Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 45
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Br J Anaesth ; 133(4): 748-751, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39095237

RESUMO

Myocardial injury after noncardiac surgery (MINS) and perioperative myocardial injury are associated with increased morbidity and mortality. Both are diagnosed by a perioperative increase in troponin, yet there is controversy if MINS is a genuine myocardial insult. We applied postoperative cardiovascular magnetic resonance T2 mapping techniques to visualise acute myocardial injury (i.e. oedema) in six patients with multiple cardiovascular risk factors who underwent aortic surgery. The burden of myocardial oedema was substantially higher in four patients with elevated troponin qualifying for MINS, compared with patients without MINS. The data and images suggest that MINS represents genuine myocardial injury.


Assuntos
Imageamento por Ressonância Magnética , Complicações Pós-Operatórias , Humanos , Masculino , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/etiologia , Idoso , Feminino , Pessoa de Meia-Idade , Imageamento por Ressonância Magnética/métodos , Troponina/sangue , Idoso de 80 Anos ou mais , Edema/diagnóstico por imagem , Edema/etiologia
2.
Eur J Anaesthesiol ; 41(7): 480-489, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38323332

RESUMO

BACKGROUND: Induction of general anaesthesia has many potential triggers for peri-operative myocardial ischaemia including the acute disturbance of blood gases that frequently follows alterations in breathing and ventilation patterns. Free-breathing oxygenation-sensitive cardiovascular magnetic resonance (OS-CMR) imaging may provide the opportunity to continuously quantify the impact of such triggers on myocardial oxygenation. OBJECTIVE: To investigate the impact of breathing patterns that simulate induction of general anaesthesia on myocardial oxygenation in awake healthy adults using continuous OS-CMR imaging. DESIGN: Prospective observational study. SETTING: Single-centre university hospital. Recruitment from August 2020 to January 2022. PARTICIPANTS: Thirty-two healthy volunteers younger than 45 years old were recruited. Data were analysed from n  = 29 (69% male individuals). INTERVENTION: Participants performed a simulated induction breathing manoeuvre consisting of 2.5 min paced breathing with a respiration rate of 14 breaths per minute, followed by 5 deep breaths, then apnoea for up to 60s inside a magnetic resonance imaging scanner (MRI). Cardiac images were acquired with the traditional OS-CMR sequence (OS bh-cine ), which requires apnoea for acquisition and with two free-breathing OS-CMR sequences: a high-resolution single-shot sequence (OS fb-ss ) and a real-time cine sequence (OS fb-rtcine ). MAIN OUTCOME MEASURES: Myocardial oxygenation response at the end of the paced breathing period and at the 30 s timepoint during the subsequent apnoea, reflecting the time of successful intubation in a clinical setting. RESULTS: The paced breathing followed by five deep breaths significantly reduced myocardial oxygenation, which was observed with all three techniques (OS bh-cine -6.0 ±â€Š2.6%, OS fb-ss -12.0 ±â€Š5.9%, OS fb-rtcine -5.4 ±â€Š7.0%, all P  < 0.05). The subsequent vasodilating stimulus of apnoea then significantly increased myocardial oxygenation (OS bh-cine 6.8 ±â€Š3.1%, OS fb-ss 8.4 ±â€Š5.6%, OS fb-rtcine 15.7 ±â€Š10.0%, all P  < 0.01). The free-breathing sequences were reproducible and were not inferior to the original sequence for any stage. CONCLUSION: Breathing manoeuvres simulating induction of general anaesthesia cause dynamic alterations of myocardial oxygenation in young volunteers, which can be quantified continuously with free-breathing OS-CMR. Introducing these new imaging techniques into peri-operative studies may throw new light into the mechanisms of peri-operative perturbations of myocardial tissue oxygenation and ischaemia. VISUAL ABSTRACT: http://links.lww.com/EJA/A922.


Assuntos
Imageamento por Ressonância Magnética , Humanos , Masculino , Adulto , Estudos Prospectivos , Feminino , Imageamento por Ressonância Magnética/métodos , Estudos de Coortes , Respiração , Miocárdio/metabolismo , Anestesia Geral/métodos , Voluntários Saudáveis , Oxigênio/sangue , Oxigênio/metabolismo , Adulto Jovem , Imagem Cinética por Ressonância Magnética/métodos
3.
Circulation ; 145(10): 724-738, 2022 03 08.
Artigo em Inglês | MEDLINE | ID: mdl-34747186

RESUMO

BACKGROUND: No study has so far compared Amulet with the new Watchman FLX in terms of residual left atrial appendage (LAA) patency or clinical outcomes in patients undergoing percutaneous LAA closure. METHODS: In the investigator-initiated SWISS APERO trial (Comparison of Amulet Versus Watchman/FLX Device in Patients Undergoing Left Atrial Appendage Closure), patients undergoing LAA closure were randomly assigned (1:1) open label to receive Amulet or Watchman 2.5 or FLX (Watchman) across 8 European centers. The primary end point was the composite of justified crossover to a nonrandomized device during LAA closure procedure or residual LAA patency detected by cardiac computed tomography angiography (CCTA) at 45 days. The secondary end points included procedural complications, device-related thrombus, peridevice leak at transesophageal echocardiography, and clinical outcomes at 45 days. RESULTS: Between June 2018 and May 2021, 221 patients were randomly assigned to Amulet (111 [50.2%]) or Watchman (110 [49.8%]), of whom 25 (22.7%) patients included before October 2019 received Watchman 2.5, and 85 (77.3%) patients received Watchman FLX. The primary end point was assessable in 205 (92.8%) patients and occurred in 71 (67.6%) patients receiving Amulet and 70 (70.0%) patients receiving Watchman, respectively (risk ratio, 0.97 [95% CI, 0.80-1.16]; P=0.713). A single justified crossover occurred in a patient with Amulet who fulfilled LAA patency criteria at 45-day CCTA. Major procedure-related complications occurred more frequently in the Amulet group (9.0% versus 2.7%; P=0.047) because of more frequent bleeding (7.2% versus 1.8%). At 45 days, the peridevice leak rate at transesophageal echocardiography was higher with Watchman than with Amulet (27.5% versus 13.7%, P=0.020), albeit none was major (ie, >5 mm), whereas device-related thrombus was detected in 1 (0.9%) patient with Amulet and 3 (3.0%) patients with Watchman at CCTA and in 2 (2.1%) and 5 (5.5%) patients at transesophageal echocardiography, respectively. Clinical outcomes at 45 days did not differ between the groups. CONCLUSIONS: Amulet was not associated with a lower rate of the composite of crossover or residual LAA patency compared with Watchman at 45-day CCTA. Amulet, however, was associated with lower peridevice leak rates at transesophageal echocardiography, higher procedural complications, and similar clinical outcomes at 45 days compared with Watchman. The clinical relevance of CCTA-detected LAA patency requires further investigation. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT03399851.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Procedimentos Cirúrgicos Cardíacos , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Cateterismo Cardíaco/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Ecocardiografia Transesofagiana/métodos , Humanos , Resultado do Tratamento
4.
Eur Radiol ; 33(10): 7226-7237, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37145149

RESUMO

OBJECTIVES: Atrial function can be assessed using advancing cardiovascular magnetic resonance (CMR) post-processing methods: atrial feature tracking (FT) strain analysis or a long-axis shortening (LAS) technique. This study aimed to first compare the two FT and LAS techniques in healthy individuals and cardiovascular patients and then investigated how left (LA) and right atrial (RA) measurements are related to the severity of diastolic dysfunction or atrial fibrillation. METHODS: Sixty healthy controls and 90 cardiovascular disease patients with coronary artery disease, heart failure, or atrial fibrillation, underwent CMR. LA and RA were analyzed for standard volumetry as well as for myocardial deformation using FT and LAS for the different functional phases (reservoir, conduit, booster). Additionally, ventricular shortening and valve excursion measurements were assessed with the LAS module. RESULTS: The measurements for each of the LA and RA phases were correlated (p < 0.05) between the two approaches, with the highest correlation coefficients occurring in the reservoir phase (LA: r = 0.83, p < 0.01, RA: r = 0.66, p < 0.01). Both methods demonstrated reduced LA (FT: 26 ± 13% vs 48 ± 12%, LAS: 25 ± 11% vs 42 ± 8%, p < 0.01) and RA reservoir function (FT: 28 ± 15% vs 42 ± 15%, LAS: 27 ± 12% vs 42 ± 10%, p < 0.01) in patients compared to controls. Atrial LAS and FT decreased with diastolic dysfunction and atrial fibrillation. This mirrored ventricular dysfunction measurements. CONCLUSION: Similar results were generated for bi-atrial function measurements between two CMR post-processing approaches of FT and LAS. Moreover, these methods allowed for the assessment of incremental deterioration of LA and RA function with increasing left ventricular diastolic dysfunction and atrial fibrillation. A CMR-based analysis of bi-atrial strain or shortening discriminates patients with early-stage diastolic dysfunction prior to the presence of compromised atrial and ventricular ejection fractions that occur with late-stage diastolic dysfunction and atrial fibrillation. KEY POINTS: • Assessing right and left atrial function with CMR feature tracking or long-axis shortening techniques yields similar measurements and could potentially be used interchangeably based on the software capabilities of individual sites. • Atrial deformation and/or long-axis shortening allow for early detection of subtle atrial myopathy in diastolic dysfunction, even when atrial enlargement is not yet apparent. • Using a CMR-based analysis to understand the individual atrial-ventricular interaction in addition to tissue characteristics allows for a comprehensive interrogation of all four heart chambers. In patients, this could add clinically meaningful information and potentially allow for optimal therapies to be chosen to better target the dysfunction.


Assuntos
Fibrilação Atrial , Cardiomiopatias , Disfunção Ventricular Esquerda , Humanos , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética , Átrios do Coração/diagnóstico por imagem , Disfunção Ventricular Esquerda/diagnóstico por imagem , Função do Átrio Esquerdo
5.
Eur Radiol ; 2023 Oct 23.
Artigo em Inglês | MEDLINE | ID: mdl-37870625

RESUMO

OBJECTIVES: The purpose of this study was to determine the influence of dose reduction on a commercially available lung cancer prediction convolutional neuronal network (LCP-CNN). METHODS: CT scans from a cohort provided by the local lung cancer center (n = 218) with confirmed pulmonary malignancies and their corresponding reduced dose simulations (25% and 5% dose) were subjected to the LCP-CNN. The resulting LCP scores (scale 1-10, increasing malignancy risk) and the proportion of correctly classified nodules were compared. The cohort was divided into a low-, medium-, and high-risk group based on the respective LCP scores; shifts between the groups were studied to evaluate the potential impact on nodule management. Two different malignancy risk score thresholds were analyzed: a higher threshold of ≥ 9 ("rule-in" approach) and a lower threshold of > 4 ("rule-out" approach). RESULTS: In total, 169 patients with 196 nodules could be included (mean age ± SD, 64.5 ± 9.2 year; 49% females). Mean LCP scores for original, 25% and 5% dose levels were 8.5 ± 1.7, 8.4 ± 1.7 (p > 0.05 vs. original dose) and 8.2 ± 1.9 (p < 0.05 vs. original dose), respectively. The proportion of correctly classified nodules with the "rule-in" approach decreased with simulated dose reduction from 58.2 to 56.1% (p = 0.34) and to 52.0% for the respective dose levels (p = 0.01). For the "rule-out" approach the respective values were 95.9%, 96.4%, and 94.4% (p = 0.12). When reducing the original dose to 25%/5%, eight/twenty-two nodules shifted to a lower, five/seven nodules to a higher malignancy risk group. CONCLUSION: CT dose reduction may affect the analyzed LCP-CNN regarding the classification of pulmonary malignancies and potentially alter pulmonary nodule management. CLINICAL RELEVANCE STATEMENT: Utilization of a "rule-out" approach with a lower malignancy risk threshold prevents underestimation of the nodule malignancy risk for the analyzed software, especially in high-risk cohorts. KEY POINTS: • LCP-CNN may be affected by CT image parameters such as noise resulting from low-dose CT acquisitions. • CT dose reduction can alter pulmonary nodule management recommendations by affecting the outcome of the LCP-CNN. • Utilization of a lower malignancy risk threshold prevents underestimation of pulmonary malignancies in high-risk cohorts.

6.
J Cardiovasc Magn Reson ; 25(1): 49, 2023 08 17.
Artigo em Inglês | MEDLINE | ID: mdl-37587516

RESUMO

BACKGROUND: Recent evidence underlined the importance of right (RV) involvement in suspected myocarditis. We aim to analyze the possible incremental prognostic value from RV global longitudinal strain (GLS) by CMR. METHODS: Patients referred for CMR, meeting clinical criteria for suspected myocarditis and no other cardiomyopathy were enrolled in a dual-center register cohort study. Ejection fraction (EF), GLS and tissue characteristics were assessed in both ventricles to assess their association to first major adverse cardiovascular events (MACE) including hospitalization for heart failure (HF), ventricular tachycardia (VT), recurrent myocarditis and death. RESULTS: Among 659 patients (62.8% male; 48.1 ± 16.1 years), RV GLS was impaired (> - 15.4%) in 144 (21.9%) individuals, of whom 76 (58%), 108 (77.1%), 27 (18.8%) and 40 (32.8%) had impaired right ventricular ejection fraction (RVEF), impaired left ventricular ejection fraction (LVEF), RV late gadolinium enhancement (LGE) or RV edema, respectively. After a median observation time of 3.7 years, 45 (6.8%) patients were hospitalized for HF, 42 (6.4%) patients died, 33 (5%) developed VT and 16 (2.4%) had recurrent myocarditis. Impaired RV GLS was associated with MACE (HR = 1.07, 95% CI 1.04-1.10; p < 0.001), HF hospitalization (HR = 1.17, 95% CI 1.12-1.23; p < 0.001), and death (HR = 1.07, 95% CI 1.02-1.12; p = 0.004), but not with VT and recurrent myocarditis in univariate analysis. RV GLS lost its association with outcomes, when adjusted for RVEF, LVEF, LV GLS and LV LGE extent. CONCLUSION: RV strain is associated with MACE, HF hospitalization and death but has neither independent nor incremental prognostic value after adjustment for RV and LV function and tissue characteristics. Therefore, assessing RV GLS in the setting of myocarditis has only limited value.


Assuntos
Insuficiência Cardíaca , Miocardite , Taquicardia Ventricular , Humanos , Masculino , Feminino , Miocardite/diagnóstico por imagem , Volume Sistólico , Estudos de Coortes , Meios de Contraste , Gadolínio , Função Ventricular Esquerda , Função Ventricular Direita , Valor Preditivo dos Testes , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Espectroscopia de Ressonância Magnética
7.
Eur Radiol ; 32(6): 4324-4332, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35059804

RESUMO

OBJECTIVES: This study was conducted to evaluate the effect of dose reduction on the performance of a deep learning (DL)-based computer-aided diagnosis (CAD) system regarding pulmonary nodule detection in a virtual screening scenario. METHODS: Sixty-eight anthropomorphic chest phantoms were equipped with 329 nodules (150 ground glass, 179 solid) with four sizes (5 mm, 8 mm, 10 mm, 12 mm) and scanned with nine tube voltage/current combinations. The examinations were analyzed by a commercially available DL-based CAD system. The results were compared by a comparison of proportions. Logistic regression was performed to evaluate the impact of tube voltage, tube current, nodule size, nodule density, and nodule location. RESULTS: The combination with the lowest effective dose (E) and unimpaired detection rate was 80 kV/50 mAs (sensitivity: 97.9%, mean false-positive rate (FPR): 1.9, mean CTDIvol: 1.2 ± 0.4 mGy, mean E: 0.66 mSv). Logistic regression revealed that tube voltage and current had the greatest impact on the detection rate, while nodule size and density had no significant influence. CONCLUSIONS: The optimal tube voltage/current combination proposed in this study (80 kV/50 mAs) is comparable to the proposed combinations in similar studies, which mostly dealt with conventional CAD software. Modification of tube voltage and tube current has a significant impact on the performance of DL-based CAD software in pulmonary nodule detection regardless of their size and composition. KEY POINTS: • Modification of tube voltage and tube current has a significant impact on the performance of deep learning-based CAD software. • Nodule size and composition have no significant impact on the software's performance. • The optimal tube voltage/current combination for the examined software is 80 kV/50 mAs.


Assuntos
Aprendizado Profundo , Neoplasias Pulmonares , Nódulo Pulmonar Solitário , Algoritmos , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Sensibilidade e Especificidade , Nódulo Pulmonar Solitário/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos
8.
Eur Radiol ; 32(5): 3436-3446, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34932165

RESUMO

OBJECTIVES: Cardiovascular magnetic resonance feature tracking (CMR-FT) is an emerging technique for assessing myocardial strain with valuable diagnostic and prognostic potential. However, the reproducibility of biventricular CMR-FT analysis in a large cardiovascular population has not been assessed. Also, evidence of confounders impacting reader reproducibility for CMR-FT in patients is unknown and currently limits the clinical implementation of this technique. METHODS: From a dual-center database of patients referred to CMR for suspected myocarditis, 125 patients were randomly selected to undergo biventricular CMR-FT analysis for 2-dimensional systolic and diastolic measures, with additional 3-dimensional analysis for the left ventricle. All image analysis was replicated by a single reader and by a second reader for intra- and inter-reader analysis (Circle Cardiovascular Imaging). Reliability was tested with intraclass correlation (ICC) tests, and the impact of imaging confounders on agreement was assessed through multivariable analysis. RESULTS: Left and right ventricular ejection fractions were reduced in 34% and 37% of the patients, respectively. Good to excellent reliability was shown for 2D (all ICC > 0.85) and 3D (all ICC > 0.70) peak strain and early diastolic strain rate for both ventricles in longitudinal orientation as well as circumferential orientations for the left ventricle. An increased slice number improved agreement while the presence of pericardial effusion compromised diastolic strain rate agreement, and arrhythmia compromised right ventricular agreement. CONCLUSION: In a large clinical cohort, we could show CMR-FT yields excellent inter-reader and intra-reader reproducibility. Multi-parametric CMR-FT of the right and left ventricles appears to be a robust tool in cardiovascular patients referred to CMR. CLINICALTRIALS: gov Identifier: NCT03470571, NCT04774549. Key Points • Cardiovascular magnetic resonance feature tracking (CMR-FT) is an emerging technique to measure myocardial strain in cardiovascular patients referred for CMR; however, the evaluation of its reproducibility in a large cohort has not yet been performed. • In a large clinical cohort, CMR-FT yields excellent inter-reader and intra-reader reproducibility for both left and right ventricular systolic and diastolic parameters. • Arrhythmia and pericardial effusion compromise agreement of select FT parameters, but poor ejection fraction does not.


Assuntos
Miocardite , Derrame Pericárdico , Humanos , Imagem Cinética por Ressonância Magnética/métodos , Miocardite/diagnóstico por imagem , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Função Ventricular Esquerda
9.
J Vasc Interv Radiol ; 33(4): 416-419.e2, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35365284

RESUMO

The purpose of this study was to define relevant intercostal artery (ICA) anatomy potentially impacting the safety of thoracic percutaneous interventional procedures. An ICA abutting the upper rib and running in the subcostal groove was defined as the lowest risk zone for interventions requiring a supracostal needle puncture. A theoretical high-risk zone was defined by the ICA coursing in the lower half of the intercostal space (ICS), and a theoretical moderate-risk zone was defined by the ICA coursing below the subcostal groove but in the upper half of the ICS. Arterial phase computed tomography data from 250 patients were analyzed, revealing demographic variability, with high-risk zones extending more laterally with advancing age and with more cranial ribs. Overall, within the 97.5th percentile, an ICS puncture >7-cm lateral to the spinous process incurs moderate risk and >10-cm lateral incurs the lowest risk.


Assuntos
Costelas , Parede Torácica , Artérias/anatomia & histologia , Artérias/diagnóstico por imagem , Humanos , Punções , Costelas/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos
10.
Europace ; 24(9): 1441-1450, 2022 10 13.
Artigo em Inglês | MEDLINE | ID: mdl-35253840

RESUMO

AIMS: No studies have compared Watchman 2.5 (W2.5) with Watchman FLX (FLX) devices to date. We aimed at comparing the FLX with W2.5 devices with respect to clinical outcomes, left atrial appendage (LAA) sealing properties and device-related thrombus (DRT). METHODS AND RESULTS: All consecutive left atrial appendage closure (LAAC) procedures performed at two European centres between November 2017 and February 2021 were included. Procedure-related complications and net adverse cardiovascular events (NACE) at 6 months after LAAC were recorded. At 45-day computed tomography (CT) follow-up, intra- (IDL) and peri- (PDL) device leak, residual patent neck area (RPNA), and DRT were assessed by a Corelab. Out of 144 LAAC consecutive procedures, 71 and 73 interventions were performed using W2.5 and FLX devices, respectively. There were no differences in terms of procedure-related complications (4.2% vs. 2.7%, P = 0.626). At 45-day CT, the FLX was associated with lower frequency of IDL [21.3% vs. 40.0%; P = 0.032; odds ratio (OR): 0.375; 95% confidence interval (CI): 0.160-0.876; P = 0.024], similar rate of PDL (29.5% vs. 42.0%; P = 0.170), and smaller RPNA [6 (0-36) vs. 40 (6-115) mm2; P = 0.001; OR: 0.240; 95% CI: 0.100-0.577; P = 0.001] compared with the W2.5 group. At 45 days, rate of DRT as detected by CT and/or transoesophageal echocardiography (TOE), was higher with W2.5 (6.0% vs. 0%, P = 0.045). At 6-month follow-up, NACE did not differ between groups. CONCLUSIONS: In this cohort of consecutive LAACs, FLX as compared to W2.5, was associated with similar procedure-related complications and 6-month NACE, but with improved LAA neck coverage, and lower IDL and DRT.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Dispositivo para Oclusão Septal , Acidente Vascular Cerebral , Trombose , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Cateterismo Cardíaco/efeitos adversos , Ecocardiografia Transesofagiana , Humanos , Dispositivo para Oclusão Septal/efeitos adversos , Acidente Vascular Cerebral/complicações , Acidente Vascular Cerebral/prevenção & controle , Trombose/etiologia , Trombose/prevenção & controle , Resultado do Tratamento
11.
BMC Cardiovasc Disord ; 22(1): 178, 2022 04 18.
Artigo em Inglês | MEDLINE | ID: mdl-35436856

RESUMO

BACKGROUND: Computed tomography angiography (CTA) is a cornerstone in the pre- transcatheter aortic valve replacement (TAVI) assessment. We evaluated the diagnostic performance of CTA and coronary artery calcium score (CACS) for CAD evaluation compared to invasive coronary angiography in a cohort of TAVI patients. METHODS: In consecutive TAVI patients without prior coronary revascularization and device implants, CAD was assessment by quantitative analysis in CTA. (a) Patients with non-evaluable segments were classified as obstructive CAD. (b) In patients with non-evaluable segments a CACS cut-off of 100 was applied for obstructive CAD. The reference standard was quantitative invasive coronary angiography (QCA, i.e. ≥ 50% stenosis). RESULTS: 100 consecutive patients were retrospectively included, age was 82.3 ± 6.5 years and 30% of patients had CAD. In 16% of the patients, adequate visualization of the entire coronary tree (all 16 segments) was possible with CTA, while 84% had at least one segment which was not evaluable for CAD analysis due to impaired image quality. On a per-patient analysis, where patients with low image quality were classified as CAD, CTA showed a sensitivity of 100% (95% CI 88.4-100.0), specificity of 11.4% (95% CI 5.1-21.3), PPV of 32.6% (95% CI 30.8-34.5), NPV of 100% and diagnostic accuracy of 38% (95% CI 28.5-48.3) for obstructive CAD. When applying a combined approach of CTA (in patients with good image quality) and CACS (in patients with low image quality), the sensitivity and NPV remained at 100% and obstructive CAD could be ruled out in 20% of the TAVI patients, versus 8% using CTA alone. CONCLUSION: In routinely acquired pre-TAVI CTA, the image quality was insufficient in a high proportion of patients for the assessment of the entire coronary artery tree. However, when adding CACS in patients with low image quality to quantitative CTA assessment in patients with good image quality, obstructive CAD could be ruled-out in 1/5 of the patients and may therefore constitute a strategy to streamline pre-procedural workup, and reduce risk, radiation and costs in selected TAVI patients without prior coronary revascularization or device implants.


Assuntos
Estenose da Valva Aórtica , Doença da Artéria Coronariana , Estenose Coronária , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Humanos , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/efeitos adversos
12.
Medicina (Kaunas) ; 59(1)2022 Dec 23.
Artigo em Inglês | MEDLINE | ID: mdl-36676651

RESUMO

Background and Objectives: Osteoarthritis (OA) of the knee is a degenerative disorder characterized by damage to the joint cartilage, pain, swelling, and walking disability. The purpose of this study was to assess whether demographic and radiologic parameters (knee diameters and knee cross-sectional area from magnetic resonance (MR) images) could be used as surrogate biomarkers for the prediction of OA. Materials and Methods: The knee diameters and cross-sectional areas of 481 patients were measured on knee MR images, and the corresponding demographic parameters were extracted from the patients' clinical records. The images were graded based on the modified Outerbridge arthroscopic classification that was used as ground truth. Receiver-operating characteristic (ROC) analysis was performed on the collected data. Results: ROC analysis established that age was the most accurate predictor of severe knee cartilage degeneration (corresponding to Outerbridge grades 3 and 4) with an area under the curve (AUC) of the specificity-sensitivity plot of 0.865 ± 0.02. An age over 41 years was associated with a sensitivity and specificity for severe degeneration of 82.8% (CI: 77.5-87.3%), and 76.4% (CI: 70.4-81.6%), respectively. The second-best degeneration predictor was the normalized knee cross-sectional area, with an AUC of 0.767 ± 0.04), followed by BMI (AUC = 0.739 ± 0.02), and normalized knee maximal diameter (AUC = 0.724 ± 0.05), meaning that knee degeneration increases with increasing knee diameter. Conclusions: Age is the best predictor of knee damage progression in OA and can be used as surrogate marker for knee degeneration. Knee diameters and cross-sectional area also correlate with the extent of cartilage lesions. Though less-accurate predictors of damage progression than age, they have predictive value and are therefore easily available surrogate markers of OA that can be used also by general practitioners and orthopedic surgeons.


Assuntos
Doenças das Cartilagens , Cartilagem Articular , Osteoartrite do Joelho , Humanos , Adulto , Osteoartrite do Joelho/diagnóstico por imagem , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Imageamento por Ressonância Magnética/métodos , Biomarcadores , Doenças das Cartilagens/diagnóstico por imagem , Doenças das Cartilagens/patologia , Cartilagem Articular/diagnóstico por imagem , Cartilagem Articular/patologia
13.
Eur Radiol ; 29(10): 5139-5147, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30847587

RESUMO

OBJECTIVES: To compare the performance of magnetic resonance (MR) relaxometry parameters to discriminate myocardial and skeletal muscle inflammation in idiopathic inflammatory myopathy (IIM) patients from healthy controls. MATERIALS AND METHODS: For this retrospective case-control study, 20 consecutive IIM patients (54 ± 18 years, 11 females) with cardiac involvement (troponin level > 50 ng/l) and 20 healthy controls (47 ± 12 years, 9 females) were included. All patients without cardiac MR imaging < 2 weeks prior to the laboratory testings were excluded. T1/T2 relaxation times, as well as T1-derived extracellular volume (ECV), relative tissue T1 shortening ΔT1 = (native T1tissue-post contrast T1tissue)/native T1tissue), and enhancement fraction EHF = (native T1tissue-post contrast T1tissue)/(native T1blood-post contrast T1blood), were compared using Mann-Whitney U test and ROC analysis. RESULTS: All measured MR relaxometry parameters significantly discriminated IIM patients and healthy controls, except T2 in skeletal muscles and ECV in the myocardium. In skeletal muscles, post contrast T1 and T1-derived parameters showed the best performance to discriminate IIM patients from healthy controls (AUC = 0.98 for post contrast T1 and AUC 0.94-0.97 for T1-derived parameters). Inversely, in the myocardium, native T1 and T2 showed better diagnostic performance (AUC = 0.89) than post contrast T1 (AUC = 0.76), ECV (AUC = 0.58), ΔT1 (AUC = 0.80) and EHF (0.82). CONCLUSIONS: MR relaxometry parameters applied to the myocardium and skeletal muscles might be useful to separate IIM patients from healthy controls. However, different tissue composition and vascularization should be taken into account for their interpretation. ΔT1 and EHF may be simple alternatives to ECV in highly vascularized tissues such as the myocardium. KEY POINTS: • MR relaxometry parameters applied to the myocardium and skeletal muscles are highly useful to separate IIM patients from healthy controls. • Different tissue composition and vascularization should be taken into account for T1 and T2 mapping parameter interpretation. • ΔT1 and EHF may be simple alternatives to ECV in highly vascularized tissues such as the myocardium.


Assuntos
Imagem Cinética por Ressonância Magnética/métodos , Músculo Esquelético/patologia , Miocárdio/patologia , Miosite/diagnóstico , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Curva ROC , Estudos Retrospectivos
14.
Radiology ; 286(1): 83-92, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-28813234

RESUMO

Purpose To determine whether left atrial (LA) strain quantification with cardiac magnetic resonance (MR) imaging feature tracking is associated with the severity of LA fibrofatty myocardial remodeling at histologic analysis. Materials and Methods This prospective case-control study was approved by the institutional review board. LA strain was evaluated with cardiac MR feature tracking between January 2014 and March 2015 in 13 consecutive patients (mean age, 61 years ± 19; nine male) with mitral regurgitation in the 24 hours before mitral valve surgery and 13 age- and sex-matched healthy control subjects. LA strain parameters were compared first between control subjects and patients and then according to atrial fibrillation and mitral regurgitation status. Associations between LA strain and histology of preoperative biopsies were reported by using receiver operating characteristic curve analysis and Spearman correlation. Results Peak longitudinal atrial strain (PLAS) was significantly lower in patients with mitral regurgitation than in healthy control subjects (P < .001). Increased LA remodeling was significantly related to altered LA strain, and the strongest association was found between PLAS and the degree of fibrofatty myocardial replacement at histologic analysis (r = -0.75, P = .017). LA end-diastolic volume was increased in patients with mitral regurgitation when compared with that in healthy volunteers (P < .001) because of volume overload; however, volume did not correlate with the histologic degree of LA fibrofatty replacement (r = -0.35, P = .330). Conclusion LA strain, especially PLAS, correlates strongly with the degree of fibrofatty replacement at histologic analysis. Such functional imaging biomarker in combination with LA volumetry could help to guide clinical decisions, since myocardial structural remodeling is a known morphologic substrate of LA dysfunction leading to atrial fibrillation with adverse outcome. © RSNA, 2017 Online supplemental material is available for this article.


Assuntos
Tecido Adiposo/diagnóstico por imagem , Remodelamento Atrial , Átrios do Coração/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética/métodos , Tecido Adiposo/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Feminino , Fibrose/diagnóstico por imagem , Fibrose/patologia , Átrios do Coração/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/patologia , Estudos Prospectivos
16.
J Cardiovasc Magn Reson ; 20(1): 11, 2018 02 12.
Artigo em Inglês | MEDLINE | ID: mdl-29429407

RESUMO

BACKGROUND: Idiopathic inflammatory myopathy (IIM) is a group of autoimmune diseases with systemic myositis which may involve the myocardium. Cardiac involvement in IIM, although often subclinical, may mimic clinical manifestations of acute viral myocarditis (AVM). Our aim was to investigate the usefulness of the combined analysis of cardiovascular magnetic resonance (CMR) T1 and T2 mapping parameters measured both in the myocardium and in the thoracic skeletal muscles to differentiate AVM from IIM cardiac involvement. METHODS: Sixty subjects were included in this retrospective study (36 male, age 45 ± 16 years): twenty patients with AVM, twenty patients with IIM and cardiac involvement and twenty healthy controls. Study participants underwent CMR imaging with modified Look-Locker inversion-recovery (MOLLI) T1 mapping and 3-point balanced steady-state-free precession T2 mapping. Relaxation times were quantified after endocardial and epicardial delineation on basal and medial short-axis slices, as well as in different thoracic skeletal muscle groups present in the CMR field-of-view. ROC-Analysis was performed to assess the ability of mapping indices to discriminate the study groups. RESULTS: Mapping parameters in the thoracic skeletal muscles were able to discriminate between AVM and IIM patients. Best skeletal muscle parameters to identify IIM from AVM patients were reduced post-contrast T1 and increased extracellular volume (ECV), resulting in an area under the ROC curve (AUC) of 0.95 for post-contrast T1 and 0.96 for ECV. Conversely, myocardial mapping parameters did not discriminate IIM from AVM patients but increased native T1 (AUC 0.89 for AVM; 0.84 for IIM) and increased T2 (AUC 0.82 for AVM; 0.88 for IIM) could differentiate both patient groups from healthy controls. CONCLUSION: CMR myocardial mapping detects cardiac inflammation in AVM and IIM compared to normal myocardium in healthy controls but does not differentiate IIM from AVM. However, thoracic skeletal muscle mapping was able to accurately discern IIM from AVM.


Assuntos
Coração/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética , Músculo Esquelético/diagnóstico por imagem , Miocardite/diagnóstico por imagem , Miosite/diagnóstico por imagem , Adulto , Idoso , Diagnóstico Diferencial , Feminino , Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Músculo Esquelético/fisiopatologia , Miocardite/fisiopatologia , Miocardite/virologia , Miosite/fisiopatologia , Valor Preditivo dos Testes , Estudos Retrospectivos , Tórax , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa