Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
1.
Phys Rev Lett ; 130(14): 143001, 2023 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-37084433

RESUMO

Using cavity ring-down spectroscopy to probe R-branch transitions of CO in N_{2}, we show that the spectral core of the line shapes associated with the first few rotational quantum numbers, J, can be accurately modeled using a sophisticated line profile, provided that a pressure-dependent line area is introduced. This correction vanishes as J increases and is always negligible in CO-He mixtures. The results are supported by molecular dynamics simulations attributing the effect to non-Markovian behavior of collisions at short times. This work has large implications because corrections must be considered for accurate determinations of integrated line intensities, and for spectroscopic databases and radiative transfer codes used for climate predictions and remote sensing.

2.
Faraday Discuss ; 245(0): 368-379, 2023 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-37306220

RESUMO

We report direct frequency comb spectroscopy of the 2ν1 band of H13CN in the short-wave infrared (λ = 1.56 µm) towards experimental validation of molecular line lists that support observatories like JWST. The laboratory measurements aim to test spectral reference data generated from an experimentally accurate potential energy surface (PES) and an ab initio dipole moment surface (DMS) calculated from quantum chemistry theory. Benchmarking theory with experiment will improve confidence in new astrophysics and astrochemistry inferred from spectroscopic observations of HCN and HNC. Here we describe our instrumentation and initial results using a cross-dispersed spectrometer with a virtually imaged phased array (VIPA).

3.
Anal Chem ; 94(45): 15818-15826, 2022 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-36326823

RESUMO

We present a primary method for absolute reference material-free measurement of gaseous elemental mercury mass concentration based on laser absorption spectroscopy at wavelengths near 254 nm and anchored to the international system of units. A 76 m-long multipass cell provides a detection limit of 1 ng m-3 for an averaging time of 8 min. A dual-cell arrangement, comprising a single-pass and a multipass cell, provides a dynamic range of six decades and spans from ambient to emission levels of gaseous elemental mercury (1 ng m-3 to 1000 µg m-3). The relative standard uncertainty of the measurement is 0.5% in the 0.25 to 1000 µg m-3 range.


Assuntos
Poluentes Atmosféricos , Mercúrio , Mercúrio/análise , Poluentes Atmosféricos/análise , Análise Espectral , Monitoramento Ambiental/métodos
4.
Phys Rev Lett ; 129(4): 043002, 2022 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-35939021

RESUMO

Intensities of lines in the near-infrared second overtone band (3-0) of ^{12}C^{16}O are measured and calculated to an unprecedented degree of precision and accuracy. Agreement between theory and experiment to better than 1‰ is demonstrated by results from two laboratories involving two independent absorption- and dispersion-based cavity-enhanced techniques. Similarly, independent Fourier transform spectroscopy measurements of stronger lines in this band yield mutual agreement and consistency with theory at the 1‰ level. This set of highly accurate intensities can provide an intrinsic reference for reducing biases in future measurements of spectroscopic peak areas.


Assuntos
Espectroscopia de Infravermelho com Transformada de Fourier
5.
Artigo em Inglês | MEDLINE | ID: mdl-37461431

RESUMO

Although the Voigt profile has long been used to analyze absorption spectra, the quest for increased precision, accuracy and generality drives the application of advanced models of atomic and molecular line shapes. To this end, the Hartmann-Tran profile is now recommended as a standard for high-resolution spectroscopy because it parameterizes relevant higher-order physical effects, is computationally efficient, and reduces to other widely used profiles as limiting cases. This work explores the uncertainty with which line shape parameters can be obtained from constrained multi-spectrum fits of spectra simulated with this standard profile, varying uncertainty levels in the spectrum detuning and absorption axes, and spanning a range of sampling density, pressure, and line shape parameter values. The analysis focuses on how noise-limited measurement precision of frequency detuning and absorption drive statistical uncertainties in fitted parameters and numerical correlations between these quantities. Also, we quantify the degree of equivalence between the full Hartmann-Tran profile and those derived from it in terms of fitted peak areas and line shape parameters. Finally, we introduce a new open-source software package named Multi-spectrum Analysis Tool for Spectroscopy (MATS), which allows users to fit the HTP and its derived profiles to experimental or simulated absorption spectra to explore the limits of the HTP under actual experimental or user-defined conditions.

6.
Anal Chem ; 93(2): 1050-1058, 2021 01 19.
Artigo em Inglês | MEDLINE | ID: mdl-33302624

RESUMO

We present a direct comparison between two independent methods for the measurement of gaseous elemental mercury (GEM) mass concentration: isotope dilution cold-vapor inductively coupled plasma mass spectrometry (ID-CV-ICP-MS) and laser absorption spectroscopy (LAS). The former technique combined with passive sorbent tube sampling is currently the primary method at NIST for mercury gas standards traceability to the International System of Units (SI). This traceability is achieved via measurements on a mercury-containing reference material. The latter technique has been recently developed at NIST and involves real-time measurements of light attenuation caused by GEM, with SI traceability based in part on the known spontaneous emission lifetime of the probed 6 1S0-6 3P1 intercombination transition of elemental mercury (Hg0). Using a steady-flow Hg0-in-air generator to produce samples measured by both methods, we use LAS to measure the sample gas and in parallel we collect the Hg0 on sorbent tubes to be subsequently analyzed using ID-CV-ICP-MS. Over the examined mass concentration range (41 µg/m3 to 287 µg/m3 Hg0 in air), the relative disagreement between the two approaches ranged from (1.0 to 1.8)%. The relative combined standard uncertainty on average is 0.4% and 0.9%, for the LAS and MS methods, respectively. Our comparison studies help validate the accuracy of the ID-CV-ICP-MS primary method as well as establish the LAS technique as an attractive alternative primary method for SI-traceable measurements of GEM.


Assuntos
Lasers , Mercúrio/análise , Gases/análise , Espectrometria de Massas , Análise Espectral
7.
Opt Lett ; 46(13): 3057-3060, 2021 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-34197378

RESUMO

Frequency-stabilized mid-infrared lasers are valuable tools for precision molecular spectroscopy. However, their implementation remains limited by complicated stabilization schemes. Here we achieve optical self-locking of a quantum cascade laser to the resonant leak-out field of a highly mode-matched two-mirror cavity. The result is a simple approach to achieving stable frequencies from high-powered mid-infrared lasers. For short time scales (<0.1ms), we report a linewidth reduction factor of 3×10-6 to a linewidth of 12 Hz. Furthermore, we demonstrate two-photon cavity-enhanced absorption spectroscopy of an N2O overtone transition near a wavelength of 4.53 µm.

8.
Artigo em Inglês | MEDLINE | ID: mdl-36452911

RESUMO

Using frequency-agile rapid scanning cavity ring-down spectroscopy, we measured line intensities and line shape parameters of 14N2 16O in air in the (4200)←(0000) and (5000)←(0000) bands near 1.6 µm. The absorption spectra were modeled with multi-spectrum fits of Voigt and speed-dependent Voigt profiles. The measured line intensities and air-broadening parameters exhibit deviations of several percent relative to values provided in HITRAN 2016. Our measured intensities for these two bands have relative combined standard uncertainties of ∼1% which is approximately five times smaller than literature values. Comparison of the present air-broadening and speed-dependent broadening parameters to experimental literature values for other rotation-vibration bands of N2O indicates significant differences in magnitude and J-dependence. For applications requiring high spectral fidelity, these results suggest that the assumption of band-independent line shape parameters is not appropriate.

9.
Artigo em Inglês | MEDLINE | ID: mdl-38516121

RESUMO

We measured air broadening in the (30012) ← (00001) carbon dioxide (CO2) band up to J″=50 using frequency-agile rapid scanning cavity ring-down spectroscopy. By using synthetic air samples with varying levels of nitrogen, oxygen, and argon, multi-spectrum fitting allowed for the collisional broadening terms of each major air component to be simultaneously determined in addition to advanced line shape parameters at atmospherically relevant CO2 mixing ratios. These values were compared to broadener-specific line shape parameters from the literature. Fits to measured spectra were also constrained with results from requantized classical molecular dynamic simulations. We show that this approach enables differentiation between narrowing mechanisms in advanced line shape parameters retrieved from experimental spectra of limited signal-to-noise ratio.

10.
Artigo em Inglês | MEDLINE | ID: mdl-37554518

RESUMO

This paper outlines the major updates of the line-shape parameters that were performed for the nitrous oxide (N2O) and carbon monoxide (CO) molecules listed in the HITRAN2020 database. We reviewed the collected measurements for the air- and self-broadened N2O and CO spectra to determine proper values for the spectroscopic parameters. Careful comparisons of broadening parameters using the Voigt and speed-dependent Voigt line-shape profiles were performed among various published results for both N2O and CO. Selected data allowed for developing semi-empirical models, which were used to extrapolate/interpolate existing data to update broadening parameters of all the lines of these molecules in the HITRAN database. In addition to the line broadening parameters (and their temperature dependences), the pressure shift values were revised for N2O and CO broadened by air and self for all the bands. The air and self speed-dependence of the broadening parameter for these two molecules were added for every transition as well. Furthermore, we determined the first-order line-mixing parameters using the Exponential Power Gap (EPG) scaling law. These new parameters are now available at HITRAN online.

11.
Artigo em Inglês | MEDLINE | ID: mdl-33100382

RESUMO

The λ = 2.06 µm absorption band of CO2 is widely used for the remote sensing of atmospheric carbon dioxide, making it relevant to many important top-down measurements of carbon flux. The forward models used in the retrieval algorithms employed in these measurements require increasingly accurate line intensity and line shape data from which absorption cross-sections can be computed. To overcome accuracy limitations of existing line lists, we used frequency-stabilized cavity ring-down spectroscopy to measure 39 transitions in the 12C16O2 absorption band. The line intensities were measured with an estimated relative combined standard uncertainty of u r = 0.08 %. We predicted the J-dependence of the measured intensities using two theoretical models: a one-dimensional spectroscopic model with Herman-Wallis rotation-vibration corrections, and a line-by-line ab initio dipole moment surface model [Zak et al. JQSRT 2016;177:31-42]. For the second approach, we fit only a single factor to rescale the theoretical integrated band intensity to be consistent with the measured intensities. We find that the latter approach yields an equally adequate representation of the fitted J-dependent intensity data and provides the most physically general representation of the results. Our recommended value for the integrated band intensity equal to 7.183 × 10-21 cm molecule-1 ± 6 × 10-24 cm molecule-1 is based on the rescaled ab initio model and corresponds to a fitted scale factor of 1.0069 ± 0.0002. Comparisons of literature intensity values to our results reveal systematic deviations ranging from -1.16 % to +0.33 %.

12.
Phys Rev Lett ; 123(4): 043001, 2019 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-31491247

RESUMO

To accurately attribute sources and sinks of molecules like CO_{2}, remote sensing missions require line intensities (S) with relative uncertainties u_{r}(S)<0.1%. However, discrepancies in S of ≈1% are common when comparing different experiments, thus limiting their potential impact. Here we report a cavity ring-down spectroscopy multi-instrument comparison which revealed that the hardware used to digitize analog ring-down signals caused variability in spectral integrals which yield S. Our refined approach improved measurement accuracy 25-fold, resulting in u_{r}(S)=0.06%.

13.
Anal Chem ; 90(11): 6781-6788, 2018 06 05.
Artigo em Inglês | MEDLINE | ID: mdl-29708730

RESUMO

Isotope dilution-cold-vapor-inductively coupled plasma mass spectrometry (ID-CV-ICPMS) has become the primary standard for measurement of gaseous elemental mercury (GEM) mass concentration. However, quantitative mass spectrometry is challenging for several reasons including (1) the need for isotopic spiking with a standard reference material, (2) the requirement for bias-free passive sampling protocols, (3) the need for stable mass spectrometry interface design, and (4) the time and cost involved for gas sampling, sample processing, and instrument calibration. Here, we introduce a high-resolution laser absorption spectroscopy method that eliminates the need for sample-specific calibration standards or detailed analysis of sample treatment losses. This technique involves a tunable, single-frequency laser absorption spectrometer that measures isotopically resolved spectra of elemental mercury (Hg) spectra of 6 1S0 ← 6 3P1 intercombination transition near λ = 253.7 nm. Measured spectra are accurately modeled from first-principles using the Beer-Lambert law and Voigt line profiles combined with literature values for line positions, line shape parameters, and the spontaneous emission Einstein coefficient to obtain GEM mass concentration values. We present application of this method for the measurement of the equilibrium concentration of mercury vapor near room temperature. Three closed systems are considered: two-phase mixtures of liquid Hg and its vapor and binary two-phase mixtures of Hg-air and Hg-N2 near atmospheric pressure. Within the experimental relative standard uncertainty, 0.9-1.5% congruent values of the equilibrium Hg vapor concentration are obtained for the Hg-only, Hg-air, Hg-N2 systems, in confirmation with thermodynamic predictions. We also discuss detection limits and the potential of the present technique to serve as an absolute primary standard for measurements of gas-phase mercury concentration and isotopic composition.


Assuntos
Lasers , Mercúrio/análise , Ar/análise , Espectrometria de Massas , Nitrogênio/química
14.
Anal Chem ; 90(7): 4711-4718, 2018 04 03.
Artigo em Inglês | MEDLINE | ID: mdl-29498261

RESUMO

There are many gas phase compounds present in the atmosphere that affect and influence the earth's climate. These compounds absorb and emit radiation, a process which is the fundamental cause of the greenhouse effect. The major greenhouse gases in the earth's atmosphere are carbon dioxide, methane, nitrous oxide, and ozone. Some halocarbons are also strong greenhouse gases and are linked to stratospheric ozone depletion. Hydrocarbons and monoterpenes are precursors and contributors to atmospheric photochemical processes, which lead to the formation of particulates and secondary photo-oxidants such as ozone, leading to photochemical smog. Reactive gases such as nitric oxide and sulfur dioxide are also compounds found in the atmosphere and generally lead to the formation of other oxides. These compounds can be oxidized in the air to acidic and corrosive gases and contribute to photochemical smog. Measurements of these compounds in the atmosphere have been ongoing for decades to track growth rates and assist in curbing emissions of these compounds into the atmosphere. To accurately establish mole fraction trends and assess the role of these gas phase compounds in atmospheric chemistry, it is essential to have good calibration standards. The National Institute of Standards and Technology has been developing standards of many of these compounds for over 40 years. This paper discusses the development of these standards.

15.
Anal Bioanal Chem ; 410(24): 6247-6255, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29980807

RESUMO

The noble gases, namely neon, argon, krypton and xenon, have many uses including in incandescent and gas discharge lighting, in plasma televisions, shielding gas in welding, in lasers for surgery and semiconductors, and in magnetic resonance imaging (MRI) of the lungs. When incorporating these noble gases in industries, especially the medical field, it is important to know accurately the composition of the noble gas mixture. Therefore, there is a need for accurate gas standards that can be used to determine the noble gas amount-of-substance fraction in the appropriate mixture application. A recent comparison of mixtures containing four noble gases in a helium balance showed mixed results among National Metrology Institutes. Significant differences, 0.7 to 3.8% relative, were seen in the analytical amount-of-substance assignments versus the gravimetric value of the noble gases in the comparison mixture when using "binary standards", i.e. neon in helium, argon in helium and krypton in helium, as applied by the National Institute of Standards and Technology. Post-comparison studies showed that when all four noble gases were included in the standards, the agreement between analytical and gravimetric values was within 0.05% relative. Further research revealed that different carrier gases (hydrogen, helium and nitrogen) resulted in varying differences between the analytical and gravimetric values assignments. This paper will discuss the findings of these analytical comparisons. Graphical abstract ᅟ.

16.
J Quant Spectrosc Radiat Transf ; 206: 367-377, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29731521

RESUMO

Reported here are highly accurate, experimentally measured ro-vibrational transition intensities for the R-branch of the (20012) - (00001) 12C16O2 band near λ = 2 µm. Measurements were performed by a frequency-stabilized cavity ring-down spectroscopy (FS-CRDS) instrument designed to achieve precision molecular spectroscopy in this important region of the infrared. Through careful control and traceable characterization of CO2 sample conditions, and through high-fidelity measurements spanning several months in time, we achieve relative standard uncertainties for the reported transition intensities between 0.15 % and 0.46 %. Such high accuracy spectroscopy is shown to provide a stringent test of calculated potential energy and ab initio dipole moment surfaces, and therefore transition intensities calculated from first principles.

17.
J Quant Spectrosc Radiat Transf ; 186: 118-138, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27840454

RESUMO

Retrievals of atmospheric composition from near-infrared measurements require measurements of airmass to better than the desired precision of the composition. The oxygen bands are obvious choices to quantify airmass since the mixing ratio of oxygen is fixed over the full range of atmospheric conditions. The OCO-2 mission is currently retrieving carbon dioxide concentration using the oxygen A-band for airmass normalization. The 0.25% accuracy desired for the carbon dioxide concentration has pushed the required state-of-the-art for oxygen spectroscopy. To measure O2 A-band cross-sections with such accuracy through the full range of atmospheric pressure requires a sophisticated line-shape model (Rautian or Speed-Dependent Voigt) with line mixing (LM) and collision induced absorption (CIA). Models of each of these phenomena exist, however, this work presents an integrated self-consistent model developed to ensure the best accuracy. It is also important to consider multiple sources of spectroscopic data for such a study in order to improve the dynamic range of the model and to minimize effects of instrumentation and associated systematic errors. The techniques of Fourier Transform Spectroscopy (FTS) and Cavity Ring-Down Spectroscopy (CRDS) allow complimentary information for such an analysis. We utilize multispectrum fitting software to generate a comprehensive new database with improved accuracy based on these datasets. The extensive information will be made available as a multi-dimensional cross-section (ABSCO) table and the parameterization will be offered for inclusion in the HITRANonline database.

18.
Opt Express ; 24(10): 10424-34, 2016 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-27409866

RESUMO

Dual-comb spectroscopy allows for the rapid, multiplexed acquisition of high-resolution spectra without the need for moving parts or low-resolution dispersive optics. This method of broadband spectroscopy is most often accomplished via tight phase locking of two mode-locked lasers or via sophisticated signal processing algorithms, and therefore, long integration times of phase coherent signals are difficult to achieve. Here we demonstrate an alternative approach to dual-comb spectroscopy using two phase modulator combs originating from a single continuous-wave laser capable of > 2 hours of coherent real-time averaging. The dual combs were generated by driving the phase modulators with step-recovery diodes where each comb consisted of > 250 teeth with 203 MHz spacing and spanned > 50 GHz region in the near-infrared. The step-recovery diodes are passive devices that provide low-phase-noise harmonics for efficient coupling into an enhancement cavity at picowatt optical powers. With this approach, we demonstrate the sensitivity to simultaneously monitor ambient levels of CO2, CO, HDO, and H2O in a single spectral region at a maximum acquisition rate of 150 kHz. Robust, compact, low-cost and widely tunable dual-comb systems could enable a network of distributed multiplexed optical sensors.

19.
Opt Express ; 23(11): 14472-86, 2015 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-26072808

RESUMO

Recent developments in optical metrology have tremendously improved the precision and accuracy of the horizontal (frequency) axis in measured spectra. However, the vertical (typically absorbance) axis is usually based on intensity measurements that are subject to instrumental errors which limit the spectrum accuracy. Here we report a one-dimensional spectroscopy that uses only the measured frequencies of high-finesse cavity modes to provide complete information about the dispersive properties of the spectrum. Because this technique depends solely on the measurement of frequencies or their differences, it is insensitive to systematic errors in the detection of light intensity and has the potential to become the most accurate of all absorptive and dispersive spectroscopic methods. The experimental results are compared to measurements by two other high-precision cavity-enhanced spectroscopy methods. We expect that the proposed technique will have significant impact in fields such as fundamental physics, gas metrology and environmental remote sensing.

20.
Phys Rev Lett ; 114(24): 243001, 2015 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-26196972

RESUMO

Atmospheric CO(2) concentrations are being closely monitored by remote sensing experiments which rely on knowing line intensities with an uncertainty of 0.5% or better. Most available laboratory measurements have uncertainties much larger than this. We report a joint experimental and theoretical study providing rotation-vibration line intensities with the required accuracy. The ab initio calculations are extendible to all atmospherically important bands of CO(2) and to its isotologues. As such, they will form the basis for detailed CO(2) spectroscopic line lists for future studies.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa