Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Histopathology ; 69(2): 177-86, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27196116

RESUMO

A new approach to the management of non-small-cell lung cancer (NSCLC) has recently emerged that works by manipulating the immune checkpoint controlled by programmed death receptor 1 (PD-1) and its ligand programmed death ligand 1 (PD-L1). Several drugs targeting PD-1 (pembrolizumab and nivolumab) or PD-L1 (atezolizumab, durvalumab, and avelumab) have been approved or are in the late stages of development. Inevitably, the introduction of these drugs will put pressure on healthcare systems, and there is a need to stratify patients to identify those who are most likely to benefit from such treatment. There is evidence that responsiveness to PD-1 inhibitors may be predicted by expression of PD-L1 on neoplastic cells. Hence, there is considerable interest in using PD-L1 immunohistochemical staining to guide the use of PD-1-targeted treatments in patients with NSCLC. This article reviews the current knowledge about PD-L1 testing, and identifies current research requirements. Key factors to consider include the source and timing of sample collection, pre-analytical steps (sample tracking, fixation, tissue processing, sectioning, and tissue prioritization), analytical decisions (choice of biomarker assay/kit and automated staining platform, with verification of standardized assays or validation of laboratory-devised techniques, internal and external quality assurance, and audit), and reporting and interpretation of the results. This review addresses the need for integration of PD-L1 immunohistochemistry with other tests as part of locally agreed pathways and protocols. There remain areas of uncertainty, and guidance should be updated regularly as new information becomes available.


Assuntos
Antineoplásicos/uso terapêutico , Antígeno B7-H1/metabolismo , Biomarcadores Tumorais/metabolismo , Carcinoma Pulmonar de Células não Pequenas/diagnóstico , Neoplasias Pulmonares/diagnóstico , Anticorpos Monoclonais/uso terapêutico , Anticorpos Monoclonais Humanizados/uso terapêutico , Antígeno B7-H1/efeitos dos fármacos , Carcinoma Pulmonar de Células não Pequenas/tratamento farmacológico , Carcinoma Pulmonar de Células não Pequenas/metabolismo , Humanos , Imuno-Histoquímica , Neoplasias Pulmonares/tratamento farmacológico , Neoplasias Pulmonares/metabolismo , Nivolumabe , Receptor de Morte Celular Programada 1/efeitos dos fármacos , Receptor de Morte Celular Programada 1/metabolismo , Controle de Qualidade
2.
Histopathology ; 56(3): 297-304, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20459530

RESUMO

AIM: To assess a new HER2 fluorescence in situ hybridization (FISH) test and report on multicentre intrasite and intersite variation. METHODS AND RESULTS: HER2 results were scored from 45 breast cancers in eight laboratories using the Kreatech Poseidon HER2 FISH probe (Kreatech Diagnostics, Amsterdam, the Netherlands). Overall, 80.9% of cores were successfully analysed. Mean intrasite variation for HER2 ratio assessment was low (4.74%). Intersite variation in ratio was in line with previous reports (11.9+/-0.8%) for both reference and non-reference laboratories; only one laboratory displayed significantly higher intersite variation (P=0.009) than the remaining seven laboratories. The overall incidence of misclassification of cores was <1.3%, demonstrating an excellent level of concordance (>98.7%) across all eight laboratories, irrespective of whether they were 'reference' or 'routine diagnostic' laboratories. CONCLUSIONS: The Kreatech Poseidon HER2 FISH test is robust and reproducible. Highly quantitatively reproducible FISH results were obtained from eight 'diagnostic' and 'reference' laboratories; however, continued quality assessments are essential to good performance.


Assuntos
Neoplasias da Mama/genética , Perfilação da Expressão Gênica/normas , Genes erbB-2 , Hibridização in Situ Fluorescente/normas , Patologia Clínica/normas , Feminino , Perfilação da Expressão Gênica/métodos , Humanos , Hibridização in Situ Fluorescente/métodos , Patologia Clínica/métodos , Reprodutibilidade dos Testes , Análise Serial de Tecidos , Reino Unido
3.
Am J Clin Pathol ; 129(3): 398-409, 2008 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-18285262

RESUMO

This study focused on recent assessment results from the United Kingdom National External Quality Assessment Scheme for Immunocytochemistry and Fluorescence In-Situ Hybridisation breast hormone receptor module in which participants were asked to demonstrate progesterone receptors (PRs). The slides consisted of 3 infiltrating ductal breast carcinomas, previously classified as a high PR expresser, a moderate to low PR expresser, and a negative tumor. During this assessment, 2 commercial rabbit monoclonal antibodies, SP2 (Lab Vision/NeoMarkers, Fremont, CA), and 1E2 (Ventana, Tucson, AZ) were used by 15% of the participants. The SP2 rabbit monoclonal antibody showed false-positive and nonspecific staining on the previously established PR-tumor. This article highlights the necessity for all clinical laboratories to validate immunohistochemical methods and protocols when using newly marketed antibodies such as SP2; use composite tissue blocks with known levels of tumor expression such as a high, mid, and negative expression; and participate in internal and external quality assessment schemes, which can highlight potential technical issues in laboratory methods.


Assuntos
Anticorpos Monoclonais , Imuno-Histoquímica/normas , Laboratórios/normas , Patologia Clínica/normas , Garantia da Qualidade dos Cuidados de Saúde , Receptores de Progesterona/metabolismo , Animais , Neoplasias da Mama/metabolismo , Carcinoma Ductal de Mama/metabolismo , Reações Cruzadas , Reações Falso-Positivas , Feminino , Humanos , Coelhos , Receptores de Progesterona/imunologia , Reino Unido
4.
J Pathol Clin Res ; 4(4): 262-273, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-30066480

RESUMO

We describe a collated data set of results from clinical testing of breast cancers carried out between 2009 and 2016 in the United Kingdom and Republic of Ireland. More than 199 000 patient biomarker data sets, together with clinicopathological parameters were collected. Our analyses focused on human epidermal growth factor receptor-2 (HER2), oestrogen receptor (ER) and progesterone receptor (PR), with the aim of the study being to provide robust confirmatory evidence on known associations in these biomarkers and to uncover new data on previously undescribed or unconfirmed associations, thus strengthening the evidence-base in clinical breast cancer testing. Overall, 13.1% of tumours were HER2-positive; 10.6% in ER-positive tumours, and 25.5% in ER-negative tumours. Higher rates of HER2 positivity were significantly associated with patient age <56 years versus age ≥56 years, symptomatic versus screen-detected tumours, testing of involved axillary node versus primary breast cancer, invasive ductal carcinoma (not otherwise specified) versus other histological types, higher histological grade, increasing tumour size, increasing nodal involvement, ER-negative versus ER-positive tumour status, PR-negative versus PR-positive tumour status. Where ER status was known, 82.7% of tumours were ER-positive; 80.9% in women age <56 years, and 83.6% in those age ≥56 years (ER-positive cut-off ≥1.0% positive tumour cells or equivalent). Where PR status was known, 64.9% of tumours were PR-positive; 65.8% in women age <56 years, and 64.4% in women age ≥56 years (PR-positive cut off ≥10.0% or equivalent). These analyses of clinical test results provide contemporary benchmarking data for HER2, ER and PR positive rates.


Assuntos
Biomarcadores Tumorais/metabolismo , Neoplasias da Mama/diagnóstico , Receptor alfa de Estrogênio/metabolismo , Receptor ErbB-2/metabolismo , Receptores de Progesterona/metabolismo , Biomarcadores Tumorais/genética , Neoplasias da Mama/genética , Neoplasias da Mama/metabolismo , Neoplasias da Mama/patologia , Bases de Dados Factuais , Receptor alfa de Estrogênio/genética , Feminino , Humanos , Imuno-Histoquímica , Hibridização In Situ , Irlanda , Receptor ErbB-2/genética , Receptores de Progesterona/genética , Reino Unido
5.
J Clin Pathol ; 60(7): 816-9, 2007 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-16963466

RESUMO

BACKGROUND AND AIMS: Trastuzumab provides clinical benefit for advanced and early breast cancer patients whose tumours over-express or have gene amplification of the HER2 oncogene. The UK National External Quality Assessment Scheme (NEQAS) for immunohistochemical testing was established to assess and improve the quality of HER2 immunohistochemical testing. However, until recently, no provision was available for HER2 fluorescence in situ hybridisation (FISH) testing. A pilot scheme was set up to review the performance of FISH testing in clinical diagnostic laboratories. METHODS: FISH was performed in 6 reference and 31 participating laboratories using a cell line panel with known HER2 status. RESULTS: Using results from reference laboratories as a criterion for acceptable performance, 60% of all results returned by participants were appropriate and 78% either appropriate or acceptable. However, 22.4% of results returned were deemed inappropriate, including 13 cases (4.2%) where a misdiagnosis would have been made had these been clinical specimens. CONCLUSIONS: The results of three consecutive runs show that both reference laboratories and a proportion of routine clinical diagnostic (about 25%) centres can consistently achieve acceptable quality control of HER2 testing. Data from a significant proportion of participating laboratories show that further steps are required, including those taken via review of performance under schemes such as NEQAS, to improve quality of HER2 testing by FISH in the "real world".


Assuntos
Biomarcadores Tumorais/metabolismo , Neoplasias da Mama/metabolismo , Hibridização in Situ Fluorescente/normas , Garantia da Qualidade dos Cuidados de Saúde/métodos , Receptor ErbB-2/metabolismo , Feminino , Pesquisa sobre Serviços de Saúde , Humanos , Laboratórios/normas , Projetos Piloto , Células Tumorais Cultivadas , Reino Unido
6.
Appl Immunohistochem Mol Morphol ; 25(2): 79-85, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-28182587

RESUMO

All laboratory tests have test performance characteristics (TPCs), whether or not they are explicitly known to the laboratorian or the pathologist. TPCs are thus also an integral characteristic of immunohistochemistry (IHC) tests and other in situ, cell-based molecular assays such as DNA or RNA in situ hybridization or aptamer-based testing. Because of their descriptive, in situ, cell-based nature, IHC tests have a limited repertoire of appropriate TPCs. Although only a few TPCs are relevant to IHC, proper selection of informative TPCs is nonetheless essential for the development of and adherence to appropriate quality assurance measures in the IHC laboratory. This paper describes the TPCs that are relevant to IHC testing and emphasizes the role of TPCs in the validation of IHC tests. This is part 2 of the 4-part series "Evolution of Quality Assurance for Clinical Immunohistochemistry in the Era of Precision Medicine."


Assuntos
Imuno-Histoquímica/normas , Medicina de Precisão , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
7.
Appl Immunohistochem Mol Morphol ; 25(4): 227-230, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-27941560

RESUMO

The numbers of diagnostic, prognostic, and predictive immunohistochemistry (IHC) tests are increasing; the implementation and validation of new IHC tests, revalidation of existing tests, as well as the on-going need for daily quality assurance monitoring present significant challenges to clinical laboratories. There is a need for proper quality tools, specifically tissue tools that will enable laboratories to successfully carry out these processes. This paper clarifies, through the lens of laboratory tissue tools, how validation, verification, and revalidation of IHC tests can be performed in order to develop and maintain high quality "fit-for-purpose" IHC testing in the era of precision medicine. This is the final part of the 4-part series "Evolution of Quality Assurance for Clinical Immunohistochemistry in the Era of Precision Medicine."


Assuntos
Imuno-Histoquímica/métodos , Laboratórios , Garantia da Qualidade dos Cuidados de Saúde , Técnicas de Laboratório Clínico , Humanos , Imuno-Histoquímica/instrumentação , Medicina de Precisão
8.
Appl Immunohistochem Mol Morphol ; 25(1): 4-11, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27922482

RESUMO

Technical progress in immunohistochemistry (IHC) as well as the increased utility of IHC for biomarker testing in precision medicine avails us of the opportunity to reassess clinical IHC as a laboratory test and its proper characterization as a special type of immunoassay. IHC, as used in current clinical applications, is a descriptive, qualitative, cell-based, usually nonlinear, in situ protein immunoassay, for which the readout of the results is principally performed by pathologists rather than by the instruments on which the immunoassay is performed. This modus operandi is in contrast to other assays where the instrument also performs the readout of the test result (eg, nephelometry readers, mass spectrometry readers, etc.). The readouts (results) of IHC tests are used either by pathologists for diagnostic purposes or by treating physicians (eg, oncologists) for patient management decisions, the need for further testing, or follow-up. This paper highlights the distinction between the original purpose for which an IHC test is developed and its subsequent clinical uses, as well as the role of pathologists in the analytical and postanalytical phases of IHC testing. This paper is the first of a 4-part series, under the general title of "Evolution of Quality Assurance for Clinical Immunohistochemistry in the Era of Precision Medicine."


Assuntos
Biomarcadores/metabolismo , Medicina de Precisão , Humanos , Imuno-Histoquímica , Hibridização in Situ Fluorescente
9.
Appl Immunohistochem Mol Morphol ; 25(3): 151-159, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-28187030

RESUMO

Validation of immunohistochemistry (IHC) assays is a subject that is of great importance to clinical practice as well as basic research and clinical trials. When applied to clinical practice and focused on patient safety, validation of IHC assays creates objective evidence that IHC assays used for patient care are "fit-for-purpose." Validation of IHC assays needs to be properly informed by and modeled to assess the purpose of the IHC assay, which will further determine what sphere of validation is required, as well as the scope, type, and tier of technical validation. These concepts will be defined in this review, part 3 of the 4-part series "Evolution of Quality Assurance for Clinical Immunohistochemistry in the Era of Precision Medicine."


Assuntos
Laboratórios/normas , Medicina de Precisão , Controle de Qualidade , Imuno-Histoquímica
10.
J Thorac Oncol ; 11(12): 2241-2247, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27468935

RESUMO

INTRODUCTION: Diagnostic immunohistochemistry (IHC) is increasingly accepted as a screening method for anaplastic lymphoma receptor tyrosine kinase gene (ALK) rearrangements in NSCLC. We have sought to establish an ongoing robust external quality assessment process to gauge quality of anaplastic lymphoma kinase (ALK) IHC, which can have an impact on interpretation of patient samples. METHODS: Unstained tissue and cell line samples were distributed on a quarterly basis to participating laboratories from 30 countries. Participants stained the slide using their routine diagnostic ALK IHC method and returned the slide along with their in-house control and methodology details. Slides were assessed by a team of pathologists and scientists. RESULTS: Overall, there was a mean pass rate of 83% (range 71%-98%), with 38 variations in staining protocol. Methods included the following: the Roche D5F3 assay (65% of users, pass rate 93%); Novocastra 5A4 (15% of users, pass rate 65%); Cell Signaling Technology D5F3 (7% of users, pass rate 91%), and Dako ALK1 (5% of users, pass rate 50%). Choice of methodology directly affected final interpretation of distributed ALK-positive and ALK-negative NSCLC cases, which were correctly identified by 89% and 88% of participants, respectively. Antibody detection method was a contributing factor in false-negative staining results. The choice of laboratory controls was found to be unsuitable, and as such, in-house control recommendations are also provided. CONCLUSIONS: ALK IHC is a robust screening technique, but there is concern that some diagnostic laboratories are using inadequate staining methods, which has a direct impact on final interpretation. External assessment helps provide laboratories with continued confidence in their ALK IHC testing.


Assuntos
Imuno-Histoquímica/métodos , Receptores Proteína Tirosina Quinases/imunologia , Quinase do Linfoma Anaplásico , Humanos
11.
J Clin Pathol ; 68(2): 93-9, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25488926

RESUMO

Human epidermal growth factor receptor 2 (HER2) overexpression is present in approximately 15% of early invasive breast cancers, and is an important predictive and prognostic marker. The substantial benefits achieved with anti-HER2 targeted therapies in patients with HER2-positive breast cancer have emphasised the need for accurate assessment of HER2 status. Current data indicate that HER2 test accuracy improved following previous publication of guidelines and the implementation of an external quality assessment scheme with a decline in false-positive and false-negative rates. This paper provides an update of the guidelines for HER2 testing in the UK. The aim is to further improve the analytical validity and clinical utility of HER2 testing by providing guidelines of test performance parameters, and recommendations on the postanalytical interpretation of test results. HER2 status should be determined in all newly diagnosed and recurrent breast cancers. Testing involves immunohistochemistry with >10% complete strong membrane staining defining a positive status. In situ hybridisation, either fluorescent or bright field chromogenic, is used either upfront or in immunohistochemistry borderline cases to detect the presence of HER2 gene amplification. Situations where repeat HER2 testing is advised are outlined and the impact of genetic heterogeneity is discussed. Strict quality control and external quality assurance of validated assays are essential. Testing laboratories should perform ongoing competency assessment and proficiency tests and ensure the reliability and accuracy of the assay. Pathologists, oncologists and surgeons involved in test interpretation and clinical use should adhere to published guidelines and maintain accurate performance and consistent interpretation of test results.


Assuntos
Biomarcadores Tumorais/análise , Neoplasias da Mama/enzimologia , Imuno-Histoquímica/normas , Hibridização In Situ/normas , Receptor ErbB-2/análise , Antineoplásicos/uso terapêutico , Benchmarking , Biomarcadores Tumorais/genética , Neoplasias da Mama/tratamento farmacológico , Neoplasias da Mama/genética , Neoplasias da Mama/patologia , Feminino , Regulação Neoplásica da Expressão Gênica , Humanos , Hibridização in Situ Fluorescente/normas , Terapia de Alvo Molecular , Seleção de Pacientes , Medicina de Precisão , Valor Preditivo dos Testes , Controle de Qualidade , Indicadores de Qualidade em Assistência à Saúde/normas , Receptor ErbB-2/antagonistas & inibidores , Receptor ErbB-2/genética , Manejo de Espécimes/normas , Reino Unido , Fluxo de Trabalho , Carga de Trabalho/normas
12.
Appl Immunohistochem Mol Morphol ; 23(1): 1-18, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25474126

RESUMO

Diagnostic immunohistochemistry (dIHC) has been practiced for several decades, with an ongoing expansion of applications for diagnostic use, and more recently for detection of prognostic and predictive biomarkers. However, standardization of practice has yet to be achieved, despite significant advances in methodology. An Ad Hoc Expert Committee was formed to address the standardization of controls, which is a missing link in demonstrating and assuring standardization of the various components of dIHC. This committee has also developed a concept of immunohistochemistry critical assay performance controls that are intended to facilitate methodology transfer and harmonization in dIHC. Furthermore, the committee has clarified definitions of IHC assay sensitivity and specificity, with special emphasis on how these definitions apply to positive controls. Recommendations for "best laboratory practice" regarding positive controls for dIHC are specified. The first set of immunohistochemistry critical assay performance controls for several frequently used IHC stains or tests is also developed and presented.


Assuntos
Comitês Consultivos , Imuno-Histoquímica/normas , Prova Pericial , Humanos , Imuno-Histoquímica/métodos , Cooperação Internacional , Guias de Prática Clínica como Assunto , Padrões de Referência , Sensibilidade e Especificidade
13.
Exp Toxicol Pathol ; 55(1): 59-68, 2003 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12940630

RESUMO

UNLABELLED: The effects of additional i.v. therapy with a cyclooxygenase-inhibitor Eltenac to a recombinant surfactant protein C (rSP-C) based surfactant were investigated in a rat lung lavage model of acute lung injury. Treatment was done at 60 min after the induction of acute lung injury by lavage. The influence of the different treatments were tested with regard to improving oxygenation, histopathological changes (hyaline membrane formation and alveolar influx of neutrophil leukocytes). These effects were further compared to a fixed combination of Eltenac with rSP-C surfactant which was administered intratracheally (i.tr.), 60 min after lavage. To prove that fibrinogen is involved in the formation of hyaline membranes in this animal model confocal microscopy was applied. Furthermore, for selected cases the influence of Eltenac or rSP-C surfactant on fibrinogen leakage was investigated by using confocal microscopy. Results of additional i.v. therapy exhibited an improved oxygenation with rSP-C surfactant, while a high dose of Eltenacalone did not influence oxygenation as compared to untreated controls. Addition of Eltenac lead to improved oxygenation using the low dose of rSP-C surfactant. The rSP-C surfactant prevented further hyaline membrane formation. Furthemore, addition of Eltenac to the low dose of rSP-C surfactant lead to improved hyaline membrane formation at a dose of 100 micromol/kg b.w. Results of combined i.tr. therapy confirmed the results of the additional therapy. Again, rSP-C surfactant improved oxygenation and further hyaline membrane formation, while even the high dose of i.tr. administered Eltenacalone only prevented further hyaline membrane formation. Using the low dose of rSP-C surfactant, combined treatment with Eltenac showed additional effects on oxygenation and inhibition of hyaline membrane formation. The maximum therapeutic effect of combined treatment was achieved at 0.3 mg Eltenac per kg b.w. which is equivalent to approximately 1 micromol. The inflammatory cell infiltration into the lung was not influenced by any of the therapeutic approaches. Confocal microscopy gave evidence that fibrinogen is involved in hyaline membrane formation in this animal model. Furthermore, as was shown by the explorative investigations with confocal microscopy, addition of the cyclooxygenase-inhibitor decreases the diffuse interstitial leakage of fibrinogen into the lung while surfactant monotherapy did not exhibit any influence on the fibrinogen influx into the alveoli. CONCLUSIONS: Confocal microscopy may be an effective method to investigate the connection between fibrinogen leakage and hyaline membrane formation. Effects of additional or combined treatment were superior when compared to each treatment alone leading to the conclusion that a rSP-C surfactant containing a cyclooxygenase-inhibitor, acts synergistically in this animal model of acute lung injury. Lower doses of Eltenac could be used to reach similar effects on oxygenation and prevention of hyaline membrane after combined i.tr. treatment than after additional i.v. treatment together with surfactant. This leads to the conclusion that a fixed combination of rSP-C surfactant and a cyclooxygenase-inhibitor may be an effective treatment. Further testing may be warranted to prove whether this is a promising treatment for patients with acute lung injury.


Assuntos
Compostos de Anilina/uso terapêutico , Inibidores de Ciclo-Oxigenase/uso terapêutico , Surfactantes Pulmonares/uso terapêutico , Síndrome do Desconforto Respiratório/tratamento farmacológico , Tiofenos/uso terapêutico , Doença Aguda , Compostos de Anilina/administração & dosagem , Animais , Gasometria , Lavagem Broncoalveolar/métodos , Inibidores de Ciclo-Oxigenase/administração & dosagem , Modelos Animais de Doenças , Relação Dose-Resposta a Droga , Sinergismo Farmacológico , Quimioterapia Combinada , Fibrinogênio/metabolismo , Injeções Intravenosas , Intubação Intratraqueal , Pulmão/efeitos dos fármacos , Pulmão/metabolismo , Masculino , Microscopia Confocal , Surfactantes Pulmonares/administração & dosagem , Ratos , Ratos Sprague-Dawley , Proteínas Recombinantes , Síndrome do Desconforto Respiratório/sangue , Tiofenos/administração & dosagem
14.
Appl Immunohistochem Mol Morphol ; 22(4): 241-52, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24714041

RESUMO

Standardization of controls, both positive and negative controls, is needed for diagnostic immunohistochemistry (dIHC). The use of IHC-negative controls, irrespective of type, although well established, is not standardized. As such, the relevance and applicability of negative controls continues to challenge both pathologists and laboratory budgets. Despite the clear theoretical notion that appropriate controls serve to demonstrate the sensitivity and specificity of the dIHC test, it remains unclear which types of positive and negative controls are applicable and/or useful in day-to-day clinical practice. There is a perceived need to provide "best practice recommendations" for the use of negative controls. This perception is driven not only by logistics and cost issues, but also by increased pressure for accurate IHC testing, especially when IHC is performed for predictive markers, the number of which is rising as personalized medicine continues to develop. Herein, an international ad hoc expert panel reviews classification of negative controls relevant to clinical practice, proposes standard terminology for negative controls, considers the total evidence of IHC specificity that is available to pathologists, and develops a set of recommendations for the use of negative controls in dIHC based on "fit-for-use" principles.


Assuntos
Biomarcadores Tumorais/análise , Imuno-Histoquímica/normas , Neoplasias/diagnóstico , Feminino , Humanos , Masculino , Neoplasias/patologia , Controle de Qualidade , Padrões de Referência , Sensibilidade e Especificidade , Terminologia como Assunto
15.
J Cancer Res Clin Oncol ; 139(9): 1563-8, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23892410

RESUMO

PURPOSE: Triple (ER-, PR-, HER2-) negative breast carcinoma lack targeted therapies, making this group of tumors difficult to treat. By definition, the lack of HER2 expression means a case scoring 0 or 1+ after immunophenotypical analysis and makes the patients avoiding therapeutical chances with anti-HER2 inhibitors. We sought to recruit from a group of triple negative breast carcinoma, patients eligible for effective personalized targeted therapy with anti-HER therapies on the basis of their HER2 gene status. METHODS: 135 patients diagnosed with IHC triple negative breast carcinoma were studied. Whole tissue sections were used for in situ hybridization analysis. RESULTS: 8/100 (8 %) of ductal-type triple negative breast carcinoma presented Her-2/neu gene amplification versus 2/35 (5.7 %) non-ductal triple negative breast carcinoma. Three cases showed a ratio 2.5. One case showed Her-2/neu heterogeneous gene amplification, ratio 2.3. The other six showed from 7 to 8 absolute Her-2/neu gene copy number. Two cases staged pT1c, and eight cases staged pT2. Eight cases graded G3 and two cases G2. CONCLUSION: (1) Eight percentage of ductal and 5.7 % non-ductal-type triple negative breast carcinoma present Her-2/neu gene amplification, (2) the standard diagnostic flowchart "do not FISH in 0-1+ (HER2-) breast carcinoma" should be replaced by "do FISH in triple (ER-, PR-, HER2-) negative breast carcinoma," to avoid loss of therapeutical chances in a cohort of such a patients, (3) we demonstrated the identification of a small but significant subset of patients targetable with anti-HER2 inhibitors, giving patients affected by (ex)triple negative breast carcinoma new personalized therapeutical chances.


Assuntos
Anticorpos Monoclonais Humanizados/uso terapêutico , Neoplasias da Mama/tratamento farmacológico , Carcinoma Ductal de Mama/tratamento farmacológico , Carcinoma de Células Escamosas/tratamento farmacológico , Receptor ErbB-2/antagonistas & inibidores , Receptores de Estrogênio/metabolismo , Receptores de Progesterona/metabolismo , Adulto , Idoso , Idoso de 80 Anos ou mais , Antineoplásicos/uso terapêutico , Glândulas Apócrinas/metabolismo , Glândulas Apócrinas/patologia , Neoplasias da Mama/metabolismo , Neoplasias da Mama/patologia , Carcinoma Ductal de Mama/metabolismo , Carcinoma Ductal de Mama/patologia , Carcinoma de Células Escamosas/metabolismo , Carcinoma de Células Escamosas/patologia , Estudos de Coortes , Feminino , Seguimentos , Amplificação de Genes , Humanos , Técnicas Imunoenzimáticas , Hibridização in Situ Fluorescente , Pessoa de Meia-Idade , Gradação de Tumores , Estadiamento de Neoplasias , Prognóstico , Receptor ErbB-2/genética , Receptor ErbB-2/metabolismo , Trastuzumab
16.
Am J Clin Pathol ; 135(1): 157-62, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21173138

RESUMO

We performed a multicenter assessment of a new HER2 dual-color chromogenic in situ hybridization (CISH) test and herein report on concordance of CISH data with fluorescence in situ hybridization (FISH) data and intraobserver and interlaboratory scoring consistency. HER2 results were evaluated using duplicate cores from 30 breast cancers in 5 laboratories using the Ventana HER2 dual-color ISH assay (Ventana Medical Systems, Cambridgeshire, England) and in 1 central laboratory using a standard FISH assay. Overall 93.3% of cases were successfully analyzed by CISH across the 5 participating laboratories. There was excellent concordance (98.0% overall) for diagnosis of HER2 amplification by CISH compared with FISH. Intraobserver variability (7.7%) and intersite variability (9.1%) of absolute HER2/chromosome enumeration probe 17 ratios were tightly controlled across all participating laboratories. The Ventana HER2 dual-color ISH assay is robust and reproducible, shows good concordance with a standard FISH assay, and complies with requirements in national and international guidelines for performance of ISH-based diagnostic tests.


Assuntos
Adenocarcinoma/genética , Neoplasias da Mama/genética , Hibridização in Situ Fluorescente/métodos , Receptor ErbB-2/genética , Adenocarcinoma/metabolismo , Neoplasias da Mama/metabolismo , Cromossomos Humanos Par 17 , Feminino , Perfilação da Expressão Gênica , Humanos , Patologia Clínica , Receptor ErbB-2/metabolismo , Análise Serial de Tecidos , Reino Unido
17.
J Clin Pathol ; 64(8): 649-53, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21690244

RESUMO

These guidelines supplement existing guidelines on HER2 testing by immunohistochemistry and in-situ hybridisation(ISH) methods in the UK. They provide a specific focus on aspects of guidance relevant to HER2 ISH testing methods, both fluorescent and chromogenic. They are formulated to give advice on methodology, interpretation and quality control for ISH-based testing of HER2 status in common tumour types, including both breast and gastric tumours. The aim is to ensure that all ISH-based testing is accurate, reliable and timely.


Assuntos
Neoplasias da Mama/diagnóstico , Hibridização In Situ/métodos , Receptor ErbB-2/metabolismo , Neoplasias Gástricas/diagnóstico , Neoplasias da Mama/genética , Feminino , Genes erbB-2 , Humanos , Hibridização In Situ/normas , Capacitação em Serviço , Corpo Clínico/educação , Técnicas de Sonda Molecular , Garantia da Qualidade dos Cuidados de Saúde , Controle de Qualidade , Projetos de Pesquisa , Manejo de Espécimes , Neoplasias Gástricas/genética
18.
Appl Immunohistochem Mol Morphol ; 17(6): 536-42, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19417622

RESUMO

The field of companion diagnostics is an expanding area in which industry can make significant contributions to the quality and reliability of prognostic and predictive assays. HER2 testing by immunohistochemistry and in situ hybridization, by virtue of its semi-quantitative nature demands the highest level of reagent quality and consistency. We describe a unique manufacturing practice that is used to guarantee the quality of control cell line slides provided for controlling the staining procedure and ensuring the validity of the reagent performance. An IHC control that could reflect variations in fixation, processing, section thickness, section storage and staining protocols would provide a useful tool for improved standardization. One way to ensure such accuracy and reproducibility of HER2 testing is by using robust internal controls. We intend to present for the first time, details of a unique manufacturing process, that of interferometry, the technique of using the pattern of interference created by the superposition of 2 or more waves to diagnose the properties of the aforementioned waves, that is, "section thickness," to guarantee the quality and consistency of internal cell line controls that can be used in a HER2 testing assay.


Assuntos
Imuno-Histoquímica/métodos , Interferometria/métodos , Glândulas Mamárias Humanas/patologia , Linhagem Celular , Humanos , Imuno-Histoquímica/instrumentação , Imuno-Histoquímica/normas , Interferometria/instrumentação , Interferometria/normas , Guias de Prática Clínica como Assunto , Controle de Qualidade , Receptor ErbB-2 , Padrões de Referência , Reprodutibilidade dos Testes
19.
Am J Clin Pathol ; 131(1): 106-11, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19095573

RESUMO

The American Society of Clinical Oncology/College of American Pathologists guidelines highlighted the critical importance of quality assurance in diagnostic testing for HER2. Unstained formalin-fixed, paraffin-embedded human breast carcinoma cell line sections were circulated to scheme participants on 9 occasions. "Reference laboratories" reported results for the HER2/chromosome 17 ratio and HER2 copy number for 3 years for each cell line, including 418 sets of results (1,671 results total). The number of participants was 62 laboratories in the final analysis. The mean and SD of results from reference laboratories demonstrated consistency during the 3-year period. The percentage of laboratories achieving "appropriate" results ranged from 45% to 88%, and the percentage achieving "inappropriate" results ranged from 5% to 29%. No consistent effect of the HER2 in situ hybridization testing method was demonstrated. Participation in external quality assurance schemes is a valuable mechanism for demonstrating and acquiring consistency for HER2 testing by in situ hybridization. Poor performance can be corrected via assistance and advice.


Assuntos
Receptor ErbB-2/análise , Humanos , Hibridização In Situ/métodos , Hibridização in Situ Fluorescente/métodos , Controle de Qualidade
20.
Am J Clin Pathol ; 132(4): 514-20, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19762528

RESUMO

Our purposes were to perform a robust assessment of a new HER2 chromogenic in situ hybridization test and report on concordance of silver in situ hybridization (SISH) data with fluorescence in situ hybridization (FISH) data and on intraobserver and interlaboratory scoring consistency. HER2 results were scored from 45 breast cancers in 7 laboratories using the Ventana (Tucson, AZ) INFORM HER-2 SISH assay and in 1 central laboratory using a standard FISH assay. Overall, 94.8% of cases were successfully analyzed by SISH across the 6 participating laboratories that reported data. Concordance for diagnosis of HER2 amplification by SISH compared with FISH was high (96.0% overall). Intraobserver variability (8.0%) and intersite variability (12.66%) of absolute HER2/chromosome 17 ratios appear to be tightly controlled across all 6 participating laboratories. The Ventana INFORM HER-2 SISH assay is robust and reproducible, shows good concordance with a standard FISH assay, and complies with requirements in national guidelines for performance of diagnostic tests.


Assuntos
Genes erbB-2 , Hibridização in Situ Fluorescente/métodos , Hibridização In Situ/métodos , Neoplasias da Mama/diagnóstico , Cromossomos Humanos Par 17 , Feminino , Humanos , Variações Dependentes do Observador , Receptor ErbB-2/análise , Reprodutibilidade dos Testes , Prata
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa