Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 81
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Pediatr Radiol ; 54(7): 1187-1196, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38700554

RESUMO

BACKGROUND: Photon-counting computed tomography (PCCT) is a new clinical method that may show better diagnostic quality at lower radiation doses than conventional CT. OBJECTIVE: To investigate the diagnostic quality and radiation dose of paediatric cardiovascular PCCT for diagnosis of congenital heart defects at 70 kV and 90 kV. MATERIALS AND METHODS: This retrospective assessment included clinical non-gated paediatric PCCT examinations for assessment of congenital heart defects. Radiation doses were recorded, and overall and specific diagnostic quality (1-4) were scored by four paediatric radiologists. Agreement, differences, and trends were assessed by percent rater agreement, intraclass correlation, Mann-Whitney tests, and Jonckheere-Terpstra tests. RESULTS: Seventy children with congenital heart defects were examined at 70 kV (n = 35; age 2 days-16 years; 63% boys) or 90 kV (n = 35; age 2 days-17 years; 51% boys). All observers gave a median score of 4 (high diagnostic quality) for both 70 kV and 90 kV, with no difference in median values between tube voltages (all P > 0.06). Agreement for overall scores was 66-94% for 70 kV and 60-77% for 90 kV. Agreement for specific scores was 80-97% for 70 kV and 83-89% for 90 kV. Size-dependent dose estimate was 0.68 mGy (0.25-2.02 mGy) for 70 kV and 1.10 mGy (0.58-2.71 mGy; P < 0.001) for 90 kV. Effective dose was 0.30 mSv (0.15-0.82 mSv) for 70 kV and 0.39 mSv (0.22-1.51 mSv; P = 0.01) for 90 kV. CONCLUSION: Paediatric cardiovascular PCCT yields images for congenital heart defects of high diagnostic quality with low radiation dose at both 70 kV and 90 kV.


Assuntos
Cardiopatias Congênitas , Doses de Radiação , Tomografia Computadorizada por Raios X , Humanos , Cardiopatias Congênitas/diagnóstico por imagem , Feminino , Masculino , Criança , Lactente , Pré-Escolar , Recém-Nascido , Adolescente , Tomografia Computadorizada por Raios X/métodos , Estudos Retrospectivos , Fótons , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
Pediatr Cardiol ; 2024 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-38861174

RESUMO

Hydraulic force aids diastolic filling of the left ventricle (LV) by facilitating basal movement of the atrioventricular plane. The short-axis atrioventricular area difference (AVAD) determines direction and magnitude of this force. Patients with atrial septal defect (ASD) have reduced LV filling due to the left-to-right shunt across the atrial septum and thus potentially altered hydraulic force. The aims were therefore to use cardiac magnetic resonance images to assess whether AVAD and thus the hydraulic force differ in children with ASD compared to healthy children, and if it improves after ASD closure. Twenty-two children with ASD underwent cardiac magnetic resonance before ASD closure. Of these 22 children, 17 of them repeated their examination also after ASD closure. Twelve controls were included. Left atrial and ventricular areas were delineated in short-axis images, and AVAD was defined as the largest ventricular area minus the largest atrial area at each time frame and normalized to body height (AVADi). At end diastole AVADi was positive in all participants, suggesting a force acting towards the atrium assisting the diastolic movement of the atrioventricular plane; however, lower in children both before (6.3 cm2/m [5.2-8.0]; p < 0.0001) and after ASD closure (8.7 cm2/m [6.6-8.5]; p = 0.0003) compared to controls (12.2 cm2/m [11.3-13.9]). Left ventricular diastolic function improves after ASD closure in children by means of improved hydraulic force assessed by AVAD. Although AVADi improved after ASD closure, it was still lower than in controls, indicating diastolic abnormality even after ASD closure. In patients where AVADi is low, ASD closure may help avoid diastolic function deterioration and improve outcome. This could likely be important also in patients with small shunt volumes, especially if they are younger, who currently do not undergo ASD closure. Changes in clinical routine may be considered pending larger outcome studies.

3.
Pediatr Cardiol ; 2024 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-38806793

RESUMO

A hydraulic force aids diastolic filling of the left ventricle (LV) and is proportional to the difference in short-axis area between the left ventricle and atrium; the atrioventricular area difference (AVAD). Patients with repaired Tetralogy of Fallot (rToF) and pulmonary regurgitation (PR) have reduced LV filling which could lead to a negative AVAD and a hydraulic force impeding diastolic filling. The aim was to assess AVAD and to determine whether the hydraulic force aids or impedes diastolic filling in patients with rToF and PR, compared to controls. Twelve children with rToF (11.5 [9-13] years), 12 pediatric controls (10.5 [9-13] years), 12 adults with rToF (21.5 [19-27] years) and 12 adult controls (24 [21-29] years) were retrospectively included. Cine short-axis images were acquired using cardiac magnetic resonance imaging. Atrioventricular area difference was calculated as the largest left ventricular short-axis area minus the largest left atrial short-axis area at beginning of diastole and end diastole and indexed to height (AVADi). Children and adults with rToF and PR had higher AVADi (0.3 cm2/m [- 1.3 to 0.8] and - 0.6 [- 1.5 to - 0.2]) at beginning of diastole compared to controls (- 2.7 cm2/m [- 4.9 to - 1.7], p = 0.015) and - 3.3 cm2/m [- 3.8 to - 2.8], p = 0.017). At end diastole AVADi did not differ between patients and controls. Children and adults with rToF and pulmonary regurgitation have an atrioventricular area difference that do not differ from controls and thus a net hydraulic force that contributes to left ventricular diastolic filling, despite a small underfilled left ventricle due to pulmonary regurgitation.

4.
Magn Reson Med ; 89(2): 594-604, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36156292

RESUMO

PURPOSE: To explore a fetal 3D cardiovascular cine acquisition using a radial image acquisition and compressed-sensing reconstruction and compare image quality and scan time with conventional multislice 2D imaging. METHODS: Volumetric fetal cardiac data were acquired in 26 volunteers using a radial 3D balanced SSFP pulse sequence. Cardiac gating was performed using a Doppler ultrasound device. Images were reconstructed using a parallel-imaging and compressed-sensing algorithm. Multiplanar reformatting to standard cardiac views was performed before image analysis. Clinical 2D images were used for comparison. Qualitative and quantitative image evaluation were performed by two experienced observers (scale: 1-4). Volumes, mass, and function were assessed. RESULTS: Average scan time for the 3D imaging was 6 min, including one localizer. A 2D imaging stack covering the entire heart including localizer sequences took at least 6.5 min, depending on planning complexity. The 3D acquisition was successful in 7 of 26 subjects (27%). Overall image contrast and perceived resolution were lower in the 3D images. Nonetheless, the 3D images had, on average, a moderate cardiac diagnostic quality (median [range]: 3 [1-4]). Standard clinical 2D acquisitions had a high cardiac diagnostic quality (median [range]: 4 [3, 4]). Cardiac measurements were not different between 2D and 3D images (all p > 0.16). CONCLUSION: The presented free-breathing whole-heart fetal 3D radial cine MRI acquisition and reconstruction method enables retrospective visualization of all cardiac views while keeping examination times short. This proof-of-concept work produced images with diagnostic quality, while at the same time reducing the planning complexity to a single localizer.


Assuntos
Interpretação de Imagem Assistida por Computador , Imageamento Tridimensional , Humanos , Imageamento Tridimensional/métodos , Interpretação de Imagem Assistida por Computador/métodos , Estudos Retrospectivos , Suspensão da Respiração , Imagem Cinética por Ressonância Magnética/métodos
5.
Magn Reson Med ; 90(6): 2472-2485, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37582228

RESUMO

PURPOSE: To ultimately make accurate and precise fetal noninvasive oxygen saturation (sO2 ) measurements by T2 -prepared bSSFP more widely available by systematically assessing error sources in order to potentially reduce perinatal mortality in cardiovascular malformations and fetal growth restriction. METHODS: T2 -prepared bSSFP data were acquired in phantoms; in flowing blood in adults in the superior sagittal sinus, ascending and descending aorta, and main pulmonary artery; and in the fetal descending aorta and umbilical vein. T2 was assessed in relation to T2 two- or three-parameter curve-fitting techniques, SSFP readout, refocusing time delay (τ), constant and pulsatile blood flow, and impact of T1 recovery. Further, fetal T2 and sO2 variability were quantified in the descending aorta and umbilical vein in healthy fetuses and fetuses with cardiovascular malformation (gestational weeks 32-38). RESULTS: In phantoms, three-parameter fitting was accurate irrespective of phase FOV (<4 ms; i.e., <2%), and T2 was overestimated (up to 23 ms/10%; p = 0.001) beyond ±30 Hz off-resonance. In the adult aorta, T2 was underestimated during higher blood flow velocities and pulsatility for τ = 16 ms (-41 ms/-17%; p = 0.008). In fetuses, two-parameter fitting overestimated T2 compared with three-parameter fitting (+33 ms/+18%; p = 0.03). T2 variability was 18 ms/15% in the fetal descending aorta and 28 ms/14% in the umbilical vein. The resulting estimated sO2 variability was ∼10% (15% of sO2 value) in the fetal descending aorta. CONCLUSIONS: Errors due to T2 -fitting techniques, off-resonance, flow velocity, and insufficient T1 recovery between image acquisitions could be mitigated by using three-parameter fitting with included saturation-prepared images approximating infinite T2 -preparation time, adequate shimming covering the fetus and placenta, and by modifying acquisition parameters. Variability in fetal blood T2 and sO2 , however, indicate that it is currently not feasible to use these methods for prediction of disease.


Assuntos
Sangue Fetal , Saturação de Oxigênio , Gravidez , Feminino , Adulto , Humanos , Feto/diagnóstico por imagem , Hemodinâmica/fisiologia , Velocidade do Fluxo Sanguíneo/fisiologia , Oxigênio
6.
J Magn Reson Imaging ; 57(1): 71-82, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35726779

RESUMO

BACKGROUND: Neonates with critical congenital heart disease require early intervention. Four-dimensional (4D) flow may facilitate surgical planning and improve outcome, but accuracy and precision in neonates are unknown. PURPOSE: To 1) validate two-dimensional (2D) and 4D flow MRI in a phantom and investigate the effect of spatial and temporal resolution; 2) investigate accuracy and precision of 4D flow and internal consistency of 2D and 4D flow in neonates; and 3) compare scan time of 4D flow to multiple 2D flows. STUDY TYPE: Phantom and prospective patients. POPULATION: A total of 17 neonates with surgically corrected aortic coarctation (age 18 days [IQR 11-20]) and a three-dimensional printed neonatal aorta phantom. FIELD STRENGTH/SEQUENCE: 1.5T, 2D flow and 4D flow. ASSESSMENT: In the phantom, 2D and 4D flow volumes (ascending and descending aorta, and aortic arch vessels) with different resolutions were compared to high-resolution reference 2D flow. In neonates, 4D flow was compared to 2D flow volumes at each vessel. Internal consistency was computed as the flow volume in the ascending aorta minus the sum of flow volumes in the aortic arch vessels and descending aorta, divided by ascending aortic flow. STATISTICAL TESTS: Bland-Altman plots, Pearson correlation coefficient (r), and Student's t-tests. RESULTS: In the phantom, 2D flow differed by 0.01 ± 0.02 liter/min with 1.5 mm spatial resolution and -0.01 ± 0.02 liter/min with 0.8 mm resolution; 4D flow differed by -0.05 ± 0.02 liter/min with 2.4 mm spatial and 42 msec temporal resolution, -0.01 ± 0.02 liter/min with 1.5 mm, 42 msec resolution and -0.01 ± 0.02 liter/min with 1.5 mm, 21 msec resolution. In patients, 4D flow and 2D flow differed by -0.06 ± 0.08 liter/min. Internal consistency in patients was -11% ± 17% for 2D flow and 5% ± 13% for 4D flow. Scan time was 17.1 minutes [IQR 15.5-18.5] for 2D flow and 6.2 minutes [IQR 5.3-6.9] for 4D flow, P < 0.0001. DATA CONCLUSION: Neonatal 4D flow MRI is time efficient and can be acquired with good internal consistency without contrast agents or general anesthesia, thus potentially expanding 4D flow use to the youngest and smallest patients. EVIDENCE LEVEL: 1 TECHNICAL EFFICACY: Stage 2.


Assuntos
Imageamento Tridimensional , Imageamento por Ressonância Magnética , Recém-Nascido , Humanos , Adolescente , Imageamento Tridimensional/métodos , Velocidade do Fluxo Sanguíneo , Estudos Prospectivos , Imageamento por Ressonância Magnética/métodos , Anestesia Geral , Reprodutibilidade dos Testes
7.
Pediatr Res ; 93(7): 2019-2027, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36344695

RESUMO

BACKGROUND: Although preterm birth predisposes for cardiovascular disease, recent studies in children indicate normal blood pressure and arterial stiffness. This prospective cohort study therefore assessed blood pressure and arterial stiffness in adolescents born very preterm due to verified fetal growth restriction (FGR). METHODS: Adolescents (14 (13-17) years; 52% girls) born very preterm with FGR (preterm FGR; n = 24) and two control groups born with appropriate birth weight (AGA), one in similar gestation (preterm AGA; n = 27) and one at term (term AGA; n = 28) were included. 24-hour ambulatory blood pressure and aortic pulse wave velocity (PWV) and distensibility by magnetic resonance imaging were acquired. RESULTS: There were no group differences in prevalence of hypertension or in arterial stiffness (all p ≥ 0.1). In boys, diastolic and mean arterial blood pressures increased from term AGA to preterm AGA to preterm FGR with higher daytime and 24-hour mean arterial blood pressures in the preterm FGR as compared to the term AGA group. In girls, no group differences were observed (all p ≥ 0.1). CONCLUSIONS: Very preterm birth due to FGR is associated with higher, yet normal blood pressure in adolescent boys, suggesting an existing but limited impact of very preterm birth on cardiovascular risk in adolescence, enhanced by male sex and FGR. IMPACT: Very preterm birth due to fetal growth restriction was associated with higher, yet normal blood pressure in adolescent boys. In adolescence, very preterm birth due to fetal growth restriction was not associated with increased thoracic aortic stiffness. In adolescence, very preterm birth in itself showed an existing but limited effect on blood pressure and thoracic aortic stiffness. Male sex and fetal growth restriction enhanced the effect of preterm birth on blood pressure in adolescence. Male sex and fetal growth restriction should be considered as additional risk factors to that of preterm birth in cardiovascular risk stratification.


Assuntos
Hipertensão , Nascimento Prematuro , Criança , Feminino , Humanos , Recém-Nascido , Masculino , Adolescente , Pressão Sanguínea/fisiologia , Estudos Prospectivos , Monitorização Ambulatorial da Pressão Arterial , Análise de Onda de Pulso , Retardo do Crescimento Fetal , Desenvolvimento Fetal , Idade Gestacional
8.
Pediatr Nephrol ; 38(6): 1855-1866, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36409369

RESUMO

BACKGROUND: Preterm birth and fetal growth restriction (FGR) are associated with structural and functional kidney changes, increasing long-term risk for chronic kidney disease and hypertension. However, recent studies in preterm children are conflicting, indicating structural changes but normal kidney function. This study therefore assessed kidney structure and function in a cohort of adolescents born very preterm with and without verified FGR. METHODS: Adolescents born very preterm with FGR and two groups with appropriate birthweight (AGA) were included; one matched for gestational week at birth and one born at term. Cortical and medullary kidney volumes and T1 and T2* mapping values were assessed by magnetic resonance imaging. Biochemical markers of kidney function and renin-angiotensin-aldosterone system (RAAS) activation were analyzed. RESULTS: Sixty-four adolescents were included (13-16 years; 48% girls). Very preterm birth with FGR showed smaller total (66 vs. 75 ml/m2; p = 0.01) and medullary volume (19 vs. 24 ml/m2; p < 0.0001) compared to term AGA. Corticomedullary volume ratio decreased from preterm FGR (2.4) to preterm AGA (2.2) to term AGA (1.9; p = 0.004). There were no differences in T1 or T2* values (all p ≥ 0.34) or in biochemical markers (all p ≥ 0.12) between groups. CONCLUSIONS: FGR with abnormal fetal blood flow followed by very preterm birth is associated with smaller total kidney and medullary kidney volumes, but not with markers of kidney dysfunction or RAAS activation in adolescence. Decreased total kidney and medullary volumes may still precede a long-term decrease in kidney function, and potentially be used as a prognostic marker. A higher resolution version of the Graphical abstract is available as Supplementary information.


Assuntos
Hipertensão , Nascimento Prematuro , Criança , Feminino , Recém-Nascido , Adolescente , Humanos , Masculino , Retardo do Crescimento Fetal/patologia , Peso ao Nascer , Rim/patologia , Idade Gestacional
9.
Pediatr Cardiol ; 44(6): 1311-1318, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36334112

RESUMO

Magnetic resonance imaging (MRI) provides images for estimating fetal volume and weight, but manual delineations are time consuming. The aims were to (1) validate an algorithm to automatically quantify fetal volume by MRI; (2) compare fetal weight by Hadlock's formulas to that of MRI; and (3) quantify fetal blood flow and index flow to fetal weight by MRI. Forty-two fetuses at 36 (29-39) weeks gestation underwent MRI. A neural network was trained to segment the fetus, with 20 datasets for training and validation, and 22 for testing. Hadlock's formulas 1-4 with biometric parameters from MRI were compared with weight by MRI. Blood flow was measured using phase-contrast MRI and indexed to fetal weight. Bland-Altman analysis assessed the agreement between automatic and manual fetal segmentation and the agreement between Hadlock's formulas and fetal segmentation for fetal weight. Bias and 95% limits of agreement were for automatic versus manual measurements 4.5 ± 351 ml (0.01% ± 11%), and for Hadlock 1-4 vs MRI 108 ± 435 g (3% ± 14%), 211 ± 468 g (7% ± 15%), 106 ± 425 g (4% ± 14%), and 179 ± 472 g (6% ± 15%), respectively. Umbilical venous flow was 406 (range 151-650) ml/min (indexed 162 (range 52-220) ml/min/kg), and descending aortic flow was 763 (range 481-1160) ml/min (indexed 276 (range 189-386) ml/min/kg). The automatic method showed good agreement with manual measurements and saves considerable analysis time. Hadlock 1-4 generally agree with MRI. This study also illustrates the confounding effects of fetal weight on absolute blood flow, and emphasizes the benefit of indexed measurements for physiological assessment.


Assuntos
Aprendizado Profundo , Peso Fetal , Humanos , Imageamento por Ressonância Magnética , Feto/diagnóstico por imagem , Idade Gestacional
10.
Pediatr Cardiol ; 2023 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-37596421

RESUMO

Left ventricular shape alterations predict cardiovascular outcomes and have been observed in children born preterm and after fetal growth restriction (FGR). The aim was to investigate whether left ventricular shape is altered in adolescents born very preterm and if FGR has an additive effect. Adolescents born very preterm due to verified early-onset FGR and two control groups with birthweight appropriate for gestational age (AGA), born at similar gestational age and at term, respectively, underwent cardiac MRI. Principal component analysis was applied to find the modes of variation best explaining shape variability for end-diastole, end-systole, and for the combination of both, the latter indicative of function. Seventy adolescents were included (13-16 years; 49% males). Sphericity was increased for preterm FGR versus term AGA for end-diastole (36[0-60] vs - 42[- 82-8]; p = 0.01) and the combined analysis (27[- 23-94] vs - 51[- 119-11]; p = 0.01), as well as for preterm AGA versus term AGA for end-diastole (30[- 56-115] vs - 42[- 82-8]; p = 0.04), for end-systole (57[- 29-89] vs - 30[- 79-34]; p = 0.03), and the combined analysis (44[- 50-145] vs - 51[- 119-11]; p = 0.02). No group differences were observed for left ventricular mass or ejection fraction (all p ≥ 0.33). Sphericity was increased after very preterm birth and exacerbated by early-onset FGR, indicating an additive effect to that of very preterm birth on left ventricular remodeling. Increased sphericity may be a prognostic biomarker of future cardiovascular disease in this cohort that as of yet shows no signs of cardiac dysfunction using standard clinical measurements.

11.
J Magn Reson Imaging ; 56(1): 223-231, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-34652860

RESUMO

BACKGROUND: Fetal cardiac magnetic resonance imaging (MRI) improves the diagnosis of congenital heart defects, but is sensitive to fetal motion due to long image acquisition time. This may be overcome with faster image acquisition with low resolution, followed by image enhancement to provide clinically useful images. PURPOSE: To combine phase-encoding undersampling with super-resolution neural networks to achieve high-resolution fetal cine cardiac MR images with short acquisition time. STUDY TYPE: Prospective. SUBJECTS: Twenty-eight fetuses (gestational week 36 [interquartile range 33-38 weeks]). FIELD STRENGTH/SEQUENCE: 1.5 T, balanced steady-state free precession (bSSFP) cine sequence. ASSESSMENT: Images were acquired using fully sampled Doppler ultrasound-gated clinical bSSFP cine as reference, with equivalent cine sequences with decreased phase-encoding resolution (25%, 33%, and 50% of clinical standard). Two super-resolution methods based on convolutional neural networks were proposed and evaluated (phasrGAN and phasrresnet). Data were partitioned into training (36 cine slices), validation (3 cine slices), and test sets (67 cine slices) without overlap. Conventional reconstruction methods using bicubic interpolation and k-space zeropadding were used for comparison. Three blinded observers scored image quality between 1 and 10. STATISTICAL TESTS: Image scores are reported as median [interquartile range] and were compared using Mann-Whitney's nonparametric test with P < 0.05 showing statistically significant differences. RESULTS: Both proposed methods showed no significant difference in image quality compared to clinical images (8 [7-8.5]) down to 33% (phasrGAN 8 [6.5-8]; phasrresnet 8 [7-8], all P ≥ 0.19) phase-encoding resolution, i.e., up to three times faster image acquisition, whereas bicubic interpolation and k-space zeropadding showed significantly lower quality for 33% phase-encoding resolution (both 7 [6-8]). DATA CONCLUSION: Super-resolution enhancement can be used for fetal cine cardiac MRI to reduce image acquisition time while maintaining image quality. This may lead to an improved success rate for fetal cine MR imaging, as the impact of fetal motion is lessened by shortened acquisitions. LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY: Stage 2.


Assuntos
Aumento da Imagem , Interpretação de Imagem Assistida por Computador , Feminino , Feto/diagnóstico por imagem , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética , Imagem Cinética por Ressonância Magnética/métodos , Estudos Prospectivos , Reprodutibilidade dos Testes
12.
Pediatr Cardiol ; 43(7): 1631-1644, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35396945

RESUMO

Pulse wave velocity (PWV) by cardiovascular magnetic resonance (CMR) lacks standardization. The aim of this study was to investigate methodological aspects of PWV measurements by CMR in neonates and adolescents. A computer phantom was created to validate the temporal resolution required for accurate PWV. Fifteen neonates and 71 adolescents underwent CMR with reference standard 3D angiography and phase-contrast flow acquisitions, and in a subset coronal overview images. Velocity and flow curves, transit time methods (time-to-foot (TTF), maximum upslope, and time-to-peak (TTP)), and baseline correction methods (no correction, automatic and manual) were investigated. In neonates, required timeframes per cardiac cycle for accurate PWV was 42 for the aortic arch and 41 for the thoracic aorta. In adolescents, corresponding values were 39 and 32. Aortic length differences by overview images and 3D angiography in adolescents were - 16-18 mm (aortic arch) and - 25-30 mm (thoracic aorta). Agreement in PWV between automatic and manual baseline correction was - 0.2 ± 0.3 m/s in neonates and 0.0 ± 0.1 m/s in adolescents. Velocity and flow-derived PWV measurements did not differ in either group (all p > 0.08). In neonates, transit time methods did not differ (all p > 0.19) but in adolescents PWV was higher for TTF (3.8 ± 0.5 m/s) and maximum upslope (3.7 ± 0.6 m/s) compared to TTP (2.7 ± 1.0 m/s; p < 0.0001). This study is a step toward standardization of PWV in neonates and adolescents using CMR. It provides required temporal resolution for phase-contrast flow acquisitions for typical heartrates in neonates and adolescents, and supports 3D angiography and time-to-foot with automatic baseline correction for accurate PWV measurements.


Assuntos
Análise de Onda de Pulso , Rigidez Vascular , Adolescente , Aorta/patologia , Velocidade do Fluxo Sanguíneo , Humanos , Recém-Nascido , Imageamento por Ressonância Magnética/métodos , Valor Preditivo dos Testes , Análise de Onda de Pulso/métodos , Reprodutibilidade dos Testes
13.
Am J Physiol Heart Circ Physiol ; 318(2): H345-H353, 2020 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-31886724

RESUMO

Timing and indication for pulmonary valve replacement (PVR) in patients with repaired Tetralogy of Fallot (rToF) and pulmonary regurgitation (PR) are uncertain. To improve understanding of pumping mechanics, we investigated atrioventricular coupling before and after surgical PVR. Cardiovascular magnetic resonance was performed in patients (n = 12) with rToF and PR > 35% before and after PVR and in healthy controls (n = 15). Atrioventricular plane displacement (AVPD), global longitudinal peak systolic strain (GLS), atrial and ventricular volumes, and caval blood flows were analyzed. Right ventricular (RV) AVPD and RV free wall GLS were lower in patients before PVR compared with controls (P < 0.0001; P < 0.01) and decreased after PVR (P < 0.0001 for both). Left ventricular AVPD was lower in patients before PVR compared with controls (P < 0.05) and decreased after PVR (P < 0.01). Left ventricular GLS did not differ between patients and controls (P > 0.05). Right atrial reservoir volume and RV stroke volume generated by AVPD correlated in controls (r = 0.93; P < 0.0001) and patients before PVR (r = 0.88; P < 0.001) but not after PVR. In conclusion, there is a clear atrioventricular coupling in patients before PVR that is lost after PVR, possibly because of loss of pericardial integrity. Impaired atrioventricular coupling complicates assessment of ventricular function after surgery using measurements of longitudinal function. Changes in atrioventricular coupling seen in patients with rToF may be energetically unfavorable, and long-term effects of surgery on atrioventricular coupling is therefore of interest. Also, AVPD and GLS cannot be used interchangeably to assess longitudinal function in rToF.NEW & NOTEWORTHY There is a clear atrioventricular coupling in patients with Tetralogy of Fallot (ToF) and pulmonary regurgitation before surgical pulmonary valve replacement (PVR) that is lost after operation, possibly because of loss of pericardial integrity. The impaired atrioventricular coupling complicates assessment of ventricular function after surgery when using measurements of longitudinal function. Left ventricular atrioventricular plane displacement (AVPD) found differences between patients and controls and changes after PVR that longitudinal strain could not detect. This indicates that AVPD and strain cannot be used interchangeably to assess longitudinal function in repaired ToF.


Assuntos
Implante de Prótese de Valva Cardíaca , Valva Pulmonar/cirurgia , Tetralogia de Fallot/fisiopatologia , Tetralogia de Fallot/cirurgia , Função Ventricular Esquerda , Função Ventricular Direita , Adulto , Teste de Esforço , Feminino , Testes de Função Cardíaca , Humanos , Estudos Longitudinais , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Valva Pulmonar/diagnóstico por imagem , Volume Sistólico , Tetralogia de Fallot/diagnóstico por imagem , Resultado do Tratamento
14.
J Magn Reson Imaging ; 51(1): 260-272, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31228302

RESUMO

BACKGROUND: Fetal cardiovascular MRI complements ultrasound to assess fetal cardiovascular pathophysiology. PURPOSE: To develop a free-breathing method for retrospective fetal cine MRI using Doppler ultrasound (DUS) cardiac gating and tiny golden angle radial sampling (tyGRASP) for accelerated acquisition capable of detecting fetal movements for motion compensation. STUDY TYPE: Feasibility study. SUBJECTS: Nine volunteers (gestational week 34-40). Short-axis and four-chamber views were acquired during maternal free-breathing and breath-hold. FIELD STRENGTH/SEQUENCE: 1.5T cine balanced steady-state free precession. ASSESSMENT: A self-gated reconstruction method was improved for clinical application by using 1) retrospective DUS gating, and 2) motion detection and rejection/correction algorithms for compensating for fetal motion. The free-breathing reconstructions were qualitatively and quantitatively assessed, and DUS-gating was compared with self-gating in breath-hold reconstructions. A scoring of 1-4 for overall image quality, cardiac, and extracardiac diagnostic quality was used. STATISTICAL TESTS: Friedman's test was used to assess differences in qualitative scoring between observers. A Wilcoxon matched-pairs signed rank test was used to assess differences between breath-hold and free-breathing acquisitions and between observers' quantitative measurements. RESULTS: In all cases, 111 free-breathing and 145 breath-hold acquisitions, the automatically calculated DUS-based cardiac gating signal provided reconstructions of diagnostic quality (median score 4, range 1-4). Free-breathing did not affect the DUS-based cardiac gated retrospective radial reconstruction with respect to image or diagnostic quality (all P > 0.06). Motion detection with rejection/correction in k-space produced high-quality free-breathing DUS-based reconstructions [median 3, range (2-4)], whereas free-breathing self-gated methods failed in 80 out of 88 cases to produce a stable gating signal. DATA CONCLUSION: Free-breathing fetal cine cardiac MRI based on DUS gating and tyGRASP with motion compensation yields diagnostic images. This simplifies acquisition for the pregnant woman and thus could help increase fetal cardiac MRI acceptance in the clinic. LEVEL OF EVIDENCE: 2 Technical Efficacy Stage: 1 J. Magn. Reson. Imaging 2020;51:260-272.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca/métodos , Coração Fetal/anatomia & histologia , Imageamento por Ressonância Magnética/métodos , Ultrassonografia Pré-Natal/métodos , Estudos de Viabilidade , Feminino , Humanos , Movimento (Física) , Gravidez , Respiração
15.
Magn Reson Med ; 81(1): 495-503, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30159933

RESUMO

PURPOSE: To validate metric optimized gating phase-contrast MR (MOG PC-MR) flow measurements for a range of fetal flow velocities in phantom experiments. 2) To investigate intra- and interobserver variability for fetal flow measurements at an imaging center other than the original site. METHODS: MOG PC-MR was compared to timer/beaker measurements in a pulsatile flow phantom using a heart rate (∼145 bpm), nozzle diameter (∼6 mm), and flow range (∼130-700 mL/min) similar to fetal imaging. Fifteen healthy fetuses were included for intra- and interobserver variability in the fetal descending aorta and umbilical vein. RESULTS: Phantom MOG PC-MR flow bias and variability was 2% ± 23%. Accuracy of MOG PC-MR was degraded for flow profiles with low velocity-to-noise ratio. Intra- and interobserver coefficients of variation were 6% and 19%, respectively, for fetal descending aorta; and 10% and 17%, respectively, for the umbilical vein. CONCLUSION: Phantom validation showed good agreement between MOG and conventionally gated PC-MR, except for cases with low velocity-to-noise ratio, which resulted in MOG misgating and underestimated peak velocities and warranted optimization of sequence parameters to individual fetal vessels. Inter- and intraobserver variability for fetal MOG PC-MR imaging were comparable to previously reported values.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca , Sistema Cardiovascular/embriologia , Diagnóstico Pré-Natal/métodos , Algoritmos , Aorta Torácica , Velocidade do Fluxo Sanguíneo , Feminino , Coração Fetal , Frequência Cardíaca , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética , Variações Dependentes do Observador , Imagens de Fantasmas , Gravidez , Fluxo Pulsátil , Reprodutibilidade dos Testes , Veias Umbilicais/diagnóstico por imagem , Veias Umbilicais/embriologia
16.
J Cardiovasc Magn Reson ; 21(1): 74, 2019 11 28.
Artigo em Inglês | MEDLINE | ID: mdl-31783877

RESUMO

INTRODUCTION: Fetal cardiovascular magnetic resonance (CMR) imaging is used clinically and for research, but has been previously limited due to lack of direct gating methods. A CMR-compatible Doppler ultrasound (DUS) gating device has resolved this. However, the DUS-gating method is not validated against the current reference method for fetal phase-contrast blood flow measurements, metric optimized gating (MOG). Further, we investigated how different methods for vessel delineation affect flow volumes and observer variability in fetal flow acquisitions. AIMS: To 1) validate DUS gating versus MOG for quantifying fetal blood flow; 2) assess repeatability of DUS gating; 3) assess impact of region of interest (ROI) size on flow volume; and 4) compare time-resolved and static delineations for flow volume and observer variability. METHODS: Phase-contrast CMR was acquired in the fetal descending aorta (DAo) and umbilical vein by DUS gating and MOG in 22 women with singleton pregnancy in gestational week 360 (265-400) with repeated scans in six fetuses. Impact of ROI size on measured flow was assessed for ROI:s 50-150% of the vessel diameter. Four observers from two centers provided time-resolved and static delineations. Bland-Altman analysis was used to determine agreement between both observers and methods. RESULTS: DAo flow was 726 (348-1130) ml/min and umbilical vein flow 366 (150-782) ml/min by DUS gating. Bias±SD for DUS-gating versus MOG were - 45 ± 122 ml/min (-6 ± 15%) for DAo and 19 ± 136 ml/min (2 ± 24%) for umbilical vein flow. Repeated flow measurements in the same fetus showed similar volumes (median CoV = 11% (DAo) and 23% (umbilical vein)). Region of interest 50-150% of vessel diameter yielded flow 35-120%. Bias±SD for time-resolved versus static DUS-gated flow was 33 ± 39 ml/min (4 ± 6%) for DAo and 11 ± 84 ml/min (2 ± 15%) for umbilical vein flow. CONCLUSIONS: Quantification of blood flow in the fetal DAo and umbilical vein using DUS-gated phase-contrast CMR is feasible and agrees with the current reference method. Repeatability was generally high for CMR fetal blood flow assessment. An ROI similar to the vessel area or slightly larger is recommended. A static ROI is sufficient for fetal flow quantification using currently available CMR sequences.


Assuntos
Aorta Torácica/diagnóstico por imagem , Imageamento por Ressonância Magnética , Ultrassonografia Doppler , Ultrassonografia Pré-Natal , Veias Umbilicais/diagnóstico por imagem , Adulto , Aorta Torácica/fisiologia , Velocidade do Fluxo Sanguíneo , Feminino , Idade Gestacional , Humanos , Variações Dependentes do Observador , Ontário , Valor Preditivo dos Testes , Gravidez , Fluxo Sanguíneo Regional , Reprodutibilidade dos Testes , Suécia , Veias Umbilicais/fisiologia
17.
Am J Physiol Heart Circ Physiol ; 315(6): H1691-H1702, 2018 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-30265559

RESUMO

Intracardiac hemodynamic forces have been proposed to influence remodeling and be a marker of ventricular dysfunction. We aimed to quantify the hemodynamic forces in patients with repaired tetralogy of Fallot (rToF) to further understand the pathophysiological mechanisms as this could be a potential marker for pulmonary valve replacement (PVR) in these patients. Patients with rToF and pulmonary regurgitation (PR) > 20% ( n = 18) and healthy control subjects ( n = 15) underwent MRI, including four-dimensional flow. A subset of patients ( n = 8) underwent PVR and MRI after surgery. Time-resolved hemodynamic forces were quantified using 4D-flow data and indexed to ventricular volume. Patients had higher systolic and diastolic left ventricular (LV) hemodynamic forces compared with control subjects in the lateral-septal/LV outflow tract ( P = 0.011 and P = 0.0031) and inferior-anterior ( P < 0.0001 and P < 0.0001) directions, which are forces not aligned with blood flow. Forces did not change after PVR. Patients had higher RV diastolic forces compared with control subjects in the diaphragm-right ventricular (RV) outflow tract (RVOT; P < 0.001) and apical-basal ( P = 0.0017) directions. After PVR, RV systolic forces in the diaphragm-RVOT direction decreased ( P = 0.039) to lower levels than in control subjects ( P = 0.0064). RV diastolic forces decreased in all directions ( P = 0.0078, P = 0.0078, and P = 0.039) but were still higher than in control subjects in the diaphragm-RVOT direction ( P = 0.046). In conclusion, patients with rToF and PR had LV hemodynamic forces less aligned with intraventricular blood flow compared with control subjects and higher diastolic RV forces along the regurgitant flow direction in the RVOT and that of tricuspid inflow. Remaining force differences in the LV and RV after PVR suggest that biventricular pumping does not normalize after surgery. NEW & NOTEWORTHY Biventricular hemodynamic forces in patients with repaired tetralogy of Fallot and pulmonary regurgitation were quantified for the first time. Left ventricular hemodynamic forces were less aligned to the main blood flow direction in patients compared with control subjects. Higher right ventricular forces were seen along the pulmonary regurgitant and tricuspid inflow directions. Differences in forces versus control subjects remain after pulmonary valve replacement, suggesting that altered biventricular pumping does not normalize after surgery.


Assuntos
Hemodinâmica , Complicações Pós-Operatórias/fisiopatologia , Insuficiência da Valva Pulmonar/fisiopatologia , Tetralogia de Fallot/fisiopatologia , Disfunção Ventricular/fisiopatologia , Adulto , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Feminino , Humanos , Masculino , Complicações Pós-Operatórias/diagnóstico por imagem , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/etiologia , Tetralogia de Fallot/diagnóstico por imagem , Tetralogia de Fallot/cirurgia , Disfunção Ventricular/diagnóstico por imagem , Disfunção Ventricular/etiologia
18.
J Cardiovasc Magn Reson ; 20(1): 17, 2018 03 12.
Artigo em Inglês | MEDLINE | ID: mdl-29530064

RESUMO

BACKGROUND: Fetal cardiovascular magnetic resonance (CMR) imaging may provide a valuable adjunct to fetal echocardiography in the evaluation of congenital cardiovascular pathologies. However, dynamic fetal CMR is difficult due to the lack of direct in-utero cardiac gating. The aim of this study was to investigate the effectiveness of a newly developed Doppler ultrasound (DUS) device in humans for fetal CMR gating. METHODS: Fifteen fetuses (gestational age 30-39 weeks) were examined using 1.5 T CMR scanners at three different imaging sites. A newly developed CMR-compatible DUS device was used to generate gating signals from fetal cardiac motion. Gated dynamic balanced steady-state free precession images were acquired in 4-chamber and short-axis cardiac views. Gating signals during data acquisition were analyzed with respect to trigger variability and sensitivity. Image quality was assessed by measuring endocardial blurring (EB) and by image evaluation using a 4-point scale. Left ventricular (LV) volumetry was performed using the single-plane ellipsoid model. RESULTS: Gating signals from the fetal heart were detected with a variability of 26 ± 22 ms and a sensitivity of trigger detection of 96 ± 4%. EB was 2.9 ± 0.6 pixels (4-chamber) and 2.5 ± 0.1 pixels (short axis). Image quality scores were 3.6 ± 0.6 (overall), 3.4 ± 0.7 (mitral valve), 3.4 ± 0.7 (foramen ovale), 3.6 ± 0.7 (atrial septum), 3.7 ± 0.5 (papillary muscles), 3.8 ± 0.4 (differentiation myocardium/lumen), 3.7 ± 0.5 (differentiation myocardium/lung), and 3.9 ± 0.4 (systolic myocardial thickening). Inter-observer agreement for the scores was moderate to very good (kappa 0.57-0.84) for all structures. LV volumetry revealed mean values of 2.8 ± 1.2 ml (end-diastolic volume), 0.9 ± 0.4 ml (end systolic volume), 1.9 ± 0.8 ml (stroke volume), and 69.1 ± 8.4% (ejection fraction). CONCLUSION: High-quality dynamic fetal CMR was successfully performed using a newly developed DUS device for direct fetal cardiac gating. This technique has the potential to improve the utility of fetal CMR in the evaluation of congenital pathologies.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca , Ecocardiografia Doppler , Coração Fetal/diagnóstico por imagem , Cardiopatias Congênitas/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética , Ultrassonografia Pré-Natal/métodos , Boston , Técnicas de Imagem de Sincronização Cardíaca/instrumentação , Ecocardiografia Doppler/instrumentação , Desenho de Equipamento , Coração Fetal/fisiopatologia , Alemanha , Idade Gestacional , Cardiopatias Congênitas/embriologia , Cardiopatias Congênitas/fisiopatologia , Frequência Cardíaca Fetal , Humanos , Imagem Cinética por Ressonância Magnética/instrumentação , Valor Preditivo dos Testes , Volume Sistólico , Suécia , Transdutores , Ultrassonografia Pré-Natal/instrumentação , Função Ventricular Esquerda
19.
J Magn Reson Imaging ; 46(1): 207-217, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28152243

RESUMO

PURPOSE: To develop and assess a technique for self-gated fetal cardiac cine magnetic resonance imaging (MRI) using tiny golden angle radial sampling combined with iGRASP (iterative Golden-angle RAdial Sparse Parallel) for accelerated acquisition based on parallel imaging and compressed sensing. MATERIALS AND METHODS: Fetal cardiac data were acquired from five volunteers in gestational week 29-37 at 1.5T using tiny golden angles for eddy currents reduction. The acquired multicoil radial projections were input to a principal component analysis-based compression stage. The cardiac self-gating (CSG) signal for cardiac gating was extracted from the acquired radial projections and the iGRASP reconstruction procedure was applied. In all acquisitions, a total of 4000 radial spokes were acquired within a breath-hold of less than 15 seconds using a balanced steady-state free precession pulse sequence. The images were qualitatively compared by two independent observers (on a scale of 1-4) to a single midventricular cine image from metric optimized gating (MOG) and real-time acquisitions. RESULTS: For iGRASP and MOG images, good overall image quality (2.8 ± 0.4 and 2.6 ± 1.3, respectively, for observer 1; 3.6 ± 0.5 and 3.4 ± 0.9, respectively, for observer 2) and cardiac diagnostic quality (3.8 ± 0.4 and 3.4 ± 0.9, respectively, for observer 1; 3.6 ± 0.5 and 3.6 ± 0.9, respectively, for observer 2) were obtained, with visualized myocardial thickening over the cardiac cycle and well-defined myocardial borders to ventricular lumen and liver/lung tissue. For iGRASP, MOG, and real time, left ventricular lumen diameter (14.1 ± 2.2 mm, 14.2 ± 1.9 mm, 14.7 ± 1.1 mm, respectively) and wall thickness (2.7 ± 0.3 mm, 2.6 ± 0.3 mm, 3.0 ± 0.4, respectively) showed agreement and no statistically significant difference was found (all P > 0.05). Images with iGRASP tended to have higher overall image quality scores compared with MOG and particularly real-time images, albeit not statistically significant in this feasibility study (P > 0.99 and P = 0.12, respectively). CONCLUSION: Fetal cardiac cine MRI can be performed with iGRASP using tiny golden angles and CSG. Comparison with other fetal cardiac cine MRI methods showed that the proposed method produces high-quality fetal cardiac reconstructions. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 1 J. MAGN. RESON. IMAGING 2017;46:207-217.


Assuntos
Técnicas de Imagem Cardíaca/métodos , Técnicas de Imagem de Sincronização Cardíaca/métodos , Coração Fetal/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Imagem Cinética por Ressonância Magnética/métodos , Diagnóstico Pré-Natal/métodos , Processamento de Sinais Assistido por Computador , Adulto , Algoritmos , Compressão de Dados , Estudos de Viabilidade , Feminino , Humanos , Masculino , Gravidez , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa