1.
Radiology ; 310(2): e231956, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38376407

RESUMO

Background Coronary CT angiography is a first-line test in coronary artery disease but is limited by severe calcifications. Photon-counting-detector (PCD) CT improves spatial resolution. Purpose To investigate the effect of improved spatial resolution on coronary stenosis assessment and reclassification. Materials and Methods Coronary stenoses were evaluated prospectively in a vessel phantom (in vitro) containing two stenoses (25%, 50%), and retrospectively in patients (in vivo) who underwent ultrahigh-spatial-resolution cardiac PCD CT (from July 2022 to April 2023). Images were reconstructed at standard resolution (section thickness, 0.6 mm; increment, 0.4 mm; Bv44 kernel), high spatial resolution (section thickness, 0.4 mm; increment, 0.2 mm; Bv44 kernel), and ultrahigh spatial resolution (section thickness, 0.2; increment, 0.1 mm; Bv64 kernel). Percentages of diameter stenosis (DS) were compared between reconstructions. In vitro values were compared with the manufacturer specifications of the phantom and patient results were assessed regarding effects on Coronary Artery Disease Reporting and Data System (CAD-RADS) reclassification. Results The in vivo sample included 114 patients (mean age, 68 years ± 9 [SD]; 71 male patients). In vitro percentage DS measurements were more accurate with increasing spatial resolution for both 25% and 50% stenoses (mean bias for standard resolution, high spatial resolution, and ultrahigh spatial resolution, respectively: 10.1%, 8.0%, and 2.3%; P < .001). In vivo results confirmed decreasing median percentage DS with increasing spatial resolution for calcified stenoses (n = 161) (standard resolution, high spatial resolution, and ultrahigh spatial resolution, respectively: 41.5% [IQR, 27.3%-58.2%], 34.8% [IQR, 23.7%-55.1%], and 26.7% [IQR, 18.6%-44.3%]; P < .001), whereas noncalcified (n = 13) and mixed plaques (n = 19) did not show evidence of a difference (P ≥ .88). Ultrahigh-spatial-resolution reconstructions led to reclassification of 62 of 114 (54.4%) patients to lower CAD-RADS category than that assigned using standard resolution. Conclusion In vivo and in vitro coronary stenosis assessment improved for calcified stenoses by using ultrahigh-spatial-resolution PCD CT reconstructions, leading to lower percentage DS compared with standard resolution and clinically relevant rates of reclassification. © RSNA, 2024 Supplemental material is available for this article. See also the editorial by McCollough in this issue.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Humanos , Masculino , Idoso , Doença da Artéria Coronariana/diagnóstico por imagem , Constrição Patológica , Angiografia por Tomografia Computadorizada , Estudos Retrospectivos , Estenose Coronária/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Angiografia Coronária
2.
Eur Radiol ; 32(5): 3152-3160, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34950973

RESUMO

OBJECTIVES: In response to the COVID-19 pandemic, many researchers have developed artificial intelligence (AI) tools to differentiate COVID-19 pneumonia from other conditions in chest CT. However, in many cases, performance has not been clinically validated. The aim of this study was to evaluate the performance of commercial AI solutions in differentiating COVID-19 pneumonia from other lung conditions. METHODS: Four commercial AI solutions were evaluated on a dual-center clinical dataset consisting of 500 CT studies; COVID-19 pneumonia was microbiologically proven in 50 of these. Sensitivity, specificity, positive and negative predictive values, and AUC were calculated. In a subgroup analysis, the performance of the AI solutions in differentiating COVID-19 pneumonia from other conditions was evaluated in CT studies with ground-glass opacities (GGOs). RESULTS: Sensitivity and specificity ranges were 62-96% and 31-80%, respectively. Negative and positive predictive values ranged between 82-99% and 19-25%, respectively. AUC was in the range 0.54-0.79. In CT studies with GGO, sensitivity remained unchanged. However, specificity was lower, and ranged between 15 and 53%. AUC for studies with GGO was in the range 0.54-0.69. CONCLUSIONS: This study highlights the variable specificity and low positive predictive value of AI solutions in diagnosing COVID-19 pneumonia in chest CT. However, one solution yielded acceptable values for sensitivity. Thus, with further improvement, commercial AI solutions currently under development have the potential to be integrated as alert tools in clinical routine workflow. Randomized trials are needed to assess the true benefits and also potential harms of the use of AI in image analysis. KEY POINTS: • Commercial AI solutions achieved a sensitivity and specificity ranging from 62 to 96% and from 31 to 80%, respectively, in identifying patients suspicious for COVID-19 in a clinical dataset. • Sensitivity remained within the same range, while specificity was even lower in subgroup analysis of CT studies with ground-glass opacities, and interrater agreement between the commercial AI solutions was minimal to nonexistent. • Thus, commercial AI solutions have the potential to be integrated as alert tools for the detection of patients with lung changes suspicious for COVID-19 pneumonia in a clinical routine workflow, if further improvement is made.


Assuntos
COVID-19 , Inteligência Artificial , COVID-19/diagnóstico por imagem , Humanos , Pulmão/diagnóstico por imagem , Pandemias , Estudos Retrospectivos , SARS-CoV-2 , Tomografia Computadorizada por Raios X/métodos
3.
Liver Int ; 39(2): 324-331, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30318826

RESUMO

BACKGROUND & AIMS: Portal vein tumour thrombosis (PVTT) has a significant impact on the prognosis of patients with hepatocellular carcinoma (HCC). The degree of PVTT varies from sub-/segmental invasion to complete occlusion of the main trunk. Aim of this study was to evaluate whether the degree of PVTT correlates with prognosis. METHODS: A total of 1317 patients with HCC treated at our tertiary referral centre between January 2005 and December 2016 were included. PVTT was diagnosed by contrast-enhanced computed tomography or magnetic resonance imaging. The extent of PVTT was documented according to the Liver Cancer Study Group of Japan classification: Vp0 = no PVTT, Vp1 = segmental portal vein invasion, Vp2 = right anterior/posterior portal vein, Vp3 = right/left portal vein and Vp4 = main trunk. Median overall survival (OS) was calculated for each group. RESULTS: Portal vein tumour thrombosis was present in 484 (36.8%) patients. Median OS without PVTT was 35.7 months, significantly longer than in patients with PVTT (7.2 months, P < 0.001). The patients with PVTT were subclassified as follows: 103 Vp1, 87 Vp2, 143 Vp3 and 151 Vp4. The corresponding median OS yielded 14.6, 9.4, 5.8 and 4.8 months for Vp1-Vp4, respectively (P < 0.001). CONCLUSIONS: Portal vein tumour thrombosis in patients with HCC is associated with a dismal prognosis. The results indicate an association between the extent of PVTT and OS. However, the extent of PVTT is not that decisive, as even minor PVTT leads to a very poor prognosis. Therefore, meticulous evaluation of cross-sectional imaging is crucial for the clinical management of patients with HCC.


Assuntos
Carcinoma Hepatocelular/cirurgia , Hepatectomia/efeitos adversos , Neoplasias Hepáticas/cirurgia , Veia Porta/cirurgia , Trombose Venosa/cirurgia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma Hepatocelular/mortalidade , Carcinoma Hepatocelular/patologia , Feminino , Alemanha/epidemiologia , Humanos , Neoplasias Hepáticas/mortalidade , Neoplasias Hepáticas/patologia , Masculino , Pessoa de Meia-Idade , Veia Porta/patologia , Prognóstico , Estudos Retrospectivos , Análise de Sobrevida , Taxa de Sobrevida , Trombose Venosa/mortalidade , Trombose Venosa/patologia , Adulto Jovem
4.
Rofo ; 2024 May 28.
Artigo em Inglês, Alemão | MEDLINE | ID: mdl-38806150

RESUMO

Structured reporting (SR) not only offers advantages regarding report quality but, as an IT-based method, also the opportunity to aggregate and analyze large, highly structured datasets (data mining). In this study, a data mining algorithm was used to calculate epidemiological data and in-hospital prevalence statistics of pulmonary embolism (PE) by analyzing structured CT reports.All structured reports for PE CT scans from the last 5 years (n = 2790) were extracted from the SR database and analyzed. The prevalence of PE was calculated for the entire cohort and stratified by referral type and clinical referrer. Distributions of the manifestation of PEs (central, lobar, segmental, subsegmental, as well as left-sided, right-sided, bilateral) were calculated, and the occurrence of right heart strain was correlated with the manifestation.The prevalence of PE in the entire cohort was 24% (n = 678). The median age of PE patients was 71 years (IQR 58-80), and the sex distribution was 1.2/1 (M/F). Outpatients showed a lower prevalence of 23% compared to patients from regular wards (27%) and intensive care units (30%). Surgically referred patients had a higher prevalence than patients from internal medicine (34% vs. 22%). Patients with central and bilateral PEs had a significantly higher occurrence of right heart strain compared to patients with peripheral and unilateral embolisms.Data mining of structured reports is a simple method for obtaining prevalence statistics, epidemiological data, and the distribution of disease characteristics, as demonstrated by the PE use case. The generated data can be helpful for multiple purposes, such as for internal clinical quality assurance and scientific analyses. To benefit from this, consistent use of SR is required and is therefore recommended. · SR-based data mining allows simple epidemiologic analyses for PE.. · The prevalence of PE differs between outpatients and inpatients.. · Central and bilateral PEs have an increased risk of right heart strain.. · Jorg T, Halfmann MC, Graafen D et al. Structured reporting for efficient epidemiological and in-hospital prevalence analysis of pulmonary embolisms. Fortschr Röntgenstr 2024; DOI 10.1055/a-2301-3349.

5.
Rofo ; 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38749431

RESUMO

To evaluate the effect of a vendor-agnostic deep learning denoising (DLD) algorithm on diagnostic image quality of non-contrast cranial computed tomography (ncCT) across five CT scanners.This retrospective single-center study included ncCT data of 150 consecutive patients (30 for each of the five scanners) who had undergone routine imaging after minor head trauma. The images were reconstructed using filtered back projection (FBP) and a vendor-agnostic DLD method. Using a 4-point Likert scale, three readers performed a subjective evaluation assessing the following quality criteria: overall diagnostic image quality, image noise, gray matter-white matter differentiation (GM-WM), artifacts, sharpness, and diagnostic confidence. Objective analysis included evaluation of noise, contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR), and an artifact index for the posterior fossa.In subjective image quality assessment, DLD showed constantly superior results compared to FBP in all categories and for all scanners (p<0.05) across all readers. The objective image quality analysis showed significant improvement in noise, SNR, and CNR as well as for the artifact index using DLD for all scanners (p<0.001).The vendor-agnostic deep learning denoising algorithm provided significantly superior results in the subjective as well as in the objective analysis of ncCT images of patients with minor head trauma concerning all parameters compared to the FBP reconstruction. This effect has been observed in all five included scanners. · Significant improvement of image quality for 5 scanners due to the vendor-agnostic DLD. · Subjects were patients with routine imaging after minor head trauma. · Reduction of artifacts in the posterior fossa due to the DLD. · Access to improved image quality even for older scanners from different vendors. · Kapper C, Müller L, Kronfeld A et al. Value of vendor-agnostic deep learning image denoising in brain computed tomography: A multi-scanner study. Fortschr Röntgenstr 2024; DOI 10.1055/a-2290-4781.

6.
Clin Res Cardiol ; 113(4): 581-590, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38112742

RESUMO

BACKGROUND: Over the last few years, the concept of multidisciplinary pulmonary embolism response teams (PERTs) has emerged to encounter the increasing variety and complexity in managing acute pulmonary embolism (PE). PURPOSE: To investigate PERT's composition and added clinical value in a university center in Germany. METHODS: Over 4 years (01/2019-11/2022), patients with confirmed PE were enrolled in a prospective single-center cohort study (PERT Mainz). We investigated the composition of PERT and compared, after propensity score matching, patients with acute PE before and after the initiation of PERT at our Medical University Centre. The primary outcome was in-hospital PE-related mortality. RESULTS: From 2019 to 2022, 88 patients with acute PE with a PERT decision were registered. Of those, 13 (14.8%) patients died during the in-hospital stay. Patients evaluated by a PERT had a median age of 68; 48.9% were females, and 21.7% suffered from malignancy. Right ventricular dysfunction was present in 76.1% of all patients. In total, 42.0% were classified as intermediate-high-risk PE and 11.4% as high-risk PE. First PERT contact mainly originated from emergency departments (33.3%) and intensive care units (30.0%), followed by chest pain units (21.3%) and regular wards (12.0%). The participation rate of medical specialties demonstrated that cardiologists (100%) or cardiac/vascular surgeons (98.6%) were included in almost all PERT consultations, followed by radiologists (95.9%) and anesthesiologists (87.8%). Compared to the PERT era, more patients in the pre-PERT era were classified as simplified pulmonary embolism severity index (sPESI) ≥ 1 (78.4% vs 71.6%) and as high-risk PE according to ESC 2019 guidelines (18.2% vs. 11.4%). In the pre-PERT era, low- and intermediate-low patients with PE received more frequently advanced reperfusion therapies such as systemic thrombolysis or surgical embolectomy compared to the PERT era (10.7% vs. 2.5%). Patients in the pre-PERT were found to have a considerably higher all-cause mortality and PE-related mortality rate (31.8% vs. 14.8%) compared to patients in the PERT era (22.7% vs. 13.6%). After propensity matching (1:1) by including parameters as age, sex, sPESI, and ESC risk classes, univariate regression analyses demonstrated that the PE management based on a PERT decision was associated with lower risk of all-cause mortality (OR, 0.37 [95%CI 0.18-0.77]; p = 0.009). For PE-related mortality, a tendency for reduction was observed (OR, 0.54 [95%CI 0.24-1.18]; p = 0.121). CONCLUSION: PERT implementation was associated with a lower risk of all-cause mortality rate in patients with acute PE. Large prospective studies are needed further to explore the impact of PERTs on clinical outcomes.


Assuntos
Equipe de Assistência ao Paciente , Embolia Pulmonar , Feminino , Humanos , Masculino , Estudos Prospectivos , Estudos de Coortes , Embolia Pulmonar/diagnóstico , Embolia Pulmonar/epidemiologia , Embolia Pulmonar/terapia , Tempo de Internação , Terapia Trombolítica
7.
Eur J Radiol ; 176: 111517, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38805884

RESUMO

PURPOSE: To assess the impact of different quantum iterative reconstruction (QIR) levels on objective and subjective image quality of ultra-high resolution (UHR) coronary CT angiography (CCTA) images and to determine the effect of strength levels on stenosis quantification using photon-counting detector (PCD)-CT. METHOD: A dynamic vessel phantom containing two calcified lesions (25 % and 50 % stenosis) was scanned at heart rates of 60, 80 and 100 beats per minute with a PCD-CT system. In vivo CCTA examinations were performed in 102 patients. All scans were acquired in UHR mode (slice thickness0.2 mm) and reconstructed with four different QIR levels (1-4) using a sharp vascular kernel (Bv64). Image noise, signal-to-noise ratio (SNR), sharpness, and percent diameter stenosis (PDS) were quantified in the phantom, while noise, SNR, contrast-to-noise ratio (CNR), sharpness, and subjective quality metrics (noise, sharpness, overall image quality) were assessed in patient scans. RESULTS: Increasing QIR levels resulted in significantly lower objective image noise (in vitro and in vivo: both p < 0.001), higher SNR (both p < 0.001) and CNR (both p < 0.001). Sharpness and PDS values did not differ significantly among QIRs (all pairwise p > 0.008). Subjective noise of in vivo images significantly decreased with increasing QIR levels, resulting in significantly higher image quality scores at increasing QIR levels (all pairwise p < 0.001). Qualitative sharpness, on the other hand, did not differ across different levels of QIR (p = 0.15). CONCLUSIONS: The QIR algorithm may enhance the image quality of CCTA datasets without compromising image sharpness or accurate stenosis measurements, with the most prominent benefits at the highest strength level.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária , Estenose Coronária , Imagens de Fantasmas , Fótons , Razão Sinal-Ruído , Humanos , Angiografia por Tomografia Computadorizada/métodos , Masculino , Feminino , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Pessoa de Meia-Idade , Idoso , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Reprodutibilidade dos Testes , Algoritmos
8.
Cancer Imaging ; 23(1): 40, 2023 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-37098584

RESUMO

BACKGROUND: Clinically significant portal hypertension (CSPH) has been identified as an important prognostic factor in patients with hepatocellular carcinoma (HCC) undergoing curative treatment. This study aimed to assess PH estimates as prognostic factors in patients with HCC treated with immunotherapy. METHODS: All patients with HCC treated with an immunotherapeutic agent in first or subsequent lines at our tertiary care center between 2016 and 2021 were included (n = 50). CSPH was diagnosed using the established PH score for non-invasive PH estimation in pre-treatment CT data (cut-off ≥ 4). Influence of PH on overall survival (OS) and progression-free survival (PFS) was assessed in uni- and multivariable analyses. RESULTS: Based on the PH score, 26 patients (52.0%) were considered to have CSPH. After treatment initiation, patients with CSPH had a significantly impaired median OS (4.1 vs 33.3 months, p < 0.001) and a significantly impaired median PFS (2.7 vs 5.3 months, p = 0.02). In multivariable Cox regression, CSPH remained significantly associated with survival (HR 2.9, p = 0.015) when adjusted for established risk factors. CONCLUSIONS: Non-invasive assessment of CSPH using routine CT data yielded an independent prognostic factor in patients with HCC and immunotherapy. Therefore, it might function as an additional imaging biomarker to detect high-risk patients with poor survival and possibly for treatment decision making.


Assuntos
Carcinoma Hepatocelular , Hipertensão Portal , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/terapia , Prognóstico , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/terapia , Hipertensão Portal/diagnóstico por imagem , Hipertensão Portal/complicações , Imunoterapia , Tomografia Computadorizada por Raios X , Estudos Retrospectivos
9.
Diagnostics (Basel) ; 13(23)2023 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-38066763

RESUMO

Photon-counting detector computed tomography (PCD-CT) yields improved spatial resolution. The combined use of PCD-CT and a modern iterative reconstruction method, known as quantum iterative reconstruction (QIR), has the potential to significantly improve the quality of lung CT images. In this study, we aimed to analyze the impacts of different slice thicknesses and QIR levels on low-dose ultra-high-resolution (UHR) PCD-CT imaging of the lungs. Our study included 51 patients with different lung diseases who underwent unenhanced UHR-PCD-CT scans. Images were reconstructed using three different slice thicknesses (0.2, 0.4, and 1.0 mm) and three QIR levels (2-4). Noise levels were determined in all reconstructions. Three raters evaluated the delineation of anatomical structures and conspicuity of various pulmonary pathologies in the images compared to the clinical reference reconstruction (1.0 mm, QIR-3). The highest QIR level (QIR-4) yielded the best image quality. Reducing the slice thickness to 0.4 mm improved the delineation and conspicuity of pathologies. The 0.2 mm reconstructions exhibited lower image quality due to high image noise. In conclusion, the optimal reconstruction protocol for low-dose UHR-PCD-CT of the lungs includes a slice thickness of 0.4 mm, with the highest QIR level. This optimized protocol might improve the diagnostic accuracy and confidence of lung imaging.

10.
Cancer Imaging ; 23(1): 69, 2023 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-37480062

RESUMO

BACKGROUND: Excellent image quality is crucial for workup of hepatocellular carcinoma (HCC) in patients with liver cirrhosis because a signature tumor signal allows for non-invasive diagnosis without histologic proof. Photon-counting detector computed tomography (PCD-CT) can enhance abdominal image quality, especially in combination with a novel iterative reconstruction algorithm, quantum iterative reconstruction (QIR). The purpose of this study was to analyze the impact of different QIR levels on PCD-CT imaging of HCC in both phantom and patient scans. METHODS: Virtual monoenergetic images at 50 keV were reconstructed using filtered back projection and all available QIR levels (QIR 1-4). Objective image quality properties were investigated in phantom experiments. The study also included 44 patients with triple-phase liver PCD-CT scans of viable HCC lesions. Quantitative image analysis involved assessing the noise, contrast, and contrast-to-noise ratio of the lesions. Qualitative image analysis was performed by three raters evaluating noise, artifacts, lesion conspicuity, and overall image quality using a 5-point Likert scale. RESULTS: Noise power spectra in the phantom experiments showed increasing noise suppression with higher QIR levels without affecting the modulation transfer function. This pattern was confirmed in the in vivo scans, in which the lowest noise levels were found in QIR-4 reconstructions, with around a 50% reduction in median noise level compared with the filtered back projection images. As contrast does not change with QIR, QIR-4 also yielded the highest contrast-to-noise ratios. With increasing QIR levels, rater scores were significantly better for all qualitative image criteria (all p < .05). CONCLUSIONS: Without compromising image sharpness, the best image quality of iodine contrast optimized low-keV virtual monoenergetic images can be achieved using the highest QIR level to suppress noise. Using these settings as standard reconstruction for HCC in PCD-CT imaging might improve diagnostic accuracy and confidence.


Assuntos
Carcinoma Hepatocelular , Iodo , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Algoritmos
11.
Diagnostics (Basel) ; 13(11)2023 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-37296789

RESUMO

(1) Background: Photon-counting detector (PCD) CT offers a wide variety of kernels and sharpness levels for image reconstruction. The aim of this retrospective study was to determine optimal settings for coronary CT angiography (CCTA). (2) Methods: Thirty patients (eight female, mean age 63 ± 13 years) underwent PCD-CCTA in a high-pitch mode. Images were reconstructed using three different kernels and four sharpness levels (Br36/40/44/48, Bv36/40/44/48, and Qr36/40/44/48). To analyze objective image quality, the attenuation, image noise, contrast-to-noise ratio (CNR), and vessel sharpness were quantified in proximal and distal coronaries. For subjective image quality, two blinded readers assessed image noise, visually sharp reproduction of coronaries, and the overall image quality using a five-point Likert scale. (3) Results: Attenuation, image noise, CNR, and vessel sharpness significantly differed across kernels (all p < 0.001), with the Br-kernel reaching the highest attenuation. With increasing kernel sharpness, image noise and vessel sharpness increased, whereas CNR continuously decreased. Reconstruction with Br-kernel generally had the highest CNR (Br > Bv > Qr), except Bv-kernel had a superior CNR at sharpness level 40. Bv-kernel had significantly higher vessel sharpness than Br- and Qr-kernel (p < 0.001). Subjective image quality was rated best for kernels Bv40 and Bv36, followed by Br36 and Qr36. (4) Conclusion: Reconstructions with kernel Bv40 are beneficial to achieve optimal image quality in spectral high-pitch CCTA using PCD-CT.

12.
Infect Dis Rep ; 15(5): 635-641, 2023 Oct 18.
Artigo em Inglês | MEDLINE | ID: mdl-37888140

RESUMO

Cutibacterium acnes, an integral component of the skin's customary bacterial flora, represents a Gram-positive anaerobic bacterium characterized by its low virulence. Despite its low virulence, the pathogen can cause profound-seated infections as well as infections linked to medical devices. We report a case study of a prosthesis endocarditis accompanied by a paraaortic abscess caused by C. acnes, a development occurring five years prior to composite aortic root and valve replacement. At the point of admission, the patient presented with a combination of symptoms hinting at a subacute progression, such as weight loss, chest pain, and limitations of cardiopulmonary functionality. An anaerobic pathogen, namely C. acnes, was detected in a singular blood culture vial. Since first-line imaging modalities such as echocardiography did not reveal any signs of inflammation, and in the case of a suspected diagnosis for IE, did not show high pretest probability, further diagnostic imaging such as 18F-FDG PET CT was put to use. Here, a highly elevated glucose metabolism around the aortic valve ring was detected, pointing to an inflammatory process. The patient received adjusted intravenous antibiotic therapy over a course of six weeks; he then underwent surgical therapy via re-replacement of the aortic root and valve using a composite conduit. Advanced microbiological analyses, including the amplification of PCR and valve sequencing via 16S rDNA, mainly detected one pathogen: C. acnes. Delayed onset with mild symptoms and laboratory findings is characteristic of infective endocarditis by C. acnes. Due to its high rate of complications, mortality, and morbidity, an infection should not be disregarded as contamination. Recommendations from different studies underline a combination of a positive blood culture and microbiological evidence to differentiate between contamination and true infection in the case of an infection involving C. acnes. Serial blood cultures with prolonged incubation, advanced microbiological analyses, and modified Duke criteria including second-line imaging techniques should be utilized for further evaluation.

13.
J Thorac Imaging ; 37(5): 315-322, 2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-35699680

RESUMO

PURPOSE: Photon-counting detector computed tomography (PCD-CT) has the potential to significantly improve CT imaging in many ways including, but not limited to, low-dose high-resolution CT (HRCT) of the lung. The aim of this study was to perform an intrapatient comparison of the radiation dose and image quality of PCD-CT compared with conventional energy-integrating detector CT (EID-CT). METHODS: A total of 32 consecutive patients with available PCD-CT and EID-CT HRCT scans were included in the final analysis. The CT dose index (CTDI vol ) was extracted from patient dose reports. Qualitative image analysis comprised the lung parenchyma and mediastinal structures and was assessed by 3 readers using a 5-point Likert scale. Quantitative image analysis included assessment of noise and signal-to-noise ratio in the lung parenchyma, trachea, aorta, muscle, and background. RESULTS: The mean CTDI vol was 2.0 times higher in the conventional EID-CT scans (1.8±0.5 mGy) compared with PCD-CT (0.9±0.5 mGy, P <0.001). The overall image quality was rated significantly better by all 3 raters ( P <0.001) in the PCD-CT relative to the EID-CT. Quantitative analysis showed no significant differences in noise and signal-to-noise ratio in the lung parenchyma between PCD-CT and EID-CT. CONCLUSION: Compared with conventional EID-CT scans, PCD-CT demonstrated similar or better objective and subjective image quality at significantly reduced dose levels in an intrapatient comparison. These results and their effect on clinical decision-making should be further investigated in prospective studies.


Assuntos
Redução da Medicação , Fótons , Humanos , Imagens de Fantasmas , Estudos Prospectivos , Tomografia Computadorizada por Raios X/métodos
14.
Med Phys ; 36(7): 3099-106, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19673209

RESUMO

Quantification of myocardial blood flow (MBF) by means of T1-weighted first-pass magnetic resonance imaging (MRI) requires knowledge of the arterial input function (AIF), which is usually estimated from the left ventricle (LV). Dispersion of the contrast agent bolus may occur between the LV and the tissue of interest, which leads to systematic underestimation of the MBF. The aim of this study was to simulate the dispersion along a simplified coronary artery with different stenoses. To analyze the dispersion in vessels with typical dimensions of coronary arteries, simulations were performed using the computational fluid dynamics approach. Simulations were accomplished on straight vessels with integrated stenoses of different degrees of area reduction and length as well as two different shapes-an axial symmetric and an asymmetric. Two boundary conditions were used representing myocardial blood flow at rest and under hyperemic conditions. The results under steady boundary conditions show that the dispersion is more pronounced in resting condition than during hyperemia yielding an underestimation of the MBF around 15% in the resting state and around 8% under stress conditions. At the outlet of the vessel an axial symmetric stenosis results in increased dispersion whereas an asymmetric stenosis yields a reduction. Due to the more severe dispersion, resting MBF may be more underestimated in quantitative myocardial perfusion MRI studies compared with MBF under stress conditions. In consequence the myocardial perfusion reserve may be overestimated. The amount of systematic error depends in a complex way on the shape and degree of stenoses.


Assuntos
Angiografia Coronária/métodos , Circulação Coronária , Estenose Coronária/diagnóstico , Angiografia por Ressonância Magnética/métodos , Imagem de Perfusão do Miocárdio/métodos , Algoritmos , Velocidade do Fluxo Sanguíneo , Simulação por Computador , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/fisiopatologia , Hiperemia/diagnóstico , Hiperemia/diagnóstico por imagem , Hiperemia/fisiopatologia , Modelos Lineares , Modelos Biológicos , Estresse Fisiológico/fisiologia
15.
J Magn Reson ; 262: 68-72, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26754064

RESUMO

Hyperpolarization is a powerful tool to overcome the low sensitivity of nuclear magnetic resonance (NMR). However, applications are limited due to the short lifetime of this non equilibrium spin state caused by relaxation processes. This issue can be addressed by storing hyperpolarization in slowly decaying singlet spin states which was so far mostly demonstrated for non-proton spin pairs, e.g. (13)C-(13)C. Protons hyperpolarized by parahydrogen induced polarization (PHIP) in symmetrical molecules, are very well suited for this strategy because they naturally exhibit a long-lived singlet state. The conversion of the NMR silent singlet spin state to observable magnetization can be achieved by making use of singlet-triplet level anticrossings. In this study, a low-power radiofrequency pulse sequence is used for this purpose, which allows multiple successive singlet-triplet conversions. The generated magnetization is used to record proton images in a clinical magnetic resonance imaging (MRI) system, after 3min waiting time. Our results may open unprecedented opportunities to use the standard MRI nucleus (1)H for e.g. metabolic imaging in the future.


Assuntos
Hidrogênio/química , Imageamento por Ressonância Magnética/métodos , Campos Eletromagnéticos , Espectroscopia de Ressonância Magnética , Prótons , Ondas de Rádio , Compostos de Vinila/química
16.
Ann Biomed Eng ; 42(4): 787-96, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24281654

RESUMO

Myocardial blood flow (MBF) quantification using contrast-enhanced first-pass magnetic resonance imaging relies on the precise knowledge of the arterial input function (AIF). Due to vascular transport processes, however, the shape of the AIF may change from the left ventricle where the AIF is measured to the myocardium. We employed computational fluid dynamics simulations in a realistic model of the left circumflex artery to investigate the degree to which this effect corrupts MBF quantification. Different outlet boundary conditions were applied to examine their influence on the solution. Our results indicate that vascular transport processes in realistic coronary artery geometries give rise to non-negligible systematic errors in the MBF values. The magnitude of these errors differs considerably between the outlets of the 3D model. Moreover, outlet boundary conditions are shown to have a significant influence on the outflows at the outlets of the 3D model. In particular, the employed boundary conditions respond differently to an artificially inserted stenosis and to hyperemia condition. Finally, outlet boundary conditions are shown to have an influence on the resulting MBF value. Since MBF errors are different under rest and under hyperemia conditions, overestimation of myocardial perfusion reserve values may occur as well.


Assuntos
Circulação Coronária/fisiologia , Vasos Coronários/fisiologia , Modelos Cardiovasculares , Simulação por Computador , Meios de Contraste/administração & dosagem , Humanos , Hidrodinâmica , Hiperemia/fisiopatologia , Masculino , Descanso/fisiologia
17.
Comput Math Methods Med ; 2013: 513187, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23533541

RESUMO

Contrast-enhanced first-pass magnetic resonance imaging (MRI) in combination with a tracer kinetic model, for example, MMID4, can be used to determine myocardial blood flow (MBF) and myocardial perfusion reserve (MPR). Typically, the arterial input function (AIF) required for this methodology is estimated from the left ventricle (LV). Dispersion of the contrast agent bolus might occur between the LV and the myocardial tissue. Negligence of bolus dispersion could cause an error in MBF determination. The aim of this study was to investigate the influence of bolus dispersion in a simplified coronary bifurcation geometry including one healthy and one stenotic branch on the quantification of MBF and MPR. Computational fluid dynamics (CFD) simulations were combined with MMID4. Different inlet boundary conditions describing pulsatile and constant flows for rest and hyperemia and differing outflow conditions have been investigated. In the bifurcation region, the increase of the dispersion was smaller than inside the straight vessels. A systematic underestimation of MBF values up to -16.1% for pulsatile flow and an overestimation of MPR up to 7.5% were found. It was shown that, under the conditions considered in this study, bolus dispersion can significantly influence the results of quantitative myocardial MR-perfusion measurements.


Assuntos
Constrição Patológica/patologia , Meios de Contraste/farmacologia , Circulação Coronária/fisiologia , Vasos Coronários/anatomia & histologia , Coração/fisiologia , Hidrodinâmica , Imageamento por Ressonância Magnética/métodos , Algoritmos , Velocidade do Fluxo Sanguíneo , Simulação por Computador , Diagnóstico por Imagem/métodos , Humanos , Processamento de Imagem Assistida por Computador , Modelos Moleculares , Miocárdio/patologia , Perfusão , Fluxo Pulsátil , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/métodos
18.
Phys Med Biol ; 56(16): 5167-85, 2011 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-21775789

RESUMO

Myocardial blood flow (MBF) can be quantified using T1-weighted first-pass magnetic resonance imaging (MRI) in combination with a tracer-kinetic model, like MMID4. This procedure requires the knowledge of an arterial input function which is usually estimated from the left ventricle (LV). Dispersion of the contrast agent bolus may occur between the LV and the tissue of interest. The aim of this study was to investigate the dispersion under conditions of physiological pulsatile blood flow, and to simulate its effect on MBF quantification. The dispersion was simulated in coronary arteries using a computational fluid dynamics (CFD) approach. Simulations were accomplished on straight vessels with stenosis of different degrees and shapes. The results show that dispersion is more pronounced under resting conditions than during hyperemia. Stenosis leads to a reduction of dispersion. In consequence, dispersion results in a systematic MBF underestimation between -0.4% and -9.3%. The relative MBF error depends not only on the dispersion but also on the actual MBF itself. Since MBF under rest is more underestimated than under stress, myocardial perfusion reserve is overestimated between 0.1% and 4.5%. Considering other sources of errors in myocardial perfusion MRI, systematic errors of MBF by bolus dispersion are relatively small.


Assuntos
Meios de Contraste , Imageamento por Ressonância Magnética/métodos , Imagem de Perfusão do Miocárdio/métodos , Fluxo Pulsátil , Circulação Coronária , Difusão , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa