1.
Curr Opin Cardiol ; 39(1): 6-14, 2024 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-37820074

RESUMO

PURPOSE OF REVIEW: Safe and effective radiofrequency (RF) myocardial ablation requires real-time monitoring of lesion formation. Here, we review conventional and novel approaches proposed to guide titration of RF energy application. RECENT FINDINGS: Conventional monitoring modalities, such as ablation electrode temperature, generator impedance, and tissue electrophysiological properties have been of limited value in predicting efficacy and safety of ablation. Therefore, several input-driven indices have been proposed to improve the quality and durability of RF ablation lesion while maintaining safety. These metrics predominantly incorporate RF power output, duration of RF application, and firmness and stability of electrode-tissue contact. More recently, novel catheters have enabled measuring local impedance at the catheter-tissue interface, which has been found valuable for real-time monitoring of RF lesion formation. SUMMARY: It is likely that using the combination of multiple metrics would be required to improve the quality and safety of RF lesions, but further investigation is still required.


Assuntos
Ablação por Cateter , Humanos , Impedância Elétrica , Miocárdio , Eletrodos
2.
Pediatr Cardiol ; 43(6): 1373-1378, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35257196

RESUMO

The aim of this study is to examine the possible high association between multiple ventricular septal defect (mVSDs) and noncompaction cardiomyopathy (NCM) as same embryological origin, and the effect of depressed ventricular function in NCM cases during the follow-up, using echocardiography. A total of 150 patients with mVSDs were diagnosed in a single center in Saudi Arabia; 40 cases with isolated or associated with minor congenital heart disease were recruited. Three specialist echocardiography consultants confirmed the NCM diagnosis separately using Jenni, Chin and Patrick criteria, and myocardial function was estimated by ejection fraction at admission and at follow-up after surgery. Stata-14 to analyze the data was used. In our cohort of 40 cases with mVSD (median age at diagnosis = 0.5 years; mean follow-up = 4.84 years), 13(33%) had criteria of non-compaction confirmed by the three specialist consultants. All were operated by surgery and 11 hybrid approach (interventional & surgery). A significant relationship between abnormal trabeculations and mVSD with or without non-compaction was observed, 34% vs 66% respectively (p < 0.03, Fisher's exact test). A repeated-measures t-test found the difference between follow-up and preoperative ejection-fractions to be statistically significant (t (39) = 2.07, p < 0.04). Further, the myocardial function in the mVSD non-compaction group normalized substantially postoperatively compared with preoperative assessment (mean difference (MD) 11.77, 95% CI: 4.40-19.14), whilst the mVSD group with normal myocardium had no significant change in the myocardium function (MD 0.74, 95% CI: -4.10-5.58). Thus, treatment outcome appears better in the mVSD non-compaction group than their peers with normal myocardium. Acknowledging the lack of genetic data, it is evident the high incidence of non-compaction in this cohort of patients with mVSD and supports our hypothesis of embryonic/genetic link, unlikely to be explained by acquired cardiomyopathy.


Assuntos
Cardiopatias Congênitas , Comunicação Interventricular , Miocárdio Ventricular não Compactado Isolado , Ecocardiografia , Cardiopatias Congênitas/diagnóstico por imagem , Comunicação Interventricular/diagnóstico por imagem , Comunicação Interventricular/cirurgia , Humanos , Miocárdio Ventricular não Compactado Isolado/diagnóstico por imagem , Miocárdio , Função Ventricular Esquerda
3.
J Cardiovasc Electrophysiol ; 32(11): 3042-3048, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34453369

RESUMO

BACKGROUND: In patients undergoing transvenous lead extraction (TLE), lead dwell time has been recognized as a risk factor for extraction failure and procedure-related complications. OBJECTIVES: The aim of this study was to evaluate the safety and effectiveness of TLE in patients with pacemaker or ICD leads with a dwell time of ≥20 years. METHODS: This is a single-center retrospective study of all patients who underwent TLE of at least 1 pacemaker or ICD leads a dwell time of ≥20 years. RESULTS: During the study period, 124 patients were included in this analysis (50.8% female, mean age: 74.6 ± 10.7 years). Device-related infection was the most common (92.7%) indication for TLE. Extraction was attempted for a total 313 leads, of which 182 leads had dwell times ≥20 years (median: 276 months; interquartile range: 255-300 months). Complete procedural success was achieved in 112/124 patients (90.3%), and clinical success in 119/124 patients (96.0%). Complete removal was achieved for 294 leads (93.9%), partial removal in 10 leads, and failure in 9 leads. Clinical success (combined complete and partial success) rates were higher for leads with dwell times <20 years compared to older leads (99.2% vs. 95.6%, p = .017). Major procedural complications (including 1 death) occurred in 7/124 patients (5.6%). Minor complications were observed in 8 patients (6.5%). CONCLUSIONS: TLE of very old (≥20 years) leads can be performed with reasonable success and safety when conducted at centers with expertise in lead management.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Idoso , Idoso de 80 Anos ou mais , Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Marca-Passo Artificial/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento
4.
J Cardiovasc Electrophysiol ; 32(10): 2722-2728, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34322933

RESUMO

BACKGROUND: Direct oral anticoagulants (DOACs) have increasingly been used for several indications for systemic anticoagulation in patients with cardiac implantable electronic devices (CIEDs). The optimal management of anticoagulation therapy in patients undergoing transvenous lead extraction (TLE) procedures remains uncertain. OBJECTIVES: The aim of this study was to evaluate the feasibility and safety of TLE during minimally interrupted DOAC therapy. METHODS: This is a single-center retrospective study of all patients who underwent TLE of a pacemaker or implantable cardioverter-defibrillator lead while on DOAC therapy. In patients deemed to be at high thromboembolic risk, the last DOAC dose was administered the morning of the day before the procedure (regardless of the type of DOAC) and was restarted as soon as possible after the procedure, without bridging with parenteral anticoagulation. RESULTS: During the study period, a total of 84 patients underwent TLE while on minimally interrupted DOAC therapy (54% female, mean age: 74 ± 12 years). TLE was attempted for 161 leads, with a median lead dwell time of 61 months (interquartile range, 38-101). Complete procedural success was achieved for 156 leads (96.9%) and partial success for additional two leads (1.2%). One patient developed RV perforation and required pericardiocentesis and blood transfusion, but no surgical repair. Two patients developed pocket hematomas requiring invasive evacuation. No systemic or venous thromboembolic events were observed. There was no in-hospital mortality. CONCLUSIONS: In selected CIED patients at high risk for thromboembolism, TLE during minimally interrupted DOAC therapy may be considered when performed at experienced centers.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Idoso , Idoso de 80 Anos ou mais , Anticoagulantes/efeitos adversos , Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
5.
J Cardiovasc Electrophysiol ; 32(6): 1724-1732, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33709412

RESUMO

BACKGROUND: Transvenous lead extraction (TLE) carries a significant risk of major complications, namely bleeding into the pericardial sac or thoracic cavity. While echocardiographic imaging has been recommended for intraprocedural monitoring for those complications, no studies had examined the potential benefits of fluoroscopy alone as an alternative to echocardiography. The aim of this study was to evaluate the utility of fluoroscopy for monitoring intrathoracic bleeding complications during TLE. METHODS: This is a single-center retrospective study of consecutive patients who underwent TLE of a pacemaker or ICD lead with fluoroscopy-only monitoring. At the beginning of each TLE procedure, baseline fluoroscopic images were obtained for both lung fields and the cardiac silhouette. Similar images were acquired again when hypotension develops during the procedure. RESULTS: Fluoroscopy alone (without echocardiographic imaging) was used in 783 consecutive patients (54% women; average age, 71.5 ± 12.9 years) who underwent TLE. There were 93 patients (11.9%) who experienced significant hypotension. Fluoroscopy showed no obvious cause for hypotension in 63 patients. Right ventricular inversion was implied by fluoroscopy in 27 patients. Fluoroscopy detected new pericardial effusion in two patients and new right pleural effusion in one patient, which prompted halting the extraction procedure and therapeutic intervention. Additionally, routine fluoroscopic images revealed the development of an unsuspected new small left pleural effusion in one patient and a pericardial effusion in another. In-hospital mortality rate was 0%. CONCLUSIONS: In selected patients undergoing TLE, fluoroscopy can provide valuable information for identifying or excluding cardiovascular causes during periods of intraprocedural hemodynamic instability.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Idoso , Idoso de 80 Anos ou mais , Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo/efeitos adversos , Feminino , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Marca-Passo Artificial/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento
6.
Pediatr Cardiol ; 42(5): 1111-1118, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33787943

RESUMO

Three-dimensional echocardiography is being used to evaluate left ventricular dimensions and ejection fraction in clinical practice. The validity and normal values have been established in a large group of normal adults, children and neonates. The aim of this study was to compare left ventricular dimensions and ejection fraction obtained from the same 3-dimensional echocardiography datasets using 2 commercially available applications: Philips QLAB and Tomtec 4D LEFT VENTRICLE-ANALYSIS. Fifty consecutive newborns or neonates coming to their first newborn visit within the first 3 weeks of live, were recruited. 38 babies underwent full Echocardiographic evaluation, including the acquisition of several 3-dimensional datasets, while naturally sleeping. Left ventricular dimensions, volumes and ejection fraction were measured using Philips QLAB version 9.0 and results were compared to results of the same datasets, analysed using TomTec 4D LV software. Mean left ventricular diastolic, and systolic volumes indexed to body surface area and ejection fraction were: 24.7 ± 3.6 ml/m2, 9.2 ± 1.3 ml/m2 and 62 ± 3.8% using TomTec and 26.6 ± 3.8 ml/m2, 10.4 ± 2 ml/m2 and 63 ± 3.1% using QLAB, respectively. Mean indexed left ventricular diastolic, and systolic volumes measured with QLAB were significantly higher as compared to TomTec with insignificant difference in the ejection fraction. Normal left ventricular indices obtained from 3-dimensional echocardiography datasets were established, using Philips QLAB and TomTec 4D LV ANALYSIS software. Measurements obtained were significantly different between those venders, and hence, may not be used interchangeably.


Assuntos
Ecocardiografia Tridimensional/normas , Ventrículos do Coração/diagnóstico por imagem , Volume Sistólico/fisiologia , Ecocardiografia Tridimensional/métodos , Feminino , Humanos , Recém-Nascido , Masculino , Valores de Referência , Reprodutibilidade dos Testes , Software/normas
7.
Cardiology ; 136(2): 71-76, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-27562944

RESUMO

OBJECTIVE: Our aim was to evaluate left ventricular (LV) mechanics by using speckle tracking echocardiography (STE) in asymptomatic patients with abnormal origin of the left main coronary artery from the pulmonary trunk (ALCAPA), late after successful repair, in the presence of LV ejection fraction (EF) >50%. METHODS: We studied 30 ALCAPA patients (median age 4 years, range 1-25 years, NYHA class I, LVEF >50%) and 16 healthy age- and sex-matched controls (median age 5 years, range 1-25 years). All underwent standard echocardiographic evaluation and STE. RESULTS: LV dimensions and LVEF (63.6 ± 8.2% vs. 64.1 ± 5.1%, p = 0.826) were not different between patients and controls. Diastolic parameters were significantly abnormal in our patients versus controls (E/e' average: 11.9 ± 5.8 vs. 6.6 ± 3.0, p = 0.0014). Global LV longitudinal strain was significantly lower in ALCAPA patients versus controls (-17.6 ± 3.5% vs. -23.4 ± 3.1%, p < 0.0001). LV torsion (9.1 ± 4.9° vs. 11.9 ± 3.3°, p = 0.046) was significantly impaired in ALCAPA patients. CONCLUSIONS: After successful repair in asymptomatic ALCAPA patients, despite an LVEF >50%, diastolic function, LV longitudinal deformation and LV torsion remain impaired. We suggest including a detailed study of the diastolic function and cardiac mechanics in the clinical follow-up of these patients to identify the subgroup of patients at higher risk.


Assuntos
Síndrome de Bland-White-Garland/fisiopatologia , Volume Sistólico , Disfunção Ventricular Esquerda/fisiopatologia , Adolescente , Adulto , Síndrome de Bland-White-Garland/diagnóstico por imagem , Síndrome de Bland-White-Garland/cirurgia , Criança , Pré-Escolar , Ecocardiografia/métodos , Feminino , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Humanos , Lactente , Masculino , Análise Multivariada , Disfunção Ventricular Esquerda/diagnóstico por imagem , Adulto Jovem
8.
Pacing Clin Electrophysiol ; 38(2): 254-8, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25318466

RESUMO

BACKGROUND: Ablation of the atrioventricular junction (AVJ) combined with pacemaker implantation (the "ablate and pace" approach) has been an effective treatment strategy for patients with atrial fibrillation (AF) when rate control is the goal of therapy and when rapid ventricular rates during AF is refractory to pharmacologic therapy. OBJECTIVE: This report describes the feasibility and safety of catheter ablation of AVJ via a superior vena cava (SVC) approach performed during concurrent pacemaker or defibrillator implantation. METHODS: A total of 170 consecutive patients with drug-refractory AF underwent combined AVJ ablation and pacemaker or defibrillator implantation using the axillary or subclavian venous approach. The acute and long-term success of achieving complete atrioventricular (AV) block, the impact of the ablation procedure on the total procedure time and fluoroscopy duration, and procedural complications were evaluated. RESULTS: A dual-chamber device in 61% of patients and biventricular device in 39% patients. Catheter ablation of the AVJ was acutely successful in 166 patients (97.6%). The mean procedure time of the AVJ ablation was 7.0 ± 3.3 minutes and the mean fluoroscopy time during the ablation procedure was 3.1 ± 3.2 minutes. The average duration of RF energy application required to achieve complete AV block was 129 ± 65 seconds. Procedural complications were observed in seven patients. Complete AV block persisted in 96% of patients during a mean follow-up of 26 ± 16 months. CONCLUSION: Catheter ablation of the AVJ can be performed successfully and safely using the SVC approach in patients undergoing concurrent device implantation, and it may offer several advantages over the conventional femoral approach.


Assuntos
Fibrilação Atrial/terapia , Nó Atrioventricular/cirurgia , Ablação por Cateter/métodos , Cateterismo Venoso Central/métodos , Desfibriladores Implantáveis , Marca-Passo Artificial , Idoso , Fibrilação Atrial/diagnóstico , Terapia Combinada/métodos , Estudos de Viabilidade , Feminino , Seguimentos , Humanos , Estudos Longitudinais , Masculino , Estudos Retrospectivos , Resultado do Tratamento , Veia Cava Superior/cirurgia
9.
Circ Arrhythm Electrophysiol ; 16(6): e011714, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37183700

RESUMO

BACKGROUND: The role of atrioventricular optimization (AVO) to improve cardiac resynchronization therapy outcomes remains controversial. Previous post hoc analyses of a multicenter trial showed that measures of electrical dyssynchrony (right ventricular-left ventricular [LV] or LV electrical delay durations) are associated with patients who benefit from AVO. METHODS: This was a global, multicenter, prospective, randomized trial of de novo cardiac resynchronization therapy implant patients with an right ventricular-LV duration ≥70 ms to determine whether AVO results in greater reverse remodeling. Patients were randomized 1:1 for either an AVO algorithm (SmartDelay) that determines atrioventricular delay and pacing chamber, biventricular or LV only, or a fixed atrioventricular delay of 120 ms with biventricular pacing. Paired echocardiograms performed at baseline and 6 months were evaluated. The primary end point was echocardiographic cardiac resynchronization therapy response, defined dichotomously as a >15% reduction in LV end-systolic volume. RESULTS: A total of 310 patients (n=120 women) were randomized and had completed 6 months of follow-up. The echocardiographic cardiac resynchronization therapy response rate did not statistically differ between the groups (SmartDelay, 74.8%; fixed, 67.7%; P=0.17). Analyses of prespecified secondary end points demonstrated significant improvements in the absolute (median: SmartDelay, -41.0 mL; fixed, -33.0 mL; P=0.01) and relative change in LV end-systolic volume (SmartDelay, -38.3%; fixed, -27.8%; P=0.03) for patients with SmartDelay optimization. Similar results were observed for the relative improvement in LV ejection fraction (SmartDelay, 46.7%; fixed, 32.1%; P=0.050); absolute improvement in LV ejection fraction trended to be higher with SmartDelay (P=0.06). CONCLUSIONS: Analysis of reverse remodeling parameters demonstrated that AVO via SmartDelay, relative to the nonoptimized fixed atrioventricular delay comparator group, improved absolute and relative changes in LV function in patients with longer right ventricular-LV duration. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT03089281.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Feminino , Terapia de Ressincronização Cardíaca/métodos , Estudos Prospectivos , Resultado do Tratamento , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Função Ventricular Esquerda/fisiologia , Remodelação Ventricular/fisiologia
10.
J Innov Card Rhythm Manag ; 12(3): 4452-4455, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33777485

RESUMO

In patients with inappropriate sinus tachycardia, conservative medical management targeting the relief of symptoms is the first line of therapy. Sinus node modification can offer a potential benefit in selected patients with severe, refractory inappropriate sinus tachycardia. Extensive endocardial radiofrequency (RF) ablation of the superior aspect of the sinus node complex is typically required but is often limited by the epicardial location of the sinus node and the proximity of the phrenic nerve. More recently, surgical and catheter-based epicardial approaches to the sinus node have been used to facilitate more direct access to the sinus node and mechanical displacement of the phrenic nerve from ablation target sites. In this case report, we describe a combined epicardial-endocardial sinus node modification procedure in a patient with refractory inappropriate sinus tachycardia and previous unsuccessful endocardial ablation. The Orion™ mini-basket catheter (Boston Scientific, Natick, MA, USA) was used both for mapping the sinus node and for mechanically displacing the phrenic nerve from ablation target sites, which facilitated successful ablation.

11.
Heart Rhythm ; 18(8): 1272-1278, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33781982

RESUMO

BACKGROUND: Transvenous lead extraction (TLE) carries a significant risk of morbidity and mortality. Reliable preprocedural risk predictors to guide resource allocation and optimize procedural safety are lacking. OBJECTIVE: The aim of this study was to evaluate an intraprocedural approach to risk stratification during elective TLE procedures. METHODS: This is a single-center retrospective study of consecutive patients who underwent elective TLE of a pacemaker or implantable cardioverter-defibrillator lead for noninfectious indications. The risk of TLE is judged intraprocedurally only after an attempt is made to extract the target lead as long as high-risk extraction techniques are avoided. TLE was performed in a well-equipped electrophysiology laboratory with rescue strategies in place but in the absence of surgical staff. RESULTS: During the study period, 1000 patients were included in this analysis (527 female (52.7%); mean age 61.5 ± 10.2 years). TLE was attempted for 1362 leads, with a mean lead dwell time of 73 ± 43 months (median 70 months; interquartile range 12-180 months). TLE was successful in 914 patients, partially successful in 10, and failed in 76 patients. A laser sheath was required for extraction of 926 leads (68%). Only 1 patient developed intraprocedural cardiac tamponade requiring emergency pericardiocentesis. None of the patients developed hemothorax or required surgical intervention. CONCLUSION: At experienced centers, intraprocedural risk stratification for TLE that avoids high-risk extraction techniques achieved successful TLE in the majority of patients and can potentially help optimize the balance between efficacy, safety, and efficiency in lead extraction.


Assuntos
Cateterismo Periférico/efeitos adversos , Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo/efeitos adversos , Complicações Intraoperatórias/epidemiologia , Medição de Risco/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Cateterismo Periférico/métodos , Remoção de Dispositivo/métodos , Feminino , Seguimentos , Humanos , Illinois/epidemiologia , Masculino , Pessoa de Meia-Idade , Morbidade/tendências , Estudos Retrospectivos , Fatores de Risco , Taxa de Sobrevida/tendências
12.
JACC Clin Electrophysiol ; 7(1): 26-35, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33478709

RESUMO

OBJECTIVES: This study assessed the management approach and outcome of subacute (1 to 30 days post-implantation) and delayed (>30 days) cardiac perforation by pacemaker or implantable cardioverter-defibrillator (ICD) leads. BACKGROUND: Implantation of pacemaker and ICD leads is associated with a small but serious risk of cardiac perforation. Appropriate management remains uncertain. METHODS: The study population included all patients referred to a single institution for subacute or delayed lead perforation after pacemaker or ICD implantation (identified after hospital discharge) during the period from 2007 to 2020. The approach and outcome of lead management were retrospectively assessed. RESULTS: Fifty-four cases of cardiac perforation were identified (35 females; mean age: 75.5 ± 9.7 years). Cardiac perforation was related to a pacemaker lead in 36 patients, and the perforating leads were originally placed in the right ventricular apex in 41 patients. The average time from lead implantation to first presentation of symptoms of perforation was 60.8 ± 89.1 days (range 2 to 412 days). Symptoms suggestive of cardiac perforation were reported by 31 patients (57.4%). Twenty three patients were asymptomatic, in whom lead perforation was discovered incidentally on radiographic imaging, suggesting lead migration or anomalous electrical data on device interrogation. In all patients, the leads were removed or repositioned by the percutaneous approach, with no major periprocedural complications and without surgical intervention. CONCLUSIONS: In this largest series to date of subacute or delayed cardiac device lead perforation, percutaneous repositioning or replacement of the perforating lead was found to be a safe and effective management approach.


Assuntos
Desfibriladores Implantáveis , Traumatismos Cardíacos , Marca-Passo Artificial , Idoso , Desfibriladores Implantáveis/efeitos adversos , Estudos de Viabilidade , Feminino , Traumatismos Cardíacos/epidemiologia , Traumatismos Cardíacos/etiologia , Humanos , Marca-Passo Artificial/efeitos adversos , Estudos Retrospectivos
13.
Europace ; 12(11): 1654-5, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20601362

RESUMO

We report a case of inadvertent transarterial implantation of dual-chamber pacemaker leads; the ventricular lead positioned across the aortic valve into the left ventricle and the atrial lead curving in the aortic root with the tip positioned into the left circumflex artery, resulting in acute myocardial infarction. The diagnosis was made based on the finding on the chest X-ray, surface ECG, and coronary angiography.


Assuntos
Eletrodos Implantados/efeitos adversos , Infarto do Miocárdio/etiologia , Marca-Passo Artificial/efeitos adversos , Implantação de Prótese/efeitos adversos , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Dor no Peito/diagnóstico por imagem , Dor no Peito/etiologia , Angiografia Coronária , Eletrocardiografia , Feminino , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Humanos , Infarto do Miocárdio/diagnóstico por imagem , Falha de Prótese , Resultado do Tratamento
14.
Heart Rhythm ; 17(7): 1115-1122, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32087357

RESUMO

BACKGROUND: The World-wide Randomized Antibiotic Envelope Infection Prevention trial reported a 40% reduction in major cardiac implantable electronic device (CIED) infections within 12 months of the procedure with the use of an antibacterial-eluting envelope (TYRX Absorbable Antibacterial Envelope, Medtronic, Mounds View, MN). OBJECTIVE: The purpose of this report was to describe the longer-term (>12 months) envelope effects on infection reduction and complications. METHODS: All trial patients who underwent CIED replacement, upgrade, revision, or initial cardiac resynchronization therapy - defibrillator implantation received standard-of-care infection prophylaxis and were randomized in a 1:1 ratio to receive the envelope or not. CIED infection incidence and procedure and system-related complications were characterized through all follow-up (36 months) by using Cox proportional hazards regression modeling. RESULTS: In total, 6800 patients received their intended randomized treatment (3371 envelope; 3429 control; mean follow-up period 21.0 ± 8.3 months). Major CIED-related infections occurred in 32 envelope patients and 51 control patients (Kaplan-Meier [KM] estimate 1.3% vs 1.9%; hazard ratio [HR] 0.64; 95% confidence interval [CI] 0.41-0.99; P = .046). Any CIED-related infection occurred in 57 envelope patients and 84 control patients (KM estimate 2.1% vs 2.8%; HR 0.69; 95% CI 0.49-0.97; P = .030). System- or procedure-related complications occurred in 235 envelope patients and 252 control patients (KM estimate 8.0% vs 8.2%; HR 0.95; 95% CI 0.79-1.13; P < .001 for noninferiority); the most common were lead dislodgment (1.1%), device lead damage (0.5%), and implant site hematoma (0.4%). Implant site pain occurred less frequently in the envelope group (0.1% vs 0.4%; P = .067). There were no (0.0%) reports of allergic reactions to the components of the envelope (mesh, polymer, or antibiotics). CONCLUSION: The effects of the TYRX envelope on the reduction of the risk of CIED infection are sustained beyond the first year postprocedure, without an increased risk of complications.


Assuntos
Antibacterianos/uso terapêutico , Antibioticoprofilaxia/métodos , Desfibriladores Implantáveis/efeitos adversos , Infecções Relacionadas à Prótese/prevenção & controle , Idoso , Feminino , Seguimentos , Humanos , Incidência , Masculino , Estudos Prospectivos , Infecções Relacionadas à Prótese/epidemiologia , Fatores de Risco , Método Simples-Cego , Fatores de Tempo
15.
Europace ; 11(9): 1235-7, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19578175

RESUMO

Supraventricular tachycardia (SVT) with ventriculoatrial (VA) block. We report the case of a 25-year-old patient with paroxysmal SVT and intermittent VA block. Atrioventricular nodal re-entrant tachycardia with upper common pathway block and orthodromic nodoventricular or nodofascicular re-entrant tachycardia was considered in the differential diagnosis. Diagnostic characteristics were most compatible with non-re-entrant junctional tachycardia. The arrhythmia was cured by ablation at the right atrial posterior septum.


Assuntos
Bloqueio Atrioventricular/diagnóstico , Bloqueio Atrioventricular/cirurgia , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/cirurgia , Adulto , Bloqueio Atrioventricular/complicações , Feminino , Humanos , Taquicardia Supraventricular/complicações , Resultado do Tratamento
16.
J Interv Card Electrophysiol ; 24(1): 63-6, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19016315

RESUMO

Inadvertent placement of pacemaker and implantable cardioverter-defibrillator (ICD) leads in the left ventricle (LV) is a rare but well-recognized complication of device implantation [1]. We report a case of inadvertent transarterial implantation of dual-chamber ICD leads; the ventricular lead positioned in the LV and the atrial lead positioned in the aortic root. The tip of the atrial lead migrated across the aortic wall and captured the epicardial surface of the left atrium. The diagnosis was made 5 years after the implantation procedure with no apparent adverse events directly related to left heart lead placement.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Eletrodos Implantados/efeitos adversos , Migração de Corpo Estranho/etiologia , Átrios do Coração/lesões , Traumatismos Cardíacos/etiologia , Ventrículos do Coração/lesões , Ferimentos Penetrantes/etiologia , Idoso de 80 Anos ou mais , Feminino , Humanos
17.
J Comput Assist Tomogr ; 33(6): 946-51, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19940665

RESUMO

OBJECTIVES: To evaluate predictor variables and accuracy of left atrial appendage (LAA) filling defects seen on multidetector computed tomographic (MDCT) scan in predicting LAA thrombus in patients undergoing pulmonary vein (PV) isolation procedure. METHODS: Electrocardiogram-gated 64-slice MDCT and transesophageal echocardiography (TEE) were undertaken in 51 consecutive patients with nonvalvular atrial fibrillation who were referred for circumferential antral pulmonary vein isolation. RESULTS: In 51 patients (37 men; mean age, 64 years), left atrium (LA) diameter emerged as the predictor of LAA filling defects (odds ratio, 4.9; 95% confidence interval, 1.19-20.25). Left atrial appendage filling defects had sensitivity of 100%, specificity of 95.92%, positive predictive value of 0.5, and negative predictive value of 1, for thrombi seen on TEE image. A mean LAA/ascending aorta Hounsfield unit ratio of 0.78 or less was identified as a sensitive predictor of thrombus on TEE (sensitivity, 100%; specificity, 87.8%; positive predictive value, 0.25; and negative predictive value, 1). CONCLUSIONS: A larger LA predisposes to LAA filling defects on MDCT scan. Pending prospective validation, absence of LAA filling defects on 64-slice MDCT may reliably exclude LAA thrombi in patients with nonvalvular atrial fibrillation obviating the need for TEE.


Assuntos
Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ecocardiografia Transesofagiana/métodos , Veias Pulmonares/cirurgia , Tomografia Computadorizada por Raios X/métodos , Apêndice Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Meios de Contraste , Eletrocardiografia , Feminino , Humanos , Iopamidol , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Veias Pulmonares/diagnóstico por imagem , Sensibilidade e Especificidade
18.
J Interv Card Electrophysiol ; 22(1): 71-4, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18266095

RESUMO

We report the case of a 65-year-old man with chronic atrial fibrillation (AF) and severe ischemic cardiomyopathy who underwent implantation of a prophylactic single-chamber implantable cardioverter-defibrillator (ICD). The patient experienced inappropriate ICD therapies due to oversensing of pectoral muscle myopotential secondary to reversal of the defibrillator coil terminal pins in the ICD header. Recognizing this possibility is important to avoid misinterpretation of spontaneous oversensing as hardware failure (e.g., lead fracture or insulation breech) and potentially unnecessary ICD system surgical intervention, including lead extraction.


Assuntos
Fibrilação Atrial/terapia , Desfibriladores Implantáveis/efeitos adversos , Erros Médicos , Idoso , Humanos , Masculino
19.
J Interv Card Electrophysiol ; 65(3): 585-587, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35476307
20.
Int J Cardiol ; 241: 163-167, 2017 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-28325614

RESUMO

BACKGROUND: In patients who have undergone arterial switch operation (ASO) for d-transposition of the great arteries a gothic aortic arch (GA) morphology has been found and it has been associated with abnormal aortic bio-elastic properties. HYPOTHESIS: GA is frequent in ASO patients and may have an impact on cardiac mechanics. Our study aims were to assess 1- the occurrence of GA in a large sample of patients after ASO; 2- the association between GA and aortic bio-elastic properties; and 3- the impact of GA on left ventricular (LV) function using speckle tracking echocardiography (STE). METHODS: We studied one hundred and five asymptomatic patients, who have undergone first stage ASO for d-TGA, with normal left ventricular ejection fraction (LVEF ≥53%). RESULTS: Forty-six (44%) patients showed a GA (mean age 11.5±7.2years, 26 males) while fifty-nine (56%) patients (mean age 9.6±6.7years, 37 males) did not present GA. The two groups were comparable for age, sex, BSA, and office blood pressure values. In group GA aortic root was significantly dilated (27.4±7.5mm vs. 21.2±6.9mm, p<0.0001), aortic stiffness index (Group GA=1.8±1.2 vs. 1.4±0.7, p=0.025) was significantly increased, left atrial volume was larger (p=0.0145), global longitudinal strain (Group GA=-18.4±2.5% vs. -20.1±3.3%, p=0.012) and basal LV longitudinal strains (Group GA=-16.9±4.8% vs. -20.4±7.0%, p=0.013) were significantly reduced. CONCLUSIONS: After ASO the presence of a GA is associated with a significantly dilated aortic root, stiffer aortic wall, larger left atrial volume, and worse LV longitudinal systolic deformations, well known predictors of cardiovascular morbidity and mortality.


Assuntos
Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Transposição das Grandes Artérias/tendências , Transposição dos Grandes Vasos/diagnóstico por imagem , Transposição dos Grandes Vasos/cirurgia , Adolescente , Transposição das Grandes Artérias/efeitos adversos , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/fisiopatologia , Estudos Prospectivos , Volume Sistólico/fisiologia , Transposição dos Grandes Vasos/fisiopatologia , Adulto Jovem