Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 102
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Int Ophthalmol ; 43(5): 1745-1749, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36418806

RESUMO

PURPOSE: To describe reoperations in the operating room for complications that occurred within the first 90 days after gel stent implantation or trabeculectomy at a single institution over 5 years. METHODS: In this retrospective chart review, patients who have undergone gel stent implantation with mitomycin C (MMC) or trabeculectomy with MMC were enrolled. Postoperative complications that required reoperations within the first 90 days were evaluated. RESULTS: A total of 510 surgeries were performed on 392 patients over a 57-month period by 2 glaucoma surgeons. Of these, 284 were gel stent implantation, and 226 were trabeculectomy. Combined phacoemulsification was performed in 52/284 (18.3%) in the gel stent group and in 26/226 (11.5%) of eyes in the trabeculectomy group (p = 0.03). Reoperations took place in 13/510 (2.5%) eyes, including 4/284 (1.4%) in the gel stent group, 9/226 (4.0%) in the trabeculectomy group (p = 0.07). In the gel stent group, indications for reoperation were bleb failure (2), suprachoroidal hemorrhage (1), bullous keratopathy (1). In the trabeculectomy group, indications for reoperation were bleb failure (3), overfiltration (2), persistent wound leak (2), aqueous misdirection (2). CONCLUSIONS: The rates of reoperation for early postoperative complications after gel stent or trabeculectomy was low and comparable with previous studies. A slightly higher number of reoperations within 90 days was observed in the trabeculectomy group than the gel stent group despite the more significant number of combined procedures in the latter group. Bleb failure was the most common indications for reoperation in both groups. Excessive outflow was a cause of reoperation mostly in the trabeculectomy group.


Assuntos
Glaucoma , Trabeculectomia , Humanos , Trabeculectomia/efeitos adversos , Trabeculectomia/métodos , Estudos Retrospectivos , Pressão Intraocular , Reoperação , Glaucoma/cirurgia , Mitomicina , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/cirurgia , Resultado do Tratamento
2.
Ophthalmic Res ; 65(4): 417-424, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34808615

RESUMO

INTRODUCTION: This study aimed to investigate the relationship between the choroidal circulation and glaucoma, assessing macular choroidal thickness (MCT) as a predictive value of glaucomatous visual field damage. METHODS: Twenty primary open-angle glaucoma patients were recruited. Patients underwent 2 SS-OCT scans: one with DRI OCT (Topcon) and the other with PLEX Elite 9000 (Zeiss). Standard OCT parameters were acquired by DRI OCT, while MCT was manually measured in 5 points on Plex ELITE 9000 images. The relationship among MCT, standard OCT parameters, and visual field indices was evaluated. Pearson's r correlation was calculated to evaluate these relationships. Reproducibility of measurements was analyzed. RESULTS: MCT measurements showed a good intra- and interobserver repeatability. A negative correlation appeared between MCT and BMI (r = -0.518, p = 0.023). Mean deviation showed a statistically significant correlation with MCT measured at subfoveal and at 1,000 µm nasally (r = 0.50, p = 0.03, and r = 0.52, p = 0.023). A correlation was found between the 2 MCT (Zeiss vs. Topcon) measurements and between MCT and peripapillary choroidal thickness (r = 0.944 and r = 0.740, p < 0.001, respectively). CONCLUSIONS: A good intra- and interobserver reproducibility was found. MCT showed a weak predictive value of glaucomatous visual field damage. A significant correlation was found between MCT and BMI.


Assuntos
Glaucoma de Ângulo Aberto , Glaucoma , Estudos Transversais , Glaucoma de Ângulo Aberto/diagnóstico , Humanos , Reprodutibilidade dos Testes , Tomografia de Coerência Óptica/métodos , Campos Visuais
4.
Int Ophthalmol ; 37(2): 417-421, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27324371

RESUMO

The purpose of this study was to evaluate the aqueous humor concentrations of bromfenac ophthalmic solution 0.09 % in patients undergoing phacoemulsification. Patients requiring cataract extraction received one drop (50 µL) of bromfenac 0.09 % solution in the eye to be operated, before bedtime the day before surgery or the morning of the surgery. The last administration was recorded. At the time of paracentesis, an aqueous humor sample was collected with a 30-gauge needle attached to a TB syringe and was later analyzed by high-performance liquid chromatography for drug concentration. 188 treated volunteers and 48 control, untreated, subjects were included in the study. The mean aqueous concentration of bromfenac in the treated group was 37.60 ± 68.86 and 0 nM (nmol/L) in the control group (p < 0.0001). Correlation coefficient in bromfenac group between time elapsed from instillation and drug concentration was -0.16 (p not significant). Bromfenac showed properties of good penetration and stable concentration in aqueous humor up to about 12 h after instillation.


Assuntos
Humor Aquoso/química , Benzofenonas/análise , Bromobenzenos/análise , Cromatografia Líquida de Alta Pressão/métodos , Idoso , Anti-Inflamatórios não Esteroides/administração & dosagem , Anti-Inflamatórios não Esteroides/análise , Anti-Inflamatórios não Esteroides/farmacocinética , Benzofenonas/administração & dosagem , Benzofenonas/farmacocinética , Bromobenzenos/administração & dosagem , Bromobenzenos/farmacocinética , Estudos de Casos e Controles , Feminino , Seguimentos , Humanos , Masculino , Soluções Oftálmicas/administração & dosagem , Soluções Oftálmicas/farmacocinética , Facoemulsificação , Cuidados Pré-Operatórios , Estudos Prospectivos , Fatores de Tempo
5.
Ophthalmic Res ; 56(2): 85-91, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27192975

RESUMO

PURPOSE: To evaluate macular ganglion cell layer (GCL) and ganglion cell-inner plexiform layer (GCIPL) thicknesses in patients with obstructive sleep apnea (OSA) syndrome. METHODS: 73 OSA patients and 67 age-matched controls were consecutively and prospectively enrolled. All participants underwent at least one reliable standard automated perimetry (SAP) and were imaged with spectral-domain optical coherence tomography (OCT) using two different devices. The OCT parameters were compared between groups, and Pearson correlations between main indices of SAP and OCT parameters were calculated. RESULTS: The pattern standard deviation of SAP was higher in the OSA group (p = 0.001). Mean GCIPL thickness was 82.99 ± 10.30 and 80.78 ± 12.15 µm in the control and OSA groups, respectively (p = 0.25), and GCL thickness was 44.93 ± 11.42 µm in the control group and 48.81 ± 10.85 µm in OSA individuals (p = 0.47). Pearson correlations between the GCIPL-GCL measurements and the main indices of SAP were not significant. CONCLUSIONS: Neither GCIPL nor GCL thickness were reduced in OSA subjects compared with healthy individuals. Retinal sensitivity evaluated with SAP was however decreased in OSA patients.


Assuntos
Fibras Nervosas/patologia , Doenças Retinianas/etiologia , Células Ganglionares da Retina/patologia , Apneia Obstrutiva do Sono/complicações , Tomografia de Coerência Óptica/métodos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Doenças Retinianas/diagnóstico , Apneia Obstrutiva do Sono/fisiopatologia
6.
Clin Lab ; 61(1-2): 47-52, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25807637

RESUMO

BACKGROUND: The aim of the study was to recreate in-vitro artificial aqueous humor with the same physico-chemical properties of human aqueous humor to be used as a standard matrix in chromatography to assess drug concentration in the anterior and posterior chamber of the human eye. METHODS: The artificial aqueous humor was prepared according to the human aqueous humor chemical compositions reported in the literature. The artificial matrix was then analysed via the HPLC-UV method and compared with aqueous humor from 15 patients who underwent cataract surgery. Known concentrations of widely-used ophthalmological drugs were added to the artificial aqueous humor in order to assess whether it can be used to explore ocular disposition towards topically or systemically administered drugs. RESULTS: No significant differences were found between the two examined aqueous humor types. There were no significant qualitative differences between examined fluids in terms of presence of ophthalmological drugs. CONCLUSIONS: The composition of artificial, in-vitro recreated aqueous humor was similar to that of the human kind. The absence of significant differences in the analysis of tested drugs both in the artificial and in human aqueous humor indicates that artificial aqueous humor may be used to generate a matrix-based standard curve for analytical method validation.


Assuntos
Humor Aquoso/química , Soluções Oftálmicas/análise , Preparações Farmacêuticas/análise , Idoso , Idoso de 80 Anos ou mais , Órgãos Artificiais , Disponibilidade Biológica , Cromatografia Líquida de Alta Pressão , Feminino , Humanos , Masculino , Farmacocinética
7.
Graefes Arch Clin Exp Ophthalmol ; 253(3): 425-30, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25398660

RESUMO

PURPOSE: Increased levels of oxidative stress have been seen in animal models of dry eye and in the conjunctival epithelial cells of patients with Sjögren's syndrome. The aims of this study were to compare the levels of oxidative stress in patients with dry eye and patients without dry eye and to evaluate the effects of treatment with preservative-free eye drops containing hyaluronic acid 0.15 % and vitamin B12 on oxidative stress and dry eye symptoms. METHODS: Three cohorts of patients who were to undergo planned cataract surgery were enrolled: patients with dry eye randomized to either no treatment (n = 29) or treatment (n = 32) with hyaluronic acid/vitamin B12 eye drops, and patients without dry eye (n = 42). Patients were assessed by Schirmer's type I test, fluorescein clearance test (FCT), Break Up Time (BUT), and Ocular Surface Disease Index (OSDI). Lipid peroxidation, a marker of oxidative stress, was assessed by LP-CHOLOX test. RESULTS: Compared with patients without dry eye, patients with dry eye had significantly increased levels of oxidative stress, higher OSDI and FCT scores, and significantly lower Schirmer's test and BUT scores. Treatment with eye drops containing hyaluronic acid 0.15 % and vitamin B12 was associated with significantly reduced levels of oxidative stress and OSDI and FCT scores and significantly increased Schirmer's test and BUT scores. CONCLUSIONS: These findings indicate that oxidative stress is associated with dry eye and that hyaluronic acid/vitamin B12 eye drops may attenuate oxidative stress and inflammation, improving dry eye symptoms. Further study in controlled clinical trials is warranted.


Assuntos
Túnica Conjuntiva/efeitos dos fármacos , Síndromes do Olho Seco/tratamento farmacológico , Ácido Hialurônico/administração & dosagem , Estresse Oxidativo/efeitos dos fármacos , Viscossuplementos/administração & dosagem , Vitamina B 12/administração & dosagem , Complexo Vitamínico B/administração & dosagem , Administração Tópica , Idoso , Túnica Conjuntiva/metabolismo , Combinação de Medicamentos , Síndromes do Olho Seco/metabolismo , Epitélio/efeitos dos fármacos , Epitélio/metabolismo , Feminino , Humanos , Peroxidação de Lipídeos , Masculino , Soluções Oftálmicas , Concentração Osmolar , Conservantes Farmacêuticos , Estudos Prospectivos , Lágrimas/química
8.
Ophthalmic Res ; 51(3): 146-52, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24557328

RESUMO

AIM: To investigate and compare the effects of topical benzalkonium chloride-preserved prostaglandins (PGAs) on the ocular surface in patients with primary open-angle glaucoma before and after 3 months of treatment with additional 0.5% preservative-free tamarind seed polysaccharide single-dose eyedrops (TSP®, Oftagen, Pisa, Italy). METHODS: This was a prospective, longitudinal, multicenter study. From 5 different Italian glaucoma centers, 10 glaucomatous patients were recruited in each center. All the patients were treated with a PGA with preservative for at least 1 year. Preservative-free artificial tears 3 times per day were prescribed. The participants were subjected to clinical and instrumental evaluation at baseline, after 1 month and after 3 months of treatment. All patients were examined with a digital corneal confocal laser scanning microscope (HRT II Rostock Cornea Module). RESULTS: After 3 months of TSP 0.5% treatment, an improvement of some ocular signs and symptoms was found. The percentage of conjunctival hyperemia decreased from 67 to 13%. Schirmer's test and breakup time significantly changed from the baseline after 3 months. Confocal microscopy showed a significant increase in conjunctival goblet cells. CONCLUSION: Artificial substitutes, in particular TSP 0.5%, might protect the ocular surface hence giving higher compliance, adherence and quality of life to the patients.


Assuntos
Glaucoma de Ângulo Aberto/tratamento farmacológico , Soluções Oftálmicas/uso terapêutico , Fitoterapia/métodos , Preparações de Plantas/uso terapêutico , Prostaglandinas/uso terapêutico , Tamarindus , Adulto , Idoso , Idoso de 80 Anos ou mais , Túnica Conjuntiva/irrigação sanguínea , Túnica Conjuntiva/efeitos dos fármacos , Córnea/efeitos dos fármacos , Feminino , Glaucoma de Ângulo Aberto/metabolismo , Glaucoma de Ângulo Aberto/patologia , Humanos , Hiperemia/patologia , Itália , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Lágrimas/metabolismo
9.
Eye (Lond) ; 38(10): 1903-1907, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38615097

RESUMO

PURPOSE: This study aims to investigate inter-image intra-observer variability of macular, and optic disc (ONH) microvasculature measurements of glaucomatous and normal subjects using Swept-Source Optical Coherence Tomography Angiography (OCT-A) (OCT Topcon ImageNet 6; DRI OCT Triton, Topcon Corporation, JAPAN) - based imaging data analysis and processing with a newly made quantitative approach. METHODS: A total of 20 glaucomatous and 20 healthy eyes underwent three OCT-A scanning of the ONH and macula. Macular and papillary and peripapillary vascular networks were calculated. For each eye, eighteen scans were analyzed using a novel approach: custom MATLAB 2021b scripts were employed for imaging analyses. Grayscale distribution was performed using the histcounts MATLAB function with 51 bins. For all layers, the vascular layer coefficient of variation (vl CoV) of the three measures were performed. The vl CoV difference between the two groups was analyzed by Student t-test. RESULTS: In glaucomatous eyes, the vl CoV ranged from 4.49% to 8.54%, while in the control group from 3.58% to 8.32%. Both groups exhibited higher CoVs when assessing the optic disc. The papillary and macular microvasculature reproducibility was comparable between groups. CONCLUSIONS: Utilizing Swept-Source OCT-A images our study has identified an easy and reproducible method that appears to be fast and can assist physicians in assessing macular and ONH perfusion with less inter-image variability, particularly in the 70 µm superficial area of the optic disc. The high reliability obtained suggested that this method could be useful as early clinical biomarker.


Assuntos
Angiofluoresceinografia , Variações Dependentes do Observador , Disco Óptico , Vasos Retinianos , Tomografia de Coerência Óptica , Humanos , Tomografia de Coerência Óptica/métodos , Disco Óptico/irrigação sanguínea , Disco Óptico/diagnóstico por imagem , Feminino , Masculino , Pessoa de Meia-Idade , Vasos Retinianos/diagnóstico por imagem , Vasos Retinianos/patologia , Angiofluoresceinografia/métodos , Idoso , Pressão Intraocular/fisiologia , Voluntários Saudáveis , Glaucoma/diagnóstico por imagem , Glaucoma/diagnóstico , Glaucoma/fisiopatologia , Reprodutibilidade dos Testes , Macula Lutea/diagnóstico por imagem , Macula Lutea/irrigação sanguínea , Macula Lutea/patologia , Glaucoma de Ângulo Aberto/diagnóstico por imagem , Glaucoma de Ângulo Aberto/fisiopatologia , Glaucoma de Ângulo Aberto/diagnóstico , Microvasos/diagnóstico por imagem , Microvasos/patologia , Adulto
10.
J Glaucoma ; 33(10): 715-727, 2024 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-39018018

RESUMO

PRCIS: We have developed through a consensus process 24 clinical recommendations for the comprehensive management of ocular surface inflammation in glaucoma patients, including diagnostic criteria, prevention measures, and treatment strategies according to ocular surface disease severity. PURPOSE: To obtain expert consensus on the diagnosis, prevention, and management of ocular surface inflammation (OSI) in patients with glaucoma. METHODS: An international steering committee of glaucoma and/or ocular surface disease (OSD) experts and a wider faculty of members from the Educational Club of Ocular Surface and Glaucoma (ECOS-G) collaborated to develop clinical recommendations on best practice in the management of OSI in glaucoma patients using a nonanonymous interactive quasi-Delphi process. Clinical recommendations were formulated by the steering committee based on an analysis of the recent literature to determine unmet needs, together with a web-based interactive survey of faculty members' opinion in seven identified areas of OSI management in glaucoma. Topics included (1) diagnosis of OSD, (2) diagnosis of OSI, (3) causes of OSI, (4) impact of OSD/OSI, (5) prevention of OSI, (6) treatment of OSI, and (7) inflammation and the deep structures of the eye. Faculty members were invited to vote on the clinical recommendations, and the steering committee then determined whether consensus had been achieved. RESULTS: Consensus was obtained on 24 clinical recommendations by 80%-100% of faculty members. There was consensus that OSI should be investigated in all glaucoma patients. The main prevention measure in glaucoma patients with pre-existing OSD was the elimination/minimisation of preserved medications, especially BAK-preserved eye drops. A subtractive treatment strategy rather than an additive strategy is recommended according to OSI/OSD severity to improve the ocular health and/or before glaucoma surgery. CONCLUSION: These recommendations for the management of OSI in glaucoma should be useful to guide decision-making in clinical practice.


Assuntos
Consenso , Glaucoma , Humanos , Glaucoma/diagnóstico , Glaucoma/terapia , Técnica Delphi , Pressão Intraocular/fisiologia , Guias de Prática Clínica como Assunto
11.
Am J Ophthalmol ; 259: 117-130, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37979601

RESUMO

PURPOSE: To evaluate risk factors for failure of Microshunt in glaucoma patients. DESIGN: Multicenter retrospective cohort study. METHODS: The study included 220 eyes from 220 consecutive glaucoma patients undergoing Microshunt implantation at six glaucoma units. Four intraocular pressure (IOP) success criteria were defined: (A) IOP ≤21 mm Hg with ≥20% IOP reduction; (B) IOP ≤18 mm Hg with ≥20% IOP reduction; (C) IOP ≤15 mm Hg with ≥25% IOP reduction; and (D) IOP ≤12 mm Hg with ≥30% IOP reduction from baseline. Kaplan-Meier analysis was used to estimate success rates according to the criteria above, and multivariable Cox models were used to identified risk factors for failure according to criterion A. RESULTS: Success rates varied based on different criteria, ranging from 43.3% to 62.5% (overall success for criteria D and A, respectively) and from 35.3% to 44.4% (complete success for criteria D and A, respectively) at 1-year follow-up. Higher intraoperative MMC concentration was associated with reduced risk of failure to maintain complete (0.4 vs 0.2 mg/mL: hazard ratio [HR] = 0.441, P < .001) and overall (0.4 vs 0.2 mg/mL: HR = 0.360, P = .004) success. For complete success, other risk factors for failure were pseudoexfoliation glaucoma/pigmentary glaucoma (HR = 1.641, P = .004), primary angle closure glaucoma (HR = 1.611, P < .001), and previous non-glaucomatous ocular surgeries (HR = 2.301, P = .002). For overall success, other risk factors for failure were lower preoperative IOP (for 1-mm Hg increase, HR = 0.934, P = .005), higher number of preoperative antiglaucoma agents (HR = 1.626, P < .001), and Microshunt combined with cataract surgery (HR = 1.526, P = .033). CONCLUSIONS: This study identified risk factors for Microshunt failure, highlighting the importance of high intraoperative MMC dose and careful patient selection to optimize surgical success.


Assuntos
Glaucoma , Trabeculectomia , Humanos , Estudos Retrospectivos , Resultado do Tratamento , Mitomicina , Glaucoma/complicações , Glaucoma/cirurgia , Pressão Intraocular , Tonometria Ocular , Fatores de Risco
12.
Ophthalmology ; 120(12): 2470-2475, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23809273

RESUMO

PURPOSE: To determine the ability of ophthalmologists across Europe to match stereoscopic optic disc photographs to visual fields of varying severity. DESIGN: Evaluation and comparison of 2 diagnostic tests. PARTICIPANTS: A total of 109 of 260 invited ophthalmologists in 11 European countries. These had participated in the previous European Optic Disc Assessment Trial (EODAT), a trial on glaucoma diagnostic accuracy based on optic discs only. METHODS: Each participant matched stereo optic disc photographs of 40 healthy and 48 glaucomatous eyes to a visual field chosen from 4 options per disc. The 4 presented visual fields included the corresponding one and 3 other visual fields, varying in severity. The matching accuracy and any inaccuracy per disease severity were calculated. Classification accuracy (as glaucomatous or healthy) was compared with EODAT data. Duplicate slides allowed for the assessment of intraobserver agreement. MAIN OUTCOME MEASURES: Accuracy of matching optic discs with their corresponding visual field and of classifying them as healthy or glaucomatous; intraobserver agreement (κ). RESULTS: The overall accuracy of ophthalmologists for correctly matching stereoscopic optic disc photographs to their visual fields was 58.7%. When incorrectly matched, the observers generally overestimated the visual field severity (P<0.001), notably in eyes with early glaucoma. The intraobserver agreement was, on average, moderate (0.52). CONCLUSIONS: European ophthalmologists correctly matched stereoscopic optic disc photographs to their corresponding visual field in only approximately 59% of cases. In most mismatches, the clinicians overestimated the visual field damage.


Assuntos
Glaucoma/diagnóstico , Oftalmologia/estatística & dados numéricos , Disco Óptico/patologia , Doenças do Nervo Óptico/diagnóstico , Transtornos da Visão/fisiopatologia , Campos Visuais/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Pressão Intraocular , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Hipertensão Ocular/diagnóstico , Oftalmologia/normas , Oftalmoscopia , Fotografação , Reprodutibilidade dos Testes , Testes de Campo Visual , População Branca
13.
Gels ; 9(4)2023 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-37102888

RESUMO

PURPOSE: This study aimed to describe a rare case of bilateral choroidal effusion following a XEN45 implantation. CASE REPORT: An 84-year-old man with primary open-angle glaucoma underwent uneventful ab interno XEN45 device implantation in the right eye. The immediate postoperative period was complicated by hypotony and serous choroidal detachment, which were treated and resolved using steroids and cycloplegic drops. Eight months later, the fellow eye underwent the same surgery, which was followed by choroidal detachment that required transscleral surgical drainage. CONCLUSIONS: This case highlights the importance of a careful postoperative follow-up and a timely intervention in the context of XEN45 implantation, and suggests that choroidal effusion in one eye may be a risk factor for choroidal effusion in the other eye when undergoing the same type of surgery.

14.
Br J Ophthalmol ; 107(1): 62-65, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-34433548

RESUMO

INTRODUCTION: Laser trabeculoplasty is an effective and widely used treatment for glaucoma. A new laser technology, the Eagle direct selective laser trabeculoplasty (DSLT) device, may provide automated, fast, simple, safe and effective laser treatment for glaucoma in a broader range of clinical settings. This trial aims to test the hypothesis that translimbal DSLT is effective and not inferior to selective laser trabeculoplasty (SLT) in reducing intraocular pressure (IOP) in open angle glaucoma (OAG). METHODS AND ANALYSIS: This is a multicentre, randomised, controlled, investigator-masked study. The primary efficacy outcome is intergroup difference in mean change from baseline IOP measured at 6 months. Secondary outcomes include mean percentage reduction in IOP at 3, 6 and 12 months; proportion of participants with at least 20% reduction in IOP from baseline at 6 months; change in ocular hypotensive medications at 12 months and evaluation of safety. Participants were aged >= 40 years with OAG, including exfoliative or pigmentary glaucoma, or ocular hypertension with untreated or washed out IOP 22-35 mm Hg. TREATMENTS: DSLT: 120 shots, 3 ns, 400 µm spot size, energy 1.4-1.8 mJ delivered at the limbus over 2 s. SLT: approximately 100 shots, 3 ns, 400 µm spot size administered 360 degrees at the limbus using any gonioscopy lens, energy 0.3-2.6 mJ. A sample size of 164 is sufficient to detect a non-inferiority margin of 1.95 mm Hg for change from baseline IOP. CLINICAL TRIAL REGISTRATION NUMBER: NCT03750201, ISRCTN14033075.


Assuntos
Glaucoma de Ângulo Aberto , Glaucoma , Terapia a Laser , Trabeculectomia , Humanos , Trabeculectomia/métodos , Pressão Intraocular , Terapia a Laser/métodos , Glaucoma/cirurgia , Resultado do Tratamento
15.
Drugs Today (Barc) ; 58(11): 547-552, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36422516

RESUMO

Dominant optic atrophy (DOA) is caused by OPA1 gene mutation, and it represents one of the most frequently diagnosed forms of hereditary optic neuropathies. This neurodegenerative disorder typically occurs in the first decades of life, and it is often associated with severe visual impairment. For this reason, several treatment options have been examined for the management of DOA, including vitamin supplements, ubiquinone analogues (in particular idebenone) and, more recently, gene therapy. Among them, idebenone has shown the most promising clinical outcomes in recent real-life studies. Furthermore, gene therapy represents also a promising therapeutic approach; however, more evidence in clinical trials is needed. In this review, we will summarize and discuss all the possible treatment options for DOA, in order to identify the current optimal management in these patients, whose visual prognosis remains unfortunately poor and unsatisfactory in the everyday clinical practice.


Assuntos
Atrofia Óptica Autossômica Dominante , Humanos , Atrofia Óptica Autossômica Dominante/genética , Atrofia Óptica Autossômica Dominante/terapia , GTP Fosfo-Hidrolases/genética , Mutação , Terapia Genética
16.
Eur J Ophthalmol ; 32(1): NP254-NP257, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33143445

RESUMO

A 41-year-old woman has come to our attention complaining of decreased visual acuity and monocular diplopia associated with upper and lower limb hypoesthesia. Malabsorption syndrome with vitamin A and E deficiency developed after a bariatric biliopancreatic diversion. The clinical ophthalmological signs and symptoms improved after oral vitamin supplementation therapy. The past medical history is essential in the case of a patient complaining of visual symptoms compatible with vitamin deficiency in order to detect the cause and to start a prompt therapy to avoid irreversible neurological and visual sequelae. The clinical features of our case closely resemble other cases described in the literature of patients affected by vitamin A and E deficiency secondary to malabsorption syndrome.


Assuntos
Desvio Biliopancreático , Síndromes de Malabsorção , Adulto , Feminino , Humanos , Síndromes de Malabsorção/diagnóstico , Síndromes de Malabsorção/etiologia , Vitaminas/uso terapêutico
17.
Case Rep Ophthalmol ; 13(2): 643-648, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36160488

RESUMO

Choroidal osteoma is a rare clinical entity of unknown etiology. It is a benign ossifying tumor characterized by mature bone replacing choroid. It typically affects young females, unilaterally. Vision loss occurs mainly due to photoreceptor degeneration secondary to decalcification and/or development of choroidal neovascularization, especially if located near the macular area. We present a case of an old woman with bilateral choroidal osteomas identified incidentally. An 84-year-old Caucasian woman who was asymptomatic, without clinical features suggestive of choroidal osteoma, was referred to our hospital for a follow-up visit. On the fundus examination, both eyes showed a suspected lesion. B-scan ultrasound demonstrated bilateral highly reflective calcified lesions within the choroid, with an evident cone of shadow, suggestive of choroidal osteoma. Further investigations have performed to confirm the diagnosis. Although the literature reports a more common one-sidedness and typical manifestation of choroidal osteoma in the teenage years, our case report refers to bilateral choroidal osteomas in an elderly woman.

18.
Case Rep Ophthalmol ; 13(3): 984-990, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36605036

RESUMO

Nail-patella syndrome (NPS) is a rare autosomal dominant disease characterized by nail dysplasia, aplastic or hypoplastic patellae, elbow dysplasia, and presence of iliac horns. Renal or ocular abnormalities are also associated with the disease. We report the case of a 57-year-old woman affected by NPS and having haploinsufficiency of the LMX1B gene who experienced severe bilateral chronic angle-closure glaucoma in both eyes and that was successfully managed with a flap-express procedure in the right eye. The left eye had no light perception, and medical treatment was considered. Glaucoma is the most frequent ocular abnormalities observed in association with NPS and usually presents with an open angle. Glaucoma associated with NPS typically has an early onset open-angle phenotype. In fewer cases, it may present with an angle-closure phenotype. Therefore, we emphasize the need for glaucoma case-finding protocols comprehensive of gonioscopy in NPS patients and their relatives.

19.
J AAPOS ; 26(6): 333-336, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36182029

RESUMO

We present the case of a 61-year-old man who reported diplopia due to a right abducens nerve palsy. The patient complained of fever every night (37.5° C), paresthesia of the second and third hand fingers, and he showed an increased C-reactive protein, high erythrocyte sedimentation rate, and high eosinophilia. He had a history of allergic asthma, chronic rhinosinusitis, and surgically treated nasal polyps. His past medical history and labs led us to identify the eosinophilic granulomatosis with polyangiitis (EGPA), also known as Churg-Strauss syndrome. EGPA is a potentially life-threatening condition, and a proper diagnosis was critical to managing this patient's abducens nerve palsy.


Assuntos
Doenças do Nervo Abducente , Asma , Síndrome de Churg-Strauss , Granulomatose com Poliangiite , Sinusite , Masculino , Humanos , Pessoa de Meia-Idade , Síndrome de Churg-Strauss/complicações , Síndrome de Churg-Strauss/diagnóstico , Granulomatose com Poliangiite/complicações , Granulomatose com Poliangiite/diagnóstico , Asma/complicações , Sinusite/complicações , Sinusite/diagnóstico , Doenças do Nervo Abducente/diagnóstico , Doenças do Nervo Abducente/etiologia
20.
J Clin Neurol ; 18(3): 334-342, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35589321

RESUMO

BACKGROUND AND PURPOSE: To identify changes in the choroidal thickness (CT) in multiple sclerosis (MS) patients with and without optic neuritis (ON) using enhanced-depth-imaging optical coherence tomography (EDI-OCT). METHODS: This cross-sectional study included 96 eyes with MS and 28 eyes of healthy controls. All participants underwent an ophthalmologic examination and EDI-OCT scanning (Spectralis, Heidelberg Engineering, Germany) to assess the CT and the retinal nerve fiber layer (RNFL) thickness. MS patients were divided into two groups: 1) with and 2) without a history of ON. The CT was evaluated in the fovea and at six horizontal and six vertical points at 500, 1,000, and 1,500 µm from the fovea. Paired t-tests were used to compare the groups, and p-value<0.05 was considered as significant. RESULTS: At all 13 measurements points, the CT was thicker in MS patients than in the healthy controls and was thinner in eyes with ON than in the contralateral eyes, but these differences were not statistically significant. However, the CT was always larger in all points in eyes with a history of ON than in the control eyes. The RNFL was significantly thinner (p<0.05) in both MS and ON eyes than in the control eyes. CONCLUSIONS: The CT did not differ between MS and control eyes, but it was significantly larger in patients with a history of ON, in whom the RNFL was thinner. Further studies are necessary to establish the possible role of the choroid in MS.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa