients using PULSE1 (n = 30), PULSE2 (n = 20), and PULSE3 (n = 35). Acute PVI was achieved in 100% of PVs using 3.9 ± 1.4 PFA applications per PV. Overall procedure, transpired ablation, PFA catheter dwell and fluoroscopy times were 56.5 ± 21.6, 10.0 ± 6.0, 19.1 ± 9.3, and 5.7 ± 3.9 min, respectively. No pre-defined primary safety events occurred. Upon remapping, PVI durability was 90% and 99% on a per-vein basis for the total and PULSE3 cohort, respectively. The Kaplan-Meier estimate of one-year freedom from atrial arrhythmias was 81.8% (95% CI 70.2-89.2%) for the total, and 100% (95% CI 80.6-100%) for the PULSE3 cohort. CONCLUSION: Pulmonary vein isolation (PVI) utilizing a conformable single-shot PFA catheter to treat PAF was efficient, safe, and effective, with durable lesions demonstrated upon remapping.


Assuntos
Fibrilação Atrial , Cateteres Cardíacos , Ablação por Cateter , Veias Pulmonares , Recidiva , Humanos , Veias Pulmonares/cirurgia , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Ablação por Cateter/métodos , Ablação por Cateter/instrumentação , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Resultado do Tratamento , Desenho de Equipamento , Técnicas Eletrofisiológicas Cardíacas , Fatores de Tempo , Frequência Cardíaca , Potenciais de Ação
3.
Circulation ; 146(24): 1808-1819, 2022 12 13.
Artigo em Inglês | MEDLINE | ID: mdl-36134574

RESUMO

BACKGROUND: Pulsed field ablation (PFA) has a unique safety profile when used to treat atrial fibrillation, largely related to its preferentiality for myocardial tissue ablation, in particular, esophageal sparing. A pentaspline catheter was the first such PFA system studied clinically for atrial fibrillation ablation; in these initial regulatory trials, the catheter was used for pulmonary vein isolation and left atrial posterior wall ablation. Since its regulatory approval in Europe, in clinical practice, physicians have ablated beyond pulmonary vein isolation and left atrial posterior wall ablation to expanded lesion sets in closer proximity to coronary arteries. This is an unstudied important issue because preclinical and clinical data have raised the potential for coronary arterial spasm. Herein, we studied the vasospastic potential of PFA lesion sets, both remote from and adjacent to coronary arteries. METHODS: During routine atrial fibrillation ablation using the pentaspline PFA catheter, coronary angiography was performed before, during, and after pulsed field applications. The lesion sets studied included: (1) those remote from the coronary arteries such as pulmonary vein isolation (n=25 patients) and left atrial posterior wall ablation (n=5), and (2) ablation of the cavotricuspid isthmus (n=20) that is situated adjacent to the right coronary artery. RESULTS: During pulmonary vein isolation and left atrial posterior wall ablation, coronary spasm did not occur, but cavotricuspid isthmus ablation provoked severe subtotal vasospasm in 5 of 5 (100%) consecutive patients, and this was relieved by intracoronary nitroglycerin in 5.5±3.5 minutes. ST-segment elevation was not observed. However, no patient (0%, P=0.004) had severe spasm if first administered parenteral nitroglycerin, either intracoronary (n=5) or intravenous (n=10), before treatment. CONCLUSIONS: Coronary vasospasm was not provoked during PFA at locations remote from coronary arteries, but when the energy is delivered adjacent to a coronary artery, PFA routinely provokes subclinical vasospasm. This phenomenon is attenuated by nitroglycerin, administered either post hoc to treat spasm or as prophylaxis.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/cirurgia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Ablação por Cateter/efeitos adversos , Átrios do Coração , Nitroglicerina/uso terapêutico , Resultado do Tratamento
4.
Europace ; 25(11)2023 11 02.
Artigo em Inglês | MEDLINE | ID: mdl-37956309

RESUMO

AIMS: Validating mapping systems that identify atrial fibrillation (AF) sources (focal/rotational activity) is confounded by the absence of ground truth. A key concern of prior mapping technologies is spatiotemporal instability, manifesting as poor map reproducibility. Electrographic flow (EGF) employs a novel algorithm that visualizes atrial electrical wavefront propagation to identify putative AF sources. We analysed both intra- (3 min) and inter- (>3 months) procedure EGF map reproducibility. METHODS AND RESULTS: In 23 persistent AF patients, after pulmonary vein isolation (PVI), EGF maps were generated from 3 serial 1 min recordings using a 64-electrode basket mapping catheter (triplets) at right and left atrial locations. Source prevalence from map triplets was compared between recordings. Per protocol, 12 patients returned for 3-month remapping (1 non-inducible): index procedure post-PVI EGF maps were compared with initial EGF remapping at 3-month redo. Intra-procedure reproducibility: analysing 224 map triplets (111 right atrium, 113 left atrium) revealed a high degree of map consistency with minimal min-to-min shifts: 97 triplets (43%), exact match of leading sources on all 3 maps; 95 triplets (42%), leading source within 1 electrode space on 2 of 3 maps; and 32 triplets (14%), chaotic leading source pattern. Average deviation in source prevalence over 60 s was low (6.4%). Inter-procedure reproducibility: spatiotemporal stability of EGF mapping >3 months was seen in 16 of 18 (89%) sources mapped in 12 patients with (re)inducible AF. CONCLUSION: Electrographic flow mapping generates reproducible intra- and inter-procedural maps, providing rationale for randomized clinical trials targeting these putative AF sources.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Reprodutibilidade dos Testes , Fator de Crescimento Epidérmico , Ablação por Cateter/métodos , Átrios do Coração , Veias Pulmonares/cirurgia , Resultado do Tratamento
5.
Europace ; 24(8): 1256-1266, 2022 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-35647644

RESUMO

AIMS: Pulsed field ablation (PFA) is a novel atrial fibrillation (AF) ablation modality that has demonstrated preferential tissue ablation, including no oesophageal damage, in first-in-human clinical trials. In the MANIFEST-PF survey, we investigated the 'real world' performance of the only approved PFA catheter, including acute effectiveness and safety-in particular, rare oesophageal effects and other unforeseen PFA-related complications. METHODS AND RESULTS: This retrospective survey included all 24 clinical centres using the pentaspline PFA catheter after regulatory approval. Institution-level data were obtained on patient characteristics, procedure parameters, acute efficacy, and adverse events. With an average of 73 patients treated per centre (range 7-291), full cohort included 1758 patients: mean age 61.6 years (range 19-92), female 34%, first-time ablation 94%, paroxysmal/persistent AF 58/35%. Most procedures employed deep sedation without intubation (82.1%), and 15.1% were discharged same day. Pulmonary vein isolation (PVI) was successful in 99.9% (range 98.9-100%). Procedure time was 65 min (38-215). There were no oesophageal complications or phrenic nerve injuries persisting past hospital discharge. Major complications (1.6%) were pericardial tamponade (0.97%) and stroke (0.4%); one stroke resulted in death (0.06%). Minor complications (3.9%) were primarily vascular (3.3%), but also included transient phrenic nerve paresis (0.46%), and TIA (0.11%). Rare complications included coronary artery spasm, haemoptysis, and dry cough persistent for 6 weeks (0.06% each). CONCLUSION: In a large cohort of unselected patients, PFA was efficacious for PVI, and expressed a safety profile consistent with preferential tissue ablation. However, the frequency of 'generic' catheter complications (tamponade, stroke) underscores the need for improvement.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Acidente Vascular Cerebral , Adulto , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/etiologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Feminino , Humanos , Pessoa de Meia-Idade , Veias Pulmonares/cirurgia , Estudos Retrospectivos , Acidente Vascular Cerebral/etiologia , Resultado do Tratamento , Adulto Jovem
6.
Europace ; 23(11): 1757-1766, 2021 11 08.
Artigo em Inglês | MEDLINE | ID: mdl-34151947

RESUMO

AIMS: We studied the extent/area of electrical pulmonary vein isolation (PVI) after either pulsed field ablation (PFA) using a pentaspline catheter or thermal ablation technologies. METHODS AND RESULTS: In a clinical trial (NCT03714178), paroxysmal atrial fibrillation (PAF) patients underwent PVI with a multi-electrode pentaspline PFA catheter using a biphasic waveform, and after 75 days, detailed voltage maps were created during protocol-specified remapping studies. Comparative voltage mapping data were retrospectively collected from consecutive PAF patients who (i) underwent PVI using thermal energy, (ii) underwent reablation for recurrence, and (iii) had durably isolated PVs. The left and right PV antral isolation areas and non-ablated posterior wall were quantified. There were 20 patients with durable PVI in the PFA cohort, and 39 in the thermal ablation cohort [29 radiofrequency ablation (RFA), 6 cryoballoon, and 4 visually guided laser balloon]. Pulsed field ablation patients were younger with shorter follow-up. Left atrial diameter and ventricular systolic function were preserved in both cohorts. There was no significant difference between the PFA and thermal ablation cohorts in either the left- and right-sided PV isolation areas, or the non-ablated posterior wall area. The right superior PV isolation area was smaller with PFA than RFA, but this disappeared after propensity score matching. Notch-like normal voltage areas were seen at the posterior aspect of the carina in the balloon sub-cohort, but not the PFA or RFA cohorts. CONCLUSION: Catheter-based PVI with the pentaspline PFA catheter creates chronic PV antral isolation areas as encompassing as thermal energy ablation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Criocirurgia , Humanos , Terapia a Laser , Veias Pulmonares/cirurgia , Ablação por Radiofrequência , Recidiva , Estudos Retrospectivos , Resultado do Tratamento
7.
Circ J ; 80(2): 340-5, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26632536

RESUMO

BACKGROUND: Mexiletine is often used for medical therapy in LQT3 patients, however, the usefulness of mexiletine infusion test for LQT3 patients has not been reported. The aim of this study was to evaluate the usefulness of mexiletine infusion test for detecting LQT3 patients. METHODS AND RESULTS: We analyzed response in 12-lead electrocardiogram parameters measured in II or V5 to i.v. mexiletine infusion (2 mg/kg) during sinus rhythm among 31 genotype-positive LQT patients (29 ± 18 years, 12 male). Change in QTc interval after mexiletine was compared between LQT3 (n=15, 24 ± 21 years, 9 male) and other LQT patients (4 LQT1 and 12 LQT2; 34 ± 14 years, 3 male). Baseline RR, QT, and QTc interval were not different between the 2 groups (981 ± 182 vs. 1,023 ± 192 ms; 550 ± 94 vs. 524 ± 75 ms; 556 ± 66 vs. 520 ± 62 ms, respectively). While QTc interval was shortened with mexiletine in both groups (P<0.0001 vs. baseline), degree of QTc shortening (∆QTc) was significantly larger in LQT3 than in LQT1/LQT2 patients (99 ± 39 vs. 48 ± 32 ms; P=0.0004). The sensitivity, specificity and predictive accuracy of mexiletine infusion test for differentiating LQT3 from LQT1/LQT2 were 86.7%, 81.3% and 81.3%, respectively, and the optimal cut-off for ∆QTc was 69 ms on receiver operating characteristic analysis. No pro-arrhythmic event was observed. CONCLUSIONS: Pronounced shortening of QT interval with mexiletine may facilitate genetic testing in patients with LQT3 syndrome.


Assuntos
Eletrocardiografia , Síndrome do QT Longo/fisiopatologia , Mexiletina/administração & dosagem , Adolescente , Adulto , Criança , Pré-Escolar , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
8.
JAMA Cardiol ; 9(1): 72-77, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38019505

RESUMO

Importance: In treating atrial fibrillation, pulsed field ablation (PFA) is a novel energy modality with comparable efficacy to conventional thermal ablation, such as radiofrequency ablation (RFA), but with the benefit of some preferentiality to myocardial tissue ablation. Studies have demonstrated important safety advantages, including the absence of esophageal injury or pulmonary vein stenosis and only rare phrenic nerve injury. However, there is emerging evidence of coronary artery vasospasm provoked by PFA. Objective: To compare the incidence and severity of left circumflex arterial vasospasm between PFA and RFA during adjacent ablation along the mitral isthmus. Design, Setting, and Participants: This prospective cohort study enrolled consecutive adult patients receiving first-ever PFA or RFA of the mitral isthmus during catheter ablation of atrial fibrillation in 2022 with acute follow-up at a single referral European center. Exposure: A posterolateral mitral isthmus line was created using either a multielectrode pentaspline PFA catheter (endocardial ablation) or a saline-irrigated RFA catheter. Simultaneous diagnostic coronary angiography was performed before, during, and after catheter ablation. Nitroglycerin was planned for spasm persisting beyond 20 minutes or for significant electrocardiographic changes. Main Outcomes and Measures: The frequency and severity of left circumflex arterial vasospasm was assessed and monitored, as were time to remission and any need for nitroglycerin administration. Results: Of 26 included patients, 19 (73%) were male, and the mean (SD) age was 65.5 (9.3) years. Patients underwent either PFA (n = 17) or RFA (n = 9) along the mitral isthmus. Coronary spasm was observed in 7 of 17 patients (41.2%) undergoing PFA: in 7 of 9 (77.8%) when the mitral isthmus ablation line was situated superiorly and in 0 of 8 when situated inferiorly. Conversely, coronary spasm did not occur in any of the 9 patients undergoing RFA. Of 5 patients in whom crossover PFA was performed after RFA failed to achieve conduction block, coronary spasm occurred in 3 (60%). Most instances of spasm (9 of 10 [90%]) were subclinical, with 2 (20%) requiring nitroglycerin administration. The median (range) time to resolution of spasm was 5 (5-25) minutes. Conclusion and Relevance: When creating a mitral isthmus ablation line during catheter ablation of atrial fibrillation, adjacent left circumflex arterial vasospasm frequently occurred with PFA and not RFA but was typically subclinical.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Vasoespasmo Coronário , Adulto , Humanos , Masculino , Idoso , Feminino , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Vasoespasmo Coronário/etiologia , Nitroglicerina , Estudos Prospectivos , Ablação por Cateter/efeitos adversos , Átrios do Coração/fisiopatologia
9.
J Interv Card Electrophysiol ; 67(1): 53-60, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36805921

RESUMO

BACKGROUND: Visually guided laser balloon ablation is known as an effective pulmonary vein (PV) isolation device. The third-generation laser balloon ablation system (X3) equipped with compliant balloon and an automated motor-driven laser output mechanism, namely RAPID mode, has been clinically proven for PV isolation. METHODS: PV isolation with X3 was performed in all the patients with paroxysmal and early-stage persistent atrial fibrillation (AF). Acute data for PV isolation and clinical outcomes including supraventricular tachyarrhythmia (SVT: AF, atrial flutter, or atrial tachycardia)-free survival rate beyond 1 year were analyzed. RESULTS: A total of 110 patients (62 ± 13 years old, 80% of paroxysmal AF) were treated with X3. RAPID mode with was utilized to achieve PV isolation in all cases. In combination with RAPID mode and spot mode laser ablation, 91.1% (380/417) of veins were isolated on the first circumferential lesion set and did not require touch-up ablation and during the index procedure 100% of attempted veins were isolated. The mean procedure time was 77.0 ± 22.7 min and LA dwell time was 61.9 ± 22.0 min. Total duration of laser application was 5.1 ± 2.3 min per vein. At 1 year, SVT-free survival rate was 93.7% in paroxysmal AF patients, and 81.1% in persistent AF patients. CONCLUSIONS: A novel continuous automatic laser balloon ablation system was proved to be safe and effective for both paroxysmal and persistent AF patients. The clinical result demonstrated that PV isolation with X3 could achieve a high SVT-free survival rate.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Terapia a Laser , Veias Pulmonares , Humanos , Pessoa de Meia-Idade , Idoso , Resultado do Tratamento , Terapia a Laser/métodos , Veias Pulmonares/cirurgia , Ablação por Cateter/métodos
10.
Heart Rhythm ; 2024 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-38768840

RESUMO

BACKGROUND: During pulsed field ablation (PFA), electrode-tissue proximity optimizes lesion quality. A novel "single-shot" map-and-ablate spherical multielectrode PFA array catheter that is able to verify electrode-tissue contact was recently studied in a first-in-human trial of atrial fibrillation (AF). OBJECTIVE: The aim of this study was to report lesion durability data, safety, and 12-month effectiveness outcomes. METHODS: The spherical PFA catheter, an all-in-one mapping and ablation system, was used to render anatomy and to deliver biphasic pulses (ungated 1.7 kV pulses; ∼40 seconds/application). Ablation sites included pulmonary veins (PVs) and, in selected patients, posterior wall and mitral isthmus. Follow-up was invasive remapping at ∼3 months, electrocardiograms, Holter monitoring at 6 and 12 months, and symptomatic and scheduled transtelephonic monitoring. The primary and secondary efficacy end points were acute PV isolation (PVI), PVI durability, and atrial arrhythmia recurrence. RESULTS: In the 48-patient AF cohort (paroxysmal, 48%; persistent, 52%), lesion sets included PVI (n = 48; 1.2 applications/PV), posterior wall (n = 20; 3.6 applications/posterior wall), and mitral isthmus (n = 11; 2.9 applications/mitral isthmus). Lesions were acutely successful for all 187 of 187 PVs (100%), 20 of 20 posterior walls (100%), and 10 of 11 mitral isthmuses (91%). Pulse delivery time, left atrial catheter dwell time, and procedure time were 61.5 ± 32.8 seconds, 53.9 ± 26.5 minutes, and 87.8 ± 29.8 minutes, respectively. Remapping (43/48 patients [89.5%]) revealed that 158 of 169 PVs (93.5%) were durably isolated. The only complication was a drug-responsive pericarditis. The 1-year Kaplan-Meier estimates of freedom from atrial arrhythmia were 84.2% (paroxysmal AF) and 80.0% (persistent AF). CONCLUSION: The single-shot spherical array PFA catheter can safely achieve durable lesions, translating into good clinical efficacy. GOV IDENTIFIER: NCT05164107.

11.
JACC Clin Electrophysiol ; 10(5): 885-896, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38385916

RESUMO

BACKGROUND: In treating atrial fibrillation, pulsed-field ablation (PFA) has comparable efficacy to conventional thermal ablation, but with important safety advantages: no esophageal injury or pulmonary vein stenosis, and rare phrenic nerve injury. However, when PFA is delivered in proximity to coronary arteries using a pentaspline catheter, which generates a broad electrical field, severe vasospasm can be provoked. OBJECTIVES: The authors sought to study the vasospastic potential of a focal PFA catheter with a narrower electrical field and develop a preventive strategy with nitroglycerin. METHODS: During atrial fibrillation ablation, a focal PFA catheter was used for cavotricuspid isthmus ablation. Angiography of the right coronary artery (some with fractional flow reserve measurement) was performed before, during, and after PFA. Beyond no nitroglycerin (n = 5), and a few testing strategies (n = 8), 2 primary nitroglycerin administration strategies were studied: 1) multiple boluses (3-2 mg every 2 min) into the right atrium (n = 10), and 2) a bolus (3 mg) into the right atrium with continuous peripheral intravenous infusion (1 mg/min; n = 10). RESULTS: Without nitroglycerin, cavotricuspid isthmus ablation provoked moderate-severe vasospasm in 4 of 5 (80%) patients (fractional flow reserve 0.71 ± 0.08). With repetitive nitroglycerin boluses, severe spasm did not occur, and mild-moderate vasospasm occurred in only 2 of 10 (20%). Using the bolus + infusion strategy, severe and mild-moderate spasm occurred in 1 and 3 of 10 patients (aggregate 40%). No patient had ST-segment changes. CONCLUSIONS: Ablation of the cavotricuspid isthmus using a focal PFA catheter routinely provokes right coronary vasospasm. Pretreatment with high doses of parenteral nitroglycerin prevents severe spasm.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Vasoespasmo Coronário , Nitroglicerina , Humanos , Fibrilação Atrial/cirurgia , Nitroglicerina/administração & dosagem , Nitroglicerina/uso terapêutico , Vasoespasmo Coronário/prevenção & controle , Masculino , Pessoa de Meia-Idade , Feminino , Ablação por Cateter/métodos , Ablação por Cateter/efeitos adversos , Idoso , Vasodilatadores/uso terapêutico , Vasodilatadores/administração & dosagem , Angiografia Coronária , Vasos Coronários/efeitos dos fármacos , Vasos Coronários/cirurgia , Vasos Coronários/fisiopatologia
12.
Artigo em Inglês | MEDLINE | ID: mdl-38842972

RESUMO

BACKGROUND: Electrographic flow (EGF) mapping enables full spatiotemporal reconstruction of organized wavefront propagation to identify extrapulmonary vein sources of atrial fibrillation (AF). OBJECTIVES: FLOW-AF (A Randomized Controlled Study to Evaluate the Reliability of the Ablacon Electrographic FLOW [EGF] Algorithm Technology [Ablamap Software] to Identify AF Sources and Guide Ablation Therapy in Patients With Persistent Atrial Fibrillation) was multicenter, randomized controlled study of EGF mapping to: 1) stratify a nonparoxysmal AF population undergoing redo ablation; 2) guide ablation of these extrapulmonary vein AF sources; and 3) improve AF recurrence outcomes. METHODS: FLOW-AF enrolled persistent atrial fibrillation (PerAF)/long-standing PerAF patients undergoing redo ablation at 4 centers. One-minute EGF maps were recorded from standardized biatrial basket positions. Patients with source activity ≥26.5% were randomized 1:1 to PVI + EGF-guided ablation vs PVI only; patients without sources ≥26.5% threshold were not randomized. Follow-up and electrocardiographic monitoring occurred at 3, 6, and 12 months. RESULTS: We enrolled 85 patients (age 65.6 ± 9.3 years, 37% female, 24% long-standing PerAF). Thirty-four (40%) patients had no sources greater than threshold; at least 1 source greater than threshold was present in 46 (60%) (EGF-guided ablation, n = 22; control group, n = 26). Patients with sources were older (68.2 vs 62.6 years; P = 0.005) with higher CHA2DS2-VASc scores (2.8 vs 1.9; P = 0.001). The freedom from safety events was 97.2%, and 95% of EGF-identified sources were successfully ablated. In randomized patients, AF-free survival at 12 months was 68% for EGF-guided ablation vs 17% for the control group (P = 0.042); freedom from AF/atrial tachycardia/atrial flutter at 12 months was 51% vs 14% (P = 0.103), respectively. CONCLUSIONS: In nonparoxysmal AF patients undergoing redo ablation, EGF mapping identified AF sources in 60% of patients, and could be successfully ablated in 95%. Compared with PVI alone, PVI + source ablation improved AF-free survival by 51% on an absolute basis. (FLOW-AF: A Study to Evaluate the Ablacon Electrographic FLOW EGF Technology [A Randomized Controlled Study to Evaluate the Reliability of the Ablacon Electrographic FLOW (EGF) Algorithm Technology (Ablamap Software) to Identify AF Sources and Guide Ablation Therapy in Patients With Persistent Atrial Fibrillation]; NCT04473963).

13.
JACC Clin Electrophysiol ; 10(2): 270-283, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37999669

RESUMO

BACKGROUND: Strokes after left atrial appendage closure (LAAC) prophylaxis are generally less severe than those after warfarin prophylaxis-thought to be secondary to more hemorrhagic strokes with warfarin. Hemorrhagic strokes are similarly infrequent with direct oral anticoagulant (DOAC) prophylaxis, so the primary subtype after either LAAC or DOAC prophylaxis is ischemic stroke (IS). OBJECTIVES: The purpose of this study was to compare the severity of IS using the modified Rankin Scale in atrial fibrillation patients receiving prophylaxis with DOACs vs LAAC. METHODS: A retrospective analysis was performed of consecutive patients undergoing LAAC at 8 centers who developed an IS (ISLAAC) compared with contemporaneous consecutive patients who developed IS during treatment with DOACs (ISDOAC). The primary outcome was disabling/fatal stroke (modified Rankin Scale 3-5) at discharge and 3 months later. RESULTS: Compared with ISDOAC patients (n = 322), ISLAAC patients (n = 125) were older (age 77.2 ± 13.4 years vs 73.1 ± 11.9 years; P = 0.002), with higher HAS-BLED scores (3.0 vs 2.0; P = 0.004) and more frequent prior bleeding events (54.4% vs 23.6%; P < 0.001), but similar CHA2DS2-VASc scores (5.0 vs 5.0; P = 0.28). Strokes were less frequently disabling/fatal with ISLAAC than ISDOAC at both hospital discharge (38.3% vs 70.3%; P < 0.001) and 3 months later (33.3% vs 56.2%; P < 0.001). Differences in stroke severity persisted after propensity score matching. By multivariate regression analysis, ISLAAC was independently associated with fewer disabling/fatal strokes at discharge (OR: 0.22; 95% CI: 0.13-0.39; P < 0.001) and 3 months (OR: 0.25; 95% CI: 0.12-0.50; P < 0.001), and fewer deaths at 3 months (OR: 0.28; 95% CI: 0.12-0.64; P < 0.001). CONCLUSIONS: Ischemic strokes in patients with atrial fibrillation are less often disabling or fatal with LAAC than DOAC prophylaxis.


Assuntos
Fibrilação Atrial , Acidente Vascular Cerebral Hemorrágico , AVC Isquêmico , Acidente Vascular Cerebral , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Varfarina/efeitos adversos , Fibrilação Atrial/complicações , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/cirurgia , AVC Isquêmico/induzido quimicamente , AVC Isquêmico/complicações , AVC Isquêmico/tratamento farmacológico , Acidente Vascular Cerebral Hemorrágico/induzido quimicamente , Acidente Vascular Cerebral Hemorrágico/complicações , Acidente Vascular Cerebral Hemorrágico/tratamento farmacológico , Estudos Retrospectivos , Oclusão do Apêndice Atrial Esquerdo , Resultado do Tratamento , Anticoagulantes/efeitos adversos , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Hemorragia/induzido quimicamente
14.
Artigo em Inglês | MEDLINE | ID: mdl-38869506

RESUMO

BACKGROUND: Atrial fibrillation (AF) and heart failure (HF) coexist, increasing morbidity and mortality. Studies have demonstrated improved outcomes following AF ablation in HF patients with reduced ejection fraction (EF). OBJECTIVE: To assess the outcomes of pulsed-field ablation (PFA) in HF. METHODS: MANIFEST-PF is a multicenter patient-level registry of consecutive patients undergoing PFA for paroxysmal (PAF) or persistent AF (PerAF). In this sub-study, patients were stratified as: no history of HF (no-HF), HF with preserved EF (HFPEF; LVEF≥50%) or HF with reduced/mildly-reduced EF (HFMR/REF; LVEF<50%). The primary effectiveness and safety endpoints were freedom from documented atrial arrhythmias lasting ≥30s and major adverse events (MAEs), respectively. RESULTS: Of the 1,381 patients, 85% (n=1,174) were no-HF, 6.2% (n=87) were HFPEF, and 8.6% (n=120) were HFMR/REF. No-HF patients had less PerAF than patients with HF (p<0.001), with no difference between HF subtypes (p=1.00). The 1-year freedom from atrial arrhythmia was significantly higher in no-HF than with HFPEF or HFMR/REF (79.9%, 71.3%, 67.5%, p<0.001), but similar between HFMR/REF and HFPEF (p=0.26). However, there was no significant difference in freedom from atrial arrhythmia among patients with no-HF vs HFPEF vs HFMR/REF for those with PAF (82.8%/82.4%/71.7%, p=0.09) and PerAF (73.3%, 64.2%, and 64.9%, p=0.14.MAE rates were similar between the no-HF, HFPEF and HFMR/REF groups (1.9%, 0%, and 2.5%, respectively). CONCLUSION: PFA appears to be potentially safe and effective in AF patients with HF. Freedom from atrial arrhythmia post-PFA was higher in patients without a history of HF, with no significant difference between HF subtypes.

15.
Artigo em Inglês | MEDLINE | ID: mdl-38864809

RESUMO

BACKGROUND: Atrial fibrillation (AF) and heart failure (HF) coexist, increasing morbidity and mortality. Studies have demonstrated improved outcomes following AF ablation in HF patients with reduced ejection fraction (EF). OBJECTIVE: This study sought to assess the outcomes of pulsed field ablation (PFA) in HF. METHODS: MANIFEST-PF (Multi-National Survey on the Methods, Efficacy, and Safety on the Post-Approval Clinical Use of Pulsed Field Ablation) is a multicenter, patient-level registry of consecutive patients undergoing PFA for paroxysmal AF or persistent AF (PerAF). In this substudy, patients were stratified as no history of HF (no-HF), HF with preserved EF (HFpEF) (left ventricular EF of ≥50%) or HF with reduced/mildly reduced EF (HFmr/rEF) (left ventricular EF of <50%). The primary effectiveness and safety endpoints were freedom from documented atrial arrhythmias lasting ≥30 seconds and major adverse events, respectively. RESULTS: Of the 1,381 patients, 85% (n = 1,174) were no-HF, 6.2% (n = 87) were HFpEF, and 8.6% (n = 120) were HFmr/rEF. No-HF patients had less PerAF than patients with HF (P < 0.001), with no difference between HF subtypes (P = >0.99). The 1-year freedom from atrial arrhythmia was significantly higher in no-HF patients than in those with HFpEF or HFmr/rEF (79.9%, 71.3%, and 67.5%, respectively; P < 0.001) but similar between patients with HFmr/rEF and HFpEF (P = 0.26). However, there was no significant difference in freedom from atrial arrhythmia among patients with no-HF vs HFpEF vs HFmr/rEF for those with paroxysmal AF (82.8%, 82.4%, and 71.7%, respectively; P = 0.09) and PerAF (73.3%, 64.2%, and 64.9%, respectively; P = 0.14). Major adverse event rates were similar between the no-HF, HFpEF, and HFmr/rEF groups (1.9%, 0%, and 2.5%, respectively). CONCLUSIONS: PFA appears to be potentially safe and effective in AF patients with HF. Freedom from atrial arrhythmia post-PFA was higher in patients without a history of HF, with no significant difference between HF subtypes.

16.
JACC Clin Electrophysiol ; 10(5): 900-912, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38430087

RESUMO

BACKGROUND: Pulmonary vein isolation (PVI) alone is insufficient to treat many patients with persistent atrial fibrillation (PersAF). Adjunctive left atrial posterior wall (LAPW) ablation with thermal technologies has revealed lack of efficacy, perhaps limited by the difficulty in achieving lesion durability amid concerns of esophageal injury. OBJECTIVES: This study aims to compare the safety and effectiveness of PVI + LAPW ablation vs PVI in patients with PersAF using pulsed-field ablation (PFA). METHODS: In a retrospective analysis of the MANIFEST-PF (Multi-National Survey on the Methods, Efficacy, and Safety on the Post-approval Clinical Use of Pulsed Field Ablation) registry, we studied consecutive PersAF patients undergoing post-approval treatment with a pentaspline PFA catheter. The primary effectiveness outcome was freedom from any atrial arrhythmia of ≥30 seconds. Safety outcomes included the composite of acute and chronic major adverse events. RESULTS: Of the 547 patients with PersAF who underwent PFA, 131 (24%) received adjunctive LAPW ablation. Compared to PVI-alone, patients receiving adjunctive LAPW ablation were younger (65 vs 67 years of age, P = 0.08), had a lower CHA2DS2-VASc score (2.3 ± 1.6 vs 2.6 ± 1.6, P = 0.08), and were more likely to receive electroanatomical mapping (48.1% vs 39.0%, P = 0.07) and intracardiac echocardiography imaging (46.1% vs 17.1%, P < 0.001). The 1-year Kaplan-Meier estimate for freedom from atrial arrhythmias was not statistically different between groups in the full (PVI + LAPW: 66.4%; 95% CI: 57.6%-74.4% vs PVI: 73.1%; 95% CI: 68.5%-77.2%; P = 0.68) and propensity-matched cohorts (PVI + LAPW: 71.7% vs PVI: 68.5%; P = 0.34). There was also no significant difference in major adverse events between the groups (2.2% vs 1.4%, respectively, P = 0.51). CONCLUSIONS: In patients with PersAF undergoing PFA, as compared to PVI-alone, adjunctive LAPW ablation did not improve freedom from atrial arrhythmia at 12 months.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Átrios do Coração , Veias Pulmonares , Humanos , Fibrilação Atrial/cirurgia , Masculino , Feminino , Idoso , Ablação por Cateter/métodos , Ablação por Cateter/efeitos adversos , Pessoa de Meia-Idade , Estudos Retrospectivos , Átrios do Coração/cirurgia , Veias Pulmonares/cirurgia , Resultado do Tratamento , Sistema de Registros
17.
J Interv Card Electrophysiol ; 66(2): 343-351, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35581464

RESUMO

BACKGROUND: Catheter ablation (CA) technology development reflects the need to improve the effectiveness of atrial fibrillation (AF) treatment. Recently, the DiamondTemp Ablation (DTA) RF generator software was updated with a more responsive power ramp. METHODS: DIAMOND FASTR-AF was a prospective, single-arm, multicenter trial. This study sought to characterize the performance of the updated DTA system for the treatment of patients with drug-refractory paroxysmal and persistent AF (PAF and PsAF). The primary effectiveness endpoint was freedom from atrial arrhythmia recurrence following a 90-day blanking period through 12 months, and the primary safety endpoint was a composite of serious adverse events. RESULTS: In total, 60 subjects (34 PAF and 26 PsAF) underwent CA at three centers. Patients were 71.7% male, (age 63.9 ± 10.2 years, with an AF diagnosis duration 3.1 ± 3.9 years and left atrial size 4.4 ± 0.8 cm). Pulmonary vein isolation-only ablation strategy was performed in 34 (56.7%) subjects. The procedural characteristics show a procedure time 90.8 ± 31.6 min, total RF time 14.7 ± 7.7 min, ablation duration 10.7 ± 3.6 s, and fluid infusion 284.7 ± 111.5 ml. The serious adverse event rate was 8.3% (5/60), 3 pulmonary edema and 2 extended hospitalizations. Freedom from atrial arrhythmia recurrence was achieved in 67.6% of subjects by 12 months. CONCLUSIONS: The updated DTA system demonstrated long-term safety and effectiveness through 12 months of post-ablation follow-up for patients with atrial fibrillation. Additionally, procedures were demonstrated to be highly efficient with short procedure times and low levels of fluid infusion. TRIAL REGISTRATION: Sponsored by Medtronic, Inc.; FASTR-AF ClinicalTrials.gov; NCT03626649.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Fibrilação Atrial/cirurgia , Estudos Prospectivos , Temperatura , Resultado do Tratamento , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Recidiva
18.
JACC Clin Electrophysiol ; 9(5): 638-648, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36828771

RESUMO

BACKGROUND: Preclinical studies have revealed that pulsed field ablation (PFA) lesion dimensions increase with repetitive applications at a similar electric field. OBJECTIVES: This study investigated whether pulmonary vein isolation (PVI) durability varies with single vs repetitive pulsed field (PF) applications. METHODS: Atrial fibrillation patients underwent PVI using a spherical multielectrode array PFA catheter delivered with a 19-F deflectable sheath under intracardiac echocardiographic guidance. Esophagogastroduodenoscopy and brain magnetic resonance imaging were performed within 1 to 3 days, and invasive remapping at ∼2 to 3 months. RESULTS: The patient cohort (n = 21; age 63 ± 11 years; 67% women) underwent PVI in either of 2 groups: group 1 (n = 11)-single PF application/PV; and group 2 (n = 10)-3 PF applications/PV. In both groups, PVI was acutely successful in all (100%) patients. Despite significantly longer pulse delivery times (75.2 ± 7.4 s/patient vs 24.5 ± 5.5 s/patient) the procedure times (73.2 ± 13.7 minutes vs 93.7 ± 18.5 minutes) were shorter with group 2 vs group 1. There was no stroke/transient ischemic attack, pericardial effusion, phrenic nerve injury, or esophageal complications. Esophagogastroduodenoscopy was normal in both groups of patients (n = 9). Screening brain magnetic resonance imaging revealed asymptomatic cerebral lesions (diffusion weighted imaging+/fluid attenuated inversion recovery-) in 3 of 16 (18.7%) patients. PV remapping revealed durable PVI in 62.5% PVs in group 1 (n = 10), compared with all 100% PVs in group 2 (n = 9); this translates to all PVs being durably isolated in 30% vs 100% (P < 0.05) of patients in groups 1 and 2, respectively. CONCLUSIONS: In his first-in-human trial, the "single-shot" spherical array PFA catheter was shown to safely isolate PVs. Repetitive PF application is key for lesion consolidation to maximize PVI durability.


Assuntos
Ablação por Cateter , Veias Pulmonares , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Masculino , Resultado do Tratamento , Fatores de Tempo , Ablação por Cateter/métodos , Frequência Cardíaca , Catéteres , Veias Pulmonares/cirurgia
19.
Circ Arrhythm Electrophysiol ; 16(10): e012018, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37727989

RESUMO

BACKGROUND: During electrophysiological mapping of tachycardias, putative target sites are often only truly confirmed to be vital after observing the effect of ablation. This lack of mapping specificity potentiates inadvertent ablation of innocent cardiac tissue not relevant to the arrhythmia. But if myocardial excitability could be transiently suppressed at critical regions, their suitability as targets could be conclusively determined before delivering tissue-destructive ablation lesions. We studied whether reversible pulsed electric fields (PFREV) could transiently suppress electrical conduction, thereby providing a means to dissect tachycardia circuits in vivo. METHODS: PFREV energy was delivered from a 9-mm lattice-tip catheter to the atria of 12 swine and 9 patients, followed by serial electrogram assessments. The effects on electrical conduction were explored in 5 additional animals by applying PFREV to the atrioventricular node: 17 low-dose (PFREV-LOW) and 10 high-dose (PFREV-HIGH) applications. Finally, in 3 patients manifesting spontaneous tachycardias, PFREV was applied at putative critical sites. RESULTS: In animals, the immediate post-PFREV electrogram amplitudes diminished by 74%, followed by 78% recovery by 5 minutes. Similarly, in patients, a 69.9% amplitude reduction was followed by 84% recovery by 3 minutes. Histology revealed only minimal to no focal, superficial fibrosis. PFREV-LOW at the atrioventricular node resulted in transient PR prolongation and transient AV block in 59% and 6%, while PFREV-HIGH caused transient PR prolongation and transient AV block in 30% and 50%, respectively. The 3 tachycardia patients had atypical atrial flutters (n=2) and atrioventricular nodal reentrant tachycardia. PFREV at putative critical sites reproducibly terminated the tachycardias; ablation rendered the tachycardias noninducible and without recurrence during 1-year follow-up. CONCLUSIONS: Reversible electroporation pulses can be applied to myocardial tissue to transiently block electrical conduction. This technique of pulsed field mapping may represent a novel electrophysiological tool to help identify the critical isthmus of tachycardia circuits.


Assuntos
Bloqueio Atrioventricular , Ablação por Cateter , Taquicardia por Reentrada no Nó Atrioventricular , Humanos , Animais , Suínos , Técnicas Eletrofisiológicas Cardíacas , Eletrocardiografia , Nó Atrioventricular , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
20.
JACC Clin Electrophysiol ; 9(8 Pt 3): 1786-1801, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37227340

RESUMO

BACKGROUND: Because of its safety, "single-shot" pulsed field ablation (PFA) catheters have been developed for pulmonary vein isolation (PVI). However, most atrial fibrillation (AF) ablation procedures are performed with focal catheters to permit flexibility of lesion sets beyond PVI. OBJECTIVES: This study sought to determine the safety and efficacy of a focal ablation catheter able to toggle between radiofrequency ablation (RFA) or PFA to treat paroxysmal or persistent AF. METHODS: In a first-in-human study, a focal 9-mm lattice tip catheter was used for PFA posteriorly and either irrigated RFA (RF/PF) or PFA (PF/PF) anteriorly. Protocol-driven remapping was at ∼3 months postablation. The remapping data prompted PFA waveform evolution: PULSE1 (n = 76), PULSE2 (n = 47), and the optimized PULSE3 (n = 55). RESULTS: The study included 178 patients (paroxysmal/persistent AF = 70/108). Linear lesions, either PFA or RFA, included 78 mitral, 121 cavotricuspid isthmus, and 130 left atrial roof lines. All lesion sets (100%) were acutely successful. Invasive remapping of 122 patients revealed improvement of PVI durability with waveform evolution: PULSE1: 51%; PULSE2: 87%; and PULSE3: 97%. After 348 ± 652 days of follow-up, the 1-year Kaplan-Meier estimates for freedom from atrial arrhythmias were 78.3% ± 5.0% and 77.9% ± 4.1% for paroxysmal and persistent AF, respectively, and 84.8% ± 4.9% for the subset of persistent AF patients receiving the PULSE3 waveform. There was 1 primary adverse event-inflammatory pericardial effusion not requiring intervention. CONCLUSIONS: AF ablation with a focal RF/PF catheter allows efficient procedures, chronic lesion durability, and good freedom from atrial arrhythmias-for both paroxysmal and persistent AF. (Safety and Performance Assessment of the Sphere-9 Catheter and the Affera Mapping and RF/PF Ablation System to Treat Atrial Fibrillation; NCT04141007 and NCT04194307).


Assuntos
Técnicas de Ablação , Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/cirurgia , Catéteres , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa