Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Surg Endosc ; 34(7): 2947-2953, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-31451918

RESUMO

BACKGROUND: Laparoscopic suturing can be technically challenging and requires extensive training to achieve competency. To date no specific and objective assessment method for laparoscopic suturing and knot tying is available that can guide training and monitor performance in these complex surgical skills. In this study we aimed to develop a laparoscopic suturing competency assessment tool (LS-CAT) and assess its inter-observer reliability. METHODS: We developed a bespoke CAT tool for laparoscopic suturing through a structured, mixed methodology approach, overseen by a steering committee with experience in developing surgical assessment tools. A wide Delphi consultation with over twelve experts in laparoscopic surgery guided the development stages of the tool. Following, subjects with different levels of laparoscopic expertise were included to evaluate this tool, using a simulated laparoscopic suturing task which involved placing of two surgical knots. A research assistant video recorded and anonymised each performance. Two blinded expert surgeons assessed the anonymised videos using the developed LS-CAT. The LS-CAT scores of the two experts were compared to assess the inter-observer reliability. Lastly, we compared the subjects' LS-CAT performance scores at the beginning and end of their learning curve. RESULTS: This study evaluated a novel LS-CAT performance tool, comprising of four tasks. Thirty-six complete videos were analysed and evaluated with the LS-CAT, of which the scores demonstrated excellent inter-observer reliability. Cohen's Kappa analysis revealed good to excellent levels of agreement for almost all tasks of both instrument handling and tissue handling (0.87; 0.77; 0.75; 0.86; 0.85, all with p < 0.001). Subjects performed significantly better at the end of their learning curve compared to their first attempt for all LS-CAT items (all with p < 0.001). CONCLUSIONS: We developed the LS-CAT, which is a laparoscopic suturing grading matrix, with excellent inter-rater reliability and to discriminate between experience levels. This LS-CAT has a potential for wider use to objectively assess laparoscopic suturing skills.


Assuntos
Competência Clínica , Laparoscopia/educação , Técnicas de Sutura/educação , Humanos , Curva de Aprendizado , Reprodutibilidade dos Testes , Cirurgiões/educação , Suturas , Gravação em Vídeo
2.
J Med Syst ; 44(3): 56, 2020 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-31980955

RESUMO

Motion tracking software for assessing laparoscopic surgical proficiency has been proven to be effective in differentiating between expert and novice performances. However, with several indices that can be generated from the software, there is no set threshold that can be used to benchmark performances. The aim of this study was to identify the best possible algorithm that can be used to benchmark expert, intermediate and novice performances for objective evaluation of psychomotor skills. 12 video recordings of various surgeons were collected in a blinded fashion. Data from our previous study of 6 experts and 23 novices was also included in the analysis to determine thresholds for performance. Video recording were analyzed both by the Kinovea 0.8.15 software and a blinded expert observer using the CAT form. Multiple algorithms were tested to accurately identify expert and novice performances. ½ L + [Formula: see text] A + [Formula: see text] J scoring of path length, average movement and jerk index respectively resulted in identifying 23/24 performances. Comparing the algorithm to CAT assessment yielded in a linear regression coefficient R2 of 0.844. The value of motion tracking software in providing objective clinical evaluation and retrospective analysis is evident. Given the prospective use of this tool the algorithm developed in this study proves to be effective in benchmarking performances for psychomotor skills evaluation.


Assuntos
Algoritmos , Colecistectomia Laparoscópica/métodos , Competência Clínica , Movimento/fisiologia , Software , Análise e Desempenho de Tarefas , Humanos , Gravação em Vídeo
3.
Surg Endosc ; 32(6): 2994-2999, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29340824

RESUMO

BACKGROUND: The use of motion tracking has been proved to provide an objective assessment in surgical skills training. Current systems, however, require the use of additional equipment or specialised laparoscopic instruments and cameras to extract the data. The aim of this study was to determine the possibility of using a software-based solution to extract the data. METHODS: 6 expert and 23 novice participants performed a basic laparoscopic cholecystectomy procedure in the operating room. The recorded videos were analysed using Kinovea 0.8.15 and the following parameters calculated the path length, average instrument movement and number of sudden or extreme movements. RESULTS: The analysed data showed that experts had significantly shorter path length (median 127 cm vs. 187 cm, p = 0.01), smaller average movements (median 0.40 cm vs. 0.32 cm, p = 0.002) and fewer sudden movements (median 14.00 vs. 21.61, p = 0.001) than their novice counterparts. CONCLUSION: The use of software-based video motion tracking of laparoscopic cholecystectomy is a simple and viable method enabling objective assessment of surgical performance. It provides clear discrimination between expert and novice performance.


Assuntos
Colecistectomia Laparoscópica/educação , Competência Clínica , Software , Gravação em Vídeo , Humanos
4.
Surg Endosc ; 31(6): 2451-2456, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-27655377

RESUMO

BACKGROUND: The concept of self-assessment has been widely acclaimed for its role in the professional development cycle and self-regulation. In the field of medical education, self-assessment has been most used to evaluate the cognitive knowledge of students. The complexity of training and evaluation in laparoscopic surgery has previously acted as a barrier in determining the benefits self-assessment has to offer in comparison with other fields of medical education. METHODS: Thirty-five surgical residents who attended the 2-day Laparoscopic Surgical Skills Grade 1 Level 1 curriculum were invited to participate from The Netherlands, India and Romania. The competency assessment tool (CAT) for laparoscopic cholecystectomy was used for self- and expert-assessment and the resulting distributions assessed. RESULTS: A comparison between the expert- and self-assessed aggregates of scores from the CAT agreed with previous studies. Uniquely to this study, the aggregates of individual sub-categories-'use of instruments'; 'tissue handling'; and errors 'within the component tasks' and the 'end product' from both self- and expert-assessments-were investigated. There was strong positive correlation (r s > 0.5; p < 0.001) between the expert- and self-assessment in all categories with only the 'tissue handling' having a weaker correlation (r s = 0.3; p = 0.04). The distribution of the mean of the differences between self-assessment and expert-assessment suggested no significant difference between the scores of experts and the residents in all categories except the 'end product' evaluation where the difference was significant (W = 119, p = 0.03). CONCLUSION: Self-assessment using the CAT form gives results that are consistently not different from expert-assessment when assessing one's proficiency in surgical skills. Areas where there was less agreement could be explained by variations in the level of training and understanding of the assessment criteria.


Assuntos
Colecistectomia Laparoscópica/educação , Competência Clínica , Internato e Residência , Autoavaliação (Psicologia) , Feminino , Humanos , Índia , Masculino , Países Baixos , Romênia
5.
Surg Endosc ; 31(6): 2607-2615, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-27734203

RESUMO

BACKGROUND: Laparoscopic surgery for colon cancer is associated with improved recovery and similar cancer outcomes at 3 and 5 years in comparison with open surgery. However, long-term survival rates have rarely been reported. Here, we present survival and recurrence rates of the Dutch patients included in the COlon cancer Laparoscopic or Open Resection (COLOR) trial at 10-year follow-up. METHODS: Between March 1997 and March 2003, patients with non-metastatic colon cancer were recruited by 29 hospitals in eight countries and randomised to either laparoscopic or open surgery. Main inclusion criterion for the COLOR trial was solitary adenocarcinoma of the left or right colon. The primary outcome was disease-free survival at 3 years, and secondary outcomes included overall survival and recurrence. The 10-year follow-up data of all Dutch patients were collected. Analysis was by intention-to-treat. The trial was registered at ClinicalTrials.gov (NCT00387842). RESULTS: In total, 1248 patients were randomised, of which 329 were Dutch. Fifty-eight Dutch patients were excluded and 15 were lost to follow-up, leaving 256 patients for 10-year analysis. Median follow-up was 112 months. Disease-free survival rates were 45.2 % in the laparoscopic group and 43.2 % in the open group (difference 2.0 %; 95 % confidence interval (CI) -10.3 to 14.3; p = 0.96). Overall survival rates were 48.4 and 46.7 %, respectively (difference 1.7 %; 95 % CI -10.6 to 14.0; p = 0.83). Stage-specific analysis revealed similar survival rates for both groups. Sixty-two patients were diagnosed with recurrent disease, accounting for 29.4 % in the laparoscopic group and 28.2 % in the open group (difference 1.2 %; 95 % CI -11.1 to 13.5; p = 0.73). Seven patients had port- or wound-site recurrences (laparoscopic n = 3 vs. open n = 4). CONCLUSIONS: Laparoscopic surgery for non-metastatic colon cancer is associated with similar rates of disease-free survival, overall survival and recurrences as open surgery at 10-year follow-up.


Assuntos
Adenocarcinoma/cirurgia , Neoplasias do Colo/cirurgia , Recidiva Local de Neoplasia/cirurgia , Adenocarcinoma/mortalidade , Idoso , Idoso de 80 Anos ou mais , Neoplasias do Colo/mortalidade , Intervalo Livre de Doença , Etnicidade , Feminino , Humanos , Laparoscopia , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/mortalidade , Países Baixos , Taxa de Sobrevida
6.
Surg Technol Int ; 28: 111-6, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27175810

RESUMO

BACKGROUND: The sleeve gastrectomy is being performed increasingly as a primary procedure for the treatment of morbid obesity. A minimally invasive approach is currently applied to the procedure. The two major steps are dissection and stapling. For dissection, several tools have been developed. The goal of this study was to compare the efficiency and the ergonomics of two ultrasonic devices during the sleeve gastrectomy. MATERIALS AND METHODS: Thirty patients were randomised for the use of a cordless Sonicision™ (Covidien, Mansfield, MA) or a cord-containing HARMONIC ACE®+ (Ethicon Endo-Surgery Inc., Cincinnati, OH) during dissection. Both devices were assessed for objective and subjective measures. RESULTS: There was no significant difference in duration of the procedures. The assembly and installation time of the Sonicision™ were significantly shorter; however, the dismantle time was not. No difference in plume formation or dissection failures was found between the devices. Scrub nurses scored the Sonicision™ significantly clearer and easier in use and more reliable. The surgeons, however, did not find one of the devices easier in use, more reliable or precise, but they did report better manoeuvrability of the Sonicision™. CONCLUSION: In comparison to the wired HARMONIC ACE®+, during sleeve gastrectomy, the cordless Sonicision™ was considered easier to use, faster during assembling and installation, and more reliable with better manoeuvrability. Surgeons scored both devices equally effective. Both ultrasonic devices can be used easily and safely for a sleeve gastrectomy.


Assuntos
Dissecação/instrumentação , Fontes de Energia Elétrica , Gastrectomia/instrumentação , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Procedimentos Cirúrgicos Ultrassônicos/instrumentação , Adulto , Atitude do Pessoal de Saúde , Desenho de Equipamento , Análise de Falha de Equipamento , Ergonomia/instrumentação , Feminino , Humanos , Masculino , Duração da Cirurgia , Resultado do Tratamento
7.
Surg Technol Int ; 27: 123-8, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26680415

RESUMO

The sleeve gastrectomy has been accepted as a primary bariatric procedure. One of the most feared complications is staple line leakage. It is important to use the right staple sizes to minimize the risk of leak. Knowledge of gastric thickness is important. The goal of this study was to measure the thickness of the gastric wall after elimination of the gastric folds in the mucosa. An electronic thickness gauge was developed that measured the anterior and posterior wall of the fresh stomach specimen together at 5 points at a pressure based on the finger pressure necessary to flatten the gastric folds. Thirty-three fresh specimens were measured. The mean compression pressure was 714 grams, and no difference was found between the 5 measure points. There was a significant difference in stomach wall thickness. The gastric antrum was more than 1 mm thicker than the fundus. No difference was found between BMI groups <40 Kg/m2, 40-50 Kg/m2, or >50 Kg/m2. No bleeding occurred, leakage occurred in 1 case. There is a significant difference in thickness of the stomach wall between the gastric fundus and the antrum. A pressure 2.5 times lower than applied in prior studies was necessary to achieve full tissue compression. Choosing thinner staple sizes for the gastric fundus might be the optimal technique for compression. However, there are several additional factors that influence the risk of staple line leaks.


Assuntos
Gastrectomia/instrumentação , Gastrectomia/métodos , Estômago/fisiologia , Adulto , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Estudos Prospectivos
8.
Surg Endosc ; 28(5): 1545-54, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24399519

RESUMO

BACKGROUND: Minimal access surgery and, lately, single-incision laparoscopic procedures are challenging and demanding with regard to the skills of the surgeon performing the procedures. This article presents the results of an investigation of the performance and attention focus of 21 medical interns and surgical residents training in an immersive context. That is, training 'in situation', representing more realistically the demands imposed on the surgeons during minimal access surgery. METHODS: Twenty-one medical interns and surgical residents participated in simulation trainings in an integrated operating room for laparoscopic surgery. Various physiological measures of body heat expenditure were gathered as indicators of mental strain and attention focus. RESULTS: The results of the Mann-Whitney test indicated that participants with a poor performance in the two laparoscopic cholecystectomy cases had a significantly (U = 3, p = 0.038) higher heat flux at the start of the procedure (mean 107.08, standard deviation [SD] 24.34) than those who excelled in the two cases (mean 62.64, SD 23.41). Also, the average frontal head temperature of the participants who failed at the task was significantly lower (mean 33.27, SD 0.52) than those who performed well (mean 33.92, SD 0.27). CONCLUSIONS: Surgeons cannot operate in a bubble; thus, they should not be trained in one. Combining heat flux and frontal head temperature could be a good measure of deep involvement and attentional focus during performance of simulated surgical tasks.


Assuntos
Atenção/fisiologia , Cognição/fisiologia , Educação Médica Continuada/métodos , Temperatura Alta/efeitos adversos , Internato e Residência , Laparoscopia/educação , Salas Cirúrgicas , Adulto , Temperatura Corporal/fisiologia , Competência Clínica , Simulação por Computador , Feminino , Humanos , Laparoscopia/psicologia , Masculino , Carga de Trabalho , Adulto Jovem
9.
Surg Technol Int ; 24: 19-25, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24526423

RESUMO

In recent years, many efforts have been made to reduce the trauma of surgical access further by the use of single-incision laparoscopic surgery (SILS). The Ergo-Lap (ergonomic laparoscopic) simulator was taken to the 20th International Congress of the European Association for Endoscopic Surgery (EAES) in 2012 in Brussels, Belgium. During the congress, the simulator was assessed by 13 general surgeons with different SILS experience using a standardized questionnaire to determine the usability of the Ergo-Lap simulator training for basic SILS skills. Eleven of the 13 participants rated the simulator as an attractive simulator (attractive here means arousing interest of the trainees). For the aspects of training in an ergonomic way, 12 of 13 participants rated it as good to excellent because the work space and task panel location can be adjusted according to the length of instruments. Also, 92% (12 of 13) thought the Ergo-Lap simulator was useful for practicing basic SPLS skills. And 85% (11 of 13) thought it was very easy to use. For SILS skills training, this in~xpensive and portable Ergo-Lap simulator offers a feasible training opportunity to help trainees practice their SILS skills under ergonomic conditions.


Assuntos
Ergonomia/instrumentação , Laparoscopia/educação , Laparoscopia/instrumentação , Cirurgiões/educação , Cirurgiões/estatística & dados numéricos , Adulto , Simulação por Computador , Humanos , Masculino , Pessoa de Meia-Idade
10.
Minim Invasive Ther Allied Technol ; 22(6): 337-45, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23992382

RESUMO

OBJECTIVE: The cost of laparoscopic simulators restricts the wide use of simulation for training of basic psychomotor skills. This paper describes the scientifically-based development of an inexpensive and portable Ergonomic Laparoscopic Skills (Ergo-Lap) simulator with multiple tasks. MATERIAL AND METHODS: The design of this Ergo-Lap simulator and related training task panel was based on scientific research regarding the representative skills and the ergonomic guidelines for laparoscopic surgery. A user-centred design approach was followed. Fifty-three surgical participants with variable laparoscopic experience (14 medical students, 27 surgeons in training, and 12 experienced laparoscopic surgeons) performed several tasks on the prototype and gave their feedback by filling out a 5-point scale Likert scale questionnaire. RESULTS: The results of the usability evaluation showed that the participants regarded the Ergo-Lap simulator as a useful device to practice the basic and advanced skills effectively. Forty-three of the 53 participants indicated they would like to purchase this simulator since it is easy to use and challenges their laparoscopic skills. CONCLUSIONS: For laparoscopic skills training, this inexpensive Ergo-Lap simulator with diverse task choices offers a simple training opportunity for trainees who want to practice laparoscopic skills at home or at the office.


Assuntos
Competência Clínica , Simulação por Computador , Ergonomia/métodos , Laparoscopia/educação , Simulação por Computador/economia , Educação Médica Continuada/economia , Educação Médica Continuada/métodos , Desenho de Equipamento , Ergonomia/economia , Humanos , Guias de Prática Clínica como Assunto , Desempenho Psicomotor , Estudantes de Medicina , Inquéritos e Questionários , Interface Usuário-Computador
11.
Surg Endosc ; 26(8): 2172-8, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22350237

RESUMO

INTRODUCTION: Even though literature provides compelling evidence of the value of simulators for training of basic laparoscopic skills, the best way to incorporate them into a surgical curriculum is unclear. This study compares the training outcome of single modality training with multimodality training of basic laparoscopic skills. METHODS: Thirty-six medical students without laparoscopic experience performed six training sessions of 45 min each, one per day, in which four different basic tasks were trained. Participants in the single-modality group (S) (n = 18) practiced solely on a virtual reality (VR) simulator. Participants in the multimodality group (M) (n = 18) practiced on the same VR simulator (2x), a box trainer (2x), and an augmented reality simulator (2x). All participants performed a pre-test and post-test on the VR simulator (the four basic tasks + one additional basic task). Halfway through the training protocol, both groups performed a salpingectomy on the VR simulator as interim test. RESULTS: Both groups improved their performance significantly (Wilcoxon signed-rank, P < 0.05). The performances of group S and group M in the additional basic task and the salpingectomy did not differ significantly (Mann-Whitney U test, P > 0.05). Group S performed the four basic tasks in the post-test on the VR faster than group M (P ≤ 0.05), which can be explained by the fact that they were much more familiar with these tasks. CONCLUSIONS: Training of basic laparoscopic tasks on single or multiple modalities does not result in different training outcome. Both training methods seem appropriate for the attainment of basic laparoscopic skills in future curricula.


Assuntos
Competência Clínica/normas , Simulação por Computador , Cirurgia Geral/educação , Internato e Residência , Laparoscopia/educação , Interface Usuário-Computador , Humanos , Desempenho Psicomotor , Fatores de Tempo
12.
Surg Endosc ; 26(4): 1095-101, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22042592

RESUMO

INTRODUCTION: The benefits of criterion-based laparoscopic training over time-oriented training are unclear. The purpose of this study is to compare these types of training based on training outcome and time efficiency. METHODS: During four training sessions within 1 week (one session per day) 34 medical interns (no laparoscopic experience) practiced on two basic tasks on the Simbionix LAP Mentor virtual-reality (VR) simulator: 'clipping and grasping' and 'cutting'. Group C (criterion-based) (N = 17) trained to reach predefined criteria and stopped training in each session when these criteria were met, with a maximum training time of 1 h. Group T (time-based) (N = 17) trained for a fixed time of 1 h each session. Retention of skills was assessed 1 week after training. In addition, transferability of skills was established using the Haptica ProMIS augmented-reality simulator. RESULTS: Both groups improved their performance significantly over the course of the training sessions (Wilcoxon signed ranks, P < 0.05). Both groups showed skill transferability and skill retention. When comparing the performance parameters of group C and group T, their performances in the first, the last and the retention training sessions did not differ significantly (Mann-Whitney U test, P > 0.05). The average number of repetitions needed to meet the criteria also did not differ between the groups. Overall, group C spent less time training on the simulator than did group T (74:48 and 120:10 min, respectively; P < 0.001). Group C performed significantly fewer repetitions of each task, overall and in session 2, 3 and 4. CONCLUSIONS: Criterion-based training of basic laparoscopic skills can reduce the overall training time with no impact on training outcome, transferability or retention of skills. Criterion-based should be the training of choice in laparoscopic skills curricula.


Assuntos
Competência Clínica/normas , Internato e Residência/métodos , Laparoscopia/educação , Simulação por Computador , Dissecação/educação , Dissecação/normas , Humanos , Laparoscopia/normas , Materiais de Ensino , Fatores de Tempo
13.
Surg Endosc ; 24(4): 902-7, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19789922

RESUMO

BACKGROUND: Surgeons perform complex tasks while exposed to multiple distracting sources that may increase stress in the operating room (e.g., music, conversation, and unadapted use of sophisticated technologies). This study aimed to examine whether such realistic social and technological distracting conditions may influence surgical performance. METHODS: Twelve medical interns performed a laparoscopic cholecystectomy task with the Xitact LC 3.0 virtual reality simulator under distracting conditions (exposure to music, conversation, and nonoptimal handling of the laparoscope) versus nondistracting conditions (control condition) as part of a 2 x 2 within-subject experimental design. RESULTS: Under distracting conditions, the medical interns showed a significant decline in task performance (overall task score, task errors, and operating time) and significantly increased levels of irritation toward both the assistant handling the laparoscope in a nonoptimal way and the sources of social distraction. Furthermore, individual differences in cognitive style (i.e., cognitive absorption and need for cognition) significantly influenced the levels of irritation experienced by the medical interns. CONCLUSION: The results suggest careful evaluation of the social and technological sources of distraction in the operation room to reduce irritation for the surgeon and provision of proper preclinical laparoscope navigation training to increase security for the patient.


Assuntos
Atenção/fisiologia , Colecistectomia Laparoscópica/educação , Competência Clínica , Processos Mentais/fisiologia , Análise e Desempenho de Tarefas , Simulação por Computador , Humanos , Internato e Residência , Estatísticas não Paramétricas , Interface Usuário-Computador
14.
Surg Endosc ; 24(12): 3134-40, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20526629

RESUMO

BACKGROUND: To bridge the early learning curve for laparoscopic Nissen fundoplication from the clinical setting to a safe environment, training models can be used. This study aimed to develop a reusable, low-cost model to be used for training in laparoscopic Nissen fundoplication procedure as an alternative to the use of animal tissue models. METHODS: From artificial organs and tissue, an anatomic model of the human upper abdomen was developed for training in performing laparoscopic Nissen fundoplication. The 20 participants and tutors in the European Association for Endoscopic Surgery (EAES) upper gastrointestinal surgery course completed four complementary tasks of laparoscopic Nissen fundoplication with the artificial model, then compared the realism, haptic feedback, and training properties of the model with those of animal tissue models. RESULTS: The main difference between the two training models was seen in the properties of the stomach. The wrapping of the stomach in the artificial model was rated significantly lower than that in the animal tissue model (mean, 3.6 vs. 4.2; p = 0.010). The main criticism of the stomach of the artificial model was that it was too rigid for making a proper wrap. The suturing of the stomach wall, however, was regarded as fairly realistic (mean, 3.6). The crura on the artificial model were rated better (mean, 4.3) than those on the animal tissue (mean, 4.0), although the difference was not significant. The participants regarded the model as a good to excellent (mean, 4.3) training tool. CONCLUSION: The newly developed model is regarded as a good tool for training in laparoscopic Nissen fundoplication procedure. It is cheaper, more durable, and more readily available for training and can therefore be used in every training center. The stomach of this model, however, still needs improvement because it is too rigid for making the wrap.


Assuntos
Fundoplicatura/educação , Fundoplicatura/métodos , Laparoscopia/educação , Órgãos Artificiais
15.
Surg Endosc ; 24(8): 1990-5, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20135171

RESUMO

BACKGROUND: Awareness of the relative high rate of adverse events in laparoscopic surgery created a need to safeguard quality and safety of performance better. Technological innovations, such as integrated operating room (OR) systems and checklists, have the potential to improve patient safety, OR efficiency, and surgical outcomes. This study was designed to investigate the influence of the integrated OR system and Pro/cheQ, a digital checklist tool, on the number and type of equipment- and instrument-related risk-sensitive events (RSE) during laparoscopic cholecystectomies. METHODS: Forty-five laparoscopic cholecystectomies were analyzed on the number and type of RSE; 15 procedures were observed in the cart-based OR setting, 15 in an integrated OR setting, and 15 in the integrated OR setting while using Pro/cheQ. RESULTS: In the cart-based OR setting and the integrated OR setting, at least one event occurred in 87% of the procedures, which was reduced to 47% in the integrated OR setting when using Pro/cheQ. During 45 procedures a total of 57 RSE was observed-most were caused by equipment that was not switched on or with the wrong settings. In the integrated OR while using Pro/cheQ the number of RSE was reduced by 65%. CONCLUSIONS: Using both an integrated OR and Pro/cheQ has a stronger reducing effect on the number of RSE than using an integrated OR alone. The Pro/cheQ tool supported the optimal workflow in a natural way and raised the general safety awareness amongst all members of the surgical team. For tools such as integrated OR systems and checklists to succeed it is pivotal not to underestimate the value of the implementation process. To further improve safety and quality of surgery, a multifaceted approach should be followed, focusing on the performance and competence of the surgical team as a whole.


Assuntos
Lista de Checagem , Colecistectomia Laparoscópica , Salas Cirúrgicas/normas , Gestão da Segurança , Colecistectomia Laparoscópica/efeitos adversos , Humanos , Complicações Intraoperatórias/prevenção & controle , Cuidados Pré-Operatórios , Fatores de Risco
16.
Surg Endosc ; 24(12): 2993-3001, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20419318

RESUMO

BACKGROUND: The aim of this study is to investigate the influence of the presence of anatomic landmarks on the performance of angled laparoscope navigation on the SimSurgery SEP simulator. METHODS: Twenty-eight experienced laparoscopic surgeons (familiar with 30° angled laparoscope, >100 basic laparoscopic procedures, >5 advanced laparoscopic procedures) and 23 novices (no laparoscopy experience) performed the Camera Navigation task in an abstract virtual environment (CN-box) and in a virtual representation of the lower abdomen (CN-abdomen). They also rated the realism and added value of the virtual environments on seven-point scales. RESULTS: Within both groups, the CN-box task was accomplished in less time and with shorter tip trajectory than the CN-abdomen task (Wilcoxon test, p < 0.05). No significant differences were found between the performances of the experienced participants and the novices on the CN tasks (Mann-Whitney U test, p > 0.05). In both groups, the CN tasks were perceived as hard work and more challenging than anticipated. CONCLUSIONS: Performance of the angled laparoscope navigation task is influenced by the virtual environment surrounding the exercise. The task was performed better in an abstract environment than in a virtual environment with anatomic landmarks. More insight is required into the influence and function of different types of intrinsic and extrinsic feedback on the effectiveness of preclinical simulator training.


Assuntos
Simulação por Computador , Laparoscopia/educação , Laparoscopia/métodos , Cavidade Abdominal/anatomia & histologia , Adulto , Idoso , Humanos , Pessoa de Meia-Idade , Inquéritos e Questionários , Adulto Jovem
17.
World J Surg ; 34(5): 933-40, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20151134

RESUMO

BACKGROUND: Surgical techniques that draw from multiple types of image-based procedures (IBP) are increasing, such as Natural Orifice Transluminal Endoscopic Surgery, fusing laparoscopy and flexible endoscopy. However, little is known about the relation between psychomotor skills for performing different types of IBP. For example, do basic psychomotor colonoscopy and laparoscopy skills interact? METHODS: Following a cross-over study design, 29 naïve endoscopists were trained on the Simbionix GI Mentor and the SimSurgery SEP simulators. Group C (n = 15) commenced with a laparoscopy session, followed by four colonoscopy sessions and a second laparoscopy session. Group L (n = 14) started with a colonoscopy session, followed by four laparoscopy sessions and a second colonoscopy session. RESULTS: No significant differences were found between the performances of group L and group C in their first training sessions on either technique. With additional colonoscopy training, group C outperformed group L in the second laparoscopy training session on the camera navigation task. CONCLUSIONS: Overall, training in the basic colonoscopy tasks does not affect performance of basic laparoscopy tasks (and vice versa). However, to limited extent, training of basic psychomotor skills for colonoscopy do appear to contribute to the performance of angled laparoscope navigation tasks. Thus, training and assessment of IBP type-specific skills should focus on each type of tasks independently. Future research should further investigate the influence of psychometric abilities on the performance of IBP and the transfer of skills for physicians who are experienced in one IBP type and would like to become proficient in another type of IBP.


Assuntos
Endoscopia , Laparoscopia , Procedimentos Cirúrgicos Minimamente Invasivos/educação , Desempenho Psicomotor , Colonoscopia , Estudos Cross-Over , Educação , Avaliação Educacional , Endoscopia/educação , Humanos , Destreza Motora
18.
Artigo em Inglês | MEDLINE | ID: mdl-20095896

RESUMO

The aim of this study was to assess the performance curve for novices training in bimanual tissue manipulation and angled laparoscope navigation, and compare those performances with the performances of experienced laparoscopic surgeons. The Camera Navigation task with a 30 degrees angled laparoscope and the Place Arrow task of the new SimSurgery SEP virtual reality simulator were used. Fourteen medical trainees (no laparoscopy experience) performed four training sessions within one week, including 15 repetitions of each task in total. The experienced participants (>50 procedures & familiar with angled laparoscope) performed each task twice. The performance on both tasks by the novices improved significantly over the training sessions. The experienced participants performed both tasks significantly better than the novices in repetition 3. After repetition 15, the performances of the novices on both tasks were of the same level as the performances of the experienced participants. By training on SimSurgery SEP, medical trainees can extensively improve their skills in navigation with 30 degrees angled laparoscope and bimanual tissue manipulation. Further research should focus on the transfer of skills acquired on the simulator to the clinical setting. Knowledge on proficiency thresholds and training end-points for pre-clinical criterion-based training of different laparoscopic tasks also needs to be extended.


Assuntos
Competência Clínica , Simulação por Computador , Laparoscopia/normas , Avaliação Educacional , Humanos , Laparoscópios , Laparoscopia/métodos , Interface Usuário-Computador
19.
Surg Endosc ; 23(8): 1693-700, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18813987

RESUMO

BACKGROUND: To prevent unnecessary errors and adverse results of laparoscopic surgery, proper training is of paramount importance. A safe way to train surgeons for laparoscopic skills is simulation. For this purpose traditional box trainers are often used, however they lack objective assessment of performance. Virtual reality laparoscopic simulators assess performance, but lack realistic haptic feedback. Augmented reality (AR) combines a virtual reality (VR) setting with real physical materials, instruments, and feedback. This article presents the current developments in augmented reality laparoscopic simulation. METHODS: Pubmed searches were performed to identify articles regarding surgical simulation and augmented reality. Identified companies manufacturing an AR laparoscopic simulator received the same questionnaire referring to the features of the simulator. RESULTS: Seven simulators that fitted the definition of augmented reality were identified during the literature search. Five of the approached manufacturers returned a completed questionnaire, of which one simulator appeared to be VR and was therefore not applicable for this review. CONCLUSION: Several augmented reality simulators have been developed over the past few years and they are improving rapidly. We recommend the development of AR laparoscopic simulators for component tasks of procedural training. AR simulators should be implemented in current laparoscopic training curricula, in particular for laparoscopic suturing training.


Assuntos
Simulação por Computador , Instrução por Computador/instrumentação , Cirurgia Geral/educação , Laparoscopia , Modelos Anatômicos , Interface Usuário-Computador , Instrução por Computador/métodos , Avaliação Educacional , Retroalimentação Psicológica , Humanos , Conhecimento Psicológico de Resultados , Materiais de Ensino , Tato
20.
Surg Endosc ; 23(4): 750-7, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18626705

RESUMO

BACKGROUND: It is a tacit assumption that clinically based expertise in laparoscopic tissue manipulation entails skilfulness in angled laparoscope navigation. The main objective of this study was to investigate the relation between these skills. To this end, face and construct validity had to be established for the place arrow (PA) and camera navigation (CN) tasks on the SimSurgery SEP. METHODS: Thirty-three novices (no laparoscopy experience) and 33 experienced participants (>50 laparoscopic procedures and familiar with angled laparoscopy) performed both tasks twice, on one of two hardware platforms (SimSurgery SimPack or Xitact/Mentice IHP), and rated the realism and didactic value of SimSurgery SEP on five-point scales. RESULTS: Both tasks were rated by the experienced participants as realistic (CN: 3.7; PA: 4.1) and SimSurgery SEP as a user-friendly environment to train basic skills (4.1). Both tasks were performed in less time by the experienced group, with shorter tip trajectories. For both groups jointly, the time to accomplish each task correlated with the tip trajectory and also with the time and tip trajectories of the opposite task (Spearman's correlation, p

Assuntos
Competência Clínica , Simulação por Computador , Laparoscopia/métodos , Interface Usuário-Computador , Humanos , Inquéritos e Questionários
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa