Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 186
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Nature ; 629(8013): 810-818, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38778234

RESUMO

Accurate and continuous monitoring of cerebral blood flow is valuable for clinical neurocritical care and fundamental neurovascular research. Transcranial Doppler (TCD) ultrasonography is a widely used non-invasive method for evaluating cerebral blood flow1, but the conventional rigid design severely limits the measurement accuracy of the complex three-dimensional (3D) vascular networks and the practicality for prolonged recording2. Here we report a conformal ultrasound patch for hands-free volumetric imaging and continuous monitoring of cerebral blood flow. The 2 MHz ultrasound waves reduce the attenuation and phase aberration caused by the skull, and the copper mesh shielding layer provides conformal contact to the skin while improving the signal-to-noise ratio by 5 dB. Ultrafast ultrasound imaging based on diverging waves can accurately render the circle of Willis in 3D and minimize human errors during examinations. Focused ultrasound waves allow the recording of blood flow spectra at selected locations continuously. The high accuracy of the conformal ultrasound patch was confirmed in comparison with a conventional TCD probe on 36 participants, showing a mean difference and standard deviation of difference as -1.51 ± 4.34 cm s-1, -0.84 ± 3.06 cm s-1 and -0.50 ± 2.55 cm s-1 for peak systolic velocity, mean flow velocity, and end diastolic velocity, respectively. The measurement success rate was 70.6%, compared with 75.3% for a conventional TCD probe. Furthermore, we demonstrate continuous blood flow spectra during different interventions and identify cascades of intracranial B waves during drowsiness within 4 h of recording.


Assuntos
Velocidade do Fluxo Sanguíneo , Encéfalo , Circulação Cerebrovascular , Ultrassonografia , Humanos , Velocidade do Fluxo Sanguíneo/fisiologia , Encéfalo/irrigação sanguínea , Encéfalo/diagnóstico por imagem , Encéfalo/fisiologia , Circulação Cerebrovascular/fisiologia , Imageamento Tridimensional/instrumentação , Imageamento Tridimensional/métodos , Erros Médicos , Razão Sinal-Ruído , Pele , Crânio , Sonolência/fisiologia , Ultrassonografia/instrumentação , Ultrassonografia/métodos , Adulto
2.
Nature ; 613(7945): 667-675, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36697864

RESUMO

Continuous imaging of cardiac functions is highly desirable for the assessment of long-term cardiovascular health, detection of acute cardiac dysfunction and clinical management of critically ill or surgical patients1-4. However, conventional non-invasive approaches to image the cardiac function cannot provide continuous measurements owing to device bulkiness5-11, and existing wearable cardiac devices can only capture signals on the skin12-16. Here we report a wearable ultrasonic device for continuous, real-time and direct cardiac function assessment. We introduce innovations in device design and material fabrication that improve the mechanical coupling between the device and human skin, allowing the left ventricle to be examined from different views during motion. We also develop a deep learning model that automatically extracts the left ventricular volume from the continuous image recording, yielding waveforms of key cardiac performance indices such as stroke volume, cardiac output and ejection fraction. This technology enables dynamic wearable monitoring of cardiac performance with substantially improved accuracy in various environments.


Assuntos
Ecocardiografia , Desenho de Equipamento , Coração , Dispositivos Eletrônicos Vestíveis , Humanos , Débito Cardíaco , Ecocardiografia/instrumentação , Ecocardiografia/normas , Coração/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Volume Sistólico , Dispositivos Eletrônicos Vestíveis/normas , Pele
3.
Nature ; 608(7922): 317-323, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35948711

RESUMO

Compared with their three-dimensional (3D) counterparts, low-dimensional metal halide perovskites (2D and quasi-2D; B2An-1MnX3n+1, such as B = R-NH3+, A = HC(NH2)2+, Cs+; M = Pb2+, Sn2+; X = Cl-, Br-, I-) with periodic inorganic-organic structures have shown promising stability and hysteresis-free electrical performance1-6. However, their unique multiple-quantum-well structure limits the device efficiencies because of the grain boundaries and randomly oriented quantum wells in polycrystals7. In single crystals, the carrier transport through the thickness direction is hindered by the layered insulating organic spacers8. Furthermore, the strong quantum confinement from the organic spacers limits the generation and transport of free carriers9,10. Also, lead-free metal halide perovskites have been developed but their device performance is limited by their low crystallinity and structural instability11. Here we report a low-dimensional metal halide perovskite BA2MAn-1SnnI3n+1 (BA, butylammonium; MA, methylammonium; n = 1, 3, 5) superlattice by chemical epitaxy. The inorganic slabs are aligned vertical to the substrate and interconnected in a criss-cross 2D network parallel to the substrate, leading to efficient carrier transport in three dimensions. A lattice-mismatched substrate compresses the organic spacers, which weakens the quantum confinement. The performance of a superlattice solar cell has been certified under the quasi-steady state, showing a stable 12.36% photoelectric conversion efficiency. Moreover, an intraband exciton relaxation process may have yielded an unusually high open-circuit voltage (VOC).

4.
Nature ; 577(7789): 209-215, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31915395

RESUMO

Strain engineering is a powerful tool with which to enhance semiconductor device performance1,2. Halide perovskites have shown great promise in device applications owing to their remarkable electronic and optoelectronic properties3-5. Although applying strain to halide perovskites has been frequently attempted, including using hydrostatic pressurization6-8, electrostriction9, annealing10-12, van der Waals force13, thermal expansion mismatch14, and heat-induced substrate phase transition15, the controllable and device-compatible strain engineering of halide perovskites by chemical epitaxy remains a challenge, owing to the absence of suitable lattice-mismatched epitaxial substrates. Here we report the strained epitaxial growth of halide perovskite single-crystal thin films on lattice-mismatched halide perovskite substrates. We investigated strain engineering of α-formamidinium lead iodide (α-FAPbI3) using both experimental techniques and theoretical calculations. By tailoring the substrate composition-and therefore its lattice parameter-a compressive strain as high as 2.4 per cent is applied to the epitaxial α-FAPbI3 thin film. We demonstrate that this strain effectively changes the crystal structure, reduces the bandgap and increases the hole mobility of α-FAPbI3. Strained epitaxy is also shown to have a substantial stabilization effect on the α-FAPbI3 phase owing to the synergistic effects of epitaxial stabilization and strain neutralization. As an example, strain engineering is applied to enhance the performance of an α-FAPbI3-based photodetector.

5.
Nature ; 583(7818): 790-795, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32728239

RESUMO

Organic-inorganic hybrid perovskites have electronic and optoelectronic properties that make them appealing in many device applications1-4. Although many approaches focus on polycrystalline materials5-7, single-crystal hybrid perovskites show improved carrier transport and enhanced stability over their polycrystalline counterparts, due to their orientation-dependent transport behaviour8-10 and lower defect concentrations11,12. However, the fabrication of single-crystal hybrid perovskites, and controlling their morphology and composition, are challenging12. Here we report a solution-based lithography-assisted epitaxial-growth-and-transfer method for fabricating single-crystal hybrid perovskites on arbitrary substrates, with precise control of their thickness (from about 600 nanometres to about 100 micrometres), area (continuous thin films up to about 5.5 centimetres by 5.5 centimetres), and composition gradient in the thickness direction (for example, from methylammonium lead iodide, MAPbI3, to MAPb0.5Sn0.5I3). The transferred single-crystal hybrid perovskites are of comparable quality to those directly grown on epitaxial substrates, and are mechanically flexible depending on the thickness. Lead-tin gradient alloying allows the formation of a graded electronic bandgap, which increases the carrier mobility and impedes carrier recombination. Devices based on these single-crystal hybrid perovskites show not only high stability against various degradation factors but also good performance (for example, solar cells based on lead-tin-gradient structures with an average efficiency of 18.77 per cent).

6.
Radiology ; 310(3): e232388, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38470238

RESUMO

Background Right atrial (RA) function strain is increasingly acknowledged as an important predictor of adverse events in patients with diverse cardiovascular conditions. However, the prognostic value of RA strain in patients with dilated cardiomyopathy (DCM) remains uncertain. Purpose To evaluate the prognostic value of RA strain derived from cardiac MRI (CMR) feature tracking (FT) in patients with DCM. Materials and Methods This multicenter, retrospective study included consecutive adult patients with DCM who underwent CMR between June 2010 and May 2022. RA strain parameters were obtained using CMR FT. The primary end points were sudden or cardiac death or heart transplant. Cox regression analysis was used to determine the association of variables with outcomes. Incremental prognostic value was evaluated using C indexes and likelihood ratio tests. Results A total of 526 patients with DCM (mean age, 51 years ± 15 [SD]; 381 male) were included. During a median follow-up of 41 months, 79 patients with DCM reached the primary end points. At univariable analysis, RA conduit strain was associated with the primary end points (hazard ratio [HR], 0.82 [95% CI: 0.76, 0.87]; P < .001). In multivariable Cox analysis, RA conduit strain was an independent predictor for the primary end points (HR, 0.83 [95% CI: 0.77, 0.90]; P < .001). A model combining RA conduit strain with other clinical and conventional imaging risk factors (C statistic, 0.80; likelihood ratio, 92.54) showed improved discrimination and calibration for the primary end points compared with models with clinical variables (C statistic, 0.71; likelihood ratio, 37.12; both P < .001) or clinical and imaging variables (C statistic, 0.75; likelihood ratio, 64.69; both P < .001). Conclusion CMR FT-derived RA conduit strain was an independent predictor of adverse outcomes among patients with DCM, providing incremental prognostic value when combined in a model with clinical and conventional CMR risk factors. Published under a CC BY 4.0 license. Supplemental material is available for this article.


Assuntos
Cardiomiopatia Dilatada , Adulto , Humanos , Masculino , Pessoa de Meia-Idade , Cardiomiopatia Dilatada/diagnóstico por imagem , Função do Átrio Direito , Estudos Retrospectivos , Imageamento por Ressonância Magnética , Radiografia
7.
BMC Cancer ; 24(1): 280, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38429653

RESUMO

OBJECTIVE: The risk category of gastric gastrointestinal stromal tumors (GISTs) are closely related to the surgical method, the scope of resection, and the need for preoperative chemotherapy. We aimed to develop and validate convolutional neural network (CNN) models based on preoperative venous-phase CT images to predict the risk category of gastric GISTs. METHOD: A total of 425 patients pathologically diagnosed with gastric GISTs at the authors' medical centers between January 2012 and July 2021 were split into a training set (154, 84, and 59 with very low/low, intermediate, and high-risk, respectively) and a validation set (67, 35, and 26, respectively). Three CNN models were constructed by obtaining the upper and lower 1, 4, and 7 layers of the maximum tumour mask slice based on venous-phase CT Images and models of CNN_layer3, CNN_layer9, and CNN_layer15 established, respectively. The area under the receiver operating characteristics curve (AUROC) and the Obuchowski index were calculated to compare the diagnostic performance of the CNN models. RESULTS: In the validation set, CNN_layer3, CNN_layer9, and CNN_layer15 had AUROCs of 0.89, 0.90, and 0.90, respectively, for low-risk gastric GISTs; 0.82, 0.83, and 0.83 for intermediate-risk gastric GISTs; and 0.86, 0.86, and 0.85 for high-risk gastric GISTs. In the validation dataset, CNN_layer3 (Obuchowski index, 0.871) provided similar performance than CNN_layer9 and CNN_layer15 (Obuchowski index, 0.875 and 0.873, respectively) in prediction of the gastric GIST risk category (All P >.05). CONCLUSIONS: The CNN based on preoperative venous-phase CT images showed good performance for predicting the risk category of gastric GISTs.


Assuntos
Tumores do Estroma Gastrointestinal , Neoplasias Gástricas , Humanos , Tumores do Estroma Gastrointestinal/diagnóstico por imagem , Tumores do Estroma Gastrointestinal/cirurgia , Tomografia Computadorizada por Raios X/métodos , Neoplasias Gástricas/diagnóstico por imagem , Neoplasias Gástricas/cirurgia , Redes Neurais de Computação , Curva ROC
8.
Liver Int ; 44(6): 1351-1362, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38436551

RESUMO

BACKGROUND AND AIMS: Accurate preoperative prediction of microvascular invasion (MVI) and recurrence-free survival (RFS) is vital for personalised hepatocellular carcinoma (HCC) management. We developed a multitask deep learning model to predict MVI and RFS using preoperative MRI scans. METHODS: Utilising a retrospective dataset of 725 HCC patients from seven institutions, we developed and validated a multitask deep learning model focused on predicting MVI and RFS. The model employs a transformer architecture to extract critical features from preoperative MRI scans. It was trained on a set of 234 patients and internally validated on a set of 58 patients. External validation was performed using three independent sets (n = 212, 111, 110). RESULTS: The multitask deep learning model yielded high MVI prediction accuracy, with AUC values of 0.918 for the training set and 0.800 for the internal test set. In external test sets, AUC values were 0.837, 0.815 and 0.800. Radiologists' sensitivity and inter-rater agreement for MVI prediction improved significantly when integrated with the model. For RFS, the model achieved C-index values of 0.763 in the training set and ranged between 0.628 and 0.728 in external test sets. Notably, PA-TACE improved RFS only in patients predicted to have high MVI risk and low survival scores (p < .001). CONCLUSIONS: Our deep learning model allows accurate MVI and survival prediction in HCC patients. Prospective studies are warranted to assess the clinical utility of this model in guiding personalised treatment in conjunction with clinical criteria.


Assuntos
Carcinoma Hepatocelular , Aprendizado Profundo , Neoplasias Hepáticas , Imageamento por Ressonância Magnética , Invasividade Neoplásica , Humanos , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/patologia , Carcinoma Hepatocelular/mortalidade , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Neoplasias Hepáticas/mortalidade , Imageamento por Ressonância Magnética/métodos , Estudos Retrospectivos , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Microvasos/diagnóstico por imagem , Microvasos/patologia , Intervalo Livre de Doença , Recidiva Local de Neoplasia
9.
Eur Radiol ; 34(8): 4852-4863, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38216755

RESUMO

OBJECTIVES: To evaluate the value of CT-based whole lung radiomics nomogram for identifying the risk of cardiovascular disease (CVD) in patients with chronic obstructive pulmonary disease (COPD). MATERIALS AND METHODS: A total of 974 patients with COPD were divided into a training cohort (n = 402), an internal validation cohort (n = 172), and an external validation cohort (n = 400) from three hospitals. Clinical data and CT findings were analyzed. Radiomics features of whole lung were extracted from the non-contrast chest CT images. A radiomics signature was constructed with algorithms. Combined with the radiomics score and independent clinical factors, multivariate logistic regression analysis was used to establish a radiomics nomogram. ROC curve was used to analyze the prediction performance of the model. RESULTS: Age, weight, and GOLD were the independent clinical factors. A total of 1218 features were extracted and reduced to 15 features to build the radiomics signature. In the training cohort, the combined model (area under the curve [AUC], 0.731) showed better discrimination capability (p < 0.001) than the clinical factors model (AUC, 0.605). In the internal validation cohort, the combined model (AUC, 0.727) performed better (p = 0.032) than the clinical factors model (AUC, 0.629). In the external validation cohort, the combined model (AUC, 0.725) performed better (p < 0.001) than the clinical factors model (AUC, 0.690). Decision curve analysis demonstrated the radiomics nomogram outperformed the clinical factors model. CONCLUSION: The CT-based whole lung radiomics nomogram has the potential to identify the risk of CVD in patients with COPD. CLINICAL RELEVANCE STATEMENT: This study helps to identify cardiovascular disease risk in patients with chronic obstructive pulmonary disease on chest CT scans. KEY POINTS: • To investigate the value of CT-based whole lung radiomics features in identifying the risk of cardiovascular disease in chronic obstructive pulmonary disease patients. • The radiomics nomogram showed better performance than the clinical factors model to identify the risk of cardiovascular disease in patients with chronic obstructive pulmonary disease. • The radiomics nomogram demonstrated excellent performance in the training, internal validation, and external validation cohort (AUC, 0.731; AUC, 0.727; AUC, 0.725).


Assuntos
Doenças Cardiovasculares , Nomogramas , Doença Pulmonar Obstrutiva Crônica , Tomografia Computadorizada por Raios X , Humanos , Doença Pulmonar Obstrutiva Crônica/diagnóstico por imagem , Doença Pulmonar Obstrutiva Crônica/complicações , Masculino , Feminino , Tomografia Computadorizada por Raios X/métodos , Doenças Cardiovasculares/diagnóstico por imagem , Pessoa de Meia-Idade , Idoso , Medição de Risco/métodos , Pulmão/diagnóstico por imagem , Fatores de Risco , Estudos Retrospectivos , Radiômica
10.
Eur Radiol ; 2024 Sep 19.
Artigo em Inglês | MEDLINE | ID: mdl-39299951

RESUMO

OBJECTIVE: To evaluate multisite effects on fetal brain MRI. Specifically, to identify crucial acquisition factors affecting fetal brain structural measurements and developmental patterns, while assessing the effectiveness of existing harmonization methods in mitigating site effects. MATERIALS AND METHODS: Between May 2017 and March 2022, T2-weighted fast spin-echo sequences in-utero MRI were performed on healthy fetuses from retrospectively recruited pregnant volunteers on four different scanners at four sites. A generalized additive model (GAM) was used to quantitatively assess site effects, including field strength (FS), manufacturer (M), in-plane resolution (R), and slice thickness (ST), on subcortical volume and cortical morphological measurements, including cortical thickness, curvature, and sulcal depth. Growth models were selected to elucidate the developmental trajectories of these morphological measurements. Welch's test was performed to evaluate the influence of site effects on developmental trajectories. The comBat-GAM harmonization method was applied to mitigate site-related biases. RESULTS: The final analytic sample consisted of 340 MRI scans from 218 fetuses (mean GA, 30.1 weeks ± 4.4 [range, 21.7-40 weeks]). GAM results showed that lower FS and lower spatial resolution led to overestimations in selected brain regions of subcortical volumes and cortical morphological measurements. Only the peak cortical thickness in developmental trajectories was significantly influenced by the effects of FS and R. Notably, ComBat-GAM harmonization effectively removed site effects while preserving developmental patterns. CONCLUSION: Our findings pinpointed the key acquisition factors in in-utero fetal brain MRI and underscored the necessity of data harmonization when pooling multisite data for fetal brain morphology investigations. KEY POINTS: Question How do specific site MRI acquisition factors affect fetal brain imaging? Finding Lower FS and spatial resolution overestimated subcortical volumes and cortical measurements. Cortical thickness in developmental trajectories was influenced by FS and in-plane resolution. Clinical relevance This study provides important guidelines for the fetal MRI community when scanning fetal brains and underscores the necessity of data harmonization of cross-center fetal studies.

11.
Neurol Sci ; 45(7): 3093-3105, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38381393

RESUMO

Post-sepsis psychiatric disorder, encompassing anxiety, depression, post-traumatic stress disorder and delirium, is a highly prevalent complication secondary to sepsis, resulting in a marked increase in long-term mortality among affected patients. Regrettably, psychiatric impairment associated with sepsis is frequently disregarded by clinicians. This review aims to summarize recent advancements in the understanding of the pathophysiology, prevention, and treatment of post-sepsis mental disorder, including coronavirus disease 2019-related psychiatric impairment. The pathophysiology of post-sepsis psychiatric disorder is complex and is known to involve blood-brain barrier disruption, overactivation of the hypothalamic-pituitary-adrenal axis, neuroinflammation, oxidative stress, neurotransmitter dysfunction, programmed cell death, and impaired neuroplasticity. No unified diagnostic criteria for this disorder are currently available; however, screening scales are often applied in its assessment. Modifiable risk factors for psychiatric impairment post-sepsis include the number of experienced traumatic memories, the length of ICU stay, level of albumin, the use of vasopressors or inotropes, daily activity function after sepsis, and the cumulative dose of dobutamine. To contribute to the prevention of post-sepsis psychiatric disorder, it may be beneficial to implement targeted interventions for these modifiable risk factors. Specific therapies for this condition remain scarce. Nevertheless, non-pharmacological approaches, such as comprehensive nursing care, may provide a promising avenue for treating psychiatric disorder following sepsis. In addition, although several therapeutic drugs have shown preliminary efficacy in animal models, further confirmation of their potential is required through follow-up clinical studies.


Assuntos
Transtornos Mentais , Sepse , Humanos , COVID-19/complicações , Delírio/etiologia , Delírio/terapia , Delírio/prevenção & controle , Delírio/fisiopatologia , Transtornos Mentais/etiologia , Transtornos Mentais/terapia , SARS-CoV-2 , Sepse/complicações , Sepse/fisiopatologia , Sepse/terapia , Transtornos de Estresse Pós-Traumáticos/terapia , Transtornos de Estresse Pós-Traumáticos/fisiopatologia , Transtornos de Estresse Pós-Traumáticos/etiologia
12.
Eur Radiol ; 33(4): 2301-2311, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36334102

RESUMO

OBJECTIVES: Hypertrophic cardiomyopathy (HCM) often requires repeated enhanced cardiac magnetic resonance (CMR) imaging to detect fibrosis. We aimed to develop a practical model based on cine imaging to help identify patients with high risk of fibrosis and screen out patients without fibrosis to avoid unnecessary injection of contrast. METHODS: A total of 273 patients with HCM were divided into training and test sets at a ratio of 7:3. Logistic regression analysis was used to find predictive image features to construct CMR model. Radiomic features were derived from the maximal wall thickness (MWT) slice and entire left ventricular (LV) myocardium. Extreme gradient boosting was used to build radiomic models. Integrated models were established by fusing image features and radiomic models. The model performance was validated in the test set and assessed by ROC and calibration curve and decision curve analysis (DCA). RESULTS: We established five prediction models, including CMR, R1 (based on the MWT slice), R2 (based on the entire LV myocardium), and two integrated models (ICMR+R1 and ICMR+R2). In the test set, ICMR+R2 model had an excellent AUC value (0.898), diagnostic accuracy (89.02%), sensitivity (92.54%), and F1 score (93.23%) in identifying patients with positive late gadolinium enhancement. The calibration plots and DCA indicated that ICMR+R2 model was well-calibrated and presented a better net benefit than other models. CONCLUSIONS: A predictive model that fused image and radiomic features from the entire LV myocardium had good diagnostic performance, robustness, and clinical utility. KEY POINTS: • Hypertrophic cardiomyopathy is prone to fibrosis, requiring patients to undergo repeated enhanced cardiac magnetic resonance imaging to detect fibrosis over their lifetime follow-up. • A predictive model based on the entire left ventricular myocardium outperformed a model based on a slice of the maximal wall thickness. • A predictive model that fused image and radiomic features from the entire left ventricular myocardium had excellent diagnostic performance, robustness, and clinical utility.


Assuntos
Cardiomiopatia Hipertrófica , Meios de Contraste , Humanos , Meios de Contraste/farmacologia , Imagem Cinética por Ressonância Magnética/métodos , Gadolínio , Cardiomiopatia Hipertrófica/diagnóstico por imagem , Imageamento por Ressonância Magnética , Miocárdio/patologia , Fibrose , Espectroscopia de Ressonância Magnética , Valor Preditivo dos Testes
13.
Molecules ; 28(23)2023 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-38067486

RESUMO

In recent years, the coagulation properties of inorganic minerals such as kaolin and zeolite have been demonstrated. This study aimed to assess the hemostatic properties of three local clays from China: natural kaolin from Hainan, natural halloysite from Yunnan, and zeolite synthesized by our group. The physical and chemical properties, blood coagulation performance, and cell biocompatibility of the three materials were tested. The studied materials were characterized by using scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FTIR), X-ray diffraction (XRD), X-ray fluorescence spectroscopy (XRF), thermogravimetric analysis (TGA), and differential scanning calorimetry (DSC). All three clays showed different morphologies and particle size, and exhibited negative potentials between pH 6 and 8. The TGA and DSC curves for kaolin and halloysite were highly similar. Kaolin showed the highest water absorption capacity (approximately 93.8% ± 0.8%). All three clays were noncytotoxic toward L929 mouse fibroblasts. Kaolin and halloysite showed blood coagulation effects similar to that exhibited by zeolite, indicating that kaolin and halloysite are promising alternative hemostatic materials.


Assuntos
Hemostáticos , Zeolitas , Animais , Camundongos , Argila/química , Caulim/farmacologia , Caulim/química , China
14.
Eur Radiol ; 32(6): 3808-3818, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35103828

RESUMO

BACKGROUND AND OBJECTIVE: Decreasing X-ray tube voltage is an effective way to reduce radiation and contrast dose, especially in non-obese patients. The current study focuses on CTA in non-obese patients to evaluate image quality and feasibility of 80-kV acquisition protocols with varying iodine delivery rates (IDR) and contrast concentrations in routine clinical practice. METHODS: A prospective observational study in patients ≥ 18 years and ≤ 90 kg referred for coronary or craniocervical CTA at 10 centers in China (ClinicalTrials.gov: NCT02840903). Patients were divided into four groups: a standard 100-kV protocol (370 mgI/ml, IDR 1.48 gI/s), and three 80-kV protocols (370 mgI/ml, IDR 1.2 gI/s; 300 mgI/ml, IDR 1.2 gI/s; 300 mgI/ml, IDR 0.96gI/s). The primary outcome was contrast opacification of target vascular segments. Secondary outcomes were image quality (contrast-to-noise ratio, signal-to-noise ratio, visual image quality, and diagnostic confidence assessment), radiation, and iodine dose. RESULTS: From July 2016 to July 2017, 1213 patients were enrolled: 614 coronary and 599 craniocervical CTA. The mean contrast opacification was ≥ 300 HU for 80-kV 1.2 gI/s IDR scanned segments; IDR 0.96 gI/s led to lower opacification. Image quality and diagnostic confidence were fair to excellent (≥ 98% of images), despite lower contrast-to-noise ratios and signal-to-noise ratios in 80-kV images. Compared to the standard protocol, 80-kV protocols led to 44-52% radiation dose reductions (p < 0.001) and 19% iodine dose reductions (p < 0.001). CONCLUSION: Eighty-kilovolt 1.2 gI/s IDR protocols can be recommended for coronary and craniocervical CTA in non-obese patients, reducing radiation and iodine dose without compromising image quality. KEY POINTS: • Using low-voltage scanning CTA protocols, in which tube voltage and iodine delivery rate are reduced proportionally (voltage: 80 kV, IDR: 1.2 gI/s), reduces radiation and contrast dose without compromising image quality in routine clinical practice. • Reducing iodine delivery rate beyond direct proportionality to tube voltage is not beneficial.


Assuntos
Angiografia por Tomografia Computadorizada , Iodo , Angiografia por Tomografia Computadorizada/métodos , Meios de Contraste , Angiografia Coronária/métodos , Humanos , Estudos Prospectivos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Resultado do Tratamento
15.
Nano Lett ; 21(5): 2199-2206, 2021 03 10.
Artigo em Inglês | MEDLINE | ID: mdl-33600181

RESUMO

Liver metastasis (LM) occurs in various cancers, and its early and accurate diagnosis is of great importance. However, the detection of small LMs is still a great challenge because of the subtle differences between normal liver tissue and small metastases. Herein, we prepare glutathione (GSH)-responsive hyaluronic acid-coated iron oxide nanoparticles (HIONPs) for highly sensitive diagnosis of LMs through a facile one-pot method. HIONPs greatly enhance the signal of MRI in tumor metastases as T1 contrast agent (CA), whereas they substantially decrease the signal of liver as T2 CA as they aggregate into clusters upon the high GSH in liver. Consequently, MRI contrasted by HIONPs clearly distinguishes metastatic tumors (bright) from surrounding liver tissues (dark). HIONPs with superior LM contrasting capability and facile synthesis are very promising for clinical translation and indicate a new strategy to develop an ultrasensitive MRI CA for LM diagnosis that exploits high GSH level in the liver.


Assuntos
Neoplasias Hepáticas , Nanopartículas de Magnetita , Nanopartículas , Meios de Contraste , Glutationa , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Imageamento por Ressonância Magnética
16.
BMC Urol ; 21(1): 107, 2021 Aug 13.
Artigo em Inglês | MEDLINE | ID: mdl-34388999

RESUMO

BACKGROUND: To explore the risk factors for severe bleeding complications after percutaneous nephrolithotomy (PCNL) according to the modified Clavien scoring system. METHODS: We retrospectively analysed 2981 patients who received percutaneous nephrolithotomies from January 2014 to December 2020. Study inclusion criteria were PCNL and postoperative mild or severe renal haemorrhage in accordance with the modified Clavien scoring system. Mild bleeding complications included Clavien 2, while severe bleeding complications were greater than Clavien 3a. It has a good prognosis and is more likely to be underestimated and ignored in retrospective studies in bleeding complications classified by Clavien 1, so no analysis about these was conducted in this study. Clinical features, medical comorbidities and perioperative characteristics were analysed. Chi-square, independent t tests, Pearson's correlation, Fisher exact tests, Mann-Whitney and multivariate logistic regression were used as appropriate. RESULTS: Of the 2981 patients 70 (2.3%), met study inclusion criteria, consisting of 51 men and 19 women, 48 patients had severe bleeding complications. The remaining 22 patients had mild bleeding. Patients with postoperative severe bleeding complications were more likely to have no or slight degree of hydronephrosis and have no staghorn calculi on univariate analysis (p < 0.05). Staghorn calculi (OR, 95% CI, p value 0.218, 0.068-0.700, 0.010) and hydronephrosis (OR, 95% CI, p value 0.271, 0.083-0.887, 0.031) were independent predictors for severe bleeding via multivariate logistic regression analysis. Other factors, such as history of PCNL, multiple kidney stones, site of puncture calyx and mean corrected intraoperative haemoglobin drop were not related to postoperative severe bleedings. CONCLUSIONS: The absence of staghorn calculi and a no or mild hydronephrosis were related to an increased risk of post-percutaneous nephrolithotomy severe bleeding complications.


Assuntos
Hidronefrose/complicações , Cálculos Renais/cirurgia , Nefrolitotomia Percutânea/efeitos adversos , Hemorragia Pós-Operatória/etiologia , Cálculos Coraliformes , Idoso , Feminino , Humanos , Cálculos Renais/complicações , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco
17.
Andrologia ; 53(5): e14012, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33616285

RESUMO

Diffusion tensor imaging (DTI) is a functional magnetic resonance sequence based on the movement of water molecules. This study attempted to investigate the feasibility of DTI in evaluating testicular injury after testicular torsion and detorsion. Seventy-two rats were randomly divided into the sham group, torsion group and detorsion group. The left testis in the sham group was brought out through a scrotal incision for 1 hr, and that of the torsion group was twisted 720o clockwise for 1 hr and fixed to the scrotum, while the detorsion group was restored after being twisted 720° for 1 hr. Rats were further divided into four subgroups according to the set time, then performed DTI and histology analysis. The mean diffusion of the torsion and detorsion groups increased within 24 hr (p <.01), while it in the detorsion-1-week-group was lower than that in the detorsion-24-hr-group (p <.05). The fraction anisotropy of both experimental groups decreased in the acute phase (p <.01), while that of the detorsion-1-week-group increased (p <.01). Cosentino score in both experimental groups showed an increasing trend (p <.05). Besides, the spermatogenic ability of the detorsion-1-week-group decreased (p <.05). In conclusion, DTI was able to evaluate the injury after testicular torsion and detorsion.


Assuntos
Traumatismo por Reperfusão , Torção do Cordão Espermático , Animais , Imagem de Tensor de Difusão , Humanos , Masculino , Malondialdeído , Ratos , Torção do Cordão Espermático/diagnóstico por imagem , Espermatogênese , Testículo/diagnóstico por imagem , Testículo/cirurgia
18.
Nano Lett ; 20(6): 4445-4453, 2020 06 10.
Artigo em Inglês | MEDLINE | ID: mdl-32368921

RESUMO

Thermoelectric generators (TEGs) provide a unique solution for energy harvesting from waste heat, presenting a potential solution for green energy. However, traditional rigid and flexible TEGs cannot work on complex and dynamic surfaces. Here, we report a stretchable TEG (S-TEG) (over 50% stretchability of the entire device) that is geometrically suitable for various complex and dynamic surfaces of heat sources. The S-TEG consists of hot-pressed nanolayered p-(Sb2Te3) and n-(Bi2Te3)-type thermoelectric couple arrays and exploits the wavy serpentine interconnects to integrate all units. The internal resistance of a 10 × 10 array is 22 ohm, and the output power is ∼0.15 mW/cm2 at ΔT = 19 K on both developable and nondevelopable surfaces, which are much improved compared with those of existing S-TEGs. The energy harvesting of S-TEG from the dynamic surfaces of the human skin offers a potential energy solution for the wearable devices for health monitoring.

19.
Can Assoc Radiol J ; 72(3): 444-451, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32106696

RESUMO

PURPOSE: To discuss significant computed tomography (CT) findings that differentiate gastric leiomyomas (GLs) from small gastric stromal tumors (GSTs). METHODS: One hundred sixty cases with pathologically proven GLs (n = 50) and GSTs (n = 110) with comprehensive CT images were enrolled in this retrospective study. Computed tomography findings (ie, size, location, contour, growth pattern, enhancement degree, necrosis, ulceration, calcification, and lymph nodes) were analyzed through the χ2 or Fisher exact test, independent T test, and multivariate (logistic regression) analysis. Sensitivity and specificity were also calculated. RESULTS: Features of cardia location, endophytic growth, homogeneous gradual enhancement, absent of necrosis, long diameter less than 24 mm, short diameter less than 20 mm, unenhanced CT value larger than 35.2 Hounsfield units (HU), portal venous phase CT value larger than 67.4 HU, and enhancement degree of arterial and venous phase less than 16.2 HU and 32.4 HU were found to be statistically significant between GLs and small GSTs (P < .05). On multivariate analysis, cardia location, endophytic growth, and homogeneous gradual enhancement were independent predictive factors for GLs and small GSTs. CONCLUSION: These 10 CT criteria are very helpful to differentiate GLs from small GSTs. Especially cardia location, endophytic growth, and homogeneous gradual enhancement are of high value in differential diagnosis.


Assuntos
Tumores do Estroma Gastrointestinal/diagnóstico por imagem , Leiomioma/diagnóstico por imagem , Neoplasias Gástricas/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Cárdia , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
20.
BMC Pulm Med ; 20(1): 161, 2020 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-32503511

RESUMO

BACKGROUND: Pulmonary Cryptococcosis is a common fungal infection mainly caused by Cryptococcus neoformans/C.gattii species in immunocompromised patients. Cases of pulmonary cryptococcosis in patients with normal immune function are increasingly common in China. Clinical and radiographic features of pulmonary cryptococcosis are various and without obvious characteristics, so it is often misdiagnosed as pulmonary metastatic tumor or tuberculosis. When coexisting with malignant lung tumors, it was more difficult to differentiate from metastatic lung cancer, although the coexistence of pulmonary cryptococcosis and central type lung cancer is rare. Reviewing the imaging manifestations and diagnosis of the case and the relevant literature will contribute to recognition of the disease and a decrease in misdiagnoses. CASE PRESENTATION: A 72-year-old immunocompetent Han Chinese man had repeated dry cough for more than half a year. CT examination of chest showed an irregular mass at the left hilum of the lung, and two small nodules in the right lung, which were considered as the left central lung cancer with right lung metastasis. However, the patient was diagnosed with pulmonary cryptococcosis coexisting with central type lung cancer based on the results of laboratory examination, percutaneous lung biopsy, fiberoptic bronchoscopy, and surgical pathology. The patient underwent surgical resection of the left central type lung cancer and was placed on fluconazole treatment after a positive diagnosis was made. Five years after the lung cancer surgery, the patient had a recurrence, but the pulmonary cryptococcus nodule disappeared. CONCLUSION: Our case shows that CT findings of central type lung cancer with multiple pulmonary nodules are not necessarily metastases, but may be coexisting pulmonary cryptococcosis. CT images of cryptococcosis of the lung were diverse and have no obvious characteristics, so it was very difficult to distinguish from metastatic tumors. CT-guided percutaneous lung biopsy was a simple and efficient method for identification.


Assuntos
Criptococose/tratamento farmacológico , Fluconazol/uso terapêutico , Pneumopatias Fúngicas/tratamento farmacológico , Neoplasias Pulmonares/microbiologia , Neoplasias Pulmonares/patologia , Idoso , Comorbidade , Humanos , Imunocompetência , Neoplasias Pulmonares/cirurgia , Masculino , Recidiva Local de Neoplasia/patologia , Tomografia Computadorizada por Raios X , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa