Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 110
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Europace ; 25(1): 83-91, 2023 02 08.
Artigo em Inglês | MEDLINE | ID: mdl-35851807

RESUMO

AIMS: The usefulness of catheter ablation (CA) for atrial fibrillation (AF) across a broad spectrum of heart failure (HF) patients remains to be established. We assessed the association of CA with both health-related quality of life (QoL) and cardiovascular events among HF patients with reduced and preserved left ventricular ejection fraction (LVEF) in an 'all-comer' outpatient-based AF registry. METHODS AND RESULTS: Of 3303 patients with AF consecutively enrolled in a retrospective multicentre registry that mandated the Atrial Fibrillation Effect on QualiTy-of-life (AFEQT) questionnaire at registration and 1-year follow-up, we extracted data from 530 patients complicating clinical HF. The association between CA and both 1-year change in AFEQT Overall Summary (AFEQT-OS) scores and 2-year composite clinical outcomes (including all-cause death, stroke, and HF hospitalization) was assessed by multivariable analyses. The median duration of AF was 108 days (52-218 days), and 83.4% had LVEF >35%. Overall, 75 patients (14.2%) underwent CA for AF within 1-year after registration. At 1-year follow-up, 67.2% in the ablation group showed clinically meaningful improvements of ≥ 5 points in AFEQT-OS score than 47.8% in the non-ablation group {adjusted odds ratio, 2.03 [95% confidence interval (CI): 1.13-3.64], P = 0.017}. Furthermore, the composite endpoint of all-cause death, stroke, and HF hospitalization occurred less frequently in the ablation group than the non-ablation group [adjusted hazard ratio, 0.27 (95% CI: 0.09-0.86), P = 0.027]. CONCLUSION: Among AF-HF patients, CA was associated with improved QoL and lower risk of cardiovascular events against drug therapy alone, even for patients with mildly reduced and preserved LVEF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Insuficiência Cardíaca , Acidente Vascular Cerebral , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/complicações , Volume Sistólico/fisiologia , Função Ventricular Esquerda/fisiologia , Qualidade de Vida , Resultado do Tratamento , Acidente Vascular Cerebral/complicações , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Estudos de Coortes
2.
Europace ; 25(7)2023 07 04.
Artigo em Inglês | MEDLINE | ID: mdl-37395219

RESUMO

AIMS: Linear lesions are routinely created by radiofrequency catheter ablation. Unwanted electrical conduction gaps can be produced and are often difficult to ablate. This study aimed to clarify the characteristics of conduction gaps during atrial fibrillation ablation by analysing bidirectional activation maps using a high-density mapping system (RHYTHMIA). METHODS AND RESULTS: This retrospective study included 31 patients who had conduction gaps along pulmonary vein (PV) isolation or box ablation lesions. Activation maps were sequentially created during pacing from the coronary sinus and PV to reveal the earliest activation site, defined by the entrance and exit. The locations, length between the entrance and exit (gap length), and direction were analysed. Thirty-four bidirectional activation maps were drawn: 21 were box isolation lesions (box group), and 13 were PV isolation lesions (PVI group). Among the box group, nine conduction gaps were present in the roof region and 12 in the bottom region, while nine in right PV and four in left PV among the PVI group. Gap lengths in the roof region were longer than those in the bottom region (26.8 ± 11.8 vs. 14.5 ± 9.8 mm; P = 0.022), while those in right PV tended to longer than those in left PV (28.0 ± 15.3 vs. 16.8 ± 8.0 mm, P = 0.201). CONCLUSION: The entrances and exits of electrical conduction gaps were separated, especially in the roof region, indicating that epicardial conduction might contribute to gap formation. Identifying the bidirectional conduction gap might indicate the location and direction of epicardial conduction.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Sistema de Condução Cardíaco/cirurgia , Estudos Retrospectivos , Frequência Cardíaca , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Resultado do Tratamento
3.
J Orthop Sci ; 28(6): 1274-1278, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36609035

RESUMO

BACKGROUND: The management of pain in patients with rotator cuff tears can be challenging. Neuropathic pain is reportedly associated with pain occurrence in musculoskeletal diseases. However, to date, few studies have reported on the prevalence of neuropathic pain in patients with rotator cuff tears or identified the factors associated with neuropathic pain in a multicenter study. METHODS: A total of 391 patients (205 males and 186 females; median age, 67.7 years; range, 27-92 years) with rotator cuff tears were included in this study. The prevalence of neuropathic pain in rotator cuff tears was investigated using the Japanese version of the painDETECT questionnaire for all patients. In addition, factors significantly associated with the occurrence of neuropathic pain were examined using multivariate logistic regression analysis. RESULTS: Twenty-eight patients (7.2%) were classified into the neuropathic pain group (score ≥19), 97 (24.8%) into the uncertainty regarding neuropathy group (score 13-18), and 266 (68.0%) into the nociceptive pain group (score ≤12). According to the multivariate logistic regression analysis, the independent predictors of neuropathic pain were the VAS score (most severe pain during the past 4 weeks; odds ratio, 1.55; 95% confidence interval [CI], 1.23-2.09) and UCLA shoulder score (odds ratio, 0.81; 95% CI, 0.65-0.97). CONCLUSIONS: Based on the study findings, the prevalence of neuropathic pain in patients with rotator cuff tear was 7.2%. It is important to investigate the presence or absence of neuropathic pain when treating patients with painful rotator cuff tears, because neuropathy associated with rotator cuff tears may adversely affect patient outcomes.


Assuntos
Neuralgia , Lesões do Manguito Rotador , Masculino , Feminino , Humanos , Idoso , Lesões do Manguito Rotador/complicações , Lesões do Manguito Rotador/epidemiologia , Prevalência , Dor de Ombro/diagnóstico , Dor de Ombro/epidemiologia , Dor de Ombro/etiologia , Neuralgia/diagnóstico , Neuralgia/epidemiologia , Neuralgia/etiologia , Causalidade
4.
Am Heart J ; 254: 156-165, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36099976

RESUMO

BACKGROUND: Recent randomized clinical trials have demonstrated that applying rhythm control during the early stage of atrial fibrillation (AF) may lead to improved clinical outcomes. However, the effects of this modality on health-related quality of life (HRQoL) have not been fully investigated. We aimed to assess the association between the AF stage, determined by the time between AF diagnosis and referral to the cardiology clinic, and HRQoL outcomes. METHODS: Using an outpatients-based multicenter AF registry (n = 3,313), we analyzed 2,070 patients with AF diagnosed within 5 years. The patients were divided into 2 groups according to AF stage: early and late AF (AF duration ≤1 and >1 year, respectively). All patients had HRQoL information collected at baseline and 1 year after their initial treatment (assessed via the Atrial Fibrillation Effect on Quality-of-Life-overall summary [AFEQT-OS] score, with higher scores reflecting better HRQoL). The change in AFEQT-OS was adjusted for patient characteristics using a generalized linear mixed model. RESULTS: The early AF group (n = 1,644) was older (early, 68.5 ± 11.1, late, 64.4 ± 10.6 years, P < .001) and had more heart failure (early, 19.9%, late, 12.7%, P < .001) than the late AF group (n = 426). At 1 year after treatment, the adjusted changes in AFEQT-OS were similar in patients with rhythm (adjusted difference [SE], early, 8.4 [1.2], late, 7.2 [1.4], P = .15) or rate (early, 4.0 [0.7], late, 2.3 [1.4], P = .16) control, regardless of AF stage. Furthermore, the improvement in HRQoL was similar between early and late AF in patients undergoing catheter ablation (early, 10.2 [2.1], late, 9.8 [2.4], P = .78), whereas a significant difference was observed in those receiving antiarrhythmic drug therapy alone (early, 10.2 [1.4], late, 3.5 [2.2], P < .001). CONCLUSIONS: Rhythm control therapy provided clinically meaningful improvements in HRQoL, regardless of AF stage. For patients with impaired HRQoL, AF duration should not be a deterrent to treatment, especially catheter ablation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/terapia , Fibrilação Atrial/tratamento farmacológico , Qualidade de Vida , Antiarrítmicos/uso terapêutico , Sistema de Registros , Resultado do Tratamento
5.
Heart Vessels ; 36(2): 267-276, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32902701

RESUMO

Atrial fibrillation (AF) is known to aggregate within family and might be associated with a lower quality-of-life (QoL). We evaluated the association between a family history (FHx) of AF and patient-reported symptom burden and perception towards treatment. We performed a retrospective analysis in a cohort of 1285 newly diagnosed patients with AF. Patients completed the atrial fibrillation effect on quality of life (AFEQT) questionnaire at the time of registration and at the 1-year follow-up. Patients who had a first-degree relative with AF were classified into the FHx group. Baseline characteristics and AFEQT scores were compared between groups, and a multivariate analysis was used to evaluate the independent association between FHx and QoL. Overall, 15.9% of patients (n = 204) had a positive AF FHx. Compared to the non-FHx group, the FHx group had an earlier onset of AF (60.2 ± 12.0 years vs. 64.5 ± 12.1 years; P < 0.05) and lower AFEQT overall summary (AFEQT-OS) score at baseline (73.9 ± 17.8 vs. 77.0 ± 16.8; P < 0.05). After adjustment for clinical background, a positive FHx was independently associated with a worse QoL (changes in AFEQT-OS score = - 3.18; 95% confidence interval: - 5.67 to - 0.69; P = 0.012). No between-group difference in AFEQT-OS scores was noted at the 1-year follow-up. An FHx of AF was associated with a lower QoL, which could be improved by therapeutic intervention in patients with AF. Recognizing the presence of an FHx of AF is important to predict patient's symptom load and treatment acceptance.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Percepção , Qualidade de Vida/psicologia , Sistema de Registros , Idoso , Fibrilação Atrial/psicologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Inquéritos e Questionários
6.
Knee Surg Sports Traumatol Arthrosc ; 29(8): 2587-2594, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33459835

RESUMO

PURPOSE: The Stump classification is significantly correlated with a retear after arthroscopic rotator cuff repair. However, no study has evaluated whether or not the stump classification is correlated with retear in the suture-bridge or double-row repair techniques. The aim of this study was to evaluate the relationship between a retear and the stump classification in the suture-bridge and double-row repair techniques. METHODS: Among 389 patients who underwent arthroscopic repairs of full-thickness rotator cuff tears using suture-bridge or double-row repair techniques, 326 patients (median age 67.0 years; range 25-85) were included. There were 51 small, 172 medium, 83 large, and 20 massive tears. Two hundred forty patients were treated with the suture-bridge technique, and 86 patients were treated with the double-row technique. The following variables were analyzed: age, sex, the Cofield classification, anteroposterior and mediolateral tear size on preoperative MRI, global fatty degeneration index, and the stump classification. Cuff integrity was evaluated on magnetic resonance imaging at 6 months after surgery. The patients were divided into the intact and retear groups and the relationship between the variables and retear was evaluated by multivariate logistic regression analysis. RESULTS: The overall retear rate was 10.1%. In the multivariate logistic regression analysis, the independent predictors of a retear were the stump classification type 3 (Odds ratio: 4.71, p = 0.0246), global fatty degeneration index (Odds ratio: 3.87, p = 0.0030), and anteroposterior tear size (Odds ratio: 1.07, p = 0.0077) in the suture bridge technique. In the double-row technique, the independent predictors of retear were stump classification type 3 (Odds ratio: 7.82, p = 0.0348), and age (Odds ratio: 1.22, p = 0.0163). CONCLUSION: The stump classification was significantly correlated with retear in the suture-bridge and double-row repair technique. Stump classification type 3 was indicated to be an important risk factor for predicting retear. LEVEL OF EVIDENCE: III.


Assuntos
Lesões do Manguito Rotador , Manguito Rotador , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroscopia , Humanos , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade , Estudos Retrospectivos , Manguito Rotador/cirurgia , Lesões do Manguito Rotador/cirurgia , Técnicas de Sutura , Suturas , Resultado do Tratamento
7.
Am Heart J ; 226: 240-249, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32517853

RESUMO

Our aim was to investigate the variability in physician recognition of atrial fibrillation (AF)-related symptoms, which greatly contributes to the management of AF patients. METHODS AND RESULTS: A total of 1493 newly-referredAF patients (67 ±â€¯11 y/o, 1057 men) consecutively registered in an outpatient-based Japanese multicenter database (KiCS-AF) from September 2012 to December 2016 were analyzed. Self-reportedAF symptom burden was assessed via symptom and daily activities domains within the Atrial Fibrillation Effect on QualiTy-of-life (AFEQT) questionnaire. Physician symptom under-recognition (UR) was defined as no subjective complaints recorded in the medical records despite AFEQT score of <80; and physician's apparent over-recognition (OvR) was defined as documentation of subjective complaints despite total AFEQT score of ≥80. There was poor agreement between patient-reported and physicians-estimated symptom burden (kappa 0.28, 95% CI 0.23 to 0.33). In the logistic regression analysis, age> 75 (odds ratio [OR], 1.72; 95% confidence interval [CI], 1.13-2.62), male sex (OR, 1.82; 95% CI, 1.22-2.74), and persistent/permanent AF (OR 2.54/3.36; CI, 1.63-3.99/1.91-5.89, respectively) were predictors of UR. Conversely, heart failure (OR, 2.46; 95% CI, 1.44-4.25) and treatment in an ablation facility (OR, 1.43; 95% CI, 1.02-2.02) were associated with greater odds of OvR in addition to age, sex, and type of AF. CONCLUSIONS: Discordance in recognition of AF symptom burden by physicians was frequent in AF patients seen in outpatient management and involved both patient- and physician-related factors.


Assuntos
Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Estudos Prospectivos , Sistema de Registros , Índice de Gravidade de Doença , Avaliação de Sintomas
8.
Am Heart J ; 222: 83-92, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32028139

RESUMO

BACKGROUND: Rhythm-control strategy, including catheter ablation (CA) application, constitutes an integral part of atrial fibrillation (AF) management. However, elderly patients are underrepresented in clinical trials, and reports on patient-reported outcome of various rhythm-control treatments remain limited. Therefore, we aimed to investigate the application of a rhythm-control strategy for elderly patients with AF. METHODS: Using a prospective, multicenter Japanese registry, we analyzed 733 patients with AF aged ≥70 years who completed the Atrial Fibrillation Effect on Quality-of-Life (AFEQT) questionnaire at baseline and 1-year visit. Improvement in patient-reported quality-of-life (QOL) was assessed according to their initial treatment strategy. RESULTS: A total of 321 patients (43.8%) were managed with rhythm-control strategy, of which 125 (17.1%) received treatment with antiarrhythmic drugs (AADs) alone and 196 (26.7%) underwent CA. Compared with the rate-control group, the rhythm-control group was younger and less likely to have comorbid conditions but had lower baseline AFEQT-overall summary (OS) scores (71.8 [standard deviation 20.3] vs. 80.0 [standard deviation 16.1]; P < .001). After the first year, AFEQT-OS scores improved regardless of treatment strategies (ie, rate- or rhythm-control). After adjusting for confounders, CA implementation and a lower baseline AFEQT score were associated with meaningful improvement in QOL (changes in AFEQT-OS score ≥5). QOL improvement among subgroups of rhythm-control patients with AADs alone was not clinically meaningful. CONCLUSIONS: In contemporary Japanese clinical practice, rhythm-control strategy is widely implemented in elderly patients with AF, and CA use is associated with improvement in QOL in carefully selected patients.


Assuntos
Antiarrítmicos/uso terapêutico , Fibrilação Atrial/terapia , Ablação por Cateter/métodos , Medidas de Resultados Relatados pelo Paciente , Guias de Prática Clínica como Assunto , Melhoria de Qualidade/normas , Qualidade de Vida , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/fisiopatologia , Feminino , Seguimentos , Frequência Cardíaca/fisiologia , Humanos , Masculino , Estudos Prospectivos , Sistema de Registros , Inquéritos e Questionários
9.
J Cardiovasc Electrophysiol ; 31(8): 1964-1969, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32530529

RESUMO

INTRODUCTION: An electrical superior vena cava (SVC) isolation from the right atrium (RA) sometimes can be challenging. For a safe and efficient SVC isolation, we aimed to visualize the accurate position of the SVC-RA junction on a three-dimensional (3D) mapping system using the decremental conduction properties of the SVC-RA junction in patients with atrial fibrillation (AF). METHODS: This study consisted of 15 consecutive AF patients (11 males, age 59 ± 10 years). A 3D mapping catheter was positioned in the SVC-RA junction region while delivering a single extra-stimulus from the right atrial appendage (RAA), to discriminate the RA and SVC potentials. The electrophysiological SVC-RA junction was defined as the most proximal points where the SVC potentials were recorded, which were tagged on the 3D mapping system around the SVC-RA junction, where radiofrequency energy applications were applied. RESULTS: Around the SVC-RA junction, 9 ± 2 points were tagged on the 3D mapping system. The highest and lowest SVC-RA junction points were located on the anterior wall and posterior wall, respectively. The difference in the level between the highest and lowest SVC-RA junction points was 16.2 ± 6.3 mm. A successful SVC isolation was obtained in all patients without any complications. CONCLUSION: The plane of the electrophysiologically defined SVC-RA junction was not perpendicular to the body axis, but slanted due to the anterior side being higher. Recognizing the precise location of the SVC-RA junction would contribute to a safe and efficacious SVC isolation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Criança , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Humanos , Masculino , Veia Cava Superior/diagnóstico por imagem , Veia Cava Superior/cirurgia
10.
Pacing Clin Electrophysiol ; 43(11): 1289-1294, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-33058199

RESUMO

BACKGROUND: The anatomical changes in pulmonary veins (PVs) after cryoballoon ablation (CBA) are unclear. We aimed to determine the morphological changes in the PVs and left atrium (LA) along with the predictive factors for clinical PV stenosis. METHODS: We analyzed data of 320 PVs from 80 patients who underwent CBA for atrial fibrillation (age: 62 ± 10 years, 59 males). All patients underwent pre- and post-procedural cardiac computed tomography. We defined clinical PV stenosis when the cross-sectional area decreased by more than 50%. RESULTS: The average ostial PV area and LA volume decreased significantly after CBA (pre- vs post-CBA; 2.4 ± 1.0 cm2 vs 2.3±1.1 cm2 , P < .001, 75.0 ± 23.2 cm3 vs 70.7 ± 21.9 cm3 , P < .001, respectively). There was a significant correlation between the reduction rates of the PV area and those of LA volume (R = 0.411, P < .001). The larger preoperative PV area and greater reduction in LA volume were associated with advanced PV narrowing. Clinical PV stenosis was observed in six PVs, was more common in females (male vs female; 0.8% vs 4.8%, P = .043), and tended to be more frequent in left PVs (left PVs vs right PVs; 3.1% vs 0.6%: P = .107), irrespective of the LA volume reduction. CONCLUSIONS: The significant reduction of the ostial PV area occurred after CBA, which correlated with the reduction rate of LA volume. The narrowing of the PV was partly produced by the LA volume reduction. Clinical PV stenosis was more common in females and tended to be more frequent in left PVs.


Assuntos
Fibrilação Atrial/cirurgia , Criocirurgia/métodos , Átrios do Coração/anatomia & histologia , Átrios do Coração/cirurgia , Veias Pulmonares/anatomia & histologia , Veias Pulmonares/cirurgia , Idoso , Feminino , Humanos , Masculino , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
11.
J Cardiovasc Electrophysiol ; 30(11): 2283-2290, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31471993

RESUMO

INTRODUCTION: Restoration of sinus rhythm (SR) by catheter ablation (CA) of atrial fibrillation (AF) improves exercise tolerance. However, it is still unclear what characteristics of patients are contributing to an improvement in exercise tolerance after CA of AF without heart failure. METHODS AND RESULTS: This study consisted of 51 consecutive patients with persistent or long-standing persistent AF without heart failure who were restored to SR for over 6 months by a successful CA. Exercise tolerance was evaluated by cardiopulmonary exercise testing before and 3 and 6 months after CA. The clinical characteristics contributing to an improvement in exercise tolerance was elucidated. The peak oxygen uptake (VO2 )% significantly increased from 101.4 ± 20.3% to 110.9 ± 19.9% 3 months after the CA (P < .001). The improvement rate in the peak VO2 % exhibited a positive correlation to the baseline brain natriuretic peptide (BNP; ρ = 0.39, P < .01), but not to the age, AF duration, left ventricular ejection fraction, or left atrial size. The linear regression analysis revealed that the baseline BNP was an independent predictor of an improvement in the peak VO2 % (coefficients = 0.32; 95% confidence interval = 0.08, 0.54; P = .01). The peak VO2 % improved significantly in the patients whose baseline BNP level was greater than 100 pg/mL, compared to the others (P < .01). These favorable findings were also observed 6 months after the CA. CONCLUSION: Elimination of persistent AF by CA was associated with an improvement in exercise tolerance. This was particularly true in patients with high BNP values at baseline.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Tolerância ao Exercício , Peptídeo Natriurético Encefálico/sangue , Potenciais de Ação , Idoso , Fibrilação Atrial/sangue , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Biomarcadores/sangue , Ablação por Cateter/efeitos adversos , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Consumo de Oxigênio , Recuperação de Função Fisiológica , Fatores de Tempo , Resultado do Tratamento
12.
Pacing Clin Electrophysiol ; 42(6): 617-624, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30779354

RESUMO

BACKGROUND: Epicardiac conduction via the vein of Marshall (VOM) can bypass the mitral isthmus (MI) line, making MI ablation difficult. This study aimed to assess the contribution of the VOM in achieving MI conduction block. METHODS: This study included 143 consecutive patients with nonparoxysmal atrial fibrillation who underwent initial MI ablation. They were retrospectively classified into two groups, a VOM-guided group (n = 28) and a conventional group (n = 115), according to the use of a 2-Fr electrode catheter inserted in the VOM. The acute success rate of achieving MI block and the ablation data were assessed. When the bidirectional block was verified exclusively in the VOM or coronary sinus (CS) electrodes, we defined it as a pseudo MI block. In the VOM-guided group, we ascertained the complete MI block, verified both in the VOM and CS electrodes. RESULTS: In the VOM-guided group, the pseudoblock was observed in 33.3% of the patients during MI ablation. With significantly less radiofrequency energy (19 322.6 ± 11 352.8 vs 25 389.3 ± 19 951.9, P = 0.04), we achieved a similar level of success rate in MI ablation in the VOM-guided group (96.4% vs 91.3%, P = 0.36). Notably, after achieving complete MI block, atrial burst pacing induced two perimitral flutters in the VOM-guided group, which were successfully terminated by the additional radiofrequency application. CONCLUSIONS: Assessment of electrical conduction through the VOM could clarify the existence of a pseudo MI conduction block. However, the existence of a slow conduction through the MI could be detected only after induction of perimitral atrial tachycardia with atrial programmed stimulation.


Assuntos
Fibrilação Atrial/cirurgia , Vasos Coronários/cirurgia , Sistema de Condução Cardíaco/cirurgia , Valva Mitral/cirurgia , Ablação por Radiofrequência/métodos , Fibrilação Atrial/fisiopatologia , Cateterismo Cardíaco , Angiografia Coronária , Feminino , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/fisiopatologia , Estudos Retrospectivos
13.
Heart Lung Circ ; 28(7): 1050-1058, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31178023

RESUMO

BACKGROUND: A lower cut-off of the oesophageal temperature (ET) during catheter ablation of atrial fibrillation (AF) should be safer, but its durability may become in question. We evaluated an ET cut-off of 38°C with an output of 25W on the posterior wall. METHODS: In 636 consecutive patients (age: 60±10years, male: 542, paroxysmal AF: 405, CHADS2 score: 0.7±0.9), an ET probe was utilised in 303 patients (259 pulmonary vein isolations [PVIs] and 44 simultaneous isolations of the posterior wall and all PVs box isolations [BOXIs]). When the ET increased to >38°C, the radiofrequency delivery was switched off and the ablation point was tagged as an "EsoTag" by the CARTO™ system (Biosense Webster, Irvine, CA, USA). We analysed the characteristics of the ablation lesions at the EsoTags with respect to the dormant conduction, gaps in the redo-session, and ablation outcome. RESULTS: EsoTags were identified in 94.6% of the left PVIs and all BOXIs, and dormant conduction at the EsoTags was identified in 12.0% and 6.8%, respectively. In 10,796 ablation points, the ablation at the EsoTags that were associated with dormant conduction had a significantly shorter duration, smaller force-time integral, and smaller Δimpedance. The duration of an ET of >38°C was significantly and positively correlated with the body mass index and negatively with the left atrial appendage flow velocity. During the redo-sessions in a 10.5±6.0months of follow-up (PVI: 14.7%, BOXI: 11.4%), reconnections at the EsoTags with dormant conduction were observed only in two patients after the PVI. The AF survival rate did not significantly differ in the presence of dormant conduction at the EsoTags (83.1% vs. 75.0%, p=0.696). There were no patients hospitalised for gastroparesis. CONCLUSIONS: Atrial fibrillation ablation utilising an oesophageal temperature cut-off of 38°C might be safe and durable.


Assuntos
Fibrilação Atrial , Temperatura Corporal , Ablação por Cateter , Esôfago/fisiopatologia , Idoso , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
14.
Pacing Clin Electrophysiol ; 40(7): 904-907, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28185283

RESUMO

The subcutaneous implantable cardioverter-defibrillator (S-ICD) is a useful option for patients with a single ventricle (SV) in which transvenous leads are contraindicated because of intracardiac shunts. We report a case in which a right parasternal lead placement was indicated for an S-ICD in a resuscitated patient with an SV. There were significant changes in the magnitude of R to T waves ratio in the right compared to the left parasternal lead position. Screening in the right parasternal position is effective for selecting appropriate patients with congenital heart disease for S-ICD implantations.


Assuntos
Desfibriladores Implantáveis , Eletrocardiografia , Cardiopatias Congênitas/fisiopatologia , Cardiopatias Congênitas/terapia , Ventrículos do Coração/anormalidades , Humanos , Masculino , Pessoa de Meia-Idade
15.
Heart Vessels ; 32(3): 317-325, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27385021

RESUMO

Differences in the methodologies for evaluating atrial fibrillation (AF) ablation outcomes should be evaluated. In the present study, we compared the AF ablation outcomes among periodic clinic electrocardiography (ECG), 24-h Holter ECG, and telemonitoring ECG to evaluate the differences among these methods. In addition, we evaluated the AF-free survival rate for each method with different durations of the blanking period. A total of 30 AF patients were followed up for 6 months after initial catheter ablation, with clinic ECG on every clinic visit, monthly 24-h Holter ECG, and telemonitoring ECG twice daily and upon symptoms. AF relapse was defined as AF or atrial tachycardia detected with any of the methods. Two patients dropped out of the study, and 28 patients were followed up for 8.8 ± 2.7 months. Patients underwent 3.6 ± 0.8 clinic ECG, 5.1 ± 0.8 Holter ECG, and 273 ± 68 telemonitoring ECG examinations. During the first, second, third, fourth, fifth, and sixth months of follow-up, Holter ECG detected relapses in 11.1, 8.3, 11.5, 15.4, 4.2, and 4.8 % of patients and telemonitoring ECG detected relapses in 32.1, 25.0, 25.0, 17.9, 28.6, and 17.9 % of patients, respectively. When no duration was set for the blanking period, the AF-free survival rate was significantly lower with telemonitoring ECG (46.4 %) than with Holter ECG (78.6 %, P = 0.013) or clinic ECG (85.7 %, P = 0.002). In addition, when the duration of the blanking period was set to 3 months, the AF-free survival rate was significantly lower with telemonitoring ECG than with clinic ECG (92.9 vs. 71.4 %, P = 0.041). The AF ablation outcomes with twice-daily telemonitoring ECG might differ from those with clinic ECG when the duration of the blanking period is 0-3 months. A follow-up based solely on clinic ECG might underestimate AF recurrence.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Eletrocardiografia Ambulatorial/métodos , Idoso , Feminino , Seguimentos , Humanos , Japão , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/cirurgia , Recidiva , Taxa de Sobrevida , Telemedicina , Fatores de Tempo , Resultado do Tratamento
16.
Europace ; 18(2): 294-300, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25825457

RESUMO

AIMS: With the new era of multi-tip radiofrequency or balloon ablation catheters replacing the point-to-point ablation strategy, we aimed to determine the feasibility of a ring-laser catheter ablation technology to electrically isolate the superior vena cava (SVC) by exploring the advantages of the limitless catheter tip size possibly with the photodynamic therapy (PDT)-mediated ablation. METHODS AND RESULTS: We developed a first-generation prototype of a circular-laser-mapping catheter by fitting a 7 cm plastic optical fibre onto a circular variable-loop Lasso™ mapping catheter. Following SVC venography, both the laser catheter and another ring catheter for monitoring the SVC potentials were placed at the SVC. After the systemic infusion of a photosensitizer (talaporfin sodium), we initiated the irradiation with an output of 1 W in three canines and 0.3 W in four. The creation of electrical isolation as well as occurrence of phrenic nerve injury, sinus node injury, and SVC stenosis were evaluated before, immediately after, and 1 month after the procedure. A PDT-mediated SVC isolation was successfully performed in all seven canines. The isolation was completed with a laser irradiation of 70.4 ± 71.4 J/cm under 30.9 ± 5.0 µg/mL of a photosensitizer without any sinus node injury, phrenic nerve palsy, or SVC stenosis in both the acute and chronic evaluations. The minimum isolation time of 270 s was not correlated with the laser input power or the photosensitizer concentration. CONCLUSION: The electrical SVC isolation was successfully and instantly achieved using the PDT laser-ring catheter without any complications.


Assuntos
Ablação por Cateter/métodos , Fotoquimioterapia/métodos , Veia Cava Superior/cirurgia , Potenciais de Ação , Animais , Ablação por Cateter/efeitos adversos , Ablação por Cateter/instrumentação , Catéteres , Cães , Eletrocardiografia , Desenho de Equipamento , Estudos de Viabilidade , Lasers , Modelos Animais , Flebografia , Fotoquimioterapia/efeitos adversos , Fotoquimioterapia/instrumentação , Fármacos Fotossensibilizantes/administração & dosagem , Porfirinas/administração & dosagem , Fatores de Tempo , Veia Cava Superior/diagnóstico por imagem
17.
Europace ; 17(8): 1309-15, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25564546

RESUMO

AIMS: Photodynamic therapy (PDT) is based on non-thermal injury mediated by singlet oxygen species and is used clinically in cancer therapy. In our continuing efforts to apply this technology to cardiac catheter ablation, we clarified the optimal condition for creating PDT-mediated lesions using a laser catheter. METHODS AND RESULTS: In a total of 35 canines, we applied a laser directly to the epicardium of the beating heart during open-chest surgery at 15 min after administration of a photosensitizer, talaporfin sodium. We evaluated the lesion size (depth and width) using hematoxylin-eosin staining under varying conditions as follows: laser output (5, 10, 20 W/cm(2)), irradiation time (0-60 s), photosensitizer concentration (0, 2.5, 5 mg/kg), blood oxygen concentration (103.5 ± 2.1 vs. 548.0 ± 18.4 torr), and contact force applied during irradiations (low: <20 g, high: >20 g). A laser irradiation at 20 W/cm(2) for 60 s under 5 mg/kg (29 µg/mL) of photosensitizer induced a lesion 8.7 ± 0.8 mm deep and 5.2 ± 0.2 mm wide. The lesion size was thus positively correlated to the laser power, irradiation time, and photosensitizer concentration, and was independent of the applied contact force and oxygen concentration. In addition, the concentration of the photosensitizer strongly correlated with the changes in the pulse oximetry data and fluorescence of the backscattering laser, suggesting that a clinically appropriate condition could be estimated in real time. CONCLUSION: Photodynamic therapy-mediated cardiac lesions might be controllable by regulating the photosensitizer concentration, laser output, and irradiation time.


Assuntos
Ablação por Cateter/métodos , Terapia a Laser/métodos , Fotoquimioterapia/métodos , Porfirinas/administração & dosagem , Fibrilação Ventricular/cirurgia , Animais , Terapia Combinada/métodos , Cães , Relação Dose-Resposta a Droga , Fármacos Fotossensibilizantes/administração & dosagem , Resultado do Tratamento , Fibrilação Ventricular/diagnóstico
18.
Europace ; 17(4): 546-51, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25672983

RESUMO

AIMS: The left atrial appendage (LAA) represents the major source of cardiac thrombus formation in patients with atrial fibrillation (AF). Phased-array intracardiac echocardiography (ICE) has become available and frequently used during catheter ablation of AF. We attempted to study the feasibility of using ICE for the visualization and evaluation of the LAA from the pulmonary artery (PA) in patients with AF. METHODS AND RESULTS: Eighty patients with AF undergoing catheter ablation (70 males, 57.5 ± 9.1 years) were included. Transoesophageal echocardiography was performed on the prior day before the catheter ablation, and ICE was performed just before the transseptal puncture during the catheter ablation. The ICE catheter was advanced up into the PA from the femoral vein, where the LAA was clearly and entirely visualized by manipulating the ICE catheter. We compared the degree of spontaneous echo contrast, and the correlation was obtained between the ICE and TEE (κ = 0.534, P < 0.001). Furthermore, the LAA flow velocity (LAA emptying and filling velocities) measured by ICE had a good correlation to that measured by TEE (R = 0.872, P < 0.01 and R = 0.753, P < 0.01, respectively). No patients developed any complications. CONCLUSION: The utilization of ICE in the PA is feasible for the observation and evaluation of the LAA.


Assuntos
Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/diagnóstico por imagem , Ecocardiografia/métodos , Endossonografia/métodos , Artéria Pulmonar/diagnóstico por imagem , Trombose/diagnóstico por imagem , Fibrilação Atrial/complicações , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Trombose/etiologia
19.
Circulation ; 128(10): 1048-54, 2013 Sep 03.
Artigo em Inglês | MEDLINE | ID: mdl-23902757

RESUMO

BACKGROUND: The characteristic ECG of Brugada syndrome (BS) can be masked by complete right bundle-branch block (CRBBB) and exposed by resolution of the block or pharmacological or pacing maneuvers. METHODS AND RESULTS: The study consisted of 11 patients who had BS and CRBBB. BS was diagnosed before the development of CRBBB, on the resolution of CRBBB, or from new characteristic ST-segment changes that could be attributable to BS. Structural heart diseases were excluded, and coronary spasm was excluded on the basis of a provocation test at catheterization. In 7 patients, BS was diagnosed before the development of CRBBB. BS was diagnosed when CRBBB resolved spontaneously (n=1) or by right ventricular pacing (n=3). The precipitating cause for the spontaneous resolution of CRBBB, however, was not apparent. On repeated ECGs, new additional upward-convex ST-segment elevation was found in V2 or V3 in 3 patients. In 2 patients, new ST-segment elevation was induced by class IC drugs. The QRS duration was more prolonged in patients with BS and CRBBB compared with age- and sex-matched controls: 170±13 versus 145±15 milliseconds in V1 and 144±19 versus 128±7 milliseconds in V5 (both P<0.0001). The amplitude of R in V1 was smaller [corrected] in the BS patients than in the control subjects (P=0.0323), but that of R' was similar (P=0.0560). CONCLUSIONS: BS can coexist behind CRBBB, and CRBBB can completely mask BS. BS might be demonstrated by relief of CRBBB or by spontaneous or drug-induced ST-segment elevation. The prevalence, mechanism, and clinical significance of a combination of CRBBB and BS are yet to be determined.


Assuntos
Síndrome de Brugada/diagnóstico , Síndrome de Brugada/fisiopatologia , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/fisiopatologia , Adulto , Idoso , Eletrocardiografia/métodos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
20.
J Cardiovasc Electrophysiol ; 25(1): 16-22, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24103056

RESUMO

BACKGROUND: Although the superior vena cava (SVC) has been well known to be one of the important foci triggering atrial fibrillation (AF), its electrophysiological characteristics have received little research attention. The aim of this study was to investigate the electrophysiological properties of the SVC and venoatrial junction (VAJ). METHODS: Twenty-five consecutive AF patients without structural heart disease undergoing electrical SVC isolation were included in this study. After pulmonary vein isolation, a circular decapolar catheter and 2 multipolar catheters were emplaced in the VAJ, right atrial appendage (RAA), and SVC, respectively. Burst pacing and single extrastimulus were applied from the RAA and SVC. The atrial and caval potentials on the circular catheter in the VAJ were investigated. RESULTS: Intracaval conduction delay and various degrees of conduction block over the VAJ were observed with burst pacing from both the RAA and SVC. A single extrastimulus from the RAA and SVC with a basic cycle length of 600 milliseconds prolonged the conduction time via the VAJ by 81 ± 49.7 milliseconds and 61 ± 58.7 milliseconds, respectively. The atrial and caval electrograms at the VAJ, which were separated from each other by pacing applications, facilitated mapping of the earliest activation site at the VAJ. CONCLUSIONS: Intracaval conduction delay and decremental conduction property via the VAJ were demonstrated using pacing maneuvers. Pacing applications from the RAA or SVC can help distinguish the atrial and caval potentials and can facilitate mapping of the optimal ablation sites to isolate the SVC.


Assuntos
Fibrilação Atrial/fisiopatologia , Ablação por Cateter/métodos , Átrios do Coração/fisiopatologia , Veias Pulmonares/fisiopatologia , Veia Cava Superior/fisiopatologia , Idoso , Fibrilação Atrial/cirurgia , Eletrocardiografia/métodos , Feminino , Seguimentos , Átrios do Coração/anormalidades , Átrios do Coração/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/anormalidades , Veias Pulmonares/cirurgia , Resultado do Tratamento , Veia Cava Superior/anormalidades , Veia Cava Superior/cirurgia
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa