Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 116
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Magn Reson Imaging ; 57(4): 1199-1211, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-35861188

RESUMO

BACKGROUND: Although endovascular aneurysmal repair (EVAR) is a preferred treatment for abdominal aortic aneurysm (AAA) owing to its low invasiveness, its impact on the local hemodynamics has not been fully assessed. PURPOSE: To elucidate how EVAR affects the local hemodynamics in terms of energy loss (EL). STUDY TYPE: Prospective single-arm study. FIELD STRENGTH/SEQUENCE: A 3.0 T/4D flow MRI using a phase-contrast three-dimensional cine-gradient-echo sequence. POPULATION: A total of 13 consecutive patients (median [interquartile range] age: 77.0 [73.0, 78.8] years, 11 male) scheduled for EVAR as an initial treatment for fusiform AAA. ASSESSMENT: 4D flow MRI covering the abdominal aorta and bilateral common iliac arteries and the corresponding stent-graft (SG) lumen was performed before and after EVAR. Plasma brain natriuretic peptide (BNP) was measured within 1 week before and 1 month after EVAR. The hemodynamic data, including mean velocity and the local EL, were compared pre-/post-EVAR. EL was correlated with AAA neck angle and with BNP. Patients were subdivided into deformed (N = 5) and undeformed SG subgroups (N = 8) and pre-/post-EVAR BNP compared in each. STATISTICS: Parametric or nonparametric methods. Spearman's rank correlation coefficients (r). The interobserver/intraobserver variabilities with Bland-Altman plots. A P value < 0.05 is considered significant. RESULTS: The mean velocity (cm/sec) at the AAA was five times greater after EVAR: 4.79 ± 0.32 vs. 0.91 ± 0.02. The total EL (mW) increased by 1.7 times after EVAR: 0.487 (0.420, 0.706) vs. 0.292 (0.192, 0.420). The total EL was proportional to the AAA neck angle pre-EVAR (r = 0.691) and post-EVAR (r = 0.718). BNP (pg/mL) was proportional to the total EL post-EVAR (r = 0.773). In the deformed SG group, EL (0.349 [0.261, 0.416]) increased 2.4-fold to 0.848 (0.597, 1.13), and the BNP 90.3 (53.6, 105) to 100 (67.2, 123) post-EVAR. CONCLUSION: The local EL showed a 1.7-fold increase after EVAR. The larger increase in the EL in the deformed SG group might be a potential concern for frail patients. EVIDENCE LEVEL: 1 TECHNICAL EFFICACY: Stage 2.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Idoso , Humanos , Masculino , Imageamento por Ressonância Magnética , Estudos Prospectivos , Estudos Retrospectivos , Resultado do Tratamento , Feminino
2.
Echocardiography ; 37(2): 323-330, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-32003907

RESUMO

BACKGROUND: Mechanical stress caused by blood flow, such as wall shear stress (WSS) and its related parameters, is key moderator of endothelial degeneration. However, an in vivo method to measure WSS on heart valves has not been developed. METHODS: We developed a novel approach, based on vector flow mapping using intraoperative epi-aortic echocardiogram, to measure WSS and oscillatory shear index (OSI) on the aortic valve. We prospectively enrolled 15 patients with normal valves, who underwent coronary artery bypass graft. RESULTS: Systolic WSS on the ventricularis (2.40 ± 0.44 Pa [1.45-3.00 Pa]) was higher than systolic WSS on the fibrosa (0.33 ± 0.08 Pa [0.14-0.47 Pa], P < .001) and diastolic WSS on the ventricularis (0.18 ± 0.07 Pa [0.04-0.28 Pa], P < .001). Oscillatory shear index on the fibrosa was higher than on the ventricularis (0.29 ± 0.04 [0.24-0.36] vs 0.05 ± 0.03 [0.01-0.12], P < .001). A pilot study involving two patients with severe aortic regurgitation showed significantly different values in fluid dynamics. CONCLUSION: Vector flow mapping method using intraoperative epi-aortic echocardiogram is an effective way of measuring WSS and OSI on normal aortic leaflet in vivo, allowing for better understanding of the pathophysiology of aortic valve diseases.


Assuntos
Valva Aórtica , Doenças das Valvas Cardíacas , Aorta , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Velocidade do Fluxo Sanguíneo , Hemodinâmica , Humanos , Hidrodinâmica , Projetos Piloto , Estresse Mecânico
3.
Kyobu Geka ; 73(1): 22-27, 2020 Jan.
Artigo em Japonês | MEDLINE | ID: mdl-31956246

RESUMO

Functional mitral stenosis after mitral valve repair for degenerative mitral regurgitation( DMR) is an evolving concept. Mitral annuloplasty devices stabilize the mitral annulus, reduce leaflet stress and increase leaflet coaptation, which leads to improvement of repair durability at the cost of dynamic and physiological annular movement and diastolic annular area. An elevation in rest and peak transmitral gradient has been observed in some patients with annuloplasty devices, and this elevation may associate with worse prognosis as late atrial fibrillation or lower functional capacity after surgery. In this review, we summarize the current reports describing functional mitral stenosis after mitral valve repair for DMR.


Assuntos
Anuloplastia da Valva Mitral , Insuficiência da Valva Mitral , Estenose da Valva Mitral , Humanos , Valva Mitral , Estenose da Valva Mitral/cirurgia , Prognóstico
4.
Heart Vessels ; 34(2): 296-306, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30155660

RESUMO

Although the suction force that moves blood into the left ventricle during early diastole is thought to play an important role in diastolic function, there have been a few studies of this phenomenon in normal children. Suction force is measured as the intraventricular pressure difference (IVPD) and intraventricular pressure gradient (IVPG), which is calculated as IVPD divided by left ventricular length. The purpose of this study was to determine the suction force in infants, children, and adolescents using IVPD and IVPG. We included 120 normal children categorized into five groups based on age: G1 (0-2 years), G2 (3-5 years), G3 (6-8 years), G4 (9-11 years), and G5 (12-16 years). The total, basal, and mid-apical IVPD and IVPG were calculated using color M-mode Doppler imaging of the mitral valve inflow using the Euler equation. The total IVPD increased with age from G1 to G5 (1.75 + 0.51 vs. 2.95 + 0.72 mmHg, respectively; p < 0.001), due to an increase in mid-apical IVPD with constant basal IVPD. Although total IVPG was constant, mid-apical IVPG was larger in G5 than in G1 (0.21 + 0.06 vs. 0.16 + 0.07 mmHg/cm, respectively; p = 0.006). Total, basal, and mid-apical IVPDs were significantly correlated with age and the parameters of heart size and mitral annular e'. Mid-apical IVPG correlated with age and e' positively, but basal IVPG did with age negatively and did not with e'. The suction force increased at the mid-apical segment, correlating with increasing heart size and developing left ventricular relaxation, even after adjustment for left ventricular length.


Assuntos
Função do Átrio Esquerdo/fisiologia , Ecocardiografia Doppler em Cores/métodos , Átrios do Coração/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Função Ventricular Esquerda/fisiologia , Pressão Ventricular/fisiologia , Adolescente , Criança , Pré-Escolar , Diástole , Estudos de Viabilidade , Feminino , Seguimentos , Humanos , Lactente , Recém-Nascido , Masculino , Estudos Prospectivos , Valores de Referência
5.
Heart Vessels ; 34(6): 992-1001, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30673819

RESUMO

Cardiac dysfunction due to cardiotoxicity from anthracycline chemotherapy is a leading cause of morbidity and mortality in survivors of childhood cancer. The intraventricular pressure gradient (IVPG) of the left ventricle (LV) is the suction force of blood from the left atrium to the LV apex during early diastole and is a sensitive indicator of diastolic function. We assessed IVPG as a new indicator of the cardiac dysfunction in survivors of childhood cancer after anthracycline therapy. We performed a prospective echocardiographic study on 40 survivors of childhood cancer aged 6-26 years who received anthracycline therapy (group A) and 53 similar-age normal controls (group N). The subjects were divided into the younger groups, N1 and A1 (age < 16 years); older groups, N2 and A2 (age ≥ 16 years). IVPG was calculated using color M-mode Doppler imaging of the mitral inflow using Euler's equation. Total IVPG was divided into the basal and mid-to-apical IVPG to demonstrate more clearly the mechanisms of the LV diastolic suction force. The total anthracycline dose was 16.2-600.0 mg/m2 (median 143.5 mg/m2). Total IVPG significantly decreased in group A2 compared with that in group N2 (0.39 ± 0.07 vs. 0.29 ± 0.11 mmHg/cm; p = 0.010). The mid-to-apical IVPG significantly decreased in groups A1 and A2 compared with that in groups N1 and N2, respectively (N1 vs. A1: 0.20 ± 0.05 vs. 0.16 ± 0.05 mmHg/cm, p = 0.036; N2 vs. A2: 0.21 ± 0.06 vs. 0.14 ± 0.06 mmHg/cm, p = 0.001). Basal IVPG, E wave, and E/e' were not significantly different between patients and normal controls. The total and mid-to-apical IVPG, especially mid-to-apical IVPG, could be sensitive new indicators in survivors of childhood cancer after anthracycline therapy.


Assuntos
Antraciclinas/efeitos adversos , Antibióticos Antineoplásicos/efeitos adversos , Cardiopatias/induzido quimicamente , Neoplasias/tratamento farmacológico , Pressão Ventricular , Adolescente , Adulto , Antraciclinas/uso terapêutico , Antibióticos Antineoplásicos/uso terapêutico , Sobreviventes de Câncer , Cardiotoxicidade , Criança , Estudos Transversais , Ecocardiografia , Feminino , Seguimentos , Cardiopatias/diagnóstico por imagem , Humanos , Japão , Masculino , Estudos Prospectivos , Função Ventricular Esquerda , Adulto Jovem
6.
Kyobu Geka ; 72(4): 297-305, 2019 Apr.
Artigo em Japonês | MEDLINE | ID: mdl-31266916

RESUMO

Recently, number of adult congenital heart disease(ACHD) patients are rapidly increasing, but statistical evidences in adult congenital heart surgery are not sufficient because of its short history in addition to the complicated pathophysiology of ACHD. Therefore, a "heart team" including surgeons, pediatricians, and cardiologists are required, and blood flow imaging and 4-dimensional (4D) imaging plays an essential role in perioperative patient management. Enhanced 3-dimensional computed tomography( 3D-CT) scan is useful to determine cardiopulmonary bypass strategies in reoperation, and 4D flow magnetic resonance imaging( MRI) is useful in assessment of complicated hemodynamics. Diastolic function of systemic ventricle is very important in right side heart valve surgery or univentricular heart surgery, echocardiography is essential to examine the valve structure, and electrophysiological mapping is useful in concomitant arrhythmia surgery. This article describes the indications, procedures, and perioperative managements of surgery in the right ventricular outflow tract, tricuspid valve, aortic root, Fontan circulation, and systemic right ventricle.


Assuntos
Cardiopatias Congênitas , Cirurgia Torácica , Adulto , Cardiopatias Congênitas/cirurgia , Ventrículos do Coração , Humanos , Valva Tricúspide
7.
Pediatr Cardiol ; 39(4): 731-742, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29453683

RESUMO

The optimal timing for pulmonary valve replacement after Tetralogy of Fallot (TOF) repair remains controversial. In this study, we estimated the feasibility of using flow energy loss (FEL) to predict right ventricular (RV) deterioration due to pulmonary regurgitation after TOF repair. We examined RV outflow tract (RVOT) flow in nine patients who underwent TOF or double-outlet right ventricle repair in the intervention group (Group I) and compared them with three healthy children in the control group (Group C). We evaluated flow across the RVOT and pulmonary valve by vector flow mapping (VFM) on echocardiography and by phase contrast-magnetic resonance imaging (PC-MRI). Next, we calculated FEL and analyzed the relationship between FEL and clinical parameters of RV function. The mean FEL was significantly greater in Group I than in Group C (p = 0.002). Flow pattern and FEL were comparable by VFM and PC-MRI at the same phase 14.6 years after TOF repair. There was a significant positive correlation for the cardiothoracic ratio with both the mean FEL [correlation coefficient (r) = 0.78; p = 0.012] and the diastolic peak FEL (r = 0.75; p = 0.021) in Group I. There was also a significant positive correlation between the serial change in QRS duration with both the mean FEL (r = 0.82; p = 0.014) and the diastolic FEL (r = 0.70; p = 0.052) in Group I. FEL by VFM is an effective tool for evaluating ventricular deterioration caused by RV workload.


Assuntos
Ecocardiografia/métodos , Imageamento por Ressonância Magnética/métodos , Insuficiência da Valva Pulmonar/complicações , Tetralogia de Fallot/cirurgia , Disfunção Ventricular Direita/diagnóstico por imagem , Adolescente , Cateterismo Cardíaco/métodos , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/métodos , Criança , Pré-Escolar , Estudos de Viabilidade , Feminino , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Hemodinâmica/fisiologia , Humanos , Lactente , Masculino , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/fisiopatologia , Insuficiência da Valva Pulmonar/etiologia , Insuficiência da Valva Pulmonar/cirurgia , Estudos Retrospectivos , Disfunção Ventricular Direita/etiologia , Função Ventricular Direita/fisiologia
8.
BMC Cardiovasc Disord ; 17(1): 21, 2017 01 09.
Artigo em Inglês | MEDLINE | ID: mdl-28068909

RESUMO

BACKGROUND: Vector flow mapping, a novel flow visualization echocardiographic technology, is increasing in popularity. Energy loss reference values for children have been established using vector flow mapping, but those for adults have not yet been provided. We aimed to establish reference values in healthy adults for energy loss, kinetic energy in the left ventricular outflow tract, and the energetic performance index (defined as the ratio of kinetic energy to energy loss over one cardiac cycle). METHODS: Transthoracic echocardiography was performed in fifty healthy volunteers, and the stored images were analyzed to calculate energy loss, kinetic energy, and energetic performance index and obtain ranges of reference values for these. RESULTS: Mean energy loss over one cardiac cycle ranged from 10.1 to 59.1 mW/m (mean ± SD, 27.53 ± 13.46 mW/m), with a reference range of 10.32 ~ 58.63 mW/m. Mean systolic energy loss ranged from 8.5 to 80.1 (23.52 ± 14.53) mW/m, with a reference range of 8.86 ~ 77.30 mW/m. Mean diastolic energy loss ranged from 7.9 to 86 (30.41 ± 16.93) mW/m, with a reference range of 8.31 ~ 80.36 mW/m. Mean kinetic energy in the left ventricular outflow tract over one cardiac cycle ranged from 200 to 851.6 (449.74 ± 177.51) mW/m with a reference range of 203.16 ~ 833.15 mW/m. The energetic performance index ranged from 5.3 to 37.6 (18.48 ± 7.74), with a reference range of 5.80 ~ 36.67. CONCLUSIONS: Energy loss, kinetic energy, and energetic performance index reference values were defined using vector flow mapping. These reference values enable the assessment of various cardiac conditions in any clinical situation.


Assuntos
Circulação Coronária , Ecocardiografia Doppler em Cores/métodos , Ventrículos do Coração/diagnóstico por imagem , Contração Miocárdica , Imagem de Perfusão do Miocárdio/métodos , Função Ventricular Esquerda , Adulto , Fenômenos Biomecânicos , Transferência de Energia , Feminino , Voluntários Saudáveis , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Variações Dependentes do Observador , Valor Preditivo dos Testes , Valores de Referência , Reprodutibilidade dos Testes , Adulto Jovem
9.
Heart Vessels ; 32(8): 1032-1044, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28444501

RESUMO

Computational fluid dynamics (CFD) are the gold standard in studying blood flow dynamics. However, CFD results are dependent on the boundary conditions and the computation model. The purpose of this study was to validate CFD methods using comparison with actual measurements of the blood flow vector obtained with four-dimensional (4D) flow magnetic resonance imaging (MRI). 4D Flow MRI was performed on a healthy adult and a child with double-aortic arch. The aortic lumen was segmented to visualize the blood flow. The CFD analyses were performed for the same geometries based on three turbulent models: laminar, large eddy simulation (LES), and the renormalization group k-ε model (RNG k-ε). The flow-velocity vector components, namely the wall shear stress (WSS) and flow energy loss (EL), of the MRI and CFD results were compared. The flow rate of the MRI results was underestimated in small vessels, including the neck vessels. Spiral flow in the ascending aorta caused by the left ventricular twist was observed by MRI. Secondary flow distal to the aortic arch was well realized in both CFD and MRI. The average correlation coefficients of the velocity vector components of MRI and CFD for the child were the highest for the RNG k-ε model (0.530 in ascending aorta, 0.768 in the aortic arch, 0.584 in the descending aorta). The WSS and EL values of MRI were less than half of those of CFD, but the WSS distribution patterns were quite similar. The WSS and EL estimates were higher in RNG k-ε and LES than in the laminar model because of eddy viscosity. The CFD computation realized accurate flow distal to the aortic arch, and the WSS distribution was well simulated compared to actual measurement using 4D Flow MRI. However, the helical flow was not simulated in the ascending aorta. The accuracy was enhanced by using the turbulence model, and the RNG k-ε model showed the highest correlation with 4D Flow MRI.


Assuntos
Aorta Torácica/diagnóstico por imagem , Velocidade do Fluxo Sanguíneo/fisiologia , Simulação por Computador , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Modelos Cardiovasculares , Estresse Mecânico , Aorta Torácica/fisiologia , Feminino , Voluntários Saudáveis , Humanos , Pessoa de Meia-Idade
10.
Heart Vessels ; 32(9): 1123-1129, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28389690

RESUMO

Mitral valve morphology after mitral valve surgery affects postoperative intraventricular flow patterns and long-term cardiac performance. We visualized ventricular flow by echocardiography vector flow mapping (VFM) to reveal the impact of different mitral valve procedures. Eleven cases of mechanical mitral valve replacement (nine in the anti-anatomical and two in the anatomical position), three bioprosthetic mitral valve replacements, and four mitral valve repairs were evaluated. The mean age at the procedure was 57.4 ± 17.8 year, and the echocardiography VFM in the apical long-axis view was performed 119.9 ± 126.7 months later. Flow energy loss (EL), kinetic pressure (KP), and the flow energy efficiency ratio (EL/KP) were measured. The cases with MVR in the anatomical position and with valve repair had normal vortex directionality ("Clockwise"; N = 6), whereas those with MVR in the anti-anatomical position and with a bioprosthetic mitral valve had the vortex in the opposite direction ("Counterclockwise"; N = 12). During diastole, vortex direction had no effect on EL ("Clockwise": 0.080 ± 0.025 W/m; "Counterclockwise": 0.083 ± 0.048 W/m; P = 0.31) or KP ("Clockwise": 0.117 ± 0.021 N; "Counterclockwise": 0.099 ± 0.057 N; P = 0.023). However, during systole, the EL/KP ratio was significantly higher in the "Counterclockwise" vortex than that in the "Clockwise" vortex (1.056 ± 0.463 vs. 0.617 ± 0.158; P = 0.009). MVP and MVR with a mechanical valve in the anatomical position preserve the physiological vortex, whereas MVR with a mechanical valve in the anti-anatomical position and a bioprosthetic mitral valve generate inefficient vortex flow patterns, resulting in a potential increase in excessive cardiac workload.


Assuntos
Bioprótese , Velocidade do Fluxo Sanguíneo/fisiologia , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Ventrículos do Coração/diagnóstico por imagem , Insuficiência da Valva Mitral/diagnóstico , Valva Mitral/diagnóstico por imagem , Diástole , Ecocardiografia , Feminino , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/fisiopatologia , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/fisiopatologia , Sístole
11.
Heart Vessels ; 32(11): 1364-1374, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28634695

RESUMO

Assessment of left ventricular (LV) dysfunction is vital in patients with repaired tetralogy of Fallot (rTOF). The early diastolic intraventricular pressure gradient (IVPG) in the LV plays an important role in diastolic function. IVPG is calculated as the intraventricular pressure difference divided by the LV length, which allows to account for differences in LV size and therefore calculate IVPG in children. We aimed to investigate the mechanisms of LV diastolic dysfunction by measuring mid-to-apical IVPG as an indicator of the active suction force sucking blood from the left atrium into the LV. We included 38 rTOF patients and 101 healthy controls. The study population was stratified based on age group into children (4-9 years), adolescents (10-15 years), and adults (16-40 years). IVPGs were calculated based on mitral inflow measurements obtained using color M-mode Doppler echocardiography. Although total IVPGs did not differ between rTOF patients and controls, mid-to-apical IVPGs in adolescents and adults were smaller among rTOF patients than among controls (0.15 ± 0.05 vs. 0.21 ± 0.06 mmHg/cm, p < 0.05; 0.09 ± 0.07 vs. 0.17 ± 0.05 mmHg/cm, p < 0.001; respectively). Additionally, only mid-to-apical IVPG correlated linearly with peak circumferential strain (ρ = 0.217, p = 0.011), longitudinal strain (ρ = -0.231, p = 0.006), torsion (ρ = -0.200, p = 0.018), and untwisting rate in early diastole (ρ = -0.233, p = 0.006). In rTOF, the mechanisms underlying diastolic dysfunction involve reduced active suction force, which correlates with reduced LV deformation in all directions.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Ventrículos do Coração/fisiopatologia , Tetralogia de Fallot/fisiopatologia , Função Ventricular Esquerda/fisiologia , Pressão Ventricular/fisiologia , Adolescente , Adulto , Criança , Pré-Escolar , Ecocardiografia Doppler , Feminino , Seguimentos , Ventrículos do Coração/diagnóstico por imagem , Humanos , Masculino , Período Pós-Operatório , Estudos Prospectivos , Tetralogia de Fallot/diagnóstico , Tetralogia de Fallot/cirurgia , Fatores de Tempo , Adulto Jovem
12.
Cardiovasc Ultrasound ; 15(1): 27, 2017 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-29241451

RESUMO

BACKGROUND: Staged palliative surgery markedly shifts the balance of volume load on a single ventricle and pulmonary vascular bed. Blalock-Taussig shunt necessitates a single ventricle eject blood to both the systemic and pulmonary circulation. On the contrary, bidirectional cavopulmonary shunt release the single ventricle from pulmonary circulation. CASE PRESENTATION: We report a case of tricuspid atresia patient who underwent first palliative surgery and second palliative surgery. Volume loading condition was assessed by energetic parameters (energy loss, kinetic energy) intraoperatively using vector flow mapping. These energetic parameters can simply indicate the volume loading condition. CONCLUSION: Vector flow mapping was useful tool for monitoring volume loading condition in congenital heart disease surgery.


Assuntos
Técnica de Fontan , Cuidados Paliativos , Atresia Tricúspide/diagnóstico por imagem , Atresia Tricúspide/cirurgia , Ecocardiografia Doppler em Cores , Humanos , Recém-Nascido , Masculino , Vetorcardiografia
14.
Heart Lung Circ ; 26(10): 1105-1112, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28131775

RESUMO

BACKGROUND: To investigate the results of off-pump coronary artery grafting (OPCAB) with the proximal suture device (PSD) regarding postoperative stroke and graft patency. METHODS: The PSD was used in 376 patients (32.0%), aorta-no-touch OPCAB was performed in 523 patients (45.2%), on-pump beating coronary artery bypass surgery (CABG) (on-beat group) in 125 patients (10.6%) including 51 conversions (conversion rate: 5.4%), and CABG with aortic clamp use (clamp group) in 152 patients. In the PSD group, Enclose II was used in 267 patients (71.0%). RESULTS: The hospital mortality rate was 1.95%. There was no early stroke in the OPCAB group, whereas the early-stroke rate was 0.8% in the on-beat group and 2.6% in the clamp group. The incidences of stroke at one month were: PSD group, 1.6%; no-touch group, 1.1%; on-beat group, 1.6%; and clamp group, 4.6% (p=0.014). The rates of complete revascularisation were higher in the PSD and clamp groups (94.7 and 94.0%, respectively) compared with the no-touch and on-beat groups (81.5 and 84.9%, respectively; p<0.001). The vein graft patency rates were comparable between the PSD and clamp groups. In multiple logistic regression analysis, OPCAB using the PSD did not increase the risk of stroke compared with the no-touch group (adjusted odds ratio [AOR]: 1.40; p=0.594) or on-beat group (AOR: 0.99; p=0.206), but reduced the risk of stroke compared with the clamp group (AOR: 0.19; p=0.005). CONCLUSIONS: Off-pump coronary artery grafting using the PSD was a safe and effective procedure. It led to lower incidences of postoperative stroke and excellent rates of graft patency and complete revascularisation compared with conventional CABG.


Assuntos
Ponte de Artéria Coronária sem Circulação Extracorpórea/métodos , Isquemia Miocárdica/cirurgia , Complicações Pós-Operatórias/prevenção & controle , Medição de Risco , Acidente Vascular Cerebral/prevenção & controle , Técnicas de Sutura/instrumentação , Suturas , Idoso , Ponte de Artéria Coronária , Feminino , Humanos , Incidência , Japão/epidemiologia , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia
15.
Wound Repair Regen ; 24(1): 189-94, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26464025

RESUMO

Infection during critical limb ischemia (CLI) is a challenging issue. Plasma presepsin is a novel biomarker for infection, which is related to bacterial phagocytosis by macrophages. The purpose of this study was to investigate the validity of presepsin as an indicator and predictor for early detection of infectious CLI. A retrospective observational study was conducted among 20 CLI patients (Rutherford 5 and 6) on hemodialysis (HD). Twenty CLI patients on HD (mean age 70.7 ± 5.6 years, male 85%) and 15 healthy patients on HD without CLI and infection (control group) were analyzed. All CLI patients received appropriate revascularization and plastic surgical treatment. CLI patients were classified into two groups: the healing group with complete epithelialization without discharge and the nonhealing group with infection signs. Plasma presepsin was measured and compared among the two groups and the control group using an automated immunoanalyzer, PATHFAST, based on a noncompetitive chemiluminescent enzyme immunoassay. The median plasma presepsin and its interquartile range were 1,320 (1,055-1,465) pg/mL in the control group, 1,320 (1,050-1,613) pg/mL in the healing group and 3,193 (2,519-3,832) pg/mL in the nonhealing group. The plasma presepsin concentrations were significantly higher in the nonhealing group compared with the control group (p < 0.001) and the healing group (p < 0.01). A receiver operating characteristic curve analysis revealed that presepsin had highest accuracy (0.979) among various inflammatory markers, including C-reactive protein and the white blood cell count. The diagnostic cutoff value of 2,083 pg/mL was able to distinguish the nonhealing group and healing group with a sensitivity of 100% and a specificity of 88.9%. Our results suggest that plasma presepsin may be useful for predicting "critical colonization" and "infection" in nonhealing CLI in HD patients, therefore, the definitive cutoff value may be used for determinating the indication for reintervention and/or major limb amputation.


Assuntos
Isquemia/cirurgia , Falência Renal Crônica/terapia , Receptores de Lipopolissacarídeos/sangue , Extremidade Inferior/cirurgia , Fragmentos de Peptídeos/sangue , Doença Arterial Periférica/cirurgia , Diálise Renal , Infecção da Ferida Cirúrgica/sangue , Ferida Cirúrgica/sangue , Procedimentos Cirúrgicos Vasculares , Idoso , Biomarcadores/sangue , Feminino , Humanos , Isquemia/complicações , Falência Renal Crônica/complicações , Extremidade Inferior/irrigação sanguínea , Masculino , Doença Arterial Periférica/complicações , Curva ROC , Estudos Retrospectivos , Sensibilidade e Especificidade , Cicatrização
16.
Heart Vessels ; 31(5): 643-8, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-25910614

RESUMO

For coronary artery bypass grafting (CABG), free grafts such as a saphenous vein or radial artery are often used for grafts to the lateral and posterior walls. However, the relationship between top-end anastomosis design and long-term patency remains unknown. Because coronary artery blood flow is dominant during diastole, top-end anastomosis may work better if the graft is directed towards the apex, whereas the shortest graft pathway appears to be most efficient. Using computational fluid dynamic models, we evaluated the hemodynamic variables that were affected by the angle of the top-end anastomosis. We created three-dimensional geometries of the aortic root with coronary arteries that involved 75 % stenosis in the obtuse marginal and postero-lateral branches. Two bypass models under vasodilator administration were created: in a"Model A", the top-end anastomosis is parallel to the long axis of the ascending aorta and the graft passed over the conus directed towards the apex; in a "Model B", the top-end anastomosis is directed toward the shortest pathway, and form near the right angles to the long axis of the ascending aorta. Wall shear stress (WSS) and its fluctuation, an oscillatory shear index (OSI) were evaluated to predict fibrosis progression at the anastomosis site and graft flow. Graft flow was 197.3 ml/min and 207.3 ml/min in the "Model A" and "Model B", respectively. The minimal WSS value inside the graft with the "Model A" and "Model B" was 0.53 Pa and 4.09 Pa, respectively, and the OSI value was 0.46 and 0.04, respectively. The top-end anastomosis of a free graft should be directed vertically towards the aorta to achieve the shortest graft pathway to maintain a high graft flow rate and to avoid the risks of endothelial fibrosis and plaque progression over the long-term after CABG.


Assuntos
Ponte de Artéria Coronária/métodos , Circulação Coronária , Estenose Coronária/cirurgia , Vasos Coronários/cirurgia , Grau de Desobstrução Vascular , Anastomose Cirúrgica , Velocidade do Fluxo Sanguíneo , Simulação por Computador , Ponte de Artéria Coronária/efeitos adversos , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/patologia , Estenose Coronária/fisiopatologia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Vasos Coronários/fisiopatologia , Progressão da Doença , Células Endoteliais/patologia , Fibrose , Humanos , Modelos Cardiovasculares , Placa Aterosclerótica , Índice de Gravidade de Doença , Estresse Mecânico , Resultado do Tratamento
18.
Int Heart J ; 57(4): 449-55, 2016 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-27385601

RESUMO

The use of measured data as boundary conditions renders hemodynamic simulations more patient-specific. However, synchronized acquisition of data at multiple locations is often difficult in clinical practice. This study proposes a method for resynchronizing measured data for use as boundary conditions for flow simulations using frequency analyses, and discusses the optimal cut-off frequency for differentiating cardiac and respiratory variation in hemodynamic data during resynchronization. To demonstrate the utility of the method, a Fontan circulation, which is the final palliative result with single-ventricle physiology, was used. The results suggest that it is optimal to set a cut-off frequency that gives a local minimum in the power spectrum that is slightly lower than the peak frequency of the heartbeat. Additionally, the total energy loss depended on the cut-off frequency, although the overall flow patterns appeared to be similar. The method is applicable to cardiovascular systems other than the Fontan circulation, where hemodynamic data with multifactorial fluctuations are required at various locations but simultaneous measurements are not possible.


Assuntos
Simulação por Computador , Técnica de Fontan , Hemodinâmica , Ventilação Monopulmonar , Desenho de Equipamento , Humanos , Modelos Cardiovasculares , Ventilação Monopulmonar/métodos
19.
Int Heart J ; 57(1): 121-2, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26673438

RESUMO

Trisomy 13 is associated with a variety of congenital anomalies, some of which are life-threatening and related to poor prognosis. Therefore, cardiac surgery is rarely offered to these patients, especially to those with complex cardiac anomalies. We report the case of a neonate weighing 2324 g who was born with severe congenital heart defects. Transthoracic echocardiography revealed the diagnoses of asplenia, single ventricle, aortic stenosis, coarctation of the aorta, hypoplastic aortic arch, and total anomalous pulmonary venous return. She was hemodynamically unstable. Palliative Norwood procedure with right ventricle-pulmonary artery conduit (RV-PA conduit) was performed at the age of 1 day to save her life. On postoperative day 7, chromosome analysis revealed trisomy 13. Echocardiography revealed good heart function; stable hemodynamic status was achieved with minimal amounts of inotropic agents. However, she developed anuria, which did not improve despite situational possible interventions, including peritoneal dialysis and continuous hemodiafiltration. On postoperative day 37, she succumbed to sudden cardiorespiratory failure. Nevertheless, this case indicates that a neonate with trisomy 13 can have a better chance at survival with cardiac surgery such as the Norwood procedure with an RV-PA conduit.


Assuntos
Transtornos Cromossômicos/cirurgia , Procedimentos de Norwood/métodos , Cateterismo Cardíaco , Transtornos Cromossômicos/diagnóstico , Cromossomos Humanos Par 13 , Ecocardiografia , Feminino , Humanos , Recém-Nascido , Resultado do Tratamento , Trissomia/diagnóstico , Síndrome da Trissomia do Cromossomo 13
20.
Heart Vessels ; 30(1): 56-60, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24213974

RESUMO

The low arterial oxygen saturation (SaO2) after bidirectional cavopulmonary shunt (BCPS) predicts poor prognosis. The venous oxygen saturation of inferior vena cava (SivcO2), as well as the pulmonary blood flow/systemic blood flow ratio (Q p/Q s) affects the SaO2. The purpose of this study is to determine whether SivcO2 or Q p/Q s should be increased to achieve better outcomes after BCPS. Forty-eight patients undergoing BCPS were included. Data of patients' age and body weight, SivcO2, Q p/Q s, pulmonary artery (PA) pressure and resistance, PA area index, morphology of ventricle, atrioventricular valve regurgitation, and history of PA plasty were collected. Stepwise multiple logistic regression analyses were used to investigate which of the factors most affected the SaO2 after BCPS. There was a significant correlation between SivcO2 and SaO2 (r = 0.771, P < 0.00001). There was no strong correlation between Q p/Q s and SaO2 (r = 0.358, P < 0.05). Stepwise multiple logistic regression analyses revealed that both SivcO2 (r = 0.49, 95 % confidence interval (CI) 0.37-0.62, P < 0.0001) and Q p/Q s (r = 11.1, 95 % CI 3.3-18.9, P = 0.007) most affected SaO2 after BCPS. Since the SivcO2 has a stronger correlation than Q p/Q s with SaO2, despite the fact that both raising Q p/Q s and raising cardiac output can increase SaO2, raising cardiac output should be considered prior to Q p/Q s to raise the SaO2 after BCPS.


Assuntos
Débito Cardíaco , Técnica de Fontan/métodos , Ventrículos do Coração/anatomia & histologia , Oxigênio/sangue , Oxigênio/uso terapêutico , Pré-Escolar , Feminino , Humanos , Lactente , Modelos Logísticos , Masculino , Prognóstico , Artéria Pulmonar/fisiologia , Resultado do Tratamento , Veia Cava Inferior/fisiologia
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa