Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Eur J Neurol ; 31(2): e16141, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37969021

RESUMO

BACKGROUND AND PURPOSE: The role of high-resolution nerve ultrasound (HRUS) and corneal confocal microscopy (CCM) in the early detection of taxane-induced polyneuropathy (TIPN) is unclear. The present prospective longitudinal controlled observational pilot study estimates the role of HRUS and CCM in the early diagnosis of TIPN in breast cancer patients. METHODS: Fifteen breast cancer patients receiving paclitaxel and 15 healthy age matched controls were included. Visits before and 3 weeks, 8 weeks and 6 months after treatment included clinical examination, the total neuropathy score, nerve conduction studies (NCS), monocular CCM including corneal nerve fibre length, density and branching and HRUS of bilateral median, ulnar, radial, tibial, peroneal and sural nerves. Patients were compared between different visits and to healthy controls. RESULTS: Total neuropathy score increased from 2.2 at baseline to 5.8 (p < 0.001) at week 8. NCS showed a decreased sensory amplitude in the sural, radial, ulnar and median nerve after 6 months (p < 0.001). HRUS revealed a significant increase of cross-sectional area in the sural nerve (p = 0.004), the median nerve (p = 0.003) at the carpal tunnel and the ulnar nerve in the forearm (p = 0.006) after 6 months. CCM showed no changes at different visits. CONCLUSIONS: Corneal confocal microscopy and HRUS do not detect early signs of TIPN during the paclitaxel treatment period. HRUS and NCS might detect congruent signs of an axonal, predominantly sensory polyneuropathy after 6 months. The clinical examination remains the most sensitive tool in the early detection of TIPN in breast cancer patients.


Assuntos
Neoplasias da Mama , Neuropatias Diabéticas , Doenças do Sistema Nervoso Periférico , Polineuropatias , Feminino , Humanos , Neoplasias da Mama/tratamento farmacológico , Neuropatias Diabéticas/diagnóstico , Microscopia Confocal , Condução Nervosa/fisiologia , Paclitaxel , Doenças do Sistema Nervoso Periférico/induzido quimicamente , Doenças do Sistema Nervoso Periférico/diagnóstico por imagem , Polineuropatias/induzido quimicamente , Polineuropatias/diagnóstico por imagem , Estudos Prospectivos , Taxoides/efeitos adversos , Projetos Piloto
2.
F S Rep ; 5(1): 63-71, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38524212

RESUMO

Objective: To validate the performance of our laboratory-developed whole-genome screening assay within clinical preimplantation genetic testing environments. Design: Perform a laboratory-developed whole-genome assay on both cell lines and trophectoderm biopsies, subsequently employing the next-generation sequencing procedure to reach a sequencing depth of 30X. Adhere to the Genome Analysis Toolkit best practices for accuracy, sensitivity, specificity, and precision calculations by comparing samples with references. Our assay was then applied to cell lines and biopsies harboring known pathogenic variants, aiming to ascertain these changes solely from the next-generation sequencing data, independent of parental genome information. Settings: Clinical laboratory. Patients: Coriell cell lines and research embryos with known chromosomal or genetic variants. Research trophectoderm biopsies from a couple that are heterozygous carriers for distinct variants in the same autosomal recessive gene (HOGA1). Intervention: Not applicable. Main Outcome Measures: Accuracy, sensitivity, specificity, and precision were assessed by comparing the samples to their references. For samples with known variants, we calculated our sensitivity to detecting established variants. For the research embryos, noncarrier, carrier, and compound heterozygous states of inherited HOGA1 variants were distinguished independently of parental samples. Results: Amplification of DNA from cell lines and embryos yielded success rates exceeding 99.9% and 98.2%, respectively, although maintaining an accuracy of >99.9% for aneuploidy assessment. The accuracy (99.99%), specificity (99.99%), sensitivity (98.0%), and precision (98.1%) of amplified genome in the bottle (reference NA12878) and embryo biopsies were comparable to results on genomic DNA, including mitochondrial heteroplasmy. Using our assay, we achieved >99.99% sensitivity when examining samples with known chromosomal and genetic variants. This encompassed pathogenic CFTR, BRCA1, and other variants, along with uniparental isodisomies and microdeletions such as DiGeorge syndrome. Our research study identified noncarrier, carrier, and compound heterozygous states within trophectoderm biopsies while simultaneously screening for 1,300 other severe monogenic diseases. Conclusion: To our knowledge, this is the first clinical validation of whole-genome embryo screening. In this study, we demonstrated high accuracy for aneuploidy calls (>99.9%) and genetic variants (99.99%), even in the absence of parental genomes. This assay demonstrates advancements in genomic screening and an extended scope for testing capabilities in the realm of preimplantation genetic testing.

3.
Diagnostics (Basel) ; 11(11)2021 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-34829481

RESUMO

Currently, there is no standardized method to evaluate operator reliability in nerve ultrasound. A short prospective protocol using Bland-Altman analysis was developed to assess the level of agreement between operators with different expertise levels. A control rater without experience in nerve ultrasound, three novices after two months of training, an experienced rater with two years of experience, and a reference rater performed blinded ultrasound examinations of the left median and ulnar nerve in 42 nerve sites in healthy volunteers. The precision of Bland-Altman agreement analysis was tested using the Preiss-Fisher procedure. Intraclass correlation coefficients (ICC), coefficients of variation, and Bland-Altman limits of agreement were calculated. The sample size calculation and Preiss-Fisher procedure showed a sufficient precision of Bland-Altman agreement analysis. Limits of agreement of all trained novices ranged from 2.0 to 2.9 mm2 and were within the test's maximum tolerated difference. Ninety-five percent confidence intervals of limits of agreement revealed a higher precision in the experienced rater's measurements. Operator reliability in nerve ultrasound of the median and ulnar nerve arm nerves can be evaluated with a short prospective controlled protocol using Bland-Altman statistics, allowing a clear distinction between an untrained rater, trained novices after two months of training, and an experienced rater.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa