Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 65
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-39148448

RESUMO

The prevalence of white matter disease increases with age and is associated with cerebrovascular disease, cognitive decline, and risk for dementia. MRI measures of abnormal signal in the white matter (AWM) provide estimates of damage, however, regional patterns of AWM may be differentially influenced by genetic or environmental factors. With our data-driven regional parcellation approach, we created a probability distribution atlas using Vietnam Era Twin Study of Aging (VETSA) data (n = 475, mean age 67.6 years) and applied a watershed algorithm to define separate regional parcellations. We report biometrical twin modeling for five anatomically distinct regions: (1) Posterior, (2) Superior frontal and parietal, (3) Anterior and inferior frontal with deep areas, (4) Occipital, and (5) Anterior periventricular. We tested competing multivariate hypotheses to identify unique influences and to explain sources of covariance among the parcellations. Family aggregation could be entirely explained by additive genetic influences, with additive genetic variance (heritability) ranging from 0.69 to 0.79. Most genetic correlations between parcellations ranged from moderate to high (rg = 0.57-0.85), although two were small (rg = 0.35-0.39), consistent with varying degrees of unique genetic influences. This proof-of-principle investigation demonstrated the value of our novel, data-driven parcellations, with identifiable genetic and environmental differences, for future exploration.

2.
Eur Radiol ; 31(11): 8408-8419, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33899143

RESUMO

OBJECTIVES: To investigate associations between histology and hepatic mechanical properties measured using multiparametric magnetic resonance elastography (MRE) in adults with known or suspected nonalcoholic fatty liver disease (NAFLD) without histologic fibrosis. METHODS: This was a retrospective analysis of 88 adults who underwent 3T MR exams including hepatic MRE and MR imaging to estimate proton density fat fraction (MRI-PDFF) within 180 days of liver biopsy. Associations between MRE mechanical properties (mean shear stiffness (|G*|) by 2D and 3D MRE, and storage modulus (G'), loss modulus (G″), wave attenuation (α), and damping ratio (ζ) by 3D MRE) and histologic, demographic and anthropometric data were assessed. RESULTS: In univariate analyses, patients with lobular inflammation grade ≥ 2 had higher 2D |G*| and 3D G″ than those with grade ≤ 1 (p = 0.04). |G*| (both 2D and 3D), G', and G″ increased with age (rho = 0.25 to 0.31; p ≤ 0.03). In multivariable regression analyses, the association between inflammation grade ≥ 2 remained significant for 2D |G*| (p = 0.01) but not for 3D G″ (p = 0.06); age, sex, or BMI did not affect the MRE-inflammation relationship (p > 0.20). CONCLUSIONS: 2D |G*| and 3D G″ were weakly associated with moderate or severe lobular inflammation in patients with known or suspected NAFLD without fibrosis. With further validation and refinement, these properties might become useful biomarkers of inflammation. Age adjustment may help MRE interpretation, at least in patients with early-stage disease. KEY POINTS: • Moderate to severe lobular inflammation was associated with hepatic elevated shear stiffness and elevated loss modulus (p =0.04) in patients with known or suspected NAFLD without liver fibrosis; this suggests that with further technical refinement these MRE-assessed mechanical properties may permit detection of inflammation before the onset of fibrosis in NAFLD. • Increasing age is associated with higher hepatic shear stiffness, and storage and loss moduli (rho = 0.25 to 0.31; p ≤ 0.03); this suggests that age adjustment may help interpret MRE results, at least in patients with early-stage NAFLD.


Assuntos
Técnicas de Imagem por Elasticidade , Hepatopatia Gordurosa não Alcoólica , Biomarcadores , Fibrose , Humanos , Fígado/diagnóstico por imagem , Fígado/patologia , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/patologia , Imageamento por Ressonância Magnética , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Hepatopatia Gordurosa não Alcoólica/patologia , Estudos Prospectivos , Estudos Retrospectivos
3.
Radiology ; 290(3): 682-690, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30561273

RESUMO

Purpose To longitudinally monitor liver fat before and after bariatric surgery by using quantitative chemical shift-encoded (CSE) MRI and to compare with changes in body mass index (BMI), weight, and waist circumference (WC). Materials and Methods For this prospective study, which was approved by the internal review board, a total of 126 participants with obesity who were undergoing evaluation for bariatric surgery with preoperative very low calorie diet (VLCD) were recruited from June 27, 2010, through May 5, 2015. Written informed consent was obtained from all participants. Participants underwent CSE MRI measuring liver proton density fat fraction (PDFF) before VLCD (2-3 weeks before surgery), after VLCD (1-3 days before surgery), and 1, 3, and 6-10 months following surgery. Linear regression was used to estimate rates of change of PDFF (ΔPDFF) and body anthropometrics. Initial PDFF (PDFF0), initial anthropometrics, and anthropometric rates of change were evaluated as predictors of ΔPDFF. Mixed-effects regression was used to estimate time to normalization of PDFF. Results Fifty participants (mean age, 51.0 years; age range, 27-70 years), including 43 women (mean age, 50.8 years; age range, 27-70 years) and seven men (mean age, 51.7 years; age range, 36-62 years), with mean PDFF0 ± standard deviation of 18.1% ± 8.6 and mean BMI0 of 44.9 kg/m2 ± 6.5 completed the study. By 6-10 months following surgery, mean PDFF decreased to 4.9% ± 3.4 and mean BMI decreased to 34.5 kg/m2 ± 5.4. Mean estimated time to PDFF normalization was 22.5 weeks ± 11.5. PDFF0 was the only strong predictor for both ΔPDFF and time to PDFF normalization. No body anthropometric correlated with either outcome. Conclusion Average liver proton density fat fraction (PDFF) decreased to normal (< 5%) by 6-10 months following surgery, with mean time to normalization of approximately 5 months. Initial PDFF was a strong predictor of both rate of change of PDFF and time to normalization. Body anthropometrics did not predict either outcome. Online supplemental material is available for this article. © RSNA, 2018.


Assuntos
Cirurgia Bariátrica , Imageamento por Ressonância Magnética/métodos , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Complicações Pós-Operatórias/diagnóstico por imagem , Adulto , Idoso , Índice de Massa Corporal , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
4.
J Magn Reson Imaging ; 49(5): 1456-1466, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30318834

RESUMO

BACKGROUND: The liver R2* value is widely used as a measure of liver iron but may be confounded by the presence of hepatic steatosis and other covariates. PURPOSE: To identify the most influential covariates for liver R2* values in patients with nonalcoholic fatty liver disease (NAFLD). STUDY TYPE: Retrospective analysis of prospectively acquired data. POPULATION: Baseline data from 204 subjects enrolled in NAFLD/NASH (nonalcoholic steatohepatitis) treatment trials. FIELD STRENGTH: 1.5T and 3T; chemical-shift encoded multiecho gradient echo. ASSESSMENT: Correlation between liver proton density fat fraction and R2*; assessment for demographic, metabolic, laboratory, MRI-derived, and histological covariates of liver R2*. STATISTICAL TESTS: Pearson's and Spearman's correlations; univariate analysis; gradient boosting machines (GBM) multivariable machine-learning method. RESULTS: Hepatic proton density fat fraction (PDFF) was the most strongly correlated covariate for R2* at both 1.5T (r = 0.652, P < 0.0001) and at 3T (r = 0.586, P < 0.0001). In the GBM analysis, hepatic PDFF was the most influential covariate for hepatic R2*, with relative influences (RIs) of 61.3% at 1.5T and 47.5% at 3T; less influential covariates had RIs of up to 11.5% at 1.5T and 16.7% at 3T. Nonhepatocellular iron was weakly associated with R2* at 3T only (RI 6.7%), and hepatocellular iron was not associated with R2* at either field strength. DATA CONCLUSION: Hepatic PDFF is the most influential covariate for R2* at both 1.5T and 3T; nonhepatocellular iron deposition is weakly associated with liver R2* at 3T only. LEVEL OF EVIDENCE: 4 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2019;49:1456-1466.


Assuntos
Tecido Adiposo/diagnóstico por imagem , Ferro/metabolismo , Imageamento por Ressonância Magnética/métodos , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Hepatopatia Gordurosa não Alcoólica/metabolismo , Adolescente , Adulto , Idoso , Criança , Estudos Transversais , Feminino , Humanos , Fígado/diagnóstico por imagem , Fígado/metabolismo , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Prótons , Estudos Retrospectivos , Adulto Jovem
5.
Eur Radiol ; 29(5): 2474-2480, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30547206

RESUMO

OBJECTIVES: The purpose of this study was to (1) evaluate proton density fat fraction (PDFF) distribution across liver segments at baseline and (2) compare longitudinal segmental PDFF changes across time points in adult patients undergoing a very low-calorie diet (VLCD) and subsequent bariatric weight loss surgery (WLS). METHODS: We performed a secondary analysis of data from 118 morbidly obese adult patients enrolled in a VLCD-WLS program. PDFF was estimated using magnitude-based confounder-corrected chemical-shift-encoded (CSE) MRI in each hepatic segment and lobe at baseline (visit 1), after completion of VLCD (visit 2), and at 1, 3, and 6 months (visits 3-5) following WLS. Linear regressions were used to estimate the rate of PDFF change across visits. Lobar and segmental rates of change were compared pairwise. RESULTS: Baseline PDFF was significantly higher in the right lobe compared to the left lobe (p < 0.0001). Lobar and segmental PDFF declined by 3.9-4.5% per month between visits 1 and 2 (preoperative period) and by 4.3-4.8% per month between visits 1 and 3 (perioperative period), but no significant pairwise differences were found in slope between segments and lobes. For visits 3-5 (postoperative period), lobar and segmental PDFF reduction was much less overall (0.4-0.8% PDFF per month) and several pairwise differences were significant; in each case, a right-lobe segment had greater decline than a left-lobe segment. CONCLUSIONS: Baseline and longitudinal changes in fractional fat content in the 5-month postoperative period following WLS vary across segments, with right-lobe segments having higher PDFF at baseline and more rapid reduction in liver fat content. KEY POINTS: • Baseline and longitudinal changes in liver fat following bariatric weight loss surgery vary across liver segments. • Methods that do not provide whole liver fat assessment, such as liver biopsy, may be unreliable in monitoring longitudinal changes in liver fat following weight loss interventions.


Assuntos
Cirurgia Bariátrica/efeitos adversos , Fígado Gorduroso/diagnóstico , Fígado/patologia , Imageamento por Ressonância Magnética/métodos , Obesidade Mórbida/cirurgia , Complicações Pós-Operatórias , Biópsia , Estudos Transversais , Fígado Gorduroso/etiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes
6.
Radiology ; 286(1): 173-185, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29091751

RESUMO

Purpose To determine in a large multicenter multireader setting the interreader reliability of Liver Imaging Reporting and Data System (LI-RADS) version 2014 categories, the major imaging features seen with computed tomography (CT) and magnetic resonance (MR) imaging, and the potential effect of reader demographics on agreement with a preselected nonconsecutive image set. Materials and Methods Institutional review board approval was obtained, and patient consent was waived for this retrospective study. Ten image sets, comprising 38-40 unique studies (equal number of CT and MR imaging studies, uniformly distributed LI-RADS categories), were randomly allocated to readers. Images were acquired in unenhanced and standard contrast material-enhanced phases, with observation diameter and growth data provided. Readers completed a demographic survey, assigned LI-RADS version 2014 categories, and assessed major features. Intraclass correlation coefficient (ICC) assessed with mixed-model regression analyses was the metric for interreader reliability of assigning categories and major features. Results A total of 113 readers evaluated 380 image sets. ICC of final LI-RADS category assignment was 0.67 (95% confidence interval [CI]: 0.61, 0.71) for CT and 0.73 (95% CI: 0.68, 0.77) for MR imaging. ICC was 0.87 (95% CI: 0.84, 0.90) for arterial phase hyperenhancement, 0.85 (95% CI: 0.81, 0.88) for washout appearance, and 0.84 (95% CI: 0.80, 0.87) for capsule appearance. ICC was not significantly affected by liver expertise, LI-RADS familiarity, or years of postresidency practice (ICC range, 0.69-0.70; ICC difference, 0.003-0.01 [95% CI: -0.003 to -0.01, 0.004-0.02]. ICC was borderline higher for private practice readers than for academic readers (ICC difference, 0.009; 95% CI: 0.000, 0.021). Conclusion ICC is good for final LI-RADS categorization and high for major feature characterization, with minimal reader demographic effect. Of note, our results using selected image sets from nonconsecutive examinations are not necessarily comparable with those of prior studies that used consecutive examination series. © RSNA, 2017.


Assuntos
Algoritmos , Carcinoma Hepatocelular/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Radiologistas/estatística & dados numéricos , Radiologistas/normas , Bases de Dados Factuais , Humanos , Imageamento por Ressonância Magnética , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
7.
Eur Respir J ; 52(5)2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30337447

RESUMO

Residual pulmonary vascular obstruction (RPVO) and chronic thromboembolic pulmonary hypertension (CTEPH) are both long-term complications of acute pulmonary embolism, but it is unknown whether RPVO can be predicted by variants of fibrinogen associated with CTEPH.We used the Akaike information criterion to select the best predictive models for RPVO in two prospectively followed cohorts of acute pulmonary embolism patients, using as candidate variables the extent of the initial obstruction, clinical characteristics and fibrinogen-related data. We measured the selected models' goodness of fit by analysis of deviance and compared models using the Chi-squared test.RPVO occurred in 29 (28.4%) out of 102 subjects in the first cohort and 46 (25.3%) out of 182 subjects in the second. The best-fit predictive model derived in the first cohort (p=0.0002) and validated in the second cohort (p=0.0005) implicated fibrinogen Bß-chain monosialylation in the development of RPVO. When the derivation procedure excluded clinical characteristics, fibrinogen Bß-chain monosialylation remained a predictor of RPVO in the best-fit predictive model (p=0.00003). Excluding fibrinogen characteristics worsened the predictive model (p=0.03).Fibrinogen Bß-chain monosialylation, a common structural attribute of fibrin, helped predict RPVO after acute pulmonary embolism. Fibrin structure may contribute to the risk of developing RPVO.


Assuntos
Arteriopatias Oclusivas/diagnóstico , Fibrinogênio/metabolismo , Artéria Pulmonar , Embolia Pulmonar/complicações , Adulto , Idoso , Arteriopatias Oclusivas/etiologia , Feminino , França , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Estudos Prospectivos
8.
Hepatology ; 66(5): 1474-1485, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28493388

RESUMO

Magnetic resonance elastography (MRE) is a promising technique for noninvasive assessment of fibrosis, a major determinant of outcome in nonalcoholic fatty liver disease (NAFLD). However, data in children are limited. The purpose of this study was to determine the accuracy of MRE for the detection of fibrosis and advanced fibrosis in children with NAFLD and to assess agreement between manual and novel automated reading methods. We performed a prospective, multicenter study of two-dimensional (2D) MRE in children with NAFLD. MR elastograms were analyzed manually at two reading centers, and using a new automated technique. Analysis using each approach was done independently. Correlations were determined between MRE analysis methods and fibrosis stage. Thresholds for classifying the presence of fibrosis and of advanced fibrosis were computed and cross-validated. In 90 children with a mean age of 13.1 ± 2.4 years, median hepatic stiffness was 2.35 kPa. Stiffness values derived by each reading center were strongly correlated with each other (r = 0.83). All three analyses were significantly correlated with fibrosis stage (center 1, ρ = 0.53; center 2, ρ = 0.55; and automated analysis, ρ = 0.52; P < 0.001). Overall cross-validated accuracy for detecting any fibrosis was 72.2% for all methods (95% confidence interval [CI], 61.8%-81.1%). Overall cross-validated accuracy for assessing advanced fibrosis was 88.9% (95% CI, 80.5%-94.5%) for center 1, 90.0% (95% CI, 81.9%-95.3%) for center 2, and 86.7% (95% CI, 77.9%-92.9%) for automated analysis. CONCLUSION: 2D MRE can estimate hepatic stiffness in children with NAFLD. Further refinement and validation of automated analysis techniques will be an important step in standardizing MRE. How to best integrate MRE into clinical protocols for the assessment of NAFLD in children will require prospective evaluation. (Hepatology 2017;66:1474-1485).


Assuntos
Técnicas de Imagem por Elasticidade , Fígado/diagnóstico por imagem , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Adolescente , Biomarcadores , Criança , Estudos Transversais , Feminino , Fibrose , Humanos , Fígado/patologia , Masculino , Estudos Prospectivos
9.
J Magn Reson Imaging ; 45(5): 1455-1463, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-27571403

RESUMO

PURPOSE: To investigate the regional variability of adipose tissue triglyceride composition in vivo using 1 H MRS, examining potential confounders and corrections for artifacts, to allow for adipose tissue spectrum estimation. MATERIALS AND METHODS: 1 H magnetic resonance (MR) stimulated echo acquisition mode (STEAM) spectra were acquired in vivo at 3T from 340 adult patients (mean age 48.9 years, range 21-79 years; 172 males, 168 females; mean body mass index [BMI] 34.0, range 22-49 kg/m2 ) with known or suspected nonalcoholic fatty liver disease (NAFLD) in deep (dSCAT), surface (sSCAT) subcutaneous adipose tissue, and visceral adipose tissue (VAT). Triglyceride composition was characterized by the number of double bonds (ndb) and number of methylene-interrupted double bonds (nmidb). A subset of patients (dSCAT n = 80, sSCAT n = 55, VAT n = 194) had the acquisition repeated three times to examine the repeatability of ndb and nmidb estimation. RESULTS: Mean ndb and nmidb showed significant (P < 0.0001) differences between depots except for dSCAT and sSCAT nmidb (dSCAT ndb 2.797, nmidb 0.745; sSCAT ndb 2.826, nmidb 0.737; VAT ndb 2.723, nmidb 0.687). All ndb and nmidb estimates were highly repeatable (VAT ndb ICC = 0.888, nmidb ICC = 0.853; sSCAT: ndb ICC = 0.974, nmidb ICC = 0.964; dSCAT: ndb ICC = 0.959, nmidb ICC = 0.948). CONCLUSION: Adipose tissue composition can be estimated repeatably using 1 H MRS and different fat depots have different triglyceride compositions. LEVEL OF EVIDENCE: 2 J. MAGN. RESON. IMAGING 2017;45:1455-1463.


Assuntos
Gordura Abdominal/diagnóstico por imagem , Gordura Intra-Abdominal/diagnóstico por imagem , Espectroscopia de Ressonância Magnética , Gordura Subcutânea/diagnóstico por imagem , Triglicerídeos/química , Adulto , Idoso , Idoso de 80 Anos ou mais , Artefatos , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Estudos Prospectivos , Espectroscopia de Prótons por Ressonância Magnética , Adulto Jovem
10.
AJR Am J Roentgenol ; 208(5): W168-W177, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28267360

RESUMO

OBJECTIVE: The purpose of this study is to explore the diagnostic performance of two investigational quantitative ultrasound (QUS) parameters, attenuation coefficient and backscatter coefficient, in comparison with conventional ultrasound (CUS) and MRI-estimated proton density fat fraction (PDFF) for predicting histology-confirmed steatosis grade in adults with nonalcoholic fatty liver disease (NAFLD). SUBJECTS AND METHODS: In this prospectively designed pilot study, 61 adults with histology-confirmed NAFLD were enrolled from September 2012 to February 2014. Subjects underwent QUS, CUS, and MRI examinations within 100 days of clinical-care liver biopsy. QUS parameters (attenuation coefficient and backscatter coefficient) were estimated using a reference phantom technique by two analysts independently. Three-point ordinal CUS scores intended to predict steatosis grade (1, 2, or 3) were generated independently by two radiologists on the basis of QUS features. PDFF was estimated using an advanced chemical shift-based MRI technique. Using histologic examination as the reference standard, ROC analysis was performed. Optimal attenuation coefficient, backscatter coefficient, and PDFF cutoff thresholds were identified, and the accuracy of attenuation coefficient, backscatter coefficient, PDFF, and CUS to predict steatosis grade was determined. Interobserver agreement for attenuation coefficient, backscatter coefficient, and CUS was analyzed. RESULTS: CUS had 51.7% grading accuracy. The raw and cross-validated steatosis grading accuracies were 61.7% and 55.0%, respectively, for attenuation coefficient, 68.3% and 68.3% for backscatter coefficient, and 76.7% and 71.3% for MRI-estimated PDFF. Interobserver agreements were 53.3% for CUS (κ = 0.61), 90.0% for attenuation coefficient (κ = 0.87), and 71.7% for backscatter coefficient (κ = 0.82) (p < 0.0001 for all). CONCLUSION: Preliminary observations suggest that QUS parameters may be more accurate and provide higher interobserver agreement than CUS for predicting hepatic steatosis grade in patients with NAFLD.


Assuntos
Imageamento por Ressonância Magnética/métodos , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Ultrassonografia/métodos , Adulto , Idoso , Biópsia , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Hepatopatia Gordurosa não Alcoólica/patologia , Imagens de Fantasmas , Projetos Piloto , Valor Preditivo dos Testes , Estudos Prospectivos
11.
Radiology ; 281(1): 129-39, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27115054

RESUMO

Purpose To determine the proportion of untreated Liver Imaging Reporting and Data System (LI-RADS) version 2014 category 2, 3, and 4 observations that progress, remain stable, or decrease in category and to compare the cumulative incidence of progression in category. Materials and Methods In this retrospective, longitudinal, single-center, HIPAA-compliant, institutional review board-approved study, 157 patients (86 men and 71 women; mean age ± standard deviation, 59.0 years ± 9.7) underwent two or more multiphasic computed tomographic (CT) or magnetic resonance (MR) imaging examinations for hepatocellular carcinoma surveillance, with the first examination in 2011 or 2012. One radiologist reviewed baseline and follow-up CT and MR images (mean follow-up, 614 days). LI-RADS categories issued in the clinical reports by using version 1.0 or version 2013 were converted to version 2014 retrospectively; category modifications were verified with another radiologist. For index category LR-2, LR-3, and LR-4 observations, the proportions that progressed, remained stable, or decreased in category were calculated. Cumulative incidence curves for progression were compared according to baseline LI-RADS category (by using log-rank tests). Results All 63 index LR-2 observations remained stable or decreased in category. Among 166 index LR-3 observations, seven (4%) progressed to LR-5, and eight (5%) progressed to LR-4. Among 52 index LR-4 observations, 20 (38%) progressed to a malignant category. The cumulative incidence of progression to a malignant category was higher for index LR-4 observations than for index LR-3 or LR-2 observations (each P < .001) but was not different between LR-3 and LR-2 observations (P = .155). The cumulative incidence of progression to at least category LR-4 was trend-level higher for index LR-3 observations than for LR-2 observations (P = .0502). Conclusion Observations classified according to LI-RADS version 2014 categories are associated with different imaging outcomes. (©) RSNA, 2016 Online supplemental material is available for this article.


Assuntos
Interpretação de Imagem Assistida por Computador/normas , Hepatopatias/diagnóstico por imagem , Imageamento por Ressonância Magnética/normas , Tomografia Computadorizada por Raios X/normas , Meios de Contraste , Progressão da Doença , Feminino , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Projetos de Pesquisa , Estudos Retrospectivos
12.
Tob Control ; 25(4): 464-9, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-26283713

RESUMO

BACKGROUND: Varenicline is known to have greater efficacy than other pharmacotherapy for treating nicotine dependence and has gained popularity since its introduction in 2006. This study examines if adding varenicline to existing pharmacotherapies increased the population cessation rate. METHODS: Data are from two cross-sectional US Current Population Surveys-Tobacco Use Supplements (2003 and 2010-2011). Smokers and recent quitters 18 or older (N=34 869 in 2003, N=27 751 in 2010-2011) were asked if they had used varenicline, bupropion or nicotine replacement therapies (NRT) in their most recent quit attempt. The annual cessation rate, as well as the per cent of smokers who had quit for ≥3 months, was compared between surveys. RESULTS: Varenicline use increased from 0% in 2003 to 10.9% in 2010-2011, while use of bupropion decreased from 9.1% to 3.5%, and NRT from 24.5% to 22.4%. Use of any pharmacotherapy increased by 2.4 percentage points. Varenicline users stayed on cessation aids longer and were less likely to relapse than users of other pharmacotherapies in the first 3 months of a quit attempt, after which the difference was no longer significant. The change in annual cessation rate was negligible, from 4.5% in 2003 to 4.7% in 2010-2011 (p=0.36). CONCLUSIONS: Addition of varenicline to the list of approved cessation aids has mainly led to displacement of other therapies. As a result, there was no meaningful change in population cessation rate despite a remarkable increase in varenicline use. The population impact of a new therapy is a function of more than efficacy or reach of the therapy.


Assuntos
Abandono do Hábito de Fumar/estatística & dados numéricos , Dispositivos para o Abandono do Uso de Tabaco , Tabagismo/reabilitação , Vareniclina/administração & dosagem , Adolescente , Adulto , Idoso , Bupropiona/administração & dosagem , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Agonistas Nicotínicos/administração & dosagem , Recidiva , Fumantes/estatística & dados numéricos , Inquéritos e Questionários , Fatores de Tempo , Estados Unidos , Adulto Jovem
13.
Clin Infect Dis ; 60(3): 473-80, 2015 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-25362201

RESUMO

BACKGROUND: Human immunodeficiency virus (HIV)-associated neurocognitive disorders (HAND) can show variable clinical trajectories. Previous longitudinal studies of HAND typically have been brief, did not use adequate normative standards, or were conducted in the context of a clinical trial, thereby limiting our understanding of incident neurocognitive (NC) decline and recovery. METHODS: We investigated the incidence and predictors of NC change over 16-72 (mean, 35) months in 436 HIV-infected participants in the CNS HIV Anti-Retroviral Therapy Effects Research cohort. Comprehensive laboratory, neuromedical, and NC assessments were obtained every 6 months. Published, regression-based norms for NC change were used to generate overall change status (decline vs stable vs improved) at each study visit. Survival analysis was used to examine the predictors of time to NC change. RESULTS: Ninety-nine participants (22.7%) declined, 265 (60.8%) remained stable, and 72 (16.5%) improved. In multivariable analyses, predictors of NC improvements or declines included time-dependent treatment status and indicators of disease severity (current hematocrit, albumin, total protein, aspartate aminotransferase), and baseline demographics and estimated premorbid intelligence quotient, non-HIV-related comorbidities, current depressive symptoms, and lifetime psychiatric diagnoses (overall model P < .0001). CONCLUSIONS: NC change is common in HIV infection and appears to be driven by a complex set of risk factors involving HIV disease, its treatment, and comorbid conditions.


Assuntos
Transtornos Cognitivos/epidemiologia , Infecções por HIV/tratamento farmacológico , Adulto , Comorbidade , Feminino , Infecções por HIV/epidemiologia , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade
14.
J Magn Reson Imaging ; 42(3): 811-7, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25620624

RESUMO

PURPOSE: To examine the reproducibility of quantitative magnetic resonance (MR) methods to estimate hepatic proton density fat-fraction (PDFF) at different magnetic field strengths. MATERIALS AND METHODS: This Health Insurance Portability and Accountability Act (HIPAA)-compliant study was approved by the Institutional Review Board. Following informed consent, 25 severely obese subjects (mean body mass index [BMI]: 45 ± 4, range: 38-53 kg/m(2) ) were scanned at 1.5T and 3T on the same day. Two confounder-corrected multiecho chemical shift-encoded gradient-echo-based imaging methods were acquired to estimate PDFF over the entire liver: 3D complex-based (MRI-C) and 2D magnitude-based (MRI-M) MRI. Single-voxel MR spectroscopy (MRS) was performed in the right liver lobe. Using linear regression, pairwise comparisons of estimated PDFF were made between methods (MRI-C, MRI-M, MRS) at each field strength and for each method across field strengths. RESULTS: 1.5T vs. 3T regression analyses for MRI-C, MRI-M, and MRS PDFF measurements yielded R(2) values of 0.99, 0.97, and 0.90, respectively. The best-fit line was near unity (slope(m) = 1, intercept(b) = 0), indicating excellent agreement for each case: MRI-C (m = 0.92 [0.87, 0.99], b = 1.4 [0.7, 1.8]); MRI-M (m = 1.0 [0.90, 1.08], b = -1.4 [-2.4, -0.5]); MRS (m = 0.98 [0.82, 1.15], b = 1.2 [-0.2, 3.0]). Comparing MRI-C and MRI-M yielded an R(2) = 0.98 (m = 1.1 [1.02, 1.16], b = -1.8 [-2.8, -1.1]) at 1.5T, and R(2) = 0.99 (m = 0.98 [0.93, 1.03], b = 1.2 [0.7, 1.7]) at 3T. CONCLUSION: This study demonstrates that PDFF estimation is reproducible across field strengths and across two confounder-corrected MR-based methods.


Assuntos
Tecido Adiposo/patologia , Imageamento por Ressonância Magnética , Obesidade/fisiopatologia , Adulto , Índice de Massa Corporal , Imagem Ecoplanar , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Fígado/patologia , Espectroscopia de Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Hepatopatia Gordurosa não Alcoólica/patologia , Prótons , Análise de Regressão , Reprodutibilidade dos Testes
15.
J Magn Reson Imaging ; 42(5): 1223-32, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25847512

RESUMO

PURPOSE: To assess accuracy of magnitude-based magnetic resonance imaging (M-MRI) in children to estimate hepatic proton density fat fraction (PDFF) using two to six echoes, with magnetic resonance spectroscopy (MRS) -measured PDFF as a reference standard. METHODS: This was an IRB-approved, HIPAA-compliant, single-center, cross-sectional, retrospective analysis of data collected prospectively between 2008 and 2013 in children with known or suspected nonalcoholic fatty liver disease (NAFLD). Two hundred eighty-six children (8-20 [mean 14.2 ± 2.5] years; 182 boys) underwent same-day MRS and M-MRI. Unenhanced two-dimensional axial spoiled gradient-recalled-echo images at six echo times were obtained at 3T after a single low-flip-angle (10°) excitation with ≥ 120-ms recovery time. Hepatic PDFF was estimated using the first two, three, four, five, and all six echoes. For each number of echoes, accuracy of M-MRI to estimate PDFF was assessed by linear regression with MRS-PDFF as reference standard. Accuracy metrics were regression intercept, slope, average bias, and R(2) . RESULTS: MRS-PDFF ranged from 0.2-40.4% (mean 13.1 ± 9.8%). Using three to six echoes, regression intercept, slope, and average bias were 0.46-0.96%, 0.99-1.01, and 0.57-0.89%, respectively. Using two echoes, these values were 2.98%, 0.97, and 2.72%, respectively. R(2) ranged 0.98-0.99 for all methods. CONCLUSION: Using three to six echoes, M-MRI has high accuracy for hepatic PDFF estimation in children.


Assuntos
Fígado Gorduroso/patologia , Fígado/patologia , Imageamento por Ressonância Magnética , Adolescente , Adulto , Criança , Estudos Transversais , Feminino , Humanos , Espectroscopia de Ressonância Magnética , Masculino , Prótons , Reprodutibilidade dos Testes , Estudos Retrospectivos , Adulto Jovem
16.
Am J Public Health ; 105(2): 373-9, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25521868

RESUMO

OBJECTIVES: We examined smoking cessation rate by education and determined how much of the difference can be attributed to the rate of quit attempts and how much to the success of these attempts. METHODS: We analyzed data from the National Health Interview Survey (NHIS, 1991-2010) and the Tobacco Use Supplement to the Current Population Survey (TUS-CPS, 1992-2011). Smokers (≥ 25 years) were divided into lower- and higher-education groups (≤ 12 years and >12 years). RESULTS: A significant difference in cessation rate between the lower- and the higher-education groups persisted over the last 2 decades. On average, the annual cessation rate for the former was about two thirds that of the latter (3.5% vs 5.2%; P<.001, for both NHIS and TUS-CPS). About half the difference in cessation rate can be attributed to the difference in quit attempt rate and half to the difference in success rate. CONCLUSIONS: Smokers in the lower-education group have consistently lagged behind their higher-education counterparts in quitting. In addition to the usual concern about improving their success in quitting, tobacco control programs need to find ways to increase quit attempts in this group.


Assuntos
Escolaridade , Abandono do Hábito de Fumar/estatística & dados numéricos , Adulto , Inquéritos Epidemiológicos , Humanos , Fumar/epidemiologia , Estados Unidos/epidemiologia
17.
AJR Am J Roentgenol ; 204(3): 527-35, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25714281

RESUMO

OBJECTIVE. The purpose of this study is to evaluate the per-patient diagnostic performance of an abbreviated gadoxetic acid-enhanced MRI protocol for hepatocellular carcinoma (HCC) surveillance. MATERIALS AND METHODS. A retrospective review identified 298 consecutive patients at risk for HCC enrolled in a gadoxetic acid-enhanced MRI-based HCC surveillance program. For each patient, the first gadoxetic acid-enhanced MRI was analyzed. To simulate an abbreviated protocol, two readers independently read two image sets per patient: set 1 consisted of T1-weighted 20-minute hepatobiliary phase and T2-weighted single-shot fast spin-echo (SSFSE) images; set 2 included diffusion-weighted imaging (DWI) and images from set 1. Image sets were scored as positive or negative according to the presence of at least one nodule 10 mm or larger that met the predetermined criteria. Agreement was assessed using Cohen kappa statistics. A composite reference standard was used to determine the diagnostic performance of each image set for each reader. RESULTS. Interreader agreement was substantial for both image sets (κ = 0.72 for both) and intrareader agreement was excellent (κ = 0.97-0.99). Reader performance for image set 1 was sensitivity of 85.7% for reader A and 79.6% for reader B, specificity of 91.2% for reader A and 95.2% for reader B, and negative predictive value of 97.0% for reader A and 96.0% for reader B. Reader performance for image set 2 was nearly identical, with only one of 298 examinations scored differently on image set 2 compared with set 1. CONCLUSION. An abbreviated MRI protocol consisting of T2-weighted SSFSE and gadoxetic acid-enhanced hepatobiliary phase has high negative predictive value and may be an acceptable method for HCC surveillance. The inclusion of a DWI sequence did not significantly alter the diagnostic performance of the abbreviated protocol.


Assuntos
Carcinoma Hepatocelular/diagnóstico , Meios de Contraste , Gadolínio DTPA , Neoplasias Hepáticas/diagnóstico , Imageamento por Ressonância Magnética , Idoso , Estudos Transversais , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Vigilância da População , Reprodutibilidade dos Testes , Estudos Retrospectivos
18.
J Magn Reson Imaging ; 39(3): 567-75, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23720420

RESUMO

PURPOSE: To assess the effect of echo-sampling strategy on the accuracy of out-of-phase (OP) and in-phase (IP) multiecho gradient-echo magnetic resonance imaging (MRI) hepatic fat fraction (FF) estimation, using MR spectroscopy (MRS) proton density FF (PDFF) as a reference standard. MATERIALS AND METHODS: In this Institutional Review Board (IRB)-approved, Health Insurance Portability and Accountability Act (HIPAA)-compliant prospective study, 84 subjects underwent proton MRS and non-T1 -weighted gradient-echo imaging of the liver at 3T. Imaging data were collected at 16 nominally OP and IP echo times (TEs). MRI-FF was estimated while varying two echo-sampling parameters (number of consecutive echoes, starting echo number). For each combination of these parameters, MRI-FF estimation accuracy was assessed with slope, intercept, average bias, and R2 from a linear regression of MRS-PDFF on MRI-FF. The relationship between accuracy metrics and echo-sampling parameters was assessed by Spearman rank correlation. RESULTS: For FF calculations using 3-16 echoes and a starting echo number of 1, the intercept ranged from 0.0046 to 0.0124, slope from 0.941 to 0.96, average bias from 0.0034 to 0.0078, and R2 from 0.968 to 0.976. All four accuracy metrics were the best with the 3- and 4-echo calculations and worsened progressively with an increasing number of echoes. For a given number of echoes, there was an overall trend toward decreasing accuracy as starting echo number increased. Spearman correlation coefficients between starting echo number and intercept, slope, average bias, and R2 were 0.911, -0.64, -0.889, and -0.954, respectively, indicating progressive loss of accuracy in each case. CONCLUSION: Multiecho OP and IP imaging provided high FF estimation accuracy. Accuracy was highest using the earliest 3 or 4 echoes. Incorporation of additional echoes or delaying the starting echo number progressively reduced accuracy.


Assuntos
Imagem Ecoplanar/métodos , Fígado Gorduroso/diagnóstico , Interpretação de Imagem Assistida por Computador , Espectroscopia de Ressonância Magnética/métodos , Tecido Adiposo/metabolismo , Adolescente , Adulto , Criança , Estudos Transversais , Fígado Gorduroso/patologia , Feminino , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sensibilidade e Especificidade , Adulto Jovem
19.
J Magn Reson Imaging ; 39(5): 1265-71, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24136736

RESUMO

PURPOSE: To prospectively describe magnitude-based multi-echo gradient-echo hepatic proton density fat fraction (PDFF) inter-examination precision at 3 Tesla (T). MATERIALS AND METHODS: In this prospective, Institutional Review Board-approved, Health Insurance Portability and Accountability Act (HIPAA) compliant study, written informed consent was obtained from 29 subjects (body mass indexes > 30 kg/m2). Three 3T MRI examinations were obtained over 75-90 min. Segmental, lobar, and whole liver PDFF were estimated (using three, four, five, or six echoes) by magnitude-based multi-echo MRI in colocalized regions of interest. For estimate (using three, four, five, or six echoes), at each anatomic level (segmental, lobar, whole liver), three inter-examination precision metrics were computed: intra-class correlation coefficient (ICC), standard deviation (SD), and range. RESULTS: Magnitude-based PDFF estimates using each reconstruction method showed excellent inter-examination precision for each segment (ICC ≥ 0.992; SD ≤ 0.66%; range ≤ 1.24%), lobe (ICC ≥ 0.998; SD ≤ 0.34%; range ≤ 0.64%), and the whole liver (ICC = 0.999; SD ≤ 0.24%; range ≤ 0.45%). Inter-examination precision was unaffected by whether PDFF was estimated using three, four, five, or six echoes. CONCLUSION: Magnitude-based PDFF estimation shows high inter-examination precision at segmental, lobar, and whole liver anatomic levels, supporting its use in clinical care or clinical trials. The results of this study suggest that longitudinal hepatic PDFF change greater than 1.6% is likely to represent signal rather than noise.


Assuntos
Adiposidade , Interpretação de Imagem Assistida por Computador/métodos , Fígado/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Obesidade/diagnóstico , Obesidade/fisiopatologia , Espectroscopia de Prótons por Ressonância Magnética/métodos , Adolescente , Adulto , Criança , Feminino , Humanos , Fígado/patologia , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
20.
J Magn Reson Imaging ; 39(2): 440-7, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23596052

RESUMO

PURPOSE: To evaluate the effect of flip angle (FA) on accuracy and within-examination repeatability of hepatic proton-density fat fraction (PDFF) estimation with complex data-based magnetic resonance imaging (MRI). MATERIALS AND METHODS: PDFF was estimated at 3T in 30 subjects using two sets of five MRI sequences with FA from 1° to 5° in each set. One set used 7 msec repetition time and acquired 6 echoes (TR7/E6); the other used 14 msec and acquired 12 echoes (TR14/E12). For each FA in both sets the accuracy of MRI-PDFF was assessed relative to MR spectroscopy (MRS)-PDFF using four regression parameters (slope, intercept, average bias, R(2) ). Each subject had four random sequences repeated; within-examination repeatability of MRI-PDFF for each FA was assessed with intraclass correlation coefficient (ICC). Pairwise comparisons were made using bootstrap-based tests. RESULTS: Most FAs provided high MRI-PDFF estimation accuracy (intercept range -1.25 to 0.84, slope 0.89-1.06, average bias 0.24-1.65, R(2) 0.85-0.97). Most comparisons of regression parameters between FAs were not significant. Informally, in the TR7/E6 set, FAs of 2° and 3° provided the highest accuracy, while FAs of 1° and 5° provided the lowest. In the TR14/E12 set, accuracy parameters did not differ consistently between FAs. FAs in both sets provided high within-examination repeatability (ICC range 0.981-0.998). CONCLUSION: MRI-PDFF was repeatable and, for most FAs, accurate in both sequence sets. In the TR7/E6 sequence set, FAs of 2° and 3° informally provided the highest accuracy. In the TR14/E12 sequence set, all FAs provided similar accuracy.


Assuntos
Adiposidade/fisiologia , Algoritmos , Artefatos , Interpretação de Imagem Assistida por Computador/métodos , Fígado/fisiologia , Imageamento por Ressonância Magnética/métodos , Adolescente , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Prótons , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa