RESUMO
In patients with preserved ejection fraction or right bundle branch block (RBBB) pattern requiring a high percentage of ventricular pacing, His-bundle pacing (HBP) might be an alternative to biventricular pacing, although the high threshold occasionally occurs. We provided a case of the intrinsic RBBB correction by capturing intra-Hisian left bundle branch (LBB) or distal His-bundle with different output settings. LBB pacing had the advantage of a much lower threshold while remained most synchrony as HBP. LBB pacing might be a promisingly safe and effective procedure for patients with high-grade atrioventricular (AV) block and RBBB pattern.
Assuntos
Fascículo Atrioventricular/fisiopatologia , Bloqueio de Ramo/fisiopatologia , Bloqueio de Ramo/terapia , Estimulação Cardíaca Artificial/métodos , Eletrocardiografia/métodos , Sistema de Condução Cardíaco/fisiopatologia , Idoso , Humanos , MasculinoRESUMO
PURPOSE: To evaluate dosimetric properties of intensity-modulated proton therapy (IMPT) for simulated treatment planning in patients with atrial fibrillation (AF) targeting left atrial-pulmonary vein junction (LA-PVJ), in comparison with volumetric-modulated arc therapy (VMAT) and helical tomotherapy (TOMO). METHODS: Ten thoracic 4D-CT scans with respiratory motion and one with cardiac motion were used for the study. Ten respiratory 4D-CTs were planned with VMAT, TOMO, and IMPT for simulated AF. Targets at the LA-PVJ were defined as wide-area circumferential ablation line. A single fraction of 25 Gy was prescribed to all plans. The interplay effects from cardiac motion were evaluated based on the cardiac 4D-CT scan. Dose-volume histograms (DVHs) of the ITV and normal tissues were compared. Statistical analysis was evaluated via one-way Repeated-Measures ANOVA and Friedman's test with Bonferroni's multiple comparisons test. RESULTS: The median volume of ITV was 8.72cc. All plans had adequate target coverage (V23.75Gy ≥ 99%). Compared with VMAT and TOMO, IMPT resulted in significantly lower dose of most normal tissues. For VMAT, TOMO, and IMPT plans, Dmean of the whole heart was 5.52 ± 0.90 Gy, 5.89 ± 0.78 Gy, and 3.01 ± 0.57 Gy (P < 0.001), mean dose of pericardium was 4.74 ± 0.76 Gy, 4.98 ± 0.62 Gy, and 2.59 ± 0.44 Gy (P < 0.001), and D0.03cc of left circumflex artery (LCX) was 13.96 ± 5.45 Gy, 14.34 ± 5.91 Gy, and 8.43 ± 7.24 Gy (P < 0.001), respectively. However, no significant advantage for one technique over the others was observed when examining the D0.03cc of esophagus and main bronchi. CONCLUSIONS: IMPT targeting LA-PVJ for patients with AF has high potential to reduce dose to surrounding tissues compared to VMAT or TOMO. Motion mitigation techniques are critical for a particle-therapy approach.
Assuntos
Fibrilação Atrial , Terapia com Prótons , Veias Pulmonares , Radioterapia de Intensidade Modulada , Fibrilação Atrial/cirurgia , Estudos de Viabilidade , Humanos , Órgãos em Risco , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por ComputadorRESUMO
RATIONALE: Takotsubo syndrome (TTS) is characterized by transient and reversible left ventricular systolic dysfunction, which are often associated with acute physical or emotional stressors. Cancer is one of the comorbidities in TTS, and TTS is even considered as a paraneoplastic syndrome, but its mechanism remains unclear. We report a patient in whom cancer and untreated mental disorders triggered TTS. PATIENT CONCERNS: A 59-year-old man was transferred to the Department of Cardiology because of acute onset of severe chest pain and dyspnea before cystoscopy. He presented with hematuria, had been diagnosed with a high-grade urothelial bladder cancer, and underwent transurethral resection of bladder tumors 4âmonths previously. He had severe anxiety regarding recurrence and death from cancer, especially after the hematuria recurred. DIAGNOSIS: TTS and severe anxiety. INTERVENTIONS: The results of coronary angiography, a left ventriculogram, echocardiography, and the clinical outcome led to the diagnosis of TTS. The patient was treated with extracorporeal membrane oxygenation support, mechanical ventilation, and drugs for heart failure and anxiety. OUTCOMES: Echocardiography showed normal wall motion on day 6 of symptom onset. Six months after symptom onset, the anxiety score was reduced from 12 to 11, and the patient had no episodes of any discomfort, and no evidence of cancer recurrence was observed. LESSONS: Patients with cancer and TTS have a higher level of stress, and physicians need to pay more attention to early screening and early treatment of mental disorders in these patients. Prompt and effective multidisciplinary treatment, including psychological counseling and antianxiety drugs, can improve the prognosis in such cases.
Assuntos
Preparações Farmacêuticas , Cardiomiopatia de Takotsubo , Ansiedade/complicações , Hematúria , Humanos , Masculino , Pessoa de Meia-Idade , Choque Cardiogênico , Cardiomiopatia de Takotsubo/complicações , Cardiomiopatia de Takotsubo/diagnósticoRESUMO
OBJECTIVES: To identify optimal predefined criteria (OPC) for filters of the VisiTag™ module in the CARTO 3 system during pulmonary vein isolation (PVI). METHODS: Thirty patients with atrial fibrillation (AF) who experienced PVI first were enrolled. PVI was accomplished by using a Thermocool SmartTouch catheter. Ablation lesions were tagged automatically as soon as predefined criteria of the VisiTag™ module were met. OPC should be that ablation with the setting resulting in the conduction gap (CG) as few as possible, while contiguous encircling ablation line (CEAL) without the tag gap (TG) on the 3D anatomic model as much as possible. RESULTS: When ablation with parameter setting is being catheter movement with a 3 mm distance limit for at least 20 s and force over time (FOT) being off, there were 60 CEAL without TG on the 3D anatomic model. However, 26 CGs were found. After changing FOT setting to be a minimal force of 5 g with 50% stability time, 22 TGs were displayed. Of them, 20 TGs were accompanied by CGs. On reablation at sites of TG with changed parameter setting, 18 CGs were eliminated when 20 TGs disappeared. When reablation with FOT is being a minimal force of 10 g with 50% stability time, 6 remaining CGs were eliminated. However, there was no CEAL. With a mean of follow-up 10.93 months, 2 patients with persistent AF suffered AF recurrence. CONCLUSION: A 3 mm distance limit for at least 20 s and FOT being a minimal force of 5 g with 50% stability time might be OPC for the VisiTag™ module.