Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 152
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Nucl Cardiol ; 30(6): 2427-2437, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37221409

RESUMO

BACKGROUND: The aim of this research was to asses perfusion-defect detection-accuracy by human observers as a function of reduced-counts for 3D Gaussian post-reconstruction filtering vs deep learning (DL) denoising to determine if there was improved performance with DL. METHODS: SPECT projection data of 156 normally interpreted patients were used for these studies. Half were altered to include hybrid perfusion defects with defect presence and location known. Ordered-subset expectation-maximization (OSEM) reconstruction was employed with the optional correction of attenuation (AC) and scatter (SC) in addition to distance-dependent resolution (RC). Count levels varied from full-counts (100%) to 6.25% of full-counts. The denoising strategies were previously optimized for defect detection using total perfusion deficit (TPD). Four medical physicist (PhD) and six physician (MD) observers rated the slices using a graphical user interface. Observer ratings were analyzed using the LABMRMC multi-reader, multi-case receiver-operating-characteristic (ROC) software to calculate and compare statistically the area-under-the-ROC-curves (AUCs). RESULTS: For the same count-level no statistically significant increase in AUCs for DL over Gaussian denoising was determined when counts were reduced to either the 25% or 12.5% of full-counts. The average AUC for full-count OSEM with solely RC and Gaussian filtering was lower than for the strategies with AC and SC, except for a reduction to 6.25% of full-counts, thus verifying the utility of employing AC and SC with RC. CONCLUSION: We did not find any indication that at the dose levels investigated and with the DL network employed, that DL denoising was superior in AUC to optimized 3D post-reconstruction Gaussian filtering.


Assuntos
Aprendizado Profundo , Imagem de Perfusão do Miocárdio , Humanos , Imagem de Perfusão do Miocárdio/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Coração , Curva ROC , Imagens de Fantasmas , Processamento de Imagem Assistida por Computador/métodos
2.
J Nucl Cardiol ; 29(5): 2340-2349, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34282538

RESUMO

BACKGROUND: We previously developed a deep-learning (DL) network for image denoising in SPECT-myocardial perfusion imaging (MPI). Here we investigate whether this DL network can be utilized for improving detection of perfusion defects in standard-dose clinical acquisitions. METHODS: To quantify perfusion-defect detection accuracy, we conducted a receiver-operating characteristic (ROC) analysis on reconstructed images with and without processing by the DL network using a set of clinical SPECT-MPI data from 190 subjects. For perfusion-defect detection hybrid studies were used as ground truth, which were created from clinically normal studies with simulated realistic lesions inserted. We considered ordered-subset expectation-maximization (OSEM) reconstruction with corrections for attenuation, resolution, and scatter and with 3D Gaussian post-filtering. Total perfusion deficit (TPD) scores, computed by Quantitative Perfusion SPECT (QPS) software, were used to evaluate the reconstructed images. RESULTS: Compared to reconstruction with optimal Gaussian post-filtering (sigma = 1.2 voxels), further DL denoising increased the area under the ROC curve (AUC) from 0.80 to 0.88 (P-value < 10-4). For reconstruction with less Gaussian post-filtering (sigma = 0.8 voxels), thus better spatial resolution, DL denoising increased the AUC value from 0.78 to 0.86 (P-value < 10-4) and achieved better spatial resolution in reconstruction. CONCLUSIONS: DL denoising can effectively improve the detection of abnormal defects in standard-dose SPECT-MPI images over conventional reconstruction.


Assuntos
Aprendizado Profundo , Imagem de Perfusão do Miocárdio , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imagem de Perfusão do Miocárdio/métodos , Perfusão , Curva ROC , Tomografia Computadorizada de Emissão de Fóton Único/métodos
3.
J Nucl Cardiol ; 29(6): 3379-3391, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35474443

RESUMO

It has been proved feasible to generate attenuation maps (µ-maps) from cardiac SPECT using deep learning. However, this assumed that the training and testing datasets were acquired using the same scanner, tracer, and protocol. We investigated a robust generation of CT-derived µ-maps from cardiac SPECT acquired by different scanners, tracers, and protocols from the training data. We first pre-trained a network using 120 studies injected with 99mTc-tetrofosmin acquired from a GE 850 SPECT/CT with 360-degree gantry rotation, which was then fine-tuned and tested using 80 studies injected with 99mTc-sestamibi acquired from a Philips BrightView SPECT/CT with 180-degree gantry rotation. The error between ground-truth and predicted µ-maps by transfer learning was 5.13 ± 7.02%, as compared to 8.24 ± 5.01% by direct transition without fine-tuning and 6.45 ± 5.75% by limited-sample training. The error between ground-truth and reconstructed images with predicted µ-maps by transfer learning was 1.11 ± 1.57%, as compared to 1.72 ± 1.63% by direct transition and 1.68 ± 1.21% by limited-sample training. It is feasible to apply a network pre-trained by a large amount of data from one scanner to data acquired by another scanner using different tracers and protocols, with proper transfer learning.


Assuntos
Compostos Radiofarmacêuticos , Tecnécio Tc 99m Sestamibi , Humanos , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único , Aprendizado de Máquina , Tomografia Computadorizada de Emissão de Fóton Único/métodos
4.
Eur J Nucl Med Mol Imaging ; 48(11): 3457-3468, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-33797598

RESUMO

PURPOSE: Reconstructed transaxial cardiac SPECT images need to be reoriented into standard short-axis slices for subsequent accurate processing and analysis. We proposed a novel deep-learning-based method for fully automatic reorientation of cardiac SPECT images and evaluated its performance on data from two clinical centers. METHODS: We used a convolutional neural network to predict the 6 rigid-body transformation parameters and a spatial transformation network was then implemented to apply these parameters on the input images for image reorientation. A novel compound loss function which balanced the parametric similarity and penalized discrepancy of the prediction and training dataset was utilized in the training stage. Data from a set of 322 patients underwent data augmentation to 6440 groups of images for the network training, and a dataset of 52 patients from the same center and 23 patients from another center were used for evaluation. Similarity of the 6 parameters was analyzed between the proposed and the manual methods. Polar maps were generated from the output images and the averaged count values of the 17 segments were computed from polar maps to evaluate the quantitative accuracy of the proposed method. RESULTS: All the testing patients achieved automatic reorientation successfully. Linear regression results showed the 6 predicted rigid parameters and the average count value of the 17 segments having good agreement with the reference manual method. No significant difference by paired t-test was noticed between the rigid parameters of our method and the manual method (p > 0.05). Average count values of the 17 segments show a smaller difference of the proposed and manual methods than those between the existing and manual methods. CONCLUSION: The results strongly indicate the feasibility of our method in accurate automatic cardiac SPECT reorientation. This deep-learning-based reorientation method has great promise for clinical application and warrants further investigation.


Assuntos
Aprendizado Profundo , Humanos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Redes Neurais de Computação , Tomografia Computadorizada de Emissão de Fóton Único
5.
J Nucl Cardiol ; 28(2): 624-637, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-31077073

RESUMO

BACKGROUND: In the ongoing efforts to reduce cardiac perfusion dose (injected radioactivity) for conventional SPECT/CT systems, we performed a human observer study to confirm our clinical model observer findings that iterative reconstruction employing OSEM (ordered-subset expectation-maximization) at 25% of the full dose (quarter-dose) has a similar performance for detection of hybrid cardiac perfusion defects as FBP at full dose. METHODS: One hundred and sixty-six patients, who underwent routine rest-stress Tc-99m sestamibi cardiac perfusion SPECT/CT imaging and clinically read as normally perfused, were included in the study. Ground truth was established by the normal read and the insertion of hybrid defects. In addition to the reconstruction of the 25% of full-dose data using OSEM with attenuation (AC), scatter (SC), and spatial resolution correction (RC), FBP and OSEM (with AC, SC, and RC) both at full dose (100%) were done. Both human observer and clinical model observer confidence scores were obtained to generate receiver operating characteristics (ROC) curves in a task-based image quality assessment. RESULTS: Average human observer AUC (area under the ROC curve) values of 0.725, 0.876, and 0.890 were obtained for FBP at full dose, OSEM at 25% of full dose, and OSEM at full dose, respectively. Both OSEM strategies were significantly better than FBP with P values of 0.003 and 0.01 respectively, while no significant difference was recorded between OSEM methods (P = 0.48). The clinical model observer results were 0.791, 0.822, and 0.879, respectively, for the same patient cases and processing strategies used in the human observer study. CONCLUSIONS: Cardiac perfusion SPECT/CT using OSEM reconstruction at 25% of full dose has AUCs larger than FBP and closer to those of full-dose OSEM when read by human observers, potentially replacing the higher dose studies during clinical reading.


Assuntos
Imagem de Perfusão do Miocárdio/métodos , Compostos Radiofarmacêuticos , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tecnécio Tc 99m Sestamibi , Adulto , Idoso , Idoso de 80 Anos ou mais , Fracionamento da Dose de Radiação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Curva ROC , Estudos Retrospectivos , Adulto Jovem
6.
J Nucl Cardiol ; 27(1): 80-95, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-28432671

RESUMO

BACKGROUND: Respiratory motion can deteriorate image fidelity in cardiac perfusion SPECT. We determined the extent of respiratory motion, assessed its impact on image fidelity, and investigated the existence of gender differences, thereby examining the influence of respiratory motion in a large population of patients. METHODS: One thousand one hundred and three SPECT/CT patients underwent visual tracking of markers on their anterior surface during stress acquisition to track respiratory motion. The extent of motion was estimated by registration. Visual indicators of changes in cardiac slices with motion correction, and the correlation between the extent of motion with changes in segmental-counts were assessed. RESULTS: Respiratory motion in the head-to-feet direction was the largest component of motion, varying between 1.1 and 37.4 mm, and was statistically significantly higher (p = 0.002) for males than females. In 33.0% of the patients, motion estimates were larger than 10 mm. Patients progressively show more distinct visual changes with an increase in the extent of motion. The increase in segmental-count differences in the anterior, antero-lateral, and inferior segments correlated with the extent of motion. CONCLUSIONS: Respiratory motion correction diminished the artefactual reduction in anterior and inferior wall counts associated with respiratory motion. The extent of improvement was strongly related to the magnitude of motion.


Assuntos
Artefatos , Cardiopatias/diagnóstico por imagem , Imagem de Perfusão do Miocárdio , Mecânica Respiratória/fisiologia , Tomografia Computadorizada de Emissão de Fóton Único , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Cardiopatias/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Movimento (Física) , Compostos Radiofarmacêuticos , Fatores Sexuais , Tecnécio Tc 99m Sestamibi , Adulto Jovem
7.
J Nucl Cardiol ; 27(2): 634-647, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-30088195

RESUMO

BACKGROUND: Respiratory gating reduces motion blurring in cardiac SPECT. Here we aim to evaluate the performance of three respiratory gating strategies using a population of digital phantoms with known truth and clinical data. METHODS: We analytically simulated 60 projections for 10 XCAT phantoms with 99mTc-sestamibi distributions using three gating schemes: equal amplitude gating (AG), equal count gating (CG), and equal time gating (TG). Clinical list-mode data for 10 patients who underwent 99mTc-sestamibi scans were also processed using the 3 gating schemes. Reconstructed images in each gate were registered to a reference gate, averaged and reoriented to generate the polar plots. For simulations, image noise, relative difference (RD) of averaged count for each of the 17 segment, and relative defect size difference (RSD) were analyzed. For clinical data, image intensity profile and FWHM were measured across the left ventricle wall. RESULTS: For simulations, AG and CG methods showed significantly lower RD and RSD compared to TG, while noise variation was more non-uniform through different gates for AG. In the clinical study, AG and CG had smaller FWHM than TG. CONCLUSIONS: AG and CG methods show better performance for motion reduction and are recommended for clinical respiratory gating SPECT implementation.


Assuntos
Coração/diagnóstico por imagem , Respiração , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Artefatos , Simulação por Computador , Feminino , Ventrículos do Coração/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Movimento (Física) , Imagens de Fantasmas , Reprodutibilidade dos Testes , Técnicas de Imagem de Sincronização Respiratória/métodos , Tecnécio Tc 99m Sestamibi
8.
J Nucl Cardiol ; 27(2): 562-572, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-30406608

RESUMO

BACKGROUND: We previously optimized several reconstruction strategies in SPECT myocardial perfusion imaging (MPI) with low dose for perfusion-defect detection. Here we investigate whether reducing the administered activity can also maintain the diagnostic accuracy in evaluating cardiac function. METHODS: We quantified the myocardial motion in cardiac-gated stress 99m-Tc-sestamibi SPECT studies from 163 subjects acquired with full dose (29.8 ± 3.6 mCi), and evaluated the agreement of the obtained motion/thickening and ejection fraction (EF) measures at various reduced dose levels (uniform reduction or personalized dose) with that at full dose. We also quantified the detectability of abnormal motion via a receiver-operating characteristics (ROC) study. For reconstruction we considered both filtered backprojection (FBP) without correction for degradations, and iterative ordered-subsets expectation-maximization (OS-EM) with resolution, attenuation and scatter corrections. RESULTS: With dose level lowered to 25% of full dose, the obtained results on motion/thickening, EF and abnormal motion detection were statistically comparable to full dose in both reconstruction strategies, with Pearson's r > 0.9 for global motion measures between low dose and full dose. CONCLUSIONS: The administered activity could be reduced to 25% of full dose without degrading the function assessment performance. Low dose reconstruction optimized for perfusion-defect detection can be reasonable for function assessment in gated SPECT.


Assuntos
Coração/diagnóstico por imagem , Imagem de Perfusão do Miocárdio/métodos , Tecnécio Tc 99m Sestamibi , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Idoso , Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Feminino , Ventrículos do Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Movimento (Física) , Perfusão , Curva ROC , Reprodutibilidade dos Testes , Espalhamento de Radiação , Tomografia Computadorizada por Raios X
9.
J Nucl Cardiol ; 26(5): 1526-1538, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30062470

RESUMO

BACKGROUND: In cardiac SPECT perfusion imaging, respiratory motion can cause non-uniform blurring in the reconstructed myocardium. We investigate the potential benefit of respiratory correction with respiratory-binned acquisitions, both at standard dose and at reduced dose, for defect detection and for left ventricular (LV) wall resolution. METHODS: We applied two reconstruction methods for respiratory motion correction: post-reconstruction motion correction (PMC) and motion-compensated reconstruction (MCR), and compared with reconstruction without motion correction (Non-MC). We quantified the presence of perfusion defects in reconstructed images by using the total perfusion deficit (TPD) scores and conducted receiver-operating-characteristic (ROC) studies using TPD. We quantified the LV spatial resolution by using the FWHM of its cross-sectional intensity profile. RESULTS: The values in the area-under-the-ROC-curve (AUC) achieved by MCR, PMC, and Non-MC at standard dose were 0.835, 0.830, and 0.798, respectively. Similar AUC improvements were also obtained by MCR and PMC over Non-MC at 50%, 25%, and 12.5% of full dose. Improvements in LV resolution were also observed with motion correction. CONCLUSIONS: Respiratory-binned acquisitions can improve perfusion-defect detection accuracy over traditional reconstruction both at standard dose and at reduced dose. Motion correction may contribute to achieving further dose reduction while maintaining the diagnostic accuracy of traditional acquisitions.


Assuntos
Ventrículos do Coração/diagnóstico por imagem , Coração/diagnóstico por imagem , Movimento , Tomografia Computadorizada de Emissão de Fóton Único , Adulto , Idoso , Área Sob a Curva , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Miocárdio/patologia , Perfusão , Imagens de Fantasmas , Curva ROC , Doses de Radiação , Reprodutibilidade dos Testes , Respiração
10.
J Nucl Cardiol ; 25(6): 2117-2128, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-28537039

RESUMO

BACKGROUND: We investigated the extent to which the administered dose (activity) level can be reduced without sacrificing diagnostic accuracy for three reconstruction strategies for SPECT-myocardial perfusion imaging (MPI). METHODS: We optimized the parameters of the three reconstruction strategies for perfusion-defect detection over a range of simulated administered dose levels using a set of hybrid studies (derived from 190 subjects) consisting of clinical SPECT-MPI data modified to contain realistic simulated lesions. The optimized strategies we considered are filtered backprojection (FBP) with no correction for degradations, ordered-subsets expectation-maximization (OS-EM) with attenuation correction (AC), scatter correction (SC), and resolution correction (RC), and OS-EM with scatter and resolution correction only. Each study was evaluated using a total perfusion deficit (TPD) score computed by the Quantitative Perfusion SPECT (QPS) software package. We conducted a receiver operating characteristics (ROC) study based on the TPD scores for each dose level and reconstruction strategy. RESULTS: For FBP, the achieved optimum values of the area under the ROC curve (AUC) at 100%, 50%, 25%, and 12.5% of standard dose were 0.75, 0.74, 0.72, and 0.70, respectively, compared to 0.81, 0.79, 0.76, and 0.74 for OS-EM with AC-SC-RC and 0.78, 0.77, 0.74, 0.72 for OS-EM with SC-RC. CONCLUSIONS: Our results suggest that studies reconstructed by OS-EM with AC-SC-RC could possibly be reduced, on average, to 25% of the originally administered dose without causing diagnostic accuracy (AUC) to decrease below that of FBP.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imagem de Perfusão do Miocárdio/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação
11.
Surg Radiol Anat ; 39(10): 1149-1159, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28286911

RESUMO

PURPOSE: The hippocampus has a critical role in many common disease processes. Currently, routine 3 Tesla structural MRI is a mainstay of clinical diagnosis. The goal of our study is to evaluate the normal variability in size and/or conspicuity of the hippocampal subcomponents in routine clinical 3 Tesla high-resolution T2-weighted images to provide a basis for better defining pathological derangements. Additionally, we utilize diffusion data acquired from a 17.6 Tesla MRI of the hippocampus as a benchmark to better illustrate these subcomponents. METHODS: The hippocampus was retrospectively assessed on 104 clinically normal patients undergoing coronal T2-weighted imaging. The conspicuity of the majority of hippocampal subcomponents was assessed in each portion of the hippocampus. Additionally, easily applicable cross-sectional measurements and signal intensities were obtained to evaluate the range of normal, as well as inter- and intra-subject variability. RESULTS: The normal range of cross-sectional measurements of the hippocampal subcomponents was calculated. There was minimal side-to-side variability in cross-sectional measurements of hippocampal subcomponents (< 5%) with the exception of the subiculum (R>L by 8.3%) and the CA4/DG (R>L by 5.8%). The internal architecture showed high variability in visibility of subcomponents between different segments of the hippocampus. CONCLUSIONS: Confident clinical assessment of the hippocampus requires a thorough knowledge of hippocampal size and signal, but also the internal architecture expected to be seen. The data provided in this study will provide the reader with vital information necessary for distinguishing a normal from abnormal exam.


Assuntos
Hipocampo/anatomia & histologia , Imageamento por Ressonância Magnética/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valores de Referência , Estudos Retrospectivos
12.
IEEE Trans Nucl Sci ; 63(3): 1419-1425, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28042170

RESUMO

We have recently been successful in the development and testing of rigid-body motion tracking, estimation and compensation for cardiac perfusion SPECT based on a visual tracking system (VTS). The goal of this study was to evaluate in patients the effectiveness of our rigid-body motion compensation strategy. Sixty-four patient volunteers were asked to remain motionless or execute some predefined body motion during an additional second stress perfusion acquisition. Acquisitions were performed using the standard clinical protocol with 64 projections acquired through 180 degrees. All data were reconstructed with an ordered-subsets expectation-maximization (OSEM) algorithm using 4 projections per subset and 5 iterations. All physical degradation factors were addressed (attenuation, scatter, and distance dependent resolution), while a 3-dimensional Gaussian rotator was used during reconstruction to correct for six-degree-of-freedom (6-DOF) rigid-body motion estimated by the VTS. Polar map quantification was employed to evaluate compensation techniques. In 54.7% of the uncorrected second stress studies there was a statistically significant difference in the polar maps, and in 45.3% this made a difference in the interpretation of segmental perfusion. Motion correction reduced the impact of motion such that with it 32.8 % of the polar maps were statistically significantly different, and in 14.1% this difference changed the interpretation of segmental perfusion. The improvement shown in polar map quantitation translated to visually improved uniformity of the SPECT slices.

13.
IEEE Trans Nucl Sci ; 63(1): 90-97, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27182078

RESUMO

For the 2011 FDA approved Parkinson's Disease (PD) SPECT imaging agent I-123 labeled DaTscan, the volume of interest (VOI) is the interior portion of the brain. However imaging of the occipital lobe is also required with PD for calculation of the striatal binding ratio (SBR), a parameter of significance in early diagnosis, differentiation of PD from other disorders with similar clinical presentations, and monitoring progression. Thus we propose the usage of a combination of a multi-pinhole (MPH) collimator on one head of the SPECT system and a fan-beam on the other. The MPH would be designed to provide high resolution and sensitivity for imaging of the interior portion of the brain. The fan-beam collimator would provide lower resolution but complete sampling of the brain addressing data sufficiency and allowing a volume-of-interest to be defined over the occipital lobe for calculation of SBR's. Herein we focus on the design of the MPH component of the combined system. Combined reconstruction will be addressed in a subsequent publication. An analysis of 46 clinical DaTscan studies was performed to provide information to define the VOI, and design of a MPH collimator to image this VOI. The system spatial resolution for the MPH was set to 4.7 mm, which is comparable to that of clinical PET systems, and significantly smaller than that of fan-beam collimators employed in SPECT. With this set, we compared system sensitivities for three aperture array designs, and selected the 3 × 3 array due to it being the highest of the three. The combined sensitivity of the apertures for it was similar to that of an ultra-high resolution fan-beam (LEUHRF) collimator, but smaller than that of a high-resolution fan-beam collimator (LEHRF). On the basis of these results we propose the further exploration of this design through simulations, and the development of combined MPH and fan-beam reconstruction.

14.
IEEE Trans Nucl Sci ; 63(1): 117-129, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27182079

RESUMO

The objectives of this investigation were to model the respiratory motion of solitary pulmonary nodules (SPN) and then use this model to determine the impact of respiratory motion on the localization and detection of small SPN in SPECT imaging for four reconstruction strategies. The respiratory motion of SPN was based on that of normal anatomic structures in the lungs determined from breath-held CT images of a volunteer acquired at two different stages of respiration. End-expiration (EE) and time-averaged (Frame Av) non-uniform-B-spline cardiac torso (NCAT) digital-anthropomorphic phantoms were created using this information for respiratory motion within the lungs. SPN were represented as 1 cm diameter spheres which underwent linear motion during respiration between the EE and end-inspiration (EI) time points. The SIMIND Monte Carlo program was used to produce SPECT projection data simulating Tc-99m depreotide (NeoTect) imaging. The projections were reconstructed using 1) no correction (NC), 2) attenuation correction (AC), 3) resolution compensation (RC), and 4) attenuation correction, scatter correction, and resolution compensation (AC_SC_RC). A human-observer localization receiver operating characteristics (LROC) study was then performed to determine the difference in localization and detection accuracy with and without the presence of respiratory motion. The LROC comparison determined that respiratory motion degrades tumor detection for all four reconstruction strategies, thus correction for SPN motion would be expected to improve detection accuracy. The inclusion of RC in reconstruction improved detection accuracy for both EE and Frame Av over NC and AC. Also the magnitude of the impact of motion was least for AC_SC_RC.

15.
IEEE Trans Nucl Sci ; 63(1): 130-139, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27182080

RESUMO

The objective of this investigation was to determine the effectiveness of three motion reducing strategies in diminishing the degrading impact of respiratory motion on the detection of small solitary pulmonary nodules (SPN) in single photon emission computed tomographic (SPECT) imaging in comparison to a standard clinical acquisition and the ideal case of imaging in the absence of respiratory motion. To do this non-uniform rational B-spline cardiac-torso (NCAT) phantoms based on human-volunteer CT studies were generated spanning the respiratory cycle for a normal background distribution of Tc-99m NeoTect. Similarly, spherical phantoms of 1.0 cm diameter were generated to model small SPN for each of 150 uniquely located sites within the lungs whose respiratory motion was based on the motion of normal structures in the volunteer CT studies. The SIMIND Monte Carlo program was used to produce SPECT projection data from these. Normal and single-lesion containing SPECT projection sets with a clinically realistic Poisson noise level were created for the cases of: 1) the end-expiration (EE) frame with all counts, 2) respiration-averaged motion with all counts, 3) one-fourth of the 32 frames centered around EE (Quarter-Binning), 4) one-half of the 32 frames centered around EE (Half-Binning), and 5) eight temporally binned frames spanning the respiratory cycle. Each of the sets of combined projection data were reconstructed with RBI-EM with system spatial-resolution compensation (RC). Based on the known motion for each of the 150 different lesions, the reconstructed volumes of respiratory bins were shifted so as to superimpose the locations of the SPN onto that in the first bin (Reconstruct and Shift). Five human-observers performed localization receiver operating characteristics (LROC) studies of SPN detection. The observer results were analyzed for statistical significance differences in SPN detection accuracy among the three correction strategies, the standard acquisition, and the ideal case of the absence of respiratory motion. Our human-observer LROC determined that Quarter-Binning and Half-Binning strategies resulted in SPN detection accuracy statistically significantly below (P < 0.05) that of standard clinical acquisition, whereas the Reconstruct and Shift strategy resulted in a detection accuracy not statistically significantly different from that of the ideal case. This investigation demonstrates that tumor detection based on acquisitions associated with less than all the counts which could potentially be employed may result in poorer detection despite limiting the motion of the lesion. The Reconstruct and Shift method results in tumor detection that is equivalent to ideal motion correction.

16.
Immunology ; 146(2): 206-16, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25967648

RESUMO

This study tested the hypothesis that peripheral immune challenges will produce predictable activation patterns in the rat brain consistent with sympathetic excitation. As part of examining this hypothesis, this study asked whether central activation is dependent on capsaicin-sensitive C-fibres. We induced skin contact sensitivity immune responses with 2,4-dinitrochlorobenzene (DNCB), in the presence or absence of the acute C-fibre toxin capsaicin (8-methyl-N-vanillyl-6-nonenamide) to trigger immune responses with and without diminished activity of C-fibres. Innovative blood-oxygen-level-dependent functional magnetic resonance imaging data revealed that the skin contact sensitivity immune responses induced with DNCB were associated with localized increases in brain neuronal activity in treated rats. This response was diminished by pre-treatment with capsaicin 1 week before scans. In the same animals, we found expression of the immediate early gene c-Fos in sub-regions of the amygdala and hypothalamic sympathetic brain nuclei. Significant increases in c-Fos expression were found in the supraoptic nucleus, central amygdala and medial habenula following immune challenges. Our results support the idea that selective brain regions, some of which are associated with sympathetic function, process or modulate immune function through pathways that are partially dependent on C-fibres. Together with previous studies demonstrating the motor control pathways from brain to immune targets, these findings indicate a central neuroimmune system to monitor host status and coordinate appropriate host responses.


Assuntos
Dermatite de Contato/imunologia , Hipotálamo/imunologia , Fibras Nervosas Amielínicas/imunologia , Pele/inervação , Animais , Biomarcadores/metabolismo , Mapeamento Encefálico/métodos , Capsaicina/farmacologia , Dermatite de Contato/metabolismo , Dermatite de Contato/fisiopatologia , Dinitroclorobenzeno , Modelos Animais de Doenças , Hipotálamo/efeitos dos fármacos , Hipotálamo/metabolismo , Hipotálamo/fisiopatologia , Imageamento por Ressonância Magnética , Masculino , Fibras Nervosas Amielínicas/efeitos dos fármacos , Fibras Nervosas Amielínicas/metabolismo , Vias Neurais/imunologia , Vias Neurais/metabolismo , Proteínas Proto-Oncogênicas c-fos/metabolismo , Ratos Sprague-Dawley , Sistema Nervoso Simpático/imunologia , Sistema Nervoso Simpático/fisiopatologia , Fatores de Tempo , Regulação para Cima
17.
IEEE Trans Nucl Sci ; 62(4): 1813-1824, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26543244

RESUMO

PURPOSE: We investigate the differences without/with respiratory motion correction in apparent imaging agent localization induced in reconstructed emission images when the attenuation maps used for attenuation correction (from CT) are misaligned with the patient anatomy during emission imaging due to differences in respiratory state. METHODS: We investigated use of attenuation maps acquired at different states of a 2 cm amplitude respiratory cycle (at end-expiration, at end-inspiration, the center map, the average transmission map, and a large breath-hold beyond range of respiration during emission imaging) to correct for attenuation in MLEM reconstruction for several anatomical variants of the NCAT phantom which included both with and without non-rigid motion between heart and sub-diaphragmatic regions (such as liver, kidneys etc). We tested these cases with and without emission motion correction and attenuation map alignment/non-alignment. RESULTS: For the NCAT default male anatomy the false count-reduction due to breathing was largely removed upon emission motion correction for the large majority of the cases. Exceptions (for the default male) were for the cases when using the large-breathhold end-inspiration map (TI_EXT), when we used the end-expiration (TE) map, and to a smaller extent, the end-inspiration map (TI). However moving the attenuation maps rigidly to align the heart region, reduced the remaining count-reduction artifacts. For the female patient count-reduction remained post motion correction using rigid map-alignment due to the breast soft-tissue misalignment. Quantitatively, after the transmission (rigid) alignment correction, the polar-map 17-segment RMS error with respect to the reference (motion-less case) reduced by 46.5% on average for the extreme breathhold case. The reductions were 40.8% for end-expiration map and 31.9% for end-inspiration cases on the average, comparable to the semi-ideal case where each state uses its own attenuation map for correction. CONCLUSIONS: Two main conclusions are that even rigid emission motion correction to rigidly align the heart region to the attenuation map helps in average cases to reduce the count-reduction artifacts and secondly, within the limits of the study (ex. rigid correction) when there is lung tissue inferior to the heart as with the NCAT phantom employed in this study endexpiration maps (TE) might best be avoided as they may create more artifacts than the end-inspiration (TI) maps.

18.
IEEE Trans Nucl Sci ; 61(1): 192-201, 2014 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-24817767

RESUMO

Respiratory motion of the heart impacts the diagnostic accuracy of myocardial-perfusion emission-imaging studies. Amplitude binning has come to be the method of choice for binning list-mode based acquisitions for correction of respiratory motion in PET and SPECT. In some subjects respiratory motion exhibits hysteretic behavior similar to damped non-linear cyclic systems. The detection and correction of hysteresis between the signals from surface movement of the patient's body used in binning and the motion of the heart within the chest remains an open area for investigation. This study reports our investigation in nine volunteers of the combined MRI tracking of the internal respiratory motion of the heart using Navigators with stereo-tracking of markers on the volunteer's chest and abdomen by a visual-tracking system (VTS). The respiratory motion signals from the internal organs and the external markers were evaluated for hysteretic behavior analyzing the temporal correspondence of the signals. In general, a strong, positive correlation between the external marker motion (AP direction) and the internal heart motion (SI direction) during respiration was observed. The average ± standard deviation in the Spearman's ranked correlation coefficient (ρ) over the nine volunteer studied was 0.92 ± 0.1 between the external abdomen marker and the internal heart, and 0.87 ± 0.2 between the external chest marker and the internal heart. However despite the good correlation on average for the nine volunteers, in three studies a poor correlation was observed due to hysteretic behavior between inspiration and expiration for either the chest marker and the internal motion of the heart, or the abdominal marker and the motion of the heart. In all cases we observed a good correlation of at least either the abdomen or the chest with the heart. Based on this result, we propose the use of marker motion from both the chest and abdomen regions when estimating the internal heart motion to detect and address hysteresis when binning list-mode emission data.

19.
J Stroke Cerebrovasc Dis ; 23(5): e355-63, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24582784

RESUMO

Our objective is to develop a new therapy for the treatment of stroke. Currently, the only effective therapy for acute ischemic stroke is the thrombolytic agent recombinant tissue plasminogen activator. α1-Antitrypsin (AAT), a serine proteinase inhibitor with potent anti-inflammatory, anti-apoptotic, antimicrobial, and cytoprotective activities, could be beneficial in stroke. The goal of this study is to test whether AAT can improve ischemic stroke outcome in an established rat model. Middle cerebral artery occlusion was induced in male rats via intracranial (i.c.) microinjection of endothelin-1. Five to 10 minutes after stroke induction, rats received either i.c. or intravenous delivery of human AAT. Cylinder and vibrissae tests were used to evaluate sensorimotor function before and 72 hours after middle cerebral artery occlusion. Infarct volumes were examined via either 2,3,5-triphenyltetrazolium chloride assay or magnetic resonance imaging 72 hours after middle cerebral artery occlusion. Despite equivalent initial strokes, at 72 hours, the infarct volumes of the human AAT treatment groups (local and systemic injection) were statistically significantly reduced by 83% and 63% (P < .0001 and P < .05, respectively) compared with control rats. Human AAT significantly limited sensory motor system deficits. Human AAT could be a potential novel therapeutic drug for the protection against neurodegeneration after ischemic stroke, but more studies are needed to investigate the protective mechanisms and efficacy in other animal models.


Assuntos
Encéfalo/efeitos dos fármacos , Infarto da Artéria Cerebral Média/tratamento farmacológico , Fármacos Neuroprotetores/farmacologia , alfa 1-Antitripsina/farmacologia , Animais , Encéfalo/irrigação sanguínea , Encéfalo/patologia , Encéfalo/fisiopatologia , Citoproteção , Modelos Animais de Doenças , Endotelina-1 , Humanos , Infarto da Artéria Cerebral Média/induzido quimicamente , Infarto da Artéria Cerebral Média/diagnóstico , Infarto da Artéria Cerebral Média/fisiopatologia , Injeções Intravenosas , Imageamento por Ressonância Magnética , Masculino , Microinjeções , Atividade Motora/efeitos dos fármacos , Fármacos Neuroprotetores/administração & dosagem , Ratos Sprague-Dawley , Limiar Sensorial/efeitos dos fármacos , Fatores de Tempo , alfa 1-Antitripsina/administração & dosagem
20.
Med Phys ; 51(2): 1217-1231, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37523268

RESUMO

BACKGROUND: Respiratory motion induces artifacts in reconstructed cardiac perfusion SPECT images. Correction for respiratory motion often relies on a respiratory signal describing the heart displacements during breathing. However, using external tracking devices to estimate respiratory signals can add cost and operational complications in a clinical setting. PURPOSE: We aim to develop a deep learning (DL) approach that uses only SPECT projection data for respiratory signal estimation. METHODS: A modified U-Net was implemented that takes temporally finely sampled SPECT sub-projection data (100 ms) as input. These sub-projections are obtained by reframing the 20-s list-mode data, resulting in 200 sub-projections, at each projection angle for each SPECT camera head. The network outputs a 200-time-point motion signal for each projection angle, which was later aggregated over all angles to give a full respiratory signal. The target signal for DL model training was from an external stereo-camera visual tracking system (VTS). In addition to comparing DL and VTS, we also included a data-driven approach based on the center-of-mass (CoM) strategy. This CoM method estimates respiratory signals by monitoring the axial changes of CoM for counts in the heart region of the sub-projections. We utilized 900 subjects with stress cardiac perfusion SPECT studies, with 302 subjects for testing and the remaining 598 subjects for training and validation. RESULTS: The Pearson's correlation coefficient between the DL respiratory signal and the reference VTS signal was 0.90, compared to 0.70 between the CoM signal and the reference. For respiratory motion correction on SPECT images, all VTS, DL, and CoM approaches partially de-blured the heart wall, resulting in a thinner wall thickness and increased recovered maximal image intensity within the wall, with VTS reducing blurring the most followed by the DL approach. Uptake quantification for the combined anterior and inferior segments of polar maps showed a mean absolute difference from the reference VTS of 1.7% for the DL method for patients with motion >12 mm, compared to 2.6% for the CoM method and 8.5% for no correction. CONCLUSION: We demonstrate the capability of a DL approach to estimate respiratory signal from SPECT projection data for cardiac perfusion imaging. Our results show that the DL based respiratory motion correction reduces artefacts and achieves similar regional quantification to that obtained using the stereo-camera VTS signals. This may enable fully automatic data-driven respiratory motion correction without relying on external motion tracking devices.


Assuntos
Aprendizado Profundo , Humanos , Tomografia Computadorizada de Emissão de Fóton Único , Coração/diagnóstico por imagem , Movimento (Física) , Perfusão , Processamento de Imagem Assistida por Computador/métodos , Artefatos , Imagens de Fantasmas
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa