Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 138
Filtrar
Mais filtros

País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
N Engl J Med ; 390(21): 1959-1971, 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38587261

RESUMO

BACKGROUND: Patients with severe aortic stenosis and a small aortic annulus are at risk for impaired valvular hemodynamic performance and associated adverse cardiovascular clinical outcomes after transcatheter aortic-valve replacement (TAVR). METHODS: We randomly assigned patients with symptomatic severe aortic stenosis and an aortic-valve annulus area of 430 mm2 or less in a 1:1 ratio to undergo TAVR with either a self-expanding supraannular valve or a balloon-expandable valve. The coprimary end points, each assessed through 12 months, were a composite of death, disabling stroke, or rehospitalization for heart failure (tested for noninferiority) and a composite end point measuring bioprosthetic-valve dysfunction (tested for superiority). RESULTS: A total of 716 patients were treated at 83 sites in 13 countries (mean age, 80 years; 87% women; mean Society of Thoracic Surgeons Predicted Risk of Mortality, 3.3%). The Kaplan-Meier estimate of the percentage of patients who died, had a disabling stroke, or were rehospitalized for heart failure through 12 months was 9.4% with the self-expanding valve and 10.6% with the balloon-expandable valve (difference, -1.2 percentage points; 90% confidence interval [CI], -4.9 to 2.5; P<0.001 for noninferiority). The Kaplan-Meier estimate of the percentage of patients with bioprosthetic-valve dysfunction through 12 months was 9.4% with the self-expanding valve and 41.6% with the balloon-expandable valve (difference, -32.2 percentage points; 95% CI, -38.7 to -25.6; P<0.001 for superiority). The aortic-valve mean gradient at 12 months was 7.7 mm Hg with the self-expanding valve and 15.7 mm Hg with the balloon-expandable valve, and the corresponding values for additional secondary end points through 12 months were as follows: mean effective orifice area, 1.99 cm2 and 1.50 cm2; percentage of patients with hemodynamic structural valve dysfunction, 3.5% and 32.8%; and percentage of women with bioprosthetic-valve dysfunction, 10.2% and 43.3% (all P<0.001). Moderate or severe prosthesis-patient mismatch at 30 days was found in 11.2% of the patients in the self-expanding valve group and 35.3% of those in the balloon-expandable valve group (P<0.001). Major safety end points appeared to be similar in the two groups. CONCLUSIONS: Among patients with severe aortic stenosis and a small aortic annulus who underwent TAVR, a self-expanding supraannular valve was noninferior to a balloon-expandable valve with respect to clinical outcomes and was superior with respect to bioprosthetic-valve dysfunction through 12 months. (Funded by Medtronic; SMART ClinicalTrials.gov number, NCT04722250.).


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Bioprótese/efeitos adversos , Insuficiência Cardíaca , Estimativa de Kaplan-Meier , Complicações Pós-Operatórias/etiologia , Desenho de Prótese , Falha de Prótese , Acidente Vascular Cerebral/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos
2.
Artigo em Inglês | MEDLINE | ID: mdl-38764317

RESUMO

BACKGROUND: Data using real-world assessments of aortic regurgitation (AR) severity to identify rates of Heart Valve Team evaluation and aortic valve replacement (AVR), as well as mortality among untreated patients, are lacking. The present study assessed these trends in care and outcomes for real-world patients with documented AR. METHODS: Using a deidentified data set (January 2018-March 2023) representing 1,002,853 patients >18 years of age from 25 US institutions participating in the egnite Database (egnite, Inc.) with appropriate permissions, patients were classified by AR severity in echocardiographic reports. Rates of evaluation by the Heart Valve Team, AVR, and all-cause mortality without AVR were examined using Kaplan-Meier estimates and compared using the log-rank test. RESULTS: Within the data set, 845,113 patients had AR severity documented. For moderate-to-severe or severe AR, respectively, 2-year rates (95% confidence interval) of evaluation by the Heart Valve Team (43.5% [41.7%-45.3%] and 65.4% [63.3%-67.4%]) and AVR (19.4% [17.6%-21.1%] and 46.5% [44.2%-48.8%]) were low. Mortality at 2 years without AVR increased with greater AR severity, up to 20.7% for severe AR (p < 0.001). In exploratory analyses, 2-year mortality for untreated patients with left ventricular end-systolic dimension index > 25 mm/m2 was similar for moderate (34.3% [29.2%-39.1%]) and severe (37.2% [24.9%-47.5%]) AR. CONCLUSIONS: Moderate or greater AR is associated with poor clinical outcomes among untreated patients at 2 years. Rates of Heart Valve Team evaluation and AVR were low for those with moderate or greater AR, suggesting that earlier referral to the Heart Valve Team could be beneficial.

3.
Curr Cardiol Rep ; 25(3): 89-95, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36787025

RESUMO

PURPOSE OF REVIEW: This review summarizes the current management of patients with newly diagnosed aortic stenosis. RECENT FINDINGS: Recent developments include detection of early myocardial dysfunction using serum B-type natriuretic peptide levels and global longitudinal strain, as well as ongoing trials of transcatheter aortic valve replacement in asymptomatic patients and patients with moderate aortic stenosis complicated by symptoms or left ventricular systolic dysfunction. Given the high mortality associated with severe symptomatic aortic stenosis, all symptomatic patients should be referred for aortic valve replacement. Asymptomatic patients with left ventricular systolic dysfunction, abnormal exercise stress test, high degree of stenosis, rapid disease progression, or elevated serum B-type natriuretic peptide level may also have an indication for valve replacement, based on established criteria. The progress in management of severe aortic stenosis has been in the direction of earlier detection and earlier valve replacement.


Assuntos
Estenose da Valva Aórtica , Disfunção Ventricular Esquerda , Humanos , Peptídeo Natriurético Encefálico , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Valva Aórtica/cirurgia , Medição de Risco , Índice de Gravidade de Doença
4.
Am Heart J ; 243: 92-102, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34587510

RESUMO

BACKGROUND: The SMall Annuli Randomized To Evolut or SAPIEN (SMART) Trial was designed to compare the performance of the two most widely available commercial transcatheter aortic valve replacement (TAVR) devices in patients with symptomatic severe native aortic stenosis with a small aortic valve annulus undergoing transfemoral TAVR. Patients with small aortic valve annuli are typically female and are often underrepresented in clinical trials. METHODS: The SMART Trial is an international, prospective, multi-center, randomized controlled, post-market trial. The trial will be conducted in approximately 700 subjects at approximately 90 sites globally. Inclusion criteria include severe aortic stenosis, aortic valve annulus area of ≤430 mm2 based on multi-detector computed tomography, and appropriate anatomy for both the Medtronic Evolut PRO/PRO+ self-expanding and Edwards SAPIEN 3/3 Ultra balloon-expandable devices. The primary clinical outcome composite endpoint is defined as mortality, disabling stroke or heart failure rehospitalization at 12 months. The co-primary valve function composite endpoint is defined as bioprosthetic valve dysfunction at 12 months which includes hemodynamic structural valve dysfunction, defined as a mean gradient ≥20 mmHg, non-structural valve dysfunction, defined as severe prothesis-patient mismatch or ≥moderate aortic regurgitation, thrombosis, endocarditis, and aortic valve re-intervention. Powered secondary endpoints will be assessed hierarchically. CONCLUSIONS: The SMART trial will be the largest head-to-head comparative trial of transfemoral TAVR using the two most widely available contemporary TAVR devices in the setting of small aortic annuli and the largest trial to enroll primarily women. CLINICAL TRIAL REGISTRATION: URL: www.clinicaltrials.gov, Unique identifier: NCT04722250.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Feminino , Humanos , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
5.
Catheter Cardiovasc Interv ; 98(4): E637-E646, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34004077

RESUMO

OBJECTIVES: We report the 30-day outcomes from the roll-in cohort of the CLASP IID trial, representing the first procedures performed by each site. BACKGROUND: The currently enrolling CLASP IID/IIF pivotal trial is a multicenter, prospective, randomized trial assessing the safety and effectiveness of the PASCAL transcatheter valve repair system in patients with clinically significant MR. The trial allows for up to three roll-in patients per site. METHODS: Eligibility criteria were: DMR ≥3+, prohibitive surgical risk, and deemed suitable for transcatheter repair by the local heart team. Trial oversight included a central screening committee and echocardiographic core laboratory. The primary safety endpoint was a 30-day composite MAE: cardiovascular mortality, stroke, myocardial infarction (MI), new need for renal replacement therapy, severe bleeding, and non-elective mitral valve re-intervention, adjudicated by an independent clinical events committee. Thirty-day echocardiographic, functional, and quality of life outcomes were assessed. RESULTS: A total of 45 roll-in patients with mean age of 83 years and 69% in NYHA class III/IV were treated. Successful implantation was achieved in 100%. The 30-day composite MAE rate was 8.9% including one cardiovascular death (2.2%) due to severe bleeding from a hemorrhagic stroke, one MI, and no need for re-intervention. MR≤1+ was achieved in 73% and ≤2+ in 98% of patients. 89% of patients were in NYHA class I/II (p < .001) with improvements in 6MWD (30 m; p = .054) and KCCQ (17 points; p < .001). CONCLUSIONS: Early results representing sites with first experience with the PASCAL repair system showed favorable 30-day outcomes in patients with DMR≥3+ at prohibitive surgical risk.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Idoso de 80 Anos ou mais , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Estudos Prospectivos , Qualidade de Vida , Resultado do Tratamento
6.
Curr Cardiol Rep ; 22(10): 120, 2020 08 09.
Artigo em Inglês | MEDLINE | ID: mdl-32772221

RESUMO

PURPOSE OF REVIEW: To describe the key role of the structural imager/interventional echocardiographer in transcatheter mitral valve therapies, particularly edge-to-edge repair. In addition, we review important recent advances in structural imaging and briefly describe several novel devices for transcatheter mitral valve repair. RECENT FINDINGS: Structural imagers represent a new subspecialty in cardiology and anesthesiology with specific skillset and training requirements. Their role is particularly important in imaging-based transcatheter interventions such as edge-to-edge mitral valve repair. This therapy has increasingly been used to treat primary (degenerative) mitral regurgitation when surgical risk is prohibitive and has recently been extended to patients with secondary (functional) mitral regurgitation. As novel transcatheter therapies continue to emerge, so do new multimodality imaging technologies. Structural imagers have become an integral part of the heart team. Their role is particularly visible in transcatheter mitral procedures. Rapidly developing transcatheter therapies have helped shape this new subspecialty and spark innovation in imaging technologies.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Cateterismo Cardíaco , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia
7.
Circulation ; 135(20): 1956-1976, 2017 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-28507251

RESUMO

Aortic stenosis is 1 of the most common heart valve diseases among adults. When symptoms develop, prognosis is poor, and current guidelines recommend prompt aortic valve replacement. Depending of the severity of the aortic stenosis and the presence of concomitant heart disease and medical comorbidities, stress testing represents a reasonable strategy to help better risk stratify asymptomatic patients. The present report provides a comprehensive review of the current available data on stress testing in aortic stenosis and subsequently summarizes its potential for guiding the optimal timing of aortic valve replacement.


Assuntos
Estenose da Valva Aórtica/diagnóstico , Doenças Assintomáticas , Tomada de Decisão Clínica/métodos , Teste de Esforço/métodos , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/terapia , Doenças Assintomáticas/terapia , Humanos
8.
Ethn Dis ; 25(2): 180-6, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26118146

RESUMO

BACKGROUND: Information regarding the prevalence and determinants of cardiac structure and function (systolic and diastolic) among the various Hispanic background groups in the United States is limited. METHODS AND RESULTS: The Echocardiographic Study of Latinos (ECHO-SOL) ancillary study recruited 1,824 participants through a stratified-sampling process representative of the population-based Hispanic Communities Health Study - Study of Latinos (HCHS-SOL) across four sites (Bronx, NY; Chicago, Ill; San Diego, Calif; Miami, Fla). The HCHS-SOL baseline cohort did not include an echo exam. ECHO-SOL added the echocardiographic assessment of cardiac structure and function to an array of existing HCHS-SOL baseline clinical, psychosocial, and socioeconomic data and provides sufficient statistical power for comparisons among the Hispanic subgroups. Standard two-dimensional (2D) echocardiography protocol, including M-mode, spectral, color and tissue Doppler study was performed. The main objectives were to: 1) characterize cardiac structure and function and its determinants among Hispanics and Hispanic subgroups; and 2) determine the contributions of specific psychosocial factors (acculturation and familismo) to cardiac structure and function among Hispanics. CONCLUSION: We describe the design, methods and rationale of currently the largest and most comprehensive study of cardiac structure and function exclusively among US Hispanics. ECHO-SOL aims to enhance our understanding of Hispanic cardiovascular health as well as help untangle the relative importance of Hispanic subgroup heterogeneity and sociocultural factors on cardiac structure and function.


Assuntos
Ecocardiografia , Cardiopatias/diagnóstico por imagem , Cardiopatias/etnologia , Hispânico ou Latino , Projetos de Pesquisa , Adolescente , Adulto , Idoso , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estados Unidos , Adulto Jovem
11.
Catheter Cardiovasc Interv ; 83(7): 1135-43, 2014 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-22815250

RESUMO

OBJECTIVE: The Coherex-EU Study evaluated the safety and efficacy of PFO closure utilizing novel in-tunnel PFO closure devices. BACKGROUND: Transcatheter closure of patent foramen ovale (PFO) followed the development of transcatheter closure devices designed to patch atrial septal defects (ASDs). The Coherex FlatStent™ and FlatStent™ EF devices were designed specifically to treat PFO anatomy. METHODS: A total of 95 patients with a clinical indication for PFO closure were enrolled in a prospective, multicenter first in man study at six clinical sites. Thirty-six patients received the first-generation FlatStent study device, and 57 patients received the second-generation FlatStent EF study device, which was modified based on clinical experience during the first 38 cases. Two patients enrolled to receive the first generation did not receive a device. RESULTS: At 6 months post-procedure, 45% (17/38) of the intention-to-treat (ITT) cohort receiving the first-generation FlatStent device had complete closure, 26% (10/38) had a trivial residual shunt, and 29% (11/38) had a moderate to large residual shunt. In the ITT cohort receiving the second-generation FlatStent EF device, 76% (43/57) had complete closure, 12% (7/57) had a trivial shunt, and 12% had a moderate to large shunt. Five major adverse events occurred, all without sequelae. CONCLUSION: This initial study of the Coherex FlatStent/FlatStent EF PFO Closure System demonstrated the potential for in-tunnel PFO closure. The in-tunnel Coherex FlatStent EF may offer an alternative to septal repair devices for PFO closure in appropriately selected patients; however, further investigation will be necessary to establish the best use of this device.


Assuntos
Cateterismo Cardíaco/métodos , Procedimentos Cirúrgicos Cardíacos/métodos , Forame Oval Patente/cirurgia , Dispositivo para Oclusão Septal , Stents , Adolescente , Adulto , Idoso , Ecocardiografia , Feminino , Seguimentos , Forame Oval Patente/diagnóstico , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Resultado do Tratamento , Adulto Jovem
13.
JACC Adv ; 3(5): 100959, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38939639

RESUMO

Background: The prognostic value of cardiac damage staging classification based on the extent of extravalvular damage has been proposed in moderate/severe aortic stenosis (AS). Objectives: The purpose of this study was to assess the association of cardiac damage staging with mortality across the spectrum of patients with AS following aortic surgical or transcatheter aortic valve replacement (AVR). Methods: We conducted a pooled meta-analysis of Kaplan-Meier-derived reconstructed time-to-event data from studies published through February 2023. Results: In total, 16 studies (n = 14,499) met our eligibility criteria and included 12,282 patients with symptomatic severe AS and 2,217 patients with asymptomatic severe/moderate AS. For patients with symptomatic severe AS, all-cause mortality was 24.0%, 27.7%, 38.0%, 56.3%, and 57.3% at 5 years in patients with cardiac damage stage 0, 1, 2, 3, and 4, respectively (stage 0 as reference; HR in stage 1: 1.30 [95% CI: 1.03-1.64]; P = 0.029; stage 2: 1.74 [95% CI: 1.41-2.16]; P < 0.001; stage 3: 2.92 [95% CI: 2.35-3.64]; P < 0.001, and stage 4: 3.51 [95% CI: 2.79-4.41]; P < 0.001). For patients with asymptomatic moderate/severe AS, all-cause mortality was 19.3%, 36.9%, 51.7%, and 67.8% at 8 years in patients with cardiac damage stage 0, 1, 2, and 3 to 4, respectively (HR in stage 1: 1.70 [95% CI: 1.21-2.38]; P = 0.002; stage 2: 2.20 [95% CI: 1.60-3.02]; P < 0.001; and stage 3 to 4: 3.90 [95% CI: 2.79-5.47]; P < 0.001). Conclusions: In patients undergoing AVR across the symptomatic and severity spectrum of AS, cardiac damage staging at baseline has important prognostic implications. This pooled meta-analysis in patients undergoing AVR suggests that staging of baseline cardiac damage could be considered for timing and selection of therapy in patients with moderate or severe AS to determine the need for earlier AVR or adjunctive pharmacotherapy to prevent irreversible cardiac damage and improve the long-term prognosis.

14.
Circ Cardiovasc Interv ; 17(2): e013298, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38235547

RESUMO

BACKGROUND: Frailty associates with worse outcomes after transcatheter aortic valve replacement (TAVR). Sarcopenia underlies frailty, but the association between a comprehensive assessment of sarcopenia-muscle mass, strength, and performance-and outcomes after TAVR has not been examined. METHODS: From a multicenter prospective registry of patients with symptomatic severe aortic stenosis undergoing TAVR, 445 who had a preprocedure computed tomography and clinical assessment of frailty were included. Cross-sectional muscle (psoas and paraspinal) areas were measured on computed tomography and indexed to height. Gait speed and handgrip strength were obtained, and patients were dichotomized into fast versus slow; strong versus weak; and normal versus low muscle mass. As measures of body composition, cross-sectional fat (subcutaneous and visceral) was measured and indexed to height. RESULTS: The frequency of patients who were slow, weak, and had low muscle mass was 56%, 59%, and 42%, respectively. Among the 3 components of sarcopenia, only slower gait speed (muscle performance) was independently associated with increased post-TAVR mortality (adjusted hazard ratio, 1.12 per 0.1 m/s decrease [95% CI, 1.04-1.21]; P=0.004; adjusted hazard ratio, 1.38 per 1 SD decrease [95% CI, 1.11-1.72]; P=0.004). Meeting multiple sarcopenia criteria was not associated with higher mortality risk than fewer. Lower indexed visceral fat area (adjusted hazard ratio, 1.48 per 1 SD decrease [95% CI, 1.15-1.89]; P=0.002) was associated with mortality but indexed subcutaneous fat was not. Death occurred in 169 (38%) patients. CONCLUSIONS: Among patients with symptomatic severe aortic stenosis and comprehensive sarcopenia and body composition phenotyping, gait speed was the only sarcopenia measure associated with post-TAVR mortality. Lower visceral fat was also associated with increased risk pointing to an obesity paradox also observed in other patient populations. These findings reinforce the clinical utility of gait speed as a measure of risk and a potential target for adjunctive interventions alongside TAVR to optimize clinical outcomes.


Assuntos
Estenose da Valva Aórtica , Fragilidade , Sarcopenia , Substituição da Valva Aórtica Transcateter , Humanos , Sarcopenia/diagnóstico por imagem , Sarcopenia/complicações , Fragilidade/diagnóstico , Fragilidade/complicações , Resultado do Tratamento , Força da Mão , Estudos Transversais , Medição de Risco , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Composição Corporal , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Fatores de Risco
15.
JACC Cardiovasc Imaging ; 17(5): 471-485, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38099912

RESUMO

BACKGROUND: The CLASP IID randomized trial (Edwards PASCAL TrAnScatheter Valve RePair System Pivotal Clinical Trial) demonstrated the safety and effectiveness of the PASCAL system for mitral transcatheter edge-to-edge repair (M-TEER) in patients at prohibitive surgical risk with significant symptomatic degenerative mitral regurgitation (DMR). OBJECTIVES: This study describes the echocardiographic methods and outcomes from the CLASP IID trial and analyzes baseline variables associated with residual mitral regurgitation (MR) ≤1+. METHODS: An independent echocardiographic core laboratory assessed echocardiographic parameters based on American Society of Echocardiography guidelines focusing on MR mechanism, severity, and feasibility of M-TEER. Factors associated with residual MR ≤1+ were identified using logistic regression. RESULTS: In 180 randomized patients, baseline echocardiographic parameters were well matched between the PASCAL (n = 117) and MitraClip (n = 63) groups, with flail leaflets present in 79.2% of patients. Baseline MR was 4+ in 76.4% and 3+ in 23.6% of patients. All patients achieved MR ≤2+ at discharge. The proportion of patients with MR ≤1+ was similar in both groups at discharge but diverged at 6 months, favoring PASCAL (83.7% vs 71.2%). Overall, patients with a smaller flail gap were significantly more likely to achieve MR ≤1+ at discharge (adjusted OR: 0.70; 95% CI: 0.50-0.99). Patients treated with PASCAL and those with a smaller flail gap were significantly more likely to sustain MR ≤1+ to 6 months (adjusted OR: 2.72 and 0.76; 95% CI: 1.08-6.89 and 0.60-0.98, respectively). CONCLUSIONS: The study used DMR-specific echocardiographic methodology for M-TEER reflecting current guidelines and advances in 3-dimensional echocardiography. Treatment with PASCAL and a smaller flail gap were significant factors in sustaining MR ≤1+ to 6 months. Results demonstrate that MR ≤1+ is an achievable benchmark for successful M-TEER. (Edwards PASCAL TrAnScatheter Valve RePair System Pivotal Clinical Trial [CLASP IID]; NCT03706833).


Assuntos
Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Valva Mitral , Valor Preditivo dos Testes , Recuperação de Função Fisiológica , Índice de Gravidade de Doença , Humanos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/fisiopatologia , Masculino , Feminino , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Valva Mitral/fisiopatologia , Resultado do Tratamento , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/efeitos adversos , Idoso , Fatores de Risco , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Fatores de Tempo , Idoso de 80 Anos ou mais , Próteses Valvulares Cardíacas , Estudos de Viabilidade , Medição de Risco , Desenho de Prótese , Ecocardiografia Tridimensional
16.
J Cardiovasc Magn Reson ; 15: 74, 2013 Aug 31.
Artigo em Inglês | MEDLINE | ID: mdl-24119924

RESUMO

BACKGROUND: The systolic variation of mitral regurgitation (MR) is a pitfall in its quantification. Current recommendations advocate using quantitative echocardiographic techniques that account for this systolic variation. While prior studies have qualitatively described patterns of systolic variation no study has quantified this variation. METHODS: This study includes 41 patients who underwent cardiovascular magnetic resonance (CMR) evaluation for the assessment of MR. Systole was divided into 3 equal parts: early, mid, and late. The MR jets were categorized as holosystolic, early, or late based on the portions of systole the jet was visible. The aortic flow and left ventricular stroke volume (LVSV) acquired by CMR were plotted against time. The instantaneous regurgitant rate was calculated for each third of systole as the difference between the LVSV and the aortic flow. RESULTS: The regurgitant rate varied widely with a 1.9-fold, 3.4-fold, and 1.6-fold difference between the lowest and highest rate in patients with early, late, and holosystolic jets respectively. There was overlap of peak regurgitant rates among patients with mild, moderate and severe MR. The greatest variation of regurgitant rate was seen among patients with mild MR. CONCLUSION: CMR can quantify the systolic temporal variation of MR. There is significant variation of the mitral regurgitant rate even among patients with holosystolic MR jets. These findings highlight the need to use quantitative measures of MR severity that take into consideration the temporal variation of MR.


Assuntos
Imagem Cinética por Ressonância Magnética , Insuficiência da Valva Mitral/diagnóstico , Valva Mitral/fisiopatologia , Adulto , Idoso , Feminino , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/fisiopatologia , Valor Preditivo dos Testes , Estudos Prospectivos , Índice de Gravidade de Doença , Volume Sistólico , Sístole , Fatores de Tempo , Função Ventricular Esquerda
17.
J Immunol ; 187(2): 1006-14, 2011 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-21677140

RESUMO

We sought to delineate further the immunological significance of T lymphocytes infiltrating the valve leaflets in calcific aortic stenosis (CAS) and determine whether there were associated alterations in circulating T cells. Using clonotypic TCR ß-chain length and sequence analysis we confirmed that the repertoire of tricuspid CAS valves contains numerous expanded T cell clones with varying degrees of additional polyclonality, which was greatest in cases with severe calcification. We now report a similar proportion of clonal expansions in the much younger bicuspid valve CAS cases. Peripheral blood flow cytometry revealed elevations in HLA-DR(+) activated CD8 cells and in the CD8(+)CD28(null)CD57(+) memory-effector subset that were significantly greater in both bicuspid and tricuspid CAS cases with more severe valve calcification. Lesser increases of CD4(+)CD28(null) T cells were identified, principally in cases with concurrent atherosclerotic disease. Upon immunostaining the CD8 T cells in all valves were mainly CD28(null), and CD8 T cell percentages were greatest in valves with oligoclonal repertoires. T cell clones identified by their clonotypic sequence as expanded in the valve were also found expanded in the circulating blood CD28(null)CD8(+) T cells and to a lesser degree in the CD8(+)CD28(+) subset, directly supporting the relationship between immunologic events in the blood and the valve. The results suggest that an ongoing systemic adaptive immune response is occurring in cases with bicuspid and tricuspid CAS, involving circulating CD8 T cell activation, clonal expansion, and differentiation to a memory-effector phenotype, with trafficking of T cells in expanded clones between blood and the valve.


Assuntos
Estenose da Valva Aórtica/imunologia , Calcinose/imunologia , Diferenciação Celular/imunologia , Memória Imunológica , Ativação Linfocitária/imunologia , Valva Mitral/imunologia , Subpopulações de Linfócitos T/imunologia , Valva Tricúspide/imunologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Envelhecimento/imunologia , Estenose da Valva Aórtica/metabolismo , Estenose da Valva Aórtica/patologia , Linfócitos T CD4-Positivos/imunologia , Linfócitos T CD4-Positivos/patologia , Linfócitos T CD8-Positivos/imunologia , Linfócitos T CD8-Positivos/patologia , Calcinose/metabolismo , Calcinose/patologia , Diferenciação Celular/genética , Movimento Celular/genética , Movimento Celular/imunologia , Células Clonais , Genes Codificadores da Cadeia beta de Receptores de Linfócitos T/imunologia , Humanos , Memória Imunológica/genética , Imunofenotipagem , Ativação Linfocitária/genética , Pessoa de Meia-Idade , Valva Mitral/metabolismo , Valva Mitral/patologia , Dados de Sequência Molecular , Subpopulações de Linfócitos T/metabolismo , Subpopulações de Linfócitos T/patologia , Valva Tricúspide/metabolismo , Valva Tricúspide/patologia
18.
Int J Cardiovasc Imaging ; 39(9): 1677-1685, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37347380

RESUMO

Although it is assumed that more severe MR is associated with a greater burden of symptoms and lower exercise capacity, the relationship between symptoms, exercise capacity, and mitral regurgitant severity has not been well studied. We prospectively studied 67 (63 ± 11 years, 72% male) patients with at least mild degenerative MR and left ventricular ejection fraction ≥ 50% who underwent stress echocardiography, CMR, and evaluation with the Kansas City Cardiomyopathy questionnaire (KCCQ). Symptoms and exercise capacity were evaluated in the context of MR severity. Patients reporting dyspnea had lower KCCQ symptom scores (79 ± 23 vs. 96 ± 9, p = 0.01) and achieved lower percentage of age and gender predicted METs (114 ± 37 vs. 152 ± 43%, p < 0.001) compared to those without dyspnea. There was no significant difference in MR volume between those with vs. without dyspnea by CMR (43 ± 26 ml vs. 51 ± 28 ml, p = 0.3) or echocardiography (64 ± 28 vs. 73 ± 41ml, p = 0.4). Those with severe MR by CMR had similar KCCQ symptom scores (96 ± 10 vs. 89 ± 17, p = 0.04) and percentage of age and gender predicted METs (148 ± 42 vs. 133 ± 47%, p = 0.2) to those without severe MR. Those with severe MR by echocardiography had similar KCCQ symptom score (93 ± 15 vs. 89 ± 16, p = 0.3) and percentage of age and gender predicted METs (138 ± 43 vs. 153 ± 46%, p = 0.2) to those without severe MR. Patients with degenerative MR assessed by CMR and stress echocardiography, there was no relationship between MR severity and either symptoms or exercise capacity. These findings highlight the disconnect between symptoms and the severity of MR and challenge the assumption that correcting MR can be counted on to improve symptom status in patients with degenerative MR.


Assuntos
Insuficiência da Valva Mitral , Humanos , Masculino , Feminino , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/complicações , Volume Sistólico , Função Ventricular Esquerda , Tolerância ao Exercício , Valor Preditivo dos Testes , Índice de Gravidade de Doença
19.
J Am Coll Cardiol ; 81(8): 743-752, 2023 02 28.
Artigo em Inglês | MEDLINE | ID: mdl-36813373

RESUMO

BACKGROUND: The extent of extravalvular cardiac damage is associated with increased risk of adverse events among patients with severe aortic stenosis undergoing aortic valve replacement (AVR). OBJECTIVES: The goal was to describe the association of cardiac damage on health status before and after AVR. METHODS: Patients from the PARTNER (Placement of Aortic Transcatheter Valves) 2 and 3 trials were pooled and classified by echocardiographic cardiac damage stage at baseline and 1 year as previously described (stage 0-4). We examined the association between baseline cardiac damage and 1-year health status (assessed by the Kansas City Cardiomyopathy Questionnaire Overall Score [KCCQ-OS]). RESULTS: Among 1,974 patients (794 surgical AVR, 1,180 transcatheter AVR), the extent of cardiac damage at baseline was associated with lower KCCQ scores both at baseline and at 1 year after AVR (P < 0.0001) and with increased rates of a poor outcome (death, KCCQ-OS <60, or a decrease in KCCQ-OS of ≥10 points) at 1 year (stages 0-4: 10.6% vs 19.6% vs 29.0% vs 44.7% vs 39.8%; P < 0.0001). In a multivariable model, each 1-stage increase in baseline cardiac damage was associated with a 24% increase in the odds of a poor outcome (95% CI: 9%-41%; P = 0.001). Change in stage of cardiac damage at 1 year after AVR was associated with the extent of improvement in KCCQ-OS over the same period (mean change in 1-year KCCQ-OS: improvement of ≥1 stage +26.8 [95% CI: 24.2-29.4] vs no change +21.4 [95% CI: 20.0-22.7] vs deterioration of ≥1 stage +17.5 [95% CI: 15.4-19.5]; P < 0.0001). CONCLUSIONS: The extent of cardiac damage before AVR has an important impact on health status outcomes, both cross-sectionally and after AVR. (PARTNER II Trial: Placement of AoRTic TraNscathetER Valves II - XT Intermediate and High Risk (PII A), NCT01314313; The PARTNER II Trial: Placement of AoRTic TraNscathetER Valves - PII B [PARTNERII B], NCT02184442; PARTNER 3 Trial: Safety and Effectiveness of the SAPIEN 3 Transcatheter Heart Valve in Low Risk Patients With Aortic Stenosis [P3], NCT02675114).


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/cirurgia , Qualidade de Vida , Resultado do Tratamento , Nível de Saúde , Estenose da Valva Aórtica/cirurgia , Fatores de Risco , Índice de Gravidade de Doença
20.
Circ Cardiovasc Interv ; 16(8): e012875, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37503662

RESUMO

BACKGROUND: Depression and cognitive dysfunction (CD) are not routinely screened for in patients before transcatheter aortic valve replacement (TAVR) and their association with postprocedural outcomes is poorly understood. The objectives of this study are to determine the prevalence of depression and CD in patients with aortic stenosis undergoing TAVR and evaluate their association with mortality and quality of life. METHODS: We analyzed a prospective, multicenter TAVR registry that systematically screened patients for preexisting depression and CD with the Patient Health Questionnaire-2 and Mini-Cog, respectively. The associations with mortality were assessed with Cox proportional hazard models and quality of life (Kansas City Cardiomyopathy Questionnaire and EuroQol visual analogue scale) were evaluated using multivariable ordinal regression models. RESULTS: A total of 884 patients were included; median follow-up was 2.88 years (interquartile range=1.2-3.7). At baseline, depression was observed in 19.6% and CD in 31.8%. In separate models, after adjustment, depression (HR, 1.45 [95% CI, 1.13-1.86]; P<0.01) and CD (HR, 1.27 [95% CI, 1.02-1.59]; P=0.04) were each associated with increased mortality. Combining depression and CD into a single model, mortality was greatest among those with both depression and CD (n=62; HR, 2.06 [CI, 1.44-2.96]; P<0.01). After adjustment, depression was associated with 6.6 (0.3-13.6) points lower on the Kansas City Cardiomyopathy Questionnaire 1-year post-TAVR and 6.7 (0.5-12.7) points lower on the EuroQol visual analogue scale. CD was only associated with lower EuroQol visual analogue scale. CONCLUSIONS: Depression and CD are common in patients that undergo TAVR and are associated with increased mortality and worse quality of life. Depression may be a modifiable therapeutic target to improve outcomes after TAVR.


Assuntos
Estenose da Valva Aórtica , Cardiomiopatias , Disfunção Cognitiva , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Qualidade de Vida , Estudos Prospectivos , Depressão/diagnóstico , Depressão/epidemiologia , Resultado do Tratamento , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/epidemiologia , Disfunção Cognitiva/diagnóstico , Disfunção Cognitiva/epidemiologia , Disfunção Cognitiva/etiologia , Assistência Centrada no Paciente , Cardiomiopatias/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa