Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 80
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Pacing Clin Electrophysiol ; 47(2): 260-264, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-37221915

RESUMO

The His-bundle has several locations from which conduction system pacing can be achieved. Some locations offer better sensing, thresholds and paced QRS durations. Existing techniques to aid repositioning of an already deployed, but sub-optimally placed lead, include either simple memory of the initial lead position combined with its observation on an x-ray review screen or utilizing an additional vascular access and pacing lead with the first lead serving as a real-time marker (Two-lead technique). We describe a novel, readily available, cost-efficient, imaging-based approach to assist in the re-positioning of a pacing lead for His-bundle pacing (the Image Overlay Technique).


Assuntos
Estimulação Cardíaca Artificial , Eletrocardiografia , Humanos , Estimulação Cardíaca Artificial/métodos , Eletrocardiografia/métodos , Sistema de Condução Cardíaco , Doença do Sistema de Condução Cardíaco , Fascículo Atrioventricular , Resultado do Tratamento
2.
Europace ; 25(3): 1060-1067, 2023 03 30.
Artigo em Inglês | MEDLINE | ID: mdl-36734205

RESUMO

AIMS: Left bundle branch area pacing (LBBAP) is a promising method for delivering cardiac resynchronization therapy (CRT), but its relative physiological effectiveness compared with His bundle pacing (HBP) is unknown. We conducted a within-patient comparison of HBP, LBBAP, and biventricular pacing (BVP). METHODS AND RESULTS: Patients referred for CRT were recruited. We assessed electrical response using non-invasive mapping, and acute haemodynamic response using a high-precision haemodynamic protocol. Nineteen patients were recruited: 14 male, mean LVEF of 30%. Twelve had time for BVP measurements. All three modalities reduced total ventricular activation time (TVAT), (ΔTVATHBP -43 ± 14 ms and ΔTVATLBBAP -35 ± 20 ms vs. ΔTVATBVP -19 ± 30 ms, P = 0.03 and P = 0.1, respectively). HBP produced a significantly greater reduction in TVAT compared with LBBAP in all 19 patients (-46 ± 15 ms, -36 ± 17 ms, P = 0.03). His bundle pacing and LBBAP reduced left ventricular activation time (LVAT) more than BVP (ΔLVATHBP -43 ± 16 ms, P < 0.01 vs. BVP, ΔLVATLBBAP -45 ± 17 ms, P < 0.01 vs. BVP, ΔLVATBVP -13 ± 36 ms), with no difference between HBP and LBBAP (P = 0.65). Acute systolic blood pressure was increased by all three modalities. In the 12 with BVP, greater improvement was seen with HBP and LBBAP (6.4 ± 3.8 mmHg BVP, 8.1 ± 3.8 mmHg HBP, P = 0.02 vs. BVP and 8.4 ± 8.2 mmHg for LBBAP, P = 0.3 vs. BVP), with no difference between HBP and LBBAP (P = 0.8). CONCLUSION: HBP delivered better ventricular resynchronization than LBBAP because right ventricular activation was slower during LBBAP. But LBBAP was not inferior to HBP with respect to LV electrical resynchronization and acute haemodynamic response.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Masculino , Fascículo Atrioventricular , Terapia de Ressincronização Cardíaca/efeitos adversos , Terapia de Ressincronização Cardíaca/métodos , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/terapia , Eletrocardiografia/métodos , Resultado do Tratamento , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Hemodinâmica , Estimulação Cardíaca Artificial/métodos
3.
Europace ; 25(2): 341-350, 2023 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-36305545

RESUMO

AIMS: The effect of atrial fibrillation catheter ablation on cardiovascular outcomes in heart failure is an important outstanding research question. We undertook a meta-analysis of randomized controlled trials comparing ablation to medical therapy in patients with AF and heart failure. METHODS AND RESULTS: We systematically identified all trials comparing catheter ablation to medical therapy in patients with heart failure and atrial fibrillation. The pre-specified primary endpoint was all-cause mortality in trials with at least 2 years of follow-up. The secondary endpoint was heart failure hospitalization. Sensitivity analyses were performed for trials with any follow-up and trials deemed at low risk of bias. Eight trials (1390 patients) were included. Seven hundred and seven patients were randomized to catheter ablation and 683 to medical therapy. In the primary analysis (three trials, n = 977), catheter ablation reduced mortality compared with medical therapy [relative risk (RR): 0.61, 95% confidence interval (CI): 0.44 to 0.84, P = 0.003]. Catheter ablation also reduced heart failure hospitalizations compared with medical therapy (RR: 0.60, 95% CI: 0.49-0.74, P < 0.001). The effect on stroke was not statistically significant (RR: 0.62, 95% CI: 0.28-1.37, P = 0.237). There was low heterogeneity between studies. Sensitivity analyses were consistent with the primary analyses. CONCLUSION: In patients with atrial fibrillation and heart failure, catheter ablation reduces mortality and the occurrence of heart failure hospitalizations.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Insuficiência Cardíaca , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/complicações , Antiarrítmicos/uso terapêutico , Ensaios Clínicos Controlados Aleatórios como Assunto , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Ablação por Cateter/métodos , Resultado do Tratamento
4.
Europace ; 25(3): 1077-1086, 2023 03 30.
Artigo em Inglês | MEDLINE | ID: mdl-36352513

RESUMO

Guidelines recommend patients undergoing a first pacemaker implant who have even mild left ventricular (LV) impairment should receive biventricular or conduction system pacing (CSP). There is no corresponding recommendation for patients who already have a pacemaker. We conducted a meta-analysis of randomized controlled trials (RCTs) and observational studies assessing device upgrades. The primary outcome was the echocardiographic change in LV ejection fraction (LVEF). Six RCTs (randomizing 161 patients) and 47 observational studies (2644 patients) assessing the efficacy of upgrade to biventricular pacing were eligible for analysis. Eight observational studies recruiting 217 patients of CSP upgrade were also eligible. Fourteen additional studies contributed data on complications (25 412 patients). Randomized controlled trials of biventricular pacing upgrade showed LVEF improvement of +8.4% from 35.5% and observational studies: +8.4% from 25.7%. Observational studies of left bundle branch area pacing upgrade showed +11.1% improvement from 39.0% and observational studies of His bundle pacing upgrade showed +12.7% improvement from 36.0%. New York Heart Association class decreased by -0.4, -0.8, -1.0, and -1.2, respectively. Randomized controlled trials of biventricular upgrade found improvement in Minnesota Heart Failure Score (-6.9 points) and peak oxygen uptake (+1.1 mL/kg/min). This was also seen in observational studies of biventricular upgrades (-19.67 points and +2.63 mL/kg/min, respectively). In studies of the biventricular upgrade, complication rates averaged 2% for pneumothorax, 1.4% for tamponade, and 3.7% for infection over 24 months of mean follow-up. Lead-related complications occurred in 3.3% of biventricular upgrades and 1.8% of CSP upgrades. Randomized controlled trials show significant physiological and symptomatic benefits of upgrading pacemakers to biventricular pacing. Observational studies show similar effects between biventricular pacing upgrade and CSP upgrade.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Marca-Passo Artificial , Disfunção Ventricular Esquerda , Humanos , Terapia de Ressincronização Cardíaca/efeitos adversos , Estimulação Cardíaca Artificial/efeitos adversos , Doença do Sistema de Condução Cardíaco/terapia , Sistema de Condução Cardíaco , Função Ventricular Esquerda , Volume Sistólico/fisiologia , Resultado do Tratamento , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia
5.
Europace ; 25(5)2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-36916199

RESUMO

AIMS: The field of conduction system pacing (CSP) is evolving, and our aim was to obtain a contemporary picture of European CSP practice. METHODS AND RESULTS: A survey was devised by a European CSP Expert Group and sent electronically to cardiologists utilizing CSP. A total of 284 physicians were invited to contribute of which 171 physicians (60.2%; 85% electrophysiologists) responded. Most (77%) had experience with both His-bundle pacing (HBP) and left bundle branch area pacing (LBBAP). Pacing indications ranked highest for CSP were atrioventricular block (irrespective of left ventricular ejection fraction) and when coronary sinus lead implantation failed. For patients with left bundle branch block (LBBB) and heart failure (HF), conventional biventricular pacing remained first-line treatment. For most indications, operators preferred LBBAP over HBP as a first-line approach. When HBP was attempted as an initial approach, reasons reported for transitioning to utilizing LBBAP were: (i) high threshold (reported as >2 V at 1 ms), (ii) failure to reverse bundle branch block, or (iii) > 30 min attempting to implant at His-bundle sites. Backup right ventricular lead use for HBP was low (median 20%) and predominated in pace-and-ablate scenarios. Twelve-lead electrocardiogram assessment was deemed highly important during follow-up. This, coupled with limitations from current capture management algorithms, limits remote monitoring for CSP patients. CONCLUSIONS: This survey provides a snapshot of CSP implementation in Europe. Currently, CSP is predominantly used for bradycardia indications. For HF patients with LBBB, most operators reserve CSP for biventricular implant failures. Left bundle branch area pacing ostensibly has practical advantages over HBP and is therefore preferred by many operators. Practical limitations remain, and large randomized clinical trial data are currently lacking.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Volume Sistólico/fisiologia , Função Ventricular Esquerda , Resultado do Tratamento , Sistema de Condução Cardíaco , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/terapia , Arritmias Cardíacas/terapia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia
6.
Europace ; 25(10)2023 10 05.
Artigo em Inglês | MEDLINE | ID: mdl-37815462

RESUMO

AIMS: Left bundle branch pacing (LBBP) can deliver physiological left ventricular activation, but typically at the cost of delayed right ventricular (RV) activation. Right ventricular activation can be advanced through anodal capture, but there is uncertainty regarding the mechanism by which this is achieved, and it is not known whether this produces haemodynamic benefit. METHODS AND RESULTS: We recruited patients with LBBP leads in whom anodal capture eliminated the terminal R-wave in lead V1. Ventricular activation pattern, timing, and high-precision acute haemodynamic response were studied during LBBP with and without anodal capture. We recruited 21 patients with a mean age of 67 years, of whom 14 were males. We measured electrocardiogram timings and haemodynamics in all patients, and in 16, we also performed non-invasive mapping. Ventricular epicardial propagation maps demonstrated that RV septal myocardial capture, rather than right bundle capture, was the mechanism for earlier RV activation. With anodal capture, QRS duration and total ventricular activation times were shorter (116 ± 12 vs. 129 ± 14 ms, P < 0.01 and 83 ± 18 vs. 90 ± 15 ms, P = 0.01). This required higher outputs (3.6 ± 1.9 vs. 0.6 ± 0.2 V, P < 0.01) but without additional haemodynamic benefit (mean difference -0.2 ± 3.8 mmHg compared with pacing without anodal capture, P = 0.2). CONCLUSION: Left bundle branch pacing with anodal capture advances RV activation by stimulating the RV septal myocardium. However, this requires higher outputs and does not improve acute haemodynamics. Aiming for anodal capture may therefore not be necessary.


Assuntos
Fascículo Atrioventricular , Estimulação Cardíaca Artificial , Masculino , Humanos , Idoso , Feminino , Estimulação Cardíaca Artificial/métodos , Sistema de Condução Cardíaco , Hemodinâmica , Ventrículos do Coração , Eletrocardiografia/métodos
7.
Pacing Clin Electrophysiol ; 46(9): 1077-1084, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37594233

RESUMO

BACKGROUND: The use of left bundle branch area pacing (LBBAP) for bradycardia pacing and cardiac resynchronization is increasing, but implants are not always successful. We prospectively studied consecutive patients to determine whether septal scar contributes to implant failure. METHODS: Patients scheduled for bradycardia pacing or cardiac resynchronization therapy were prospectively enrolled. Recruited patients underwent preprocedural scar assessment by cardiac MRI with late gadolinium enhancement imaging. LBBAP was attempted using a lumenless lead (Medtronic 3830) via a transeptal approach. RESULTS: Thirty-five patients were recruited: 29 male, mean age 68 years, 10 ischemic, and 16 non-ischemic cardiomyopathy. Pacing indication was bradycardia in 26% and cardiac resynchronization in 74%. The lead was successfully deployed to the left ventricular septum in 30/35 (86%) and unsuccessful in the remaining 5/35 (14%). Septal late gadolinium enhancement was significantly less extensive in patients where left septal lead deployment was successful, compared those where it was unsuccessful (median 8%, IQR 2%-18% vs. median 54%, IQR 53%-57%, p < .001). CONCLUSIONS: The presence of septal scar appears to make it more challenging to deploy a lead to the left ventricular septum via the transeptal route. Additional implant tools or alternative approaches may be required in patients with extensive septal scar.


Assuntos
Septo Interventricular , Humanos , Masculino , Idoso , Septo Interventricular/diagnóstico por imagem , Bradicardia , Cicatriz , Meios de Contraste , Gadolínio
8.
Eur Heart J Suppl ; 25(Suppl G): G27-G32, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37970515

RESUMO

Patients with heart failure who have a prolonged PR interval are at a greater risk of adverse clinical outcomes than those with a normal PR interval. Potential mechanisms of harm relating to prolonged PR intervals include reduced ventricular filling and also the potential progression to a higher degree heart block. There has, however, been relatively little work specifically focusing on isolated PR prolongation as a therapeutic target. Secondary analyses of trials of biventricular pacing in heart failure have suggested that PR prolongation is both a prognostic marker and a promising treatment target. However, while biventricular pacing offers an improved activation pattern, it is nonetheless less physiological than native conduction in patients with a narrow QRS duration, and thus, may not be the ideal option for achieving therapeutic shortening of atrioventricular delay. Conduction system pacing aims to preserve physiological ventricular activation and may therefore be the ideal method for ventricular pacing in patients with isolated PR prolongation. Acute haemodynamic experiments and the recently reported His-optimized pacing evaluated for heart failure (HOPE HF) Randomised Controlled Trial demonstrates the potential benefits of physiological ventricular pacing on patient symptoms and left ventricular function in patients with heart failure.

9.
Eur Heart J Suppl ; 25(Suppl G): G15-G26, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37970519

RESUMO

His bundle pacing and left bundle branch pacing, together referred to as conduction system pacing, have (re)gained considerable interest over the past years as it has the potential to preserve and/or restore a more physiological ventricular activation when compared with right ventricular pacing and may serve as an alternative for cardiac resynchronization therapy. This review manuscript dives deeper into the implantation techniques and the relevant anatomy of the conduction system for both pacing strategies. Furthermore, the manuscript elaborates on better understanding of conduction system capture with its various capture patterns, its potential complications as well as appropriate follow-up care. Finally, the limitations and its impact on clinical care for both His bundle pacing and left bundle branch pacing are being discussed.

10.
Pacing Clin Electrophysiol ; 45(4): 461-470, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34967945

RESUMO

BACKGROUND: Hemodynamically optimal atrioventricular (AV) delay can be derived by echocardiography or beat-by-beat blood pressure (BP) measurements, but analysis is labor intensive. Laser Doppler perfusion monitoring measures blood flow and can be incorporated into future implantable cardiac devices. We assess whether laser Doppler can be used instead of BP to optimize AV delay. METHODS: Fifty eight patients underwent 94 AV delay optimizations with biventricular or His-bundle pacing using laser Doppler and simultaneous noninvasive beat-by-beat BP. Optimal AV delay was defined using a curve of hemodynamic response to switching from AAI (reference state) to DDD (test state) at several AV delays (40-320 ms), with automatic quality control checking precision of the optimum. Five subsequent patients underwent an extended protocol to test the impact of greater numbers of alternations on optimization quality. RESULTS: 55/94 optimizations passed quality control resulting in an optimal AV delay on laser Doppler similar to that derived by BP (median absolute deviation 12 ms). An extended protocol with increasing number of replicates consistently improved quality and reduced disagreement between laser Doppler and BP optima. With only five replicates, no optimization passed quality control, and the median absolute deviation would be 29 ms. These improved progressively until at 50 replicates, all optimizations passed quality control and the median absolute deviation was only 13 ms. CONCLUSIONS: Laser Doppler perfusion produces hemodynamic optima equivalent to BP. Quality control can be automatic. Adding more replicates, consistently improves quality. Future implantable devices could use such methods to dynamically and reliably optimize AV delays.


Assuntos
Nó Atrioventricular , Marca-Passo Artificial , Biomarcadores , Estimulação Cardíaca Artificial/métodos , Ventrículos do Coração , Hemodinâmica , Humanos
11.
J Cardiovasc Electrophysiol ; 32(2): 428-438, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33345379

RESUMO

BACKGROUND: His bundle pacing (HBP) is an alternative to biventricular pacing (BVP) for delivering cardiac resynchronization therapy (CRT) in patients with heart failure and left bundle branch block (LBBB). It is not known whether ventricular activation times and patterns achieved by HBP are equivalent to intact conduction systems and not all patients with LBBB are resynchronized by HBP. OBJECTIVE: To compare activation times and patterns of His-CRT with BVP-CRT, LBBB and intact conduction systems. METHODS: In patients with LBBB, noninvasive epicardial mapping (ECG imaging) was performed during BVP and temporary HBP. Intrinsic activation was mapped in all subjects. Left ventricular activation times (LVAT) were measured and epicardial propagation mapping (EPM) was performed, to visualize epicardial wavefronts. Normal activation pattern and a normal LVAT range were determined from normal subjects. RESULTS: Forty-five patients were included, 24 with LBBB and LV impairment, and 21 with normal 12-lead ECG and LV function. In 87.5% of patients with LBBB, His-CRT successfully shortened LVAT by ≥10 ms. In 33.3%, His-CRT resulted in complete ventricular resynchronization, with activation times and patterns indistinguishable from normal subjects. EPM identified propagation discontinuity artifacts in 83% of patients with LBBB. This was the best predictor of whether successful resynchronization was achieved by HBP (logarithmic odds ratio, 2.19; 95% confidence interval, 0.07-4.31; p = .04). CONCLUSION: Noninvasive electrocardiographic mapping appears to identify patients whose LBBB can be resynchronized by HBP. In contrast to BVP, His-CRT may deliver the maximum potential ventricular resynchronization, returning activation times, and patterns to those seen in normal hearts.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Fascículo Atrioventricular , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/terapia , Eletrocardiografia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Humanos , Resultado do Tratamento , Função Ventricular Esquerda
12.
J Cardiovasc Electrophysiol ; 31(11): 2964-2974, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32976636

RESUMO

AIMS: A prolonged PR interval may adversely affect ventricular filling and, therefore, cardiac function. AV delay can be corrected using right ventricular pacing (RVP), but this induces ventricular dyssynchrony, itself harmful. Therefore, in intermittent heart block, pacing avoidance algorithms are often implemented. We tested His-bundle pacing (HBP) as an alternative. METHODS: Outpatients with a long PR interval (>200 ms) and intermittent need for ventricular pacing were recruited. We measured within-patient differences in high-precision hemodynamics between AV-optimized RVP and HBP, as well as a pacing avoidance algorithm (Managed Ventricular Pacing [MVP]). RESULTS: We recruited 18 patients. Mean left ventricular ejection fraction was 44.3 ± 9%. Mean intrinsic PR interval was 266 ± 42 ms and QRS duration was 123 ± 29 ms. RVP lengthened QRS duration (+54 ms, 95% CI 42-67 ms, p < .0001) while HBP delivered a shorter QRS duration than RVP (-56 ms, 95% CI -67 to -46 ms, p < .0001). HBP did not increase QRS duration (-2 ms, 95% CI -8 to 13 ms, p = .6). HBP improved acute systolic blood pressure by mean of 5.0 mmHg (95% CI 2.8-7.1 mmHg, p < .0001) compared to RVP and by 3.5 mmHg (95% CI 1.9-5.0 mmHg, p = .0002) compared to the pacing avoidance algorithm. There was no significant difference in hemodynamics between RVP and ventricular pacing avoidance (p = .055). CONCLUSIONS: HBP provides better acute cardiac function than pacing avoidance algorithms and RVP, in patients with prolonged PR intervals. HBP allows normalization of prolonged AV delays (unlike pacing avoidance) and does not cause ventricular dyssynchrony (unlike RVP). Clinical trials may be justified to assess whether these acute improvements translate into longer term clinical benefits in patients with bradycardia indications for pacing.


Assuntos
Fascículo Atrioventricular , Estimulação Cardíaca Artificial , Algoritmos , Hemodinâmica , Humanos , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
13.
J Cardiovasc Electrophysiol ; 30(9): 1610-1619, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31115945

RESUMO

INTRODUCTION: New pacing technologies offer a greater choice of left ventricular pacing sites and greater personalization of cardiac resynchronization therapy (CRT). The effects on cardiac function of novel pacing configurations are often compared using multi-beat averages of acute hemodynamic measurements. In this analysis of the iSpot trial, we explore whether this is sufficient. MATERIALS AND METHODS: The iSpot trial was an international, prospective, acute hemodynamic trial that assessed seven CRT configurations: standard CRT, MultiSpot (posterolateral vein), and MultiVein (anterior and posterior vein) pacing. Invasive and noninvasive blood pressure, and left ventricular (LV) dP/dtmax were recorded. Eight beats were recorded before and after an alternation from AAI to the tested pacing configuration and vice-versa. Eight alternations were performed for each configuration at each of the five atrioventricular delays. RESULTS: Twenty-five patients underwent the full protocol of eight alternations. Only four (16%) patients had a statistically significant >3 mm Hg improvement over conventional CRT configuration (posterolateral vein, distal electrode). However, if only one alternation was analyzed (standard multi-beat averaging protocol), 15 (60%) patients falsely appeared to have a superior nonconventional configuration. Responses to pacing were significantly correlated between the different hemodynamic measures: invasive systolic blood pressure (SBP) vs noninvasive SBP r = 0.82 (P < .001); invasive SBP vs LV dP/dt r = 0.57, r2 = 0.32 (P < .001). CONCLUSIONS: Current standard multibeat acquisition protocols are unfortunately unable to prevent false impressions of optimality arising in individual patients. Personalization processes need to include distinct repeated transitions to the tested pacing configuration in addition to averaging multiple beats. The need is not only during research stages but also during clinical implementation.


Assuntos
Bloqueio de Ramo/terapia , Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca/terapia , Monitorização Hemodinâmica , Hemodinâmica , Pressão Sanguínea , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/fisiopatologia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Frequência Cardíaca , Humanos , Valor Preditivo dos Testes , Estudos Prospectivos , Fatores de Tempo , Resultado do Tratamento , Função Ventricular Esquerda , Pressão Ventricular
14.
J Cardiovasc Electrophysiol ; 30(10): 1984-1993, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31310403

RESUMO

BACKGROUND: His-bundle pacing (HBP) provides physiological ventricular activation. Observational studies have demonstrated the techniques' feasibility; however, data have come from a limited number of centers. OBJECTIVES: We set out to explore the contemporary global practice in HBP focusing on the learning curve, procedural characteristics, and outcomes. METHODS: This is a retrospective, multicenter observational study of patients undergoing attempted HBP at seven centers. Pacing indication, fluoroscopy time, HBP thresholds, and lead reintervention and deactivation rates were recorded. Where centers had systematically recorded implant success rates from the outset, these were collated. RESULTS: A total of 529 patients underwent attempted HBP during the study period (2014-19) with a mean follow-up of 217 ± 303 days. Most implants were for bradycardia indications. In the three centers with the systematic collation of all attempts, the overall implant success rate was 81%, which improved to 87% after completion of 40 cases. All seven centers reported data on successful implants. The mean fluoroscopy time was 11.7 ± 12.0 minutes, the His-bundle capture threshold at implant was 1.4 ± 0.9 V at 0.8 ± 0.3 ms, and it was 1.3 ± 1.2 V at 0.9 ± 0.2 ms at last device check. HBP lead reintervention or deactivation (for lead displacement or rise in threshold) occurred in 7.5% of successful implants. There was evidence of a learning curve: fluoroscopy time and HBP capture threshold reduced with greater experience, plateauing after approximately 30-50 cases. CONCLUSION: We found that it is feasible to establish a successful HBP program, using the currently available implantation tools. For physicians who are experienced at pacemaker implantation, the steepest part of the learning curve appears to be over the first 30-50 cases.


Assuntos
Arritmias Cardíacas/terapia , Fascículo Atrioventricular/fisiopatologia , Estimulação Cardíaca Artificial , Curva de Aprendizado , Potenciais de Ação , Idoso , Idoso de 80 Anos ou mais , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Estimulação Cardíaca Artificial/efeitos adversos , Competência Clínica , Europa (Continente) , Estudos de Viabilidade , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Segurança do Paciente , Ensaios Clínicos Controlados Aleatórios como Assunto , Sistema de Registros , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
15.
J Pediatr Hematol Oncol ; 40(3): e159-e163, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29432312

RESUMO

Medulloblastoma is the most common malignant brain tumor in children. Published survival rates for this tumor are ∼70%; however, there is limited published information on outcome after disease recurrence. This was an observational study which included all persons under the age of 18 years diagnosed with medulloblastoma from 1990 to 2009 inclusive in Canada. Data collected included date of diagnosis, age at diagnosis, sex, stage, pathology, treatment, recurrence, and current status. Survival rates were determined. In total, 550 cases were ascertained meeting the study criteria. The overall survival rate at 1 year was 83.6%±1.7%, at 3 years 77.2%±1.9%, and at 5 years 72.5%±20%. The progression-free survival rates were 78%±1.9%, 70%±2.1%, and 69±2.1% at 1, 3, and 5 years from initial diagnosis. In total, 173 (31.2%) were reported to have had tumor recurrence and 23 (11.4%) of them were alive at the time of survey with an overall survival rate at 1 year of 38.3%±4%, at 2 years of 16.9%±3.3%, and at 5 years of 12.4%±2.8%. Our data confirm that children with recurrent medulloblastoma have a poor prognosis, supporting the need for novel treatment approaches for this group.


Assuntos
Neoplasias Cerebelares/mortalidade , Meduloblastoma/mortalidade , Recidiva Local de Neoplasia/mortalidade , Adolescente , Canadá/epidemiologia , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Masculino
17.
Transfusion ; 55 Suppl 2: S23-7, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26174894

RESUMO

BACKGROUND: Hemolysis is a rare adverse event associated with the use of intravenous immune globulin (IVIG). Using the Canadian experience, this article compares two methods used for case ascertainment of hemolysis after IVIG. STUDY DESIGN AND METHODS: This is a retrospective, descriptive analysis of case reports of hemolytic reaction after exposure to IVIG. The cases were ascertained from the Canada Vigilance database using the standardized MedDRA query for hemolytic disorders between the years 2006 and 2012 inclusively. The presence of a causal relationship was determined by using the Transfusion Transmitted Injuries Surveillance System (TTISS) algorithm. Cases were then reviewed against the standardized case definition of IVIG-associated hemolysis proposed by the IVIG Hemolysis Pharmacovigilance Group. RESULTS: A total of 942 adverse event reports after exposure to IVIG had been received by Canada Vigilance during the study period. A search for the adverse event of hemolytic disorder retrieved 313 reports (33%). Using a modified TTISS definition of hemolysis and the TTISS causality assessment algorithm, 226 cases were found to be at least possibly related to administration of IVIG, whereas 69 cases met the definition of the IVIG Hemolysis Pharmacovigilance Group. The amount of IVIG distributed increased over the study period; this trend was not reflected in the number of adverse reaction reports for "hemolytic disorder" received. CONCLUSION: The number of case reports per year received for the adverse event "hemolytic disorder" after exposure to IVIG fluctuated. The number of confirmed case reports varied depending on the case definition being used.


Assuntos
Algoritmos , Bases de Dados Factuais , Hemólise/efeitos dos fármacos , Imunoglobulinas Intravenosas/efeitos adversos , Fatores Imunológicos/efeitos adversos , Farmacovigilância , Canadá/epidemiologia , Estudos de Casos e Controles , Feminino , Humanos , Imunoglobulinas Intravenosas/administração & dosagem , Fatores Imunológicos/administração & dosagem , Masculino
18.
J Neurooncol ; 124(2): 247-53, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26024655

RESUMO

The treatment of medulloblastoma, the most common malignant brain tumor in children, has evolved over the last few decades. The objectives of this paper were to determine the survival of pediatric medulloblastoma in Canada, to determine if there has been an improvement in the survival rates between the years of 1990 and 2009, inclusive, and to determine prognostic factors for survival. All patients under the age of 18 years diagnosed with medulloblastoma from 1990 to 2009, inclusive, in Canada were included. Data collected included date of diagnosis, age at diagnosis, gender, stage, pathology, treatment, recurrence and current status. From these, survival rates were determined. Data were obtained on 628 eligible patients. The overall 5-year survival rate for the study time period was 69.2 ± 3.3 %. The survival rate increased during the interval of 1996-2000, then remained stable; 1990-1994: 60.2 ± 4.3 %; 1995-1999: 73.2 ± 3.5 %; 2000-2004: 68.8 ± 3.7 %; and 2005-2009: 72.1 ± 4.9 %, p = 0.05. Children over 14 years of age had a significantly better overall survival than those age 5-14 and those under 5 (85.7 ± 5.5 % vs 76.1 ± 2.7 % and 60.8 ± 3 % respectively, p = 0.001). Histologic medulloblastoma subtype and M stage of disease did not result in significant differences in survival. Despite changes in approaches to therapy, we demonstrate a steady survival rate for children with medulloblastoma after 1996. In our analyses, age over 14 years was associated with a higher survival rate.


Assuntos
Neoplasias Encefálicas/mortalidade , Meduloblastoma/mortalidade , Adolescente , Fatores Etários , Neoplasias Encefálicas/terapia , Canadá/epidemiologia , Criança , Pré-Escolar , Feminino , Humanos , Masculino , Meduloblastoma/terapia , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Análise de Sobrevida
19.
J Neurooncol ; 124(1): 95-100, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25968346

RESUMO

In children under the age of 3 years, the most common solid tumors are brain tumors. Low grade astrocytomas represent 30-40 % of brain tumours in this age group. This study reviewed the incidence, characteristics, therapy, and outcome of children less than 36 months of age diagnosed with a low grade astrocytoma from 1990 to 2005 in Canada. A data bank was established using data collected from Canadian pediatric oncology centers on children less than age 3 diagnosed with brain tumors between 1990 and 2005. Cases of low grade astrocytoma were extracted from this data bank and their characteristics summarized. From the 579 cases in the data bank, 153 cases of low grade astrocytoma (26 %) were identified. The mean duration of symptoms prior to presentation was 13 weeks, and 53 % of patients underwent a greater than 90 % resection of their tumor, while 30 % underwent 10-90 % resection. Seventy-one percent of patients received no further therapy after surgery and of the 45 who received therapy following surgery, 43 received chemotherapy, and 5 received radiation therapy. Sixty-eight patients had recurrence or progression of their tumor. Eighty-seven percent of patients were alive at the time of the survey with a 2 year survival rate of 95.3 ± 1.8 %, 5 year survival rate of 93.1 ± 2.1 % and 10 year survival rate of 89.1 ± 2.8 %. The 5 year survival rate for Canadian children less than 36 months of age with a low grade astrocytoma was 93.0 ± 2.8 % which is similar to that for older children with this tumor.


Assuntos
Astrocitoma/epidemiologia , Neoplasias Encefálicas/epidemiologia , Canadá/epidemiologia , Pré-Escolar , Progressão da Doença , Feminino , Humanos , Lactente , Recém-Nascido , Estimativa de Kaplan-Meier , Masculino
20.
J Neurooncol ; 117(2): 359-64, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24532240

RESUMO

The determination of optimal therapy for ependymoma (EP) in infants is ongoing. We describe the incidence, management and outcomes of Canadian infants with EP to discern potential future research questions. Of 579 cases registered in a national database of children <36 months of age diagnosed with a brain tumor from 1990 to 2005, inclusive, 75 (13 %) were EP. These cases were analyzed. A mean annual age-adjusted incidence rate of 4.6 per 100,000 children years was calculated. The male:female ratio was 1.77. Of the tumors, 80 % were infratentorial in location, 67 % were WHO grade II histology, and 29 % were metastatic at diagnosis. All patients underwent a surgical procedure. A complete resection of the tumor was achieved in 56 % of the cases; 43 % of these patients survive while 36 % of the patients with tumors less than completely resected survive. Initial therapy consisted of surgery alone in 23 % of patients, or surgery plus chemotherapy (37 %), radiation therapy (RT; 19 %), or both (21 %). Any use of RT increased with patient age. The 5-year EFS rates for patients in each of the four treatment groups was 22, 11.5, 46.2 and 64.8 %, respectively. For all patients the median survival was 63 ± 6 months and 5-year overall survival was 55 ± 6 %. Patients treated with surgery and chemotherapy alone were younger and had a lower rate of survival than older patients who were more often treated with radiation therapy containing regimens. Further study is needed to determine which patients are optimally served with these treatment modalities.


Assuntos
Neoplasias Encefálicas/epidemiologia , Ependimoma/epidemiologia , Neoplasias Encefálicas/patologia , Neoplasias Encefálicas/terapia , Canadá/epidemiologia , Pré-Escolar , Bases de Dados Factuais , Ependimoma/patologia , Ependimoma/terapia , Feminino , Humanos , Incidência , Lactente , Recém-Nascido , Masculino , Pediatria/estatística & dados numéricos
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa