Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Proc Natl Acad Sci U S A ; 118(19)2021 05 11.
Artigo em Inglês | MEDLINE | ID: mdl-33941691

RESUMO

When granular materials, colloidal suspensions, and even animals and crowds exit through a narrow outlet, clogs can form spontaneously when multiple particles or entities attempt to exit simultaneously, thereby obstructing the outlet and ultimately halting the flow. Counterintuitively, the presence of an obstacle upstream of the outlet has been found to suppress clog formation. For soft particles such as emulsion drops, clogging has not been observed in the fast flow limit due to their deformability and vanishing interparticle friction. Instead, they pinch off each other and undergo break up when multiple drops attempt to exit simultaneously. Similar to how an obstacle reduces clogging in a rigid particle system, we hypothesize and demonstrate that an obstacle could suppress break up in the two-dimensional hopper flow of a microfluidic crystal consisting of dense emulsion drops by preventing the simultaneous exit of multiple drops. A regime map plotting the fraction of drops that undergo break up in a channel with different obstacle sizes and locations delineates the geometrical constraints necessary for effective break up suppression. When optimally placed, the obstacle induced an unexpected ordering of the drops, causing them to alternate and exit the outlet one at a time. Droplet break up is suppressed drastically by almost three orders of magnitude compared to when the obstacle is absent. This result can provide a simple, passive strategy to prevent droplet break up and can find use in improving the robustness and integrity of droplet microfluidic biochemical assays as well as in extrusion-based three-dimensional printing of emulsion or foam-based materials.

2.
Anal Chem ; 93(33): 11433-11441, 2021 08 24.
Artigo em Inglês | MEDLINE | ID: mdl-34379402

RESUMO

Aerosols dispersed and transmitted through the air (e.g., particulate matter pollution and bioaerosols) are ubiquitous and one of the leading causes of adverse health effects and disease transmission. A variety of sampling methods (e.g., filters, cyclones, and impactors) have been developed to assess personal exposures. However, a gap still remains in the accessibility and ease-of-use of these technologies for people without experience or training in collecting airborne samples. Additionally, wet scrubbers (large non-portable industrial systems) utilize liquid sprays to remove aerosols from the air; the goal is to "scrub" (i.e., clean) the exhaust of industrial smokestacks, not collect the aerosols for analysis. Inspired by wet scrubbers, we developed a device fundamentally different from existing portable air samplers by using aerosolized microdroplets to capture aerosols in personal spaces (e.g., homes, offices, and schools). Our aerosol-sampling device is the size of a small teapot, can be operated without specialized training, and features a winding flow path in a supersaturated relative humidity environment, enabling droplet growth. The integrated open mesofluidic channels shuttle coalesced droplets to a collection chamber for subsequent sample analysis. Here, we present the experimental demonstration of aerosol capture in water droplets. An iterative study optimized the non-linear flow manipulating baffles and enabled an 83% retention of the aerosolized microdroplets in the confined volume of our device. As a proof-of-concept for aerosol capture into a liquid medium, 0.5-3 µm model particles were used to evaluate aerosol capture efficiency. Finally, we demonstrate that the device can capture and keep a bioaerosol (bacteriophage MS2) viable for downstream analysis.


Assuntos
Levivirus , Material Particulado , Aerossóis/análise , Microbiologia do Ar , Monitoramento Ambiental , Humanos , Tamanho da Partícula
3.
Proc Natl Acad Sci U S A ; 114(28): 7283-7288, 2017 07 11.
Artigo em Inglês | MEDLINE | ID: mdl-28652371

RESUMO

Wound repair is a key feature distinguishing living from nonliving matter. Single cells are increasingly recognized to be capable of healing wounds. The lack of reproducible, high-throughput wounding methods has hindered single-cell wound repair studies. This work describes a microfluidic guillotine for bisecting single Stentor coeruleus cells in a continuous-flow manner. Stentor is used as a model due to its robust repair capacity and the ability to perform gene knockdown in a high-throughput manner. Local cutting dynamics reveals two regimes under which cells are bisected, one at low viscous stress where cells are cut with small membrane ruptures and high viability and one at high viscous stress where cells are cut with extended membrane ruptures and decreased viability. A cutting throughput up to 64 cells per minute-more than 200 times faster than current methods-is achieved. The method allows the generation of more than 100 cells in a synchronized stage of their repair process. This capacity, combined with high-throughput gene knockdown in Stentor, enables time-course mechanistic studies impossible with current wounding methods.


Assuntos
Cilióforos/fisiologia , Técnicas Analíticas Microfluídicas , Microfluídica , Animais , Membrana Celular/metabolismo , Dimetilpolisiloxanos/química , Oócitos/citologia , Pressão , Reprodutibilidade dos Testes , Fatores de Tempo , Viscosidade , Cicatrização , Xenopus
4.
Soft Matter ; 15(6): 1361-1372, 2019 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-30570628

RESUMO

In soft matter consisting of many deformable objects, object shapes often carry important information about local forces and their interactions with the local environment, and can be tightly coupled to the bulk properties and functions. In a concentrated emulsion, for example, the shapes of individual droplets are directly related to the local stress arising from interactions with neighboring drops, which in turn determine their stability and the resulting rheological properties. Shape descriptors used in prior work on single drops and dilute emulsions, where droplet-droplet interactions are largely negligible and the drop shapes are simple, are insufficient to fully capture the broad range of droplet shapes in a concentrated system. This paper describes the application of a machine learning method, specifically a convolutional autoencoder model, that learns to: (1) discover a low-dimensional code (8-dimensional) to describe droplet shapes within a concentrated emulsion, and (2) predict whether the drop will become unstable and undergo break-up. The input consists of images (N = 500 002) of two-dimensional droplet boundaries extracted from movies of a concentrated emulsion flowing through a confined microfluidic channel as a monolayer. The model is able to faithfully reconstruct droplet shapes, as well as to achieve a classification accuracy of 91.7% in the prediction of droplet break-up, compared with ∼60% using conventional scalar descriptors based on droplet elongation. It is observed that 4 out of the 8 dimensions of the code are interpretable, corresponding to drop skewness, elongation, throat size, and surface curvature, respectively. Furthermore, the results show that drop elongation, throat size, and surface curvature are dominant factors in predicting droplet break-up for the flow conditions tested. The method presented is expected to facilitate follow-on work to identify the relationship between drop shapes and the interactions with other drops, and to identify potentially new modes of break-up mechanisms in a concentrated system. Finally, the method developed here should also apply to other soft materials such as foams, gels, and cells and tissues.

5.
Electrophoresis ; 37(4): 658-65, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26613811

RESUMO

Rapid electrokinetic patterning (REP) is an emerging optoelectric technique that takes advantage of laser-induced AC electrothermal flow and particle-electrode interactions to trap and translate particles. The electrothermal flow in REP is driven by the temperature rise induced by the laser absorption in the thin electrode layer. In previous REP applications 350-700 nm indium tin oxide (ITO) layers have been used as electrodes. In this study, we show that ITO is an inefficient electrode choice as more than 92% of the irradiated laser on the ITO electrodes is transmitted without absorption. Using theoretical, computational, and experimental approaches, we demonstrate that for a given laser power the temperature rise is controlled by both the electrode material and its thickness. A 25-nm thick Ti electrode creates an electrothermal flow of the same speed as a 700-nm thick ITO electrode while requiring only 14% of the laser power used by ITO. These results represent an important step in the design of low-cost portable REP systems by lowering the material cost and power consumption of the system.


Assuntos
Técnicas Eletroquímicas/métodos , Micromanipulação/métodos , Modelos Teóricos , Imagem Óptica/métodos , Eletrodos
6.
Appl Opt ; 55(35): 10025-10029, 2016 Dec 10.
Artigo em Inglês | MEDLINE | ID: mdl-27958406

RESUMO

A simple optical setup is introduced here that is capable of improving the diffraction-limited angular resolution of a telescope at minimal cost to image quality. The system consists of, at minimum, an axicon and a convex lens located in the optical path of the telescope, which can increase the angular resolution by up to 38%. Analytical results for this resolution gain along with the Strehl ratio of this system are presented along with experimental results, which show a 30% improvement in single-acquisition image resolution with a Strehl ratio of 0.07, agreeing well with predicted values. With an ultrashallow axicon, large increases in Strehl ratio are possible, up to and beyond unity making higher angular resolution measurements possible with little cost to image quality or experimental complexity.

7.
Soft Matter ; 11(28): 5619-23, 2015 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-26106879

RESUMO

In this work, we discuss an optical method for measuring surface tension induced menisci. The principle of measurement is based upon the change in the background pattern produced by the curvature of the meniscus acting as a lens. We measure the meniscus profile over an inclined glass plate and utilize the measured meniscus for estimation of surface tension and refractive index.

8.
bioRxiv ; 2024 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-38798664

RESUMO

Sperm cryopreservation is important for individuals undergoing infertility treatment, and for those who wish to preserve fertility potential, prior to treatments like chemotherapy, radiation therapy, gender-affirming medical interventions, elective fertility delay, or individuals in high-risk professions such as the military. Current methods for sperm cryopreservation result in approximately 30-50% decrease in sperm motility. However, recent studies have shown that ultra-rapid freezing (vitrification) is a valuable approach for maintaining sperm quality after freeze-thawing processes in the clinical laboratory setting and requires submicroliter to microliter volumes. A major challenge for the adoption of vitrification in fertility laboratories is the ability to pipette small volumes of sample. Here, we present a method that leverages open-channel droplet microfluidics to autonomously generate sub-microliter to microliter volumes of purified human sperm samples. Using a novel, open-channel droplet generator, we found no change in sperm movement and kinematic data after exposure to device and reagents in our platform. We conclude that our platform is compatible with human sperm, an important foundation for future implementation of vitrification in fertility laboratories.

9.
Phys Fluids (1994) ; 35(8): 082120, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37675268

RESUMO

The search for efficient capillary pumping has led to two main directions for investigation: first, assembly of capillary channels to provide high capillary pressures, and second, imbibition in absorbing fibers or paper pads. In the case of open microfluidics (i.e., channels where the top boundary of the fluid is in contact with air instead of a solid wall), the coupling between capillary channels and paper pads unites the two approaches and provides enhanced capillary pumping. In this work, we investigate the coupling of capillary trees-networks of channels mimicking the branches of a tree-with paper pads placed at the extremities of the channels, mimicking the small capillary networks of leaves. It is shown that high velocities and flow rates (7 mm/s or 13.1 µl/s) for more than 30 s using 50% (v/v) isopropyl alcohol, which has a 3-fold increase in viscosity in comparison to water; 6.5 mm/s or 12.1 µl/s for more than 55 s with pentanol, which has a 3.75-fold increase in viscosity in comparison to water; and >3.5 mm/s or 6.5 µl/s for more than 150 s with nonanol, which has a 11-fold increase in viscosity in comparison to water, can be reached in the root channel, enabling higher sustained flow rates than that of capillary trees alone.

10.
Nat Rev Chem ; 7(6): 439-455, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37117816

RESUMO

Open droplet microfluidic systems manipulate droplets on the picolitre-to-microlitre scale in an open environment. They combine the compartmentalization and control offered by traditional droplet-based microfluidics with the accessibility and ease-of-use of open microfluidics, bringing unique advantages to applications such as combinatorial reactions, droplet analysis and cell culture. Open systems provide direct access to droplets and allow on-demand droplet manipulation within the system without needing pumps or tubes, which makes the systems accessible to biologists without sophisticated setups. Furthermore, these systems can be produced with simple manufacturing and assembly steps that allow for manufacturing at scale and the translation of the method into clinical research. This Review introduces the different types of open droplet microfluidic system, presents the physical concepts leveraged by these systems and highlights key applications.


Assuntos
Biologia , Microfluídica , Microfluídica/métodos
11.
Lab Chip ; 16(16): 3058-64, 2016 08 21.
Artigo em Inglês | MEDLINE | ID: mdl-27194099

RESUMO

This paper describes the dimensionless groups that determine the break-up probability of droplets in a concentrated emulsion during its flow in a tapered microchannel consisting of a narrow constriction. Such channel geometry is commonly used in droplet microfluidics to investigate the content of droplets from a concentrated emulsion. In contrast to solid wells in multi-well plates, drops are metastable, and are prone to break-up which compromises the accuracy and the throughput of the assay. Unlike single drops, the break-up process in a concentrated emulsion is stochastic. Analysis of the behavior of a large number of drops (N > 5000) shows that the probability of break-up increases with applied flow rate, the size of the drops relative to the size of the constriction, and the viscosity ratio of the emulsion. This paper shows that the break-up probability collapses into a single curve when plotted as a function of the product of capillary number, viscosity ratio, and confinement factor defined as the un-deformed radius of the drop relative to the hydraulic radius of the constriction. Fundamentally, the results represent a critical step towards the understanding of the physics governing instability in concentrated emulsions. Practically, the results provide a direct guide for the rational design of microchannels and the choice of operation parameters to increase the throughput of the droplet interrogation step while preserving droplet integrity and assay accuracy.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa