J Appl Clin Med Phys ; 17(2): 74-84, 2016 03 08.
Artigo em Inglês | MEDLINE | ID: mdl-27074474

RESUMO

Tracking accuracy for the CyberKnife's Synchrony system is commonly evaluated using a film-based verification method. We have evaluated a verification system that uses a webcam and a printed calibrated grid to verify tracking accuracy over three different motion patterns. A box with an attached printed calibrated grid and four fiducial markers was attached to the motion phantom. A target marker was positioned at the grid's center. The box was set up using the other three markers. Target tracking accuracy was evaluated under three conditions: 1) stationary; 2) sinusoidal motion with different amplitudes of 5, 10, 15, and 20 mm for the same cycle of 4 s and different cycles of 2, 4, 6, and 8 s with the same amplitude of 15 mm; and 3) irregular breathing patterns in six human volunteers breathing normally. Infrared markers were placed on the volunteers' abdomens, and their trajectories were used to simulate the target motion. All tests were performed with one-dimensional motion in craniocaudal direction. The webcam captured the grid's motion and a laser beam was used to simulate the CyberKnife's beam. Tracking error was defined as the difference between the grid's center and the laser beam. With a stationary target, mean tracking error was measured at 0.4 mm. For sinusoidal motion, tracking error was less than 2 mm for any amplitude and breathing cycle. For the volunteers' breathing patterns, the mean tracking error range was 0.78-1.67 mm. Therefore, accurate lesion targeting requires individual quality assurance for each patient.


Assuntos
Algoritmos , Calibragem , Neoplasias/cirurgia , Imagens de Fantasmas , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Cirurgia Assistida por Computador/métodos , Marcadores Fiduciais , Humanos , Pulmão/fisiopatologia , Pulmão/efeitos da radiação , Movimento , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada , Respiração , Gravação em Vídeo
2.
Br J Radiol ; 92(1100): 20190004, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31188018

RESUMO

OBJECTIVE: To evaluate and compare the dosimetric plan quality for noncoplanar volumetric arc therapy of single and multiple brain metastases using the linear accelerator-based radiosurgery system HyperArc and a robotic radiosurgery system. METHODS: 31 tumors from 24 patients were treated by stereotactic radiosurgery using the CyberKnife system. CT images, structure sets, and dose files were transferred to the Eclipse treatment planning system for the HyperArc system. Dosimetric parameters for both plans were compared. The beam-on time was calculated from the total monitor unit and dose rate. RESULTS: For normal brain tissue, the received volume doses were significantly lower for HyperArc than for CyberKnife_G4 and strongly correlated with the planning target volume (PTV) for cases of single brain metastasis. In addition, the difference in volume dose between CyberKnife_G4 and HyperArc was proportional to the PTV. For multiple brain metastases, no significant difference was observed between the two stereotactic radiosurgery systems, except for high-dose region in the normal tissue. In low dose for brain minus PTV, when the maximum distance among each target was above 8.0 cm, HyperArc delivered higher dose than CyberKnife_G4. The mean ± SDs for the beam-on time were 15.8 ± 5.3 and 5.6 ± 0.8 min for CyberKnife_G4 and HyperArc, respectively (p < .01). CONCLUSION: HyperArc is best suited for larger targets in single brain metastasis and for smaller inter tumor tumor distances in multiple brain metastases. ADVANCES IN KNOWLEDGE: The performance of HyperArc in comparison with CyberKnife_G4 was depended on defined margin and tumor distances.


Assuntos
Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/secundário , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Encéfalo/efeitos da radiação , Encéfalo/cirurgia , Feminino , Humanos , Masculino , Radiometria , Dosagem Radioterapêutica , Resultado do Tratamento
3.
Med Phys ; 46(9): 3757-3766, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30943311

RESUMO

PURPOSE: The SynchronyTM Respiratory Tracking System (SRTS) component of the CyberKnife® Robotic Radiosurgery System (Accuray, Inc., Sunnyvale CA) enables real-time tracking of moving targets by modeling the correlation between the targets and external surrogate light-emitting diode (LED) markers placed on the patient's chest. Previous studies reported some cases with respiratory phase shifts between lung tumor and chest wall motions. In this study, the impacts of respiratory phase shifts on the motion-tracking accuracy of the SRTS were investigated. METHODS: A plastic scintillator was used to detect the position of the x-ray beams. The scintillation light was recorded using a camera in a dark room. A moving phantom moved a U-shaped frame on the scintillator with a 4th power of sinusoidal functions. Three metallic markers for motion tracking and four fluorescent tapes were attached to the frame. The fluorescent tapes were used to identify phantom position and respiratory phase for each video frame. The beam positions collected, when considered relative to the phantom motion, represent the degree of tracking error. Beam position was calculated by adding error value to phantom position. Motions with respiratory phase shifts between the target and an extra stage mimicking chest wall motion were also tested for LED markers. Log files of the SRTS were analyzed to evaluate correlation errors. RESULTS: When target and LED marker motions were synchronized with a respiratory cycle of 4 s, the maximum tracking errors for 90% and 95% of beam-on time were 1.0 mm and 1.2 mm, respectively. The frequency of tracking errors increased when LED marker motion phase preceded target motion. Tracking errors that corresponded to 90% beam-on time were within 2.4 mm for 5-15% of phase shifts. In contrast, the tracking errors were very large when the LED marker delayed to the target motions; the maximum errors of 90% beam-on time were 3.0, 3.8, and 7.5 mm for 5%, 10%, and 15% of phase shifts, respectively. The patterns of the tracking errors derived from the scintillation light were very similar to those of the correlation data of the SRTS derived from the log files, indicating that the tracking errors caused mainly due to the errors in modeling the correlation data. With long respiratory cycle of 6 s, the tracking errors were significantly decreased; the maximum tracking errors for 95% beam-on time were 1.6 mm and 2.2 mm for early and delayed LED motion. CONCLUSION: We have investigated the motion-tracking accuracy of the CyberKnife SRTS for cases with the respiratory phase shift between the target and the LED marker. The maximum tracking errors for 90% probability were within 2.4 mm when the target delays to the LED markers. When LED marker delays, however, very large tracking errors were observed. With a long respiratory cycle, the tracking errors were greatly improved to less than 2.2 mm. Coaching slow breathing will be useful for accurate motion tracking radiotherapy.


Assuntos
Movimento , Radiocirurgia/métodos , Respiração , Imagens de Fantasmas , Planejamento da Radioterapia Assistida por Computador
4.
Med Phys ; 2018 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-29858498

RESUMO

PURPOSE: The Synchrony™ Respiratory Tracking System of the CyberKnife® Robotic Radiosurgery System (Accuray, Inc., Sunnyvale, CA, USA) enables real-time tracking of moving targets such as lung and liver tumors during radiotherapy. Although film measurements have been used for quality assurance of the tracking system, they cannot evaluate the temporal tracking accuracy. We have developed a verification system using a plastic scintillator that can evaluate the temporal accuracy of the CyberKnife Synchrony. METHODS: A phantom consisting of a U-shaped plastic frame with three fiducial markers was used. The phantom was moved on a plastic scintillator plate. To identify the phantom position on the recording video in darkness, four pieces of fluorescent tape representing the corners of a 10 cm × 10 cm square around an 8 cm × 8 cm window were attached to the phantom. For a stable respiration model, the phantom was moved with the fourth power of a sinusoidal wave with breathing cycles of 4, 3, and 2 s and an amplitude of 1 cm. To simulate irregular breathing, the respiratory cycle was varied with Gaussian random numbers. A virtual target was generated at the center of the fluorescent markers using the MultiPlan™ treatment planning system. Photon beams were irradiated using a fiducial tracking technique. In a dark room, the fluorescent light of the markers and the scintillation light of the beam position were recorded using a camera. For each video frame, a homography matrix was calculated from the four fluorescent marker positions, and the beam position derived from the scintillation light was corrected. To correct the displacement of the beam position due to oblique irradiation angles and other systematic measurement errors, offset values were derived from measurements with the phantom held stationary. RESULTS: The average SDs of beam position measured without phantom motion were 0.16 and 0.20 mm for lateral and longitudinal directions, respectively. For the stable respiration model, the tracking errors (mean ± SD) were 0.40 ± 0.64 mm, -0.07 ± 0.79 mm, and 0.45 ± 1.14 mm for breathing cycles of 4, 3, and 2 s, respectively. The tracking errors showed significant linear correlation with the phantom velocity. The correlation coefficients were 0.897, 0.913, and 0.957 for breathing cycles of 4, 3, and 2 s, respectively. The unstable respiration model also showed linear correlation between tracking errors and phantom velocity. The probability of tracking error incidents increased with decreasing length of the respiratory cycles. Although the tracking error incidents increased with larger variations in respiratory cycle, the effect on the cumulative probability was insignificant. For a respiratory cycle of 4 s, the maximum tracking error was 1.10 and 1.43 mm at the probability of 10% and 5%, respectively. Large tracking errors were observed when there was phase shift between the tumor and the LED marker. CONCLUSION: This technique allows evaluation of the motion tracking accuracy of the Synchrony™ system over time by measurement of the photon beam. The velocity of the target and phase shift have significant effects on accuracy.