Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Int Orthop ; 41(3): 513-519, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27889840

RESUMO

PURPOSE: Dual mobility (DM) socket has been associated with a low rate of dislocation following both primary and revision total hip arthroplasty (THA). However, little is known about the long-term efficiency of DM in the treatment of THA instability. The purpose of this retrospective study was to evaluate the outcome of a cemented DM socket to treat recurrent dislocation after a minimum of five year follow-up. METHODS: The series included 51 patients with a mean age of 71.3 ± 11.5 (range, 41-98) years presenting with recurrent dislocation (mean 3.3). A single DM socket design was used consisting of a stainless steel outer shell with grooves with a highly polished inner surface articulating with a mobile polyethylene component. The femoral head was captured in the polyethylene component using a snap-fit type mechanism, the latter acting as a large unconstrained head inside the metal cup. RESULTS: At the minimum five year follow-up evaluation, 18 of the 51 patients deceased at a mean of 4.8 ± 2.3 years, three were lost to follow-up at a mean of 1.4 years, seven had been revised at a mean of 4.7 ± 3.1 years (range, 1.5-9.1), and the remaining 23 were still alive and did not have revision at a mean of 8.2 ± 2.4 years (range, 5-13 years). Of the seven revision, three were performed for further episodes of dislocation (at the large bearing for one patient and intra-prosthetic for two patients) after a mean 5.9 ± 2.9 years (range, 2.7-9.1), whereas two were performed for late sepsis and two for aseptic loosening of the acetabular component. Radiographic analysis did not reveal any further loosening on the acetabular side. The survival rate of the cup at ten years, using re-dislocation as the end-point, was 86.1 ± 8.4% (95% confidence interval, 69.7-100%). The survival rate of the cup at ten years, using revision for any reason as the end-point, was 75.2 ± 9.3% (95% confidence interval, 56.9-93.5%). CONCLUSION: A cemented dual mobility cup was able to restore hip stability in 94% of patients presenting with recurrent dislocating hips up to 13-year follow-up with none of the complications associated with constrained devices, as mechanical failure occurred in only 3.9% of the patients of this series. The overall reduced survival using revision for any reason as the end-point at ten years was related to this specific patients population that had various co-morbidities.


Assuntos
Artroplastia de Quadril/efeitos adversos , Luxação do Quadril/cirurgia , Prótese de Quadril/efeitos adversos , Desenho de Prótese/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Cimentos Ósseos/efeitos adversos , Cimentos Ósseos/uso terapêutico , Feminino , Seguimentos , Luxação do Quadril/etiologia , Articulação do Quadril/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Reoperação , Estudos Retrospectivos , Análise de Sobrevida
2.
Clin Orthop Relat Res ; 468(12): 3248-54, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20532718

RESUMO

BACKGROUND: The treatment of recurrent dislocation after total hip arthroplasty remains challenging. Dual mobility sockets have been associated with a low rate of dislocation but it is not known whether they are useful for treating recurrent dislocation. QUESTIONS/PURPOSES: We therefore asked whether a cemented dual mobility socket would (1) restore hip stability following recurrent dislocation; (2) provide a pain-free and mobile hip; and (3) show durable radiographic fixation. METHODS: We retrospectively reviewed 51 patients treated with a cemented dual mobility socket for recurrent dislocation after total hip arthroplasty between August 2002 and June 2005. The mean age at the time of the index procedure of was 71.3 years. Of the 51 patients, 47 have had complete clinical and radiographic evaluation data at a mean followup of 51.4 months (range, 25-76.3 months). RESULTS: The cemented dual mobility socket restored complete stability of the hip in 45 of the 47 patients (96%). The mean Merle d'Aubigné hip score was 16 ± 2 at the latest followup. Radiographic analysis revealed no or radiolucent lines less than 1 mm thick located in a single acetabular zone in 43 of 47 hips (91.5%). The cumulative survival rate of the acetabular component at 72 months using revision for dislocation and/or mechanical failure as the end point was 96% ± 4% (95% confidence interval, 90%-100%). CONCLUSIONS: A cemented dual mobility socket was able to restore hip stability in 96% of recurrent dislocating hips. However, longer-term followup is needed to ensure that dislocation and loosening rates will not increase.


Assuntos
Artroplastia de Quadril/instrumentação , Cimentos Ósseos/uso terapêutico , Articulação do Quadril/cirurgia , Prótese de Quadril , Luxações Articulares/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/efeitos adversos , Feminino , França , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/fisiopatologia , Humanos , Luxações Articulares/diagnóstico por imagem , Luxações Articulares/etiologia , Luxações Articulares/fisiopatologia , Instabilidade Articular/etiologia , Instabilidade Articular/cirurgia , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Radiografia , Amplitude de Movimento Articular , Recuperação de Função Fisiológica , Recidiva , Reoperação , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
3.
Clin Orthop Relat Res ; 466(2): 389-95, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18196422

RESUMO

UNLABELLED: THA revisions using standard cups are at risk of dislocation (5.1% to 14.4% incidence), especially in patients over 70 years of age. Constrained tripolar cups have reduced this risk (6% incidence) but are associated with substantial loosening rates (9%). The nonconstrained dual mobility cup was designed to improve prosthetic stability (polyethylene head >or= 40 mm diameter) without increasing loosening rates by reducing wear and limiting impingement (rotation range of 108 degrees). We implanted 88 cemented dual mobility cups for THA revisions in 82 patients at high risk of dislocation. Average patient age was 72 years (range, 65-86 years). Eighty-five of the 88 hips were reviewed at 2 to 5 years followup. One patient (1.1%) had a traumatic dislocation at 2 years postoperatively. Two patients (2.3%) had asymptomatic early loosening and three patients (3.5%) had localized radiographic lucencies. These results confirm those with press-fit dual mobility cups suggesting a low dislocation rate at 5 years and a cup survival of 94.6%. At middle term followup, cemented dual mobility cup achieved better results than constrained cups in cases at risk of dislocation and recurrent loosening. LEVEL OF EVIDENCE: Level IV, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.


Assuntos
Artroplastia de Quadril/efeitos adversos , Cimentos Ósseos , Luxação do Quadril/prevenção & controle , Complicações Pós-Operatórias/prevenção & controle , Falha de Prótese , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/instrumentação , Artroplastia de Quadril/estatística & dados numéricos , Luxação do Quadril/diagnóstico por imagem , Luxação do Quadril/epidemiologia , Humanos , Incidência , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/epidemiologia , Radiografia , Reoperação , Estudos Retrospectivos , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa