Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Cardiovasc Electrophysiol ; 34(6): 1431-1440, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36786511

RESUMO

INTRODUCTION: It is not known whether the optimal atrioventricular (AVopt ) delay varies between left ventricular (LV) pacing site during endocardial biventricular pacing (BiVP) and may therefore needs consideration. METHODS: We assessed the hemodynamic AVopt in patients with chronic heart failure undergoing endocardial LV lead implantation. AVopt was assessed during atrio-BiVP with a "roving LV lead." Up to four locations were studied: mid-lateral wall, mid-septum (or a close alternative), site of greatest hemodynamic improvement, and LV lead implant site. The AVopt was compared to a fixed AV delay of 180 ms. RESULTS: Seventeen patients were included (12 male, aged 66.5 ± 12.8 years, ejection fraction 26 ± 7%, 16 left bundle branch block or high percentage of right ventricular pacing [RVP], QRS duration 167 ± 27 ms). In most locations (62/63), AVopt increased systolic blood pressure during BiVP compared with RVP (relative improvement 6 mmHg, interquartile range [IQR] 4-9 mmHg). Compared to a fixed AV delay, the hemodynamic improvement at AVopt was higher (1 mmHg, IQR 0.2-2.6 mmHg, p < .001). Within most patients (16/17), we observed a difference in AVopt between pacing sites (median paced AVopt 209 ms, IQR 117-250). Within this range, the hemodynamic impact of these differences was small (median loss 0.6 mmHg, IQR 0.1-2.6 mmHg). CONCLUSION: Within a patient, different endocardial LV lead locations have slightly different hemodynamic AVopt which are superior to a fixed AV delay. The hemodynamic consequence of applying an optimum from a different lead location is small.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Masculino , Terapia de Ressincronização Cardíaca/efeitos adversos , Hemodinâmica/fisiologia , Bloqueio de Ramo , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Ventrículos do Coração , Função Ventricular Esquerda/fisiologia , Estimulação Cardíaca Artificial
2.
Neural Plast ; 2019: 2564018, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31565045

RESUMO

Monocular deprivation (MD) during the critical period (CP) has enduring effects on visual acuity and the functioning of the visual cortex (V1). This experience-dependent plasticity has become a model for studying the mechanisms, especially glutamatergic and GABAergic receptors, that regulate amblyopia. Less is known, however, about treatment-induced changes to those receptors and if those changes differentiate treatments that support the recovery of acuity versus persistent acuity deficits. Here, we use an animal model to explore the effects of 3 visual treatments started during the CP (n = 24, 10 male and 14 female): binocular vision (BV) that promotes good acuity versus reverse occlusion (RO) and binocular deprivation (BD) that causes persistent acuity deficits. We measured the recovery of a collection of glutamatergic and GABAergic receptor subunits in the V1 and modeled recovery of kinetics for NMDAR and GABAAR. There was a complex pattern of protein changes that prompted us to develop an unbiased data-driven approach for these high-dimensional data analyses to identify plasticity features and construct plasticity phenotypes. Cluster analysis of the plasticity phenotypes suggests that BV supports adaptive plasticity while RO and BD promote a maladaptive pattern. The RO plasticity phenotype appeared more similar to adults with a high expression of GluA2, and the BD phenotypes were dominated by GABAA α1, highlighting that multiple plasticity phenotypes can underlie persistent poor acuity. After 2-4 days of BV, the plasticity phenotypes resembled normals, but only one feature, the GluN2A:GluA2 balance, returned to normal levels. Perhaps, balancing Hebbian (GluN2A) and homeostatic (GluA2) mechanisms is necessary for the recovery of vision.


Assuntos
Ambliopia/fisiopatologia , Plasticidade Neuronal/fisiologia , Receptores de GABA-A/metabolismo , Receptores de N-Metil-D-Aspartato/metabolismo , Visão Binocular/fisiologia , Visão Monocular/fisiologia , Córtex Visual/fisiopatologia , Ambliopia/metabolismo , Ambliopia/terapia , Animais , Gatos , Modelos Animais de Doenças , Feminino , Masculino , Neurônios/metabolismo , Fenótipo , Privação Sensorial/fisiologia , Acuidade Visual/fisiologia , Córtex Visual/metabolismo
3.
J Neurosci ; 37(25): 6031-6042, 2017 06 21.
Artigo em Inglês | MEDLINE | ID: mdl-28554889

RESUMO

Traditionally, human primary visual cortex (V1) has been thought to mature within the first few years of life, based on anatomical studies of synapse formation, and establishment of intracortical and intercortical connections. Human vision, however, develops well beyond the first few years. Previously, we found prolonged development of some GABAergic proteins in human V1 (Pinto et al., 2010). Yet as >80% of synapses in V1 are excitatory, it remains unanswered whether the majority of synapses regulating experience-dependent plasticity and receptive field properties develop late, like their inhibitory counterparts. To address this question, we used Western blotting of postmortem tissue from human V1 (12 female, 18 male) covering a range of ages. Then we quantified a set of postsynaptic glutamatergic proteins (PSD-95, GluA2, GluN1, GluN2A, GluN2B), calculated indices for functional pairs that are developmentally regulated (GluA2:GluN1; GluN2A:GluN2B), and determined interindividual variability. We found early loss of GluN1, prolonged development of PSD-95 and GluA2 into late childhood, protracted development of GluN2A until ∼40 years, and dramatic loss of GluN2A in aging. The GluA2:GluN1 index switched at ∼1 year, but the GluN2A:GluN2B index continued to shift until ∼40 year before changing back to GluN2B in aging. We also identified young childhood as a stage of heightened interindividual variability. The changes show that human V1 develops gradually through a series of five orchestrated stages, making it likely that V1 participates in visual development and plasticity across the lifespan.SIGNIFICANCE STATEMENT Anatomical structure of human V1 appears to mature early, but vision changes across the lifespan. This discrepancy has fostered two hypotheses: either other aspects of V1 continue changing, or later changes in visual perception depend on extrastriate areas. Previously, we showed that some GABAergic synaptic proteins change across the lifespan, but most synapses in V1 are excitatory leaving unanswered how they change. So we studied expression of glutamatergic proteins in human V1 to determine their development. Here we report prolonged maturation of glutamatergic proteins, with five stages that map onto life-long changes in human visual perception. Thus, the apparent discrepancy between development of structure and function may be explained by life-long synaptic changes in human V1.


Assuntos
Glutamatos/metabolismo , Proteínas do Tecido Nervoso/metabolismo , Córtex Visual/crescimento & desenvolvimento , Córtex Visual/metabolismo , Adolescente , Adulto , Idoso , Envelhecimento/fisiologia , Criança , Pré-Escolar , Proteína 4 Homóloga a Disks-Large , Feminino , Humanos , Lactente , Recém-Nascido , Peptídeos e Proteínas de Sinalização Intracelular , Masculino , Proteínas de Membrana , Pessoa de Meia-Idade , Rede Nervosa/crescimento & desenvolvimento , Rede Nervosa/metabolismo , Plasticidade Neuronal/fisiologia , Receptores de Glutamato/metabolismo , Sinapses/metabolismo , Adulto Jovem
4.
Europace ; 20(3): 451-458, 2018 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-28108547

RESUMO

Aims: Characterizing the differences in substrate and clinical outcome between heart failure (HF) and non-heart failure (non-HF) patients undergoing persistent atrial fibrillation (AF) ablation. Methods and results: Using complex fractionated electrograms (CFE) as a surrogate marker of substrate complexity, we compared the bi-atrial substrate in patients with persistent AF with and without HF, at baseline and after ablation, to determine its impact on clinical outcome. In this retrospective analysis of two prospective studies, 60 patients underwent de-novo step-wise left atrial (LA) ablation, 30 with normal left ventricular ejection fraction (LVEF) ≥ 50% (non-HF group) and 30 with LVEF ≤ 35% (HF group). Multiple high-density bi-atrial CFE maps were acquired along with AF cycle length (AFCL) at each procedural stage. Change in bi-atrial CFE areas, AFCL and outcome data were then compared. In the non-HF group, higher CFE-areas were found at baseline and at each step of the procedure in the LA. In both LA and the right atrium (RA), baseline and final CFE area were also higher in the non-HF group. Single procedure, arrhythmia-free survival at 1 year was higher in the HF group compared with the non-HF group (72% vs. 43%, log rank P = 0.04). Final total bi-atrial CFE area was an independent predictor of arrhythmia recurrence. Conclusions: CFE represents an important surrogate marker of atrial substrate complexity. The atrial substrate in persistent AF differs between HF and non-HF with the latter representing a more complex 'primary' bi-atrial myopathy. LA focussed ablation results in more extensive substrate modification in HF and better clinical outcomes as compared with non-HF.


Assuntos
Fibrilação Atrial/complicações , Técnicas Eletrofisiológicas Cardíacas , Sistema de Condução Cardíaco/fisiopatologia , Insuficiência Cardíaca/complicações , Potenciais de Ação , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Ablação por Cateter , Feminino , Sistema de Condução Cardíaco/cirurgia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Intervalo Livre de Progressão , Recidiva , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
5.
Europace ; 19(9): 1454-1462, 2017 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-28339601

RESUMO

AIMS: Initiating mechanisms of atrial fibrillation (AF) remain poorly understood, involving complex interaction between triggers and the atrial substrate. This study sought to classify the transitional phenomena, hypothesizing that there is consistency within and between patients in trigger-substrate interaction during transition to AF. METHODS AND RESULTS: Non-contact left atrial (LA) mapping was performed in 17 patients undergoing ablation for paroxysmal AF. All had spontaneous ectopy. Left atrial activation from the first ectopic to established AF was examined offline to characterize the initiating and transitional sequence of activation. In 57 fully mapped spontaneous AF initiations in 8 patients, all involved interaction of pulmonary venous/LA triggers with a septopulmonary line of block (SP-LOB) also evident in sinus rhythm, by 4 different transitional mechanisms characterized by (i) continuous focal firing: AF resulted from fragmentation of each ectopic wavefront through gaps in the SP-LOB and persisted only while focal firing continued (n = 18/32%) (ii) transient focal firing, wavefront fragmentation at the SP-LOB produced wavelet re-entry that persisted after cessation of an initiating ectopic source (n = 12/21%), (iii) of two separate interacting ectopic foci (n = 15/26%), or from (iv) transiently stable macroreentry (n = 12/21%), around the SP-LOB extending to the LA roof, resulting in progressive wavefront fragmentation. It was found that 79 ± 22% of each of the initiations in individual patients showed the same triggering mechanism. CONCLUSION: Onset of paroxysmal AF can be described by discrete mechanistic categories, all involving interaction of ectopic activity with a common SP-LOB. Within/between-patient consistency of initiations suggests constancy of the interacting triggers and substrate, and supports the concept of mechanistically tailored treatment.


Assuntos
Potenciais de Ação , Fibrilação Atrial/fisiopatologia , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca , Adulto , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Feminino , Sistema de Condução Cardíaco/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo
6.
Eur Heart J ; 37(46): 3470-3482, 2016 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-26935273

RESUMO

AIMS: The aim of this study was to analyse randomized controlled study and real-world outcomes of patients with non-valvular atrial fibrillation (NVAF) undergoing left atrial appendage closure (LAAC) with the Watchman device and to compare costs with available antithrombotic therapies. METHODS AND RESULTS: Registry data of LAAC from two centres were prospectively collected from 110 patients with NVAF at risk of stroke, suitable and unsuitable for long-term anticoagulation (age 71.3 ± 9.2 years, CHADS2 2.8 ± 1.2, CHA2DS2-VASc 4.5 ± 1.6, and HAS-BLED 3.8 ± 1.1). Outcomes from PROTECT AF and registry study LAAC were compared with warfarin, dabigatran, rivaroxaban, apixaban, aspirin, and no treatment using a network meta-analysis. Costs were estimated over a 10-year horizon. Uncertainty was assessed using sensitivity analyses. The procedural success rate was 92% (103/112). Follow-up was 24.1 ± 4.6 months, during which annual rates of stroke, major bleeding, and all-cause mortality were 0.9% (2/223 patient-years), 0.9% (2/223 patient-years), and 1.8% (4/223 patient-years), respectively. Anticoagulant therapy was successfully stopped in 91.2% (93/102) of implanted patients by 12 months. Registry study LAAC stroke and major bleeding rates were significantly lower than PROTECT AF results: mean absolute difference of stroke, 0.89% (P = 0.02) and major bleeding, 5.48% (P < 0.001). Left atrial appendage closure achieved cost parity between 4.9 years vs. dabigatran 110 mg and 8.4 years vs. warfarin. At 10 years, LAAC was cost-saving against all therapies (range £1162-£7194). CONCLUSION: Left atrial appendage closure in NVAF in a real-world setting may result in lower stroke and major bleeding rates than reported in LAAC clinical trials. Left atrial appendage closure in both settings achieves cost parity in a relatively short period of time and may offer substantial savings compared with current therapies. Savings are most pronounced among higher risk patients and those unsuitable for anticoagulation.


Assuntos
Apêndice Atrial , Anticoagulantes , Fibrilação Atrial , Humanos , Acidente Vascular Cerebral , Resultado do Tratamento , Varfarina
7.
Pacing Clin Electrophysiol ; 39(9): 926-34, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27436224

RESUMO

BACKGROUND: To investigate the effects of catheter ablation and rate control strategies on cardiac and inflammatory biomarkers in patients with heart failure and persistent atrial fibrillation (AF). METHODS: Patients were recruited from the ARC-HF trial (catheter Ablation vs Rate Control for management of persistent AF in Heart Failure, NCT00878384), which compared ablation with rate control for persistent AF in heart failure. B-type natriuretic peptide (BNP), midregional proatrial natriuretic peptide (MR-proANP), apelin, and interleukin-6 (IL-6) were assayed at baseline, 3 months, 6 months, and 12 months. The primary end point, analyzed per-protocol, was changed from baseline at 12 months. RESULTS: Of 52 recruited patients, 24 ablation and 25 rate control subjects were followed to 12 months. After 1.2 ± 0.5 procedures, sinus rhythm was present in 22 (92%) ablation patients; under rate control, rate criteria were achieved in 23 (96%) of 24 patients remaining in AF. At 12 months, MR-proANP fell significantly in the ablation arm (-106.0 pmol/L, interquartile range [IQR] -228.2 to -60.6) compared with rate control (-28.7 pmol/L, IQR -69 to +9.5, P = 0.028). BNP showed a similar trend toward reduction (P = 0.051), with no significant difference in apelin (P = 0.13) or IL-6 (P = 0.68). Changes in MR-proANP and BNP correlated with peak VO2 and ejection fraction, and MR-proANP additionally with quality-of-life score. CONCLUSIONS: Catheter ablation, compared with rate control, in patients with heart failure and persistent AF was associated with significant reduction in MR-proANP, which correlated with physiological and symptomatic improvement. Ablation-based rhythm control may induce beneficial cardiac remodeling, unrelated to changes in inflammatory state. This may have prognostic implications, which require confirmation by event end point studies.


Assuntos
Antiarrítmicos/uso terapêutico , Fibrilação Atrial/sangue , Fibrilação Atrial/terapia , Biomarcadores/sangue , Estimulação Cardíaca Artificial , Ablação por Cateter , Apelina , Fibrilação Atrial/diagnóstico , Fator Natriurético Atrial/sangue , Doença Crônica , Feminino , Insuficiência Cardíaca , Humanos , Peptídeos e Proteínas de Sinalização Intercelular/sangue , Interleucina-6/sangue , Masculino , Pessoa de Meia-Idade , Peptídeo Natriurético Encefálico/sangue , Avaliação de Resultados em Cuidados de Saúde/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento
8.
J Vis ; 15(1): 15.1.2, 2015 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-25572348

RESUMO

Abnormal early visual experience often leads to poor vision, a condition called amblyopia. Two recent approaches to treating amblyopia include binocular therapies and intensive visual training. These reflect the emerging view that amblyopia is a binocular deficit caused by increased neural noise and poor signal-in-noise integration. Most perceptual learning studies have used monocular training; however, a recent study has shown that binocular training is effective for improving acuity in adult human amblyopes. We used an animal model of amblyopia, based on monocular deprivation, to compare the effect of binocular training either during or after the critical period for ocular dominance plasticity (early binocular training vs. late binocular training). We used a high-contrast, orientation-in-noise stimulus to drive the visual cortex because neurophysiological findings suggest that binocular training may allow the nondeprived eye to teach the deprived eye's circuits to function. We found that both early and late binocular training promoted good visual recovery. Surprisingly, we found that monocular deprivation caused a permanent deficit in the vision of both eyes, which became evident only as a sleeper effect following many weeks of visual training.


Assuntos
Ambliopia/terapia , Modelos Animais de Doenças , Aprendizagem/fisiologia , Recuperação de Função Fisiológica/fisiologia , Privação Sensorial/fisiologia , Visão Binocular/fisiologia , Visão Monocular/fisiologia , Ambliopia/fisiopatologia , Animais , Gatos , Dominância Ocular
9.
Heart Rhythm ; 2024 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-38763376

RESUMO

BACKGROUND: Long-term clinical outcomes of catheter ablation (CA) compared to thoracoscopic surgical ablation (SA) to treat patients with long-standing persistent atrial fibrillation (LSPAF) are not known. OBJECTIVE: The purpose of this study was to compare the long-term (36-month) clinical efficacy, quality of life, and cost-effectiveness of SA and CA in LSPAF. METHODS: Participants were followed up for 3 years using implantable loop recorders and questionnaires to assess the change in quality of life. Intention-to-treat analyses were used to report the findings. RESULTS: Of the 115 patients with LSPAF treated, 104 (90.4%) completed 36-month follow-up [CA: n = 57 (95%); SA: n = 47 (85%)]. After a single procedure without antiarrhythmic drugs, 7 patients (12%) in the CA arm and 5 (11%) in the SA arm [hazard ratio 1.22; 95% confidence interval (CI) 0.81-1.83; P = .41] were free from atrial fibrillation/tachycardia (AF/AT) ≥30 seconds at 36 months. Thirty-three patients (58%) in the CA arm and 26 (55%) in the SA arm (hazard ratio 1.04; 95% CI 0.57-1.88; P = .91) had their AF/AT burden reduced by ≥75%. The overall impact on health-related quality of life was similar, with mean quality-adjusted life year estimates of 2.45 (95% CI 2.31-2.59) for CA and 2.32 (95% CI 2.13-2.52) for SA. Estimated costs were higher for SA (mean £24,682; 95% CI £21,746-£27,618) than for CA (mean £18,002; 95% CI £15,422-£20,581). CONCLUSION: In symptomatic LSPAF, CA and SA were equally effective at achieving arrhythmia outcomes (freedom from AF/AT ≥30 seconds and ≥75% burden reduction) after a single procedure without antiarrhythmic drugs. However, SA is significantly more costly than CA. TRIAL REGISTRATION: ClinicalTrials.gov identifier NCT04280042.

10.
Pacing Clin Electrophysiol ; 36(6): 757-63, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23438182

RESUMO

BACKGROUND: The impact of recently introduced asymmetric bidirectional ablation catheters on procedural parameters and acute success rates of ablation procedures is unknown. METHODS: We retrospectively analyzed data regarding ablations using a novel bidirectional catheter in a tertiary cardiac center and compared these in 1:5 ratio with a control group of procedures matched for age, gender, operator, and ablation type. RESULTS: A total of 50 cases and 250 controls of median age 60 (50-68) years were studied. Structural heart disease was equally prevalent in both groups (39%) while history of previous ablations was more common in the study arm (54% vs 30%, P = 0.001). Most of the ablation cases were for atrial fibrillation (46%), followed by atrial tachycardia (28%), supraventricular tachycardia (12%), and ventricular tachycardia (14%). Median procedure duration was 128 (52-147) minutes with the bidirectional, versus 143 (105-200) minutes with the conventional catheter (P = 0.232), and median fluoroscopy time was 17 (10-34) minutes versus 23 (12-39) minutes, respectively (P = 0.988). There was a trend toward a lower procedure duration for the atrial tachycardia ablations, 89 (52-147) minutes versus 130 (100-210) minutes, P = 0.064. The procedure was successfully completed in 96% of the bidirectional versus 84% of the control cases (P = 0.151). A negative correlation was observed between the relative fluoroscopy duration and the case number (r = -0.312, P = 0.028), reflecting the learning curve for the bidirectional catheter. CONCLUSIONS: The introduction of the bidirectional catheter resulted in no prolongation of procedure parameters and similar success rates, while there was a trend toward a lower procedure duration for atrial tachycardia ablations.


Assuntos
Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/cirurgia , Ablação por Cateter/instrumentação , Ablação por Cateter/estatística & dados numéricos , Fluoroscopia/estatística & dados numéricos , Duração da Cirurgia , Idoso , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/diagnóstico por imagem , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Londres/epidemiologia , Masculino , Pessoa de Meia-Idade , Prevalência , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
11.
Heart Rhythm ; 19(1): 61-69, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34583060

RESUMO

BACKGROUND: A novel aggregated multiposition noncontact mapping (AMP-NCM) algorithm is proposed to diagnose cardiac arrhythmias. OBJECTIVE: The purpose of this study was to computationally determine an accuracy threshold and to compare the accuracy and clinical utility of AMP-NCM to gold standard contact mapping. METHODS: In a cellular automata model, the number of catheter positions and chamber coverage were varied to establish accuracy requirements for clinically relevant AMP-NCM. This guided the clinical study protocol. In a prospective cohort of patients with atrial tachycardia (AT), noncontact mapping (NCM) recordings from a single position (SP) and multiple positions were compared to contact mapping with a high-density multipolar catheter using morphology and timing differences of reconstructed signals. Identification of AT mechanisms and ablation targets using both AMP-NCM and contact mapping were randomly evaluated by 5 blinded reviewers. RESULTS: AMP-NCM accuracy was asymptotic at 60 catheter positions in computational modeling. Twenty patients (age 65 ± 12 years; 19 male) with 26 ATs (5 focal, 21 reentrant) were studied. Morphologic correlation of signals derived from AMP-NCM was significantly better than those from SP-NCM compared to contact signals (median 0.93 vs 0.76; P <.001). AMP-NCM generated maps more rapidly than contact mapping (3 ± 1 minutes vs 13 ± 6 minutes; P <.001) and correctly diagnosed AT mechanisms in 25 of 26 maps (96%). Overall, 80% of arrhythmia mechanisms were correctly identified using AMP-NCM by blinded reviewers. CONCLUSION: Once 60 catheter positions were achieved, AMP-NCM successfully diagnosed mechanisms of AT and identified treatment sites equal to gold standard contact mapping in 3 minutes of procedural time.


Assuntos
Simulação por Computador , Mapeamento Epicárdico , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/fisiopatologia , Idoso , Algoritmos , Feminino , Humanos , Masculino , Estudos Prospectivos
12.
Heart Rhythm ; 18(6): 862-870, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33610744

RESUMO

BACKGROUND: Noncontact charge-density mapping allows rapid real-time global mapping of atrial fibrillation (AF), offering the opportunity for a personalized ablation strategy. OBJECTIVE: The purpose of this study was to compare the 2-year outcome of an individualized strategy consisting of pulmonary vein isolation (PVI) plus core-to-boundary ablation (targeting the conduction pattern core with an extension to the nearest nonconducting boundary) guided by charge-density mapping, with an empirical PVI plus posterior wall electrical isolation (PWI) strategy. METHODS: Forty patients (age 62 ± 12 years; 29 male) with persistent AF (10 ± 5 months) prospectively underwent charge-density mapping-guided PVI, followed by core-to-boundary stepwise ablation until termination of AF or depletion of identified cores. Freedom from AF/atrial tachycardia (AT) at 24 months was compared with a propensity score-matched control group of 80 patients with empirical PVI + PWI guided by conventional contact mapping. RESULTS: Acute AF termination occurred in 8 of 40 patients after charge-density mapping-guided PVI alone and in 21 of the remaining 32 patients after core-to-boundary ablation in the study cohort, compared with 8 of 80 (10%) in the control cohort (P <.001). On average, 2.2 ± 0.6 cores were ablated post-PVI before acute AF termination. At 24 months, freedom from AF/AT after a single procedure was 68% in the study group vs 46% in the control group (P = .043). CONCLUSION: An individualized ablation strategy consisting of PVI plus core-to-boundary ablation guided by noncontact charge-density mapping is a feasible and effective strategy for treating persistent AF, with a favorable 24-month outcome.


Assuntos
Fibrilação Atrial/cirurgia , Mapeamento Potencial de Superfície Corporal/métodos , Ablação por Cateter/normas , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca/fisiologia , Veias Pulmonares/cirurgia , Cirurgia Assistida por Computador/normas , Fibrilação Atrial/fisiopatologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Pontuação de Propensão , Estudos Prospectivos , Recidiva , Fatores de Tempo , Resultado do Tratamento
13.
Front Cell Neurosci ; 14: 245, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33192303

RESUMO

Many neural mechanisms regulate experience-dependent plasticity in the visual cortex (V1), and new techniques for quantifying large numbers of proteins or genes are transforming how plasticity is studied into the era of big data. With those large data sets comes the challenge of extracting biologically meaningful results about visual plasticity from data-driven analytical methods designed for high-dimensional data. In other areas of neuroscience, high-information content methodologies are revealing more subtle aspects of neural development and individual variations that give rise to a richer picture of brain disorders. We have developed an approach for studying V1 plasticity that takes advantage of the known functions of many synaptic proteins for regulating visual plasticity. We use that knowledge to rebrand protein measurements into plasticity features and combine those into a plasticity phenotype. Here, we provide a primer for analyzing experience-dependent plasticity in V1 using example R code to identify high-dimensional changes in a group of proteins. We describe using PCA to classify high-dimensional plasticity features and use them to construct a plasticity phenotype. In the examples, we show how to use this analytical framework to study and compare experience-dependent development and plasticity of V1 and apply the plasticity phenotype to translational research questions. We include an R package "PlasticityPhenotypes" that aggregates the coding packages and custom code written in RStudio to construct and analyze plasticity phenotypes.

14.
J Arrhythm ; 36(4): 692-702, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32782641

RESUMO

BACKGROUND: Global simultaneous recording of atrial activation during atrial fibrillation (AF) can elucidate underlying mechanisms contributing to AF maintenance. A better understanding of these mechanisms may allow for an individualized ablation strategy to treat persistent AF. The study aims to characterize left atrial endocardial activation patterns during AF using noncontact charge-density mapping. METHODS: Twenty-five patients with persistent AF were studied. Activation patterns were characterized into three subtypes: (i) focal with centrifugal activation (FCA); (ii) localized rotational activation (LRA); and (iii) localized irregular activation (LIA). Continuous activation patterns were analyzed and distributed in 18 defined regions in the left atrium. RESULTS: A total of 144 AF segments with 1068 activation patterns were analyzed. The most common pattern during AF was LIA (63%) which consists of four disparate features of activation: slow conduction (45%), pivoting (30%), collision (16%), and acceleration (7%). LRA was the second-most common pattern (20%). FCA accounted for 17% of all activations, arising frequently from the pulmonary veins (PVs)/ostia. A majority of patients (24/25; 96%) showed continuous and highly dynamic patterns of activation comprising multiple combinations of FCA, LRA, and LIA, transitioning from one to the other without a discernible order. Preferential conduction areas were typically seen in the mid-anterior (48%) and lower-posterior (40%) walls. CONCLUSION: Atrial fibrillation is characterized by heterogeneous activation patterns identified in PV-ostia and non-PV regions throughout the LA at varying locations between individuals. Clinical implications of individualized ablation strategies guided by charge-density mapping need to be determined.

15.
JACC Clin Electrophysiol ; 6(2): 171-181, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-32081219

RESUMO

OBJECTIVES: This study sought to validate the accuracy of noncontact electrograms against contact electrograms in the left atrium during sinus rhythm (SR) and atrial fibrillation (AF). BACKGROUND: Noncontact mapping offers the opportunity to assess global cardiac activation in the chamber of interest. A novel noncontact mapping system, which records intracardiac voltage to derive cellular charge sources (dipole density), allows real-time mapping of AF to guide ablation. METHODS: Noncontact and contact unipolar electrogram pairs were recorded simultaneously from multiple locations. Morphology correlation and timing difference of reconstructed electrograms obtained from a noncontact catheter were compared with those from contact electrograms obtained from a contact catheter at the same endocardial locations. RESULTS: A total of 796 electrogram pairs in SR and 969 electrogram pairs in AF were compared from 20 patients with persistent AF. The median morphology correlation and timing difference (ms) in SR was 0.85 (interquartile range [IQR]: 0.71 to 0.94) and 6.4 ms (IQR: 2.6 to 17.1 ms); in AF was 0.79 (IQR: 0.69 to 0.88) and 14.4 ms (IQR: 6.7 to 26.2 ms), respectively. The correlation was stronger and the timing difference was less when the radial distance (r) from the noncontact catheter center to the endocardium was ≤ 40 versus > 40 mm; 0.87 (IQR: 0.72 to 0.94) versus 0.73 (IQR: 0.56 to 0.88) and 5.7 ms (IQR: 2.6 to 15.4 ms) versus 15.1 ms (IQR: 4.1 to 27.7 ms); p < 0.01 when in SR; 0.81 (IQR: 0.69 to 0.89) versus 0.67 (IQR: 0.45 to 0.82) and 12.3 ms (IQR: 5.9 to 21.8 ms) versus 28.3 ms (IQR: 16.2 to 36.0 ms); p < 0.01 when in AF. CONCLUSIONS: This novel noncontact dipole density mapping system provides comparable reconstructed atrial electrogram measurements in SR or AF in human left atrium when the anatomical site of interest is ≤40 mm from the mapping catheter.


Assuntos
Fibrilação Atrial/fisiopatologia , Técnicas Eletrofisiológicas Cardíacas/métodos , Átrios do Coração/fisiopatologia , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas/normas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
16.
Bioorg Med Chem Lett ; 19(17): 4916-9, 2009 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-19664922

RESUMO

High throughput screening of the corporate compound collection led to the identification of a novel series of 2-amino-9-aryl-3-cyano-4-methyl-7-oxo-6,7,8,9-tetrahydropyrido[2',3':4,5]thieno[2,3-b]pyridine derivatives as selective PR agonists. Initial SAR exploration leading to potent and selective agonists 9 and 11, X-ray crystal structure of 9 bound to PR-LBD and preliminary developability data are described.


Assuntos
Piridinas/química , Piridonas/química , Receptores de Progesterona/agonistas , Tiofenos/química , Animais , Sítios de Ligação , Simulação por Computador , Cristalografia por Raios X , Humanos , Microssomos Hepáticos/metabolismo , Conformação Molecular , Piridinas/síntese química , Piridinas/farmacologia , Piridonas/síntese química , Piridonas/farmacologia , Ratos , Receptores de Progesterona/metabolismo , Relação Estrutura-Atividade , Tiofenos/síntese química , Tiofenos/farmacologia
17.
J Vis ; 7(1): 9, 2007 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-17461677

RESUMO

Previous psychophysical studies have shown that oriented signals are pooled over space to support better perceptual performance. We have investigated whether oriented signals may also be pooled over time. Using an orientation-in-noise paradigm, the threshold to discriminate large orientation differences was measured as the minimum amount of signal required to discriminate an oriented stimulus from unoriented noise. Discrimination thresholds were better with dynamic stimuli, containing multiple independent samples over time, than with static stimuli presented for an equal duration. Thresholds for dynamic stimuli showed gradual improvement from very brief (12 ms) to remarkably long presentation times (>4 s). Spatial integration of orientation signals is very efficient and can be understood in terms of a model based on signal detection theory, with performance limited by early and late stages of intrinsic noise. The nature of temporal integration is different, however, and is more consistent with probability summation of the outputs from low-level orientation detectors operating at a very brief timescale but whose outputs can be combined over a very long duration to yield better perceptual performance.


Assuntos
Orientação/fisiologia , Artefatos , Simulação por Computador , Limiar Diferencial , Discriminação Psicológica , Humanos , Modelos Psicológicos , Estimulação Luminosa , Detecção de Sinal Psicológico , Percepção Espacial/fisiologia , Fatores de Tempo
18.
J Environ Radioact ; 96(1-3): 63-74, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17512643

RESUMO

This paper presents new data on the distribution of long-lived radionuclides in Irish Sea subtidal sediments, contaminated as a result of the BNFL Sellafield discharges. The results from different sampling campaigns in 1999 have been combined to assess the extent of radionuclide mobility relative to earlier surveys, in both the eastern and western Irish Sea areas, and to investigate changes in radionuclide distribution over time. The results appear to confirm the trend of continuing re-distribution and transfer of contamination away from the English coast. West of the Isle of Man, radionuclide concentrations and inventories have remained more or less constant. The inventory of radionuclides in sandy sediments in the eastern Irish Sea is still under-represented by current sampling, but could be improved by deeper and more extensive vibrocoring.


Assuntos
Monitoramento de Radiação/métodos , Radioisótopos/análise , Movimentos da Água , Poluentes Radioativos da Água/análise , Amerício/análise , Radioisótopos de Césio/análise , Sedimentos Geológicos , Irlanda , Oceanos e Mares , Plutônio/análise , Poluentes Radioativos , Resíduos Radioativos , Reino Unido , Água , Contaminação Radioativa da Água
19.
Heart Rhythm ; 14(11): 1596-1603, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-29101964

RESUMO

BACKGROUND: Catheter ablation (CA) outcomes for long-standing persistent atrial fibrillation (LSPAF) remain suboptimal. Thoracoscopic surgical ablation (SA) provides an alternative approach in this difficult to treat cohort. OBJECTIVE: To compare electrophysiological (EP) guided thoracoscopic SA with percutaneous CA as the first-line strategy in the treatment of LSPAF. METHODS: Fifty-one patients with de novo symptomatic LSPAF were recruited. Twenty-six patients underwent electrophysiologically guided thoracoscopic SA. Conduction block was tested for all lesions intraoperatively by an independent electrophysiologist. In the CA group, 25 consecutive patients underwent stepwise left atrial (LA) ablation. The primary end point was single-procedure freedom from atrial fibrillation (AF) and atrial tachycardia (AT) lasting >30 seconds without antiarrhythmic drugs at 12 months. RESULTS: Single- and multiprocedure freedom from AF/AT was higher in the SA group than in the CA group: 19 of 26 patients (73%) vs 8 of 25 patients (32%) (P = .003) and 20 of 26 patients (77%) vs 15 of 25 patients (60%) (P = .19), respectively. Testing of the SA lesion set by an electrophysiologist increased the success rate in achieving acute conduction block by 19%. In the SA group, complications were experienced by 7 of 26 patients (27%) vs 2 of 25 patients (8%) in the CA group (P = .07). CONCLUSION: In LSPAF, meticulous electrophysiologically guided thoracoscopic SA as a first-line strategy may provide excellent single-procedure success rates as compared with those of CA, but there is an increased up-front risk of nonfatal complications.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Eletrocardiografia Ambulatorial/métodos , Técnicas Eletrofisiológicas Cardíacas/métodos , Frequência Cardíaca/fisiologia , Cirurgia Assistida por Computador/métodos , Toracoscopia/métodos , Idoso , Fibrilação Atrial/fisiopatologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento
20.
Heart Rhythm ; 14(2): 176-183, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-27867071

RESUMO

BACKGROUND: The mapping of ventricular arrhythmias in humans using a minibasket 64-electrode catheter paired with a novel automatic mapping system (Rhythmia) has not been evaluated. OBJECTIVE: The purpose of this study was to evaluate the safety and efficacy of mapping ventricular arrhythmias and clinical outcomes after ablation using this system. METHODS: Electroanatomic maps for ventricular arrhythmias were obtained during 20 consecutive procedures in 19 patients (12 with ventricular tachycardia [VT] and 2 with ventricular ectopy [VE]). High-density maps were acquired using automatic beat acceptance and automatic system annotation of electrograms. RESULTS: Forty-seven electroanatomic maps (including 3 right ventricular and 9 epicardial maps) were obtained. Left ventricular endocardial mapping by transseptal (n = 13) and/or transaortic (n = 11) access was safe with no complications related to the minibasket catheter. VT substrate maps (n = 14; median 10,184 points) consistently demonstrated late potentials with high resolution. VT activation maps (n = 25; median 6401 points) obtained by automatic annotation included 7 complete maps (covering ≥90% of the tachycardia cycle length) in 5 patients in whom the entire VT circuit was accurately visualized. VE timing maps (n = 8) successfully localized the origin of VEs in all, with all accepted beats consistent with clinical VEs. Over a median follow-up of 10 months, no arrhythmia recurrence was noted in 75% after VT ablation and 86% after VE ablation. CONCLUSION: In this first human experience for ventricular arrhythmias using this system, ultra-high-density maps were created rapidly and safely, with a reliable automatic annotation of VT and consistent recording of abnormal electrograms. Medium-term outcomes after ablation were encouraging. Further larger studies are needed to validate these findings.


Assuntos
Mapeamento Potencial de Superfície Corporal , Cateteres Cardíacos , Ablação por Cateter/métodos , Endocárdio , Ventrículos do Coração , Taquicardia Ventricular , Adulto , Mapeamento Potencial de Superfície Corporal/instrumentação , Mapeamento Potencial de Superfície Corporal/métodos , Técnicas Eletrofisiológicas Cardíacas/métodos , Endocárdio/diagnóstico por imagem , Endocárdio/fisiopatologia , Desenho de Equipamento , Feminino , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Humanos , Aumento da Imagem/instrumentação , Aumento da Imagem/métodos , Masculino , Teste de Materiais , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/cirurgia
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa