Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Lancet Oncol ; 24(1): 45-53, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36493793

RESUMO

BACKGROUND: The European EPI-CT study aims to quantify cancer risks from CT examinations of children and young adults. Here, we assess the risk of brain cancer. METHODS: We pooled data from nine European countries for this cohort study. Eligible participants had at least one CT examination before age 22 years documented between 1977 and 2014, had no previous diagnosis of cancer or benign brain tumour, and were alive and cancer-free at least 5 years after the first CT. Participants were identified through the Radiology Information System in 276 hospitals. Participants were linked with national or regional registries of cancer and vital status, and eligible cases were patients with brain cancers according to WHO International Classification of Diseases for Oncology. Gliomas were analysed separately to all brain cancers. Organ doses were reconstructed using historical machine settings and a large sample of CT images. Excess relative risks (ERRs) of brain cancer per 100 mGy of cumulative brain dose were calculated with linear dose-response modelling. The outcome was the first reported diagnosis of brain cancer after an exclusion period of 5 years after the first electronically recorded CT examination. FINDINGS: We identified 948 174 individuals, of whom 658 752 (69%) were eligible for our study. 368 721 (56%) of 658 752 participants were male and 290 031 (44%) were female. During a median follow-up of 5·6 years (IQR 2·4-10·1), 165 brain cancers occurred, including 121 (73%) gliomas. Mean cumulative brain dose, lagged by 5 years, was 47·4 mGy (SD 60·9) among all individuals and 76·0 mGy (100·1) among people with brain cancer. A significant linear dose-response relationship was observed for all brain cancers (ERR per 100 mGy 1·27 [95% CI 0·51-2·69]) and for gliomas separately (ERR per 100 mGy 1·11 [0·36-2·59]). Results were robust when the start of follow-up was delayed beyond 5 years and when participants with possibly previously unreported cancers were excluded. INTERPRETATION: The observed significant dose-response relationship between CT-related radiation exposure and brain cancer in this large, multicentre study with individual dose evaluation emphasises careful justification of paediatric CTs and use of doses as low as reasonably possible. FUNDING: EU FP7; Belgian Cancer Registry; La Ligue contre le Cancer, L'Institut National du Cancer, France; Ministry of Health, Labour and Welfare of Japan; German Federal Ministry of Education and Research; Worldwide Cancer Research; Dutch Cancer Society; Research Council of Norway; Consejo de Seguridad Nuclear, Generalitat de Catalunya, Spain; US National Cancer Institute; UK National Institute for Health Research; Public Health England.


Assuntos
Neoplasias Encefálicas , Glioma , Neoplasias Induzidas por Radiação , Exposição à Radiação , Criança , Humanos , Masculino , Feminino , Adulto Jovem , Adulto , Estudos de Coortes , Doses de Radiação , Neoplasias Induzidas por Radiação/epidemiologia , Neoplasias Induzidas por Radiação/etiologia , Neoplasias Induzidas por Radiação/patologia , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/epidemiologia , Neoplasias Encefálicas/etiologia , Glioma/diagnóstico por imagem , Glioma/epidemiologia , Glioma/etiologia , Exposição à Radiação/efeitos adversos , Tomografia Computadorizada por Raios X/efeitos adversos , Tomografia Computadorizada por Raios X/métodos
2.
Eur J Vasc Endovasc Surg ; 66(2): 178-185, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37011855

RESUMO

OBJECTIVE: To estimate operator organ doses from fluoroscopically guided infrarenal endovascular aneurysm repair (EVAR) procedures, using the detailed exposure information contained in radiation dose structured reports. METHODS: Conversion factors relating kerma area product (PKA) to primary operator organ doses were calculated using Monte Carlo methods for 91 beam angles and seven x-ray spectra typical of clinical practice. A computer program was written, which selects the appropriate conversion factor for each exposure listed in a structured report and multiplies it by the respective PKA. This system was used to estimate operator doses for 81 EVAR procedures for which structured reports were available. The impact of different shielding scenarios and variations in operator position was also investigated. RESULTS: Without any shielding, the median estimated effective dose was 113 µSv (interquartile range [IQR] 71, 252 µSv). The highest median organ doses were for the colon (154 µSv, IQR 81, 343) and stomach (133 µSv, IQR 76, 307). These dose estimates represent all exposures, including fluoroscopy and non-fluoroscopic digital acquisitions. With minimal shielding provided by 0.25 mm of Pb covering the torso and upper legs, the effective dose was reduced by a factor of around 6. With additional shielding from ceiling and table shields, a 25 to 50 fold reduction in dose is achievable. Estimated doses were highest where the primary beam was pointed directly away from the operator. CONCLUSION: The models suggest that with optimal use of shielding, operator doses can be reduced to levels equivalent to one to two days of natural background exposure and well below statutory dose limits.

3.
J Radiol Prot ; 40(4)2020 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-33017815

RESUMO

The ability of ionising radiation to induce lymphoma is unclear. Here, we present a narrative review of epidemiological evidence of the risk of lymphoma, including chronic lymphocytic leukaemia (CLL) and multiple myeloma (MM), among various exposed populations including atomic bombing survivors, industrial and medical radiation workers, and individuals exposed for medical purposes. Overall, there is a suggestion of a positive dose-dependent association between radiation exposure and lymphoma. The magnitude of this association is highly imprecise, however, with wide confidence intervals frequently including zero risk. External comparisons tend to show similar incidence and mortality rates to the general population. Currently, there is insufficient information on the impact of age at exposure, high versus low linear energy transfer radiation, external versus internal or acute versus chronic exposures. Associations are stronger for males than females, and stronger for non-Hodgkin lymphoma and MM than for Hodgkin lymphoma, while the risk of radiation-induced CLL may be non-existent. This broad grouping of diverse diseases could potentially obscure stronger associations for certain subtypes, each with a different cell of origin. Additionally, the classification of malignancies as leukaemia or lymphoma may result in similar diseases being analysed separately, while distinct diseases are analysed in the same category. Uncertainty in cell of origin means the appropriate organ for dose response analysis is unclear. Further uncertainties arise from potential confounding or bias due to infectious causes and immunosuppression. The potential interaction between radiation and other risk factors is unknown. Combined, these uncertainties make lymphoma perhaps the most challenging malignancy to study in radiation epidemiology.


Assuntos
Leucemia , Linfoma , Neoplasias Induzidas por Radiação , Feminino , Humanos , Leucemia/epidemiologia , Linfoma/epidemiologia , Linfoma/etiologia , Masculino , Neoplasias Induzidas por Radiação/etiologia , Radiação Ionizante , Fatores de Risco
4.
J Radiol Prot ; 40(3): 704-726, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32428884

RESUMO

Endovascular aneurysm repair (EVAR) is a well-established minimally invasive technique that relies on x-ray guidance to introduce a stent through the femoral artery and manipulate it into place. The aim of this study was to estimate patient organ and effective doses from EVAR procedures using anatomically realistic computational phantoms and detailed exposure information from radiation dose structured reports (RDSR). Methods: Lookup tables of conversion factors relating kerma area product (PKA) to organ doses for 49 different beam angles were produced using Monte Carlo simulations (MCNPX2.7) with International Commission on Radiological Protection (ICRP) adult male and female voxel phantoms for EVAR procedures of varying complexity (infra-renal, fenestrated/branched and thoracic EVAR). Beam angle specific correction factors were calculated to adjust doses according to x-ray energy. A MATLAB function was written to find the appropriate conversion factor in the lookup table for each exposure described in the RDSR, perform energy corrections and multiply by the respective exposure PKA. Using this approach, organ doses were estimated for 183 EVAR procedures in which RDSRs were available. A number of simplified dose estimation methodologies were also investigated for situations in which RDSR data are not available. Results: Mean estimated bone marrow doses were 57 (range: 2-247), 86 (2-328) and 54 (8-250) mGy for infra-renal, fenestrated/branched and thoracic EVAR, respectively. Respective effective doses were 27 (1-208), 54 (1-180) and 37 (5-167) mSv. Dose estimates using non-individualised, average conversion factors, along with those produced using the alternative Monte Carlo code PCXMC, yielded reasonably similar results overall, though variation for individual procedures could exceed 100% for some organs. In conclusion, radiation doses from x-ray guided endovascular aneurysm repairs are potentially high, though this must be placed in the context of the life sparing nature and high success rate for this procedure.


Assuntos
Aneurisma/diagnóstico por imagem , Aneurisma/cirurgia , Procedimentos Endovasculares , Órgãos em Risco/efeitos da radiação , Doses de Radiação , Feminino , Fluoroscopia , Humanos , Masculino , Método de Monte Carlo , Imagens de Fantasmas , Stents
5.
J Radiol Prot ; 40(4)2020 Sep 24.
Artigo em Inglês | MEDLINE | ID: mdl-32668420

RESUMO

The HARMONIC project (Health Effects of Cardiac Fluoroscopy and Modern Radiotherapy in Paediatrics) is a European study aiming to improve our understanding of the long-term health risks from radiation exposures in childhood and early adulthood. Here, we present the study design for the cardiac fluoroscopy component of HARMONIC. A pooled cohort of approximately 100 000 patients who underwent cardiac fluoroscopy procedures in Belgium, France, Germany, Italy, Norway, Spain or the UK, while aged under 22 years, will be established from hospital records and/or insurance claims data. Doses to individual organs will be estimated from dose indicators recorded at the time of examination, using a lookup-table-based dosimetry system produced using Monte Carlo radiation transport simulations and anatomically realistic computational phantom models. Information on beam geometry and x-ray energy spectra will be obtained from a representative sample of radiation dose structured reports. Uncertainties in dose estimates will be modelled using 2D Monte Carlo methods. The cohort will be followed up using national registries and insurance records to determine vital status and cancer incidence. Information on organ transplantation (a major risk factor for cancer development in this patient group) and/or other conditions predisposing to cancer will be obtained from national or local registries and health insurance data, depending on country. The relationship between estimated radiation dose and cancer risk will be investigated using regression modelling. Results will improve information for patients and parents and aid clinicians in managing and implementing changes to reduce radiation risks without compromising medical benefits.


Assuntos
Neoplasias , Radiometria , Adulto , Idoso , Criança , Fluoroscopia/efeitos adversos , Humanos , Método de Monte Carlo , Neoplasias/radioterapia , Imagens de Fantasmas , Doses de Radiação , Radiometria/métodos , Fatores de Risco
7.
Eur J Epidemiol ; 33(4): 393-401, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29349586

RESUMO

Children and young adults with heart disease appear to be at increased risk of developing cancer, although the reasons for this are unclear. A cohort of 11,270 individuals, who underwent cardiac catheterizations while aged ≤ 22 years in the UK, was established from hospital records. Radiation doses from cardiac catheterizations and CT scans were estimated. The cohort was matched with the NHS Central Register and NHS Transplant Registry to determine cancer incidence and transplantation status. Standardized incidence ratios (SIR) with associated confidence intervals (CI) were calculated. The excess relative risk (ERR) of lymphohaematopoietic  neoplasia was also calculated using Poisson regression. The SIR was raised for all malignancies (2.32, 95% CI 1.65, 3.17), lymphoma (8.34, 95% CI 5.22, 12.61) and leukaemia (2.11, 95% CI 0.82, 4.42). After censoring transplant recipients, post-transplant, the SIR was reduced to 0.90 (95% CI 0.49, 1.49) for all malignancies. All lymphomas developed post-transplant. The SIR for all malignancies developing 5 years from the first cardiac catheterization (2 years for leukaemia/lymphoma) remained raised (3.01, 95% CI 2.09, 4.19) but was again reduced after censoring transplant recipients (0.98, 95% CI 0.48, 1.77). The ERR per mGy bone marrow dose for lymphohaematopoietic neoplasia was reduced from 0.541 (95% CI 0.104, 1.807) to 0.018 (95% CI - 0.002, 0.096) where transplantation status was accounted for as a time-dependent background risk factor. In conclusion, transplantation appears to be a large contributor to elevated cancer rates in this patient group. This is likely to be mainly due to associated immunosuppression, however, radiation exposure may also be a contributing factor.


Assuntos
Cateterismo Cardíaco/efeitos adversos , Cardiopatias/epidemiologia , Neoplasias Induzidas por Radiação/epidemiologia , Neoplasias/epidemiologia , Transplante de Órgãos/efeitos adversos , Exposição à Radiação/efeitos adversos , Tomografia Computadorizada por Raios X/efeitos adversos , Adolescente , Cateterismo Cardíaco/métodos , Criança , Estudos de Coortes , Feminino , Cardiopatias/complicações , Humanos , Tolerância Imunológica , Incidência , Masculino , Neoplasias/etiologia , Neoplasias/patologia , Doses de Radiação , Padrões de Referência , Sistema de Registros , Fatores de Risco , Tomografia Computadorizada por Raios X/métodos , Transplantados , Raios X , Adulto Jovem
8.
Br J Cancer ; 116(1): 109-116, 2017 01 03.
Artigo em Inglês | MEDLINE | ID: mdl-27824812

RESUMO

BACKGROUND: To project risks of developing cancer and the number of cases potentially induced by past, current, and future computed tomography (CT) scans performed in the United Kingdom in individuals aged <20 years. METHODS: Organ doses were estimated from surveys of individual scan parameters and CT protocols used in the United Kingdom. Frequencies of scans were estimated from the NHS Diagnostic Imaging Dataset. Excess lifetime risks (ELRs) of radiation-related cancer were calculated as cumulative lifetime risks, accounting for survival probabilities, using the RadRAT risk assessment tool. RESULTS: In 2000-2008, ELRs ranged from 0.3 to 1 per 1000 head scans and 1 to 5 per 1000 non-head scans. ELRs per scan were reduced by 50-70% in 2000-2008 compared with 1990-1995, subsequent to dose reduction over time. The 130 750 scans performed in 2015 in the United Kingdom were projected to induce 64 (90% uncertainty interval (UI): 38-113) future cancers. Current practices would lead to about 300 (90% UI: 230-680) future cancers induced by scans performed in 2016-2020. CONCLUSIONS: Absolute excess risks from single exposures would be low compared with background risks, but even small increases in annual CT rates over the next years would substantially increase the number of potential subsequent cancers.


Assuntos
Previsões , Neoplasias Induzidas por Radiação/epidemiologia , Pediatras/tendências , Padrões de Prática Médica/tendências , Tomografia Computadorizada por Raios X/tendências , Adolescente , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Pediatras/estatística & dados numéricos , Padrões de Prática Médica/estatística & dados numéricos , Doses de Radiação , Medição de Risco , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Reino Unido/epidemiologia , Adulto Jovem
9.
Br J Cancer ; 114(4): 388-94, 2016 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-26882064

RESUMO

BACKGROUND: We previously reported evidence of a dose-response relationship between ionising-radiation exposure from paediatric computed tomography (CT) scans and the risk of leukaemia and brain tumours in a large UK cohort. Underlying unreported conditions could have introduced bias into these findings. METHODS: We collected and reviewed additional clinical information from radiology information systems (RIS) databases, underlying cause of death and pathology reports. We conducted sensitivity analyses excluding participants with cancer-predisposing conditions or previous unreported cancers and compared the dose-response analyses with our original results. RESULTS: We obtained information from the RIS and death certificates for about 40% of the cohort (n∼180 000) and found cancer-predisposing conditions in 4 out of 74 leukaemia/myelodysplastic syndrome (MDS) cases and 13 out of 135 brain tumour cases. As these conditions were unrelated to CT exposure, exclusion of these participants did not alter the dose-response relationships. We found evidence of previous unreported cancers in 2 leukaemia/MDS cases, 7 brain tumour cases and 232 in non-cases. These previous cancers were related to increased number of CTs. Exclusion of these cancers reduced the excess relative risk per mGy by 15% from 0.036 to 0.033 for leukaemia/MDS (P-trend=0.02) and by 30% from 0.023 to 0.016 (P-trend<0.0001) for brain tumours. When we included pathology reports we had additional clinical information for 90% of the cases. Additional exclusions from these reports further reduced the risk estimates, but this sensitivity analysis may have underestimated risks as reports were only available for cases. CONCLUSIONS: Although there was evidence of some bias in our original risk estimates, re-analysis of the cohort with additional clinical data still showed an increased cancer risk after low-dose radiation exposure from CT scans in young patients.


Assuntos
Neoplasias Encefálicas/epidemiologia , Leucemia/epidemiologia , Neoplasias Induzidas por Radiação/epidemiologia , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Adolescente , Adulto , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/etiologia , Criança , Estudos de Coortes , Feminino , Humanos , Leucemia/diagnóstico por imagem , Leucemia/etiologia , Masculino , Neoplasias Induzidas por Radiação/diagnóstico por imagem , Neoplasias Induzidas por Radiação/etiologia , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/efeitos adversos , Adulto Jovem
10.
Pediatr Hematol Oncol ; 31(3): 259-67, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24087931

RESUMO

A study was conducted to investigate secondary malignant neoplasm (SMN) occurrence following radiotherapy (RT) for cancer in children and young adults, to examine the spatial distribution of SMNs in relation to the irradiated field, and to evaluate a possible role of bystander effects in SMN distribution. Forty-two SMNs were identified among 7257 subjects diagnosed with cancer while living in Yorkshire, UK. Thirty-two of these occurred in patients receiving RT. Distances between SMN locations and RT field edge were estimated along with dose at SMN site. Expected radiation-induced SMN frequency in remote tissues receiving less than 0.1 Gy was predicted using risk estimates based on atomic bombing data. After a median follow-up period of 7.58 years, patients treated with RT were at a nearly five-fold increased risk of developing a subsequent primary neoplasm than the general population in the 0-29 years age range. The most common type of secondary malignancy associated with RT was of the central nervous system (28%), followed by sarcoma (25%) and leukemia (19%). Considering only solid SMNs developing 5 years or more from treatment, the spatial distribution showed a strong pattern of proximity to the irradiated field, with 68% occurring in-field or within 8 cm of the field edge. The SMN frequency in distant tissues receiving doses of less than 0.1 Gy was low but compatible with local absorbed dose.


Assuntos
Neoplasias Induzidas por Radiação/etiologia , Segunda Neoplasia Primária/etiologia , Neoplasias/radioterapia , Radioterapia/efeitos adversos , Adolescente , Adulto , Criança , Pré-Escolar , Feminino , Seguimentos , Humanos , Lactente , Recém-Nascido , Masculino , Estadiamento de Neoplasias , Neoplasias/patologia , Neoplasias Induzidas por Radiação/patologia , Segunda Neoplasia Primária/patologia , Prognóstico , Estudos Retrospectivos , Fatores de Risco , Adulto Jovem
12.
Health Policy Technol ; 12(1): 100725, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36683762

RESUMO

Objectives: To assess the impact of the COVID-19 pandemic on the volumes of use of diagnostic imaging examinations in the Brazilian Unified Health System (SUS), the only healthcare provider for approximately 160 million people. Methods: We collected the monthly numbers of diagnostic imaging examinations in the years 2019, 2020, and 2021 from a database provided by SUS. Data were collected by specific type of examination across different imaging modalities, both for the outpatient (elective and emergency) and inpatient settings. Results: There was a large reduction in the annual volume of almost all types of diagnostic imaging examinations in SUS in 2020, compared to 2019. Decreases were generally greater among outpatients than in the hospital setting, in which the annual volume of use of most modalities was similar or even higher in 2021 than in the pre-pandemic period. Computed tomography (CT) was the only modality for which use increased in 2020 compared to 2019. In contrast to other types of examinations, the use of chest CT was much higher in both 2020 and 2021 than in the preceding years. The relative changes in diagnostic imaging use in SUS started around March-April 2020, when the pandemic began to get worse in Brazil, and tended to correlate to COVID-19 incidence in Brazil over the following months. Conclusions: The COVID-19 pandemic had a large impact on the use of diagnostic imaging examinations in the SUS. Policies and actions are needed to alleviate the resulting potential adverse health effects and to optimize the use of diagnostic tests in the future.

14.
Radiat Res ; 196(1): 74-99, 2021 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-33914893

RESUMO

Within the European Epidemiological Study to Quantify Risks for Paediatric Computerized Tomography (EPI-CT study), a cohort was assembled comprising nearly one million children, adolescents and young adults who received over 1.4 million computed tomography (CT) examinations before 22 years of age in nine European countries from the late 1970s to 2014. Here we describe the methods used for, and the results of, organ dose estimations from CT scanning for the EPI-CT cohort members. Data on CT machine settings were obtained from national surveys, questionnaire data, and the Digital Imaging and Communications in Medicine (DICOM) headers of 437,249 individual CT scans. Exposure characteristics were reconstructed for patients within specific age groups who received scans of the same body region, based on categories of machines with common technology used over the time period in each of the 276 participating hospitals. A carefully designed method for assessing uncertainty combined with the National Cancer Institute Dosimetry System for CT (NCICT, a CT organ dose calculator), was employed to estimate absorbed dose to individual organs for each CT scan received. The two-dimensional Monte Carlo sampling method, which maintains a separation of shared and unshared error, allowed us to characterize uncertainty both on individual doses as well as for the entire cohort dose distribution. Provided here are summaries of estimated doses from CT imaging per scan and per examination, as well as the overall distribution of estimated doses in the cohort. Doses are provided for five selected tissues (active bone marrow, brain, eye lens, thyroid and female breasts), by body region (i.e., head, chest, abdomen/pelvis), patient age, and time period (1977-1990, 1991-2000, 2001-2014). Relatively high doses were received by the brain from head CTs in the early 1990s, with individual mean doses (mean of 200 simulated values) of up to 66 mGy per scan. Optimization strategies implemented since the late 1990s have resulted in an overall decrease in doses over time, especially at young ages. In chest CTs, active bone marrow doses dropped from over 15 mGy prior to 1991 to approximately 5 mGy per scan after 2001. Our findings illustrate patterns of age-specific doses and their temporal changes, and provide suitable dose estimates for radiation-induced risk estimation in epidemiological studies.


Assuntos
Doses de Radiação , Tomografia Computadorizada por Raios X , Adolescente , Criança , Pré-Escolar , Estudos de Coortes , Europa (Continente)/epidemiologia , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Imagens de Fantasmas
15.
Phys Med ; 46: 140-147, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29519400

RESUMO

Studies suggest iodinated contrast media (ICM) may increase organ dose and blood cell DNA damage for a given X-ray exposure. The impact of ICM on dose/damage to extravascular cells and cancer risks is unclear. METHODS: We used Monte Carlo modelling to investigate the microscopic distribution of absorbed dose outside the lumen of arteries, capillaries and interstitial fluids containing blood and various concentrations of iodine. Models were irradiated with four X-ray spectra representing clinical procedures. RESULTS: For the artery model, The average dose enhancement factors (DEF) to blood were 1.70, 2.38, 7.38, and 12.34 for mass concentrations of iodine in blood (ρiI) of 5, 10, 50 and 100 mg/ml, respectively, compared to 0 mg/ml. Average DEFs were reduced to 1.26, 1.51, 3.48 and 5.56, respectively, in the first micrometre of the vessel wall, falling to 1.01, 1.02, 1.06 and 1.09 at 40-50 µm from the lumen edge. For the capillary models, DEF for extravascular tissues was on average 48% lower than DEF for the whole model, including capillaries. A similar situation was observed for the interstitial model, with DEF to the cell nucleus being 35% lower than DEF for the whole model. CONCLUSIONS: While ICM may modify the absorbed doses from diagnostic X-ray examinations, the effect is smaller than suggested by assays of circulating blood cells or blood dose enhancement. Conversely, the potentially large increase in dose to the endothelium of blood vessels means that macroscopic organ doses may underestimate the risk of radiation induced cardiovascular disease for ICM-enhanced exposures.


Assuntos
Artérias/diagnóstico por imagem , Capilares/diagnóstico por imagem , Meios de Contraste/química , Iodo/química , Doses de Radiação , Radiografia/métodos , Método de Monte Carlo , Radiometria
16.
Heart ; 103(5): 341-346, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-27540181

RESUMO

OBJECTIVES: To estimate the risk of developing cancer in relation to the typical radiation doses received from a range of X-ray guided cardiac catheterisations in children, taking variable survival into account. METHODS: Radiation doses were estimated for 2749 procedures undertaken at five UK hospitals using Monte Carlo simulations. The lifetime attributable risk (LAR) of cancer incidence was estimated using models developed by the Biological Effects of Ionising Radiation committee, based on both normal life expectancy, and as a function of attained age, from 20 to 80 years, to take reduced life expectancy into account. RESULTS: The radiation-related risks from these procedures are dominated by lung and breast cancer (for females). Assuming normal life expectancy, central LAR estimates for cancer incidence, based on median doses, ranged from <1 in 2000 for atrial septal defect occlusions to as high as 1 in 150 for valve replacements. For a reduced life expectancy of 50 years, estimated risks are lower by a factor of around 7. For conditions with especially poor survival (age 20 years), such as hypoplastic left heart syndrome, estimated cancer risks attributable to radiation were <1 in 20 000. CONCLUSIONS: Based on recent UK radiation dose levels, the risk of cancer following cardiac catheterisations is relatively low and strongly modified by survival and the type of procedure. The risk of breast cancer, especially following pulmonary artery angioplasty and valve replacements, is the greatest concern.


Assuntos
Cateterismo Cardíaco/efeitos adversos , Doenças Cardiovasculares/diagnóstico por imagem , Doenças Cardiovasculares/terapia , Neoplasias Induzidas por Radiação/epidemiologia , Doses de Radiação , Exposição à Radiação/efeitos adversos , Radiografia Intervencionista/efeitos adversos , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Angioplastia/efeitos adversos , Neoplasias da Mama/epidemiologia , Cateterismo Cardíaco/mortalidade , Simulação por Computador , Angiografia Coronária/efeitos adversos , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Expectativa de Vida , Masculino , Pessoa de Meia-Idade , Método de Monte Carlo , Neoplasias Induzidas por Radiação/diagnóstico , Neoplasias Induzidas por Radiação/mortalidade , Radiografia Intervencionista/mortalidade , Medição de Risco , Fatores de Risco , Fatores de Tempo , Reino Unido/epidemiologia , Adulto Jovem
17.
Cancer Epidemiol Biomarkers Prev ; 26(5): 804-806, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-28052939

RESUMO

Background: We examined the relationship between estimated radiation dose from CT scans and subsequent Hodgkin lymphoma in the UK pediatric CT scans cohort.Methods: A retrospective, record linkage cohort included patients ages 0 to 21 years who underwent CT scans between 1980 and 2002 and were followed up for cancer or death until 2008. Poisson regression analysis was used to evaluate the relationship between estimated radiation dose (lagged by 2 years) and incident Hodgkin lymphoma diagnosed at least 2 years after the first CT scan.Results: There were 65 incident cases of Hodgkin lymphoma in the cohort of 178,601 patients. Neither estimated red bone marrow dose nor mean lymphocyte dose from CT scans was clearly associated with an increased risk of Hodgkin lymphoma (RR for 20+ mGy vs. <5 mGy = 0.92 (0.38-2.22) Ptrend > 0.5 and 1.44 (0.60-3.48) Ptrend > 0.5), respectively.Conclusions: Radiation exposure from pediatric CT scans 2 or more years before diagnosis was not associated with Hodgkin lymphoma in this large UK cohort.Impact: These findings are consistent with the majority of previous studies, which do not support a link between ionizing radiation and Hodgkin lymphoma. The results contrast our previous positive findings in this cohort for brain tumors and leukemia, both of which are known to be strongly linked to radiation exposure during childhood. Cancer Epidemiol Biomarkers Prev; 26(5); 804-6. ©2017 AACR.


Assuntos
Doença de Hodgkin/epidemiologia , Neoplasias Induzidas por Radiação/epidemiologia , Tomografia Computadorizada por Raios X/efeitos adversos , Adolescente , Criança , Pré-Escolar , Estudos de Coortes , Feminino , Humanos , Incidência , Lactente , Recém-Nascido , Masculino , Estudos Retrospectivos , Reino Unido/epidemiologia , Adulto Jovem
18.
Br J Radiol ; 89(1068): 20160532, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27767331

RESUMO

OBJECTIVE: To describe the medical conditions associated with the use of CT in children or young adults with no previous cancer diagnosis. METHODS: Radiologist reports for scans performed in 1995-2008 in non-cancer patients less than 22 years of age were collected from the radiology information system in 44 hospitals of Great Britain. By semantic search, an automated procedure identified 185 medical conditions within the radiologist reports. Manual validation of a subsample by a paediatric radiologist showed a satisfactory performance of the automatic coding procedure. RESULTS: Medical information was extracted for 37,807 scans; 19.5% scans were performed in children less than 5 years old; 52.0% scans were performed in 2000 or after. Trauma, diseases of the nervous (mainly hydrocephalus) or the circulatory system were each mentioned in 25-30% of scans. Hydrocephalus was mentioned in 19% of all scans, 59% of scans repeated ≥5 times in a year, and was the most frequent condition in children less than 5 years of age. Congenital diseases/malformations, disorders of the musculoskeletal system/connective tissues and infectious or respiratory diseases were each mentioned in 5-10% of scans. Suspicionor diagnosis of benign or malignant tumour was identified in 5% of scans. CONCLUSION: This study describes the medical conditions that likely underlie the use of CT in children in Great Britain. It shows that patients with hydrocephalus may receive high cumulative radiation exposures from CT in early life, i.e. at ages when they are most sensitive to radiation. Advances in knowledge: The majority of scans were unrelated to cancer suspicion. Repeated scans over time were mainly associated with the management of hydrocephalus.


Assuntos
Tomografia Computadorizada por Raios X/estatística & dados numéricos , Adolescente , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Reino Unido , Adulto Jovem
19.
Br J Radiol ; 89(1060): 20150305, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26864156

RESUMO

OBJECTIVE: Although CT scans provide great medical benefits, concerns have been raised about the magnitude of possible associated cancer risk, particularly in children who are more sensitive to radiation than adults. Unnecessary high doses during CT examinations can also be delivered to children, if the scan parameters are not adjusted for patient age and size. We conducted the first survey to directly assess the trends in CT scan parameters and doses for paediatric CT scans performed in Great Britain between 1978 and 2008. METHODS: We retrieved 1073 CT film sets from 36 hospitals. The patients were 0-19 years old, and CT scans were conducted between 1978 and 2008. We extracted scan parameters from each film including tube current-time product [milliampere seconds (mAs)], tube potential [peak kilovoltage (kVp)] and manufacturer and model of the CT scanner. We estimated the mean mAs for head and trunk (chest and abdomen/pelvis) scans, according to patient age (0-4, 5-9, 10-14 and 15-19 years) and scan year (<1990, 1990-1994, 1995-1999 and ≥2000), and then derived the volumetric CT dose index and estimated organ doses. RESULTS: For head CT scans, mean mAs decreased by about 47% on average from before 1990 to after 2000, with the decrease starting around 1990. The mean mAs for head CTs did not vary with age before 1990, whereas slightly lower mAs values were used for younger patients after 1990. Similar declines in mAs were observed for trunk CTs: a 46% decline on an average from before 1990 to after 2000. Although mean mAs for trunk CTs did not vary with age before 1990, the value varied markedly by age, from 63 mAs for age 0-4 years compared with 315 mAs for those aged >15 years after 2000. No material changes in kVp were found. Estimated brain-absorbed dose from head CT scans decreased from 62 mGy before 1990 to approximately 30 mGy after 2000. For chest CT scans, the lung dose to children aged 0-4 years decreased from 28 mGy before 1990 to 4 mGy after 2000. CONCLUSION: We found that mAs for head and trunk CTs was approximately halved starting around 1990, and age-specific mAs was generally used for paediatric scans after this date. These changes will have substantially reduced the radiation exposure to children from CT scans in Great Britain. ADVANCES IN KNOWLEDGE: The study shows that mAs and major organ doses for paediatric CT scans in Great Britain began to decrease around 1990.


Assuntos
Doses de Radiação , Exposição à Radiação/prevenção & controle , Tomografia Computadorizada por Raios X/métodos , Adolescente , Criança , Pré-Escolar , Feminino , Cabeça/efeitos da radiação , Humanos , Lactente , Recém-Nascido , Masculino , Radiometria , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Tronco/efeitos da radiação , Reino Unido , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa