Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Vet Ophthalmol ; 27(1): 95-100, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37952123

RESUMO

OBJECTIVE: To compare intraocular pressure (IOP) measurements in dogs taken with the Reichert® Tono-Vera® Vet rebound tonometer with and without the automatic positioning system. ANIMALS STUDIED: Measurements were taken on 49 eyes from 26 Beagle-derived dogs with variable genetics-four non-glaucomatous and 22 ADAMTS10-mutant dogs affected with different stages of open-angle glaucoma. Seventeen of the 26 dogs were measured 2-4 times on different days with variable intervals since IOP-lowering medications were administered. PROCEDURES: In each dog, tonometry was performed with the Tono-Vera® Vet using three different methods in a randomized order: (Method 1) Average of three readings with an automatic positioning system; (Method 2) one reading with an automatic positioning system; and (Method 3) average of three readings obtained without the automatic positioning system. Statistical analyses included one-way ANOVA, Tukey pairwise comparisons, and Bland-Altman plots (MiniTab®). RESULTS: With each of the three tonometry methods, 116 measurements were taken, resulting in 348 total IOP measurements with a range of 12.8-49.9 mmHg. The means and standard deviations for each method were 25.4 ± 6.9 mmHg (Method 1), 26.0 ± 7.2 mmHg (Method 2), and 26.9 ± 7.7 mmHg (Method 3), with no significant differences (p = .27). Mean IOP variances were also not significantly different between tonometry methods (p = .24 to .78). CONCLUSIONS: Because mean IOPs and their standard deviations were not statistically different between the three tonometry methods, we conclude that Tono-Vera® Vet measurements conducted without the aid of the positioning system still provide reliable results.


Assuntos
Doenças do Cão , Glaucoma de Ângulo Aberto , Cães , Animais , Pressão Intraocular , Glaucoma de Ângulo Aberto/veterinária , Tonometria Ocular/veterinária , Tonometria Ocular/métodos , Olho , Manometria/veterinária , Reprodutibilidade dos Testes , Doenças do Cão/diagnóstico
2.
Vet Ophthalmol ; 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38563215

RESUMO

OBJECTIVE: To assess the accuracy of canine intraocular pressure (IOP) estimates from the eyeTelemed IOPvet indentation tonometer. ANIMALS STUDIED: Part 1 included 54 eyes from 28 Beagle dogs-23 ADAMTS10-mutants with open-angle glaucoma and 5 normals. Part 2 involved five normal canine ex vivo globes. PROCEDURE: Part 1 (in vivo) compared IOPvet estimates in normal and glaucomatous dogs to Reichert Tono-Vera® Vet rebound tonometry. The three IOPvet estimates were green (normal; <20 mmHg, according to the manufacturer), yellow (elevated; 20-30 mmHg), and red (high; >30 mmHg). In Part 2 (ex vivo), the pressure inside freshly enucleated normal canine eyes was progressively increased from 5 to 80 mmHg and compared to IOPvet estimates. Descriptive statistics compared IOPvet estimates to rebound tonometry and direct manometry, with the threshold from normal to glaucoma set at 30 mmHg. RESULTS: In Part 1 (in vivo), normal pressures (≤30 mmHg) were mainly identified correctly as green or yellow-110 of 111 estimates, corresponding to a specificity of 99%. Only 16 of 125 affected estimates were correctly displayed in the >30-mmHg range; the remaining 109 showed ≤30 mmHg, corresponding to a sensitivity of 13%. In Part 2 (ex vivo), all normal pressures were correctly estimated with green, but 64 of 88 manometric IOPs >30 mmHg were falsely estimated as 20-30 mmHg. CONCLUSIONS: The IOPvet is inaccurate in estimating canine IOP with a low sensitivity at identifying dogs with IOP > 30 mmHg. Canine-specific instrument revision is required to correctly identify elevated (yellow = 20-30 mmHg) and high (red >30 mmHg) IOPs.

3.
Cornea ; 2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38478757

RESUMO

PURPOSE: To retrospectively evaluate and describe the relationship between the use of topical corticosteroids and the development of crystalline corneal opacities (steroid keratopathy) in a colony of research Beagles and Beagle-derived dogs. METHODS: Medical records of 73 purpose-bred Beagles and Beagle-derived dogs were reviewed from June 2012 to May 2021. All dogs were treated with topical ophthalmic corticosteroids for at least 21 days. In addition to regular ophthalmic examination, some dogs also had a systemic lipid profile (n = 6) performed to work up further and characterize the crystalline corneal opacities. Globes of 3 dogs were examined histopathologically. RESULTS: Axial stromal crystalline corneal opacities were appreciated in 25 eyes of 14 dogs after a median of 141 days after initiating treatment (35-396 days). Multiple corticosteroids were used, including neomycin-polymyxin b-dexamethasone 0.1% ophthalmic ointment, prednisolone acetate 1% ophthalmic suspension, and difluprednate 0.05% ophthalmic emulsion (Durezol). Resolution of corneal opacity was documented in 4 of 25 eyes when ophthalmic corticosteroids were discontinued after a median of 406.5 days (271-416 days). Histopathologic examination revealed a dense band of acellular material, poorly staining with periodic acid-Schiff, subtending the corneal epithelium, and being surrounded by spindle cells. CONCLUSIONS: This case series documents the onset of steroid keratopathy in Beagles and Beagle-derived dogs after treatment with ophthalmic corticosteroids. Clinical resolution of steroid keratopathy lesions may be possible after discontinuation of ophthalmic corticosteroids.

4.
Front Bioeng Biotechnol ; 11: 1242166, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38130820

RESUMO

Introduction: The role of ocular rigidity and biomechanics remains incompletely understood in glaucoma, including assessing an individual's sensitivity to intraocular pressure (IOP). In this regard, the clinical assessment of ocular biomechanics represents an important need. The purpose of this study was to determine a possible relationship between the G661R missense mutation in the ADAMTS10 gene and the ocular pulse amplitude (OPA), the difference between diastolic and systolic intraocular pressure (IOP), in a well-established canine model of open-angle glaucoma (OAG). Methods: Animals studied included 39 ADAMTS10-mutant dogs with different stages of OAG and 14 unaffected control male and female dogs between 6 months and 12 years (median: 3.2 years). Dogs were sedated intravenously with butorphanol tartrate and midazolam HCl, and their IOPs were measured with the Icare® Tonovet rebound tonometer. The Reichert Model 30™ Pneumotonometer was used to measure OPA. Central corneal thickness (CCT) was measured via Accutome® PachPen, and A-scan biometry was assessed with DGH Technology Scanmate. All outcome measures of left and right eyes were averaged for each dog. Data analysis was conducted with ANOVA, ANCOVA, and regression models. Results: ADAMTS10-OAG-affected dogs displayed a greater IOP of 23.0 ± 7.0 mmHg (mean ± SD) compared to 15.3 ± 3.6 mmHg in normal dogs (p < 0.0001). Mutant dogs had a significantly lower OPA of 4.1 ± 2.0 mmHg compared to 6.5 ± 2.8 mmHg of normal dogs (p < 0.01). There was no significant age effect, but OPA was correlated with IOP in ADAMTS10-mutant dogs. Conclusion: The lower OPA in ADAMTS10-mutant dogs corresponds to the previously documented weaker and biochemically distinct posterior sclera, but a direct relationship remains to be confirmed. The OPA may be a valuable clinical tool to assess ocular stiffness and an individual's susceptibility to IOP elevation.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa