Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 68
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 96(4): 940-946, 2020 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-31797524

RESUMO

OBJECTIVES: We aimed to evaluate early clinical and procedural outcomes with the 34-mm Evolut R transcatheter aortic valve replacement (TAVR) prosthesis. BACKGROUND: The 34-mm Evolut R (Medtronic, Minneapolis, MN) self-expanding TAVR prosthesis was designed to treat patients with larger annuli. METHODS: Clinical, demographic, procedural, and echocardiographic data on consecutive patients who underwent TAVR with a 34-mm Evolut R prosthesis at our institution were collected and analyzed. RESULTS: One hundred ninety-six patients underwent TAVR with this prosthesis from November 2016 to July 2018, a majority (n = 188, 96%) through transfemoral access and with conscious sedation (n = 182, 93%). Mean age, Society of Thoracic Surgery risk score, and follow-up were 82 ± 8 years, 5.4 ± 5%, and 8.2 ± 5.3 months, respectively. Mean aortic valve (AV) peak velocity was 4.0 ± 0.6 m/s, mean AV gradient was 38 ± 13 mmHg, AV area was 0.79 ± 0.23 cm2 ; calcium score was 3,503 ± 1,970 Agatston units, and perimeter was 85 ± 4.3 mm. Device implantation was successful in all but one patient. Postprocedure mean AV peak velocity, AV mean gradient, and AV area were 1.9 ± 0.4 m/s, 7 ± 3 mmHg, and 2.6 ± 0.7 cm2 , respectively. New pacemaker requirement rate was 16%, and moderate paravalvular leak was present in six patients (3%), which improved to mild in three patients at 6-month follow-up. In-hospital, 30-day, 6-month, and 12-month survival rates were 98%, 96% (hospital discharge), 96% (30-day), 89% (6-month), and 83% (12-month). CONCLUSION: These data demonstrate high success and good procedural, echocardiographic, and clinical outcomes of 34-mm Evolut R in patients with large annuli.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Feminino , Mortalidade Hospitalar , Humanos , Masculino , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/terapia , Desenho de Prótese , Recuperação de Função Fisiológica , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
2.
Echocardiography ; 35(12): 1932-1938, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30376591

RESUMO

BACKGROUND: Echocardiography is regarded as the gold standard for diagnosis of bicuspid aortic valve (BAV), yet diagnostic accuracy has been evaluated previously only in single-center studies. We systematically evaluated the accuracy of BAV diagnosis in a large healthcare system of multiple echocardiography laboratories. METHODS AND RESULTS: Aurora Health Care is a multihospital, multi-clinic system across the state of Wisconsin encompassing 33 inpatient and outpatient echocardiography laboratories with 39 cardiologist readers and 72 sonographers. As all laboratories store echocardiograms in one database, we queried all patients with "bicuspid aortic valve" diagnosis on echocardiography. Echocardiograms were classified as "BAV" or "possible BAV" based on initial reader confidence. An expert review panel categorized each as BAV, no BAV, or Indeterminate. Of the 745 cases identified, 589 (79.1%, initial reader interpretation: n = 494 "BAV," n = 95 "possible") were BAV. A high level of agreement (84%) was present in BAV diagnosis. There were 156 (20.9%) echocardiograms that were no BAV (8.4%) or Indeterminate (12.4%). We identified three common reasons for misdiagnosis: poor image quality (n = 70, 44.9%), leaflet calcium (n = 44, 28.2%), and oblique axis imaging (n = 33, 21.1%). A clear reason for misclassification was not elucidated in nine cases (n = 9, 5.7%). CONCLUSIONS: This is the first study to evaluate BAV accuracy across a community health system with multiple echocardiography laboratories and a heterogeneous group of readers and sonographers. We establish a high degree of accuracy of echocardiography in BAV diagnosis and draw attention to common echocardiographic pitfalls that lead to BAV misclassification, highlighting opportunities for education and quality improvement.


Assuntos
Valva Aórtica/anormalidades , Ecocardiografia/métodos , Doenças das Valvas Cardíacas/diagnóstico , Doença da Válvula Aórtica Bicúspide , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos
3.
Comput Inform Nurs ; 36(11): 525-529, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30134257

RESUMO

Clinical decision support systems are used to ensure compliance with guidelines and can assist providers in improving quality of care. This quality improvement initiative was designed to evaluate the use of a clinical decision support system to improve specialist referral rate for patients with severe aortic stenosis. A clinical decision support system for cardiology and primary care providers was implemented to improve diagnosis of severe aortic stenosis. The ordering provider received an electronic medical record in-basket alert providing feedback and recommendations for referral to specialist for evaluation. The echocardiogram data were evaluated for change in specialist referral rate. Before clinical decision support system implementation, the referral rate was 72% for a 3-month period. All providers ordering echocardiograms received clinical decision support system notification if patient results met criteria based on valve severity (aortic valve area < 1.0 cm, mean gradient ≥ 40 mm Hg, peak velocity ≥ 4.0 m/s). After implementation, clinical decision support system referral rate was 97.5%, a 24.6% increase in referral rates (P < .001). Low referral rates for patients with severe aortic stenosis are a recognized challenge. Utilizing the clinical decision support system to improve awareness of quality guidelines and recommendations was associated with increased adherence to referral guidelines by providers. This innovation is pertinent to practice and enhances the functionality of the electronic medical record by providing real-time feedback to providers to improve practice. Referral rates for patients with severe aortic stenosis can be improved with use of provider clinical decision support system.


Assuntos
Estenose da Valva Aórtica/terapia , Sistemas de Apoio a Decisões Clínicas , Melhoria de Qualidade , Encaminhamento e Consulta/estatística & dados numéricos , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Índice de Gravidade de Doença
4.
Curr Cardiol Rep ; 18(7): 62, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-27216842

RESUMO

The role of left ventricular assist devices (LVAD) in patients with end-stage heart failure is well known, both as a temporary treatment before transplantation and as destination therapy, in a scenario of a relative shortage of donors to satisfy the increasing requests for transplantation. The increased population of LVAD patients needs careful imaging assessment before, during, and after LVAD implantation; echocardiography is the best tool for their evaluation and is considered the diagnostic technique of choice for the assessment before, during, and after device implantation. Although the conventional echocardiographic assessment is quite effective in evaluating the main critical issues, the role of new technologies like three-dimensional echocardiography and myocardial deformation measurements is still not properly clarified. In this review, we aim to provide an overview of the main elements that should be considered in the assessment of these patients, underlining the role that could be played by new techniques to improve the diagnostic and prognostic effectiveness of echocardiography in this setting.


Assuntos
Ecocardiografia/tendências , Insuficiência Cardíaca/terapia , Coração Auxiliar , Ecocardiografia/métodos , Ecocardiografia Tridimensional , Falha de Equipamento , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/fisiopatologia , Doenças das Valvas Cardíacas/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Coração Auxiliar/efeitos adversos , Humanos , Assistência Perioperatória/métodos
5.
J Am Soc Echocardiogr ; 37(7): 698-705, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38490315

RESUMO

Interventional echocardiography is a rapidly growing field within the disciplines of cardiology and anesthesiology, with the rise of advanced transcatheter procedures making skilled imagers more important than ever. However, these procedures also involve frequent manipulation of the transesophageal echocardiography probe, which means interventional echocardiographers (IEs) are at risk of long-term occupational radiation exposure. Studies have shown that radiation exposure is linked to various health issues, including cancer, cataracts, hypertension, hyperlipidemia, endothelial dysfunction, vascular aging, and early atherosclerosis. While there is increasing awareness of the occupational radiation dose limits and the need for better shielding methods, the importance of radiation safety for the IE is still not sufficiently prioritized in most cardiac catheterization laboratories/hybrid operating rooms. This is partly due to a paucity of studies looking at long-term radiation exposure to the IE, as this field is newer than that of interventional cardiologists.


Assuntos
Exposição Ocupacional , Exposição à Radiação , Humanos , Exposição Ocupacional/prevenção & controle , Exposição à Radiação/prevenção & controle , Ecocardiografia/métodos , Ultrassonografia de Intervenção/métodos , Proteção Radiológica/métodos , Doses de Radiação
6.
J Am Soc Echocardiogr ; 37(3): 338-351, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38008131

RESUMO

BACKGROUND: Patients with hypertrophic cardiomyopathy (HCM) have been shown to exhibit abnormal diastolic vessel flow; however, flow pattern profiles and their possible association with different grades of diastolic dysfunction have not been studied. Color Doppler two-dimensional echocardiography permits visualization of the septal perforator arteries, and pulsed-wave Doppler allows recording of diastolic septal artery flow (SAF). Through routine visualization of the septal perforator arteries and acquisition of SAF, we noticed 3 patterns of SAF in patients with HCM. In this study, we aimed to assess the feasibility of the acquisition of SAF and to describe types of SAF in an HCM cohort and their associations with diastolic function. METHODS: We reviewed two-dimensional echocardiograms and the electronic records of 108 patients with HCM in whom septal artery color and spectral Doppler had been performed. The peak diastolic and end-diastolic velocities, diastolic slope, diastolic flow time-velocity integral, and systolic flow reversal of the septal perforator arteries were recorded with pulsed-wave Doppler. Echocardiographic and clinical characteristics were analyzed. RESULTS: A reproducible pulsed-wave Doppler tracing was recorded in 54% of patients with HCM. Three distinct patterns of SAF were identified: type 1-smooth, linear holodiastolic velocity decrease; type 2-with presence of an atrial dip; and type 3-biphasic velocity decrease with an early, rapid diastolic slope and a mid-to-late gentle slope. These 3 SAFs correlated with different grades of diastolic dysfunction. CONCLUSION: Septal artery flow could be detected in more than 50% of patients with HCM. Three distinct types of SAF were identified, correlating with different grades of diastolic dysfunction. These 3 types of SAF can provide additional information about left ventricular end-diastolic pressure and diastolic function in patients with HCM in whom diastolic function may be difficult to determine.


Assuntos
Cardiomiopatia Hipertrófica , Humanos , Velocidade do Fluxo Sanguíneo , Cardiomiopatia Hipertrófica/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Diástole , Ecocardiografia
7.
Struct Heart ; 8(3): 100278, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38799807

RESUMO

Background: The current clinical practice standard is 10% to 20% oversizing of self-expanding valves in transcatheter aortic valve replacement. We aimed to determine whether >20% oversizing of self-expanding valves (Medtronic Evolut) would lead to better valve performance with similar or better outcomes. Methods: From October 2011 to December 2016, we approached all transcatheter aortic valve replacement patients with a conscious attempt at large oversizing (>20%). The most common valve used, excluding those used in valve-in-valve patients, was the 29-mm Evolut R (29%). We used a retrospective chart review to compare moderate oversizing (group 1; 10% to 20%) with large oversizing (group 2; >20%). Results: Of 556 patients, 45% were male; the overall mean Society of Thoracic Surgeons risk score was 5.8 ± 3.8. Eighty-five (15%) patients needed a pacemaker, and 21 (3.8%) developed significant paravalvular leak. Mean oversizing was 20.3% ± 6.0%, with 41.4% of patients included in group 1 and 54.5% in group 2. Incidences of complications in group 2 vs. group 1 were as follows: a) paravalvular leak (2.0 vs. 6.1%; odds ratio = 0.31, p = 0.01), b) pacemaker (15 vs. 14%), c) gastrointestinal bleed (n = 4 vs. 0; 1.3 vs. 0.0%; p = 0.03), d) annular dissection (n = 1 vs. 0; 0.3 vs. 0%; p = 0.29), e) mortality (n = 5 vs. 4; 1.6 vs. 1.7%). Incidence of paravalvular leak was higher in those who died than survivors (13 vs. 1.3%; p ≤ 0.0001). Conclusions: These data suggest that, in current self-expanding valves, >20% oversizing delivers a significantly lower prevalence of paravalvular leak without an increase in other complications. Since paravalvular leak is associated with increased mortality, >20% oversizing may represent a superior prosthesis choice.

8.
Circ Cardiovasc Imaging ; 17(2): e015712, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38377241

RESUMO

BACKGROUND: Coronary artery calcium computed tomography (CAC) is an important tool for identifying subclinical atherosclerosis and cardiovascular risk stratification. Despite robust evidence and inclusion in current guidelines, CAC is considered investigational by some US insurance carriers and requires out-of-pocket expenses. CAC can be obtained via self-referral (SR) or physician referral (PR). We aimed to examine differences in patient, socioeconomic, and CAC characteristics between referral groups. METHODS: We evaluated demographic, medical history, and CAC results of consecutive patients with a CAC completed at one of multiple Wisconsin sites from March 1, 2019, to June 30, 2021. We separated patients into SR and PR groups. Through census data, we analyzed socioeconomic variables at the block level including race and ethnicity, median income, average household size, and high school completion in the areas where patients resided at the time of CAC. RESULTS: The final analysis included 19 726 patients: 13 835 (70.1%) PR and 5891 (29.9%) SR. Most patients in both groups were White (95.2% versus 95.1%), with the Black/African American population representing 2.7% (SR) and 2.3% (PR). The PR group had a higher prevalence of cardiovascular risk factors. SR patients were more likely to have a score of 0 (41.2% versus 38.1%; P<0.001); PR patients had a higher prevalence of CAC >300 (16.8% versus 14.8%; P<0.001). SR patients were more likely to be women (55.1% versus 48.9%; P<0.001) and were found to live in higher income areas (19.5% versus 16.4%; P<0.001). Patients from low-income areas comprised the smallest proportion in both groups (7.5%). CONCLUSIONS: Patients who obtain out-of-pocket CAC live predominantly in medium- and high-income areas, and patients from lower income locations are less likely to obtain CAC despite having more cardiovascular disease risk factors. Consideration should be made from a policy perspective to promote health equity and improve utilization of CAC testing among underrepresented groups.


Assuntos
Doença da Artéria Coronariana , Calcificação Vascular , Humanos , Feminino , Masculino , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/epidemiologia , Cálcio , Vasos Coronários/diagnóstico por imagem , Promoção da Saúde , Fatores de Risco , Calcificação Vascular/diagnóstico por imagem , Calcificação Vascular/epidemiologia , Medição de Risco
9.
Plant Cell Environ ; 36(7): 1363-78, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23305100

RESUMO

The study of desiccation tolerance of lichens, and of their chlorobionts in particular, has frequently focused on the antioxidant system that protects the cell against photo-oxidative stress during dehydration/rehydration cycles. In this study, we used proteomic and transcript analyses to assess the changes associated with desiccation in the isolated phycobiont Asterochloris erici. Algae were dried either slowly (5-6 h) or rapidly (<60 min), and rehydrated after 24 h in the desiccated state. To identify proteins that accumulated during the drying or rehydration processes, we employed two-dimensional (2D) difference gel electrophoresis (DIGE) coupled with individual protein identification using trypsin digestion and liquid chromatography-tandem mass spectrometry (LC-MS/MS). Proteomic analyses revealed that desiccation caused an increase in relative abundance of only 11-13 proteins, regardless of drying rate, involved in glycolysis, cellular protection, cytoskeleton, cell cycle, and targeting and degradation. Transcripts of five Hsp90 and two ß-tubulin genes accumulated primarily at the end of the dehydration process. In addition, transmission electron microscopy (TEM) images indicate that ultrastructural cell injuries, perhaps resulting from physical or mechanical stress rather than metabolic damage, were more intense after rapid dehydration. This occurred with no major change in the proteome. These results suggest that desiccation tolerance of A. erici is achieved by constitutive mechanisms.


Assuntos
Clorófitas/fisiologia , Proteômica/métodos , Estresse Fisiológico , Clorófitas/metabolismo , Clorófitas/ultraestrutura , Dessecação , Eletroforese em Gel Bidimensional , Líquens/fisiologia , Proteínas de Plantas/metabolismo , RNA Mensageiro/metabolismo , Espectrometria de Massas em Tandem
10.
Z Naturforsch C J Biosci ; 68(1-2): 3-7, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23659166

RESUMO

Two new furanocoumarins, 5-(1",1"-dimethylallyl)-8-methyl psoralen (1) and 2"-O-acetyl oxypeucedanin hydrate-3"-methyl ether (2), were isolated from the root heartwood of Ficus carica Linn. together with three known furanocoumarins, two triterpenoids, two long-chain compounds, and a steroid. Their structures and relative configurations were elucidated by spectroscopic methods (IR, HR-ESI-MS, and NMR) and by comparison of their NMR spectral data with those of related compounds.


Assuntos
Cumarínicos/isolamento & purificação , Ficus/química , Furanos/química , Raízes de Plantas/química , Cumarínicos/química , Espectroscopia de Ressonância Magnética , Espectrometria de Massas por Ionização por Electrospray , Espectrofotometria Infravermelho
11.
Front Psychol ; 14: 1104973, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36935969

RESUMO

The present study examines the mediating role of emotion-focused and problem-focused coping between stress and psychological well-being during the COVID-19 pandemic. The sample comprised 501 (312 women and 184 men aged between 18 and 42) Indians who experienced the first-ever continued lockdown in India during the COVID-19 pandemic. The results of this study confirmed the presence of perceived stress due to the lockdown and pandemic among participants. Furthermore, perceived stress, coping including emotion-focused and problem-focused, and psychological well-being were found to be interrelated. The serial mediation analysis revealed that participants dealt with stress by choosing emotion-focused coping first as an immediate resort. After a reappraisal of stress-inducing situations, they used problem-focused coping, and this sequence of constant coping mechanisms helped maintain their psychological well-being. The findings of this study can be applied to develop strategies for people's mental health by public health organizations and health professionals.

12.
Circ Cardiovasc Imaging ; 16(2): e014419, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36734221

RESUMO

Myocardial work is an emerging tool in echocardiography that incorporates left ventricular afterload into global longitudinal strain analysis. Myocardial work correlates with myocardial oxygen consumption, and work efficiency can also be assessed. Myocardial work has been evaluated in a variety of clinical conditions to assess the added value of myocardial work compared to left ventricular ejection fraction and global longitudinal strain. This review showcases the current use of myocardial work in adult echocardiography and its possible role in cardiac pathologies.


Assuntos
Estenose da Valva Aórtica , Função Ventricular Esquerda , Adulto , Humanos , Volume Sistólico , Coração , Ecocardiografia
13.
Am J Cardiol ; 208: 37-43, 2023 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-37812864

RESUMO

Optimal timing for aortic valve replacement in symptomatic patients with less than severe aortic stenosis (AS) is not well defined. There is limited information on the benefit of valve replacement in these patients. Symptomatic patients with less than severe AS, defined as a mean aortic gradient ≥20 and <40 mm Hg, peak aortic velocity >3 and <4 m/s, and aortic valve area >1.0 and <1.5 cm2, enrolled in the Society for Thoracic Surgery/American College of Cardiology Transcatheter Valve Therapy Registry and who underwent attempted supra-annular, self-expanding transcatheter aortic valve replacement (TAVR) were reviewed. Site-reported valve hemodynamics, clinical events, and quality of life metrics were analyzed at 30 days and 1 year after the procedure. A total of 1,067 patients with attempted TAVR (mean age 78.4 ± 8.4 years; Society for Thoracic Surgery score 4.7 ± 3.4%) were found to have symptoms but less than severe AS. From baseline to postprocedure, mean gradient decreased (29.9 ± 4.9 vs 8.4 ± 4.8 mm Hg, p <0.001), and aortic valve area increased (1.2 ± 0.1 vs 2.2 ± 0.7 cm2, p <0.001). Clinical events included 30-day and 1-year all-cause mortality (1.5% and 9.6%), stroke (2.2% and 3.3%), and new pacemaker implantation (18.1% and 20.9%). There were statistically significant improvements in the New York Heart Association functional class and Kansas City Cardiomyopathy Questionnaire at 30 days and 1 year. In conclusion, patients with symptomatic but less than severe AS who underwent supra-annular, self-expanding TAVR experienced improved valve hemodynamics and quality of life measures 1 year after the procedure. Randomized studies of TAVR versus a control arm in symptomatic patients with less than severe AS are ongoing.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Idoso , Idoso de 80 Anos ou mais , Substituição da Valva Aórtica Transcateter/efeitos adversos , Qualidade de Vida , Resultado do Tratamento , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Ecocardiografia , Fatores de Risco
14.
J Am Soc Echocardiogr ; 36(10): 1043-1054.e3, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37406714

RESUMO

BACKGROUND: Pressure-strain loop analysis is a novel echocardiographic technique to calculate myocardial work indices that has not been applied to patients with apical hypertrophic cardiomyopathy (ApHCM). We hypothesized that myocardial work indices differ between patients with ApHCM and those with non-ApHCM. This study aimed to (1) evaluate myocardial work indices in patients with ApHCM compared with those with non-ApHCM, (2) describe associations with relevant clinical variables, and (3) examine associations with significant late gadolinium enhancement (LGE) on cardiac magnetic resonance imaging. METHODS: We retrospectively identified 48 patients with ApHCM and 69 with non-ApHCM who had measurements of global longitudinal strain (GLS), global work index (GWI), global constructive work (GCW), global wasted work, and global work efficiency. We evaluated available cardiac magnetic resonance imaging data on 34 patients with ApHCM and 51 with non-ApHCM. Multivariable regression models correcting for traditional cardiac risk factors were used to evaluate the associations of myocardial work indices with relevant clinical variables. RESULTS: Median GLS (-11% vs -18%, P < .001), GWI (966 mm Hg% vs 1803 mm Hg%, P < .001), and GCW (1,050 mm Hg% vs 1,988 mm Hg%, P < .001) were significantly impaired in patients with ApHCM compared with those with non-ApHCM. Increasing N-terminal pro b-type natriuretic peptide, abnormal ultrasensitive troponin, and increasing maximal left ventricular wall thickness were significantly associated with reduced GWI and GCW in patients with ApHCM (P < .05). Global constructive work had only modest accuracy (area under the curve [AUC] = 0.70) to predict LGE in patients with ApHCM. However, in patients with non-ApHCM, GLS was the strongest predictor of LGE (AUC = 0.91), with a -17% cutoff yielding 81% sensitivity and 80% specificity. CONCLUSION: Myocardial work indices are significantly impaired in patients with ApHCM compared to those with non-ApHCM and correlate with important clinical variables. Global longitudinal strain, GWI, and GCW are more strongly predictive of fibrosis in patients with non-ApHCM than ApHCM.

15.
JAMA Cardiol ; 8(2): 111-119, 2023 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-36515976

RESUMO

Importance: The frequency and clinical importance of structural valve deterioration (SVD) in patients undergoing self-expanding transcatheter aortic valve implantation (TAVI) or surgery is poorly understood. Objective: To evaluate the 5-year incidence, clinical outcomes, and predictors of hemodynamic SVD in patients undergoing self-expanding TAVI or surgery. Design, Setting, and Participants: This post hoc analysis pooled data from the CoreValve US High Risk Pivotal (n = 615) and SURTAVI (n = 1484) randomized clinical trials (RCTs); it was supplemented by the CoreValve Extreme Risk Pivotal trial (n = 485) and CoreValve Continued Access Study (n = 2178). Patients with severe aortic valve stenosis deemed to be at intermediate or increased risk of 30-day surgical mortality were included. Data were collected from December 2010 to June 2016, and data were analyzed from December 2021 to October 2022. Interventions: Patients were randomized to self-expanding TAVI or surgery in the RCTs or underwent self-expanding TAVI for clinical indications in the nonrandomized studies. Main Outcomes and Measures: The primary end point was the incidence of SVD through 5 years (from the RCTs). Factors associated with SVD and its association with clinical outcomes were evaluated for the pooled RCT and non-RCT population. SVD was defined as (1) an increase in mean gradient of 10 mm Hg or greater from discharge or at 30 days to last echocardiography with a final mean gradient of 20 mm Hg or greater or (2) new-onset moderate or severe intraprosthetic aortic regurgitation or an increase of 1 grade or more. Results: Of 4762 included patients, 2605 (54.7%) were male, and the mean (SD) age was 82.1 (7.4) years. A total of 2099 RCT patients, including 1128 who received TAVI and 971 who received surgery, and 2663 non-RCT patients who received TAVI were included. The cumulative incidence of SVD treating death as a competing risk was lower in patients undergoing TAVI than surgery (TAVI, 2.20%; surgery, 4.38%; hazard ratio [HR], 0.46; 95% CI, 0.27-0.78; P = .004). This lower risk was most pronounced in patients with smaller annuli (23 mm diameter or smaller; TAVI, 1.32%; surgery, 5.84%; HR, 0.21; 95% CI, 0.06-0.73; P = .02). SVD was associated with increased 5-year all-cause mortality (HR, 2.03; 95% CI, 1.46-2.82; P < .001), cardiovascular mortality (HR, 1.86; 95% CI, 1.20-2.90; P = .006), and valve disease or worsening heart failure hospitalizations (HR, 2.17; 95% CI, 1.23-3.84; P = .008). Predictors of SVD were developed from multivariate analysis. Conclusions and Relevance: This study found a lower rate of SVD in patients undergoing self-expanding TAVI vs surgery at 5 years. Doppler echocardiography was a valuable tool to detect SVD, which was associated with worse clinical outcomes. Trial Registration: ClinicalTrials.gov Identifiers: NCT01240902, NCT01586910, and NCT01531374.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Masculino , Humanos , Idoso de 80 Anos ou mais , Feminino , Valva Aórtica/cirurgia , Resultado do Tratamento , Substituição da Valva Aórtica Transcateter/efeitos adversos
17.
J Proteome Res ; 10(5): 2226-37, 2011 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-21417358

RESUMO

Plastids are highly specialized organelles, responsible for photosynthesis and biosynthesis of various phytochemicals. To better understand plastid diversity and metabolism, a quantitative proteomic study of two plastid forms from Brassica napus (oilseed rape) was performed. Plastids were isolated from leaves (chloroplasts) of two-week-old plants and developing embryos (embryoplasts) three-weeks after flowering, using an approach avoiding protein storage vacuole contamination. Proteins from five different plastid preparations were prefractionated by SDS-PAGE and sectioned into multiple bands, and in-gel proteins were subjected to trypsin digestion. Tryptic peptides from each band were eluted and analyzed by liquid chromatography-tandem mass spectrometry (LC-MS/MS) and spectra were searched against a comprehensive plant database. Proteins were quantified based on MS/MS spectral counting of unique, nonhomologous peptides. Functional classification and quantitative comparison of over 2000 redundant proteins (compiled to 675 nonredundant proteins) determined that light reaction proteins are more prominent in chloroplasts, while many Calvin cycle enzymes are more prominent in embryoplasts. Embryoplasts also contain a diversity of other metabolic enzymes undetected in chloroplasts. Many enzymes involved in de novo fatty acid and amino acid biosynthesis were detected in embryoplasts but not chloroplasts. Additionally, protein synthesis-related proteins were prominent in embryoplasts. Collectively, these results indicate that these two plastid types are distinct.


Assuntos
Brassica napus/embriologia , Brassica napus/genética , Folhas de Planta/metabolismo , Proteínas de Plantas/metabolismo , Plastídeos/metabolismo , Proteômica/métodos , Brassica napus/metabolismo , Cromatografia Líquida , Eletroforese em Gel de Poliacrilamida , Proteínas de Plantas/isolamento & purificação , Espectrometria de Massas em Tandem , Tripsina
19.
J Patient Cent Res Rev ; 8(2): 146-150, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33898648

RESUMO

PURPOSE: Transesophageal echocardiography is an aerosol-generating procedure, and exercise stress testing is a potentially aerosol-generating activity. Concern has been raised about heightened risk of transmission of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) among health care personnel participating in these procedures. We aimed to investigate the prevalence of past coronavirus disease 2019 (COVID-19) infection in echocardiography and stress laboratory staff. METHODS: All staff who worked in the echocardiography and stress laboratories of one high-traffic urban hospital from March 15, 2020, to June 15, 2020, were asked to voluntarily participate. Those willing to participate were consented, and past COVID-19 infection was confirmed by a SARS-CoV-2 IgG antibody test (ARCHITECT, Abbott Laboratories) from June 15, 2020, to July 3, 2020. Clinical data were collected from the electronic medical record, and self-reported symptoms were documented with a participant survey. RESULTS: A total of 43 staff members (86.0% of 50 total laboratory staff) participated. A majority of participants were less than 40 years old (69.8%), were White (86.0%), and were women (79.1%); mean body mass index was 24.9 ± 4.7 kg/m2. Of the 43 staff members tested for past COVID-19 infection, 3 (7.0%) had a positive SARS-CoV-2 IgG antibody result. There were no unique features in the 3 SARS-CoV-2 antibody-positive subjects; of these, 2 had known prior COVID-19 infection and 1 was asymptomatic. CONCLUSIONS: This study provides clinical data on the seroprevalence of SARS-CoV-2 antibody in echocardiography and stress laboratory staff who regularly participate in a variety of procedures that are or may be aerosol-generating.

20.
J Patient Cent Res Rev ; 8(2): 151-153, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33898649

RESUMO

The COVID-19 pandemic led to a nationwide shutdown of elective medical procedures. Upon resumption of services, preprocedure nasopharyngeal swab testing for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) was introduced for all patients requiring surgical or other aerosol-generating procedures. We investigated preprocedure COVID-19 testing in one of the largest U.S. health systems. Patients included in this retrospective, observational study were asymptomatic and scheduled for a procedure or surgery. All patients underwent a nasopharyngeal swab test for SARS-CoV-2 performed 24-72 hours prior to a planned procedure. Clinical demographics, type of procedure, test results, and subsequent procedure status were evaluated. Of 38,608 total patients, there were 277 COVID-19-positive patients (positivity rate: 0.72%). Of those 277, 244 (88%) had procedural delays or cancellations. Of the COVID-19-negative patients, 50 (0.13%) required later hospitalization for COVID-19. Median time from preprocedure negative test to admission was 46.3 ± 27.2 days. In the largest series published on preprocedure COVID-19 testing in the early phase of the pandemic, preprocedure COVID-19 positivity was low. Preprocedure COVID-19 testing had a significant impact on clinical management. Rate of COVID-19 cases requiring hospitalization in the months following the procedure was negligible, suggesting health system policies adequately protected patient safety.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa