1.
Water Environ Res ; 90(2): 110-121, 2018 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-28646570

RESUMO

Inactivation of Bacillus globigii spores in wash water was studied to simulate chlorine inactivation of Bacillus anthracis spores in water generated during biological cleanups. Eight waters were studied, with six containing detergent. Chlorine levels were approximately 3000 mg/L. Results across different waters showed decreasing inactivation with increasing pH. Inactivation did not appear to be influenced by chemical oxygen demand, suspended solids, turbidity, or dissolved solids. Inactivation efficacy was expressed as the time calculated to yield 6 log10 inactivation at 3000 mg NaOCl/L. This time ranged from 5 to 51 minutes at ~21 °C and from 11 to 209 minutes at ~5 °C. For one wash water, inactivation was conducted when there was no pH adjustment, and when the pH was buffered at 7 and 8. Inactivation in these buffered waters was rapid, but inactivation decreased sharply at a pH above ~9.3.


Assuntos
Bacillus/fisiologia , Eliminação de Resíduos Líquidos/métodos , Águas Residuárias/microbiologia , Microbiologia da Água , Bacillus subtilis , Cloro , Desinfetantes , Esporos Bacterianos , Temperatura
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa