Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 81
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Clin Transplant ; 37(1): e14833, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36335571

RESUMO

INTRODUCTION: In 2018, the United Network for Organ Sharing (UNOS) implemented a new heart allocation system which prioritized patients on temporary support devices and left-ventricular assist device (LVAD) patients with complications. These changes have the potential to impact outcomes for patients bridged to transplant with an LVAD. METHODS: We performed a retrospective study of 168 adult heart transplant recipients at our center between 2016 and 2020 evaluating post-transplant outcomes before and after UNOS allocation changes. Donor and recipient data were retrieved from chart review and national databases. The primary outcome of this study was severe primary graft dysfunction (PGD) with secondary outcomes of 30-day readmission, 30-day mortality, and 1-year mortality. RESULTS: Incidence of severe PGD was similar in the overall cohort before and after the changes (10% vs. 15%, respectively, p = .3) and increased in the LVAD-bridged cohort (12% vs. 40%, respectively, p < .01). Secondary outcomes of readmission and survival were similar between all groups. Blood transfusion was predictive of severe PGD in multivariable modeling (OR 1.3 [1.11-1.59], p < .01).


Assuntos
Insuficiência Cardíaca , Transplante de Coração , Coração Auxiliar , Disfunção Primária do Enxerto , Adulto , Humanos , Transplante de Coração/efeitos adversos , Estudos Retrospectivos , Coração Auxiliar/efeitos adversos , Disfunção Primária do Enxerto/epidemiologia , Disfunção Primária do Enxerto/etiologia , Resultado do Tratamento
2.
N Engl J Med ; 380(17): 1618-1627, 2019 04 25.
Artigo em Inglês | MEDLINE | ID: mdl-30883052

RESUMO

BACKGROUND: In two interim analyses of this trial, patients with advanced heart failure who were treated with a fully magnetically levitated centrifugal-flow left ventricular assist device were less likely to have pump thrombosis or nondisabling stroke than were patients treated with a mechanical-bearing axial-flow left ventricular assist device. METHODS: We randomly assigned patients with advanced heart failure to receive either the centrifugal-flow pump or the axial-flow pump irrespective of the intended goal of use (bridge to transplantation or destination therapy). The composite primary end point was survival at 2 years free of disabling stroke or reoperation to replace or remove a malfunctioning device. The principal secondary end point was pump replacement at 2 years. RESULTS: This final analysis included 1028 enrolled patients: 516 in the centrifugal-flow pump group and 512 in the axial-flow pump group. In the analysis of the primary end point, 397 patients (76.9%) in the centrifugal-flow pump group, as compared with 332 (64.8%) in the axial-flow pump group, remained alive and free of disabling stroke or reoperation to replace or remove a malfunctioning device at 2 years (relative risk, 0.84; 95% confidence interval [CI], 0.78 to 0.91; P<0.001 for superiority). Pump replacement was less common in the centrifugal-flow pump group than in the axial-flow pump group (12 patients [2.3%] vs. 57 patients [11.3%]; relative risk, 0.21; 95% CI, 0.11 to 0.38; P<0.001). The numbers of events per patient-year for stroke of any severity, major bleeding, and gastrointestinal hemorrhage were lower in the centrifugal-flow pump group than in the axial-flow pump group. CONCLUSIONS: Among patients with advanced heart failure, a fully magnetically levitated centrifugal-flow left ventricular assist device was associated with less frequent need for pump replacement than an axial-flow device and was superior with respect to survival free of disabling stroke or reoperation to replace or remove a malfunctioning device. (Funded by Abbott; MOMENTUM 3 ClinicalTrials.gov number, NCT02224755.).


Assuntos
Insuficiência Cardíaca/terapia , Coração Auxiliar , Desenho de Prótese , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Intervalo Livre de Doença , Feminino , Coração Auxiliar/efeitos adversos , Humanos , Análise de Intenção de Tratamento , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Falha de Prótese , Reoperação/estatística & dados numéricos , Acidente Vascular Cerebral/etiologia
3.
J Card Surg ; 37(1): 76-83, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34634155

RESUMO

BACKGROUND: Machine learning (ML) can identify nonintuitive clinical variable combinations that predict clinical outcomes. To assess the potential predictive contribution of standardized Society of Thoracic Surgeons (STS) Database clinical variables, we used ML to detect their association with repair durability in ischemic mitral regurgitation (IMR) patients in a single institution study. METHODS: STS Database variables (n = 53) served as predictors of repair durability in ML modeling of 224 patients who underwent surgical revascularization and mitral valve repair for IMR. Follow-up mortality and echocardiography data allowed 1-year outcome analysis in 173 patients. Supervised ML analyses were performed using recurrence (≥3+ IMR) or death versus nonrecurrence (<3+ IMR) as the binary outcome classification. RESULTS: We tested standard ML and deep learning algorithms, including support vector machines, logistic regression, and deep neural networks. Following training, final models were utilized to predict class labels for the patients in the test set, producing receiver operating characteristic (ROC) curves. The three models produced similar area under the curve (AUC), and predicted class labels with promising accuracy (AUC = 0.72-0.75). CONCLUSIONS: Readily-available STS Database variables have potential to play a significant role in the development of ML models to direct durable surgical therapy in IMR patients.


Assuntos
Anuloplastia da Valva Mitral , Insuficiência da Valva Mitral , Isquemia Miocárdica , Humanos , Aprendizado de Máquina , Insuficiência da Valva Mitral/cirurgia , Isquemia Miocárdica/complicações , Isquemia Miocárdica/cirurgia , Resultado do Tratamento
4.
N Engl J Med ; 378(15): 1386-1395, 2018 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-29526139

RESUMO

BACKGROUND: In an early analysis of this trial, use of a magnetically levitated centrifugal continuous-flow circulatory pump was found to improve clinical outcomes, as compared with a mechanical-bearing axial continuous-flow pump, at 6 months in patients with advanced heart failure. METHODS: In a randomized noninferiority and superiority trial, we compared the centrifugal-flow pump with the axial-flow pump in patients with advanced heart failure, irrespective of the intended goal of support (bridge to transplantation or destination therapy). The composite primary end point was survival at 2 years free of disabling stroke (with disabling stroke indicated by a modified Rankin score of >3; scores range from 0 to 6, with higher scores indicating more severe disability) or survival free of reoperation to replace or remove a malfunctioning device. The noninferiority margin for the risk difference (centrifugal-flow pump group minus axial-flow pump group) was -10 percentage points. RESULTS: Of 366 patients, 190 were assigned to the centrifugal-flow pump group and 176 to the axial-flow pump group. In the intention-to-treat population, the primary end point occurred in 151 patients (79.5%) in the centrifugal-flow pump group, as compared with 106 (60.2%) in the axial-flow pump group (absolute difference, 19.2 percentage points; 95% lower confidence boundary, 9.8 percentage points [P<0.001 for noninferiority]; hazard ratio, 0.46; 95% confidence interval [CI], 0.31 to 0.69 [P<0.001 for superiority]). Reoperation for pump malfunction was less frequent in the centrifugal-flow pump group than in the axial-flow pump group (3 patients [1.6%] vs. 30 patients [17.0%]; hazard ratio, 0.08; 95% CI, 0.03 to 0.27; P<0.001). The rates of death and disabling stroke were similar in the two groups, but the overall rate of stroke was lower in the centrifugal-flow pump group than in the axial-flow pump group (10.1% vs. 19.2%; hazard ratio, 0.47; 95% CI, 0.27 to 0.84, P=0.02). CONCLUSIONS: In patients with advanced heart failure, a fully magnetically levitated centrifugal-flow pump was superior to a mechanical-bearing axial-flow pump with regard to survival free of disabling stroke or reoperation to replace or remove a malfunctioning device. (Funded by Abbott; MOMENTUM 3 ClinicalTrials.gov number, NCT02224755 .).


Assuntos
Insuficiência Cardíaca/terapia , Coração Auxiliar , Desenho de Prótese , Adulto , Idoso , Idoso de 80 Anos ou mais , Pressão Sanguínea , Feminino , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Coração Auxiliar/efeitos adversos , Humanos , Análise de Intenção de Tratamento , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Qualidade de Vida , Reoperação/estatística & dados numéricos , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/mortalidade , Trombose/etiologia , Resultado do Tratamento , Teste de Caminhada
5.
J Card Fail ; 27(3): 327-337, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33347997

RESUMO

BACKGROUND: Venoarterial extracorporeal membrane oxygenation (VA-ECMO) is increasingly used as a life-saving therapy for patients with cardiovascular collapse, but identifying patients unlikely to benefit remains a challenge. METHODS AND RESULTS: We created the RESCUE registry, a retrospective, observational registry of adult patients treated with VA-ECMO between January 2007 and June 2017 at 3 high-volume centers (Columbia University, Duke University, and Washington University) to describe short-term patient outcomes. In 723 patients treated with VA-ECMO, the most common indications for deployment were postcardiotomy shock (31%), cardiomyopathy (including acute heart failure) (26%), and myocardial infarction (17%). Patients frequently suffered in-hospital complications, including acute renal dysfunction (45%), major bleeding (41%), and infection (33%). Only 40% of patients (n = 290) survived to discharge, with a minority receiving durable cardiac support (left ventricular assist device [n = 48] or heart transplantation [n = 7]). Multivariable regression analysis identified risk factors for mortality on ECMO as older age (odds ratio [OR], 1.26; 95% confidence interval [CI], 1.12-1.42) and female sex (OR, 1.44; 95% CI, 1.02-2.02) and risk factors for mortality after decannulation as higher body mass index (OR 1.17; 95% CI, 1.01-1.35) and major bleeding while on ECMO support (OR, 1.92; 95% CI, 1.23-2.99). CONCLUSIONS: Despite contemporary care at high-volume centers, patients treated with VA-ECMO continue to have significant in-hospital morbidity and mortality. The optimization of outcomes will require refinements in patient selection and improvement of care delivery.


Assuntos
Oxigenação por Membrana Extracorpórea , Insuficiência Cardíaca , Adulto , Idoso , Oxigenação por Membrana Extracorpórea/efeitos adversos , Feminino , Humanos , Sistema de Registros , Estudos Retrospectivos , Choque Cardiogênico/epidemiologia , Choque Cardiogênico/terapia
6.
Clin Transplant ; 35(12): e14471, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34546591

RESUMO

BACKGROUND: Previous studies in heart transplantation have shown an association between institutional case volume and outcomes. We aim to determine the case volume associated with optimal 1-year survival after transplantation. METHODS AND RESULTS: The United Network for Organ Sharing (UNOS) national database was analyzed for adult patients who underwent orthotopic heart transplantation between January 2013 and December 2017. A total of 11,196 cases at 128 transplant centers were included. Risk-adjusted restricted cubic splines revealed a non-linear association between institutional case volume and 1-year post-transplant survival. In the risk-adjusted, random-effect Cox model with segmented linear splines, higher heart transplant volume up to 24 cases per year was associated with better 1-year survival (HR = .978 every additional case, 95% CI .963-.993), and optimal survival was maintained between 24 and 38 cases per year. However, further increase in volume above 38 transplants per year was associated with mildly decreased 1-year survival (HR = 1.007 every additional case, 95% CI 1.002-1.013). CONCLUSIONS: The relationship between institutional case volume and heart transplant 1-year survival is non-linear, with optimal survival observed at institutional case volume of 24-38 cases per year.


Assuntos
Transplante de Coração , Adulto , Bases de Dados Factuais , Sobrevivência de Enxerto , Humanos , Modelos de Riscos Proporcionais , Sistema de Registros , Estudos Retrospectivos , Resultado do Tratamento
7.
Clin Transplant ; 35(6): e14296, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33759249

RESUMO

Acute kidney injury is a common complication following heart transplantation, and the factors contributing to acute kidney injury are not well understood. We conducted a retrospective cohort study evaluating patients who underwent heart transplantation between 2009 and 2016 at a single institution. The primary endpoint was incidence of acute kidney injury as defined by Kidney Disease Improving Global Outcomes criteria. Secondary endpoints included 30-day hospital readmission, 30-day mortality, and 1-year mortality. A total of 228 heart transplant patients were included in the study for analysis. In total, 145 (64%) developed acute kidney injury, where 43 (30%) were classified as stage I, 28 (19%) as stage II, and 74 (51%) as stage III. Risk factors found to be associated with the presence of acute kidney injury included increased use of vasopressors and inotropes post-transplant. Protective factors included cardiopulmonary bypass time <170 min. Acute kidney injury was found to be associated with increased 30-day and 1-year mortality.


Assuntos
Injúria Renal Aguda , Transplante de Coração , Injúria Renal Aguda/epidemiologia , Injúria Renal Aguda/etiologia , Transplante de Coração/efeitos adversos , Humanos , Incidência , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Fatores de Risco
8.
N Engl J Med ; 376(5): 440-450, 2017 02 02.
Artigo em Inglês | MEDLINE | ID: mdl-27959709

RESUMO

BACKGROUND: Continuous-flow left ventricular assist systems increase the rate of survival among patients with advanced heart failure but are associated with the development of pump thrombosis. We investigated the effects of a new magnetically levitated centrifugal continuous-flow pump that was engineered to avert thrombosis. METHODS: We randomly assigned patients with advanced heart failure to receive either the new centrifugal continuous-flow pump or a commercially available axial continuous-flow pump. Patients could be enrolled irrespective of the intended goal of pump support (bridge to transplantation or destination therapy). The primary end point was a composite of survival free of disabling stroke (with disabling stroke indicated by a modified Rankin score >3; scores range from 0 to 6, with higher scores indicating more severe disability) or survival free of reoperation to replace or remove the device at 6 months after implantation. The trial was powered for noninferiority testing of the primary end point (noninferiority margin, -10 percentage points). RESULTS: Of 294 patients, 152 were assigned to the centrifugal-flow pump group and 142 to the axial-flow pump group. In the intention-to-treat population, the primary end point occurred in 131 patients (86.2%) in the centrifugal-flow pump group and in 109 (76.8%) in the axial-flow pump group (absolute difference, 9.4 percentage points; 95% lower confidence boundary, -2.1 [P<0.001 for noninferiority]; hazard ratio, 0.55; 95% confidence interval [CI], 0.32 to 0.95 [two-tailed P=0.04 for superiority]). There were no significant between-group differences in the rates of death or disabling stroke, but reoperation for pump malfunction was less frequent in the centrifugal-flow pump group than in the axial-flow pump group (1 [0.7%] vs. 11 [7.7%]; hazard ratio, 0.08; 95% CI, 0.01 to 0.60; P=0.002). Suspected or confirmed pump thrombosis occurred in no patients in the centrifugal-flow pump group and in 14 patients (10.1%) in the axial-flow pump group. CONCLUSIONS: Among patients with advanced heart failure, implantation of a fully magnetically levitated centrifugal-flow pump was associated with better outcomes at 6 months than was implantation of an axial-flow pump, primarily because of the lower rate of reoperation for pump malfunction. (Funded by St. Jude Medical; MOMENTUM 3 ClinicalTrials.gov number, NCT02224755 .).


Assuntos
Insuficiência Cardíaca/terapia , Coração Auxiliar , Adulto , Idoso , Idoso de 80 Anos ou mais , Intervalo Livre de Doença , Insuficiência Cardíaca/mortalidade , Coração Auxiliar/efeitos adversos , Humanos , Análise de Intenção de Tratamento , Estimativa de Kaplan-Meier , Pessoa de Meia-Idade , Desenho de Prótese , Falha de Prótese , Acidente Vascular Cerebral/etiologia , Trombose/etiologia , Adulto Jovem
9.
Clin Transplant ; 34(1): e13768, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31833584

RESUMO

BACKGROUND: Primary graft dysfunction (PGD) and acute cellular rejection (ACR) are important causes of early morbidity and mortality following lung and heart transplantation. While many studies have elucidated donor-related risk factors of PGD and ACR, these complications often occur even with "ideal" donors. Therefore, we investigated potential associations of PGD and ACR between bilateral lung and heart transplant recipients from the same multiorgan donor, respectively. METHODS: Between 2011 and 2017, 100 donors contributed 100 bilateral lung transplants and 100 heart transplants performed. Logistic regression analysis for PGD and Cox proportional hazards regression analysis for ACR were used to estimate the relationship of heart and lung transplants. RESULTS: The incidence of PGD was 33% among lung and 17% among heart transplant recipients. Similarly, the incidence of ACR grade ≥ A2 for lung recipients was 38% (30/80), and the incidence of ACR grade ≥ 2R for heart recipients was 19% (15/80). There was no association between the development of PGD and ACR in lung and heart transplant recipients from the same donor, respectively. CONCLUSIONS: These findings suggest that inherent donor factors are not critical to the development of PGD and ACR after lung and heart transplantation.


Assuntos
Transplante de Coração , Transplante de Pulmão , Obtenção de Tecidos e Órgãos , Transplante de Coração/efeitos adversos , Humanos , Pulmão , Transplante de Pulmão/efeitos adversos , Estudos Retrospectivos , Doadores de Tecidos , Transplantados
10.
J Card Surg ; 35(10): 2512-2521, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32789912

RESUMO

INTRODUCTION: Venoarterial extracorporeal membrane oxygenation (VA-ECMO) is utilized as a life-saving procedure and bridge to myocardial recovery for patients in refractory cardiogenic shock. Despite technical advancements, VA-ECMO retains high mortality. This study aims to identify the clinical predictors of in-hospital mortality after VA-ECMO to improve risk stratification for this tenuous patient population. METHODS: The REgistry for Cardiogenic Shock: Utility and Efficacy of Device Therapy database is a multicenter, observational registry of ECMO patients. From 2013 to 2018, 789 patients underwent VA-ECMO. Bivariate analysis was performed on more than 300 variables regarding their association with in-hospital mortality. Logistic regression analyses were performed with variables chosen based upon clinical and statistical significance in the bivariate analysis. Tests were considered significant at a two-sided P < .05. RESULTS: Although 63.5% patients were successfully weaned from VA-ECMO, in-hospital mortality was 57.9%. Nonsurvivors were older (P < .0001), had higher body mass index (P = .01), higher rates of hypertension (P = .02), coronary artery disease (P = .02), chronic obstructive pulmonary disease (P = .02), chronic liver disease (P = .008), percutaneous coronary intervention (P = .02), and surgical revascularization (P = .02). Multivariate predictors for in-hospital mortality include older age (odds ratio [OR], 1.019; P = .007), cardiac arrest (OR, 2.76; P = .006), chronic liver disease (OR, 8.87; P = .04), elevated total bilirubin (OR, 1.093; P < .0001), and the presence of a left ventricular vent (OR, 2.018; P = .03). Pre-ECMO sinus rhythm was protective (OR, 0.374; P = .006). CONCLUSIONS: In a large study of recent VA-ECMO patients, in-hospital mortality remains significant, but acceptable given the severe pathology manifested in this population. Identification of pre-ECMO predictors of mortality helps stratify high-risk patients when deciding on ECMO placement, prolonged support, and prognosis.


Assuntos
Oxigenação por Membrana Extracorpórea/mortalidade , Oxigenação por Membrana Extracorpórea/métodos , Mortalidade Hospitalar , Choque Cardiogênico/mortalidade , Choque Cardiogênico/terapia , Adulto , Fatores Etários , Idoso , Índice de Massa Corporal , Comorbidade , Doença da Artéria Coronariana/epidemiologia , Bases de Dados Factuais , Feminino , Humanos , Hipertensão/epidemiologia , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Doença Pulmonar Obstrutiva Crônica/epidemiologia , Risco , Choque Cardiogênico/epidemiologia
11.
Circulation ; 138(18): 1923-1934, 2018 10 30.
Artigo em Inglês | MEDLINE | ID: mdl-29807933

RESUMO

BACKGROUND: The MOMENTUM 3 trial compares the centrifugal HeartMate 3 (HM3) with the axial HeartMate II (HMII) continuous-flow left ventricular assist system in patients with advanced heart failure, irrespective of the intended goal of therapy. The trial's 2-year clinical outcome (n=366) demonstrated superiority of the HM3 for the primary end point (survival free of a disabling stroke or reoperation to replace or remove a malfunctioning pump). This analysis evaluates health resource use and cost implications of the observed differences between the 2 devices while patients were enrolled in the trial. METHODS: We analyzed all hospitalizations and their associated costs occurring after discharge from the implant hospitalization until censoring (study withdrawal, heart transplantation, and pump exchange with a nonstudy device or death). Each adjudicated episode of hospital-based care was used to calculate costs (device-attributable and non-device-attributable event costs), estimated by using trial data and payer administrative claims databases. Cost savings stratified by subgroups (study outcome [transplant, death, or ongoing on device], intended goal of therapy, type of insurance, or sex) were also assessed. RESULTS: In 366 randomly assigned patients, 361 comprised the as-treated group (189 in the HM3 group and 172 in the HMII group), of whom 337 (177 in the HM3 group and 160 in the HMII group) were successfully discharged following implantation. The HM3 arm experienced fewer total hospitalizations per patient-year (HM3: 2.1±0.2 versus HMII: 2.7±0.2; P=0.015) and 8.3 fewer hospital days per patient-year on average (HM3: 17.1 days versus HMII: 25.5 days; P=0.003). These differences were driven by patients hospitalized for suspected pump thrombosis (HM3: 0.6% versus HMII: 12.5%; P<0.001) and stroke (HM3: 2.8% versus HMII: 11.3%; P=0.002). Controlled for time spent in the study (average cumulative cost per patient-year), postdischarge HM3 arm costs were 51% lower than with the HMII (HM3: $37 685±4251 versus HMII: $76 599±11 889, P<0.001) and similar in either bridge to transplant or destination therapy intent. CONCLUSIONS: In this 2-year outcome economic analysis of the MOMENTUM 3 trial, the HM3 demonstrated a reduction in rehospitalizations, hospital days spent during rehospitalizations, and a significant cost savings following discharge in comparison with the HMII left ventricular assist system, irrespective of the intended goal of therapy. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov . Unique identifier: NCT02224755.


Assuntos
Atenção à Saúde/economia , Insuficiência Cardíaca/terapia , Coração Auxiliar/economia , Adulto , Idoso , Idoso de 80 Anos ou mais , Custos e Análise de Custo , Feminino , Insuficiência Cardíaca/economia , Insuficiência Cardíaca/patologia , Transplante de Coração , Coração Auxiliar/efeitos adversos , Hospitalização , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Índice de Gravidade de Doença , Acidente Vascular Cerebral/etiologia , Trombose/etiologia , Resultado do Tratamento , Adulto Jovem
12.
J Artif Organs ; 21(3): 359-362, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29502323

RESUMO

Although the incidence of driveline failure has been significantly reduced with the major modification to the driveline connection to the HeartMate II left ventricular assist device (LVAD), internal and external driveline damage continues to be a major reason for pump exchange or driveline repair. We report three cases of internal driveline damage under the costal margin and in the adjacent abdominal wall. All three cases developed occasional electrical disruptions 2-5 years after the original LVAD implant through the median sternotomy. Two patients underwent subcostal LVAD exchange and one had driveline externalization and repair. The driveline velour was well adhered to the costal margin and wire damage was found at the costal margin as well as the subsequent segment in the abdominal wall. Repeated ante-flex bending of the abdominal wall over years appeared to cause the chronic wear and tear of the vertically located driveline under the costal margin. This report will confirm a pitfall of the LVAD driveline location which can potentially cause driveline damage in the mid-to-long term.


Assuntos
Insuficiência Cardíaca/cirurgia , Coração Auxiliar/efeitos adversos , Falha de Prótese , Idoso , Feminino , Humanos , Masculino , Estudos Retrospectivos , Caixa Torácica/cirurgia , Esternotomia
13.
J Artif Organs ; 20(1): 42-49, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27830349

RESUMO

Current guidelines recommend adenosine diphosphate receptor inhibitors (ADPRi) be discontinued 5-7 days prior to cardiac surgery due to increased bleeding events, rates of re-exploration, and transfusions. However, the risks of left ventricular assist device (LVAD) implantation in patients taking an ADPRi have not previously been studied. We retrospectively identified 134 eligible patients with ischemic cardiomyopathy that underwent LVAD implantation between July 2009 and August 2013. The cohorts received an ADPRi ≤5 days of surgery (n = 25) versus >5 days prior or not at all (n = 109). Subgroup analyses adjusted for differences in frequency of redo sternotomy between cohorts, excluded patients that received an ADPRi >1 year prior to surgery, and excluded patients with a redo sternotomy. The ADPRi and control groups did not have significant differences in the primary outcomes, intraoperative PRBC units transfused (3.0 vs. 4.0, p = 0.12) or chest tube output within 24 h of surgery (1.66 L vs. 1.80 L, p = 0.61). After adjusting for differences in frequency of redo sternotomy (ADPRi vs. control, 12 vs. 52%, p ≤ 0.001), no significant difference in PRBC units transfused (3.1 vs. 3.5, p = 0.59) or chest tube output (2.04 L vs. 2.04 L, p = 0.98) was seen. No significant difference in 30-day mortality (8.0 vs. 11.0%, p = 0.63), 90-day mortality (16.4 vs. 23.3%, p = 0.42), or length of stay (29.0 vs. 28.0, p = 0.61) was seen. In this single-center experience, use of an ADPRi ≤5 days prior to LVAD implantation was not associated with increased bleeding, length of stay, or mortality.


Assuntos
Perda Sanguínea Cirúrgica/prevenção & controle , Insuficiência Cardíaca/terapia , Coração Auxiliar/efeitos adversos , Antagonistas do Receptor Purinérgico P2Y/efeitos adversos , Esternotomia , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Antagonistas do Receptor Purinérgico P2Y/uso terapêutico , Estudos Retrospectivos , Resultado do Tratamento , Suspensão de Tratamento
14.
Heart Vessels ; 31(7): 1186-95, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26563105

RESUMO

The details of valvular leaflet healing following valvuloplasty and leaflet perforation from endocarditis are poorly understood. In this study, the synthesis and turnover of valvular extracellular matrix due to healing of a critical sized wound was investigated. Twenty-nine sheep were randomized to either CTRL (n = 11) or HOLE (n = 18), in which a 2.8-4.8 mm diameter hole was punched in the posterior mitral leaflet. After 12 weeks, posterior leaflets were harvested and histologically stained to localize extracellular matrix components. Immunohistochemistry was also performed to assess matrix components and markers of matrix turnover. A semi-quantitative grading scale was used to quantify differences between HOLE and CTRL. After 12 weeks, the hole diameter was reduced by 71.3 ± 1.4 % (p < 0.001). Areas of remodeling surrounding the hole contained more activated cells, greater expression of proteoglycans, and markers of matrix turnover (prolyl 4-hydroxylase, metalloproteases, and lysyl oxidase, each p ≤ 0.025), along with fibrin accumulation. Two distinct remodeling regions were evident surrounding the hole, one directly bordering the hole rich in versican and hyaluronan and a second adjacent region with abundant collagen and elastic fiber turnover. The remodeling also caused reduced delineation between valve layers (p = 0.002), more diffuse staining of matrix components and markers of matrix turnover (p < 0.001), and disruption of the collagenous fibrosa. In conclusion, acute valve injury elicited distinct, heterogeneous alterations in valvular matrix composition and structure, resulting in partial wound closure. Because these changes could also affect leaflet mechanics and valve function, it will be important to determine their impact on healing wounds.


Assuntos
Matriz Extracelular/patologia , Valva Mitral/patologia , Cicatrização , Animais , Biomarcadores/metabolismo , Proliferação de Células , Matriz Extracelular/metabolismo , Proteínas da Matriz Extracelular/metabolismo , Imuno-Histoquímica , Valva Mitral/metabolismo , Valva Mitral/cirurgia , Modelos Animais , Ovinos , Fatores de Tempo
15.
JTCVS Tech ; 23: 63-71, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38351990

RESUMO

Objective: The Impella 5.5 (Abiomed, Inc), a surgically implanted endovascular microaxial left ventricular assist device, is increasingly used worldwide and there have been more than 10,000 implants. The purpose of this study is to describe a large-volume, single-center experience with the use of the Impella 5.5. Methods: Data were obtained retrospectively from patients supported with the Impella 5.5 implanted at our institution from May 1, 2020, to December 31, 2022. Demographic, operative, and postoperative outcomes for each group are described. Results are reported in median (interquartile range) or n (%). The entire cohort was divided into 5 main groups based on the intention to treat at the time of the Impella 5.5 implantation: (1) patients who had a planned Impella 5.5 implanted at the time of high-risk cardiac surgery; (2) patients with cardiogenic shock; (3) patients bridged to a durable left ventricular assist device; (4) patients bridged to transplant; and (5) patients with postcardiotomy shock who received an unplanned Impella 5.5 implant. Results: A total of 126 patients were supported with the Impella 5.5. Overall survival to device explant was 76.2%, with 67.5% surviving to discharge. Midterm survival was assessed with a median follow-up time of 318 days and demonstrated an overall survival of 60.3% and a median of 650 days (549-752). Conclusions: Outcomes after using the Impella 5.5 are variable depending on the indication of use. Patient selection may be of utmost importance and requires further experience with this device to determine who will benefit from insertion.

16.
Artigo em Inglês | MEDLINE | ID: mdl-38367698

RESUMO

OBJECTIVES: The HeartMate 3 (Abbott) left ventricular assist device provides substantial improvement in long-term morbidity and mortality in patients with advanced heart failure. The Implantation of the HeartMate 3 in Subjects With Heart Failure Using Surgical Techniques Other Than Full Median Sternotomy study compares thoracotomy-based implantation clinical outcomes with standard median sternotomy. METHODS: We conducted a prospective, multicenter, single-arm study in patients eligible for HeartMate 3 implantation with thoracotomy-based surgical technique (bilateral thoracotomy or partial upper sternotomy with left thoracotomy). The composite primary end point was survival free of disabling stroke (modified Rankin score >3), or reoperation to remove or replace a malfunctioning device, or conversion to median sternotomy at 6-months postimplant (elective transplants were treated as a success). The primary end point (noninferiority, -15% margin) was assessed with >90% power compared with a propensity score-matched cohort (ratio 1:2) derived from the Multi-Center Study of MagLev Technology in Patients Undergoing Mechanical Circulatory Support Therapy With HeartMate 3 continued access protocol. RESULTS: The study enrolled 102 patients between December 2020 and July 2022 in the thoracotomy-based arm at 23 North American centers. Follow-up concluded in December 2022. In the Implantation of the HeartMate 3 in Subjects With Heart Failure Using Surgical Techniques Other Than Full Median Sternotomy study group, noninferiority criteria was met (absolute between-group difference, -1.2%; Farrington Manning lower 1-sided 95% CI, -9.3%; P < .0025) and event-free survival was not different (85.0% vs 86.2%; hazard ratio, 1.01; 95% CI, 0.58-2.10). Length of stay with thoracotomy-based implant was longer (median, 20 vs 17 days; P = .03). No differences were observed for blood product utilization, adverse events (including right heart failure), functional status, and quality of life between cohorts. CONCLUSIONS: Thoracotomy-based implantation of the HeartMate 3 left ventricular assist device is noninferior to implantation via standard full sternotomy. This study supports thoracotomy-based implantation as an additional standard for surgical implantation of the HeartMate 3 left ventricular assist device.

17.
Ann Thorac Surg ; 115(3): 751-757, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-35430222

RESUMO

BACKGROUND: Severe primary graft failure is a life-threatening complication of heart transplantation that may require venoarterial extracorporeal membrane oxygenation (VA-ECMO) support. Surgical practices and management strategies regarding VA-ECMO vary between and within centers. METHODS: We performed a single-center retrospective cohort study on adult patients who received VA-ECMO for primary graft failure between 2013 and 2020. Clinical data were obtained from chart review and national databases. Patients were stratified by transplantation before or after 2017, when our center adopted additional objective criteria for VA-ECMO, adopted partial-flow support, and changed from central cannulation to chimney graft arterial cannulation of brachiocephalic, axillary, or aorta. The primary outcome was survival to device weaning. Secondary outcomes were survival to discharge, survival to 1 year, complications on support, and time to sedation weaning and extubation. RESULTS: From 276 heart transplant recipients, 39 severe primary graft failure patients requiring VA-ECMO were identified. Incidence of graft failure was 13% (n = 18 of 135) pre-2017 and 15% (n = 21 of 141) post-2017. Survival at all time points improved significantly after 2017, with greatest difference in survival to device weaning (61% pre-2017 vs 100% post-2017). After controlling for other factors in multivariable Cox regression modeling, transplantation after 2017 was a predictor of reduced mortality (hazard ratio, 0.209; 95% CI, 0.06-0.71; P = .01). Significant differences were not observed in other secondary outcomes of recovery. CONCLUSIONS: The new VA-ECMO strategy displayed reasonable survival and a remarkable improvement from the prior system.


Assuntos
Oxigenação por Membrana Extracorpórea , Transplante de Coração , Adulto , Humanos , Estudos Retrospectivos , Artérias , Cateterismo
18.
Comput Med Imaging Graph ; 109: 102289, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37633032

RESUMO

Aortic stenosis (AS) is the most prevalent heart valve disease in western countries that poses a significant public health challenge due to the lack of a medical treatment to prevent valve calcification. Given the aging population demographic, the prevalence of AS is projected to rise, resulting in a progressively significant healthcare and economic burden. While surgical aortic valve replacement (SAVR) has been the gold standard approach, the less invasive transcatheter aortic valve replacement (TAVR) is poised to become the dominant method for high- and medium-risk interventions. Computational simulations using patient-specific models, have opened new research avenues for optimizing emerging devices and predicting clinical outcomes. The traditional techniques of generating digital replicas of patients' aortic root, native valve, and calcification are time-consuming and labor-intensive processes requiring specialized tools and expertise in anatomy. Alternatively, deep learning models, such as the U-Net architecture, have emerged as reliable and fully automated methods for medical image segmentation. Two-dimensional U-Nets have been shown to produce comparable or more accurate results than trained clinicians' manual segmentation while significantly reducing computational costs. In this study, we have developed a fully automatic AI tool capable of reconstructing the digital twin geometry and analyzing the calcification distribution on the aortic valve. The developed automatic segmentation package enables the modeling of patient-specific anatomies, which can then be used to simulate virtual interventional procedures, optimize emerging prosthetic devices, and predict clinical outcomes.


Assuntos
Estenose da Valva Aórtica , Aprendizado Profundo , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Humanos , Idoso , Resultado do Tratamento , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/métodos , Implante de Prótese de Valva Cardíaca/métodos , Fatores de Risco
19.
Eur J Cardiothorac Surg ; 64(4)2023 10 04.
Artigo em Inglês | MEDLINE | ID: mdl-37815836

RESUMO

OBJECTIVES: Malignancy is the leading cause of late mortality after orthotopic heart transplantation (OHT), and the burden of post-transplantation cancer is expected to rise in proportion to increased case volume following the 2018 heart allocation score change. In this report, we evaluated factors associated with de novo malignancy after OHT with a focus on skin and solid organ cancers. METHODS: Patients who underwent OHT at our institution between 1999 and 2018 were retrospectively reviewed (n = 488). Terminal outcomes of death and development of skin and/or solid organ malignancy were assessed as competing risks. Fine-Gray subdistribution hazards regression was used to evaluate the association between perioperative patient and donor characteristics and late-term malignancy outcomes. RESULTS: By 1, 5 and 10 years, an estimated 2%, 17% and 27% of patients developed skin malignancy, while 1%, 5% and 12% of patients developed solid organ malignancy. On multivariable Fine-Gray regression, age [1.05 (1.03-1.08); P < 0.001], government payer insurance [1.77 (1.20-2.59); P = 0.006], family history of malignancy [1.66 (1.15-2.38); P = 0.007] and metformin use [1.73 (1.15-2.59); P = 0.008] were associated with increased risk of melanoma and basal or squamous cell carcinoma. Age [1.08 (1.04-1.12); P < 0.001] and family history of malignancy [2.55 (1.43-4.56); P = 0.002] were associated with an increased risk of solid organ cancer, most commonly prostate and lung cancer. CONCLUSIONS: Vigilant cancer and immunosuppression surveillance is warranted in OHT recipients at late-term follow-up. The cumulative incidence of skin and solid organ malignancies increases temporally after transplantation, and key risk factors for the development of post-OHT malignancy warrant identification and routine monitoring.


Assuntos
Carcinoma de Células Escamosas , Transplante de Coração , Neoplasias , Neoplasias Cutâneas , Masculino , Humanos , Estudos Retrospectivos , Neoplasias/etiologia , Neoplasias/complicações , Transplante de Coração/efeitos adversos , Neoplasias Cutâneas/epidemiologia , Neoplasias Cutâneas/etiologia , Terapia de Imunossupressão/efeitos adversos , Carcinoma de Células Escamosas/etiologia , Fatores de Risco , Incidência
20.
Am J Physiol Heart Circ Physiol ; 302(1): H180-7, 2012 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-22037187

RESUMO

Previous studies of transmural left ventricular (LV) strains suggested that the myocardium overlying the papillary muscle displays decreased deformation relative to the anterior LV free wall or significant regional heterogeneity. These comparisons, however, were made using different hearts. We sought to extend these studies by examining three equatorial LV regions in the same heart during the same heartbeat. Therefore, deformation was analyzed from transmural beadsets placed in the equatorial LV myocardium overlying the anterolateral papillary muscle (PAP), as well as adjacent equatorial LV regions located more anteriorly (ANT) and laterally (LAT). We found that the magnitudes of LAT normal longitudinal and radial strains, as well as major principal strains, were less than ANT, while those of PAP were intermediate. Subepicardial and midwall myofiber angles of LAT, PAP, and ANT were not significantly different, but PAP subendocardial myofiber angles were significantly higher (more longitudinal as opposed to circumferential orientation). Subepicardial and midwall myofiber strains of ANT, PAP, and LAT were not significantly different, but PAP subendocardial myofiber strains were less. Transmural gradients in circumferential and radial normal strains, and major principal strains, were observed in each region. The two main findings of this study were as follows: 1) PAP strains are largely consistent with adjacent LV equatorial free wall regions, and 2) there is a gradient of strains across the anterolateral equatorial left ventricle despite similarities in myofiber angles and strains. These findings point to graduated equatorial LV heterogeneity and suggest that regional differences in myofiber coupling may constitute the basis for such heterogeneity.


Assuntos
Contração Miocárdica , Músculos Papilares/fisiologia , Função Ventricular Esquerda , Animais , Fenômenos Biomecânicos , Cateterismo Cardíaco , Acoplamento Excitação-Contração , Fluoroscopia , Ventrículos do Coração/diagnóstico por imagem , Músculos Papilares/diagnóstico por imagem , Ovinos , Estresse Mecânico , Volume Sistólico , Tantálio , Fatores de Tempo , Pressão Ventricular , Gravação em Vídeo
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa