Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Blood Press Monit ; 29(4): 167-172, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38465772

RESUMO

OBJECTIVE: Understanding of how oscillometric waveforms (OMW) vary between pregnant and nonpregnant individuals remains low. An exploratory analysis was completed to assess for quantitative and qualitative changes in OMW and oscillometric envelope features in pregnancy. DESIGN AND METHODS: Eighteen pregnant individuals (over 20 weeks gestational age) and healthy, nonpregnant (HNP) women were recruited. Six HNP were matched to six healthy pregnant (HP) women, and six pregnant women with a hypertensive disorder of pregnancy (HDP) by age, arm circumference, and cuff size. Blood pressure measurements were completed per the International Organization for Standardization (ISO) protocol using a custom-built oscillometric device as the test device and two-observer mercury auscultation as the reference measurement. Auscultatory blood pressure and blood pressure derived from slope-based and fixed ratio algorithms were determined. OMW and envelope features were compared among groups. RESULTS: In HNP, HP, and HDP groups respectively: mean auscultatory blood pressure (systolic mean ± SD/diastolic mean ± SD) was 103.4 ±â€…12.2/67.1 ±â€…7.9; 109.5 ±â€…3.1/58.1 ±â€…6.4; 135.6 ±â€…18.9/85.1 ±â€…14.2 mmHg. HDP had significantly higher auscultatory systolic and diastolic blood pressure than the HP group ( P  = 0.001). The pregnant groups had a lower average pulse width (mean ± SD: HNP = 0.8 ±â€…0 s, HP = 0.6 ±â€…0.1 s, HDP = 0.6 ±â€…0.1 s; HP vs. HNP mean difference [adjusted P value]: 0.2 [ P  = 0.004], HDP vs. HNP 0.1 [ P  = 0.018]) compared with the HNP group. The HDP group had a larger area under the OMW envelope than the HNP group (mean ± SD: HNP = 22.6 ±â€…3.4; HDP = 28.5 ±â€…4.2; HDP vs. HNP mean difference [adjusted P value]: 5.9 P  = 0.05). CONCLUSION: In this exploratory work, differences in the OMW morphology and parameters were found in pregnancy and in hypertensive disorders of pregnancy compared with healthy controls. Even small differences may have important implications in algorithm development; further work comparing OMW envelopes in pregnancy is needed to optimize the algorithms used to determine blood pressure in pregnancy.


Assuntos
Hipertensão Induzida pela Gravidez , Oscilometria , Humanos , Feminino , Gravidez , Adulto , Hipertensão Induzida pela Gravidez/fisiopatologia , Oscilometria/instrumentação , Pressão Sanguínea , Determinação da Pressão Arterial/métodos , Determinação da Pressão Arterial/instrumentação
2.
Am J Hypertens ; 34(2): 157-162, 2021 03 11.
Artigo em Inglês | MEDLINE | ID: mdl-32856693

RESUMO

BACKGROUND: Oscillometric blood pressure (BP) devices are typically labeled for use up to 40 °C. Many geographic regions have ambient temperatures exceeding 40 °C. We assessed the effect of increased ambient temperature (40-55 °C) on simulator-derived oscillometric BP measurement. METHODS: Three Omron BP769CAN devices, 3 A&D Medical UA-651BLE devices, and accompanying cuffs were used. A custom heat chamber heated each device to the specified temperature. A noninvasive BP simulator was used to take 3 measurements with each device at differing temperatures (22, 40, 45, 50, and 55 °C) and BP thresholds: 80/50, 100/60, 120/80, 140/90, 160/110, and 180/130 mm Hg. Using each device as its own control (22 °C), we determined the relative differences in mean BP for each device at each temperature and BP setting, assessed graphical trends with increasing temperature, and examined variability. RESULTS: Graphical trends of mean simulator-subtracted BP differences from room temperature showed no discernable pattern, with differences clustered around zero. Overall mean difference in BP (combined elevated temperatures minus room temperature) was -0.8 ± 2.1 (systolic ± SD)/1.2 ± 3.5 (diastolic ± SD) mm Hg for the A&D device and 0.2 ± 0.4 (systolic ± SD)/-0.1 ± 0.1 (diastolic ± SD) mm Hg for the Omron. All individual elevated temperature differences (elevated temperature minus room temperature) except A&D diastolic BP at 50 °C were within 5 mm Hg. CONCLUSIONS: In this simulator-based study assessing within-device differences, higher ambient temperatures resulted in oscillometric BP measurements that were comparable to those performed at room temperature.


Assuntos
Pressão Sanguínea , Temperatura , Pressão Sanguínea/fisiologia , Determinação da Pressão Arterial , Humanos , Oscilometria , Esfigmomanômetros
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa