Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Ultraschall Med ; 37(4): 393-8, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25815457

RESUMO

PURPOSE: To evaluate the feasibility and effectiveness of US-guided sacroiliac joint injection in the treatment of sacroiliitis in children. MATERIALS AND METHODS: This study was approved by the institutional review board and informed oral and written consent was obtained from the patients and their parents. In 13 patients (7 females and 6 males), 9 - 16 years (mean +/- std 11.39 +/-1.98), 18 sacroiliac joint (SI joint) injections were performed under US guidance. All patients suffered from severe sacroiliitis. US scanning was performed using a linear-array transducer operating at 5 - 18 MHz. Rating of the patients pain using a 0 - 10 dolorimetry scale on a visual analog score (VAS) was recorded before, immediately after and 3 months after injection to monitor severity and therapeutic response. RESULTS: Injection could be performed in all patients without complication and showed good response immediately and 3 months after the injection with a decrease of the VAS (from mean +/- std 9.44 +/- 1.097 to 3.89 +/- 3.82, p < 0.001 and to 0.56 +/- 1.097, p < 0.05, respectively). CONCLUSION: US-guided SI joint injection was feasible in all children, relatively quick and easy to perform and appeared effective in the treatment of children with sacroiliitis.


Assuntos
Injeções Intra-Articulares/métodos , Articulação Sacroilíaca/efeitos dos fármacos , Sacroileíte/diagnóstico por imagem , Sacroileíte/tratamento farmacológico , Ultrassonografia de Intervenção , Adolescente , Criança , Estudos de Viabilidade , Feminino , Humanos , Masculino
2.
Plast Reconstr Surg ; 104(6): 1656-65, 1999 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-10541165

RESUMO

The aim of this interdisciplinary study was to evaluate power Doppler imaging as a method of collecting reliable preoperative data concerning the diameters and topography of exemplary internal mammary vessels as recipient vessels in reconstructive microsurgery. Thirteen female patients (range, 37 to 58 years; mean, 45.6 years) were examined preoperatively with power Doppler imaging from the first to the fifth intercostal space parasternally and bilaterally. These data are compared with measurements obtained intraoperatively in each individual. Mean velocity in the artery in the second intercostal space on the right side is 47.11 cm/sec (range, 15 to 90 cm/sec) and on the left side is 42.25 cm/sec (range, 18 to 95 cm/sec). Mean velocity in the vein in the second intercostal space on the right side is 17.80 cm/sec (range, 10 to 30 cm/sec) and on the left side is 13.06 cm/sec (range, 5.3 to 32 cm/sec). The topographic results are in close agreement with intraoperative measurements and previous anatomical studies. Sonographic preoperative data of arteries (mean, 1.88 mm) show slightly smaller diameters than intraoperative measurements (mean, 2.08 mm), whereas veins show slightly larger diameters in sonography (mean, 2.33 mm) than intraoperatively (mean, 2.12 mm). Mean sonographic diameter of artery ranges from 2.14 mm (second intercostal space) to 1.46 mm (fifth intercostal space), of the vein from 2.76 (second intercostal space) to 1.25 mm (fifth intercostal space). In one case, a vein was not detectable. This noninvasive method leads to confirmation of the preoperative choice of the optimal recipient vessels for free tissue transfer and does not harm the patient.


Assuntos
Mamoplastia/métodos , Artéria Torácica Interna/cirurgia , Microcirurgia/métodos , Retalhos Cirúrgicos/irrigação sanguínea , Ultrassonografia Doppler , Adulto , Feminino , Humanos , Artéria Torácica Interna/diagnóstico por imagem , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Veias/diagnóstico por imagem , Veias/cirurgia
4.
Radiologe ; 43(12): 1069-74, 2003 Dec.
Artigo em Alemão | MEDLINE | ID: mdl-14668995

RESUMO

High-resolution computed tomography (HRCT) of the lung is a very valuable method in the evaluation of children with acute and chronic lung disease due to the high spatial resolution and precise display of anatomy and pathology without superposition. The following publication will describe an optimized HRCT technique in order to reduce dose, explain various HRCT pattern and explain typical pediatric lung diseases.


Assuntos
Pneumopatias/diagnóstico por imagem , Tomografia Computadorizada Espiral , Adolescente , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Recém-Nascido , Pneumopatias/congênito , Masculino , Doses de Radiação , Sensibilidade e Especificidade , Avaliação da Tecnologia Biomédica
5.
J Comput Assist Tomogr ; 11(5): 779-84, 1987.
Artigo em Inglês | MEDLINE | ID: mdl-3308987

RESUMO

A modified indicator-dilution technique using radiographic contrast material and a cine-CT scanner was used to measure blood flow in the renal cortex of dogs. To validate this technique, CT measurements were correlated with simultaneous measurements of flow determined by radioactive microspheres. Measurements were taken during euvolemic conditions and after hemorrhage. Thirty-nine measurements were compared, covering a flow range from 1 to 7 ml min-1 g-1, and a good correlation was found between the cine-CT and microsphere results (r = 0.93; p less than 0.001). Additionally, cine-CT measurements were made of the mean transit time (MTT) of contrast material through the renal cortex, and the reciprocal of these MTT values was also well correlated to microsphere determined flow (r = 0.94; p less than 0.001). Thus, cine-CT appears to be a promising new technique for measuring renal blood flow.


Assuntos
Cinerradiografia/métodos , Hemorragia/diagnóstico por imagem , Córtex Renal/diagnóstico por imagem , Circulação Renal , Tomografia Computadorizada por Raios X/métodos , Animais , Velocidade do Fluxo Sanguíneo , Diatrizoato de Meglumina , Cães , Hemorragia/fisiopatologia , Iotalamato de Meglumina , Córtex Renal/irrigação sanguínea , Nefropatias/diagnóstico por imagem , Nefropatias/fisiopatologia , Matemática , Microesferas , Técnica de Diluição de Radioisótopos
6.
Radiology ; 217(2): 544-50, 2000 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-11058658

RESUMO

PURPOSE: To evaluate the feasibility and safety of endovascular stent-graft placement in treating Stanford type B aortic dissection. MATERIALS AND METHODS: Seven patients underwent endovascular stent-graft placement for type B aortic dissection. Five patients had acute and two had chronic dissection. In five patients, the proximal entry tear was within 2 cm of the origin of the left subclavian artery, and in two patients it was beyond this site. In three patients, the noncovered proximal portion of the stent-graft was placed across the origin of the left subclavian artery. The efficacy of the procedure was assessed at follow-up studies 3, 6, 12, and 24 months after intervention. RESULTS: The procedure was technically and clinically successful in six patients (86%). The left subclavian artery remained patent in all patients. In two patients with involvement of aortic branches, endovascular stent-graft placement restored adequate blood flow to the compromised branches. One patient was readmitted 1 month later because the dissection extended into the ascending aorta. In all but this patient, closure of the entry tear and thrombosis of the false lumen along the stent-graft were achieved. All false lumina shrank considerably. The mean follow-up time was 14 months (range, 1-25 months). CONCLUSION: Type B aortic dissections within and beyond 2 cm of the origin of the left subclavian artery can be treated safely and effectively by means of endovascular stent-graft placement.


Assuntos
Aneurisma da Aorta Torácica/terapia , Dissecção Aórtica/terapia , Stents , Adulto , Idoso , Idoso de 80 Anos ou mais , Dissecção Aórtica/diagnóstico por imagem , Aneurisma da Aorta Torácica/diagnóstico por imagem , Prótese Vascular , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia Intervencionista , Tomografia Computadorizada por Raios X
7.
J Endovasc Ther ; 8(4): 380-9, 2001 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-11552730

RESUMO

PURPOSE: To evaluate the efficacy of transluminal stent-graft placement in aortic aneurysms using postoperative enhanced spiral computed tomographic (CT) volumetric measurements of the aneurysm sac, the intra-aneurysmal vascular channel (IAVC), the thrombus, and the stent-graft. METHODS: Among 53 patients (45 men; mean age 74 years, range 59-85) who underwent elective endovascular aortic aneurysm repair, 37 patients with 27 abdominal and 10 thoracic aortic aneurysms completed at least a 6-month follow-up that included computerized CT volumetric analysis prior to discharge and at 3, 6, 12, 24, and 36 months. A variety of bifurcated (n = 23) and tube (n = 14) stent-grafts were observed for signs of endoleak and aneurysm enlargement. RESULTS: Mean follow-up was 16 months (range 6-48). Total aneurysm volumes and thrombus volumes decreased, whereas IAVC and stent-graft volumes increased over time. Between the postoperative and 12-month imaging studies, reductions in total aneurysm (p 0.011) and thrombus (p < 0.001) volumes were significant. No statistically significant difference in volume changes for the aneurysm sac (p = 0.555) or the thrombus (p = 0.920) was found when comparing the 24 patients without primary leak to the 12 with primary type-II leak. In all 5 cases with secondary leak, the volume of the aneurysm sac increased after initial shrinkage. CONCLUSIONS: Postoperative CT volumetric analysis is an effective tool for evaluating the outcome of endovascular aortic aneurysm repair. Thrombus volume measurements are more accurate than total aneurysm volumes. In patients in whom contrast agents are contraindicated, volume measurements can also be obtained without the use of contrast.


Assuntos
Angioplastia , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Tomografia Computadorizada por Raios X , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/complicações , Aneurisma da Aorta Abdominal/diagnóstico , Aneurisma da Aorta Torácica/complicações , Aneurisma da Aorta Torácica/diagnóstico , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Trombose/diagnóstico , Trombose/etiologia , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa