Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
Clin Orthop Relat Res ; 476(2): 345-352, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29529667

RESUMO

BACKGROUND: Two-stage reimplantation has consistently yielded high rates of success for patients with chronic prosthetic joint infection, although results more than 5 years after reimplantation are not commonly reported. Numerous factors may contribute to the risk of reinfection, although these factors-as well as the at-risk period after reimplantation-are not well characterized. QUESTIONS/PURPOSES: (1) What is the risk of reinfection after reimplantation for prosthetic joint infection at a minimum of 5 years? (2) Is the bacteriology of the index infection associated with late reinfection? (3) Is the presence of bacteria at the time of reimplantation associated with late reinfection? METHODS: Between 1995 and 2010, we performed 97 two-stage revisions in 93 patients for prosthetic joint infection of the hip or knee, and all are included in this retrospective study. During that time, the indications for this procedure generally were (1) infections occurring more than 3 months after the index arthroplasty; and (2) more acute infections associated with prosthetic loosening or resistant organisms. One patient (1%) was lost to followup; all others have a minimum of 5 years of followup (mean, 11 years; range, 5-20 years) and all living patients have been seen within the last 2 years. Patients were considered free from infection if they did not have pain at rest or constitutional symptoms such as fever, chills, or malaise. The patients' bacteriology and resistance patterns of these organisms were observed with respect to recurrence of infection. Odds ratios and Fisher's exact test were performed to analyze the data. The incidence of reinfection was determined using cumulative incidence methods that considered death as a competing event. RESULTS: Reinfection occurred in 12 of the 97 joints resulting in implant revision. The estimated 10-year cumulative incidence of infection was 14% (95% confidence interval [CI], 7%-23%) and incidence of infection from the same organism was 5% (95% CI, 1%-11%). Five occurred early or within 2 years and three were resistant pathogens (methicillin-resistant Staphylococcus aureus, methicillin-resistant Staphylococcus epidermidis, or vancomycin-resistant Enterococcus). Seven late hematogenous infections occurred and all were > 4 years after reimplantation and involved nonresistant organisms. Three of the five (60%) early infections were caused by resistant bacteria, whereas all seven late infections were caused by different organisms or a combination of different organisms than were isolated in the original infection. The early reinfections were more often caused by resistant organisms, whereas late infections involved different organisms than were isolated in the original infection and none involved resistant organisms. With the numbers available, we found no difference between patients in whom bacteria were detected at the time of reimplantation and those in whom cultures were negative in terms of the risk of reinfection 5 years after reimplantation (18.6% [18 of 97] versus 81.4% [79 of 97], odds ratio 1.56 [95% CI, 0.38-6.44]; p = 0.54); however, with only 93 patients, we may have been underpowered to make this analysis. CONCLUSIONS: In our study, resistant organisms were more often associated with early reinfection, whereas late failures were more commonly associated with new pathogens. We believe the most important finding in our study is that substantial risk of late infection remains even among patients who seemed free from infection 2 years after reimplantation for prosthetic joint infections of the hip or knee. This highlights the importance of educating our patients about the ongoing risk of prosthetic joint infection. LEVEL OF EVIDENCE: Level III, therapeutic study.


Assuntos
Artroplastia de Quadril/efeitos adversos , Artroplastia do Joelho/efeitos adversos , Prótese de Quadril/efeitos adversos , Prótese do Joelho/efeitos adversos , Infecções Relacionadas à Prótese/microbiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Farmacorresistência Bacteriana , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Nebraska/epidemiologia , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/cirurgia , Recidiva , Reoperação , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
2.
J Foot Ankle Surg ; 54(5): 830-5, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25960057

RESUMO

Given the high rates of wound complications with a standard lateral extensile incision, small dual incision techniques might result in less soft tissue destruction. The goal of the present study was to compare the biomechanical performance between a single locking plate and a dual locking plating system for an intra-articular calcaneal fracture model. A Sanders IIB type joint depression calcaneal fracture was created in 10 paired, fresh-frozen, cadaveric calcanei (age 47 ± 12, range 35 to 78 years). The calcanei of each pair were randomly assigned for fixation using either a lateral locking reconstruction plate or lateral and medial locking reconstruction plates. The specimens were axially loaded in cyclic fashion for 1000 cycles, followed by load to failure. The relative fragment movement was monitored optically in both the sagittal and the coronal planes. The amount of overall construct displacement increased with cycling, although no difference was found between the plating techniques. For fragment movement during cycling, the lateral joint fragment migrated anteroinferiorly along the fracture line relative to the tuberosity fragment for dual plated specimens by a small, but statistically significant, amount. This same translation was smaller for lateral plated specimens but was not found to be significant. During load to failure testing, no statistically significant differences were found for construct stiffness. A tendency was seen toward more interfragmentary motion in the sagittal plane (lateral joint fragment movement relative to the fracture line), with less movement overall in the coronal plane (anterior fragment translation and twist) for dual plating, although the difference from the lateral plate was not statistically significant. The present study demonstrated that for this calcaneal fracture model, the dual plating technique experienced a small amount of fragment translation during cycling that was significantly different statistically from that with lateral plating but was not clinically relevant. During the load to failure, the dual plating technique was comparable to the lateral plate. Thus, dual plating could be a viable biomechanical option for fracture reduction if avoidance of a large extensile lateral approach associated with lateral plating is warranted.


Assuntos
Placas Ósseas , Calcâneo/cirurgia , Fixação Interna de Fraturas/instrumentação , Fraturas Intra-Articulares/cirurgia , Adulto , Idoso , Articulação do Tornozelo/cirurgia , Fenômenos Biomecânicos , Cadáver , Calcâneo/lesões , Desenho de Equipamento , Segurança de Equipamentos , Fixação Interna de Fraturas/métodos , Fraturas Ósseas/cirurgia , Humanos , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Estresse Mecânico
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa