Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Opt Express ; 31(20): 33582-33595, 2023 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-37859136

RESUMO

Magnetic field imaging is a valuable resource for signal source localization and characterization. This work reports an optically pumped magnetometer (OPM) based on the free-induction-decay (FID) protocol, that implements microfabricated cesium (Cs) vapor cell technology to visualize the magnetic field distributions resulting from various magnetic sources placed close to the cell. The slow diffusion of Cs atoms in the presence of a nitrogen (N2) buffer gas enables spatially independent measurements to be made within the same vapor cell by translating a 175 µm diameter probe beam over the sensing area. For example, the OPM was used to record temporal and spatial information to reconstruct magnetic field distributions in one and two dimensions. The optimal magnetometer sensitivity was estimated to be 0.43 pT/H z within a Nyquist limited bandwidth of 500 Hz. Furthermore, the sensor's dynamic range exceeds the Earth's field of approximately 50 µT, which provides a framework for magnetic field imaging in unshielded environments.

2.
Sensors (Basel) ; 23(8)2023 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-37112348

RESUMO

Machine learning (ML) is an effective tool to interrogate complex systems to find optimal parameters more efficiently than through manual methods. This efficiency is particularly important for systems with complex dynamics between multiple parameters and a subsequent high number of parameter configurations, where an exhaustive optimisation search would be impractical. Here we present a number of automated machine learning strategies utilised for optimisation of a single-beam caesium (Cs) spin exchange relaxation free (SERF) optically pumped magnetometer (OPM). The sensitivity of the OPM (T/Hz), is optimised through direct measurement of the noise floor, and indirectly through measurement of the on-resonance demodulated gradient (mV/nT) of the zero-field resonance. Both methods provide a viable strategy for the optimisation of sensitivity through effective control of the OPM's operational parameters. Ultimately, this machine learning approach increased the optimal sensitivity from 500 fT/Hz to <109fT/Hz. The flexibility and efficiency of the ML approaches can be utilised to benchmark SERF OPM sensor hardware improvements, such as cell geometry, alkali species and sensor topologies.

3.
Sci Rep ; 12(1): 12888, 2022 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-35902634

RESUMO

Self-oscillating atomic magnetometers, in which the precession of atomic spins in a magnetic field is driven by resonant modulation, offer high sensitivity and dynamic range. Phase-coherent feedback from the detected signal to the applied modulation creates a resonant spin maser system, highly responsive to changes in the background magnetic field. Here we show a system in which the phase condition for resonant precession is met by digital signal processing integrated into the maser feedback loop. This system uses a modest chip-scale laser and mass-produced dual-pass caesium vapour cell and operates in a 50 [Formula: see text]T field, making it a suitable technology for portable measurements of the geophysical magnetic field. We demonstrate a Cramér-Rao lower bound-limited resolution of 50 fT at 1 s sampling cadence, and a sensor bandwidth of 10 kHz. This device also represents an important class of atomic system in which low-latency digital processing forms an integral part of a coherently-driven quantum system.

4.
Rev Sci Instrum ; 91(4): 045103, 2020 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-32357754

RESUMO

We present an unshielded, double-resonance magnetometer in which we have implemented a feed-forward measurement scheme in order to suppress periodic magnetic noise arising from, and correlated with, the mains electricity alternating current line. The technique described here uses a single sensor to track ambient periodic noise and feed forward to suppress it in a subsequent measurement. This feed forward technique has shown significant noise suppression of electrical mains-noise features of up to 22 dB under the fundamental peak at 50 Hz, 3 dB at the first harmonic (100 Hz), and 21 dB at the second harmonic (150 Hz). This technique is software based, requires no additional hardware, and is easy to implement in an existing magnetometer.

5.
Sci Rep ; 7(1): 384, 2017 03 24.
Artigo em Inglês | MEDLINE | ID: mdl-28341834

RESUMO

We have laser cooled 3 × 106 87Rb atoms to 3 µK in a micro-fabricated grating magneto-optical trap (GMOT), enabling future mass-deployment in highly accurate compact quantum sensors. We magnetically trap the atoms, and use Larmor spin precession for magnetic sensing in the vicinity of the atomic sample. Finally, we demonstrate an array of magneto-optical traps with a single laser beam, which will be utilised for future cold atom gradiometry.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa