Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
1.
Sensors (Basel) ; 21(5)2021 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-33652955

RESUMO

Saliva can be used for health monitoring with non-invasive wearable systems. Such devices, including electrochemical sensors, may provide a safe, fast, and cost-efficient way of detecting target ions. Although salivary ions are known to reflect those in blood, no available clinical device can detect essential ions directly from saliva. Here, we introduce an all-solid-state, flexible film sensor that allows highly accurate detection of sodium levels in saliva, comparable to those in blood. The wireless film sensor system can successfully measure sodium ions from a small volume of infants' saliva (<400 µL), demonstrating its potential as a continuous health monitor. This study includes the structural characterization and error analysis of a carbon/elastomer-based ion-selective electrode and a reference electrode to confirm the signal reliability. The sensor, composed of a pair of the electrodes, shows good sensitivity (58.9 mV/decade) and selectivity (log K = -2.68 for potassium), along with a broad detection range of 5 × 10-5 ≈ 1 M with a low detection limit of 4.27 × 10-5 M. The simultaneous comparison between the film sensor and a commercial electrochemical sensor demonstrates the accuracy of the flexible sensor and a positive correlation in saliva-to-blood sodium levels. Collectively, the presented study shows the potential of the wireless ion-selective sensor system for a non-invasive, early disease diagnosis with saliva.


Assuntos
Técnicas Biossensoriais , Sódio , Eletrodos , Humanos , Lactente , Eletrodos Seletivos de Íons , Íons , Reprodutibilidade dos Testes , Saliva
2.
Sensors (Basel) ; 20(11)2020 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-32531954

RESUMO

Wireless, flexible, ion-selective electrodes (ISEs) are of great interest in the development of wearable health monitors and clinical systems. Existing film-based electrochemical sensors, however, still have practical limitations due to poor electrical contact and material-interfacial leakage. Here, we introduce a wireless, flexible film-based system with a highly selective, stable, and reliable sodium sensor. A flexible and hydrophobic composite with carbon black and soft elastomer serves as an ion-to-electron transducer offering cost efficiency, design simplicity, and long-term stability. The sensor package demonstrates repeatable analysis of selective sodium detection in saliva with good sensitivity (56.1 mV/decade), stability (0.53 mV/h), and selectivity coefficient of sodium against potassium (-3.0). The film ISEs have an additional membrane coating that provides reinforced stability for the sensor upon mechanical bending. Collectively, the comprehensive study of materials, surface chemistry, and sensor design in this work shows the potential of the wireless flexible sensor system for low-profile wearable applications.


Assuntos
Eletrodos Seletivos de Íons , Sódio/análise , Tecnologia sem Fio , Íons/análise , Potássio/análise
3.
Proc Natl Acad Sci U S A ; 109(49): 19910-5, 2012 Dec 04.
Artigo em Inglês | MEDLINE | ID: mdl-23150574

RESUMO

Curved surfaces, complex geometries, and time-dynamic deformations of the heart create challenges in establishing intimate, nonconstraining interfaces between cardiac structures and medical devices or surgical tools, particularly over large areas. We constructed large area designs for diagnostic and therapeutic stretchable sensor and actuator webs that conformally wrap the epicardium, establishing robust contact without sutures, mechanical fixtures, tapes, or surgical adhesives. These multifunctional web devices exploit open, mesh layouts and mount on thin, bio-resorbable sheets of silk to facilitate handling in a way that yields, after dissolution, exceptionally low mechanical moduli and thicknesses. In vivo studies in rabbit and pig animal models demonstrate the effectiveness of these device webs for measuring and spatially mapping temperature, electrophysiological signals, strain, and physical contact in sheet and balloon-based systems that also have the potential to deliver energy to perform localized tissue ablation.


Assuntos
Materiais Biocompatíveis , Eletrônica Médica/instrumentação , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Coração/fisiologia , Pericárdio/anatomia & histologia , Próteses e Implantes , Animais , Catéteres , Eletrônica Médica/métodos , Desenho de Equipamento/métodos , Coração/anatomia & histologia , Teste de Materiais , Nanotecnologia/métodos , Coelhos , Semicondutores , Seda , Temperatura
4.
Sensors (Basel) ; 15(9): 23459-76, 2015 Sep 16.
Artigo em Inglês | MEDLINE | ID: mdl-26389915

RESUMO

New classes of ultrathin flexible and stretchable devices have changed the way modern electronics are designed to interact with their target systems. Though more and more novel technologies surface and steer the way we think about future electronics, there exists an unmet need in regards to optimizing the fabrication procedures for these devices so that large-scale industrial translation is realistic. This article presents an unconventional approach for facile microfabrication and processing of adhesive-peeled (AP) flexible sensors. By assembling AP sensors on a weakly-adhering substrate in an inverted fashion, we demonstrate a procedure with 50% reduced end-to-end processing time that achieves greater levels of fabrication yield. The methodology is used to demonstrate the fabrication of electrical and mechanical flexible and stretchable AP sensors that are peeled-off their carrier substrates by consumer adhesives. In using this approach, we outline the manner by which adhesion is maintained and buckling is reduced for gold film processing on polydimethylsiloxane substrates. In addition, we demonstrate the compatibility of our methodology with large-scale post-processing using a roll-to-roll approach.


Assuntos
Adesivos/química , Técnicas Biossensoriais/instrumentação , Eletrônica/instrumentação , Microtecnologia/métodos , Elasticidade , Desenho de Equipamento , Vidro , Maleabilidade
5.
J Neurophysiol ; 112(6): 1566-83, 2014 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-24920021

RESUMO

Our understanding of the large-scale population dynamics of neural activity is limited, in part, by our inability to record simultaneously from large regions of the cortex. Here, we validated the use of a large-scale active microelectrode array that simultaneously records 196 multiplexed micro-electrocortigraphical (µECoG) signals from the cortical surface at a very high density (1,600 electrodes/cm(2)). We compared µECoG measurements in auditory cortex using a custom "active" electrode array to those recorded using a conventional "passive" µECoG array. Both of these array responses were also compared with data recorded via intrinsic optical imaging, which is a standard methodology for recording sound-evoked cortical activity. Custom active µECoG arrays generated more veridical representations of the tonotopic organization of the auditory cortex than current commercially available passive µECoG arrays. Furthermore, the cortical representation could be measured efficiently with the active arrays, requiring as little as 13.5 s of neural data acquisition. Next, we generated spectrotemporal receptive fields from the recorded neural activity on the active µECoG array and identified functional organizational principles comparable to those observed using intrinsic metabolic imaging and single-neuron recordings. This new electrode array technology has the potential for large-scale, temporally precise monitoring and mapping of the cortex, without the use of invasive penetrating electrodes.


Assuntos
Córtex Auditivo/fisiologia , Mapeamento Encefálico/instrumentação , Eletroencefalografia/instrumentação , Animais , Mapeamento Encefálico/métodos , Eletroencefalografia/métodos , Potenciais Evocados Auditivos , Masculino , Microeletrodos , Imagem Óptica/métodos , Ratos
6.
Nat Mater ; 12(10): 938-44, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24037122

RESUMO

Precision thermometry of the skin can, together with other measurements, provide clinically relevant information about cardiovascular health, cognitive state, malignancy and many other important aspects of human physiology. Here, we introduce an ultrathin, compliant skin-like sensor/actuator technology that can pliably laminate onto the epidermis to provide continuous, accurate thermal characterizations that are unavailable with other methods. Examples include non-invasive spatial mapping of skin temperature with millikelvin precision, and simultaneous quantitative assessment of tissue thermal conductivity. Such devices can also be implemented in ways that reveal the time-dynamic influence of blood flow and perfusion on these properties. Experimental and theoretical studies establish the underlying principles of operation, and define engineering guidelines for device design. Evaluation of subtle variations in skin temperature associated with mental activity, physical stimulation and vasoconstriction/dilation along with accurate determination of skin hydration through measurements of thermal conductivity represent some important operational examples.


Assuntos
Temperatura Cutânea , Termometria/instrumentação , Adulto , Epiderme/fisiologia , Humanos , Masculino , Processos Mentais/fisiologia , Estimulação Física , Descanso , Fatores de Tempo
7.
Sci Adv ; 10(7): eadk6714, 2024 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-38354246

RESUMO

Achieving large-scale, cost-effective, and reproducible manufacturing of stem cells with the existing devices is challenging. Traditional single-use cell-bag bioreactors, limited by their rigid and single-point sensors, struggle with accuracy and scalability for high-quality cell manufacturing. Here, we introduce a smart bioreactor system that enables multi-spatial sensing for real-time, wireless culture monitoring. This scalable system includes a low-profile, label-free thin-film sensor array and electronics integrated with a flexible cell bag, allowing for simultaneous assessment of culture properties such as pH, dissolved oxygen, glucose, and temperature, to receive real-time feedback for up to 30 days. The experimental results show the accurate monitoring of time-dynamic and spatial variations of stem cells and myoblast cells with adjustable carriers from a plastic dish to a 2-liter cell bag. These advances open up the broad applicability of the smart sensing system for large-scale, lower-cost, reproducible, and high-quality engineered cell manufacturing for broad clinical use.


Assuntos
Eletrônica , Dispositivos Eletrônicos Vestíveis , Técnicas de Cultura de Células , Reatores Biológicos , Células-Tronco
8.
ACS Appl Electron Mater ; 5(2): 877-886, 2023 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-36873262

RESUMO

Recent advances in wearable technologies have enabled ways for people to interact with external devices, known as human-machine interfaces (HMIs). Among them, electrooculography (EOG), measured by wearable devices, is used for eye movement-enabled HMI. Most prior studies have utilized conventional gel electrodes for EOG recording. However, the gel is problematic due to skin irritation, while separate bulky electronics cause motion artifacts. Here, we introduce a low-profile, headband-type, soft wearable electronic system with embedded stretchable electrodes, and a flexible wireless circuit to detect EOG signals for persistent HMIs. The headband with dry electrodes is printed with flexible thermoplastic polyurethane. Nanomembrane electrodes are prepared by thin-film deposition and laser cutting techniques. A set of signal processing data from dry electrodes demonstrate successful real-time classification of eye motions, including blink, up, down, left, and right. Our study shows that the convolutional neural network performs exceptionally well compared to other machine learning methods, showing 98.3% accuracy with six classes: the highest performance till date in EOG classification with only four electrodes. Collectively, the real-time demonstration of continuous wireless control of a two-wheeled radio-controlled car captures the potential of the bioelectronic system and the algorithm for targeting various HMI and virtual reality applications.

9.
Sci Adv ; 9(21): eadg9671, 2023 05 24.
Artigo em Inglês | MEDLINE | ID: mdl-37224243

RESUMO

Although many people suffer from sleep disorders, most are undiagnosed, leading to impairments in health. The existing polysomnography method is not easily accessible; it's costly, burdensome to patients, and requires specialized facilities and personnel. Here, we report an at-home portable system that includes wireless sleep sensors and wearable electronics with embedded machine learning. We also show its application for assessing sleep quality and detecting sleep apnea with multiple patients. Unlike the conventional system using numerous bulky sensors, the soft, all-integrated wearable platform offers natural sleep wherever the user prefers. In a clinical study, the face-mounted patches that detect brain, eye, and muscle signals show comparable performance with polysomnography. When comparing healthy controls to sleep apnea patients, the wearable system can detect obstructive sleep apnea with an accuracy of 88.5%. Furthermore, deep learning offers automated sleep scoring, demonstrating portability, and point-of-care usability. At-home wearable electronics could ensure a promising future supporting portable sleep monitoring and home healthcare.


Assuntos
Síndromes da Apneia do Sono , Qualidade do Sono , Humanos , Polissonografia , Sono , Síndromes da Apneia do Sono/diagnóstico , Encéfalo
10.
Nat Mater ; 10(4): 316-23, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21378969

RESUMO

Developing advanced surgical tools for minimally invasive procedures represents an activity of central importance to improving human health. A key challenge is in establishing biocompatible interfaces between the classes of semiconductor device and sensor technologies that might be most useful in this context and the soft, curvilinear surfaces of the body. This paper describes a solution based on materials that integrate directly with the thin elastic membranes of otherwise conventional balloon catheters, to provide diverse, multimodal functionality suitable for clinical use. As examples, we present sensors for measuring temperature, flow, tactile, optical and electrophysiological data, together with radiofrequency electrodes for controlled, local ablation of tissue. Use of such 'instrumented' balloon catheters in live animal models illustrates their operation, as well as their specific utility in cardiac ablation therapy. The same concepts can be applied to other substrates of interest, such as surgical gloves.


Assuntos
Ablação por Cateter/instrumentação , Cateterismo/instrumentação , Catéteres , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Animais , Desenho de Equipamento , Teste de Materiais , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos , Suínos
11.
Sci Adv ; 8(21): eabo5867, 2022 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-35613271

RESUMO

Modern auscultation, using digital stethoscopes, provides a better solution than conventional methods in sound recording and visualization. However, current digital stethoscopes are too bulky and nonconformal to the skin for continuous auscultation. Moreover, motion artifacts from the rigidity cause friction noise, leading to inaccurate diagnoses. Here, we report a class of technologies that offers real-time, wireless, continuous auscultation using a soft wearable system as a quantitative disease diagnosis tool for various diseases. The soft device can detect continuous cardiopulmonary sounds with minimal noise and classify real-time signal abnormalities. A clinical study with multiple patients and control subjects captures the unique advantage of the wearable auscultation method with embedded machine learning for automated diagnoses of four types of lung diseases: crackle, wheeze, stridor, and rhonchi, with a 95% accuracy. The soft system also demonstrates the potential for a sleep study by detecting disordered breathing for home sleep and apnea detection.

12.
Adv Healthc Mater ; 11(13): e2200170, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35306761

RESUMO

Hotter summers caused by global warming and increased workload and duration are endangering the health of farmworkers, a high-risk population for heat-related illness (HRI), and deaths. Although prior studies using wearable sensors show the feasibility of employing field-collected data for HRI monitoring, existing devices still have limitations, such as data loss from motion artifacts, device discomfort from rigid electronics, difficulties with administering ingestible sensors, and low temporal resolution. Here, this paper introduces a wireless, wearable bioelectronic system with functionalities for continuous monitoring of skin temperature, electrocardiograms (ECG), heart rates (HR), and activities, configured in a single integrated package. Advanced nanomanufacturing based on laser machining allows rapid device fabrication and direct incorporation of sensors with a highly breathable substrate, allowing for managing excessive sweating and multimodal stresses. To validate the device's performance in agricultural settings, the device is applied to multiple farmworkers at various operations, including fernery, nursery, and crop. The accurate data recording, including high-fidelity ECG (signal-to-noise ratio: >20 dB), accurate HR (r = 0.89, r2 = 0.65 in linear correlation), and reliable temperature/activity, confirms the device's capability for multiparameter health monitoring of farmworkers.


Assuntos
Fazendeiros , Dispositivos Eletrônicos Vestíveis , Eletrônica , Frequência Cardíaca , Temperatura Alta , Humanos , Tecnologia sem Fio
13.
Nat Mater ; 9(6): 511-7, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20400953

RESUMO

Electronics that are capable of intimate, non-invasive integration with the soft, curvilinear surfaces of biological tissues offer important opportunities for diagnosing and treating disease and for improving brain/machine interfaces. This article describes a material strategy for a type of bio-interfaced system that relies on ultrathin electronics supported by bioresorbable substrates of silk fibroin. Mounting such devices on tissue and then allowing the silk to dissolve and resorb initiates a spontaneous, conformal wrapping process driven by capillary forces at the biotic/abiotic interface. Specialized mesh designs and ultrathin forms for the electronics ensure minimal stresses on the tissue and highly conformal coverage, even for complex curvilinear surfaces, as confirmed by experimental and theoretical studies. In vivo, neural mapping experiments on feline animal models illustrate one mode of use for this class of technology. These concepts provide new capabilities for implantable and surgical devices.


Assuntos
Eletrônica/métodos , Fibroínas , Seda , Animais , Ação Capilar , Gatos , Eletrodos , Eletrônica/instrumentação , Microscopia Confocal/métodos , Modelos Animais , Polimetil Metacrilato , Próteses e Implantes , Solubilidade , Estresse Mecânico , Instrumentos Cirúrgicos
14.
Adv Healthc Mater ; 10(22): e2101400, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34486237

RESUMO

Acoustic stethoscopes have demonstrated beneficial factors aiding diagnosis from the doctors with accurate body sounds. Still, the conventional acoustic stethoscopes require a substantial amount of clinical experience and hearing skills for the physicians to accurately diagnose symptoms from abnormal sounds. Especially for cardiopulmonary systems, it is crucial to collect sounds with precision since they contain valuable information in specific frequency ranges for various sounds. This review paper summarizes recent advances and technical developments in microsensors, circuits, chips, and integrated electronics for fabricating different digital stethoscopes that offer portable detection of body sounds. They solve the limitations of conventional stethoscopes, aiming for wireless auscultation in digitized medicine. Overall, this comprehensive review will help researchers design and develop new wearable electronics and digital stethoscopes for advancing human healthcare, continuous monitoring, and better diagnosis.


Assuntos
Estetoscópios , Dispositivos Eletrônicos Vestíveis , Acústica , Auscultação , Eletrônica , Humanos
15.
Adv Sci (Weinh) ; 8(19): e2101129, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34272934

RESUMO

Motor imagery offers an excellent opportunity as a stimulus-free paradigm for brain-machine interfaces. Conventional electroencephalography (EEG) for motor imagery requires a hair cap with multiple wired electrodes and messy gels, causing motion artifacts. Here, a wireless scalp electronic system with virtual reality for real-time, continuous classification of motor imagery brain signals is introduced. This low-profile, portable system integrates imperceptible microneedle electrodes and soft wireless circuits. Virtual reality addresses subject variance in detectable EEG response to motor imagery by providing clear, consistent visuals and instant biofeedback. The wearable soft system offers advantageous contact surface area and reduced electrode impedance density, resulting in significantly enhanced EEG signals and classification accuracy. The combination with convolutional neural network-machine learning provides a real-time, continuous motor imagery-based brain-machine interface. With four human subjects, the scalp electronic system offers a high classification accuracy (93.22 ± 1.33% for four classes), allowing wireless, real-time control of a virtual reality game.


Assuntos
Interfaces Cérebro-Computador , Encéfalo/fisiologia , Eletroencefalografia/instrumentação , Eletroencefalografia/métodos , Interface Usuário-Computador , Realidade Virtual , Eletrodos , Humanos , Couro Cabeludo
16.
Sci Adv ; 7(52): eabl4146, 2021 Dec 24.
Artigo em Inglês | MEDLINE | ID: mdl-34936438

RESUMO

Obstructive sleep apnea (OSA) affects more than 900 million adults globally and can create serious health complications when untreated; however, 80% of cases remain undiagnosed. Critically, current diagnostic techniques are fundamentally limited by low throughputs and high failure rates. Here, we report a wireless, fully integrated, soft patch with skin-like mechanics optimized through analytical and computational studies to capture seismocardiograms, electrocardiograms, and photoplethysmograms from the sternum, allowing clinicians to investigate the cardiovascular response to OSA during home sleep tests. In preliminary trials with symptomatic and control subjects, the soft device demonstrated excellent ability to detect blood-oxygen saturation, respiratory effort, respiration rate, heart rate, cardiac pre-ejection period and ejection timing, aortic opening mechanics, heart rate variability, and sleep staging. Last, machine learning is used to autodetect apneas and hypopneas with 100% sensitivity and 95% precision in preliminary at-home trials with symptomatic patients, compared to data scored by professionally certified sleep clinicians.

17.
ACS Appl Mater Interfaces ; 12(2): 3059-3067, 2020 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-31842536

RESUMO

Among the various methods to develop flexible wearable antennas, a serpentine, mesh structure has been a great interest because of its mechanical reliability upon applied strain. However, there is still a significant lack of design guidelines for the open-mesh concept that account for both material and electromagnetic (EM) properties of antennas. In this work, we introduce a comprehensive study of materials, mechanics, fabrication, and system integration for the development of stretchable dipole and patch antennas that have networks of two-dimensional serpentine patterns. A set of computational modeling and experimental validation of open-mesh structures provides the key design guidelines to offer the maximum mechanical stretchability and minimum effective moduli of wearable antennas. Integration of the thin-film antenna traces with various substrates captures the versatility of the deterministic fabrication and material transfer printing methods. The influence of antenna stretching on the EM properties, including return loss, electric and magnetic fields, and far-field radiation patterns, is investigated. EM characterization with mechanical stretching results in different properties of fabricated antennas. The simulation study of specific absorption rates shows a potential for safe applications of dipole and patch stretchable antennas on the human skin.


Assuntos
Teste de Materiais , Desenho de Prótese , Dispositivos Eletrônicos Vestíveis , Absorção de Radiação , Fenômenos Eletromagnéticos , Humanos
18.
Biosens Bioelectron ; 173: 112764, 2020 Nov 04.
Artigo em Inglês | MEDLINE | ID: mdl-33190046

RESUMO

Stress has become a significant factor, directly affecting human health. Due to the numerous sources of stress that are inevitable in daily life, effective management of stress is essential to maintain a healthy life. Recent advancements in wearable devices allow monitoring stress levels via the detection of galvanic skin response on the skin. Some of these devices show the capability of assessing stress relief methods. However, prior works have been limited in a controlled laboratory setting with a short period assessment (<1 h) of stress intervention. The existing systems' main issues include motion artifacts and discomfort caused by rigid and bulky electronics and mandatory device connection on active fingers. Here, we introduce soft, wireless, skin-like electronics (SKINTRONICS) that offers continuous, portable daily stress and management practice monitoring. The ultrathin, lightweight, all-in-one device captures the change of a subject's stress over six continuous hours during everyday activities, including desk work, cleaning, and resting. At the same time, the SKINTRONICS proves that typical stress alleviation methods (mindfulness and meditation) can reduce stress levels, even in the middle of the day, which is supported by statistical analysis. The low-profile, wireless, gel-free device shows enhanced breathability and minimized motion artifacts compared to a commercial stress monitor. Collectively, this study shows the first demonstration of soft, nanomembrane bioelectronics for long-term, continuous assessment of stress and intervention effectiveness throughout daily life.

19.
ACS Appl Mater Interfaces ; 12(44): 49398-49406, 2020 Nov 04.
Artigo em Inglês | MEDLINE | ID: mdl-33085453

RESUMO

Recent advances in flexible materials and wearable electronics offer a noninvasive, high-fidelity recording of biopotentials for portable healthcare, disease diagnosis, and machine interfaces. Current device-manufacturing methods, however, still heavily rely on the conventional cleanroom microfabrication that requires expensive, time-consuming, and complicated processes. Here, we introduce an additive nanomanufacturing technology that explores a contactless direct printing of aerosol nanomaterials and polymers to fabricate stretchable sensors and multilayered wearable electronics. Computational and experimental studies prove the mechanical flexibility and reliability of soft electronics, considering direct mounting to the deformable human skin with a curvilinear surface. The dry, skin-conformal graphene biosensor, without the use of conductive gels and aggressive tapes, offers an enhanced biopotential recording on the skin and multiple uses (over ten times) with consistent measurement of electromyograms. The combination of soft bioelectronics and deep learning algorithm allows classifying six classes of muscle activities with an accuracy of over 97%, which enables wireless, real-time, continuous control of external machines such as a robotic hand and a robotic arm. Collectively, the comprehensive study of nanomaterials, flexible mechanics, system integration, and machine learning shows the potential of the printed bioelectronics for portable, smart, and persistent human-machine interfaces.


Assuntos
Algoritmos , Aprendizado Profundo , Eletrônica , Nanotecnologia , Dispositivos Eletrônicos Vestíveis , Humanos , Tamanho da Partícula , Propriedades de Superfície
20.
IEEE Trans Biomed Eng ; 67(11): 3094-3100, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32091988

RESUMO

Blepharospasm (BL) is characterized by involuntary closures of the eyelids due to spasms of the orbicularis oculi muscle. The gold standard for clinical evaluation of BL involves visual inspection for manual rating scales. This approach is highly subjective and error prone. Unfortunately, there are currently no simple quantitative systems for accurate and objective diagnostics of BL. Here, we introduce a soft, flexible hybrid bioelectronic system that offers highly conformal, gentle lamination on the skin, while enabling wireless, quantitative detection of electrophysiological signals. Computational and experimental studies of soft materials and flexible mechanics provide a set of key fundamental design factors for a low-profile bioelectronic system. The nanomembrane soft electrodes, mounted around the eyes, are capable of accurately measuring clinical symptoms, including the frequency of blinking, the duration of eye closures during spasms, as well as combinations of blinking and spasms. The use of a deep-learning, convolutional neural network, with the bioelectronics offers objective, real-time classification of key pathological features in BL. The wearable bioelectronics outperform the conventional manual clinical rating, as shown by a pilot study with 13 patients. In vivo demonstration of the bioelectronics with these patients indicates the device as an easy-to-use solution for objective quantification of BL.


Assuntos
Blefarospasmo , Dispositivos Eletrônicos Vestíveis , Blefarospasmo/diagnóstico , Eletrodos , Humanos , Redes Neurais de Computação , Projetos Piloto
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa