Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
1.
J Cardiovasc Electrophysiol ; 34(4): 888-897, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36852902

RESUMO

BACKGROUND/OBJECTIVES: The QDOT-MICRO™ catheter allows very high-power and short-duration (vHPSD) ablation. This study aimed to investigate lesion characteristics using different ablation settings. METHODS: Radiofrequency applications (90 W/4 s, temperature-control mode with 55°C or 60°C target) were performed in excised porcine myocardium using three different approaches: single (SA), double nonrepetitive (DNRA), and double repetitive applications (DRA). Applications were performed with an interval of 1 min for DNRA, and without interval for DRA. RESULTS: A total of 480 lesions were analyzed. Lesion depth and volume were largest for DRA followed by DNRA and SA regardless of catheter direction (depth: 3.8 vs. 3.3 vs. 2.6 mm, p < .001 for all comparisons; volume: 176.6 vs. 145.1 vs. 97.0 mm3 , p < .001 for all comparisons). Surface area was significantly larger for DRA than for SA (45.1 vs. 38.3 mm2 , p < .001) and larger for DNRA than for SA (44.5 vs. 38.3 mm2 , p < .001), but was similar between DRA and DNRA (45.1 vs. 44.5 mm2 , p = .54). Steam-pops more frequently occurred for DRA than for SA (15.6% vs. 4.4%, p = .004) and DNRA (15.6% vs. 6.9%, p = .061), but the incidence was similar between SA and DNRA (4.4% vs. 6.9%, p = 1). Although surface area and lesion volume were larger in lesions with steam-pops than without steam-pops (46.5 vs. 38.1 mm2 , p = .018 and 128.3 vs. 96.8 mm3 , p = .068, respectively), lesions were not deeper (pop(+): 2.5 mm vs. pop(-): 2.6 mm, p = .75). CONCLUSIONS: DNRA produces larger lesions than SA without increasing the risk of steam-pops. DRA produces the largest lesions among the three groups, but with an increased risk of steam-pops. Even with steam-pops, lesions do not become deeper in vHPSD ablation.


Assuntos
Ablação por Cateter , Vapor , Suínos , Animais , Ablação por Cateter/efeitos adversos , Irrigação Terapêutica/efeitos adversos , Desenho de Equipamento , Catéteres
2.
J Cardiovasc Electrophysiol ; 34(4): 908-917, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36906814

RESUMO

INTRODUCTION: The QDOT-MicroTM catheter is a novel irrigated contact force (CF) sensing catheter which benefits from thermocouples for temperature monitoring, allowing temperature-flow-controlled (TFC) ablation. We compared lesion metrics at fixed ablation index (AI) value during TFC-ablation and conventional power-controlled (PC)-ablation. METHODS: A total of 480 RF-applications were performed on ex-vivo swine myocardium with predefined AI targets (400/550) or until steam-pop occurred, using the QDOT-MicroTM (TFC-ablation) and Thermocool SmartTouch SFTM (PC-ablation). RESULTS: Both TFC-ablation and PC-ablation produced similar lesions in volume (218 ± 116 vs. 212 ± 107 mm3 , p = .65); however, lesions using TFC-ablation were larger in surface area (41.3 ± 8.8 vs. 34.8 ± 8.0 mm2 , p < .001) and shallower in depth (4.0 ± 1.0 vs. 4.2 ± 1.1 mm, p = .044). Average power tended to be lower in TFC-alation (34.2 ± 8.6 vs. 36.9 ± 9.2, p = .005) compared to PC-ablation due to automatic regulation of temperature and irrigation-flow. Although steam-pops were less frequent in TFC-ablation (24% vs. 15%, p = .021), they were particularly observed in low-CF (10 g) and high-power ablation (50 W) in both PC-ablation (n = 24/240, 10.0%) and TFC-ablation (n = 23/240, 9.6%). Multivariate analysis revealed that high-power, low-CF, long application time, perpendicular catheter orientation, and PC-ablation were risk factors for steam-pops. Furthermore, activation of automatic regulation of temperature and irrigation-flow was independently associated with high-CF and long application time while ablation power had no significant relationship. CONCLUSIONS: With a fixed target AI, TFC-ablation reduced the risk of steam-pops, producing similar lesions in volume, but with different metrics in this ex-vivo study. However, lower CF and higher power in fixed-AI ablation may increase the risk of steam-pops.


Assuntos
Ablação por Cateter , Vapor , Suínos , Animais , Temperatura , Ablação por Cateter/efeitos adversos , Irrigação Terapêutica/efeitos adversos , Desenho de Equipamento
3.
J Cardiovasc Electrophysiol ; 34(8): 1671-1680, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37337433

RESUMO

INTRODUCTION: Little is known about the impact of blood-pool local impedance (LI) on lesion characteristics and the incidence of steam pops. METHODS: Radiofrequency applications at a range of powers (30, 40, and 50 W), contact forces (CF) (5, 15, and 25 g), and durations (15, 30, 45, and 120 s) using perpendicular/parallel catheter orientation were performed in 40 excised porcine preparations, using a catheter capable of monitoring LI (StablePoint©, Boston Scientific). To simulate the variability in blood-pool impedance, the saline-pool LI was modulated by calibrating saline concentrations. Lesion characteristics were compared under three values of saline-pool LI: 120, 160, and 200 Ω. RESULTS: Of 648 lesions created, steam pops occurred in 175 (27.0%). When power, CF, time, and catheter orientation were adjusted, ablation at a saline-pool impedance of 160 or 200 Ω more than doubled the risk of steam pops compared with a saline-pool impedance of 120 Ω (Odds ratio = 2.31; p = .0002). Lesions in a saline-pool impedance of 120 Ω were significantly larger in surface area (50 [38-62], 45 [34-56], and 41 [34-60] mm2 for 120, 160, and 200 Ω, p < .05), but shallower in depth (4.0 [3-5], 4.4 [3.2-5.3], and 4.5 [3.8-5.5] mmfor 120, 160, and 200 Ω, respectively, p < .05) compared with the other two settings. The correlation between the absolute LI-drop and lesion size weakened as the saline-pool LI became higher (e.g., 120 Ω group (r2 = .30, r2 = .18, and r2 = .16, respectively for 120, 160, and 200 Ω), but the usage of %LI-drop (= absolute LI-drop/initial LI) instead of absolute LI-drop may minimize this effect. CONCLUSIONS: In an experimental model, baseline saline-pool impedance significantly affects the lesion metrics and the risk of steam pops.


Assuntos
Ablação por Cateter , Vapor , Suínos , Animais , Impedância Elétrica , Benchmarking , Ablação por Cateter/efeitos adversos , Solução Salina
4.
Europace ; 26(1)2023 12 28.
Artigo em Inglês | MEDLINE | ID: mdl-38096246

RESUMO

AIMS: The usefulness of coronary venous system mapping has been reported for assessing intramural and epicardial substrates in patients with scar-related ventricular tachycardia (VT). However, there has been little data on mapping from coronary arteries. We investigated the safety and utility of mapping from coronary arteries with a novel over-the-wire multielectrode catheter in scar-related VT patients. METHODS AND RESULTS: Ten consecutive scar-related VT patients with non-ischaemic cardiomyopathy who underwent mapping from a coronary artery were analysed. Six patients underwent simultaneous coronary venous mapping. High-density maps were created by combining the left ventricular endocardium and coronary vessels. Substrate maps were created during the baseline rhythm with 2438 points (IQR 2136-3490 points), including 329 (IQR 59-508 points) in coronary arteries. Abnormal bipolar electrograms were successfully recorded within coronary arteries close to the endocardial substrate in seven patients. During VT, isthmus components were recorded within the coronary vessels in three patients with no discernible isthmus components on endocardial mapping. The ablation terminated the VT from an endocardial site opposite the earliest site in the coronary arteries in five patients. CONCLUSION: The transcoronary mapping with an over-the-wire multielectrode catheter can safely record abnormal bipolar electrograms within coronary arteries. Additional mapping data from the coronary vessels have the potential to assess three-dimensional ventricular substrates and circuit structures in scar-related VT patients.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Humanos , Cicatriz/complicações , Cicatriz/diagnóstico por imagem , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/cirurgia , Arritmias Cardíacas , Ventrículos do Coração , Endocárdio , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
5.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37428890

RESUMO

AIMS: Although the mechanism of an atrial tachycardia (AT) can usually be elucidated using modern high-resolution mapping systems, it would be helpful if the AT mechanism and circuit could be predicted before initiating mapping. OBJECTIVE: We examined if the information gathered from the cycle length (CL) of the tachycardia can help predict the AT-mechanism and its localization. METHODS: One hundred and thirty-eight activation maps of ATs including eight focal-ATs, 94 macroreentrant-ATs, and 36 localized-ATs in 95 patients were retrospectively reviewed. Maximal CL (MCL) and minimal CL (mCL) over a minute period were measured via a decapolar catheter in the coronary sinus. CL-variation and beat-by-beat CL-alternation were examined. Additionally, the CL-respiration correlation was analysed by the RhythmiaTM system. : Both MCL and mCL were significantly shorter in macroreentrant-ATs [MCL = 288 (253-348) ms, P = 0.0001; mCL = 283 (243-341) ms, P = 0.0012], and also shorter in localized-ATs [MCL = 314 (261-349) ms, P = 0.0016; mCL = 295 (248-340) ms, P = 0.0047] compared to focal-ATs [MCL = 506 (421-555) ms, mCL = 427 (347-508) ms]. An absolute CL-variation (MCL-mCL) < 24 ms significantly differentiated re-entrant ATs from focal-ATs with a sensitivity = 96.9%, specificity = 100%, positive predictive value (PPV) = 100%, and negative predictive value (NPV) = 66.7%. The beat-by-beat CL-alternation was observed in 10/138 (7.2%), all of which showed the re-entrant mechanism, meaning that beat-by-beat CL-alternation was the strong sign of re-entrant mechanism (PPV = 100%). Although the CL-respiration correlation was observed in 28/138 (20.3%) of ATs, this was predominantly in right-atrium (RA)-ATs (24/41, 85.7%), rather than left atrium (LA)-ATs (4/97, 4.1%). A positive CL-respiration correlation highly predicted RA-ATs (PPV = 85.7%), and negative CL-respiration correlation probably suggested LA-ATs (NPV = 84.5%). CONCLUSION: Detailed analysis of the tachycardia CL helps predict the AT-mechanism and the active AT chamber before an initial mapping.


Assuntos
Ablação por Cateter , Taquicardia Supraventricular , Humanos , Estudos Retrospectivos , Técnicas Eletrofisiológicas Cardíacas , Taquicardia , Átrios do Coração , Resultado do Tratamento
6.
Circ J ; 87(12): 1757-1764, 2023 11 24.
Artigo em Inglês | MEDLINE | ID: mdl-37899173

RESUMO

BACKGROUND: For lesion size prediction, each input parameter, including ablation energy (AE), and output parameter, such as impedance, is individually used. We hypothesize that using both parameters simultaneously may be more optimal.Methods and Results: Radiofrequency applications at a range of power (30-50 W), contact force (10 g and 20 g), duration (10-60 s), and catheter orientation with normal saline (NS)- or half-normal saline (HNS)-irrigation were performed in excised porcine hearts. The correlations, with lesion size of AE, absolute impedance drop (∆Imp-drop), relative impedance drop (%Imp-drop), and AE*%Imp-drop were examined. Lesion size was analyzed in 283 of 288 lesions (NS-irrigation, n=142; HNS-irrigation, n=141) without steam pops. AE*%Imp-drop consistently showed the strongest correlations with lesion maximum depth (NS-irrigation, ρ=0.91; HNS-irrigation, ρ=0.94), surface area (NS-irrigation, ρ=0.87; HNS-irrigation, ρ=0.86), and volume (NS-irrigation, ρ=0.94; HNS-irrigation, ρ=0.94) compared with the other parameters. Moreover, compared with AE alone, AE*%Imp-drop significantly improved the strength of correlation with lesion maximum depth (AE vs. AE*%Imp-drop, ρ=0.83 vs. 0.91, P<0.01), surface area (ρ=0.73 vs. 0.87, P<0.01), and volume (ρ=0.84 vs. 0.94, P<0.01) with NS-irrigation. This tendency was also observed with HNS-irrigation. Parallel catheter orientation showed a better correlation with lesion depth and volume using ∆Imp-drop, %Imp-drop, and AE*%Imp-drop than perpendicular orientation. CONCLUSIONS: The combination of input and output parameters is more optimal than each single parameter for lesion prediction.


Assuntos
Ablação por Cateter , Solução Salina , Animais , Suínos , Ventrículos do Coração/patologia , Coração , Catéteres , Ablação por Cateter/métodos , Desenho de Equipamento , Impedância Elétrica
7.
Pacing Clin Electrophysiol ; 46(12): 1536-1545, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37957924

RESUMO

BACKGROUND AND AIMS: The safety evaluation of TactiFlex, a novel contact-force sensing catheter with a flexible 4-mm tip irrigated through laser-cut kerfs, has been ongoing. This study aimed to verify the safety of this type of catheter. METHODS: Study 1: Radiofrequency (RF) applications at a range of powers (30-50 W), contact forces (10-20 g), and durations (10-60 s) using perpendicular/parallel catheter orientation with half-normal (HNS) or normal saline irrigation were compared between TactiFlex (4-mm tip) and TactiCath (3.5-mm tip) with temperature-controlled mode in excised porcine hearts. Study 2: The relation between RF applications using TactiFlex and the incidence of steam-pops in the real clinical cases were examined. RESULTS: Study-1: 576 RF lesions were examined. TactiFlex demonstrated a significantly lower risk of steam-pops (5[1.7%] vs. 59[20.5%], p < .0001). Compared to 3.5-mm-tip catheter (TactiCath), 4-mm-tip catheter (TactiFlex) produced smaller lesion volume at perpendicular (193[98-554]mm3 vs. 263[139-436]mm3 , p < .0001), but relatively similar lesion volume at parallel contact (243[105-443]mm3 vs. 278[180-440]mm3 , p = .06). HNS-irrigation tended to increase the lesion volume in both catheters and to increase the incidence of steam-pops with TactiCath, but not with TactiFlex. The cut-off value of %impedance-drop ( = absolute impedance-drop/initial impedance) of 20% predicted steam-pops with a sensitivity = 100% and specificity = 89.6% in TactiFlex. Study-2: 5496 RF applications in 84 patients (51AFs/8ATs/3AVNRTs/4AVRTs/17PVCs/4VTs) using TactiFlex were analyzed. Four steam-pops (0.07%) in three patients with pericardial effusion were observed (%impedance-drop = 24%/26%/29%/35%, respectively). The cut-off value of %impedance-drop = 20%, derived from ex-vivo study, showed sensitivity = 100% and specificity = 90.1% in detecting steam-pops. CONCLUSION: TactiFlex reduced the risk of steam-pops than TactiCath. %impedance-drop ≤ 20% may be reasonable for safely use with a sufficient safety margin. For 4-mm-tip catheter, parallel-contact may be recommended for larger lesion creation.


Assuntos
Ablação por Cateter , Vapor , Humanos , Animais , Suínos , Irrigação Terapêutica , Desenho de Equipamento , Catéteres
8.
Am Heart J ; 231: 82-92, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33098808

RESUMO

BACKGROUND: Pulmonary vein isolation (PVI) is the cornerstone of ablation strategies for atrial fibrillation (AF), and noninferiority of cryoballoon (CB) over radiofrequency (RF) ablation has been previously reported. One of the risk factors of recurrence is left atrium (LA) enlargement. This study aimed to analyze the impact of LA enlargement on the selection of CB or RF ablation for AF patients. METHODS: A total of 2,224 AF patients (64.4 ±â€¯10.7 years, 65.5% male) who underwent PVI were analyzed retrospectively. Left atrial diameter (LAD) and volume (LAV) were measured using echocardiography before the procedures. LA enlargement was defined as LAD ≥40 mm and LAV index (LAVI) ≥35 mL/m2. Patients undergoing CB and RF ablation were propensity score matched, and 376 matched pairs were evaluated. RESULTS: Cox proportional hazard analysis revealed that LAD (95% CI, 1.01-1.05), LAV (95% CI, 1.01-1.02), and LAVI (95% CI, 1.01-1.03) were independent predictors of recurrence. CB showed equivalent clinical outcomes to those of RF with shorter procedure time required for patients without LA enlargement. CB was inferior to RF in patients with LA enlargement (LAD, 74.5% vs 84.6%, P = .028; LAVI, 74.7% vs 83.4%, P = .015), and large LAVI was associated with a higher prevalence of non-PV foci (35% vs 29%, P = .008). CONCLUSIONS: CB ablation may be recommended for patients without enlarged LA based on the short procedure time and efficacy, whereas RF would be more appropriate in large LAs. LAVI may be a valuable reference to predict PVI outcomes and in selecting the ablation method.


Assuntos
Fibrilação Atrial/cirurgia , Cardiomegalia/complicações , Ablação por Cateter/métodos , Criocirurgia/métodos , Átrios do Coração/patologia , Veias Pulmonares/cirurgia , Idoso , Cardiomegalia/diagnóstico por imagem , Ecocardiografia , Feminino , Seguimentos , Átrios do Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Complicações Pós-Operatórias , Pontuação de Propensão , Modelos de Riscos Proporcionais , Veias Pulmonares/diagnóstico por imagem , Recidiva , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
9.
J Cardiovasc Electrophysiol ; 32(5): 1251-1258, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33713521

RESUMO

INTRODUCTION: Non-pulmonary vein (PV) triggers are a major cause of atrial tachyarrhythmia (ATA) recurrence after catheter ablation. However, the effect of the diagnosis-to-ablation time (DAT) on non-PV triggers in persistent atrial fibrillation is unknown. METHODS AND RESULTS: This observational study evaluated 502 consecutive persistent AF patients who underwent initial ablation. We compared 408 patients whose DAT was <3 years with 94 patients whose DAT was ≥3 years. Following PV and posterior wall isolation, 193 non-PV triggers, including 50 AFs, 30 atrial tachycardias (ATs), and 113 repetitive atrial premature beats, were elicited and ablated in 137 (27%) patients. Specifically, 80 non-PV AF/AT triggers were provoked in 64 (13%) patients, being identified more frequently in the DAT ≥ 3 years group than in the DAT < 3 years group (20% vs. 11%, p = .025) especially with a higher prevalence of coronary sinus/inferior left atrial triggers. During a median follow-up of 770 days, the ATA recurrence-free rate was higher in the DAT < 3 years group than the DAT ≥ 3 years group (79% vs. 53% at 2 years, p < .001). In a multivariate analysis, female sex (odds ratio: 2.70, p = .002) and a longer DAT (odds ratio: 1.13/year, p = .008) were predictors of non-PV AF/AT triggers, and a longer DAT (hazard ratio: 1.12/year, p < .001) and non-PV AT/AF triggers (hazard ratio: 1.79, p = .009) were associated with ATA recurrence. CONCLUSION: Early ablation after the first diagnosis of persistent AF may reduce emerging non-PV AF/AT triggers and ATA recurrence.


Assuntos
Fibrilação Atrial , Complexos Atriais Prematuros , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Feminino , Humanos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
10.
Heart Vessels ; 35(12): 1709-1716, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32524235

RESUMO

INTRODUCTION: Little evidence exists regarding cryoballoon ablation (CBA) of paroxysmal atrial fibrillation (PAF) in hemodialysis (HD) patients. We compared CBA and radiofrequency ablation (RFA) of PAF in HD patients, referring to CBA of PAF in non-HD patients. METHODS AND RESULTS: This historical cohort study examined 88 patients who underwent catheter ablation of PAF, including 21 HD patients with a second-generation 28-mm cryoballoon (CB-HD group), 17 HD patients with a non-force-sensing radiofrequency catheter (RF-HD group), and 50 non-HD patients with a cryoballoon (CB-non-HD group). Pulmonary vein (PV) isolation alone aside from cavotricuspid isthmus ablation was performed in 14 (67%) in the CB-HD group, 12 (71%) in the RF-HD group, and 36 (72%) in the CB-non-HD group (P = 0.95), without isoproterenol-induced non-PV triggers. Non-PV trigger ablation was added to the other patients. The Kaplan-Meier estimated 1-year freedom from atrial tachyarrhythmia recurrence without antiarrhythmic drugs after a single procedure was 76%, 59%, and, 92% in the CB-HD, RF-HD, and CB-non-HD groups, respectively (P = 0.002). The mean procedure time was shorter in the CB-HD group than in the RF-HD group (127 vs. 199 min; P < 0.001). In the second procedure, the median number of reconnected pulmonary veins was 0.5 in the CB-HD group versus 2.0 in the RF-HD group (P = 0.17). CONCLUSION: For PAF in HD patients, CBA showed a comparable single-procedure efficacy to that of RFA with a short procedure time. CBA may be a reasonable initial procedure for HD patients suffering from symptomatic PAF.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Criocirurgia , Nefropatias/terapia , Veias Pulmonares/cirurgia , Diálise Renal , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Feminino , Humanos , Nefropatias/diagnóstico , Nefropatias/fisiopatologia , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Veias Pulmonares/fisiopatologia , Recidiva , Diálise Renal/efeitos adversos , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
11.
J Cardiovasc Electrophysiol ; 30(10): 1792-1800, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31310033

RESUMO

INTRODUCTION: Several studies have revealed that second-generation cryoballoon (CB)-based pulmonary vein (PV) isolation is noninferior to radiofrequency (RF)-based PV isolation for patients with drug-refractory paroxysmal atrial fibrillation (AF). However, electrophysiological differences in repeat ablation remain unclear. METHODS AND RESULTS: This study examined electrophysiological differences during the repeat ablation between patients who first underwent RF catheter ablation and CB ablation; PV durability and non-PV AF foci were assessed for these patients. We enrolled 919 and 491 patients who underwent CB ablation (CB group) and RF catheter ablation (RF group), respectively, for paroxysmal AF between January 2013 and June 2017 at our institution. PV isolation using RF ablation involved the left atrium (LA) antrum and part of the LA posterior wall. After 2 years of follow-up, 62 and 80 patients in the CB and RF groups, respectively, underwent repeat ablation. PV reconnections were more frequent in the RF group than in the CB group (left superior PV: 46.2% and 14.5%, P < .001; left inferior PV: 35.0% and 11.2%, P = .001; right superior PV: 40.0% and 22.6%, P = .031; right inferior PV: 36.2% and 19.4%, P = .039; PVs: 39.8% and 16.9%, P < .001). LA AF foci were more frequent in the CB group than in the RF group (27.4% and 7.5%; P = .002). Other non-PV foci were prevalent in both groups. CONCLUSION: Fewer LA-PV reconnections occurred with CB ablation. However, extensive PV isolation may eliminate many LA AF foci.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Criocirurgia , Técnicas Eletrofisiológicas Cardíacas , Taquicardia Supraventricular/cirurgia , Potenciais de Ação , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Recidiva , Reoperação , Estudos Retrospectivos , Fatores de Risco , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/fisiopatologia , Fatores de Tempo
15.
J Interv Card Electrophysiol ; 67(1): 5-12, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38087145

RESUMO

BACKGROUND: Single-shot pulmonary vein isolation (PVI) utilizing cryothermal energy is an effective and safe treatment for atrial fibrillation (AF) patients. A novel cryoballoon system, POLARx™, has been recently introduced. The aim of this study was to compare the efficacy, safety, and biophysical parameters of PVI between the novel cryoballoon system, POLARx™, and the standard cryoballoon system, Arctic Front Advance Pro™ (AFA-Pro), in patients with paroxysmal AF. METHODS: The CONTRAST-CRYO trial is a prospective, multicenter, open-label, randomized controlled study performed at seven large cardiac centers. This study was approved by the central ethics committee or the local ethics committee of each participating hospital and has been registered at UMIN Clinical Trials Registry (UMIN000049948). The trial will assign 200 patients with paroxysmal AF undergoing PVI to POLARx™ and AFA-Pro in a 1:1 randomization. The primary endpoint is the one-shot acute success rate of the right inferior pulmonary vein. Second endpoints include freedom from documented atrial fibrillation, atrial flutter, or atrial tachycardia without antiarrhythmic drugs at 12 months after the procedure, freedom from re-do procedures, the incidence of procedure-related adverse events, freezing duration, and the biophysical parameters during applications for each PV, total procedure and fluoroscopy time, and PVI durability during re-do procedures. CONCLUSION: The CONTRAST-CRYO trial is a prospective, multicenter, randomized study designed to elucidate the difference in the efficacy, safety, and biophysical parameters between POLARx™ and AFA-Pro in paroxysmal AF patients undergoing PVI. The findings from this trial may provide a valuable indication for selecting the optimal cryoballoon system. CLINICAL TRIAL REGISTRATION:  UMIN000049948.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Fibrilação Atrial/epidemiologia , Resultado do Tratamento , Estudos Prospectivos , Criocirurgia/métodos , Antiarrítmicos , Veias Pulmonares/cirurgia , Ablação por Cateter/métodos , Recidiva , Ensaios Clínicos Controlados Aleatórios como Assunto , Estudos Multicêntricos como Assunto
16.
J Arrhythm ; 40(3): 536-551, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38939786

RESUMO

Background: We explore an optimized approach for increasing lesion size using a novel ablation catheter with a surface thermocouple and efficient irrigation in a temperature-control setting. Methods: We conducted radiofrequency applications at various power levels (35 W, 40 W, and 45 W), contact forces (CFs, 10 g/20 g), and durations (60 s/120 s/180 s) in perpendicular/parallel catheter orientations, with normal saline irrigation (NS-irrigation) and Half NS-irrigation (HNS-irrigation) in an ex-vivo model (Step 1). In addition, we performed applications (35 W/40 W/45 W for 60 s/120 s/180 s in NS-irrigation and 35 W/40 W for 60 s/120 s/180 s in HNS-irrigation) in four swine (Step 2), evaluating lesion characteristics and the occurrence of steam pops. Results: In Step 1, out of 288 lesions, we observed 47 (16.3%) steam pops, with 13 in NS-irrigation and 34 in HNS-irrigation (p = .001). Although steam pops were mostly observed with the most aggressive setting (45 W/180 s, 54%) with NS-irrigation, they happened in less aggressive settings with HNS irrigation. Lesion size significantly increased with longer-duration ablation but not with HNS-irrigation. The optimal %impedance-drop cutoff to predict steam pops was 20% with a negative-predictive-value (NPV) = 95.1% including NS- and HNS-irrigation groups, and 22% with an NPV = 96.1% in NS-irrigation group. In Step 2, similar to the ex-vivo model, lesion size significantly increased with longer-duration ablation but not with HNS-irrigation. Steam pops were absent with NS-irrigation (0/35) even with the largest %impedance-drop reaching 31% at 45 W/180 s. All steam pops were observed with HNS-irrigation (6/21, 29%). The optimal %impedance-drop cutoff predicting steam pops was 24% with an NPV = 96.3% including both NS- and HNS-irrigation groups. Conclusions: Rather than using HNS-irrigation, very long-duration of radiofrequency applications up to 45 W/180 s may be recommended to safely and effectively increase lesion dimensions using this catheter with NS-irrigation.

17.
JACC Clin Electrophysiol ; 10(6): 1120-1131, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38551549

RESUMO

BACKGROUND: Catheter ablation is the curative treatment for paroxysmal supraventricular tachycardia (SVT). However, atrial tachycardia (AT) diagnosis is often challenging, especially when SVT is terminated by pacing. OBJECTIVES: This study sought to develop a novel method for AT diagnosis. METHODS: A total of 147 SVTs including 28 ATs, 87 atrioventricular nodal re-entrant tachycardias, and 32 orthodromic reciprocating tachycardias were prospectively studied. Single atrial extrastimulation was performed at the proximal coronary sinus from a coupling interval 20 milliseconds shorter than the tachycardia cycle length and gradually decreased until the His bundle (HB) was first reset and further until the SVT was terminated. The response of the SVT during the first HB resetting and the termination pattern were examined. RESULTS: In 27 of 28 ATs, tachycardia was unaffected when HB resetting whereas, in atrioventricular nodal re-entrant tachycardias or orthodromic reciprocating tachycardias (non-AT), tachycardia was simultaneously reset when HB resetting or was terminated with an atrio-Hisian block. When the coupling interval was further shortened for cases in which tachycardia persisted, all 33 SVTs with tachycardia termination with atrio-Hisian block were non-ATs, whereas 5 ATs and 7 non-ATs were terminated with Hisian-atrial block. The sensitivity, specificity, and positive and negative predictive values of the pattern of tachycardia that was unaffected when HB resetting for AT diagnosis were 96%, 100%, 100%, and 99%, respectively. Those of the pattern of tachycardia termination with atrio-Hisian block for non-AT diagnosis were 92%, 100%, 100%, and 42%, respectively. CONCLUSIONS: Single atrial extrastimulation from the proximal coronary sinus during tachycardia was useful and effective for AT diagnosis.


Assuntos
Fascículo Atrioventricular , Taquicardia Supraventricular , Humanos , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/fisiopatologia , Taquicardia Supraventricular/terapia , Fascículo Atrioventricular/fisiopatologia , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Estudos Prospectivos , Adulto , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico , Taquicardia por Reentrada no Nó Atrioventricular/fisiopatologia , Ablação por Cateter/métodos , Eletrocardiografia , Átrios do Coração/fisiopatologia
18.
Artigo em Inglês | MEDLINE | ID: mdl-38880852

RESUMO

BACKGROUND: The innovative peak frequency mapping facilitates the quantification of electrogram sharpness. However, reference values for normal atrial tissue are currently undefined. In this study, we explored the distribution of peak frequency and omnipolar peak-to-peak voltage (V-max) in a normal heart. METHODS: Twenty-two patients with structurally normal heart were included. Either the right atrium (RA) and superior vena cava (SVC) or the left atrium (LA) and pulmonary veins (PVs) were mapped during sinus rhythm. RESULTS: In total, 13,654 points in the RA and 4143 points in the SVC from 15 patients and 4662 points in the LA and 2761 points in PVs from 7 patients were analyzed. The correlation between peak frequency and V-max was weak (R = 0.223). The median peak frequency was larger in the SVC than in the RA (441 [358-524] Hz vs. 358 [291-441] Hz, P < 0.0001) and in PVs than in the LA (346 [253-441] Hz vs. 323 [262-397] Hz, P < 0.0001). Conversely, the median V-max was smaller in the SVC than in the RA (1.96 [0.77-3.75] mV vs. 4.11 [2.10-6.83] mV, P < 0.0001) and in PVs than in the LA (1.16 [0.33-3.17] mV vs. 4.42 [2.63-6.84] mV, P < 0.0001). More than 95% of peak frequencies were > 174 Hz in the RA and > 185 Hz in the LA, and > 95% of V-maxes were > 0.52 and > 1.07 mV in the RA and LA, respectively. CONCLUSION: Given the limited correlation between peak frequency and V-max, and recognizing their potential to provide distinct information, they can be used complementarily. Employing these parameters to extract varied insights can provide comprehensive understandings of tissue characteristics.

19.
J Arrhythm ; 40(2): 247-255, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38586837

RESUMO

Background: Lesion size is reported to become larger as contact force (CF) increases. However, this has not been systematically evaluated in temperature-guided very high-power short-duration (vHPSD) ablation, which was therefore the purpose of this study. Methods: Radiofrequency applications (90 W/4 s, temperature-control mode) were performed in excised porcine myocardium with four different CFs of 5, 15, 25, and 35 g using QDOT-MICRO™ catheter. Ten lesions for each combination of settings were created, and lesion metrics and steam-pops were compared. Results: A total of 320 lesions were analyzed. Lesion depth, surface area, and volume were smallest for CF of 5 g than for 15, 25, and 35 g (depth: 2.7 mm vs. 2.9 mm, 3.0 mm, 3.15 mm, p < .01; surface area: 38.4 mm2 vs. 41.8 mm2, 43.3 mm2, 41.5 mm2, p < .05; volume: 98.2 mm3 vs. 133.3 mm3, 129.4 mm3, 126.8 mm3, p < .01 for all pairs of groups compared to CF = 5 g). However, no significant differences were observed between CFs of 15-35 g. Average power was highest for CF of 5 g, followed by 15, 25, and 35 g (83.2 W vs. 82.1 W vs. 77.1 W vs. 66.1 W, p < .01 for all pairs), reflecting the higher incidence of temperature-guided power titration with greater CFs (5 g:8.8% vs. 15 g:52.5% vs. 25 g:77.5% vs. 35 g:91.2%, p < .01 for all pairs except for 25 g vs. 35 g). The incidence of steam-pops did not significantly differ between four groups (5 g:3.8% vs. 15 g:10% vs. 25 g:6.2% vs. 35 g:2.5%, not significant for all pairs). Conclusions: For vHPSD ablation, lesion size does not become large once the CF reaches 15 g, and the risk of steam-pops may be mitigated through power titration even in high CFs.

20.
Heart Rhythm ; 2024 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-38460753

RESUMO

BACKGROUND: Unipolar electrograms (uni-EGMs) are an essential part of intracardiac mapping. Although Wilson central terminal (WCT) is conventionally used as a reference for signals, avoidance of contamination by far-field and nonphysiologic signals is challenging. OBJECTIVE: The aim of the study was to explore the impact of an intracardiac indifferent reference electrode close to the recording electrodes, in lieu of WCT, on electrograms. METHODS: Sinus node activation was mapped in patients undergoing catheter ablation by a multielectrode array with a close indifferent electrode (CIE) embedded in the distal end of the catheter shaft. An equal number of points was sequentially acquired at each site with use of CIE as a reference first and subsequently with WCT. Uni-EGMs, bipolar EGMs, and the earliest activation area (defined as the area activated in the first 10 ms of the beat) were compared between CIE- and WCT-based activation maps. RESULTS: Seventeen patients (61 ± 18 years; 76% male) were studied. Uni-EGM voltages acquired with CIE were significantly larger than (n = 11) or comparable to (n = 4) those acquired with WCT. When points from the entire cohort were analyzed altogether, unipolar voltages and their maximum negative dV/dT and bipolar voltages recorded with CIE were significantly larger than those recorded with WCT (2.36 [1.42-3.79] mV vs 1.96 [1.25-3.03] mV, P < .0001; 0.40 [0.18-0.77] mV/s vs 0.35 [0.15-0.71] mV/s, P < .0001; and 1.46 [0.66-2.81] mV vs 1.33 [0.54-2.64] mV, P < .0001, respectively). The earliest activation area was significantly smaller in CIE-based activation maps than in WCT-based ones (0.3 [0.7-1.4] cm2 vs 0.6 [1.0-1.8] cm2, P = .01). CONCLUSION: CIE-based maps were associated with an approximately 20% increase in unipolar voltage and may highlight the origin of a focal activation more clearly than WCT-based ones.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa