Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Int J Mol Med ; 20(5): 683-7, 2007 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17912461

RESUMO

Plasminogen activator inhibitor-1 (PAI-1) is the major specific inhibitor of tissue-type plasminogen activator (tPA) which mediates fibrin clot lysis through activation of plasminogen. Wild-type-PAI-1 (wPAI-1) is rapidly converted to the latent form (half-life of approximately 2 h) and loses its ability to inhibit tPA. We developed a very long half-life PAI-1 (VLHL PAI-1), a recombinant protein with a half-life >700 h compared with wPAI-1. In this study, VLHL PAI-1 was assessed for its ability to inhibit clot lysis in vitro. Clot formation was initiated in normal plasma supplemented with tPA by the addition of either tissue factor or human recombinant FVIIa. Clot lysis time, monitored turbidimetrically in a microtiter plate reader, was determined at various concentrations of wPAI-1 and VLHL PAI-1. Both wPAI-1 and VLHL PAI-1 caused a significant increase in clot lysis time, although the latter was somewhat less effective at lower concentrations. The VLHL PAI-1, but not wPAI-1, maintained its anti-fibrinolytic activity after preincubation overnight at 37 degrees. These studies demonstrate that VLHL PAI-1 is an effective inhibitor of fibrin clot degradation. Due to the high stability of VLHL PAI-1 compared with wPAI-1, this novel inhibitor of tPA-mediated fibrinolysis may have therapeutic applications for treating surgical and trauma patients when used directly or in conjunction with the procoagulant recombinant FVIIa.


Assuntos
Coagulação Sanguínea/efeitos dos fármacos , Fibrina/metabolismo , Fibrinólise/efeitos dos fármacos , Inibidor 1 de Ativador de Plasminogênio/farmacologia , Proteínas Recombinantes/farmacologia , Ativador de Plasminogênio Tecidual/farmacologia , Eletroforese em Gel de Poliacrilamida , Meia-Vida , Humanos , Inibidor 1 de Ativador de Plasminogênio/isolamento & purificação , Espectrofotometria , Termodinâmica
2.
Assay Drug Dev Technol ; 12(5): 293-302, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24846303

RESUMO

The emergence of sphingosine-1-phosphate lyase (SPL) as a promising therapeutic target for inflammatory diseases has heightened interest in the identification of small molecules that modulate its activity. The enzymatic activity of SPL is typically measured using radiometric or fluorescence-based assays that require a lipid extraction step, or by direct quantitation of reaction products using mass spectrometry (MS). To facilitate testing large numbers of compounds to identify SPL modulators, we developed a robust scintillation proximity assay (SPA) that is compatible with high-throughput screening (HTS). This assay employs recombinant human full-length SPL in insect cell membrane preparations to catalyze the conversion of biotinylated aminosphingosine-1-[(33)P]phosphate (S1(33)P-biotin) to trans-2-hexadecenal-biotin and ethanolamine [(33)P]phosphate. To validate the SPA and confirm the fidelity of its measurement of SPL enzyme activity, we developed a Rapid-Fire MS method that quantitates nonradiolabeled S1P-biotin. In addition, we developed a simple, scalable method to produce S1(33)P-biotin in quantities sufficient for HTS. The optimized SPA screen in 384-well microplates produced a mean plate-wise Z'-statistic of 0.58 across approximately 3,000 plates and identified several distinct structural classes of SPL inhibitor. Among the inhibitors that the screen identified was one compound with an IC50 of 1.6 µM in the SPA that induced dose-dependent lymphopenia in mice.


Assuntos
Aldeído Liases/antagonistas & inibidores , Inibidores Enzimáticos/farmacologia , Ensaios de Triagem em Larga Escala , Contagem de Cintilação , Aldeído Liases/metabolismo , Animais , Biocatálise/efeitos dos fármacos , Relação Dose-Resposta a Droga , Ativação Enzimática/efeitos dos fármacos , Inibidores Enzimáticos/química , Humanos , Linfopenia/tratamento farmacológico , Linfopenia/enzimologia , Linfopenia/metabolismo , Espectrometria de Massas , Camundongos , Estrutura Molecular , Proteínas Recombinantes/metabolismo , Relação Estrutura-Atividade
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa