Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Eur Radiol ; 27(6): 2464-2473, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27663227

RESUMO

OBJECTIVES: The purpose of this study was to demonstrate the feasibility of real-time fusion of coronary computed tomography angiography (CTA) centreline and arterial wall calcification with x-ray fluoroscopy during chronic total occlusion (CTO) percutaneous coronary intervention (PCI). METHODS: Patients undergoing CTO PCI were prospectively enrolled. Pre-procedural CT scans were integrated with conventional coronary fluoroscopy using prototype software. We enrolled 24 patients who underwent CTO PCI using the prototype CT fusion software, and 24 consecutive CTO PCI patients without CT guidance served as a control group. RESULTS: Mean age was 66 ± 11 years, and 43/48 patients were men. Real-time CTA fusion during CTO PCI provided additional information regarding coronary arterial calcification and tortuosity that generated new insights into antegrade wiring, antegrade dissection/reentry, and retrograde wiring during CTO PCI. Overall CTO success rates and procedural outcomes remained similar between the two groups, despite a trend toward higher complexity in the fusion CTA group. CONCLUSIONS: This study demonstrates that real-time automated co-registration of coronary CTA centreline and calcification onto live fluoroscopic images is feasible and provides new insights into CTO PCI, and in particular, antegrade dissection reentry-based CTO PCI. KEY POINTS: • Real-time semi-automated fusion of CTA/fluoroscopy is feasible during CTO PCI. • CTA fusion data can be toggled on/off as desired during CTO PCI • Real-time CT calcium and centreline overlay could benefit antegrade dissection/reentry-based CTO PCI.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Oclusão Coronária/diagnóstico por imagem , Intervenção Coronária Percutânea/métodos , Idoso , Estudos de Casos e Controles , Doença Crônica , Angiografia Coronária/métodos , Oclusão Coronária/cirurgia , Vasos Coronários/diagnóstico por imagem , Estudos de Viabilidade , Feminino , Fluoroscopia/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Imagem Multimodal/métodos , Projetos Piloto , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento , Calcificação Vascular/diagnóstico por imagem , Calcificação Vascular/cirurgia
2.
Pediatr Radiol ; 47(8): 963-973, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28474255

RESUMO

BACKGROUND: Navigational software provides real-time fluoroscopic needle guidance for percutaneous procedures in the Interventional Radiology (IR) suite. OBJECTIVE: We describe our experience with navigational software for pediatric percutaneous bone biopsies in the IR suite and compare technical success, diagnostic accuracy, radiation dose and procedure time with that of CT-guided biopsies. MATERIALS AND METHODS: Pediatric bone biopsies performed using navigational software (Syngo iGuide, Siemens Healthcare) from 2011 to 2016 were prospectively included and anatomically matched CT-guided bone biopsies from 2008 to 2016 were retrospectively reviewed with institutional review board approval. C-arm CT protocols used for navigational software-assisted cases included institution-developed low-dose (0.1/0.17 µGy/projection), regular-dose (0.36 µGy/projection), or a combination of low-dose/regular-dose protocols. Estimated effective radiation dose and procedure times were compared between software-assisted and CT-guided biopsies. RESULTS: Twenty-six patients (15 male; mean age: 10 years) underwent software-assisted biopsies (15 pelvic, 7 lumbar and 4 lower extremity) and 33 patients (13 male; mean age: 9 years) underwent CT-guided biopsies (22 pelvic, 7 lumbar and 4 lower extremity). Both modality biopsies resulted in a 100% technical success rate. Twenty-five of 26 (96%) software-assisted and 29/33 (88%) CT-guided biopsies were diagnostic. Overall, the effective radiation dose was significantly lower in software-assisted than CT-guided cases (3.0±3.4 vs. 6.6±7.7 mSv, P=0.02). The effective dose difference was most dramatic in software-assisted cases using low-dose C-arm CT (1.2±1.8 vs. 6.6±7.7 mSv, P=0.001) or combined low-dose/regular-dose C-arm CT (1.9±2.4 vs. 6.6±7.7 mSv, P=0.04), whereas effective dose was comparable in software-assisted cases using regular-dose C-arm CT (6.0±3.5 vs. 6.6±7.7 mSv, P=0.7). Mean procedure time was significantly lower for software-assisted cases (91±54 vs. 141±68 min, P=0.005). CONCLUSION: In our experience, navigational software technology in the IR suite is a promising alternative to CT guidance for pediatric bone biopsies providing comparable technical success and diagnostic accuracy with lower radiation dose and procedure time, in addition to providing real-time fluoroscopic needle guidance.


Assuntos
Doenças Ósseas/patologia , Biópsia Guiada por Imagem/métodos , Software , Tomografia Computadorizada por Raios X/métodos , Biópsia por Agulha , Criança , Feminino , Fluoroscopia , Humanos , Masculino , Estudos Prospectivos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Radiologia Intervencionista , Estudos Retrospectivos
3.
Pediatr Radiol ; 46(3): 413-21, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26681438

RESUMO

This technical innovation describes our experience using an X-ray magnetic resonance fusion (XMRF) software program to overlay 3-D MR images on real-time fluoroscopic images during sclerotherapy procedures for vascular malformations at a large pediatric institution. Five cases have been selected to illustrate the application and various clinical utilities of XMRF during sclerotherapy procedures as well as the technical limitations of this technique. The cases demonstrate how to use XMRF in the interventional suite to derive additional information to improve therapeutic confidence with regards to the extent of lesion filling and to guide clinical management in terms of intraprocedural interventional measures.


Assuntos
Angiografia por Ressonância Magnética/métodos , Radiografia Intervencionista/métodos , Tomografia Computadorizada por Raios X/métodos , Malformações Vasculares/diagnóstico por imagem , Malformações Vasculares/terapia , Adolescente , Criança , Pré-Escolar , Feminino , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Lactente , Recém-Nascido , Masculino , Modelos Biológicos , Modelos Estatísticos , Imagem Multimodal/métodos , Reconhecimento Automatizado de Padrão/métodos , Projetos Piloto , Reprodutibilidade dos Testes , Escleroterapia/métodos , Sensibilidade e Especificidade , Técnica de Subtração , Resultado do Tratamento
4.
J Surg Oncol ; 112(1): 18-25, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26031893

RESUMO

PURPOSE: To facilitate localization and resection of small lung nodules, we developed a prospective clinical trial (ClinicalTrials.gov number NCT01847209) for a novel surgical approach which combines placement of fiducials using intra-operative C-arm computed tomography (CT) guidance with standard thoracoscopic resection technique using image-guided video-assisted thoracoscopic surgery (iVATS). METHODS: Pretrial training was performed in a porcine model using C-arm CT and needle guidance software. Methodology and workflow for iVATS was developed, and a multi-modality team was trained. A prospective phase I-II clinical trial was initiated with the goal of recruiting eligible patients with small peripheral pulmonary nodules. Intra-operative C-arm CT scan was utilized for guidance of percutaneous marking with two T-bars (Kimberly-Clark, Roswell, GA) followed by VATS resection of the tumor. RESULTS: Twenty-five patients were enrolled; 23 underwent iVATS, one withdrew, and one lesion resolved. Size of lesions were: 0.6-1.8 cm, mean = 1.3 ± 0.38 cm.. All 23 patients underwent complete resection of their lesions. CT imaging of the resected specimens confirmed the removal of the T-bars and the nodule. Average and total procedure radiation dose was in the acceptable low range (median = 1501 µGy*m(2), range 665-16,326). There were no deaths, and all patients were discharged from the hospital (median length of stay = 4 days, range 2-12). Three patients had postoperative complications: one prolonged air-leak, one pneumonia, and one ileus. CONCLUSIONS: A successful and safe step-wise process has been established for iVATS, combining intra-operative C-arm CT scanning and thoracoscopic surgery in a hybrid operating room.


Assuntos
Neoplasias Pulmonares/cirurgia , Nódulos Pulmonares Múltiplos/cirurgia , Complicações Pós-Operatórias , Nódulo Pulmonar Solitário/cirurgia , Cirurgia Assistida por Computador/métodos , Cirurgia Torácica Vídeoassistida/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Cuidados Intraoperatórios , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Masculino , Pessoa de Meia-Idade , Nódulos Pulmonares Múltiplos/diagnóstico por imagem , Nódulos Pulmonares Múltiplos/patologia , Estadiamento de Neoplasias , Pneumonectomia , Prognóstico , Estudos Prospectivos , Radiografia Intervencionista , Nódulo Pulmonar Solitário/diagnóstico por imagem , Nódulo Pulmonar Solitário/patologia , Adulto Jovem
5.
Chest ; 158(3): e93-e97, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32892893

RESUMO

A subset of patients with coronavirus disease 2019 (COVID-19) and lung involvement pose a disposition challenge, particularly when hospital resources are constrained. Those not in respiratory failure are sent home, often with phone monitoring and/or respiratory rate and oxygen saturation monitoring. Hypoxemia may be a late presentation and is often preceded by abnormal lung findings on ultrasound. Early identification of pulmonary progression may preempt emergency hospitalization for respiratory decompensation and facilitate more timely admission. With the goal of safely isolating infected patients while providing advanced monitoring, we present a first report of patient self-performed lung ultrasound in the home with a hand-held device under the guidance of a physician using a novel teleguidance platform.


Assuntos
Betacoronavirus , Infecções por Coronavirus/diagnóstico , Serviços de Assistência Domiciliar , Pulmão/diagnóstico por imagem , Monitorização Fisiológica/métodos , Pneumonia Viral/diagnóstico , Ultrassonografia/métodos , Adulto , COVID-19 , Feminino , Humanos , Pandemias , SARS-CoV-2
6.
Med Phys ; 42(8): 4920-32, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26233218

RESUMO

PURPOSE: To propose new dose point measurement-based metrics to characterize the dose distributions and the mean dose from a single partial rotation of an automatic exposure control-enabled, C-arm-based, wide cone angle computed tomography system over a stationary, large, body-shaped phantom. METHODS: A small 0.6 cm(3) ion chamber (IC) was used to measure the radiation dose in an elliptical body-shaped phantom made of tissue-equivalent material. The IC was placed at 23 well-distributed holes in the central and peripheral regions of the phantom and dose was recorded for six acquisition protocols with different combinations of minimum kVp (109 and 125 kVp) and z-collimator aperture (full: 22.2 cm; medium: 14.0 cm; small: 8.4 cm). Monte Carlo (MC) simulations were carried out to generate complete 2D dose distributions in the central plane (z = 0). The MC model was validated at the 23 dose points against IC experimental data. The planar dose distributions were then estimated using subsets of the point dose measurements using two proposed methods: (1) the proximity-based weighting method (method 1) and (2) the dose point surface fitting method (method 2). Twenty-eight different dose point distributions with six different point number cases (4, 5, 6, 7, 14, and 23 dose points) were evaluated to determine the optimal number of dose points and their placement in the phantom. The performances of the methods were determined by comparing their results with those of the validated MC simulations. The performances of the methods in the presence of measurement uncertainties were evaluated. RESULTS: The 5-, 6-, and 7-point cases had differences below 2%, ranging from 1.0% to 1.7% for both methods, which is a performance comparable to that of the methods with a relatively large number of points, i.e., the 14- and 23-point cases. However, with the 4-point case, the performances of the two methods decreased sharply. Among the 4-, 5-, 6-, and 7-point cases, the 7-point case (1.0% [±0.6%] difference) and the 6-point case (0.7% [±0.6%] difference) performed best for method 1 and method 2, respectively. Moreover, method 2 demonstrated high-fidelity surface reconstruction with as few as 5 points, showing pixelwise absolute differences of 3.80 mGy (±0.32 mGy). Although the performance was shown to be sensitive to the phantom displacement from the isocenter, the performance changed by less than 2% for shifts up to 2 cm in the x- and y-axes in the central phantom plane. CONCLUSIONS: With as few as five points, method 1 and method 2 were able to compute the mean dose with reasonable accuracy, demonstrating differences of 1.7% (±1.2%) and 1.3% (±1.0%), respectively. A larger number of points do not necessarily guarantee better performance of the methods; optimal choice of point placement is necessary. The performance of the methods is sensitive to the alignment of the center of the body phantom relative to the isocenter. In body applications where dose distributions are important, method 2 is a better choice than method 1, as it reconstructs the dose surface with high fidelity, using as few as five points.


Assuntos
Tomografia Computadorizada de Feixe Cônico/instrumentação , Tomografia Computadorizada de Feixe Cônico/métodos , Imagens de Fantasmas , Radiometria/instrumentação , Radiometria/métodos , Simulação por Computador , Humanos , Modelos Biológicos , Método de Monte Carlo , Incerteza
7.
Invest Radiol ; 50(6): 384-91, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25635589

RESUMO

OBJECTIVES: Cardiac C-arm computed tomography (CT) uses a standard C-arm fluoroscopy system rotating around the patient to provide CT-like images during interventional procedures without moving the patient to a conventional CT scanner. We hypothesized that C-arm CT can be used to visualize and quantify the size of perfusion defects and late enhancement resulting from a myocardial infarction (MI) using contrast-enhanced techniques similar to previous CT and magnetic resonance imaging studies. MATERIALS AND METHODS: A balloon occlusion followed by reperfusion in a coronary artery was used to study acute and subacute MI in 12 swine. Electrocardiographically gated C-arm CT images were acquired the day of infarct creation (n = 6) or 4 weeks after infarct creation (n = 6). The images were acquired immediately after contrast injection, then at 1 minute, and every 5 minutes up to 30 minutes with no additional contrast. The volume of the infarct as measured on C-arm CT was compared against pathology. RESULTS: The volume of acute MI, visualized as a combined region of hyperenhancement with a hypoenhanced core, correlated well with pathologic staining (concordance correlation, 0.89; P < 0.0001; mean [SD] difference, 0.67 [2.98]cm3). The volume of subacute MI, visualized as a region of hyperenhancement, correlated well with pathologic staining at imaging times 5 to 15 minutes after contrast injection (concordance correlation, 0.82; P < 0.001; mean difference, -0.64 [1.94]cm3). CONCLUSIONS: C-arm CT visualization of acute and subacute MI is possible in a porcine model, but improvement in the imaging technique is important before clinical use. Visualization of MI in the catheterization laboratory may be possible and could provide 3-dimensional images for guidance during interventional procedures.


Assuntos
Meios de Contraste , Aumento da Imagem , Imagem por Ressonância Magnética Intervencionista , Infarto do Miocárdio/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Animais , Modelos Animais de Doenças , Feminino , Coração/diagnóstico por imagem , Suínos
8.
JACC Cardiovasc Imaging ; 4(3): 259-68, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21414574

RESUMO

OBJECTIVES: The purpose of this study was to evaluate use of cardiac C-arm computed tomography (CT) in the assessment of the dimensions and temporal characteristics of radiofrequency ablation (RFA) lesions. This imaging modality uses a standard C-arm fluoroscopy system rotating around the patient, providing CT-like images during the RFA procedure. BACKGROUND: Both cardiac magnetic resonance (CMR) and CT can be used to assess myocardial necrotic tissue. Several studies have reported visualizing cardiac RFA lesions with CMR; however, obtaining CMR images during interventional procedures is not common practice. Direct visualization of RFA lesions using C-arm CT during the procedure may improve outcomes and circumvent complications associated with cardiac ablation procedures. METHODS: RFA lesions were created on the endocardial surface of the left ventricle of 9 swine using a 7-F RFA catheter. An electrocardiographically gated C-arm CT imaging protocol was used to acquire projection images during iodine contrast injection and after the injection every 5 min for up to 30 min, with no additional contrast. Reconstructed images were analyzed offline. The mean and SD of the signal intensity of the lesion and normal myocardium were measured in all images in each time series. Lesion dimensions and area were measured and compared in pathologic specimens and C-arm CT images. RESULTS: All ablation lesions (n = 29) were visualized and lesion dimensions, as measured on C-arm CT, correlated well with postmortem tissue measurements (linear dimensions: concordance correlation = 0.87; area: concordance correlation = 0.90. Lesions were visualized as a perfusion defect on first-pass C-arm CT images with a signal intensity of 95 HU lower than that of normal myocardium (95% confidence interval: -111 HU to -79 HU). Images acquired at 1 and 5 min exhibited an enhancing ring surrounding the perfusion defect in 24 lesions (83%). CONCLUSIONS: RFA lesion size, including transmurality, can be assessed using electrocardiographically gated cardiac C-arm CT in the interventional suite. Visualization of RFA lesions using cardiac C-arm CT may facilitate the assessment of adequate lesion delivery and provide valuable feedback during cardiac ablation procedures.


Assuntos
Ablação por Cateter , Meios de Contraste , Ventrículos do Coração/cirurgia , Iohexol , Tomografia Computadorizada por Raios X/instrumentação , Animais , Desenho de Equipamento , Feminino , Ventrículos do Coração/diagnóstico por imagem , Necrose , Valor Preditivo dos Testes , Interpretação de Imagem Radiográfica Assistida por Computador , Análise de Regressão , Suínos , Fatores de Tempo
9.
Acad Radiol ; 18(7): 850-7, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21440465

RESUMO

RATIONALE AND OBJECTIVES: During radiofrequency catheter ablation for atrial fibrillation, the esophagus is at risk for thermal injury. In this study, C-arm computed tomography (CT) was compared to clinical CT, without the administration of oral contrast, to visualize the esophagus and its relationship to the left atrium and the ostia of the pulmonary veins (PVs) during the radiofrequency ablation procedure. MATERIALS AND METHODS: Sixteen subjects underwent both cardiac clinical CT and C-arm CT. Computed tomographic scans were performed on a multidetector scanner using a standard electrocardiographically gated protocol. C-arm computed tomographic scans were obtained using either a multisweep protocol with retrospective electrocardiographic gating or a non-gated single-sweep protocol. C-arm and clinical computed tomographic scans were analyzed in a random order and then compared for the following criteria: (1) visualization of the esophagus (yes or no), (2) relationship of esophageal position to the four PVs, and (3) direct contact or absence of a fat pad between the esophagus and the PV antrum. RESULTS: The esophagus was identified in all C-arm and clinical computed tomographic scans. In four cases, orthogonal planes were needed on C-arm CT (inferior PV level). In six patients, the esophageal location on C-arm CT was different from that on CT. Direct contact was reported in 19 of 64 of the segments (30%) examined on CT and in 26 of 64 (41%) on C-arm CT. In five of 64 segments (8%), C-arm CT overestimated a direct contact of the esophagus to the left atrium. CONCLUSIONS: C-arm computed tomographic image quality without the administration of oral contrast agents was shown to be sufficient for visualization of the esophagus location during a radiofrequency catheter ablation procedure for atrial fibrillation.


Assuntos
Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Esôfago/diagnóstico por imagem , Radiografia Intervencionista/métodos , Cirurgia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Feminino , Humanos , Imageamento Tridimensional/métodos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento
10.
J Am Soc Echocardiogr ; 20(10): 1203-10, 2007 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17588720

RESUMO

BACKGROUND: The accurate assessment of cardiac function in mice is challenging because of their small heart size and rapid heart rate. METHODS: We examined the usefulness of novel high-resolution echocardiography (HRE) with a 30-MHz transducer in evaluating cardiac function in 20 mice compared with conventional echocardiography (CE) with a 13-MHz transducer. The left ventricular (LV) regional wall motion (RWM), LV end-diastolic dimension, fractional shortening, anterior LV wall thickness, E/A, and myocardial performance index were assessed. RESULTS: RWM analysis was more feasible by HRE than by CE (P < .05). Interobserver agreement in RWM analysis and correlation in LV end-diastolic dimension, fractional shortening, anterior LV wall thickness, E/A, and myocardial performance index were all better with HRE than CE. CONCLUSIONS: HRE is superior to CE in assessing LV function in mice. HRE is potentially a useful method for accurate assessment of cardiac function in various mice models.


Assuntos
Ecocardiografia/métodos , Ventrículos do Coração/diagnóstico por imagem , Aumento da Imagem/métodos , Contração Miocárdica/fisiologia , Disfunção Ventricular Esquerda/fisiopatologia , Animais , Diástole , Modelos Animais de Doenças , Ventrículos do Coração/fisiopatologia , Masculino , Camundongos , Infarto do Miocárdio/complicações , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/fisiopatologia , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/etiologia
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa