Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 113
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Int Heart J ; 64(4): 535-542, 2023 Jul 29.
Artigo em Inglês | MEDLINE | ID: mdl-37460322

RESUMO

Rapid reperfusion by primary percutaneous coronary intervention (pPCI) is an established strategy for the treatment of patients with ST-segment elevation myocardial infarction (STEMI). Pre-hospital electrocardiogram (PH-ECG) transmission by the emergency medical services (EMS) facilitates timely reperfusion in these patients. However, evidence regarding the clinical benefits of PH-ECG in individual hospitals is limited.This retrospective, observational study investigated the clinical efficacy of PH-ECG in STEMI patients who underwent pPCI. Of a total of 382 consecutive STEMI patients, 237 were enrolled in the study and divided into 2 groups: a PH-ECG group (n = 77) and non-PH-ECG group (n = 160). Door-to-balloon time (D2BT) was significantly shorter in the PH-ECG group (66 [52-80] min), compared to the non-PH-ECG group (70 [57-88] minutes, P = 0.01). The 30-day all-cause mortality rate was 6% in the PH-ECG group, which was significantly lower than that in the non-PH-ECG group (16%) (P = 0.037, hazard ratio [HR]: 0.38, 95% CI: 0.15-0.98). This trend was particularly evident in severely ill patients when stratified by GRACE score.The use of PH-ECG improved the survival rate of STEMI patients undergoing pPCI due to the improved pre-arrival preparation based on the EMS information. Coordination between EMS and PCI-capable institutes is essential for the management of PH-ECG.


Assuntos
Serviços Médicos de Emergência , Infarto do Miocárdio , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST , Humanos , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia , Intervenção Coronária Percutânea/efeitos adversos , Infarto do Miocárdio/etiologia , Estudos Retrospectivos , Hospitais , Resultado do Tratamento , Eletrocardiografia
2.
Angew Chem Int Ed Engl ; 62(33): e202307228, 2023 Aug 14.
Artigo em Inglês | MEDLINE | ID: mdl-37337312

RESUMO

The photoelectric properties of nontoxic Sn-based perovskite make it a promising alternative to toxic Pb-based perovskite. It has superior photovoltaic performance in comparison to other Pb-free counterparts. The facile oxidation of Sn2+ to Sn4+ presents a notable obstacle in the advancement of perovskite solar cells that utilize Sn, as it adversely affects their stability and performance. The study revealed the presence of a Sn4+ concentration on both the upper and lower surfaces of the perovskite layer. This discovery led to the adoption of a bi-interface optimization approach. A thin layer of Sn metal was inserted at the two surfaces of the perovskite layer. The implementation of this intervention yielded a significant decrease in the levels of Sn4+ and trap densities. The power conversion efficiency of the device was achieved at 14.31 % through the optimization of carrier transportation. The device exhibited operational and long-term stability.

3.
J Cardiovasc Electrophysiol ; 33(8): 1905-1907, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35775820

RESUMO

A 47-year-old man with symptomatic paroxysmal atrial fibrillation (AF) underwent AF ablation. Activation maps during right atrial pacing and sinus rhythm before the ablation revealed distinctive left atrial (LA) propagations with multiple LA breakthrough sites via epicardial connections. A wide area circumferential ablation was not able to achieve a right pulmonary vein (RPV) isolation and required an inner PV ablation to isolate the RPV. Activation maps during different rhythms before the ablation may be helpful to unmask multiple epicardial connections between the RPV and right atrium.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/cirurgia
4.
Pacing Clin Electrophysiol ; 45(2): 219-228, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34919281

RESUMO

INTRODUCTION: Electrogram (EGM) fractionation is often associated with diseased atrial tissue; however, mechanisms for fractionation occurring above an established threshold of 0.5 mV have never been characterized. We sought to investigate during sinus rhythm (SR) the mechanisms underlying bipolar EGM fractionation with high-density mapping in patients with atrial fibrillation (AF). METHODS: Forty-five patients undergoing AF ablation (73% paroxysmal, 27% persistent) were mapped at high density (18562 ± 2551 points) during SR (Rhythmia). Only bipolar EGMs with voltages above 0.5 mV were considered for analysis. When fractionation (> 40 ms and >4 deflections) was detected, we classified the mechanisms as slow conduction, wave-front collision, or a pivot point. The relationship between EGM duration and amplitude, and tissue anisotropy and slow conduction, was then studied using a computational model. RESULTS: Of the 45 left atria analyzed, 133 sites of EGM fragmentation were identified with voltages above 0.5 mV. The most frequent mechanism (64%) was slow conduction (velocity 0.45 m/s ± 0.2) with mean EGM voltage of 1.1 ± 0.5 mV and duration of 54.9 ± 9.4 ms. Wavefront collision was the second most frequent (19%), characterized by higher voltage (1.6 ± 0.9 mV) and shorter duration (51.3 ± 11.3 ms). Pivot points (9%) were associated with the highest degree of fractionation with 70.7 ± 6.6 ms and 1.8 ± 1 mV. In 10 sites (8%) fractionation was unexplained. The EGM duration was significantly different among the 3 mechanisms (p = .0351). CONCLUSION: In patients with a history of AF, EGM fractionation can occur at amplitudes > 0.5 mV when in SR in areas often considered not to be diseased tissue. The main mechanism of EGM fractionation is slow conduction, followed by wavefront collision and pivot sites.


Assuntos
Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas , Idoso , Simulação por Computador , Mapeamento Epicárdico , Feminino , Humanos , Itália , Masculino
5.
Lasers Med Sci ; 37(3): 1567-1573, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34436695

RESUMO

Excimer laser coronary atherectomy (ELCA) is an effective treatment to remove intracoronary thrombi. In the present study, we compared in-hospital mortality in patients with acute myocardial infarction (AMI) who underwent conventional treatment and conventional treatment plus ELCA. Among 656 patients who were admitted to our hospital through the Tokyo CCU Network, 104 patients with AMI who were treated by percutaneous coronary intervention between January 2013 and December 2016 met inclusions criteria and underwent conventional treatment with ELCA (ELCA group) and 89 underwent conventional treatment alone (conventional group). We retrospectively evaluated in-hospital mortality within 30 days and used propensity score (PS) matching to reduce assignment bias and multivariate analysis to detect the predictors of in-hospital mortality. In-hospital mortality rate was significantly lower in the ELCA group before and after PS matching (2.9% vs. 13.5%, p = 0.006 before PS matching, and 2.8% vs. 14.1%, p = 0.016 after PS matching). After PS matching, ß-blocker or statins use, incidence of shock, Killip classification, and door-to-balloon time were not significantly different. A multivariate logistic regression analysis identified ELCA, dyslipidemia, shock, and left ventricular ejection fraction as independent predictors of in-hospital mortality (odds ratio (OR), 0.147, 95% confidence interval [CI], 0.022-0.959, p = 0.045; OR, 0.077, 95% CI, 0.007-0.805, p = 0.032; OR, 6.494, 95% CI, 1.228-34.34, p = 0.028; OR, 0.890, 95% CI, 0.828-0.957, p = 0.002, respectively). Our data indicate that ELCA with the small diameter and low level emission may reduce the in-hospital mortality compared to conventional methods in patients with AMI in drug-eluting stent era.


Assuntos
Aterectomia Coronária , Stents Farmacológicos , Infarto do Miocárdio , Aterectomia Coronária/efeitos adversos , Angiografia Coronária , Humanos , Lasers de Excimer/efeitos adversos , Infarto do Miocárdio/cirurgia , Estudos Retrospectivos , Volume Sistólico , Função Ventricular Esquerda
6.
J Cardiovasc Electrophysiol ; 32(3): 597-604, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33484213

RESUMO

INTRODUCTION: It is important to consider recurrent arrhythmia after catheter ablation for persistent atrial fibrillation (AF) for planning an ablation strategy. However, the studies are limited to pulmonary vein isolation (PVI) plus posterior wall isolation (PWI), which were reported to improve procedural outcomes. The objective of this study is to evaluate the effect of PWI on recurrent arrhythmia. METHODS: This is an observational study on patients with persistent AF comparing PVI plus PWI and PVI only strategies. In PVI plus PWI group, linear ablation of the left atrium roofline and bottom line were performed to achieve PWI after PVI. Some patients with AF recurrence underwent the second procedure. The presence of recurrent arrhythmia and results of the second procedures were evaluated. RESULTS: A total of 181 patients (mean age, 66.9 ± 10.2 years; male, 76.8%) were included. PVI plus PWI group and PVI only group consisted of 90 and 91 patients, respectively. AF recurrence was observed in 28 of 90 (31.1%) patients with PVI plus PWI and in 43 of 91 (47.3%) with PVI only, and log-rank test did not show any significant difference (p = .35). The occurrence of recurrent persistent AF was significantly lower in PVI plus PWI group than in PVI only group (5/90; 5.6% vs. 18/91; 20.9%, p = .002). There was no significant difference between the two groups in recurrent paroxysmal AF and atrial tachycardia (AT). CONCLUSION: PWI, in addition to PVI, for persistent AF was significantly related to fewer episodes of recurrent persistent AF, and it did not increase recurrent AT.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
7.
J Cardiovasc Electrophysiol ; 32(5): 1461-1463, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33783898

RESUMO

The Accufix bipolar active fixation atrial pacing lead (Model 330-801; Telectronics) can have mechanical complications due to a fracture of its J retention wire. An 80-year-old man had the Accufix atrial pacing lead implanted 29 years prior, and surgical removal was required because a part of the lead was perforating the apex of the right ventricle. Regular follow-up examinations are recommended to eliminate the possibility of protrusion and detachment of the J retention wire, even if the clinical course after implantation is stable for a prolonged period.


Assuntos
Eletrodos Implantados , Marca-Passo Artificial , Idoso de 80 Anos ou mais , Eletrodos Implantados/efeitos adversos , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Humanos , Masculino , Marca-Passo Artificial/efeitos adversos
8.
J Cardiovasc Electrophysiol ; 32(1): 41-48, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33206418

RESUMO

INTRODUCTION: In patients with coronary artery disease, a high coronary artery calcium score (CACS) correlates with atrial fibrillation (AF); however, the association between left atrial (LA) remodeling progression and coronary arteriosclerosis is unclear. This study aimed to evaluate the relationship between LA remodeling progression and the CACS. METHODS: This retrospective study enrolled 148 patients with AF (paroxysmal AF, n = 94) who underwent catheter ablation. Voltage mapping for the left atrium and coronary computed tomography for CACS calculations were performed. The ratio of the LA low-voltage area (LA-LVA), defined by values less than 0.5 mV divided by the total LA surface without pulmonary veins, was calculated. Patients with LA-LVA (<0.5 mV) >5% and ≤5% were classified as the LVA (n = 30) and non-LVA (n = 118) groups, respectively. Patient characteristics and CACS values were compared between the two groups. RESULTS: LA volume, age, CHA2 DS2 VASc score, and percentage of female patients were significantly higher, and the estimated glomerular filtration rate was lower in the LVA group than in the non-LVA group. The CACS was significantly higher in the LVA group (248.4 vs. 13.2; p = .001). Multivariate analysis identified the LA volume index and CACS as independent predictors of LA-LVA (<0.5 mV) greater than 5%. The areas under the receiver operating characteristic curves for predicting LA-LVA (<0.5 mV) greater than 5% with CACS were 0.695 in the entire population, 0.782 in men, and 0.587 in women. CONCLUSION: Progression of LA remodeling and coronary artery calcification may occur in parallel. A high CACS may indicate advanced LA remodeling, especially in men.


Assuntos
Fibrilação Atrial , Remodelamento Atrial , Ablação por Cateter , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Cálcio , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Técnicas Eletrofisiológicas Cardíacas , Feminino , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Humanos , Masculino , Estudos Retrospectivos , Caracteres Sexuais
9.
J Cardiovasc Electrophysiol ; 32(3): 570-577, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33476463

RESUMO

BACKGROUND: Ultralow temperature cyroablation (ULTC) is designed to create focal, linear, and circumferential lesions. The aim of this study was to assess the safety, efficacy, and durability of atrial and ventricular ULTC lesions in preclinical large animal models. METHODS AND RESULTS: The ULTC system uses nitrogen near its liquid-vapor critical point to cool 11-cm ablation catheters. The catheter can be shaped to specific anatomies using pre-shaped stylets. ULTC was used in 11 swine and four sheep to create atrial (pulmonary vein isolation and linear ablation) and ventricular lesions. Acute and 90-day success were evaluated by intracardiac mapping and histologic examination. Cryoadherence was observed during all ULTC applications, ensuring catheter stability at target locations. Local electrograms were completely eliminated immediately after the first single-shot ULTC application in 49 of 53 (92.5%) atrial and in 31 of 32 (96.9%) ventricular applications. Lesion depth as measured on histology preparations was 1.96 ± 0.8 mm in atrial and 5.61 ± 2.2 mm in ventricular lesions. In all animals, voltage maps and histology demonstrated transmural and durable lesions without gaps, surrounded by intact collagen fibers without injury to surrounding tissues. Transient coronary spasm could be provoked with endocardial ULTC in the left ventricle in close proximity to a coronary artery. CONCLUSIONS: ULTC created effective and efficient atrial and ventricular lesions in vivo without procedural complications in two large animal models. ULTC lesions were transmural, contiguous, and durable over 3 months.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Animais , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Criocirurgia/efeitos adversos , Átrios do Coração/cirurgia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Veias Pulmonares/cirurgia , Ovinos , Suínos , Temperatura
10.
J Cardiovasc Electrophysiol ; 32(9): 2451-2461, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34314087

RESUMO

INTRODUCTION: Human atria comprise distinct layers. One layer can bypass another, and lead to a downstream centrifugal propagation at their interface. We sought to characterize anatomical substrates, electrophysiological properties, and ablation outcomes of "pseudo-focal" atrial tachycardias (ATs), defined as macroreentrant ATs mimicking focal ATs. METHODS AND RESULTS: We retrospectively analyzed left atrial ATs showing centrifugal propagation with postpacing intervals (PPIs) after entrainment pacing suggestive of a macroreentrant mechanism. A total of 22 patients had pseudo-focal ATs consisting of 15 perimitral and 7 roof-dependent flutters. A low-voltage area was consistently found at the collision site and colocalized with distinct anatomical structures like the: (1) coronary sinus-great cardiac vein bundle (27%), (2) vein of Marshall bundle (18%), (3) Bachmann bundle (27%), (4) septopulmonary bundle (18%), and (5) fossa ovalis (9%). The mean missing tachycardia cycle length (TCL) was 65 ± 31 ms (22%) on the endocardial activation map. PPI was 0 [0-15] ms and 0 [0-21] ms longer than TCL at the breakthrough site and the opposite site, respectively. While feasible in 21 pseudo-focal ATs (95%), termination was better achieved by blocking the anatomical isthmus than ablating the breakthrough site [20/21 (95%) vs. 1/5 (20%); p < .001]. CONCLUSION: Perimitral and roof-dependent flutters with centrifugal propagation are favored by a low-voltage area located at well-identified anatomical structures. Comprehensive entrainment pacing maneuvers are crucial to distinguish pseudo-focal ATs from true focal ATs. Blocking the anatomical isthmus is a better therapeutic option than ablating the breakthrough site.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Taquicardia Supraventricular , Fibrilação Atrial/cirurgia , Átrios do Coração/cirurgia , Humanos , Estudos Retrospectivos , Taquicardia , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/cirurgia , Resultado do Tratamento
11.
Europace ; 23(7): 1052-1062, 2021 07 18.
Artigo em Inglês | MEDLINE | ID: mdl-33564832

RESUMO

AIMS: An incomplete understanding of the mechanism of atrial tachycardia (AT) is a major determinant of ablation failure. We systematically evaluated the mechanisms of AT using ultra-high-resolution mapping in a large cohort of patients. METHODS AND RESULTS: We included 107 consecutive patients (mean age: 65.7 ± 9.2 years, males: 81 patients) with documented endocardial gap-related AT after left atrial ablation for persistent atrial fibrillation (AF). We analysed the mechanism of 134 AT (94 macro-re-entries and 40 localized re-entries) using high-resolution activation mapping in combination with high-density voltage and entrainment mapping. Voltage in the conducting channels may be extremely low, even <0.1 mV (0.14 ± 0.095 mV, 51 of 134 AT, 41%), and almost always <0.5 mV (0.03-0.5 mV, 133 of 134 AT, 99.3%). The use of multipolar Orion, HDGrid, and Pentaray catheters improved our accuracy in delineating ultra-low-voltage areas critical for maintenance of the circuit of endocardial gap-related AT. Conventional ablation catheters often do not detect any signal (noise level) even using adequate contact force, and only multipolar catheters of small electrodes and shorter interelectrode space can detect clear fractionated low-amplitude and high frequency signals, critical for re-entry maintenance. We performed a diagnosis in 112 out of 134 AT (83.6%) using only activation mapping and in 134 out of 134 AT (100%) using the combination of activation and entrainment mapping. CONCLUSION: High-resolution activation mapping in combination with high-density voltage and entrainment mapping is the ideal strategy to delineate the critical part of the circuit in endocardial gap-related re-entrant AT after AF ablation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Taquicardia Supraventricular , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Taquicardia , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/etiologia , Taquicardia Supraventricular/cirurgia
12.
Pacing Clin Electrophysiol ; 44(5): 782-791, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33687764

RESUMO

Beyond pulmonary vein isolation, the two main additional strategies: Cox-Maze procedure or targeting of electrical signatures (focal bursts, rotational activities, meandering wavelets), remain controversial. High-density mapping of these arrhythmias has demonstrated firstly that a patchy lesion set is highly proarrhythmogenic, favoring macro-re-entry through conduction slowing and providing pivots for localized re-entry. Secondly, discrete anatomical structures such as the Vein or Ligament of Marshall (VOM/LOM) and the coronary sinus (CS) have epicardial muscular bundles that are more frequently involved in re-entry than previously thought. The Marshall Bundle can be ablated at any point along its course from the mid-to-distal coronary sinus to the left atrial appendage. If necessary, the VOM may be directly ablated using ethanol infusion to eliminate PV contributions and produce conduction block across the mistral isthmus. Ethanol ablation of the VOM, supplemented with RF ablation, may be more effective in producing conduction block at the mitral isthmus than repeat RF ablation alone.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Ligamentos/cirurgia , Fibrilação Atrial/fisiopatologia , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Ligamentos/fisiopatologia
13.
Heart Vessels ; 36(7): 1009-1015, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33475763

RESUMO

Intracardiac echocardiography (ICE) utilized in conjunction with three-dimensional (3-D) mapping systems could enhance ventricular tachycardia (VT) ablation procedures. ICE has been increasingly used in VT ablation; however, the safety and effectiveness of VT ablation under the combined use of ICE remains unclear. The present study aimed to analyze the safety and short-term effects of VT ablation with or without ICE. We retrospectively enrolled patients who underwent initial VT ablation with a combination of ICE and a 3-D mapping system within 3 days of hospitalization and discharged from April 2011 to March 2017 using a nationwide Japanese inpatient database. Following enrollment, we conducted a propensity score-matching analysis to compare safety (in-hospital complications) and effectiveness (readmission within 30 days after discharge due to cardiovascular disease and readmissions within 30 days for repeat VT ablations) between patients who underwent VT ablation with (ICE group) and without ICE (non-ICE group). 3-D mapping systems were applied to both groups. We identified 5,804 eligible patients (1,272 and 4,532 patients in the ICE and non-ICE groups, respectively). One-to-one propensity score matching created a total of 1,147 pairs between the ICE and non-ICE groups. The ICE group showed a significantly lower prevalence of cardiac tamponade than the non-ICE group. There were no significant differences observed between the two groups regarding other outcomes concerning safety and effectiveness. Ventricular tachycardia ablation with ICE used in combination with a 3-D mapping system may reduce cardiac tamponade; however, no additional clinical advantages were noted in terms of safety and effectiveness.


Assuntos
Mapeamento Potencial de Superfície Corporal/métodos , Técnicas de Imagem Cardíaca/métodos , Ablação por Cateter/métodos , Ecocardiografia/métodos , Taquicardia Ventricular/diagnóstico , Adulto , Idoso , Feminino , Humanos , Incidência , Japão/epidemiologia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Taquicardia Ventricular/epidemiologia , Taquicardia Ventricular/cirurgia , Resultado do Tratamento
14.
J Cardiovasc Electrophysiol ; 31(11): 3061-3063, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32889746

RESUMO

We describe a 47-year-old woman with ischemic ventricular tachycardia (VT) with repetitive implantable cardioverter-defibrillator shocks, requiring ablation. Preprocedural computed tomography (CT) demonstrated a single anatomical channel on the inferior-basal infarcted area between less than a 3-mm wall-thinning area and the mitral annulus, which suggested the circuit of two VTs observed. In addition, distribution of less than 2 mm and less than 3 mm wall-thinning area can explain the mechanism of the variation of the QRS morphology and S-QRS interval during entrainment. Ablation in this region resulted in no VT inducibility and the absence of any VTs for 2 years. CT wall thinning data may allow us to understand the mechanism and circuit of VT and aid VT ablation procedures.


Assuntos
Ablação por Cateter , Desfibriladores Implantáveis , Taquicardia Ventricular , Feminino , Humanos , Pessoa de Meia-Idade , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/cirurgia , Tomografia , Tomografia Computadorizada por Raios X
15.
J Cardiovasc Electrophysiol ; 31(8): 2013-2021, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32468685

RESUMO

INTRODUCTION: Successful pulmonary vein isolation (PVI) can improve the quality of life (QOL) of patients with atrial fibrillation (AF). However, the role of durable PVI for such QOL improvement is not known. The aim of this study was to clarify the effectiveness of durable PVI in improving the QOL of patients with AF. METHODS AND RESULTS: We assessed 119 patients who underwent PVI (age 66.4 ± 9.6 years, 104 paroxysmal AF). A scheduled electrophysiological study was performed 6 months after the first PVI session-regardless of recurrence of AF-to assess the durability of PVI and to identify and re-isolate reconnected pulmonary veins. QOL scores were evaluated by an AF-specific QOL questionnaire and checked at baseline, 6 months, and 1 year after the first session. In patients without AF recurrence (nonrecurrence group, n = 93), the scores at 6 months improved compared with those at baseline; conversely, the scores did not improve in patients with AF recurrence (n = 26). Nevertheless, the scores at 1 year improved compared with those at 6 months in both groups. Within the nonrecurrence group, the score difference between 6 months and baseline was higher in the durable PVI group (n = 58) than that in the nondurable PVI group (n = 35). CONCLUSIONS: The QOL of AF patients improved by the resumption of sinus rhythm following PVI. Patients with durable PVI had increased QOL scores compared with those with nondurable PVI. The durability of PVI may achieve further improvements in the QOL of patients with AF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Humanos , Veias Pulmonares/cirurgia , Qualidade de Vida , Recidiva , Resultado do Tratamento
16.
J Cardiovasc Electrophysiol ; 31(6): 1298-1306, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32270566

RESUMO

INTRODUCTION: This study aimed to compare touch-up ablation (TUA) rates and pulmonary vein isolation (PVI) durability of hot balloon ablation (HBA) and cryoballoon ablation (CBA) in paroxysmal atrial fibrillation (PAF) patients. METHODS: In total, 137 PAF patients were enrolled in the study. Among them, 59 underwent two HBA procedures at 6-month intervals and 78 patients underwent two CBA sessions, both regardless of atrial fibrillation recurrence. Propensity score matching was performed to estimate similar patient characteristics between the HBA and CBA groups. RESULTS: Each group comprised of 46 matched patients for comparison. The TUA rate at the first session was higher for HBA (49 of 184 PVs) than for CBA (20 PVs) (P = .01), with the highest incidence at the left superior pulmonary vein (LSPV). The rates of PVI durability at the second session performed 7 months later were similar between HBA (168 of 184 PVs) and CBA (162 PVs) groups. The PVI durability rate at the TUA sites of the first session was higher for HBA than for CBA (41 of 49 PVs vs 10 PVs, respectively; P = .01). Fifty percent of the patients underwent HBA at 73°C for the LSPV. HBA performed at 73°C yielded a lower TUA rate than that at 70°C (16 of 23 PVs vs 7 of 23 PVs; P = .008). CONCLUSIONS: While PVI durability was similar between HBA and CBA, the TUA rate was higher for HBA than for CBA, especially on the LSPV. For LSPV, HBA at a balloon temperature of 73°C may reduce the TUA rate.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Criocirurgia , Temperatura Alta/uso terapêutico , Veias Pulmonares/cirurgia , Potenciais de Ação , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Cateteres Cardíacos , Ablação por Cateter/efeitos adversos , Ablação por Cateter/instrumentação , Criocirurgia/efeitos adversos , Criocirurgia/instrumentação , Feminino , Frequência Cardíaca , Temperatura Alta/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/fisiopatologia , Recidiva , Reoperação , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
17.
J Cardiovasc Electrophysiol ; 31(11): 2836-2845, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32757434

RESUMO

BACKGROUND: Radiofrequency (RF) power is routinely considered during RF application. In contrast, impedance has been relatively poorly studied, despite also influencing RF lesion creation. The aim of this study was to examine the influence of electric impedance on RF lesion characteristics and on clinical RF ablation parameters. METHODS AND RESULTS: In the first part of the study, power and impedance were systematically varied and the resulting current was calculated using custom-made software. In the second part of the study, ablation lesions (n = 40) were analyzed in a porcine ex vivo model. RF applications were delivered in cardiac muscle preparations with systematically varied values of electric impedance using a contact force ablation catheter. In the third part of the study, n = 3378 clinical RF applications were analyzed, power, impedance, and current data were exported and correlated with clinical patient data. 20 ± 3 W/80 Ω, 30 ± 3 W/120 Ω, 40 ± 3 W/160 Ω, and 50 ± 3 W/200 Ω RF applications resulted in 498 ± 40, 499 ± 26, 500 ± 20, and 500 ± 16 mA RF current, which were not significantly different (p = .32). Ablation lesions were significantly different in depth and diameter when applied with the same power but different impedances (p < .01); lesion sizes decreased when increasing impedance. In clinical data, a large range of delivered current (e.g., 39-40 W: 530-754 mA) was measured, due to variations in impedance. CONCLUSIONS: RF lesion creation is determined by current rather than by power. During clinical RF ablation procedures, impedance significantly influences current delivery and varies considerably between patients. Impedance and current are clinically relevant parameters that should be considered during RF ablation.


Assuntos
Ablação por Cateter , Ablação por Radiofrequência , Animais , Ablação por Cateter/efeitos adversos , Impedância Elétrica , Humanos , Miocárdio , Ablação por Radiofrequência/efeitos adversos , Suínos
18.
J Cardiovasc Electrophysiol ; 31(7): 1640-1648, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32437007

RESUMO

BACKGROUND: No study to date has used high-density mapping to investigate the relationship between prior radiofrequency (RF) lesions for persistent atrial fibrillation (PsAF) ablation and subsequent atrial tachycardias (ATs). METHODS: From 41 consecutive patients who underwent AT ablation at a second procedure using an ultrahigh-density mapping system, 22 patients (38 ATs) were included as they also had complete maps with a multipolar catheter and three-dimensional (3D) mapping system at the time of the first PsAF ablation procedure. We, therefore, compared voltage maps from the first AF ablation procedure to those from the subsequent AT ablation procedure, as well as the lesion sets used for AF ablation vs the activation patterns in AT during the second procedure. RESULTS: In the 38 ATs, 211 of 285 analyzed atrial areas displayed low voltage area (LVA) (74%). Eighteen percent (38/211) existed before the index ablation for AF while 82% (173/211) were newly identified as LVA during the second procedure. Ninety-nine percent (172/173) of the newly developed LVA colocalized with RF lesions delivered for PsAF. Of the 38 ATs, 89.5% (34/38) AT circuits were associated with newly developed LVA due to RF lesions whilst 10.5% (4/38) AT circuits were associated with pre-existing LVA observed at the index procedure. No AT circuit was completely independent from index RF lesions in this series. CONCLUSIONS: Analysis of detailed 3D electroanatomical mapping demonstrates that most ATs after PsAF ablation are involving LVAs due to index RF lesions.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Taquicardia Supraventricular , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Técnicas Eletrofisiológicas Cardíacas , Humanos , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/cirurgia , Resultado do Tratamento
19.
J Cardiovasc Electrophysiol ; 31(6): 1332-1339, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32282970

RESUMO

BACKGROUND: Use of lesion metric indices is a proposed strategy to support pulmonary vein isolation procedures and these indices show good correlations with lesion sizes. The aim of this in silico study is to provide a detailed analysis of radiofrequency (RF) settings, including high-power short-duration (HPSD) settings, and resulting lesion metric indices. METHODS AND RESULTS: A software program was designed which simulated virtual RF ablations. Lesion metric indices (Ablation index: AI, Lesion size index: LSI) were calculated based on underlying RF settings (contact force [CF], power, duration). In series of calculations, the applied settings were varied within defined ranges (CF: 1-80 g, power: 1-60 W, duration: 1-60 seconds). Overall, n = 388 000 virtual ablations were calculated. The resulting lesion metric indices were compared with each other and analyzed in relation to respective RF settings. Increasing contact force from 1 to 10 g resulted in a 4.4-fold LSI value, whilst increasing contact force from 10 to 20g resulted in a 1.5-fold value (P < .01). When RF power was increased by 10 W, lesion metric indices increased between 1.3- and 1.6-fold. A prolongation of RF duration by 10 seconds resulted in a 1.2-to-1.3-fold increase of lesion metric indices. HPSD RF applications of 50 W, 11 to 13 seconds, and 60 W, 8 to 10 seconds resulted in equivalent lesion metric indices when compared with 30 W, 30 seconds conventional ablations. CONCLUSIONS: The findings support the clinical use of contact forces within a 10 to 20 g range. AI is more sensitive to RF duration, whereas LSI is more sensitive to contact force. HPSD RF settings can successfully be derived from lesion metric indices.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Simulação por Computador , Modelos Cardiovasculares , Veias Pulmonares/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Cateteres Cardíacos , Ablação por Cateter/efeitos adversos , Ablação por Cateter/instrumentação , Humanos , Pressão , Veias Pulmonares/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
20.
Europace ; 22(8): 1252-1260, 2020 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-32594180

RESUMO

AIMS: We hypothesized that an epicardial approach using ethanol infusion in the vein of Marshall (EIVOM) may improve the result of ablation for perimitral flutter (PMF). METHODS AND RESULTS: We studied 103 consecutive patients with PMF undergoing high-resolution mapping. The first 71 were treated with radiofrequency (RF) ablation alone (RF-group), and the next 32 underwent EIVOM followed by RF on the endocardial and epicardial mitral isthmus (EIVOM/RF-group). Contact force was not measured during ablation. Acute and 1-year outcomes were compared. Flutter termination rates were similar between the RF-group (63/71, 88.7%) and EIVOM/RF-group (31/32, 96.8%, P = 0.27). Atrial tachycardia (AT) terminated with EIVOM alone in 22/32 (68.6%) in the EIVOM/RF-group. Bidirectional block of mitral isthmus was always achieved in the EIVOM/RF-group, but significantly less frequently achieved in the RF-group (62/71, 87.3%; P = 0.05). Median RF duration for AT termination/conversion was shorter [0 (0-6) s in the EIVOM/RF-group than 312 (55-610) s in the RF-group, P < 0.0001], as well as for mitral isthmus block in the EIVOM/RF-group [246 (0-663) s] than in the RF-group [900 (525-1310) s, P < 0.0001]. Pericardial effusion was observed in 1/32 (3.2%) in EIVOM/RF-group and 5/71 (7.0%) in RF-group (P = 0.66); two in RF-group required drainage and one of them developed subsequent ischaemic stroke. One-year follow-up demonstrated fewer recurrences in the EIVOM/RF-group [6/32 (18.8%)] than in the RF-group [29/71 (40.8%), P = 0.04]. By multivariate analysis, only EIVOM was significantly associated with less AT recurrence (hazard ratio = 0.35, P = 0.018). CONCLUSION: Ethanol infusion in the vein of Marshall may reduce RF duration required for PMF termination as well as for mitral isthmus block without severe complications, and the mid-term outcome may be improved by this approach.


Assuntos
Fibrilação Atrial , Flutter Atrial , Isquemia Encefálica , Ablação por Cateter , Acidente Vascular Cerebral , Fibrilação Atrial/cirurgia , Flutter Atrial/diagnóstico , Flutter Atrial/tratamento farmacológico , Flutter Atrial/cirurgia , Etanol , Humanos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa