Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Magn Reson Med ; 91(5): 2028-2043, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38173304

RESUMO

PURPOSE: To develop a framework that jointly estimates rigid motion and polarizing magnetic field (B0 ) perturbations ( δ B 0 $$ \delta {\mathbf{B}}_{\mathbf{0}} $$ ) for brain MRI using a single navigator of a few milliseconds in duration, and to additionally allow for navigator acquisition at arbitrary timings within any type of sequence to obtain high-temporal resolution estimates. THEORY AND METHODS: Methods exist that match navigator data to a low-resolution single-contrast image (scout) to estimate either motion or δ B 0 $$ \delta {\mathbf{B}}_{\mathbf{0}} $$ . In this work, called QUEEN (QUantitatively Enhanced parameter Estimation from Navigators), we propose combined motion and δ B 0 $$ \delta {\mathbf{B}}_{\mathbf{0}} $$ estimation from a fast, tailored trajectory with arbitrary-contrast navigator data. To this end, the concept of a quantitative scout (Q-Scout) acquisition is proposed from which contrast-matched scout data is predicted for each navigator. Finally, navigator trajectories, contrast-matched scout, and δ B 0 $$ \delta {\mathbf{B}}_{\mathbf{0}} $$ are integrated into a motion-informed parallel-imaging framework. RESULTS: Simulations and in vivo experiments show the need to model δ B 0 $$ \delta {\mathbf{B}}_{\mathbf{0}} $$ to obtain accurate motion parameters estimated in the presence of strong δ B 0 $$ \delta {\mathbf{B}}_{\mathbf{0}} $$ . Simulations confirm that tailored navigator trajectories are needed to robustly estimate both motion and δ B 0 $$ \delta {\mathbf{B}}_{\mathbf{0}} $$ . Furthermore, experiments show that a contrast-matched scout is needed for parameter estimation from multicontrast navigator data. A retrospective, in vivo reconstruction experiment shows improved image quality when using the proposed Q-Scout and QUEEN estimation. CONCLUSIONS: We developed a framework to jointly estimate rigid motion parameters and δ B 0 $$ \delta {\mathbf{B}}_{\mathbf{0}} $$ from navigators. Combing a contrast-matched scout with the proposed trajectory allows for navigator deployment in almost any sequence and/or timing, which allows for higher temporal-resolution motion and δ B 0 $$ \delta {\mathbf{B}}_{\mathbf{0}} $$ estimates.


Assuntos
Algoritmos , Imageamento por Ressonância Magnética , Estudos Retrospectivos , Movimento (Física) , Imageamento por Ressonância Magnética/métodos , Neuroimagem , Artefatos , Processamento de Imagem Assistida por Computador/métodos , Encéfalo/diagnóstico por imagem
2.
Magn Reson Med ; 2024 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-38968093

RESUMO

PURPOSE: T1 mapping and T1-weighted contrasts have a complimentary but currently under utilized role in fetal MRI. Emerging clinical low field scanners are ideally suited for fetal T1 mapping. The advantages are lower T1 values which results in higher efficiency and reduced field inhomogeneities resulting in a decreased requirement for specialist tools. In addition the increased bore size associated with low field scanners provides improved patient comfort and accessibility. This study aims to demonstrate the feasibility of fetal brain T1 mapping at 0.55T. METHODS: An efficient slice-shuffling inversion-recovery echo-planar imaging (EPI)-based T1-mapping and postprocessing was demonstrated for the fetal brain at 0.55T in a cohort of 38 fetal MRI scans. Robustness analysis was performed and placental measurements were taken for validation. RESULTS: High-quality T1 maps allowing the investigation of subregions in the brain were obtained and significant correlation with gestational age was demonstrated for fetal brain T1 maps ( p < 0 . 05 $$ p<0.05 $$ ) as well as regions-of-interest in the deep gray matter and white matter. CONCLUSIONS: Efficient, quantitative T1 mapping in the fetal brain was demonstrated on a clinical 0.55T MRI scanner, providing foundations for both future research and clinical applications including low-field specific T1-weighted acquisitions.

3.
Magn Reson Med ; 2024 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-38860530

RESUMO

PURPOSE: This study leverages externally generated Pilot Tone (PT) signals to perform motion-corrected brain MRI for sequences with arbitrary k-space sampling and image contrast. THEORY AND METHODS: PT signals are promising external motion sensors due to their cost-effectiveness, easy workflow, and consistent performance across contrasts and sampling patterns. However, they lack robust calibration pipelines. This work calibrates PT signal to rigid motion parameters acquired during short blocks (˜4 s) of motion calibration (MC) acquisitions, which are short enough to unobstructively fit between acquisitions. MC acquisitions leverage self-navigated trajectories that enable state-of-the-art motion estimation methods for efficient calibration. To capture the range of patient motion occurring throughout the examination, distributed motion calibration (DMC) uses data acquired from MC scans distributed across the entire examination. After calibration, PT is used to retrospectively motion-correct sequences with arbitrary k-space sampling and image contrast. Additionally, a data-driven calibration refinement is proposed to tailor calibration models to individual acquisitions. In vivo experiments involving 12 healthy volunteers tested the DMC protocol's ability to robustly correct subject motion. RESULTS: The proposed calibration pipeline produces pose parameters consistent with reference values, even when distributing only six of these approximately 4-s MC blocks, resulting in a total acquisition time of 22 s. In vivo motion experiments reveal significant ( p < 0.05 $$ p<0.05 $$ ) improved motion correction with increased signal to residual ratio for both MPRAGE and SPACE sequences with standard k-space acquisition, especially when motion is large. Additionally, results highlight the benefits of using a distributed calibration approach. CONCLUSIONS: This study presents a framework for performing motion-corrected brain MRI in sequences with arbitrary k-space encoding and contrast, using externally generated PT signals. The DMC protocol is introduced, promoting observation of patient motion occurring throughout the examination and providing a calibration pipeline suitable for clinical deployment. The method's application is demonstrated in standard volumetric MPRAGE and SPACE sequences.

4.
Magn Reson Med ; 92(3): 1263-1276, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38650351

RESUMO

PURPOSE: Widening the availability of fetal MRI with fully automatic real-time planning of radiological brain planes on 0.55T MRI. METHODS: Deep learning-based detection of key brain landmarks on a whole-uterus echo planar imaging scan enables the subsequent fully automatic planning of the radiological single-shot Turbo Spin Echo acquisitions. The landmark detection pipeline was trained on over 120 datasets from varying field strength, echo times, and resolutions and quantitatively evaluated. The entire automatic planning solution was tested prospectively in nine fetal subjects between 20 and 37 weeks. A comprehensive evaluation of all steps, the distance between manual and automatic landmarks, the planning quality, and the resulting image quality was conducted. RESULTS: Prospective automatic planning was performed in real-time without latency in all subjects. The landmark detection accuracy was 4.2 ± $$ \pm $$ 2.6 mm for the fetal eyes and 6.5 ± $$ \pm $$ 3.2 for the cerebellum, planning quality was 2.4/3 (compared to 2.6/3 for manual planning) and diagnostic image quality was 2.2 compared to 2.1 for manual planning. CONCLUSIONS: Real-time automatic planning of all three key fetal brain planes was successfully achieved and will pave the way toward simplifying the acquisition of fetal MRI thereby widening the availability of this modality in nonspecialist centers.


Assuntos
Encéfalo , Feto , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Humanos , Encéfalo/diagnóstico por imagem , Encéfalo/embriologia , Imageamento por Ressonância Magnética/métodos , Feminino , Gravidez , Feto/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Aprendizado Profundo , Diagnóstico Pré-Natal/métodos , Estudos Prospectivos , Imagem Ecoplanar/métodos , Algoritmos , Interpretação de Imagem Assistida por Computador/métodos
5.
J Pediatr ; 267: 113897, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38171471

RESUMO

OBJECTIVE: To assess the relationships between (1) environmental and demographic factors and executive function (EF) in preschool children with congenital heart disease (CHD) and controls and (2) clinical and surgical risk factors and EF in preschool children with CHD. STUDY DESIGN: At 4-6 years of age, parents of children with CHD (n = 51) and controls (n = 124) completed the Behavior Rating Inventory of Executive Function, Preschool Version questionnaire and the Cognitively Stimulating Parenting Scale (CSPS). Multivariable general linear modeling assessed the relationship between Behavior Rating Inventory of Executive Function, Preschool Version composite scores (Inhibitory Self-Control Index [ISCI], Flexibility Index [FI], and Emergent Metacognition Index [EMI]) and group (CHD/control), sex, age at assessment, gestational age, Index of Multiple Deprivation, and CSPS scores. The relationships between CHD type, surgical factors, and brain magnetic resonance imaging injury rating and ISCI, FI, and EMI scores were assessed. RESULTS: The presence of CHD, age at assessment, sex, and Index of Multiple Deprivation were not associated with EF scores. Lower gestational age was associated with greater ISCI and FI scores, and age at assessment was associated with lower FI scores. Group significantly moderated the relationship between CSPS and EF, such that CSPS significantly predicted EF in children with CHD (ISCI: P = .0004; FI: P = .0015; EMI: P = .0004) but not controls (ISCI: P = .2727; FI: P = .6185; EMI: P = .3332). There were no significant relationships between EF scores and surgical factors, CHD type, or brain magnetic resonance imaging injury rating. CONCLUSIONS: Supporting parents to provide a cognitively stimulating home environment may improve EF in children with CHD. The home and parenting environment should be considered when designing intervention studies aimed at improving EF in this patient group.


Assuntos
Função Executiva , Cardiopatias Congênitas , Humanos , Pré-Escolar , Ambiente Domiciliar , Poder Familiar , Pais , Cardiopatias Congênitas/complicações
6.
Eur Radiol ; 2024 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-38326448

RESUMO

OBJECTIVES: To evaluate the diagnostic performance and reliability of MRI descriptors used for the detection of Ménière's disease (MD) on delayed post-gadolinium MRI. To determine which combination of descriptors should be optimally applied and whether analysis of the vestibular aqueduct (VA) contributes to the diagnosis. MATERIALS AND METHODS: This retrospective single centre case-control study evaluated delayed post-gadolinium MRI of patients with Ménièriform symptoms examined consecutively between Dec 2017 and March 2023. Two observers evaluated 17 MRI descriptors of MD and quantified perilymphatic enhancement (PLE) in the cochlea. Definite MD ears according to the 2015 Barany Society criteria were compared to control ears. Cohen's kappa and diagnostic odds ratio (DORs) were calculated for each descriptor. Forward stepwise logistic regression determined which combination of MRI descriptors would best predict MD ears, and the area under the receiver operating characteristic curve for this model was measured. RESULTS: A total of 227 patients (mean age 48.3 ± 14.6, 99 men) with 96 definite MD and 78 control ears were evaluated. The presence of saccular abnormality (absent, as large as or confluent with the utricle) performed best with a DOR of 292.6 (95% confidence interval (CI), 38.305-2235.058). All VA descriptors demonstrated excellent reliability and with DORs of 7.761 (95% CI, 3.517-17.125) to 18.1 (95% CI, 8.445-39.170). Combining these saccular abnormalities with asymmetric cochlear PLE and an incompletely visualised VA correctly classified 90.2% of cases (sensitivity 84.4%, specificity 97.4%, AUC 0.938). CONCLUSION: Either absent, enlarged or confluent saccules are the best predictors of MD. Incomplete visualisation of the VA adds value to the diagnosis. CLINICAL RELEVANCE STATEMENT: A number of different MRI descriptors have been proposed for the diagnosis of Ménière's disease, but by establishing the optimally performing MRI features and highlighting new useful descriptors, there is an opportunity to improve the diagnostic performance of Ménière's disease imaging. KEY POINTS: • A comprehensive range of existing and novel vestibular aqueduct delayed post-gadolinium MRI descriptors were compared for their diagnostic performance in Ménière's disease. • Saccular abnormality (absent, confluent with or larger than the utricle) is a reliable descriptor and is the optimal individual MRI predictor of Ménière's disease. • The presence of this saccule descriptor or asymmetric perilymphatic enhancement and incomplete vestibular aqueduct visualisation will optimise the MRI diagnosis of Ménière's disease.

7.
Artigo em Inglês | MEDLINE | ID: mdl-39152300

RESUMO

PURPOSE: To compare the calibre of the cochlear (CN), superior vestibular (SVN) and inferior vestibular (IVN) nerves on magnetic resonance imaging (MRI), both between Ménière's Disease (MD) ears and clinical controls, and between inner ears with and without endolymphatic hydrops (EH) on MRI. METHODS: A retrospective case-control study evaluated patients undergoing MRI for suspected hydropic ear disease from 9/2017 to 8/2022. The CN, SVN, IVN and facial nerve (FN) diameters and cross-sectional areas (CSA) were measured on T2-weighted sequences whilst EH was evaluated on delayed post-gadolinium MRI. Absolute nerve calibre (and that relative to the FN) in unilateral definite MD ears (2015 Barany criteria) was compared to that in both asymptomatic contralateral ears and clinical control ears. Nerve calibre in ears with severe cochlear and vestibular EH was compared to ears without EH. t tests or Wilcoxon signed-rank test/Mann-Whitney U test were applied (p < 0.001). RESULTS: 173 patients (mean age 51.3 ± 15.1, 65 men) with 84 MD (62 unilateral) and 62 clinical control ears were studied. Absolute and relative CN dimensions were decreased in both MD ears (CSA and diameter) and the contralateral asymptomatic ears (CSA) when compared to clinical controls (p < 0.001). Absolute nerve dimensions were reduced in both severe vestibular EH (CN, IVN and SVN) and severe cochlear EH (CN) (p < 0.001), however this was not evident when adjusted according to facial nerve calibre. CONCLUSION: There is decreased absolute CN calibre in both symptomatic and asymptomatic MD ears as well as ears with severe cochlear and vestibular EH on MRI.

8.
Sci Rep ; 14(1): 11661, 2024 05 22.
Artigo em Inglês | MEDLINE | ID: mdl-38778122

RESUMO

Gaze estimation is long been recognised as having potential as the basis for human-computer interaction (HCI) systems, but usability and robustness of performance remain challenging . This work focuses on systems in which there is a live video stream showing enough of the subjects face to track eye movements and some means to infer gaze location from detected eye features. Currently, systems generally require some form of calibration or set-up procedure at the start of each user session. Here we explore some simple strategies for enabling gaze based HCI to operate immediately and robustly without any explicit set-up tasks. We explore different choices of coordinate origin for combining extracted features from multiple subjects and the replacement of subject specific calibration by system initiation based on prior models. Results show that referencing all extracted features to local coordinate origins determined by subject start position enables robust immediate operation. Combining this approach with an adaptive gaze estimation model using an interactive user interface enables continuous operation with the 75th percentile gaze errors of 0.7 ∘ , and maximum gaze errors of 1.7 ∘ during prospective testing. There constitute state-of-the-art results and have the potential to enable a new generation of reliable gaze based HCI systems.


Assuntos
Movimentos Oculares , Fixação Ocular , Interface Usuário-Computador , Humanos , Fixação Ocular/fisiologia , Movimentos Oculares/fisiologia , Masculino , Tecnologia de Rastreamento Ocular , Feminino , Adulto
9.
Sci Rep ; 14(1): 6637, 2024 03 19.
Artigo em Inglês | MEDLINE | ID: mdl-38503833

RESUMO

Structural fetal body MRI provides true 3D information required for volumetry of fetal organs. However, current clinical and research practice primarily relies on manual slice-wise segmentation of raw T2-weighted stacks, which is time consuming, subject to inter- and intra-observer bias and affected by motion-corruption. Furthermore, there are no existing standard guidelines defining a universal approach to parcellation of fetal organs. This work produces the first parcellation protocol of the fetal body organs for motion-corrected 3D fetal body MRI. It includes 10 organ ROIs relevant to fetal quantitative volumetry studies. We also introduce the first population-averaged T2w MRI atlas of the fetal body. The protocol was used as a basis for training of a neural network for automated organ segmentation. It showed robust performance for different gestational ages. This solution minimises the need for manual editing and significantly reduces time. The general feasibility of the proposed pipeline was also assessed by analysis of organ growth charts created from automated parcellations of 91 normal control 3T MRI datasets that showed expected increase in volumetry during 22-38 weeks gestational age range.


Assuntos
Feto , Processamento de Imagem Assistida por Computador , Gravidez , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Feto/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Idade Gestacional , Cuidado Pré-Natal
10.
bioRxiv ; 2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-38979235

RESUMO

Cortical gyrification takes place predominantly during the second to third trimester, alongside other fundamental developmental processes, such as the development of white matter connections, lamination of the cortex and formation of neural circuits. The mechanistic biology that drives the formation cortical folding patterns remains an open question in neuroscience. In our previous work, we modelled the in utero diffusion signal to quantify the maturation of microstructure in transient fetal compartments, identifying patterns of change in diffusion metrics that reflect critical neurobiological transitions occurring in the second to third trimester. In this work, we apply the same modelling approach to explore whether microstructural maturation of these compartments is correlated with the process of gyrification. We quantify the relationship between sulcal depth and tissue anisotropy within the cortical plate (CP) and underlying subplate (SP), key transient fetal compartments often implicated in mechanistic hypotheses about the onset of gyrification. Using in utero high angular resolution multi-shell diffusion-weighted imaging (HARDI) from the Developing Human Connectome Project (dHCP), our analysis reveals that the anisotropic, tissue component of the diffusion signal in the SP and CP decreases immediately prior to the formation of sulcal pits in the fetal brain. By back-projecting a map of folded brain regions onto the unfolded brain, we find evidence for cytoarchitectural differences between gyral and sulcal areas in the late second trimester, suggesting that regional variation in the microstructure of transient fetal compartments precedes, and thus may have a mechanistic function, in the onset of cortical folding in the developing human brain.

11.
Nat Commun ; 15(1): 16, 2024 02 08.
Artigo em Inglês | MEDLINE | ID: mdl-38331941

RESUMO

Brain dynamic functional connectivity characterises transient connections between brain regions. Features of brain dynamics have been linked to emotion and cognition in adult individuals, and atypical patterns have been associated with neurodevelopmental conditions such as autism. Although reliable functional brain networks have been consistently identified in neonates, little is known about the early development of dynamic functional connectivity. In this study we characterise dynamic functional connectivity with functional magnetic resonance imaging (fMRI) in the first few weeks of postnatal life in term-born (n = 324) and preterm-born (n = 66) individuals. We show that a dynamic landscape of brain connectivity is already established by the time of birth in the human brain, characterised by six transient states of neonatal functional connectivity with changing dynamics through the neonatal period. The pattern of dynamic connectivity is atypical in preterm-born infants, and associated with atypical social, sensory, and repetitive behaviours measured by the Quantitative Checklist for Autism in Toddlers (Q-CHAT) scores at 18 months of age.


Assuntos
Transtorno Autístico , Recém-Nascido Prematuro , Pré-Escolar , Lactente , Adulto , Humanos , Recém-Nascido , Encéfalo/patologia , Mapeamento Encefálico , Imageamento por Ressonância Magnética
12.
EClinicalMedicine ; 65: 102253, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38106560

RESUMO

Background: Magnetic Resonance (MR) imaging is key for investigation of suspected newborn brain abnormalities. Access is limited in low-resource settings and challenging in infants needing intensive care. Portable ultralow field (ULF) MRI is showing promise in bedside adult brain imaging. Use in infants and children has been limited as brain-tissue composition differences necessitate sequence modification. The aim of this study was to develop neonatal-specific ULF structural sequences and test these across a range of gestational maturities and pathologies to inform future validation studies. Methods: Prospective cohort study within a UK neonatal specialist referral centre. Infants undergoing 3T MRI were recruited for paired ULF (64mT) portable MRI by convenience sampling from the neonatal unit and post-natal ward. Key inclusion criteria: 1) Infants with risk or suspicion of brain abnormality, or 2) preterm and term infants without suspicion of major genetic, chromosomal or neurological abnormality. Exclusions: presence of contra-indication for MR scanning. ULF sequence parameters were optimised for neonatal brain-tissues by iterative and explorative design. Neuroanatomic and pathologic features were compared by unblinded review, informing optimisation of subsequent sequence generations in a step-wise manner. Main outcome: visual identification of healthy and abnormal brain tissues/structures. ULF MR spectroscopy, diffusion, susceptibility weighted imaging, arteriography, and venography require pre-clinical technical development and have not been tested. Findings: Between September 23, 2021 and October 25, 2022, 102 paired scans were acquired in 87 infants; 1.17 paired scans per infant. Median age 9 days, median postmenstrual age 40+2 weeks (range: 31+3-53+4). Infants had a range of intensive care requirements. No adverse events observed. Optimised ULF sequences can visualise key neuroanatomy and brain abnormalities. In finalised neonatal sequences: T2w imaging distinguished grey and white matter (7/7 infants), ventricles (7/7), pituitary tissue (5/7), corpus callosum (7/7) and optic nerves (7/7). Signal congruence was seen within the posterior limb of the internal capsule in 10/11 infants on finalised T1w scans. In addition, brain abnormalities visualised on ULF optimised sequences have similar MR signal patterns to 3T imaging, including injury secondary to infarction (6/6 infants on T2w scans), hypoxia-ischaemia (abnormal signal in basal ganglia, thalami and white matter 2/2 infants on T2w scans, cortical highlighting 1/1 infant on T1w scan), and congenital malformations: polymicrogyria 3/3, absent corpus callosum 2/2, and vermian hypoplasia 3/3 infants on T2w scans. Sequences are susceptible to motion corruption, noise, and ULF artefact. Non-identified pathologies were small or subtle. Interpretation: On unblinded review, optimised portable MR can provide sufficient contrast, signal, and resolution for neuroanatomical identification and detection of a range of clinically important abnormalities. Blinded validation studies are now warranted. Funding: The Bill and Melinda Gates Foundation, the MRC, the Wellcome/EPSRC Centre for Medical Engineering, the MRC Centre for Neurodevelopmental Disorders, and the National Institute for Health Research (NIHR) Biomedical Research Centres based at Guy's and St Thomas' and South London & Maudsley NHS Foundation Trusts and King's College London.

13.
Front Radiol ; 3: 1327075, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38304343

RESUMO

Introduction: Ultra-high field MR imaging offers marked gains in signal-to-noise ratio, spatial resolution, and contrast which translate to improved pathological and anatomical sensitivity. These benefits are particularly relevant for the neonatal brain which is rapidly developing and sensitive to injury. However, experience of imaging neonates at 7T has been limited due to regulatory, safety, and practical considerations. We aimed to establish a program for safely acquiring high resolution and contrast brain images from neonates on a 7T system. Methods: Images were acquired from 35 neonates on 44 occasions (median age 39 + 6 postmenstrual weeks, range 33 + 4 to 52 + 6; median body weight 2.93 kg, range 1.57 to 5.3 kg) over a median time of 49 mins 30 s. Peripheral body temperature and physiological measures were recorded throughout scanning. Acquired sequences included T2 weighted (TSE), Actual Flip angle Imaging (AFI), functional MRI (BOLD EPI), susceptibility weighted imaging (SWI), and MR spectroscopy (STEAM). Results: There was no significant difference between temperature before and after scanning (p = 0.76) and image quality assessment compared favorably to state-of-the-art 3T acquisitions. Anatomical imaging demonstrated excellent sensitivity to structures which are typically hard to visualize at lower field strengths including the hippocampus, cerebellum, and vasculature. Images were also acquired with contrast mechanisms which are enhanced at ultra-high field including susceptibility weighted imaging, functional MRI, and MR spectroscopy. Discussion: We demonstrate safety and feasibility of imaging vulnerable neonates at ultra-high field and highlight the untapped potential for providing important new insights into brain development and pathological processes during this critical phase of early life.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa