Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Strength Cond Res ; 37(10): 1929-1938, 2023 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-37729510

RESUMO

ABSTRACT: Nagatani, T, Kendall, KL, Guppy, SN, Poon, WCK, and Haff, GG. Effect of 3 different set configurations on kinematic variables and internal loads during a power snatch session. J Strength Cond Res 37(10): 1929-1938, 2023-The aim of this study was to investigate the effect of 3 different set configurations on kinematic variables and internal loads during multiple sets performed with the power snatch. Ten strength-power athletes with at least 6 months of training experience performing the power snatch participated in this study, which consisted of 3 experimental protocols performed in a randomized repeated-measures design. The 3 protocols involved performing the power snatch for 3 sets of 5 repetitions at an average load of 75% 1 repetition maximum with a traditional (TRAD), cluster (CLU), or ascending cluster (A-CLU) protocol, where the training load was progressively increased across the set. Kinematic variables and internal loads (heart rate, blood lactate, and rate of perceived exertion) were measured during each protocol. The athletes maintained peak velocity (PV) and peak power (PP) and exhibited lower internal loads during CLU sets when compared with TRAD sets, whereas they displayed significant decreases in PV during TRAD sets. However, there were no statistically significant differences in PV and PP responses between the TRAD and CLU protocol. The athletes exhibited a significant decrease in PV, whereas PP was increased across each set in the A-CLU protocol, with lower internal loads observed compared with the TRAD protocol. Overall, the training loads used in this study do not appear to maximize the benefits of using CLU set during 3 sets of power snatches performed for 5 repetitions. In addition, A-CLU sets may potentially be useful as a means of maximizing the power output of the athlete.


Assuntos
Atletas , Humanos , Fenômenos Biomecânicos , Frequência Cardíaca
2.
J Strength Cond Res ; 37(12): 2467-2476, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-38015736

RESUMO

ABSTRACT: Boffey, D, DiPrima, JA, Kendall, KL, Hill, EC, Stout, JR, and Fukuda, DH. Influence of body composition, load-velocity profiles, and sex-related differences on army combat fitness test performance. J Strength Cond Res 37(12): 2467-2476, 2023-The Army Combat Fitness Test (ACFT) became the U.S. Army's mandatory physical fitness test in April of 2022. The purpose of this study was to determine the relationship between ACFT performance and both body composition and velocity profiles and to determine sex differences for these variables. Data were collected at 2 timepoints 4 months apart, from male (n = 55) and female (n = 17) Army Reserve Officers' Training Corps (ROTC) cadets. Body composition was assessed with a bioelectrical impedance spectroscopy device, and cadets completed a hex bar deadlift load-velocity profile (LVP) and ACFT on separate days. Stepwise multiple regressions were used to explain the amount of variance in ACFT total score and individual event performance. Significance for statistical tests was defined as an alpha level of p ≤ 0.05. Muscle mass and body fat percentage accounted for 49% of shared variance of total ACFT score, and deadlift maximal power and maximal velocity accounted for 67% of shared variance of total ACFT score. The 3 repetition maximum deadlift, standing power throw, hand-release push-up, and sprint-drag-carry events favored cadets with more muscle mass, whereas the leg tuck was influenced by the body fat percentage and the 2-mile run was affected by fat mass. Sex had greater predictive capability for the 2-mile run than body composition. Men outperformed women on all individual events, with the greatest differences on standing power throw and sprint-drag-carry. It is recommended that Army ROTC cadets taking the ACFT maximize lower-body power production and increase muscle mass.


Assuntos
Teste de Esforço , Militares , Humanos , Masculino , Feminino , Teste de Esforço/métodos , Caracteres Sexuais , Aptidão Física/fisiologia , Exercício Físico , Composição Corporal
3.
J Strength Cond Res ; 35(6): 1535-1541, 2021 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-34027920

RESUMO

ABSTRACT: Herda, AA, Smith-Ryan, AE, Kendall, KL, Cramer, JT, and Stout, JR. Evaluation of high-intensity interval training and beta-alanine supplementation on efficiency of electrical activity and electromyographic fatigue threshold. J Strength Cond Res 35(6): 1535-1541, 2021-The purpose of this study was to determine the effects of high-intensity interval training (HIIT) with or without ß-alanine (BA) supplementation on the electromyographic fatigue threshold (EMGFT) and efficiency of electrical activity (EEA) in young women. Forty-four women (mean ± SD; age [yrs]: 21.7 ± 3.7; height [cm]: 166.3 ± 6.4; body mass [kg]: 66.1 ± 10.3) were randomly assigned to one of 3 treatment groups. The supplement groups performed HIIT on the cycle ergometer 3 times·wk-1 for 6 weeks. Electromyographic fatigue threshold and EEA were assessed at baseline (PRE), after 3 weeks of training (MID), and after 6 weeks of HIIT (POST). Two 2-way mixed factorial analyses of variance (time [PRE vs. MID vs. POST] × treatment (BA vs. PL vs. CON)] were used to analyze EMGFT and EEA with a predetermined level of significance α of 0.05. For EMGFT, there was no interaction (p = 0.26) and no main effect for time (p = 0.28) nor treatment (p = 0.86); thus, there were no changes in EMGFT regardless of training or supplementation status. For EEA, there was no interaction (p = 0.70) nor treatment (p = 0.79); however, there was a main effect for time (p < 0.01). Our findings indicated that neither training nor supplementation was effective in improving EMGFT in women. Efficiency of electrical activity was altered, potentially because of a learning effect. Coaches and practitioners may not use these tests to monitor training status; however, they may find EEA as a useful tool to track cycling efficiency.


Assuntos
Treinamento Intervalado de Alta Intensidade , Suplementos Nutricionais , Eletromiografia , Teste de Esforço , Fadiga , Feminino , Humanos , Fadiga Muscular , Consumo de Oxigênio , beta-Alanina
4.
J Am Coll Nutr ; 36(1): 16-27, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27710436

RESUMO

OBJECTIVE: The objective of this study was to compare the chronic effects of different whey protein forms on body composition and performance when supplemented with resistance training. METHODS: Resistance-trained men (N = 56, 21.4 ± 0.4 years, 79.5 ± 1.0 kg) participated in an 8-week resistance training regimen (2 upper-body sessions and 2 lower-body sessions per week) and received one of 4 double-blinded treatments: 30 g/serving carbohydrate placebo (PLA) or 30 g/serving protein from either (a) 80% whey protein concentrate (WPC), (b) high-lactoferrin-containing WPC (WPC-L), or (c) extensively hydrolyzed WPC (WPH). All subjects consumed 2 servings of treatment per day; specifically, once immediately before and after training and between meals on nontraining days. Blood collection, one repetition maximum (1RM) testing for bench press and hack squat, and body composition assessment using dual-energy x-ray absorptiometry (DXA) occurred prior to training and 48 hours following the last training session. RESULTS: Total body skeletal muscle mass increased in all groups (p < 0.0125). There were similar between-group increases in upper-body (4%-7%, analysis of covariance [ANCOVA] interaction p = 0.73) and lower-body (24%-35%, ANCOVA interaction p = 0.85) 1RM strength following the intervention. Remarkably, WPH reduced fat mass (-6%), which was significantly different from PLA (+4.4%, p < 0.0125). No time or between-group differences were present for serum markers of health, metabolism, or muscle damage, with the exception of blood urea nitrogen being significantly lower for WPH than WPC (p < 0.05) following the intervention. CONCLUSIONS: WPH may augment fat loss but did not provide any other advantages when used in combination with resistance training. More mechanistic research is needed to examine how WPH affects adipose tissue physiology.


Assuntos
Exercício Físico/fisiologia , Treinamento Resistido , Proteínas do Soro do Leite/administração & dosagem , Tecido Adiposo/efeitos dos fármacos , Tecido Adiposo/fisiologia , Adulto , Composição Corporal/efeitos dos fármacos , Suplementos Nutricionais , Método Duplo-Cego , Humanos , Lactoferrina/administração & dosagem , Masculino , Músculo Esquelético/efeitos dos fármacos , Músculo Esquelético/fisiologia , Hidrolisados de Proteína/administração & dosagem , Adulto Jovem
5.
J Sports Sci ; 35(7): 624-633, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27159216

RESUMO

The purpose of this study was to investigate the accuracy of fat-free mass (FFM) estimates from two-compartment (2C) models including air displacement plethysmography (ADP), ultrasound (US), near-infrared interactance (NIR), and the Jackson and Pollock skinfold equation (SKF) against a criterion four-compartment (4C) model in elite male rowers. METHODS: Twenty-three elite-level male rowers (mean± SD; age 24.6 ± 2.2 years; stature: 191.4 ± 7.2 cm; mass: 87.2 ± 11.2 kg) participated in this investigation. All body composition assessments were performed on the same day in random order, except for hydrostatic weighing (HW), which was measured last. FFM was evaluated using a 4C model, which included total body water from bioimpedance spectroscopy, body volume from HW, and total body bone mineral via dual-energy X-ray absorptiometry. The major findings of the study were that the 2C models evaluated overestimated FFM and should be considered with caution for the assessment of FFM in elite male rowers. Future studies should use multiple-compartment models, with measurement of TBW and bone mineral content, for the estimation of FFM.


Assuntos
Composição Corporal , Compartimentos de Líquidos Corporais/metabolismo , Pesos e Medidas Corporais/métodos , Modelos Biológicos , Esportes , Absorciometria de Fóton , Tecido Adiposo/metabolismo , Adulto , Atletas , Água Corporal , Densidade Óssea , Impedância Elétrica , Humanos , Masculino , Pletismografia , Reprodutibilidade dos Testes , Dobras Cutâneas , Ultrassonografia , Água , Adulto Jovem
6.
J Strength Cond Res ; 31(2): 395-402, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27359205

RESUMO

Hemmings, TJ, Kendall, KL, and Dobson, JL. Identifying dosage effect of light-emitting diode therapy on muscular fatigue in quadriceps. J Strength Cond Res 31(2): 395-402, 2017-The purpose of this study was to compare the effects of various dosages of light-emitting diode therapy (LEDT) on muscle fatigue while performing a single-leg extension to exhaustion. A total of 34 recreationally resistance-trained athletes between the ages of 18 and 26 participated in 4 trials. Each trial included pre-exercise/postexercise blood lactate measurements and 2 sets of 3 maximal voluntary isometric contractions (MVICs), followed by LEDT on 6 points across the superficial quadriceps. Each randomized trial consisted of a placebo, 30, 60, or 120 seconds on each point on the quadriceps. Three minutes after LEDT, the participants performed an eccentric leg extension with 120% of MVIC until fatigue. There was significant increase in the number of repetitions performed between the placebo treatment and 60 seconds (p = 0.023), as well as placebo and 120 seconds (p = 0.004) of irradiation on each point. There were no significant differences in blood lactate levels between any of the 4 trials. In conclusion, LEDT had a positive effect on performance when irradiating 6 points on the superficial quadriceps for 60 and 120 seconds before an eccentric leg extension.


Assuntos
Exercício Físico/fisiologia , Terapia com Luz de Baixa Intensidade/métodos , Fadiga Muscular/fisiologia , Músculo Quadríceps/fisiologia , Adolescente , Adulto , Atletas , Método Duplo-Cego , Feminino , Humanos , Contração Isométrica , Ácido Láctico/sangue , Masculino , Adulto Jovem
7.
J Strength Cond Res ; 30(12): 3525-3530, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27861264

RESUMO

Hyde, PN, Kendall, KL, Fairman, CM, Coker, NA, Yarbrough, ME, and Rossi, SJ. Utilization of B-mode ultrasound as a body fat estimate in collegiate football players. J Strength Cond Res 30(12): 3525-3530, 2016-The purpose of the present study was to validate a 7-site ultrasound imaging protocol to predict the percent body fat (%BF) in a division I football team. Body composition was estimated by ultrasound, 7-site skinfolds, and the 3-compartment-water (3C-W) model of Siri, using bioimpedance spectroscopy to estimate the total body water and air displacement plethysmography (using BODPOD) to determine the body density. Pearson's product-moment correlation analyses were run to determine correlations between ΣUltrasound and the criterion 3C-W, and between the ΣSkinfold and ΣUltrasound. Strong positive correlations were observed between ΣSkinfold and ΣUltrasound (r = 0.984; p < 0.001). Furthermore, a strong positive correlation was observed between ΣUltrasound and %BF from 3C-W (r = 0.878; p < 0.001). Based on the significant correlation analysis, a linear regression equation was developed to predict the %BF from ΣUltrasound, using %BF from the 3C-W model as the dependent variable: %BF = 6.194 + (0.096 × ΣUltrasound); standard error of the estimate (SEE) = 2.97%. Cross-validation analyses were performed using an independent sample of 29 players. The mean observed %BF from the 3C-W model and the mean predicted %BF were 18.32 ± 6.26% and 18.78 ± 6.22%, respectively. The constant error, SEE, and validity coefficient (r) were 0.87%, 2.64%, and 0.91%, respectively. The total error was 2.87%. The positive relationship between ultrasound measurements and the 3C-W model suggests that ultrasound imaging may be a practical alternative to predicting %BF in division I football players.


Assuntos
Atletas , Composição Corporal , Dobras Cutâneas , Gordura Subcutânea/diagnóstico por imagem , Água Corporal , Estudos Transversais , Futebol Americano , Humanos , Masculino , Pletismografia de Impedância , Reprodutibilidade dos Testes , Ultrassonografia , Adulto Jovem
9.
Artigo em Inglês | MEDLINE | ID: mdl-39197174

RESUMO

This study aimed to determine the energy requirements, physiological consequences, and recovery rate from the Australian Special Forces Selection Course. Ninety-three male soldiers (mean ± SD, 28.1 ± 3.6 y, 1.81 ± 0.1 m, 85.1 ± 8.1 kg) volunteered for this study. Body composition via dual-energy x-ray absorptiometry, hormones and resting metabolic rate were assessed before, immediately after, and at one, three, five, and eight weeks post-course. Energy expenditure, assessed via doubly-labelled water during the first 10 days of the course significantly exceeded energy intake (expenditure: 7680 ± 1095 kcal.d-1, intake: 3859 ± 704 kcal.d-1). Body mass (△ -6.8 ± 1.9 kg, p<0.01), fat mass (△ -4.2 ± 1.0 kg, p<0.0001) and lean mass (△ -3.0 ± 1.7 kg, p<0.0001) were significantly reduced in response to the course and returned to baseline 1-3 weeks post-course. Total testosterone, free testosterone, free triiodothyronine, free thyroxine and insulin like growth factor-1 significantly (p<0.001) declined following the course, while cortisol and sex hormone binding globulin increased (p<0.001). All hormones, except insulin like growth factor-1, returned to baseline concentrations within 1-3 weeks post-course. Resting metabolic rate decreased (p<0.01) in response to the course, and subsequently rebounded above baseline levels at one week post-course. The Special Forces Selection Course involved high energy output and a substantial caloric deficit, resulting in body mass loss and significant hormonal disruption that took weeks to recover. These results highlight the energy requirements, physiological consequences, and recovery processes from the Australian Special Forces Selection Course.

10.
J Sci Med Sport ; 2024 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-39366880

RESUMO

OBJECTIVES: Androgen deprivation therapy (ADT) leads to loss of lean mass (LM) and reduced strength and physical function. Resistance exercise alone can counteract these changes; however, it is unknown if the addition of creatine supplementation can further protect against these ADT-induced toxicities. We compared the effects of creatine supplementation with resistance exercise versus resistance exercise alone in patients with prostate cancer undergoing ADT on LM, muscle strength, and physical function. DESIGN: A 12-week randomized trial. METHODS: Men with prostate cancer receiving ADT (n = 30) were randomized to either resistance exercise + placebo (PLA) or resistance exercise + creatine (SUPP), with both groups undertaking supervised exercise 3 days per week. Outcomes included whole body and appendicular LM and fat mass (FM) assessed by dual-energy X-ray absorptiometry, as well as muscle strength (chest press, seated low, leg press), and physical function (timed up-and-go, chair rise, 400-m walk) assessed at baseline and following the intervention. RESULTS: Patients were aged 59-84 years with a BMI of 28.6 kg·m-2. PLA completed a mean of 30 sessions (83 %) and SUPP a mean of 33 sessions (92 %). Despite similar within-group improvements (p < 0.05) in whole-body LM (PLA +0.6 kg, SUPP +1.3 kg), appendicular LM (PLA +0.5 kg, SUPP +0.6 kg), muscle strength (PLA +8.8-49.3 kg, SUPP +9.4-40.4 kg) and physical function, there were no between group differences (p = 0.078-0.951). No adverse events were reported due to creatine supplementation or resistance exercise. CONCLUSIONS: A short-term program of resistance exercise alone results in meaningful improvements in LM, muscle strength and physical function, with no additional effects of creatine supplementation.

11.
J Strength Cond Res ; 27(2): 331-9, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22476167

RESUMO

The purpose of this study was to characterize the adaptations imposed by 4 weeks of precompetition judo training in youth athletes. It was hypothesized that anthropometric and sport-specific performance would improve during the preparation for a junior national championship event. Twenty youth athletes (mean ± SD; chronological age: 13.1 ± 3.2 years; training age: 5.3 ± 3.5 years; judo experience: 7.8 ± 2.5 hours per week) completed pretesting and posttesting procedures. Child (12 years old; n = 8) and adolescent (13 years old; n = 12) groups were evaluated to determine the anthropometric and sport-specific performance changes caused by 4 weeks of judo training conducted in preparation for the junior national championships. The child group showed an increase in flexibility (11.5%), and the adolescent group showed a decrease in skinfold thickness (-12.2%); increased jumping power (26.7%), force (7.7%), and velocity (19.0%); and improved judo-specific ability (-5.9%), as measured by the Special Judo Fitness Test (SJFT) index. Additionally, the SJFT index for all the study participants was shown to be inversely correlated to handgrip strength (r = -0.681), rope pull performance (r = -0.545), and jump height (r = -0.503). These results support the use of preparatory judo training in the improvement of anthropometric and sport-specific measures in adolescent athletes. Furthermore, the outcomes from this study provide direction for coaches and trainers in their efforts to impact physical performance and judo skills in children and adolescents through precompetition training.


Assuntos
Desempenho Atlético/fisiologia , Exercício Físico/fisiologia , Artes Marciais/fisiologia , Adolescente , Estatura , Peso Corporal , Criança , Feminino , Força da Mão/fisiologia , Humanos , Extremidade Inferior , Masculino , Destreza Motora/fisiologia , Movimento , Força Muscular , Músculo Esquelético/fisiologia , Amplitude de Movimento Articular , Dobras Cutâneas
12.
Eur J Appl Physiol ; 112(4): 1197-205, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21769732

RESUMO

The purpose of this study was to examine the reliability of the intermittent critical velocity (ICV) test and assess critical rest interval (CRI) during repeated-sprint exercise. The ICV test is used to examine the linear relationship between total distance and time-to-exhaustion during interval exercise, yielding a repeatable, moderate-intensity parameter (ICV), a high-intensity exhaustive parameter (W'), and CRI. CRI is the theoretical rest period needed to complete a series of repeated bouts of exercise without fatigue. Twenty-four healthy college-aged men (mean ± SD; age 22.7 ± 2.9 years; weight 85.8 ± 15.3 kg; VO(2max) 50.7 ± 8.8 ml/kg/min) and women (mean ± SD; age 21.4 ± 2.3 years; weight 58.9 ± 5.2 kg; VO(2max) 46.4 ± 4.4 ml/kg/min) participants completed two ICV tests (T1 and T2), using 10 s repeated sprints to exhaustion during separate sessions of treadmill running. Linear regression was used to determine ICV and W', while CRI was calculated using the relationship between the number of intervals completed and a variant of ICV. Intraclass correlation coefficients (ICCs) for ICV, W', and CRI were 0.89 (T1 4.42 ± 0.55 m/s; T2 4.34 ± 0.67 m/s), 0.80 (T1 125.6 ± 62.7 m; T2 144.6 ± 65.4 m), and 0.59 (T1 23.9 ± 2.0 s; T2 24.5 ± 2.6 s), respectively. These moderate to high ICC values indicate reliable measurements between ICV trials. Additionally, the evaluation of CRI demonstrated the attainment of a steady-state heart rate (94% of maximum) during a separate session of repeated supramaximal treadmill sprints. The ICV test during treadmill running provides reliable ICV and W' measures, as well as an estimated recovery time via CRI for men and women.


Assuntos
Teste de Esforço , Exercício Físico , Contração Muscular , Fadiga Muscular , Músculo Esquelético/fisiologia , Corrida , Adulto , Análise de Variância , Feminino , Humanos , Modelos Lineares , Masculino , Oklahoma , Consumo de Oxigênio , Recuperação de Função Fisiológica , Reprodutibilidade dos Testes , Fatores Sexuais , Fatores de Tempo , Estudos de Tempo e Movimento , Adulto Jovem
13.
J Strength Cond Res ; 26(3): 733-8, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22289694

RESUMO

The objective of this study was to examine the relationship between the critical velocity (CV) test and maximal oxygen consumption (VO2max) and develop a regression equation to predict VO2max based on the CV test in female collegiate rowers. Thirty-five female (mean ± SD; age, 19.38 ± 1.3 years; height, 170.27 ± 6.07 cm; body mass, 69.58 ± 0.3 1 kg) collegiate rowers performed 2 incremental VO2max tests to volitional exhaustion on a Concept II Model D rowing ergometer to determine VO2max. After a 72-hour rest period, each rower completed 4 time trials at varying distances for the determination of CV and anaerobic rowing capacity (ARC). A positive correlation was observed between CV and absolute VO2max (r = 0.775, p < 0.001) and ARC and absolute VO2max (r = 0.414, p = 0.040). Based on the significant correlation analysis, a linear regression equation was developed to predict the absolute VO2max from CV and ARC (absolute VO2max = 1.579[CV] + 0.008[ARC] - 3.838; standard error of the estimate [SEE] = 0.192 L·min(-1)). Cross validation analyses were performed using an independent sample of 10 rowers. There was no significant difference between the mean predicted VO2max (3.02 L·min(-1)) and the observed VO2max (3.10 L·min(-1)). The constant error, SEE and validity coefficient (r) were 0.076 L·min(-1), 0.144 L·min(-1), and 0.72, respectively. The total error value was 0.155 L·min(-1). The positive relationship between CV, ARC, and VO2max suggests that the CV test may be a practical alternative to measuring the maximal oxygen uptake in the absence of a metabolic cart. Additional studies are needed to validate the regression equation using a larger sample size and different populations (junior- and senior-level female rowers) and to determine the accuracy of the equation in tracking changes after a training intervention.


Assuntos
Desempenho Atlético/fisiologia , Consumo de Oxigênio/fisiologia , Esportes/fisiologia , Feminino , Humanos , Resistência Física/fisiologia , Adulto Jovem
14.
J Strength Cond Res ; 26(10): 2798-805, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22797003

RESUMO

The use of ß-alanine in sport is widespread. However, the effects across all sport activities are inconclusive. The purpose of this study was to evaluate the effects of ß-alanine supplementation on high-intensity running performance and critical velocity (CV) and anaerobic running capacity (ARC). Fifty recreationally trained men were randomly assigned, in a double-blind fashion, to a ß-alanine group (BA, 2 × 800 mg tablets, 3 times daily; CarnoSyn; n = 26) or placebo group (PL, 2 × 800 mg maltodextrin tablets, 3 times daily; n = 24). A graded exercise test (GXT) was performed to establish peak velocity (PV). Three high-speed runs to exhaustion were performed at 110, 100, and 90% of PV, with 15 minutes of rest between bouts. The distances achieved were plotted over the time to exhaustion (TTE). Linear regression was used to determine the slope (CV) and y-intercept (ARC) of these relationships to assess aerobic and anaerobic performances, respectively. There were no significant treatment effects (p > 0.05) on CV or ARC for either men or women. Additionally, no TTE effects were evident for bouts at 90-110%PV lasting 1.95-5.06 minutes. There seems to be no ergogenic effect of ß-alanine supplementation on CV, ARC, or high-intensity running lasting approximately 2-5 minutes in either men or women in the current study.


Assuntos
Suplementos Nutricionais , Corrida/fisiologia , beta-Alanina/administração & dosagem , Adulto , Limiar Anaeróbio/efeitos dos fármacos , Limiar Anaeróbio/fisiologia , Desempenho Atlético/fisiologia , Método Duplo-Cego , Teste de Esforço , Feminino , Humanos , Masculino , Consumo de Oxigênio/efeitos dos fármacos , Consumo de Oxigênio/fisiologia , Resistência Física/efeitos dos fármacos , Resistência Física/fisiologia , Adulto Jovem
15.
Mil Med ; 177(2): 145-51, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22360058

RESUMO

The purpose of this study was to evaluate the use of critical velocity (CV) and isoperformance curves as an alternative to the Army Physical Fitness Test (APFT) two-mile running test. Seventy-eight men and women (mean +/- SE; age: 22.1 +/- 0.34 years; VO2(MAX): 46.1 +/- 0.82 mL/kg/min) volunteered to participate in this study. A VO2(MAX) test and four treadmill running bouts to exhaustion at varying intensities were completed. The relationship between total distance and time-to-exhaustion was tracked for each exhaustive run to determine CV and anaerobic running capacity. A VO2(MAX) prediction equation (Coefficient of determination: 0.805; Standard error of the estimate: 3.2377 mL/kg/min) was developed using these variables. Isoperformance curves were constructed for men and women to correspond with two-mile run times from APFT standards. Individual CV and anaerobic running capacity values were plotted and compared to isoperformance curves for APFT 2-mile run scores. Fifty-four individuals were determined to receive passing scores from this assessment. Physiological profiles identified from this procedure can be used to assess specific aerobic or anaerobic training needs. With the use of time-to-exhaustion as opposed to a time-trial format used in the two-mile run test, pacing strategies may be limited. The combination of variables from the CV test and isoperformance curves provides an alternative to standardized time-trial testing.


Assuntos
Teste de Esforço/métodos , Consumo de Oxigênio/fisiologia , Aptidão Física/fisiologia , Corrida/fisiologia , Adulto , Exercício Físico/fisiologia , Feminino , Humanos , Modelos Lineares , Masculino , Militares , Resistência Física/fisiologia , Adulto Jovem
16.
Int J Exerc Sci ; 15(1): 632-644, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35989700

RESUMO

Force plates are commonly used when assessing vertical jumping performance but are not always affordable or practical tools for all testing situations. Twenty-four participants volunteered to take part in a study investigating the agreement between bilateral force plates and a new commercially available contact mat that records jump height, flight-time (FT), and FT of individual limbs during both countermovement (CMJ) and squat (SJ) jumps. Each participant performed six jumps of each type while standing on a contact mat placed upon a pair of in-ground force plates. When compared to the force plate via ordinary least products regression, the contact mat agreed with force plate CMJ and SJ jump height, individual limb FT during CMJs, and left-leg FT during SJs. The bilateral contact mat provided valid assessment of individual limb FT during CMJs, but not SJs. Practitioners can therefore use a bilateral contact mat interchangeably with bilateral force plates to measure SJ and CMJ performance.

17.
Eur J Appl Physiol ; 111(4): 679-85, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20963438

RESUMO

The purpose of this study was to propose a systematic method for the identification of training strategies and team selection using isoperformance curves. Rowing is a sport that relies on both aerobic and anaerobic energy contributions during a standard 2,000 m competition. The critical velocity model combines both aerobic (critical velocity, CV) and anaerobic (anaerobic rowing capacity, ARC) parameters in a single two-dimensional graphic display. The concept of isoperformance curves, a series of linear equations corresponding to minimum performance standards, allows for an objective overview of a large group of athletes of varying talent. The purpose of this study was to develop physiological profiles from the CV test, and to evaluate results with isoperformance curves to identify training strategies for collegiate rowers. Thirty-five female collegiate rowers completed four time trials over various distances (400, 600, 800, and 1,000 m). CV and ARC were calculated and compared between novice and varsity athletes. CV values for the varsity group were significantly higher than the novice group (P = 0.016). No significant differences were found between groups for ARC (P = 0.068). Mean and individual CV and ARC values were plotted on the x- and y-axes, respectively, and junior, collegiate, and elite isoperformance curves were developed using 2,000 m times from recent indoor rowing competitions. Stratification of athletes through isoperformance curves was used to identify specific training interventions (anaerobic and/or aerobic) needed to improve their 2,000 m performance. The information drawn from isoperformance curves and the parameters of the CV test can be used to provide an objective view of physiological capabilities and training needs on both an individual and team basis.


Assuntos
Atletas , Desempenho Atlético/fisiologia , Curva de Aprendizado , Educação Física e Treinamento/métodos , Esportes , Adolescente , Feminino , Necessidades e Demandas de Serviços de Saúde , Humanos , Modelos Lineares , Adulto Jovem
18.
J Sports Sci ; 29(9): 945-50, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21574097

RESUMO

The aims of this study were to examine the use of the critical velocity test as a means of predicting 2000-m rowing ergometer performance in female collegiate rowers, and to study the relationship of selected physiological variables on performance times. Thirty-five female collegiate rowers (mean ± s: age 19.3 ± 1.3 years; height 1.70 ± 0.06 m; weight 69.5 ± 7.2 kg) volunteered to participate in the study. Rowers were divided into two categories based on rowing experience: varsity (more than 1 year collegiate experience) and novice (less than 1 year collegiate experience). All rowers performed two continuous graded maximal oxygen consumption tests (familiarization and baseline) to establish maximal oxygen uptake (VO(2max)), peak power output, and power output at ventilatory threshold. Rowers then completed a critical velocity test, consisting of four time-trials at various distances (400 m, 600 m, 800 m, and 1000 m) on two separate days, with 15 min rest between trials. Following the critical velocity test, rowers completed a 2000-m time-trial. Absolute VO(2max) was the strongest predictor of 2000-m performance (r = 0.923) in varsity rowers, with significant correlations also observed for peak power output and critical velocity (r = 0.866 and r = 0.856, respectively). In contrast, critical velocity was the strongest predictor of 2000-m performance in novice rowers (r = 0.733), explaining 54% of the variability in performance. These findings suggest the critical velocity test may be more appropriate for evaluating performance in novice rowers.


Assuntos
Desempenho Atlético/fisiologia , Ergometria/métodos , Consumo de Oxigênio , Esforço Físico/fisiologia , Esportes/fisiologia , Adolescente , Adulto , Teste de Esforço , Feminino , Humanos , Adulto Jovem
19.
J Strength Cond Res ; 25(4): 889-95, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21399529

RESUMO

The intermittent critical velocity (ICV) test is used to quantify the relationship between velocity and time to exhaustion, yielding an aerobic parameter (ICV), an anaerobic parameter (anaerobic running capacity [ARC]), and critical rest interval (CRI). Critical rest interval is the theoretical rest period needed to maintain repeated bouts of exercise for an extended period of time without inducing fatigue during intermittent treadmill running. Fourteen collegiate, club-level male participants (mean ± SD; age: 21.4 ± 1.8 years; weight: 82.8 ± 5.9 kg; body fat: 11.8 ± 5.4%; and VO2max: 51.2 ± 2.8 ml · kg · min), primarily hockey and rugby players, completed the ICV test, using 15-second repeated sprints to exhaustion during separate sessions of treadmill running at varying supramaximal intensities. The time and total distance for each running session were used to determine ICV and ARC via linear regression. The CRI was calculated using the relationship between total distance during the ICV test and the number of intervals completed. Mean ICV and ARC (± SD) values were calculated as 4.80 ± 0.3 m · s and 154.1 ± 36 m, respectively. The mean ICV values were significantly different from the mean peak velocity (± SD) (4.67 ± 0.17 m · s) achieved during the VO2max test (p = 0.011). The CRI was calculated as mean ± SD: 33.9 ± 1.9 seconds. Body fat percentage measured by air displacement plethysmography (BOD POD®; r = -0.649; p = 0.012), lean body mass (r = -0.556; p = 0.039), fat mass (r = -0.634; p = 0.015), body weight (r = -0.669; p = 0.006), and relative VO2max (r = 0.562; p = 0.036) were significantly correlated with ICV. The ARC (r = 0.804; p = 0.001) and velocity at ventilatory threshold (r = -0.630; p = 0.016) were significantly correlated with CRI. The ability to quantify CRI, an additional variable derived from the ICV test, provides a possible measure that can be used in the prescription and evaluation of training methods.


Assuntos
Desempenho Atlético/fisiologia , Futebol Americano/fisiologia , Hóquei/fisiologia , Descanso/fisiologia , Adiposidade/fisiologia , Atletas , Teste de Esforço , Fadiga/fisiopatologia , Humanos , Masculino , Consumo de Oxigênio/fisiologia , Resistência Física/fisiologia , Adulto Jovem
20.
J Strength Cond Res ; 25(3): 652-61, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21273906

RESUMO

Both load cell and mechanical scale-based hydrostatic weighing (HW) systems are used for the measurement of underwater weight. However, there has been no direct comparison of the 2 methods. The purpose of the current investigation was to simultaneously compare a load cell and mechanical scale for use in HW. Twenty-seven men and women (mean ± SD, age: 22 ± 2 years) participated in the 2-day investigation. Each subject completed 2 HW assessments 24 hours apart. Single-day comparisons of all trials for both days revealed no significant difference between the mechanical scale and the load cell (mean difference < 0.016 kg, p > 0.05). True underwater weight values were not significantly different between methods for either days (mean difference < 0.014 kg, p > 0.05) and accounted for a mean difference in percent fat (%FAT) of <0.108%. The 95% limits of agreement indicated a maximum difference between methods of 0.53% FAT. Both methods produced similar reliability SEM values (mechanical SEM < 0.72%FAT, load cell SEM < 0.75%FAT). In conclusion, there was no difference between mechanical scale and load cell measurements of underwater weights and the added precision of the load cell only marginally (<0.16%FAT) improved day-to-day reliability. Either a mechanical scale or load cell can be used for HW with similar accuracy and reliability in young adults with a body mass index of 18.7-34.4 (5-25%FAT).


Assuntos
Composição Corporal/fisiologia , Peso Corporal/fisiologia , Pesos e Medidas Corporais/métodos , Adulto , Feminino , Humanos , Imersão , Masculino , Reprodutibilidade dos Testes , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa