Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
PLoS Comput Biol ; 20(4): e1011152, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38662736

RESUMO

Numerous physiological processes are cyclical, but sampling these processes densely enough to perform frequency decomposition and subsequent analyses can be challenging. Mathematical approaches for decomposition and reconstruction of sparsely and irregularly sampled signals are well established but have been under-utilized in physiological applications. We developed a basis pursuit denoising with polynomial detrending (BPWP) model that recovers oscillations and trends from sparse and irregularly sampled timeseries. We validated this model on a unique dataset of long-term inter-ictal epileptiform discharge (IED) rates from human hippocampus recorded with a novel investigational device with continuous local field potential sensing. IED rates have well established circadian and multiday cycles related to sleep, wakefulness, and seizure clusters. Given sparse and irregular samples of IED rates from multi-month intracranial EEG recordings from ambulatory humans, we used BPWP to compute narrowband spectral power and polynomial trend coefficients and identify IED rate cycles in three subjects. In select cases, we propose that random and irregular sampling may be leveraged for frequency decomposition of physiological signals. Trial Registration: NCT03946618.


Assuntos
Epilepsia , Humanos , Algoritmos , Biologia Computacional/métodos , Eletrocorticografia/métodos , Eletroencefalografia/métodos , Epilepsia/fisiopatologia , Epilepsia/diagnóstico , Hipocampo/fisiopatologia , Hipocampo/fisiologia , Modelos Neurológicos , Convulsões/fisiopatologia , Convulsões/diagnóstico , Processamento de Sinais Assistido por Computador , Feminino
2.
J Neurosci ; 43(24): 4434-4447, 2023 06 14.
Artigo em Inglês | MEDLINE | ID: mdl-37188514

RESUMO

The human ventral temporal cortex (VTC) is highly connected to integrate visual perceptual inputs with feedback from cognitive and emotional networks. In this study, we used electrical brain stimulation to understand how different inputs from multiple brain regions drive unique electrophysiological responses in the VTC. We recorded intracranial EEG data in 5 patients (3 female) implanted with intracranial electrodes for epilepsy surgery evaluation. Pairs of electrodes were stimulated with single-pulse electrical stimulation, and corticocortical evoked potential responses were measured at electrodes in the collateral sulcus and lateral occipitotemporal sulcus of the VTC. Using a novel unsupervised machine learning method, we uncovered 2-4 distinct response shapes, termed basis profile curves (BPCs), at each measurement electrode in the 11-500 ms after stimulation interval. Corticocortical evoked potentials of unique shape and high amplitude were elicited following stimulation of several regions and classified into a set of four consensus BPCs across subjects. One of the consensus BPCs was primarily elicited by stimulation of the hippocampus; another by stimulation of the amygdala; a third by stimulation of lateral cortical sites, such as the middle temporal gyrus; and the final one by stimulation of multiple distributed sites. Stimulation also produced sustained high-frequency power decreases and low-frequency power increases that spanned multiple BPC categories. Characterizing distinct shapes in stimulation responses provides a novel description of connectivity to the VTC and reveals significant differences in input from cortical and limbic structures.SIGNIFICANCE STATEMENT Disentangling the numerous input influences on highly connected areas in the brain is a critical step toward understanding how brain networks work together to coordinate human behavior. Single-pulse electrical stimulation is an effective tool to accomplish this goal because the shapes and amplitudes of signals recorded from electrodes are informative of the synaptic physiology of the stimulation-driven inputs. We focused on targets in the ventral temporal cortex, an area strongly implicated in visual object perception. By using a data-driven clustering algorithm, we identified anatomic regions with distinct input connectivity profiles to the ventral temporal cortex. Examining high-frequency power changes revealed possible modulation of excitability at the recording site induced by electrical stimulation of connected regions.


Assuntos
Córtex Cerebral , Lobo Temporal , Humanos , Feminino , Lobo Temporal/fisiologia , Potenciais Evocados/fisiologia , Hipocampo , Mapeamento Encefálico/métodos , Estimulação Elétrica/métodos
3.
J Neurosci ; 43(39): 6697-6711, 2023 09 27.
Artigo em Inglês | MEDLINE | ID: mdl-37620159

RESUMO

Stimulation-evoked signals are starting to be used as biomarkers to indicate the state and health of brain networks. The human limbic network, often targeted for brain stimulation therapy, is involved in emotion and memory processing. Previous anatomic, neurophysiological, and functional studies suggest distinct subsystems within the limbic network (Rolls, 2015). Studies using intracranial electrical stimulation, however, have emphasized the similarities of the evoked waveforms across the limbic network. We test whether these subsystems have distinct stimulation-driven signatures. In eight patients (four male, four female) with drug-resistant epilepsy, we stimulated the limbic system with single-pulse electrical stimulation. Reliable corticocortical evoked potentials (CCEPs) were measured between hippocampus and the posterior cingulate cortex (PCC) and between the amygdala and the anterior cingulate cortex (ACC). However, the CCEP waveform in the PCC after hippocampal stimulation showed a unique and reliable morphology, which we term the "limbic Hippocampus-Anterior nucleus of the thalamus-Posterior cingulate, HAP-wave." This limbic HAP-wave was visually distinct and separately decoded from the CCEP waveform in ACC after amygdala stimulation. Diffusion MRI data show that the measured end points in the PCC overlap with the end points of the parolfactory cingulum bundle rather than the parahippocampal cingulum, suggesting that the limbic HAP-wave may travel through fornix, mammillary bodies, and the anterior nucleus of the thalamus (ANT). This was further confirmed by stimulating the ANT, which evoked the same limbic HAP-wave but with an earlier latency. Limbic subsystems have unique stimulation-evoked signatures that may be used in the future to help network pathology diagnosis.SIGNIFICANCE STATEMENT The limbic system is often compromised in diverse clinical conditions, such as epilepsy or Alzheimer's disease, and characterizing its typical circuit responses may provide diagnostic insight. Stimulation-evoked waveforms have been used in the motor system to diagnose circuit pathology. We translate this framework to limbic subsystems using human intracranial stereo EEG (sEEG) recordings that measure deeper brain areas. Our sEEG recordings describe a stimulation-evoked waveform characteristic to the memory and spatial subsystem of the limbic network that we term the "limbic HAP-wave." The limbic HAP-wave follows anatomic white matter pathways from hippocampus to thalamus to the posterior cingulum and shows promise as a distinct biomarker of signaling in the human brain memory and spatial limbic network.


Assuntos
Núcleos Anteriores do Tálamo , Epilepsia , Humanos , Masculino , Feminino , Sistema Límbico/fisiologia , Eletroencefalografia , Potenciais Evocados/fisiologia , Estimulação Elétrica
4.
J Neurosci ; 43(39): 6653-6666, 2023 09 27.
Artigo em Inglês | MEDLINE | ID: mdl-37620157

RESUMO

The impedance is a fundamental electrical property of brain tissue, playing a crucial role in shaping the characteristics of local field potentials, the extent of ephaptic coupling, and the volume of tissue activated by externally applied electrical brain stimulation. We tracked brain impedance, sleep-wake behavioral state, and epileptiform activity in five people with epilepsy living in their natural environment using an investigational device. The study identified impedance oscillations that span hours to weeks in the amygdala, hippocampus, and anterior nucleus thalamus. The impedance in these limbic brain regions exhibit multiscale cycles with ultradian (∼1.5-1.7 h), circadian (∼21.6-26.4 h), and infradian (∼20-33 d) periods. The ultradian and circadian period cycles are driven by sleep-wake state transitions between wakefulness, nonrapid eye movement (NREM) sleep, and rapid eye movement (REM) sleep. Limbic brain tissue impedance reaches a minimum value in NREM sleep, intermediate values in REM sleep, and rises through the day during wakefulness, reaching a maximum in the early evening before sleep onset. Infradian (∼20-33 d) impedance cycles were not associated with a distinct behavioral correlate. Brain tissue impedance is known to strongly depend on the extracellular space (ECS) volume, and the findings reported here are consistent with sleep-wake-dependent ECS volume changes recently observed in the rodent cortex related to the brain glymphatic system. We hypothesize that human limbic brain ECS changes during sleep-wake state transitions underlie the observed multiscale impedance cycles. Impedance is a simple electrophysiological biomarker that could prove useful for tracking ECS dynamics in human health, disease, and therapy.SIGNIFICANCE STATEMENT The electrical impedance in limbic brain structures (amygdala, hippocampus, anterior nucleus thalamus) is shown to exhibit oscillations over multiple timescales. We observe that impedance oscillations with ultradian and circadian periodicities are associated with transitions between wakefulness, NREM, and REM sleep states. There are also impedance oscillations spanning multiple weeks that do not have a clear behavioral correlate and whose origin remains unclear. These multiscale impedance oscillations will have an impact on extracellular ionic currents that give rise to local field potentials, ephaptic coupling, and the tissue activated by electrical brain stimulation. The approach for measuring tissue impedance using perturbational electrical currents is an established engineering technique that may be useful for tracking ECS volume.


Assuntos
Sono REM , Sono , Humanos , Impedância Elétrica , Sono/fisiologia , Sono REM/fisiologia , Encéfalo/fisiologia , Vigília/fisiologia , Hipocampo
5.
PLoS Comput Biol ; 19(5): e1011105, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37228169

RESUMO

Single-pulse electrical stimulation in the nervous system, often called cortico-cortical evoked potential (CCEP) measurement, is an important technique to understand how brain regions interact with one another. Voltages are measured from implanted electrodes in one brain area while stimulating another with brief current impulses separated by several seconds. Historically, researchers have tried to understand the significance of evoked voltage polyphasic deflections by visual inspection, but no general-purpose tool has emerged to understand their shapes or describe them mathematically. We describe and illustrate a new technique to parameterize brain stimulation data, where voltage response traces are projected into one another using a semi-normalized dot product. The length of timepoints from stimulation included in the dot product is varied to obtain a temporal profile of structural significance, and the peak of the profile uniquely identifies the duration of the response. Using linear kernel PCA, a canonical response shape is obtained over this duration, and then single-trial traces are parameterized as a projection of this canonical shape with a residual term. Such parameterization allows for dissimilar trace shapes from different brain areas to be directly compared by quantifying cross-projection magnitudes, response duration, canonical shape projection amplitudes, signal-to-noise ratios, explained variance, and statistical significance. Artifactual trials are automatically identified by outliers in sub-distributions of cross-projection magnitude, and rejected. This technique, which we call "Canonical Response Parameterization" (CRP) dramatically simplifies the study of CCEP shapes, and may also be applied in a wide range of other settings involving event-triggered data.


Assuntos
Encéfalo , Potenciais Evocados , Potenciais Evocados/fisiologia , Mapeamento Encefálico/métodos , Eletrodos Implantados , Estimulação Elétrica/métodos
6.
Acta Neurochir (Wien) ; 166(1): 193, 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38662025

RESUMO

Vagal neuropathy causing vocal fold palsy is an uncommon complication of vagal nerve stimulator (VNS) placement. It may be associated with intraoperative nerve injury or with device stimulation. Here we present the first case of delayed, compressive vagal neuropathy associated with VNS coil placement which presented with progressive hoarseness and vocal cord paralysis. Coil removal and vagal neurolysis was performed to relieve the compression. Larger 3 mm VNS coils were placed for continuation of therapy. Coils with a larger inner diameter should be employed where possible to prevent this complication. The frequency of VNS-associated vagal nerve compression may warrant further investigation.


Assuntos
Estimulação do Nervo Vago , Paralisia das Pregas Vocais , Humanos , Masculino , Síndromes de Compressão Nervosa/etiologia , Síndromes de Compressão Nervosa/cirurgia , Nervo Vago , Doenças do Nervo Vago/etiologia , Doenças do Nervo Vago/cirurgia , Estimulação do Nervo Vago/efeitos adversos , Estimulação do Nervo Vago/instrumentação , Estimulação do Nervo Vago/métodos , Paralisia das Pregas Vocais/etiologia , Idoso
7.
Curr Opin Neurol ; 36(2): 69-76, 2023 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-36762660

RESUMO

PURPOSE OF REVIEW: Neurostimulation is a quickly growing treatment approach for epilepsy patients. We summarize recent approaches to provide a perspective on the future of neurostimulation. RECENT FINDINGS: Invasive stimulation for treatment of focal epilepsy includes vagus nerve stimulation, responsive neurostimulation of the cortex and deep brain stimulation of the anterior nucleus of the thalamus. A wide range of other targets have been considered, including centromedian, central lateral and pulvinar thalamic nuclei; medial septum, nucleus accumbens, subthalamic nucleus, cerebellum, fornicodorsocommissure and piriform cortex. Stimulation for generalized onset seizures and mixed epilepsies as well as increased efforts focusing on paediatric populations have emerged. Hardware with more permanently implanted lead options and sensing capabilities is emerging. A wider variety of programming approaches than typically used may improve patient outcomes. Finally, noninvasive brain stimulation with its favourable risk profile offers the potential to treat increasingly diverse epilepsy patients. SUMMARY: Neurostimulation for the treatment of epilepsy is surprisingly varied. Flexibility and reversibility of neurostimulation allows for rapid innovation. There remains a continued need for excitability biomarkers to guide treatment and innovation. Neurostimulation, a part of bioelectronic medicine, offers distinctive benefits as well as unique challenges.


Assuntos
Estimulação Encefálica Profunda , Epilepsia , Criança , Humanos , Epilepsia/terapia , Convulsões/terapia , Córtex Cerebral , Tálamo
8.
Epilepsia ; 64(2): e16-e22, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36385467

RESUMO

Deep brain stimulation and responsive neurostimulation (RNS) use high-frequency stimulation (HFS) per the pivotal trials and manufacturer-recommended therapy protocols. However, not all patients respond to HFS. In this retrospective case series, 10 patients implanted with the RNS System were programmed with low-frequency stimulation (LFS) to treat their seizures; nine of these patients were previously treated with HFS (100 Hz or greater). LFS was defined as frequency < 10 Hz. Burst duration was increased to at least 1000 ms. With HFS, patients had a median seizure reduction (MSR) of 13% (interquartile range [IQR] = -67 to 54) after a median of 19 months (IQR = 8-49). In contrast, LFS was associated with a 67% MSR (IQR = 13-95) when compared to HFS and 76% MSR (IQR = 43-91) when compared to baseline prior to implantation. Charge delivered per hour and pulses per day were not significantly different between HFS and LFS, although time stimulated per day was longer for LFS (228 min) than for HFS (7 min). There were no LFS-specific adverse effects reported by any of the patients. LFS could represent an alternative, effective method for delivering stimulation in focal drug-resistant epilepsy patients treated with the RNS System.


Assuntos
Estimulação Encefálica Profunda , Epilepsia Resistente a Medicamentos , Humanos , Estimulação Encefálica Profunda/métodos , Estudos Retrospectivos , Convulsões/terapia , Epilepsia Resistente a Medicamentos/terapia , Eletrodos Implantados
9.
Epilepsia ; 64(6): 1627-1639, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37060170

RESUMO

OBJECTIVE: The factors that influence seizure timing are poorly understood, and seizure unpredictability remains a major cause of disability. Work in chronobiology has shown that cyclical physiological phenomena are ubiquitous, with daily and multiday cycles evident in immune, endocrine, metabolic, neurological, and cardiovascular function. Additionally, work with chronic brain recordings has identified that seizure risk is linked to daily and multiday cycles in brain activity. Here, we provide the first characterization of the relationships between the cyclical modulation of a diverse set of physiological signals, brain activity, and seizure timing. METHODS: In this cohort study, 14 subjects underwent chronic ambulatory monitoring with a multimodal wrist-worn sensor (recording heart rate, accelerometry, electrodermal activity, and temperature) and an implanted responsive neurostimulation system (recording interictal epileptiform abnormalities and electrographic seizures). Wavelet and filter-Hilbert spectral analyses characterized circadian and multiday cycles in brain and wearable recordings. Circular statistics assessed electrographic seizure timing and cycles in physiology. RESULTS: Ten subjects met inclusion criteria. The mean recording duration was 232 days. Seven subjects had reliable electroencephalographic seizure detections (mean = 76 seizures). Multiday cycles were present in all wearable device signals across all subjects. Seizure timing was phase locked to multiday cycles in five (temperature), four (heart rate, phasic electrodermal activity), and three (accelerometry, heart rate variability, tonic electrodermal activity) subjects. Notably, after regression of behavioral covariates from heart rate, six of seven subjects had seizure phase locking to the residual heart rate signal. SIGNIFICANCE: Seizure timing is associated with daily and multiday cycles in multiple physiological processes. Chronic multimodal wearable device recordings can situate rare paroxysmal events, like seizures, within a broader chronobiology context of the individual. Wearable devices may advance the understanding of factors that influence seizure risk and enable personalized time-varying approaches to epilepsy care.


Assuntos
Epilepsia , Convulsões , Humanos , Estudos de Coortes , Convulsões/diagnóstico , Eletroencefalografia , Monitorização Ambulatorial
10.
Stereotact Funct Neurosurg ; 101(4): 254-264, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37454656

RESUMO

BACKGROUND: Implantable pulse generators (IPGs) store energy and deliver electrical impulses for deep brain stimulation (DBS) to treat neurological and psychiatric disorders. IPGs have evolved over time to meet the demands of expanding clinical indications and more nuanced therapeutic approaches. OBJECTIVES: The aim of this study was to examine the workflow of the first 4-lead IPG for DBS in patients with complex disease. METHOD: The engineering capabilities, clinical use cases, and surgical technique are described in a cohort of 12 patients with epilepsy, essential tremor, Parkinson's disease, mixed tremor, and Tourette's syndrome with comorbid obsessive-compulsive disorder between July 2021 and July 2022. RESULTS: This system is a rechargeable 32-channel, 4-port system with independent current control that can be connected to 8 contact linear or directionally segmented leads. The system is ideal for patients with mixed disease or those with multiple severe symptoms amenable to >2 lead implantations. A multidisciplinary team including neurologists, radiologists, and neurosurgeons is necessary to safely plan the procedure. There were no serious intraoperative or postoperative adverse events. One patient required revision surgery for bowstringing. CONCLUSIONS: This new 4-lead IPG represents an important new tool for DBS surgery with the ability to expand lead implantation paradigms for patients with complex disease.


Assuntos
Estimulação Encefálica Profunda , Doença de Parkinson , Humanos , Estimulação Encefálica Profunda/métodos , Eletrodos Implantados , Fontes de Energia Elétrica , Tremor/terapia , Doença de Parkinson/cirurgia
11.
Epilepsia ; 2022 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-35604546

RESUMO

To date, the unpredictability of seizures remains a source of suffering for people with epilepsy, motivating decades of research into methods to forecast seizures. Originally, only few scientists and neurologists ventured into this niche endeavor, which, given the difficulty of the task, soon turned into a long and winding road. Over the past decade, however, our narrow field has seen a major acceleration, with trials of chronic electroencephalographic devices and the subsequent discovery of cyclical patterns in the occurrence of seizures. Now, a burgeoning science of seizure timing is emerging, which in turn informs best forecasting strategies for upcoming clinical trials. Although the finish line might be in view, many challenges remain to make seizure forecasting a reality. This review covers the most recent scientific, technical, and medical developments, discusses methodology in detail, and sets a number of goals for future studies.

12.
Epilepsy Behav ; 137(Pt A): 108951, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36327647

RESUMO

BACKGROUND: Drug-resistant epilepsy (DRE) patients not amenable to epilepsy surgery can benefit from neurostimulation. Few data compare different neuromodulation strategies. OBJECTIVE: Compare five invasive neuromodulation strategies for the treatment of DRE: anterior thalamic nuclei deep brain stimulation (ANT-DBS), centromedian thalamic nuclei DBS (CM-DBS), responsive neurostimulation (RNS), chronic subthreshold stimulation (CSS), and vagus nerve stimulation (VNS). METHODS: Single center retrospective review and phone survey for patients implanted with invasive neuromodulation for 2004-2021. RESULTS: N = 159 (ANT-DBS = 38, CM-DBS = 19, RNS = 30, CSS = 32, VNS = 40). Total median seizure reduction (MSR) was 61 % for the entire cohort (IQR 5-90) and in descending order: CSS (85 %), CM-DBS (63 %), ANT-DBS (52 %), RNS (50 %), and VNS (50 %); p = 0.07. The responder rate was 60 % after a median follow-up time of 26 months. Seizure severity, life satisfaction, and quality of sleep were improved. Cortical stimulation (RNS and CSS) was associated with improved seizure reduction compared to subcortical stimulation (ANT-DBS, CM-DBS, and VNS) (67 % vs. 52 %). Effectiveness was similar for focal epilepsy vs. generalized epilepsy, closed-loop vs. open-loop stimulation, pediatric vs. adult cases, and high frequency (>100 Hz) vs. low frequency (<100 Hz) stimulation settings. Delivered charge per hour varied widely across approaches but was not correlated with improved seizure reduction. CONCLUSIONS: Multiple invasive neuromodulation approaches are available to treat DRE, but little evidence compares the approaches. This study used a uniform approach for single-center results and represents an effort to compare neuromodulation approaches.


Assuntos
Núcleos Anteriores do Tálamo , Estimulação Encefálica Profunda , Epilepsia Resistente a Medicamentos , Epilepsia , Adulto , Humanos , Criança , Estimulação Encefálica Profunda/métodos , Epilepsia/terapia , Epilepsia Resistente a Medicamentos/terapia , Convulsões , Resultado do Tratamento
13.
Epilepsia ; 62(10): e158-e164, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34418083

RESUMO

There is a paucity of data to guide anterior nucleus of the thalamus (ANT) deep brain stimulation (DBS) with brain sensing. The clinical Medtronic Percept DBS device provides constrained brain sensing power within a frequency band (power-in-band [PIB]), recorded in 10-min averaged increments. Here, four patients with temporal lobe epilepsy were implanted with an investigational device providing full bandwidth chronic intracranial electroencephalogram (cEEG) from bilateral ANT and hippocampus (Hc). ANT PIB-based seizure detection was assessed. Detection parameters were cEEG PIB center frequency, bandwidth, and epoch duration. Performance was evaluated against epileptologist-confirmed Hc seizures, and assessed by area under the precision-recall curve (PR-AUC). Data included 99 days of cEEG, and 20, 278, 3, and 18 Hc seizures for Subjects 1-4. The best detector had 7-Hz center frequency, 5-Hz band width, and 10-s epoch duration (group PR-AUC = .90), with 75% sensitivity and .38 false alarms per day for Subject 1, and 100% and .0 for Subjects 3 and 4. Hc seizures in Subject 2 did not propagate to ANT. The relative change of ANT PIB was maximal ipsilateral to seizure onset for all detected seizures. Chronic ANT and Hc recordings provide direct guidance for ANT DBS with brain sensing.


Assuntos
Núcleos Anteriores do Tálamo , Estimulação Encefálica Profunda , Epilepsia , Núcleos Anteriores do Tálamo/fisiologia , Epilepsia/terapia , Hipocampo/diagnóstico por imagem , Humanos , Convulsões/diagnóstico , Tálamo
14.
Epilepsia ; 61 Suppl 1: S25-S35, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32497269

RESUMO

Noninvasive wearable devices have great potential to aid the management of epilepsy, but these devices must have robust signal quality, and patients must be willing to wear them for long periods of time. Automated machine learning classification of wearable biosensor signals requires quantitative measures of signal quality to automatically reject poor-quality or corrupt data segments. In this study, commercially available wearable sensors were placed on patients with epilepsy undergoing in-hospital or in-home electroencephalographic (EEG) monitoring, and healthy volunteers. Empatica E4 and Biovotion Everion were used to record accelerometry (ACC), photoplethysmography (PPG), and electrodermal activity (EDA). Byteflies Sensor Dots were used to record ACC and PPG, the Activinsights GENEActiv watch to record ACC, and Epitel Epilog to record EEG data. PPG and EDA signals were recorded for multiple days, then epochs of high-quality, marginal-quality, or poor-quality data were visually identified by reviewers, and reviewer annotations were compared to automated signal quality measures. For ACC, the ratio of spectral power from 0.8 to 5 Hz to broadband power was used to separate good-quality signals from noise. For EDA, the rate of amplitude change and prevalence of sharp peaks significantly differentiated between good-quality data and noise. Spectral entropy was used to assess PPG and showed significant differences between good-, marginal-, and poor-quality signals. EEG data were evaluated using methods to identify a spectral noise cutoff frequency. Patients were asked to rate the usability and comfort of each device in several categories. Patients showed a significant preference for the wrist-worn devices, and the Empatica E4 device was preferred most often. Current wearable devices can provide high-quality data and are acceptable for routine use, but continued development is needed to improve data quality, consistency, and management, as well as acceptability to patients.


Assuntos
Acelerometria/instrumentação , Epilepsia , Resposta Galvânica da Pele/fisiologia , Monitorização Ambulatorial/instrumentação , Fotopletismografia/instrumentação , Dispositivos Eletrônicos Vestíveis , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Preferência do Paciente , Processamento de Sinais Assistido por Computador , Adulto Jovem
15.
Neurosurg Focus Video ; 11(1): V10, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38957423

RESUMO

Neurostimulation is an increasingly common treatment option for medically intractable epilepsy. SANTE (Stimulation of the Anterior Nucleus of the Thalamus for Epilepsy) and Responsive Neurostimulation (RNS) System are landmark neurostimulation trials that utilized either duty cycle or a responsive stimulation paradigm. A seizure-free outcome is rarely observed with responsive and duty cycle neurostimulation devices. Chronic subthreshold cortical stimulation (CSCS) is a promising treatment for adult drug-resistant epilepsy involving eloquent cortex and has demonstrated safety and efficacy. Herein, the authors describe the surgical technique as well as details of stimulation programming involved in CSCS placement to facilitate the adoption of this promising treatment. The video can be found here: https://stream.cadmore.media/r10.3171/2024.4.FOCVID2422.

16.
J Neurosci Methods ; 407: 110153, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38710234

RESUMO

Human brain connectivity can be mapped by single pulse electrical stimulation during intracranial EEG measurements. The raw cortico-cortical evoked potentials (CCEP) are often contaminated by noise. Common average referencing (CAR) removes common noise and preserves response shapes but can introduce bias from responsive channels. We address this issue with an adjusted, adaptive CAR algorithm termed "CAR by Least Anticorrelation (CARLA)". CARLA was tested on simulated CCEP data and real CCEP data collected from four human participants. In CARLA, the channels are ordered by increasing mean cross-trial covariance, and iteratively added to the common average until anticorrelation between any single channel and all re-referenced channels reaches a minimum, as a measure of shared noise. We simulated CCEP data with true responses in 0-45 of 50 total channels. We quantified CARLA's error and found that it erroneously included 0 (median) truly responsive channels in the common average with ≤42 responsive channels, and erroneously excluded ≤2.5 (median) unresponsive channels at all responsiveness levels. On real CCEP data, signal quality was quantified with the mean R2 between all pairs of channels, which represents inter-channel dependency and is low for well-referenced data. CARLA re-referencing produced significantly lower mean R2 than standard CAR, CAR using a fixed bottom quartile of channels by covariance, and no re-referencing. CARLA minimizes bias in re-referenced CCEP data by adaptively selecting the optimal subset of non-responsive channels. It showed high specificity and sensitivity on simulated CCEP data and lowered inter-channel dependency compared to CAR on real CCEP data.


Assuntos
Algoritmos , Córtex Cerebral , Potenciais Evocados , Processamento de Sinais Assistido por Computador , Humanos , Potenciais Evocados/fisiologia , Córtex Cerebral/fisiologia , Masculino , Eletrocorticografia/métodos , Eletroencefalografia/métodos , Adulto , Estimulação Elétrica , Simulação por Computador , Feminino
17.
medRxiv ; 2024 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-38496621

RESUMO

Deep brain stimulation (DBS) is a viable treatment for a variety of neurological conditions, however, the mechanisms through which DBS modulates large-scale brain networks are unresolved. Clinical effects of DBS are observed over multiple timescales. In some conditions, such as Parkinson's disease and essential tremor, clinical improvement is observed within seconds. In many other conditions, such as epilepsy, central pain, dystonia, neuropsychiatric conditions or Tourette syndrome, the DBS related effects are believed to require neuroplasticity or reorganization and often take hours to months to observe. To optimize DBS parameters, it is therefore essential to develop electrophysiological biomarkers that characterize whether DBS settings are successfully engaging and modulating the network involved in the disease of interest. In this study, 10 individuals with drug resistant epilepsy undergoing intracranial stereotactic EEG including a thalamus electrode underwent a trial of repetitive thalamic stimulation. We evaluated thalamocortical effective connectivity using single pulse electrical stimulation, both at baseline and following a 145 Hz stimulation treatment trial. We found that when high frequency stimulation was delivered for >1.5 hours, the evoked potentials measured from remote regions were significantly reduced in amplitude and the degree of modulation was proportional to the strength of baseline connectivity. When stimulation was delivered for shorter time periods, results were more variable. These findings suggest that changes in effective connectivity in the network targeted with DBS accumulate over hours of DBS. Stimulation evoked potentials provide an electrophysiological biomarker that allows for efficient data-driven characterization of neuromodulation effects, which could enable new objective approaches for individualized DBS optimization.

18.
bioRxiv ; 2024 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-38260687

RESUMO

Human brain connectivity can be measured in different ways. Intracranial EEG (iEEG) measurements during single pulse electrical stimulation provide a unique way to assess the spread of electrical information with millisecond precision. To provide a robust workflow to process these cortico-cortical evoked potential (CCEP) data and detect early evoked responses in a fully automated and reproducible fashion, we developed Early Response (ER)-detect. ER-detect is an open-source Python package and Docker application to preprocess BIDS structured iEEG data and detect early evoked CCEP responses. ER-detect can use three response detection methods, which were validated against 14-manually annotated CCEP datasets from two different sites by four independent raters. Results showed that ER-detect's automated detection performed on par with the inter-rater reliability (Cohen's Kappa of ~0.6). Moreover, ER-detect was optimized for processing large CCEP datasets, to be used in conjunction with other connectomic investigations. ER-detect provides a highly efficient standardized workflow such that iEEG-BIDS data can be processed in a consistent manner and enhance the reproducibility of CCEP based connectivity results.

19.
medRxiv ; 2024 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-38405801

RESUMO

High frequency anterior nucleus of the thalamus deep brain stimulation (ANT DBS) is an established therapy for treatment resistant focal epilepsies. Although high frequency-ANT DBS is well tolerated, patients are rarely seizure free and the efficacy of other DBS parameters and their impact on comorbidities of epilepsy such as depression and memory dysfunction remain unclear. The purpose of this study was to assess the impact of low vs high frequency ANT DBS on verbal memory and self-reported anxiety and depression symptoms. Five patients with treatment resistant temporal lobe epilepsy were implanted with an investigational brain stimulation and sensing device capable of ANT DBS and ambulatory intracranial electroencephalographic (iEEG) monitoring, enabling long-term detection of electrographic seizures. While patients received therapeutic high frequency (100 and 145 Hz continuous and cycling) and low frequency (2 and 7 Hz continuous) stimulation, they completed weekly free recall verbal memory tasks and thrice weekly self-reports of anxiety and depression symptom severity. Mixed effects models were then used to evaluate associations between memory scores, anxiety and depression self-reports, seizure counts, and stimulation frequency. Memory score was significantly associated with stimulation frequency, with higher free recall verbal memory scores during low frequency ANT DBS. Self-reported anxiety and depression symptom severity was not significantly associated with stimulation frequency. These findings suggest the choice of ANT DBS stimulation parameter may impact patients' cognitive function, independently of its impact on seizure rates.

20.
medRxiv ; 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38370724

RESUMO

Temporal lobe epilepsy is a common neurological disease characterized by recurrent seizures. These seizures often originate from limbic networks and people also experience chronic comorbidities related to memory, mood, and sleep (MMS). Deep brain stimulation targeting the anterior nucleus of the thalamus (ANT-DBS) is a proven therapy, but the optimal stimulation parameters remain unclear. We developed a neurotechnology platform for tracking seizures and MMS to enable data streaming between an investigational brain sensing-stimulation implant, mobile devices, and a cloud environment. Artificial Intelligence algorithms provided accurate catalogs of seizures, interictal epileptiform spikes, and wake-sleep brain states. Remotely administered memory and mood assessments were used to densely sample cognitive and behavioral response during ANT-DBS. We evaluated the efficacy of low-frequency versus high-frequency ANT-DBS. They both reduced seizures, but low-frequency ANT-DBS showed greater reductions and better sleep and memory. These results highlight the potential of synchronized brain sensing and behavioral tracking for optimizing neuromodulation therapy.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa