Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Ultraschall Med ; 40(4): 495-503, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31137050

RESUMO

PURPOSE: To evaluate the diagnostic performance of strain ratio elastography (SRE) and shear wave elastography (SWE) alone and in combination with Thyroid Imaging Reporting and Data System (TIRADS) classification parameters to improve differentiation between benign and malignant thyroid nodules. MATERIALS AND METHODS: In this prospective study benign (n = 191) and malignant (n = 52) thyroid nodules were examined with high-resolution ultrasound (US) features using the TIRADS lexicon and SRE semiquantitative and SWE quantitative findings using histology or cytology as the gold standard with a 12-month follow-up. Sensitivity (Se), specificity (Sp) and the area under the ROC curve (AUROC) were used to evaluate the diagnostic performance of each feature and combinations of the methods. RESULTS: TIRADS score showed a sensitivity of 59.6 %, a specificity of 83.8 % with an AUROC of 0.717, a PPV of 50.0 % and an NPV of 88.4 %. SRE yielded the highest performance with a sensitivity of 82.7 %, a specificity of 92.7 % with AUROC of 0.877, a PPV 75.4 % and an NPV of 95.2 %. SWE (kPa) had a sensitivity and specificity of 67.3 % and 82.7 %, respectively, with an AUROC of 0.750, a PPV of 51.5 % and an NPV of 90.3 %. Differences were significant for SRE only but not for SWE. CONCLUSION: Ultrasound elastography may improve thyroid nodule discrimination. In particular, SRE has a better performance than TIRADS classification, while their combination improves sensitivity.


Assuntos
Técnicas de Imagem por Elasticidade , Nódulo da Glândula Tireoide , Sistemas de Dados , Humanos , Estudos Prospectivos , Sensibilidade e Especificidade , Nódulo da Glândula Tireoide/classificação , Nódulo da Glândula Tireoide/diagnóstico por imagem
2.
Eur Radiol ; 26(5): 1441-9, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26337431

RESUMO

OBJECTIVES: To assess whether ultrasound elastography (USE) with strain ratio increases diagnostic accuracy of Doppler ultrasound in further characterisation of cytologically Thy3 thyroid nodules. METHODS: In two different university diagnostic centres, 315 patients with indeterminate cytology (Thy3) in thyroid nodules aspirates were prospectively evaluated with Doppler ultrasound and strain ratio USE before surgery. Ultrasonographic features were analysed separately and together as ultrasound score, to assess sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV). Receiver operating characteristic (ROC) curves to identify optimal cut-off value of the strain ratio were also provided. Diagnosis on a surgical specimen was considered the standard of reference. RESULTS: Higher strain ratio values were found in malignant nodules, with an optimum strain ratio cut-off of 2.09 at ROC analysis. USE with strain ratio showed 90.6% sensitivity, 93% specificity, 82.8% PPV, 96.4% NPV, while US score yielded a sensitivity of 52.9%, specificity of 84.3%, PPV 55.6% and NPV 82.9%. The diagnostic gain with strain ratio was statistically significant as proved by ROC areas, which was 0.9182 for strain ratio and 0.6864 for US score. CONCLUSIONS: USE with strain ratio should be considered a useful additional tool to colour-Doppler US, since it improves characterisation of thyroid nodules with indeterminate cytology. KEY POINTS: • Strain ratio measurements improve differentiation of thyroid nodules with indeterminate cytology • Elastography with strain ratio is more reliable than ultrasound features and ultrasound score • Strain ratio may help to better select patients with Thy 3 nodules candidate for surgery.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Nódulo da Glândula Tireoide/diagnóstico por imagem , Ultrassonografia Doppler em Cores/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Curva ROC , Sensibilidade e Especificidade , Adulto Jovem
3.
Eur Radiol ; 24(1): 143-50, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23979108

RESUMO

OBJECTIVE: Evaluation of the diagnostic efficacy and interobserver agreement of Q-elastography in the differentiation of benign from malignant thyroid nodules. METHODS: A total of 344 thyroid nodules in 288 patients were examined with grey-scale and colour Doppler ultrasound (CDUS) and Q-elastography by two independent operators. Nodules with hypoechogenicity, poorly defined margins, microcalcifications, and intralesional vascularity were classified as suspicious. Diagnostic performances of CDUS features and Q-elastography for predicting thyroid malignancy were estimated using ROC analysis. Cytology or histopathology was the reference standard. Interobserver agreement in the evaluation of CDUS and Q-elastography was assessed using Cohen's k-statistic. RESULTS: Q-elastography showed excellent diagnostic performance for the prediction of thyroid malignancy, with sensitivity of 93 % and specificity of 92 % for operator 1 (best cutoff at 2.02), and sensitivity of 84 % and specificity of 79 % for operator 2 (best cutoff at 1.86). Performance of Q-elastography was superior to that of CDUS. Reproducibility of the findings was excellent for both Q-elastography and CDUS features as assessed with Cohen's k, which was highest for strain ratio measurements (0.95) and lowest for the echogenicity score (0.83). CONCLUSIONS: Q-elastography showed excellent performance. It is a valid and reproducible diagnostic method as well as a promising tool for identifying suspicious solid thyroid nodules needing cytological assessment and surgery. KEY POINTS: • Elastography is an additional tool for optimal characterisation of malignant thyroid nodules. • The use of semiquantitative elastographic evaluation increases the diagnostic performance, • The interobserver agreement of quantitative elastography can be considered to be good.


Assuntos
Calcinose/diagnóstico por imagem , Técnicas de Imagem por Elasticidade/métodos , Nódulo da Glândula Tireoide/diagnóstico por imagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Diagnóstico Diferencial , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Curva ROC , Reprodutibilidade dos Testes , Ultrassonografia Doppler em Cores/métodos , Adulto Jovem
4.
Med Ultrason ; 19(1): 32-38, 2017 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-28180194

RESUMO

AIMS: To assess the diagnostic value of elasticity contrast index (ECI) elastography, in comparison with conventional ultrasound for the differentiation of benign and malignant parotid lesions. MATERIAL AND METHODS: Sixty-three consecutive patients with parotid gland tumors, treated surgically at a single tertiary center were enrolled. Ultrasound evaluation consisted of B-mode, color-Doppler and quasistatic ultrasound elastography (USE), conducted with the ECI technique. For each lesion the echogenicity, margins, vascularization, and capsulation were considered to determine benign or malignant lesions. Histology was considered the gold standard. RESULTS: Using conventional parameters, the observer suggested malignant lesions in 20 cases and benign lesions in 43 cases (accuracy: 61.8%). ECI>3.5 alone was the most accurate parameter (accuracy: 90.5%), with sensitivity of 93.7% and specificity of 89.4%. However, when combined with the other US criteria, no statistically significant diagnostic accuracy improvement was achieved. CONCLUSIONS: Our results show that USE with ECI index measurement can help to discriminate preoperatively benign from malignant lesions, with the exception of pleomorphic adenoma which is stiff. We suggest that USE can be used as an additional tool to conventional US evaluation of salivary gland lesions.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Processamento de Imagem Assistida por Computador/métodos , Neoplasias Parotídeas/diagnóstico por imagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Glândula Parótida/diagnóstico por imagem , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Ultrassonografia/métodos , Adulto Jovem
5.
Eur J Radiol ; 84(9): 1658-65, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26198116

RESUMO

Endo vascular aortic repair [EVAR] is performed with low peri-operative morbidity and mortality rate and short hospital stay. However, EVAR needs a close and lifelong imagining surveillance for a timely detection of possible complications including endoleaks, graft migration, fractures, and enlargement of aneurysm sac size with eventual rupture. Contrast enhanced computed tomography [CTA] is actually considered the gold-standard in EVAR follow-up, but it is accompanied with radiation burden and renal injury due to the use of contrast media. In the last two decades several studies have shown the role of contrast enhanced ultrasound [CEUS] in post-EVAR surveillance, with very good diagnostic performance, absence of renal impairment, and no radiation, accompanied by low costs, in comparison with CTA. In numerous prospective studies and meta-analyses the detection and characterization of endoleaks with CEUS is comparable to that of CTA imaging. Nowadays, in the EVAR surveillance novel strategies which involve CEUS with a central role, are suggested by several authors and applied in many institutions. In this review article we will present a comprehensive overview and analyses of the literature on the CEUS state-of-art imagining of EVAR follow-up, with its technique, findings, diagnostic accuracy, and its role in the follow up program.


Assuntos
Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/terapia , Meios de Contraste , Procedimentos Endovasculares , Aumento da Imagem , Stents , Implante de Prótese Vascular/métodos , Endoleak/diagnóstico por imagem , Humanos , Ultrassonografia Doppler em Cores
6.
Int J Endocrinol ; 2015: 908575, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25954310

RESUMO

Thyroid nodules, with their high prevalence in the general population, represent a diagnostic challenge for clinicians. Ultrasound (US), although absolutely reliable in detecting thyroid nodules, is still not accurate enough to differentiate them into benign and malignant. A promising novel modality, US elastography, has been introduced in order to further increase US accuracy. The purpose of this review article is to assess the thyroid application of US strain elastography, also known as real-time elastography or quasistatic elastography. We provide a presentation of the technique, and of up-to-date literature, analyzing the most prominent results reported for thyroid nodules differentiation. The practical advantages and limitations of strain elastography are extensively discussed herein.

7.
J Ultrasound ; 17(1): 13-20, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24616747

RESUMO

PURPOSE: The aim of this study is to assess the diagnostic efficacy and interobserver agreement of acoustic radiation force impulse (ARFI) elasticity imaging in differentiating thyroid nodules. METHODS: In our study, 74 consecutive patients (52 females, 22 males; age range 27-77 years, mean: 41 years) with 82 thyroid nodules (60 benign nodules, and 22 malignant) were examined by two radiologists with different experience. Patients underwent either cytology using fine needle aspiration cytology or thyroid surgery. The diagnostic performance of the two operators at ARFI with sensitivity, specificity, positive predictive and negative predictive value, and ROC curves was estimated. Inter-reader variability between the two operators was defined using Cohen's k. RESULTS: According to receiver operating characteristics ROC curves (AUROC = 0.86 for observer 1; 0.81 for observer 2) sensitivity, specificity, PPV and NPV of reader 1 and 2 were respectively: 90, 75, 90.91 and 96.55 %; (cut-off value of shear wave: 2.455 m/s); 90, 72, 90 and 96.90 % (cut-off value shear wave: 2.365 m/s). Concordance between the two operators was good (k = 0.755). CONCLUSIONS: This work is a feasibility study evaluating ARFI imaging. Its results suggest that ARFI imaging is a reproducible method which can be utilized with good diagnostic performance in the thyroid for discriminating benign and malignant nodules using the cut-off value of 2.455 m/s. However, larger studies are needed to validate this method.

8.
Eur J Radiol ; 83(3): 420-8, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23763859

RESUMO

Thyroid pathology including thyroid nodules and diffuse thyroid diseases represents often a diagnosing challenge for clinicians. US, although highly accurate in identifying thyroid nodules and diffuse thyroid diseases, is still not sufficiently accurate to evaluate them. US-elastography has been introduced in order to further increase US accuracy in many fields and eventually for thyroid disease. The aim of the present paper it to provide an update of the literature on different available techniques and the results reported both for thyroid nodules differentiation and for diffuse thyroid disease evaluation. Advantages and limitations of elastography are also discussed.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Aumento da Imagem/métodos , Doenças da Glândula Tireoide/diagnóstico por imagem , Doenças da Glândula Tireoide/fisiopatologia , Glândula Tireoide/diagnóstico por imagem , Glândula Tireoide/fisiopatologia , Módulo de Elasticidade , Humanos
9.
World J Gastroenterol ; 20(29): 9998-10007, 2014 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-25110428

RESUMO

The development of ultrasound contrast agents with excellent tolerance and safety profiles has notably improved liver evaluation with ultrasound (US) for several applications, especially for the detection of metastases. In particular, contrast enhanced ultrasonography (CEUS) allows the display of the parenchymal microvasculature, enabling the study and visualization of the enhancement patterns of liver lesions in real time and in a continuous manner in all vascular phases, which is similar to contrast-enhanced computed tomography (CT) and contrast-enhanced magnetic resonance imaging. Clinical studies have reported that the use of a contrast agent enables the visualization of more metastases with significantly improved sensitivity and specificity compared to baseline-US. Furthermore, studies have shown that CEUS yields sensitivities comparable to CT. In this review, we describe the state of the art of CEUS for detecting colorectal liver metastases, the imaging features, the literature reports of metastases in CEUS as well as its technique, its clinical role and its potential applications. Additionally, the updated international consensus panel guidelines are reported in this review with the inherent limitations of this technique and best practice experiences.


Assuntos
Meios de Contraste , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/secundário , Imageamento por Ressonância Magnética , Tomografia Computadorizada por Raios X , Humanos , Neoplasias Hepáticas/terapia , Valor Preditivo dos Testes , Prognóstico , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa