Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Nicotine Tob Res ; 25(7): 1291-1301, 2023 Jun 09.
Artigo em Inglês | MEDLINE | ID: mdl-36960777

RESUMO

INTRODUCTION: Tobacco smoking is a leading preventable cause of premature death globally. Urinary thiocyanate is a biomarker of cyanide exposure from tobacco smoke; however, few studies have evaluated its utility in diverse populations of smokers. AIMS AND METHODS: We examined the associations between urinary thiocyanate and self-reported never and current smokers among 1000 participants from 14 countries in the Prospective Urban and Rural Epidemiological study. We analyzed urinary thiocyanate in light and heavy smokers as compared to never-smokers from high- (HICs), middle- (MICs), and low-income countries (LICs) using a validated capillary electrophoresis method in conjunction with standardized questionnaires. RESULTS: The median urinary thiocyanate concentration was 31 µM, which ranged from 8.6 µM to 52 µM for never-smokers (n = 335) and current smokers (n = 660), respectively. Urinary thiocyanate was correlated with daily cigarette consumption (r = 0.621) and total nicotine equivalents (r = 0.514). Thiocyanate also displayed a better dose-response than urinary cotinine. A moderate association of urinary thiocyanate was found in biochemically verified never-smokers (r ~0.38) because of intake of vegetables, fruits, and dairy. Receiver-operating characteristic curves established cutoff values for urinary thiocyanate to differentiate current from never-smokers with an optimal threshold of 23.9 µM (Area Under the Curve or AUC = 0.861), which lowered progressively from HICs, MICs, and LICs. CONCLUSIONS: Elevated thiocyanate was evident in current smokers from high-income countries likely reflecting differences in smoking topography and greater toxicant burden. Background urinary thiocyanate in never-smokers was associated with goitrogenic food intake that obscured detection of secondhand smoke exposure. IMPLICATIONS: Urinary thiocyanate is a sensitive biomarker of active tobacco smoking relative to cotinine that can be measured by an inexpensive capillary electrophoresis assay. Regional cutoff values are demonstrated to improve discrimination of smoking status in developing countries because of differences in smoking habits and cigarette products consumed, as well as intake of goitrogenic foods. Urinary thiocyanate may allow for more reliable estimates of the hazards of tobacco smoking between countries with varying socioeconomic development as compared to self-reports.


Assuntos
Cotinina , Poluição por Fumaça de Tabaco , Humanos , Cotinina/análise , Tiocianatos/análise , Estudos Prospectivos , Poluição por Fumaça de Tabaco/efeitos adversos , Poluição por Fumaça de Tabaco/análise , Biomarcadores , Fumar Tabaco
2.
Anal Chem ; 92(19): 13558-13564, 2020 10 06.
Artigo em Inglês | MEDLINE | ID: mdl-32901481

RESUMO

Urinary 1-hydroxypyrene (HP) is a widely used biomarker of polycyclic aromatic hydrocarbon exposure relevant for biomonitoring the deleterious health impacts from tobacco smoke and ambient air pollution, as well as the hazards of certain occupations. Conventional methods for urinary HP analysis based on liquid chromatography with native fluorescence detection or tandem mass spectrometry (MS/MS) and gas chromatography-mass spectrometry (GC-MS) are limited by low sample throughput and complicated sample workup protocols that are prone to bias. Herein, we introduce a high throughput method to directly analyze the intact glucuronide conjugate of HP (HP-G) in human urine after a simple acidified ether extraction procedure when using multisegment injection-capillary electrophoresis-tandem mass spectrometry (MSI-CE-MS/MS). Multiplexed analyses of 13 independent urine extracts are achieved in a single run (<3 min/sample) with stringent quality control while avoiding enzyme deconjugation and precolumn chemical derivatization. Method validation demonstrates good technical precision (CV = 7.7%, n = 45) and accuracy with a mean recovery of (93 ± 3%) for urinary HP-G at three concentration levels with adequate detection limits (7 ng/L, S/N = 3). An interlaboratory method comparison of urine samples collected from firefighters deployed in the 2016 Fort McMurray wildfire also confirms good mutual agreement with an acceptable negative bias (mean bias = 15%, n = 55) when measuring urinary HP-G by MSI-CE-MS/MS as compared to total hydrolyzed urinary HP by GC-MS due to the low residual levels of free HP and its sulfate conjugate. This multiplexed separation platform is optimal for large-scale biomonitoring studies of air pollution relevant to global health as well as occupational smoke exposures in firefighters susceptible to dermal PAH absorption when using personal protective equipment.


Assuntos
Monitoramento Biológico , Glucuronatos/urina , Pirenos/urina , Poluição por Fumaça de Tabaco/análise , Fumar Tabaco/efeitos adversos , Eletroforese Capilar , Humanos , Estrutura Molecular , Espectrometria de Massas em Tandem
3.
Anal Bioanal Chem ; 411(7): 1397-1407, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30683964

RESUMO

Urinary 1-hydroxypyrene (OH-Pyr) is widely used for biomonitoring human exposures to polycyclic aromatic hydrocarbons (PAHs) from air pollution and tobacco smoke. However, there have been few rigorous validation studies reported to ensure reliable OH-Pyr determination for occupational health and risk assessment. Herein, we report an inter-laboratory method comparison for urinary OH-Pyr when using gas chromatography-high-resolution mass spectrometry (GC-HRMS) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) on urine specimens collected from firefighters (n = 42) deployed at the 2016 Fort McMurray wildfire. Overall, there was good mutual agreement in urinary OH-Pyr quantification following enzyme deconjugation with an average bias of 39% with no significant deviation from linearity (slope = 1.36; p > 0.05), whereas technical precision (< 12%) and average recovery (> 85%) were acceptable when using a stable-isotope internal standard. Faster analysis times (4 min) were achieved by LC-MS/MS without chemical derivatization, whereas lower detection limits (0.64 ng/L, S/N = 3) was realized with solid-phase extraction prior to GC-HRMS. A median creatinine normalized OH-Pyr concentration of 128 ng/g was measured for firefighters that were below the recommended biological exposure index due to delays between early stages of emergency firefighting and urine sample collection. Similar outcomes were also measured for 3-hydroxyphenanthrene and 9-hydroxyfluorene that were positively correlated with urinary OH-Pyr (p < 0.05), implying similar uptake, distribution, and liver biotransformation processes. Optimal specimen collection strategies post-deployment together with standardized protocols for OH-PAH analysis are critical to accurately evaluate smoke exposure in firefighters, including experimental conditions to ensure quantitative enzyme hydrolysis of urine samples. Graphical abstract.


Assuntos
Poluentes Ocupacionais do Ar/urina , Monitoramento Ambiental/métodos , Cromatografia Gasosa-Espectrometria de Massas/métodos , Pirenos/urina , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida/métodos , Bombeiros , Humanos , Exposição por Inalação/efeitos adversos , Exposição Ocupacional/efeitos adversos , Fumaça/efeitos adversos , Incêndios Florestais
4.
Anal Chem ; 88(21): 10710-10719, 2016 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-27677202

RESUMO

Capillary electrophoresis-mass spectrometry (CE-MS) represents a high efficiency microscale separation platform for untargeted profiling of polar/ionic metabolites that is ideal for volume-restricted biological specimens with minimal sample workup. Despite these advantages, the long-term stability of CE-MS remains a major obstacle hampering its widespread application in metabolomics notably for routine analysis of anionic metabolites under negative ion mode conditions. Herein, we report for the first time that commonly used ammonia containing buffers compatible with electrospray ionization (ESI)-MS can compromise the integrity of fused-silica capillaries via aminolysis of their outer polyimide coating. Unlike organic solvent swelling effects, this chemical process occurs under aqueous conditions that is dependent on ammonia concentration, buffer pH, and exposure time resulting in a higher incidence of capillary fractures and current errors during extended operation. Prevention of polyimide aminolysis is achieved by using weakly alkaline ammonia containing buffers (pH < 9) in order to preserve the tensile strength of the polyimide coated fused-silica capillary. Alternatively, less nucleophilic primary/secondary amines can be used as electrolytes without polyimide degradation, whereas chemically resistant polytetrafluoroethylene coating materials offer higher pH tolerance in ammonia. In this work, multisegment injection (MSI)-CE-MS was used as multiplexed separation platform for high throughput profiling of anionic metabolites when using optimized buffer conditions to prevent polyimide degradation. A diverse range of acidic metabolites in human urine were reliably measured by MSI-CE-MS via serial injection of seven urine samples within a single run, including organic acids, food-specific markers, microbial-derived compounds and over-the-counter drugs as their sulfate and glucuronide conjugates. This approach offers excellent throughput (<5 min/sample) and acceptable intermediate precision (average CV ≈ 16%) with high separation efficiency as reflected analysis of 30 anionic metabolites following 238 repeated sample injections of human urine over 3 days while using a single nonisotope internal standard for data normalization. Careful optimization and rigorous validation of CE-MS protocols are crucial for developing a rapid, low cost, and robust screening platform for metabolomics that is amenable to large-scale clinical and epidemiological studies.


Assuntos
Amônia/química , Ácidos Carboxílicos/urina , Eletroforese Capilar/instrumentação , Resinas Sintéticas/química , Soluções Tampão , Eletroforese Capilar/métodos , Humanos , Espectrometria de Massas/métodos
5.
Environ Sci Technol ; 49(23): 13862-7, 2015 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-26572321

RESUMO

The environmental occurrence of dechlorination moieties from the high production volume flame retardant, Dechlorane Plus (DP), has largely been documented; however, the sources have yet to be well understood. In addition, few laboratory-based studies exist which identify the cause for the occurrence of these chemicals in the environment or humans. Anaerobic dechlorination of the two DP isomers was investigated using a laboratory-simulated wastewater treatment plant (WWTP) environment where anaerobic digestion is used as part of the treatment regime. Known amounts of each isomer were added separately to sewage sludge which provided the electron-donating substrate and at prescribed time points in the incubation, a portion of the media was removed and analyzed for DP and any dechlorination metabolites. After 7 days, monohydrodechlorinated products were observed for both the syn- and anti-DP which were continued throughout the duration of our study (49 days) in an increasing manner giving a calculated formation rate of 0.48 ± 0.09 and 0.79 ± 0.12 pmols/day for syn- and anti-DP, respectively. Furthermore, we observed a second monohydrodechlorinated product only in the anti-DP isomer incubation medium. This strongly suggests that anti-DP is more susceptible to anaerobic degradation than the syn isomer. We also provide compelling evidence to the location of chlorine loss in the dechlorination DP analogues. Finally, the dechlorination DP moieties formed in our study matched the retention times and identification of those observed in surficial sediment located downstream of the WWTP.


Assuntos
Retardadores de Chama/metabolismo , Hidrocarbonetos Clorados/análise , Hidrocarbonetos Clorados/metabolismo , Compostos Policíclicos/análise , Compostos Policíclicos/metabolismo , Esgotos/microbiologia , Eliminação de Resíduos Líquidos/métodos , Poluentes Químicos da Água/metabolismo , Anaerobiose , Biodegradação Ambiental , Retardadores de Chama/análise , Sedimentos Geológicos/análise , Halogenação , Ontário , Águas Residuárias , Poluentes Químicos da Água/análise
6.
Sci Rep ; 13(1): 20065, 2023 11 16.
Artigo em Inglês | MEDLINE | ID: mdl-37973920

RESUMO

The vaginal microenvironment is key in mediating susceptibility to sexually transmitted infections. A polymicrobial environment with reduced Lactobacilllus spp. is characteristic of vaginal dysbiosis, associated with increased production of several short chain fatty acids (SCFAs), vaginal inflammation and an increased risk of HIV-1 acquisition. In contrast, a eubiotic vaginal microbiome (VMB), dominated by Lactobacillus spp. correlates with increased production of lactic acid (LA), an acidic milieu and protection against HIV-1. Vaginal metabolites, specifically LA and SCFAs including butyric, succinic and acetic acids are associated with modulation of HIV-1 risk. We assessed the impact of combined and individual SCFAs and LA on vaginal epithelial cells (VK2) grown in air-liquid interface cultures. Treatment of VK2 cells with eubiotic SCFA + LA mixture showed increased epithelial barrier integrity, reduced FITC dextran leakage and enhanced expression of cell-cell adhesion proteins. Treatment with dysbiotic SCFA + LA mixture diminished epithelial barrier integrity, increased NFκB activation and inflammatory mediators: TNF-α, IL-6, IL-8 and RANTES. LA was found to be the primary contributor of the beneficial effects. Eubiotic SCFA + LA mixture ameliorated HIV-1 mediated barrier disruption and HIV-1 leakage, whereas dysbiotic SCFA + LA treatment exacerbated HIV-1 effects. These findings indicate a key role for LA in future prophylactic strategies.


Assuntos
Soropositividade para HIV , HIV-1 , Feminino , Humanos , HIV-1/fisiologia , Ácido Láctico/farmacologia , Ácido Láctico/metabolismo , Disbiose , Vagina/metabolismo , Ácidos Graxos Voláteis/farmacologia , Ácidos Graxos Voláteis/metabolismo
7.
Am J Reprod Immunol ; 90(4): e13781, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37766408

RESUMO

BACKGROUND: The vaginal microbiome (VMB) is a critical determinant of reproductive health, where a microbial shift towards a dysbiotic environment has implications for susceptibility to, and clinical presentation of sexually transmitted infections (STIs). Metabolomic profiling of the vaginal microenvironment has led to the identification of metabolic responses to clinical conditions of dysbiosis. However, no studies have examined metabolic markers that are common across conditions and can serve as a signature for vaginal dysbiosis. METHOD OF STUDY: We have conducted a comprehensive systematic review and meta-analysis to identify consistently deregulated metabolites along with their impact on host and microbial metabolism during dysbiosis. We employed two complementary approaches including a vote counting analysis for all eligible studies identified in the systematic review, in addition to a meta-analysis for a subset of studies with sufficient available data. Significantly deregulated metabolites were then selected for pathway enrichment analysis. RESULTS: Our results revealed a total of 502 altered metabolites reported across 10 dysbiotic conditions from 16 studies. Following a rigorous, collective analysis, six metabolites which were consistently downregulated and could be generalized to all dysbiotic conditions were identified. In addition, five downregulated and one upregulated metabolite was identified from a bacterial vaginosis (BV) focused sub-analysis. These metabolites have the potential to serve as a metabolic signature for vaginal dysbiosis. Their role in eight altered metabolic pathways indicates a disruption of amino acid, carbohydrate, and energy metabolism during dysbiosis. CONCLUSION: Based on this analysis, we propose a schematic model outlining the common metabolic perturbations associated with vaginal dysbiosis, which can be potential targets for therapeutics and prophylaxis.

8.
J Cyst Fibros ; 22(1): 66-72, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35577746

RESUMO

Objectives Cystic fibrosis (CF) is a debilitating genetic disorder that benefits from early detection. CF diagnosis relies on measuring elevated sweat chloride that is difficult in neonates with low sweat rates. We introduce a new method for sweat chloride determination from volume-limited specimens, and explore the potential utility of sweat bicarbonate in neonatal CF screening. Methods A rapid assay (< 5 min) was developed to analyze chloride and bicarbonate using capillary electrophoresis with indirect UV detection (CE-iUV). Pilocarpine-stimulated sweat samples from screen-positive CF infants were collected at two hospital sites, including confirmed CF (n = 12), CF screen-positive inconclusive diagnosis (n = 4), and unaffected non-CF cases (n = 37). All sweat chloride samples were analyzed by a coulometric titrator and CE-iUV, and the viability to measure acid-labile bicarbonate was also evaluated. Results Stability studies revealed that bicarbonate can be reliably assessed in sweat if acidification and heating were avoided. Method validation demonstrated that sweat chloride and bicarbonate were quantified with acceptable accuracy (recovery of 102%), precision (CV = 3.7%) and detection limits (∼ 0.1 mM). An inter-laboratory comparison confirmed a mean bias of 6.5% (n = 53) for sweat chloride determination by CE-iUV relative to a commercial chloridometer. However, sweat bicarbonate did not discriminate between CF and non-CF infants (AUC = 0.623, p = 0.215) unlike chloride (AUC = 1.00, p = 3.00 × 10-7). Conclusions CE-iUV offers a robust method for sweat chloride testing from presumptive CF infants that may reduce testing failure rates. However, sweat bicarbonate does not have clinical value in newborn CF diagnosis.


Assuntos
Fibrose Cística , Recém-Nascido , Lactente , Humanos , Fibrose Cística/diagnóstico , Fibrose Cística/genética , Cloretos/análise , Bicarbonatos , Suor/química , Triagem Neonatal/métodos , Eletroforese Capilar/métodos
9.
Lancet Glob Health ; 10(2): e216-e226, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-35063112

RESUMO

BACKGROUND: Separate studies suggest that the risks from smoking might vary between high-income (HICs), middle-income (MICs), and low-income (LICs) countries, but this has not yet been systematically examined within a single study using standardised approaches. We examined the variations in risks from smoking across different country income groups and some of their potential reasons. METHODS: We analysed data from 134 909 participants from 21 countries followed up for a median of 11·3 years in the Prospective Urban Rural Epidemiology (PURE) cohort study; 9711 participants with myocardial infarction and 11 362 controls from 52 countries in the INTERHEART case-control study; and 11 580 participants with stroke and 11 331 controls from 32 countries in the INTERSTROKE case-control study. In PURE, all-cause mortality, major cardiovascular disease, cancers, respiratory diseases, and their composite were the primary outcomes for this analysis. Biochemical verification of urinary total nicotine equivalent was done in a substudy of 1000 participants in PURE. FINDINGS: In PURE, the adjusted hazard ratio (HR) for the composite outcome in current smokers (vs never smokers) was higher in HICs (HR 1·87, 95% CI 1·65-2·12) than in MICs (1·41, 1·34-1·49) and LICs (1·35, 1·25-1·46; interaction p<0·0001). Similar patterns were observed for each component of the composite outcome in PURE, myocardial infarction in INTERHEART, and stroke in INTERSTROKE. The median levels of tar, nicotine, and carbon monoxide displayed on the cigarette packs from PURE HICs were higher than those on the packs from MICs. In PURE, the proportion of never smokers reporting high second-hand smoke exposure (≥1 times/day) was 6·3% in HICs, 23·2% in MICs, and 14·0% in LICs. The adjusted geometric mean total nicotine equivalent was higher among current smokers in HICs (47·2 µM) than in MICs (31·1 µM) and LICs (25·2 µM; ANCOVA p<0·0001). By contrast, it was higher among never smokers in LICs (18·8 µM) and MICs (11·3 µM) than in HICs (5·0 µM; ANCOVA p=0·0001). INTERPRETATION: The variations in risks from smoking between country income groups are probably related to the higher exposure of tobacco-derived toxicants among smokers in HICs and higher rates of high second-hand smoke exposure among never smokers in MICs and LICs. FUNDING: Full funding sources are listed at the end of the paper (see Acknowledgments).


Assuntos
Países Desenvolvidos/estatística & dados numéricos , Países em Desenvolvimento/estatística & dados numéricos , Infarto do Miocárdio/epidemiologia , Acidente Vascular Cerebral/epidemiologia , Fumar Tabaco/epidemiologia , Adulto , Idoso , Monóxido de Carbono/análise , Doenças Cardiovasculares/epidemiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/mortalidade , Neoplasias/epidemiologia , Nicotina/análise , Estudos Prospectivos , Doenças Respiratórias/epidemiologia , Acidente Vascular Cerebral/mortalidade , Fumar Tabaco/efeitos adversos
10.
Nat Protoc ; 16(4): 1966-1994, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33674789

RESUMO

A standardized data workflow is described for large-scale serum metabolomic studies using multisegment injection-capillary electrophoresis-mass spectrometry. Multiplexed separations increase throughput (<4 min/sample) for quantitative determination of 66 polar/ionic metabolites in serum filtrates consistently detected (coefficient of variance (CV) <30%) with high frequency (>75%) from a multi-ethnic cohort of pregnant women (n = 1,004). We outline a validated protocol implemented in four batches over a 7-month period that includes details on preventive maintenance, sample workup, data preprocessing and metabolite authentication. We achieve stringent quality control (QC) and robust batch correction of long-term signal drift with good mutual agreement for a wide range of metabolites, including serum glucose as compared to a clinical chemistry analyzer (mean bias = 11%, n = 668). Control charts for a recovery standard (mean CV = 12%, n = 2,412) and serum metabolites in QC samples (median CV = 13%, n = 202) demonstrate acceptable intermediate precision with a median intraclass coefficient of 0.87. We also report reference intervals for 53 serum metabolites from a diverse population of women in their second trimester of pregnancy.


Assuntos
Eletroforese Capilar/métodos , Eletroforese Capilar/normas , Estudos Epidemiológicos , Ensaios de Triagem em Larga Escala/métodos , Metaboloma , Soro/metabolismo , Glicemia/metabolismo , Calibragem , Canadá , Estudos de Coortes , Jejum/sangue , Feminino , Humanos , Íons , Espectrometria de Massas , Metabolômica , Gravidez , Análise de Componente Principal , Controle de Qualidade , Padrões de Referência , Valores de Referência
11.
Ann Work Expo Health ; 63(4): 448-458, 2019 04 19.
Artigo em Inglês | MEDLINE | ID: mdl-30753267

RESUMO

BACKGROUND: In May 2016, firefighters from the province of Alberta, Canada deployed to a fire that engulfed the urban area of Fort McMurray. During the first days of the fire, firefighters experienced heavy smoke exposures during greatly extended work shifts. Urinary samples were collected post-deployment from three fire services for estimation of 1-hydroxypyrene (1-HP) concentration, reflecting exposure to polycyclic aromatic hydrocarbons (PAHs), to determine the effects of respiratory protective equipment (RPE) and skin hygiene in reducing internal dose. METHODS: Urine samples from one fire service (n = 62) were analyzed for 1-HP by two laboratories, using different assays (LC-MS/MS: GC-MS): remaining samples were analyzed just by LC-MS/MS. A Skin Exposure Mitigation Index (SEMI) was computed from questions on opportunities for changing clothing, showering, and washing during breaks. Regression analyses, using 1-HP ng/g creatinine as the dependent variable, assessed the effect of RPE and skin factors on PAH absorption, allowing for environmental exposure and potential confounders. Stratification identified key groups with equal delay in sample collection. RESULTS: 1-HP was detected in 71.0% of 62 samples by LC-MS/MS and 98.4% by GC-MS, with good mutual agreement between the methods. In 171 post-fire samples, 1-HP corrected for creatinine was related to current cigarette smoking and recent barbeque. Among those with samples collected within 48 h, urinary 1-HP was correlated with estimated exposure(r = 0.53, P < 0.001). In those with only one rotation before urine sample collection, no effect was seen of RPE use but I-HP was significantly lower (P = 0.003) in those with those with a high score on the SEMI scale, indicating better access to factors mitigating skin absorption. CONCLUSION: Skin exposure to PAHs is an important route of absorption in firefighters, which can be mitigated by good skin hygiene.


Assuntos
Poluentes Ocupacionais do Ar/urina , Bombeiros , Exposição Ocupacional/análise , Hidrocarbonetos Policíclicos Aromáticos/efeitos adversos , Pirenos/urina , Pele/química , Adulto , Cromatografia Líquida , Feminino , Cromatografia Gasosa-Espectrometria de Massas , Humanos , Higiene , Masculino , Pessoa de Meia-Idade , Exposição Ocupacional/prevenção & controle , Roupa de Proteção , Análise de Regressão , Absorção Cutânea , Espectrometria de Massas em Tandem , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa