RESUMO
Bacterial biofilms are often found in chronically infected wounds. Biofilms protect bacteria from antibiotics and impair wound healing. Surgical debridement is often needed to remove the biofilm from an infected wound. Laser-generated shockwave (LGS) treatment is a novel tissue-sparing treatment for biofilm disruption. Previous studies have demonstrated that LGS is effective in disrupting biofilms in vitro. In this study, we aim to determine the safety threshold of the LGS technology in an in vivo rodent model. To understand the in vivo effects of LGS on healthy cutaneous tissue, the de-haired dorsal skin of Sprague-Dawley rats were treated with LGS at three different peak pressures (118, 296, 227 MPa). These pressures were generated using a 1064 nm Nd/YAG laser (pulse duration 5 ns and laser fluence of 777.9 mJ) with laser spot size diameters of 2.2, 3.0, and 4.2 mm, respectively. Following treatment, the animals were observed for 72 h, and a small subset was euthanized at 1-h, 24-h, and 72-h post-treatment and assessed for tissue injury or inflammation under histology. Each treatment group consisted of 9 rats (n = 3/time point for 1-h, 24-h, 72-h post-treatment). An additional 4 control (untreated) rats were included in the analysis, for a total of 31 animals. Gross injuries occurred in 21 (77%) animals and consisted of minor erythema, with prevalence positively correlated with peak pressure (p < 0.05). Of injuries under gross observation, 94% resolved within 24 h. Under histological analysis, the injuries and tissue inflammation were found to be localized to the epidermis and superficial dermis. LGS appears to be well tolerated by cutaneous tissue for the laser energy settings shown to be effective against bacterial biofilm in vitro. All injuries incurred, at even the highest peak pressures, were clinically mild and resolved within 1 day. This lends further support to the overall safety of LGS and serves to translate LGS towards in vivo efficacy studies.
Assuntos
Biofilmes , Lasers de Estado Sólido , Roedores , Infecção da Ferida Cirúrgica , Animais , Bactérias , Ratos , Ratos Sprague-Dawley , Infecção da Ferida Cirúrgica/prevenção & controleRESUMO
BACKGROUND: The loss of tactile feedback in minimally invasive robotic surgery remains a major challenge to the expanding field. With visual cue compensation alone, tissue characterization via palpation proves to be immensely difficult. This work evaluates a bimodal vibrotactile system as a means of conveying applied forces to simulate haptic feedback in two sets of studies simulating an artificial palpation task using the da Vinci surgical robot. METHODS: Subjects in the first study were tasked with localizing an embedded vessel in a soft tissue phantom using a single-sensor unit. In the second study, subjects localized tumor-like structures using a three-sensor array. In both sets of studies, subjects completed the task under three trial conditions: no feedback, normal force tactile feedback, and hybrid vibrotactile feedback. Recordings of correct localization, incorrect localization, and time-to-completion were used to evaluate performance outcomes. RESULTS: With the addition of vibrotactile and pneumatic feedback, significant improvements in the percentage of correct localization attempts were detected (p = 0.0001 and p = 0.0459, respectively) during the first experiment with phantom vessels. Similarly, significant improvements in correct localization were found with the addition of vibrotactile (p = 2.57E-5) and pneumatic significance (p = 8.54E-5) were observed in the second experiment involving tumor phantoms. CONCLUSIONS: This work demonstrates not only the superior benefits of a multi-modal feedback over traditional single-modality feedback, but also the effectiveness of vibration in providing haptic feedback to artificial palpation systems.
Assuntos
Retroalimentação Sensorial , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Palpação/métodos , Procedimentos Cirúrgicos Robóticos/métodos , Vasos Sanguíneos , Desenho de Equipamento , Humanos , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Modelos Anatômicos , Neoplasias , Palpação/instrumentação , Procedimentos Cirúrgicos Robóticos/instrumentação , Tato , VibraçãoRESUMO
Background and Objectives Laser generated shockwave (LGS) is a novel modality for minimally invasive disruption of bacterial biofilms. The objectives of this study are to determine the mechanisms behind LGS treatment and non-biofilm effects on bacterial disruption, including (1) comparing bacterial load with and without LGS in its planktonic form and (2) estimating bacterial cell permeability following LGS. Study Design/Materials and Methods For the first study, planktonic S. epidermidis were treated with gentamicin (0, 8, 16, 32, 64 µg/ml) with and without LGS (1064 nm Nd:YAG laser, 110.14 mJ/mm2 , pulse duration 9 ns, spot size 3 mm, n = 8/group), and absorbances at 600 nm compared. For the second study, four samples of planktonic S. epidermidis were treated with LGS (same settings). Propidium iodide (PI) uptake via flow cytometry as a measure of cell permeability was measured at 0, 10, and 20 minutes following LGS. RESULTS: In comparing corresponding gentamicin concentrations within both LGS-treated samples and controls at 0 hours, there were no differences in absorbance (P = 0.923 and P = 0.814, respectively). Flow cytometry found modest PI uptake (10.4 ± 2.5%) immediately following LGS treatment, with time-dependent increase and persistence of the signal at 20 minutes (R2 = 0.449, P = 0.048). CONCLUSION: Taken together, LGS does not appear to have direct bacteriocidal properties, but rather by allowing for biofilm disruption and bacterial cell membrane permeabilization, both of which likely increase topical antibiotic delivery to pathogenic organisms. Insight into the mechanisms of LGS will allow for improved clinical applications and facilitate safe and effective translation of this technology. Lasers Surg. Med. © 2018 Wiley Periodicals, Inc.
Assuntos
Carga Bacteriana/efeitos da radiação , Biofilmes/efeitos da radiação , Membrana Celular/efeitos da radiação , Lasers de Estado Sólido , Staphylococcus epidermidis/efeitos da radiação , Antibacterianos/farmacologia , Carga Bacteriana/efeitos dos fármacos , Biofilmes/efeitos dos fármacos , Membrana Celular/efeitos dos fármacos , Citometria de Fluxo , Gentamicinas/farmacologia , Permeabilidade/efeitos dos fármacos , Permeabilidade/efeitos da radiação , Plâncton/efeitos dos fármacos , Plâncton/efeitos da radiação , Staphylococcus epidermidis/efeitos dos fármacosRESUMO
Oral and head and neck squamous cell carcinoma (OSCC) is the sixth most common cancer worldwide. The primary management of OSCC relies on complete surgical resection of the tumor. Margin-free resection, however, is difficult given the devastating effects of aggressive surgery. Currently, surgeons determine where cuts are made by palpating edges of the tumor. Accuracy varies based on the surgeon's experience, the location and type of tumor, and the risk of damage to adjacent structures limiting resection margins. To fulfill this surgical need, we contrast tissue regions by identifying disparities in viscoelasticity by mixing two ultrasonic beams to produce a beat frequency, a technique termed vibroacoustography (VA). In our system, an extended focal length of the acoustic stress field yields surgeons' high resolution to detect focal lesions in deep tissue. VA offers 3D imaging by focusing its imaging plane at multiple axial cross-sections within tissue. Our efforts culminate in production of a mobile VA system generating image contrast between normal and abnormal tissue in minutes. We model the spatial direction of the generated acoustic field and generate images from tissue-mimicking phantoms and ex vivo specimens with squamous cell carcinoma of the tongue to qualitatively demonstrate the functionality of our system. These preliminary results warrant additional validation as we continue clinical trials of ex vivo tissue. This tool may prove especially useful for finding tumors that are deep within tissue and often missed by surgeons. The complete primary resection of tumors may reduce recurrence and ultimately improve patient outcomes.
Assuntos
Carcinoma de Células Escamosas/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Cinetocardiografia/métodos , Humanos , Imageamento TridimensionalRESUMO
BACKGROUND: Robotic surgical platforms have seen increased use among minimally invasive gastrointestinal surgeons (von Fraunhofer et al. in J Biomed Mater Res 19(5):595-600, 1985. doi: 10.1002/jbm.820190511 ). However, these systems still suffer from lack of haptic feedback, which results in exertion of excessive force, often leading to suture failures (Barbash et al. in Ann Surg 259(1):1-6, 2014. doi: 10.1097/SLA.0b013e3182a5c8b8 ). This work catalogs tensile strength and failure load among commonly used sutures in an effort to prevent robotic surgical consoles from exceeding identified thresholds. Trials were thus conducted on common sutures varying in material type, gauge size, rate of pulling force, and method of applied force. METHODS: Polydioxanone, Silk, Vicryl, and Prolene, gauges 5-0 to 1-0, were pulled till failure using a commercial mechanical testing system. 2-0 and 3-0 sutures were further tested for the effect of pull rate on failure load at rates of 50, 200, and 400 mm/min. 3-0 sutures were also pulled till failure using a da Vinci robotic surgical system in unlooped, looped, and at the needle body arrangements. RESULTS: Generally, Vicryl and PDS sutures had the highest mechanical strength (47-179 kN/cm2), while Silk had the lowest (40-106 kN/cm2). Larger diameter sutures withstand higher total force, but finer gauges consistently show higher force per unit area. The difference between material types becomes increasingly significant as the diameters decrease. Comparisons of identical suture materials and gauges show 27-50% improvement in the tensile strength over data obtained in 1985 (Ballantyne in Surg Endosc Other Interv Tech 16(10):1389-1402, 2002. doi: 10.1007/s00464-001-8283-7 ). No significant differences were observed when sutures were pulled at different rates. Reduction in suture strength appeared to be strongly affected by the technique used to manipulate the suture. CONCLUSIONS: Availability of suture tensile strength and failure load data will help define software safety protocols for alerting a surgeon prior to suture failure during robotic surgery. Awareness of suture strength weakening with direct instrument manipulation may lead to the development of better techniques to further reduce intraoperative suture breakage.
Assuntos
Procedimentos Cirúrgicos Robóticos/normas , Técnicas de Sutura/normas , Suturas/normas , Resistência à Tração , Análise de Falha de Equipamento , Teste de Materiais/métodos , Polidioxanona , Poliglactina 910 , Polipropilenos , Técnicas de Sutura/instrumentaçãoRESUMO
BACKGROUND: The principal objective of the experiment was to analyze the effects of the clutch operation of robotic surgical systems on the performance of the operator. The relative coordinate system introduced by the clutch operation can introduce a visual-perceptual mismatch which can potentially have negative impact on a surgeon's performance. We also assess the impact of the introduction of additional tactile sensory information on reducing the impact of visual-perceptual mismatch on the performance of the operator. METHODS: We asked 45 novice subjects to complete peg transfers using the da Vinci IS 1200 system with grasper-mounted, normal force sensors. The task involves picking up a peg with one of the robotic arms, passing it to the other arm, and then placing it on the opposite side of the view. Subjects were divided into three groups: aligned group (no mismatch), the misaligned group (10 cm z axis mismatch), and the haptics-misaligned group (haptic feedback and z axis mismatch). Each subject performed the task five times, during which the grip force, time of completion, and number of faults were recorded. RESULTS: Compared to the subjects that performed the tasks using a properly aligned controller/arm configuration, subjects with a single-axis misalignment showed significantly more peg drops (p = 0.011) and longer time to completion (p < 0.001). Additionally, it was observed that addition of tactile feedback helps reduce the negative effects of visual-perceptual mismatch in some cases. Grip force data recorded from grasper-mounted sensors showed no difference between the different groups. CONCLUSIONS: The visual-perceptual mismatch created by the misalignment of the robotic controls relative to the robotic arms has a negative impact on the operator of a robotic surgical system. Introduction of other sensory information and haptic feedback systems can help in potentially reducing this effect.
Assuntos
Retroalimentação Sensorial , Cirurgia Geral/métodos , Procedimentos Cirúrgicos Robóticos , Percepção Visual , Adulto , Feminino , Humanos , Masculino , Análise e Desempenho de TarefasRESUMO
BACKGROUND AND OBJECTIVES: Bacterial biofilm formation within chronic wound beds, which provides an effective barrier against antibiotics, is a known cause of recalcitrant infections and a significant healthcare burden, often requiring repeated surgical debridements. Laser-generated shockwaves (LGS) is a novel, minimally invasive, and nonthermal modality for biofilm mechanical debridement which utilizes compressive stress waves, generated by photonic absorption in thin titanium films to mechanically disrupt the biofilm. Prior studies have demonstrated LGS monotherapy to be selectively efficacious for biofilm disruption and safe for host tissues. In this study, we sought to determine if LGS can enhance the antimicrobial activity and biofilm disruption capability of topical antibiotic therapy. STUDY DESIGN/MATERIALS AND METHODS: Staphylococcus epidermidis biofilms grown in vitro on glass were treated with topical gentamicin (31, 62, and 124 µg/ml) with and without LGS (n = 3-11/treatment group). Mechanical shockwaves were generated with a 1,064 nm Nd:YAG laser (laser fluence 110.14 mJ/mm2 , pulse duration 5 ns, spot size 3 mm). Following a 24-hour incubation period, bacterial viability was assessed by determining the number of colony-forming units (CFU) via the Miles and Misra method. Residual biofilm bioburden was analyzed using the crystal violet biofilm assay. RESULTS: With gentamicin monotherapy, CFU density (CFU/mm2 ) at 31, 62, and 124 µg/ml were (282 ± 84) × 104 , (185 ± 34) × 104 , and (113 ± 9) × 104 , respectively. With LGS and gentamicin therapy, CFU density decreased to (170 ± 44) × 104 , (89 ± 24) × 104 , and (43 ± 3) × 104 , respectively (P = 0.1704, 0.0302, and 0.0004 when compared with gentamicin alone). Biofilm burden as measured by the assay in the gentamicin 31, 62, and 124 µg/ml groups was reduced by 80%, 95%, and 98% when LGS was added (P = 0.0102, >0.0001, and 0.0001 for all groups when compared with gentamicin alone). Furthermore, samples treated with LGS saw an increase in susceptibility to gentamicin, in terms of reduced biofilm bioburden and CFU densities. CONCLUSION: LGS enhances the efficacy of topical antibiotics in an in vitro model. This has significant implications for clinical applications in the management of chronic soft tissue infections and recalcitrant chronic rhinosinusitis. Lasers Surg. Med. 49:539-547, 2017. © 2017 Wiley Periodicals, Inc.
Assuntos
Antibacterianos/uso terapêutico , Biofilmes/efeitos da radiação , Gentamicinas/uso terapêutico , Ondas de Choque de Alta Energia , Lasers de Estado Sólido/uso terapêutico , Staphylococcus epidermidis/efeitos da radiação , Carga Bacteriana/efeitos dos fármacos , Carga Bacteriana/efeitos da radiação , Biofilmes/crescimento & desenvolvimento , Staphylococcus epidermidis/efeitos dos fármacos , Staphylococcus epidermidis/fisiologiaRESUMO
INTRODUCTION: The aims of this study were to evaluate (1) grasping forces with the application of a tactile feedback system in vivo and (2) the incidence of tissue damage incurred during robotic tissue manipulation. Robotic-assisted minimally invasive surgery has been shown to be beneficial in a variety of surgical specialties, particularly radical prostatectomy. This innovative surgical tool offers advantages over traditional laparoscopic techniques, such as improved wrist-like maneuverability, stereoscopic video displays, and scaling of surgical gestures to increase precision. A widely cited disadvantage associated with robotic systems is the absence of tactile feedback. METHODS AND PROCEDURE: Nineteen subjects were categorized into two groups: 5 experts (six or more robotic cases) and 14 novices (five cases or less). The subjects used the da Vinci with integrated tactile feedback to run porcine bowel in the following conditions: (T1: deactivated tactile feedback; T2: activated tactile feedback; and T3: deactivated tactile feedback). The grasping force, incidence of tissue damage, and the correlation of grasping force and tissue damage were analyzed. Tissue damage was evaluated both grossly and histologically by a pathologist blinded to the sample. RESULTS: Tactile feedback resulted in significantly decreased grasping forces for both experts and novices (P < 0.001 in both conditions). The overall incidence of tissue damage was significantly decreased in all subjects (P < 0.001). A statistically significant correlation was found between grasping forces and incidence of tissue damage (P = 0.008). The decreased forces and tissue damage were retained through the third trial when the system was deactivated (P > 0.05 in all subjects). CONCLUSION: The in vivo application of integrated tactile feedback in the robotic system demonstrates significantly reduced grasping forces, resulting in significantly less tissue damage. This tactile feedback system may improve surgical outcomes and broaden the use of robotic-assisted minimally invasive surgery.
Assuntos
Retroalimentação , Intestinos/cirurgia , Procedimentos Cirúrgicos Robóticos/instrumentação , Cirurgiões , Tato , Animais , Retroalimentação Sensorial , Força da Mão , Intestinos/lesões , Laparoscopia/instrumentação , Laparoscopia/métodos , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Modelos Anatômicos , Procedimentos Cirúrgicos Robóticos/métodos , SuínosRESUMO
Malignant pleural mesothelioma (MPM) is a rare malignancy of the pleura that is frequently resistant to conventional therapies. Immunotherapy is a promising investigational approach for MPM that has shown some evidence of clinical benefit in select patients. However, tumor-induced immunosuppression is likely a major impediment to achieving optimal clinical responses to immunotherapeutic intervention. MPM contains a variable degree of infiltrating T-regulatory cells and M2 macrophages, which are believed to facilitate tumor evasion from the host immune system. Additional immunosuppressive factors identified in other human tumor types, such as tumor-associated programmed death ligand-1 expression, may be relevant for investigation in MPM. Conventional cytoreductive therapies, such as radiation, chemotherapy, and surgery, may play a critical role in successful immunotherapeutic strategies by ablating intratumoral and/or systemic immunosuppressive factors, thus creating a host environment more amenable to immunotherapy. This article reviews the immunotherapeutic approaches being evaluated in patients with MPM and discusses how immunotherapy might be rationally combined with conventional tumor cytoreductive therapies for this disease.
Assuntos
Neoplasias Pulmonares/imunologia , Neoplasias Pulmonares/terapia , Mesotelioma/imunologia , Mesotelioma/terapia , Neoplasias Pleurais/imunologia , Neoplasias Pleurais/terapia , Animais , Ensaios Clínicos Fase II como Assunto , Ensaios Clínicos Fase III como Assunto , Humanos , Imunoterapia/métodos , Mesotelioma Maligno , Ensaios Clínicos Controlados Aleatórios como AssuntoRESUMO
INTRODUCTION: Persistent bacterial infection prolongs hospitalizations, leading to increased healthcare costs. Treatment of these infections costs several billion dollars annually. Biofilm production is one mechanism by which bacteria become resistant. With the help of biofilms, bacteria withstand the host immune response and are much less susceptible to antibiotics. Currently, there is interest in the use of laser-generated shockwaves (LGS) to delaminate biofilm from infected wound surfaces; however, the safety of such an approach has not yet been established. Of particular concern are the thermal and mechanical effects of the shockwave treatment on the epidermis and the underlying collagen structure of the dermis. The present study is a preliminary investigation of the effect of LGS on freshly harvested ex vivo porcine skin tissue samples. MATERIALS AND METHODS: Tissue samples for investigation were harvested immediately post-mortem and treated with LGS within 30 minutes. Previous studies have shown that laser fluences between 100 and 500 mJ/pulse are capable of delaminating biofilms off a variety of surfaces, thus our preliminary investigation focused on this range of laser energy. For each sample, LGS were produced via laser irradiation of a thin layer (0.5 µm) of titanium sandwiched between a 50 and 100 µm thick layer of water glass and a 0.1 mm thick sheet of Mylar. The rapid thermal expansion of the irradiated titanium film generates a transient compressive wave that is coupled through a liquid layer to the surface of the ex vivo pigskin sample. Shocked samples were immediately fixed in formalin and prepared for histological analysis. A blinded pathologist evaluated and scored each section on the basis of its overall appearance (O) and presence of linear/slit-like spaces roughly parallel to the surface of the skin (S). The scores were given on a scale of 0-3. RESULTS: The present investigation revealed no visible difference between the tissue sections of the control sample and those that were subjected to laser-generated shockwaves. There was no relationship between the scores received by the samples and the energy with which they were shocked. CONCLUSION: Preliminary investigation into the safety of the LGS treatment for biofilm delamination appears promising. Additional investigation will continue on ex vivo porcine samples, followed by an in vivo animal trial to better understand the physiological response to LGS treatment.
Assuntos
Biofilmes/efeitos da radiação , Lasers de Estado Sólido , Pele/microbiologia , Pele/efeitos da radiação , Animais , Técnicas In Vitro , SuínosRESUMO
BACKGROUND: Laparoscopic minimally invasive surgery has revolutionized surgical care by reducing trauma to the patient, thereby decreasing the need for medication and shortening recovery times. During open procedures, surgeons can directly feel tissue characteristics. However, in laparoscopic surgery, tactile feedback during grip is attenuated and limited to the resistance felt in the tool handle. Excessive grip force during laparoscopic surgery can lead to tissue damage. Providing additional supplementary tactile feedback may allow subjects to have better control of grip force and identification of tissue characteristics, potentially decreasing the learning curve associated with complex minimally invasive techniques. METHODS: A tactile feedback system has been developed and integrated into a modified laparoscopic grasper that allows forces applied at the grasper tips to be felt by the surgeon's hands. In this study, 15 subjects (11 novices, 4 experts) were asked to perform single-handed peg transfers using these laparoscopic graspers in three trials (feedback OFF, ON, OFF). Peak and average grip forces (newtons) during each grip event were measured and compared using a Wilcoxon ranked test in which each subject served as his or her own control. RESULTS: After activating the tactile feedback system, the novice subject population showed significant decreases in grip force (p < 0.003). When the system was deactivated for the third trial, there were significant increases in grip force (p < 0.003). Expert subjects showed no significant improvements with the addition of tactile feedback (p > 0.05 in all cases). CONCLUSION: Supplementary tactile feedback helped novice subjects reduce grip force during the laparoscopic training task but did not offer improvements for the four expert subjects. This indicates that tactile feedback may be beneficial for laparoscopic training but has limited long-term use in the nonrobotic setting.
Assuntos
Retroalimentação , Força da Mão , Laparoscopia/educação , Laparoscopia/instrumentação , Tato , Competência Clínica , Desenho de Equipamento , HumanosRESUMO
A novel light-weight multi-channel multi-wavelength ultra-low power near infrared spectroscopy (NIRS) system was designed and tested. The NIRS system was designed for clinical use to emit low power (maximum 5 mW) red and near infrared (NIR) light into human tissue and acquire, record, and display reflected light from various tissue depths. In this paper, results of initial functional tests of the system are presented. Potential clinical applications of the NIRS system include long-term non-invasive monitoring of functional activity in tissues, oxygen consumption in skeletal muscles, and tissue blood perfusion.
Assuntos
Diagnóstico por Computador/instrumentação , Monitorização Ambulatorial/instrumentação , Processamento de Sinais Assistido por Computador/instrumentação , Espectroscopia de Luz Próxima ao Infravermelho/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , MiniaturizaçãoRESUMO
A prototype Low Intensity Focused Ultrasound (LIFU) stimulator system was developed to evaluate non-invasive neuromodulation in a large animal model. We conducted a feasibility study on a Göttingen minipig, demonstrating reversible, targeted transcranial neuromodulation. The hypothalamus of the minipig was repeatedly stimulated with LIFU which evoked temporally correlated increases in both heart rate and blood pressure.
Assuntos
Simulação por Computador , Hipotálamo/diagnóstico por imagem , Ultrassom/métodos , Ultrassonografia/métodos , Animais , Estudos de Viabilidade , Modelos Animais , SuínosRESUMO
Bacterial biofilm-related infections are a burden on the healthcare industry. The effect of laser generated shockwaves through polycarbonate, a flexible polymer, is explored for its ability to generate high peak stresses, and also for its ability to conform to complex wound surfaces. Shockwave pulses in Al coated polycarbonate substrates and a resulting peak stress of greater than 60 MPa was measured which should provide sufficient pressure to kill bacteria.
Assuntos
Fenômenos Fisiológicos Bacterianos/efeitos da radiação , Biofilmes/crescimento & desenvolvimento , Biofilmes/efeitos da radiação , Desinfecção/métodos , Lasers , Membranas Artificiais , Polímeros/efeitos da radiaçãoRESUMO
A tactile feedback system has been developed in order to provide augmentative sensory feedback for a number of medical applications. The key component to the system is a pneumatic balloon-based tactile display, which can be scaled and adapted for a variety of configurations. The system also features pneumatic and electronic control system components, a commercial force sensor modified to fit the desired application. To date, this technology has been successfully applied to medical robotics, minimally invasive surgery, and rehabilitation medicine.
Assuntos
Biorretroalimentação Psicológica/instrumentação , Biorretroalimentação Psicológica/fisiologia , Sistemas Homem-Máquina , Estimulação Física/instrumentação , Tato/fisiologia , Biorretroalimentação Psicológica/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Estimulação Física/métodos , Estresse MecânicoRESUMO
A reflective THz imaging system sensitive to small variations in water concentrations has been developed. Biological tissues such as skin, eyes and teeth were imaged to ascertain the systems response to tissue hydration. Difference in water concentrations translated to contrast in the THz images. Contrast was also seen in THz images of skin cancer and burns suggesting the potential diagnostic capability of THz imaging system in clinical settings. All specimens analyzed were freshly excised ex-vivo tissues. These encouraging preliminary results have motivated us to explore the in vivo potential of our imaging system.
Assuntos
Algoritmos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imagem Terahertz/métodos , Humanos , Reprodutibilidade dos Testes , Sensibilidade e EspecificidadeRESUMO
Many existing refreshable Braille display technologies are costly or lack robust performance. A process has been developed to fabricate consistent and reliable pneumatic balloon actuators at low material cost, using a novel manufacturing process. This technique has been adapted for use in refreshable Braille displays that feature low power consumption, ease of manufacture and small form factor. A prototype refreshable cell, conforming to American Braille standards, was developed and tested. The cell was fabricated from molded PDMS to form balloon actuators with a spin-coated silicone film, and fast pneumatic driving elements and an electronic control system were developed to drive the Braille dots. Perceptual testing was performed to determine the feasibility of the approach using a single blind human subject. The subject was able to detect randomized Braille letters rapidly generated by the actuator with 100% character detection accuracy.
Assuntos
Cegueira , Apresentação de Dados , Dispositivos de Compressão Pneumática Intermitente , Leitura , Auxiliares Sensoriais , Tato , Simulação por Computador , Retroalimentação , Humanos , Interface Usuário-ComputadorRESUMO
A tactile feedback system has been developed using silicone-based pneumatic balloon actuators and piezoelectric force sensors, paired with a pneumatic control system. This system has been fitted directly onto the da Vinci surgical robotic system, allowing the forces applied at the robotic end-effectors to be felt on the fingers of surgeons or other system operators. Preliminary system tests have been performed to evaluate the efficacy of the system and to validate the tactile feedback approach. The actuators and pneumatic system had a sufficiently low footprint such that they did not hinder movements during surgical task performance. Preliminary studies using a pressure-indicating phantom suggested that grip force may be reduced with direct tactile-to-tactile feedback. An additional study found that a six element tactile sensing array can effectively provide spatial information to the fingers. The results of these studies are summarized in this paper.
Assuntos
Retroalimentação , Robótica/instrumentação , Auxiliares Sensoriais , Cirurgia Assistida por Computador/instrumentação , Tato , Desenho de Equipamento , Humanos , Silicones , Interface Usuário-ComputadorRESUMO
Terahertz imaging has shown promise as a tool for noninvasive in-vivo detection of skin abnormalities, including skin cancer, burns, scars, and wounds due to its low non-ionizing photon energy and ability to penetrate clothing and gauze. This study examines whether low-level bulk differences in the water content between hyperhydrated and dehydrated skin can be detected using a scanning, reflective THz imaging system. Our results show an 8.7 x difference in the THz reflectivity between hyperhydrated and dehydrated specimens of chicken skin. The results provide further evidence that water concentration is the primary contrast mechanism in reflective THz biomedical imaging.
Assuntos
Desidratação/diagnóstico , Pele/patologia , Espectroscopia Terahertz/instrumentação , Água/metabolismo , Desidratação/diagnóstico por imagem , Diagnóstico por Imagem/métodos , Humanos , Radiografia , Pele/metabolismoRESUMO
As robotic surgery has increased in popularity, the lack of haptic feedback has become a growing issue due to the application of excessive forces that may lead to clinical problems such as intraoperative and postoperative suture breakage. Previous suture breakage warning systems have largely depended on visual and/or auditory feedback modalities, which have been shown to increase cognitive load and reduce operator performance. This work catalogues a new sensing technology and haptic feedback system (HFS) that can reduce instances of suture failure without negatively impacting performance outcomes including knot quality. Suture breakage is common in knot-tying as the pulling motion introduces prominent shear forces. A shear sensor mountable on the da Vinci robotic surgical system's Cadiere grasper detects forces that correlate to the suture's internal tension. HFS then provides vibration feedback to the operator as forces near a particular material's failure load. To validate the system, subjects tightened a total of four knots, two with the Haptic Feedback System (HFS) and two without feedback. The number of suture breakages were recorded and knot fidelity was evaluated by measuring knot slippage. Results showed that instances of suture failure were significantly reduced when HFS was enabled (p = 0.0078). Notably, knots tied with HFS also showed improved quality compared to those tied without feedback (p = 0.010). The results highlight the value of HFS in improving robotic procedure outcomes by reducing instances of suture failures, producing better knots, and reducing the need for corrective measures.