Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Card Fail ; 29(7): 1046-1055, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36958391

RESUMO

BACKGROUND: Left ventricular (LV) volume reshaping reduces myocardial wall stress and may induce reverse remodeling in patients with heart failure with reduced ejection fraction. The AccuCinch Transcatheter Left Ventricular Restoration system consists of a series of anchors connected by a cable implanted along the LV base that is cinched to the basal free wall radius. We evaluated the echocardiographic and clinical outcomes following transcatheter left ventricular restoration. METHODS AND RESULTS: We analyzed 51 heart failure patients with a left ventricular ejection fraction between 20% and 40%, with no more than 2+ mitral regurgitation treated with optimal medical therapy, who subsequently underwent transcatheter left ventricular restoration. Serial echocardiograms, Kansas City Cardiomyopathy Questionnaire scores, and 6-minute walk test distances were measured at baseline through 12 months. Primary analysis end point was change in end-diastolic volume at 12 months compared with baseline. Patients (n = 51) were predominantly male (86%) with a mean age of 56.3 ± 13.1 years. Fluoroscopy showed LV free wall radius decreased by a median of 9.2 mm amounting to a 29.6% decrease in the free wall arc length. At 12 months, the LV end-diastolic volume decreased by 33.6 ± 34.8 mL (P < .01), with comparable decreases in the LV end-systolic volume. These decreases were associated with significant improvements in the overall Kansas City Cardiomyopathy Questionnaire score (16.4 ± 18.7 points; P < .01) and 6-minute hall walk test distance (45.9 ± 83.9 m; P < .01). There were no periprocedural deaths; through the 1-year follow-up, 1 patient died (day 280) and 1 patient received a left ventricular assist device (day 13). CONCLUSIONS: In patients with heart failure with reduced ejection fraction without significant mitral regurgitation receiving optimal medical therapy, the AccuCinch System resulted in decreases of LV volume, as well as improved quality of life and exercise endurance. A randomized trial is ongoing (NCT04331769).


Assuntos
Cardiomiopatias , Insuficiência Cardíaca , Insuficiência da Valva Mitral , Disfunção Ventricular Esquerda , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Qualidade de Vida , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda , Remodelação Ventricular
4.
Circ J ; 81(10): 1484-1489, 2017 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-28450663

RESUMO

BACKGROUND: Despite several negative prospective randomized trials on the efficacy of patent foramen ovale (PFO) occlusion, the discussion on indications is ongoing. Because the incidence of paradoxical coronary embolism through a PFO is unknown, we investigated the risk of paradoxical embolic myocardial infarction over a period of 13 years.Methods and Results:We conducted a retrospective and a prospective study. In the former, we searched the hospital database of a tertiary referral center for cases of acute myocardial infarction (AMI) during the past 10 years and screened them for possible paradoxical MIs. On this basis we started a prospective evaluation over 39 months in another tertiary referral center. All patients with AMI and normal coronary arteries were screened for PFO and if no other reason for the AMI could be found, the case was judged as presumed paradoxical embolism. In the retrospective analysis we found 22 cases (0.45%) of presumed paradoxical coronary artery embolism under 4,848 AMI. In the prospective study there were 11 presumed paradoxical coronary artery embolisms among 1,654 patients with AMI, representing an incidence of 0.67%. CONCLUSIONS: Our findings demonstrated that well below 1% of AMIs are caused by paradoxical embolism via an interatrial communication. Although this percentage appears low, it is not a negligible number of patients based on the huge number of MIs occurring in the industrialized world.


Assuntos
Embolia Paradoxal/complicações , Forame Oval Patente/fisiopatologia , Infarto do Miocárdio/etiologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/epidemiologia , Estudos Prospectivos , Estudos Retrospectivos , Adulto Jovem
5.
Catheter Cardiovasc Interv ; 88(2): 193-200, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26423017

RESUMO

OBJECTIVES: To assess the safety and efficacy of fractional flow reserve (FFR) guided paclitaxel-coated balloon (PCB) treatment for de novo coronary artery lesions. BACKGROUND: There is limited data on PCB treatment for de novo lesions especially of major epicardial coronary arteries. METHODS: Sixty-six patients with 67 de novo lesions who underwent successful plain old balloon angioplasty (POBA) were included. If POBA-FFR was favorable (≥ 0.85), PCB was applied and if POBA-FFR was <0.85, stent implantation was preferred over PCB. RESULTS: Forty-five lesions were treated with PCB (67.2%) and 22 lesions with stents (32.8%). Dual antiplatelet therapy duration was 6 weeks. Late luminal loss with PCB was significantly less than stent (0.05 ± 0.27 mm vs. 0.40 ± 0.54 mm, P = 0.022). The baseline FFR of target lesions was 0.69 ± 0.16 in PCB and 0.60 ± 0.11 in stent group (P = 0.015), however, the FFR at 9 months was not different between groups (0.85 ± 0.08 in PCB vs. 0.85 ± 0.05 in stent group, P = 0.973). At 1 year, one myocardial infarction and one target lesion revascularization related to in-stent restenosis were detected, both in the stent group. CONCLUSION: POBA-FFR-guided PCB treatment is safe and effective for de novo coronary lesions with good anatomical and physiological patency at mid-term follow-up. © 2015 Wiley Periodicals, Inc.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Cateteres Cardíacos , Fármacos Cardiovasculares/administração & dosagem , Materiais Revestidos Biocompatíveis , Doença da Artéria Coronariana/terapia , Vasos Coronários/efeitos dos fármacos , Stents Farmacológicos , Reserva Fracionada de Fluxo Miocárdico/efeitos dos fármacos , Paclitaxel/administração & dosagem , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Fármacos Cardiovasculares/efeitos adversos , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/fisiopatologia , Reestenose Coronária/etiologia , Vasos Coronários/fisiopatologia , Quimioterapia Combinada , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Paclitaxel/efeitos adversos , Inibidores da Agregação Plaquetária/administração & dosagem , Valor Preditivo dos Testes , Estudos Prospectivos , Sistema de Registros , República da Coreia , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular/efeitos dos fármacos
6.
JACC Heart Fail ; 11(8 Pt 2): 1103-1117, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36939661

RESUMO

BACKGROUND: Many patients with heart failure and preserved ejection fraction have no overt volume overload and normal resting left atrial (LA) pressure. OBJECTIVES: This study sought to characterize patients with normal resting LA pressure (pulmonary capillary wedge pressure [PCWP] <15 mm Hg) but exercise-induced left atrial hypertension (EILAH). METHODS: The REDUCE LAP-HF II (A Study to Evaluate the Corvia Medical, Inc. IASD System II to Reduce Elevated Left Atrial Pressure in Patients With Heart Failure) trial randomized 626 patients with ejection fraction ≥40% and exercise PCWP ≥25 mm Hg to atrial shunt or sham procedure. The primary trial outcome, a hierarchical composite of death, heart failure hospitalization, intensification of diuretics, and change in health status was compared between patients with EILAH and those with heart failure and resting left atrial hypertension (RELAH). RESULTS: Patients with EILAH (29%) had similar symptom severity, but lower natriuretic peptide levels, higher 6-minute walk distance, less atrial fibrillation, lower left ventricular mass, smaller LA volumes, lower E/e', and better LA strain. PCWP was lower at rest, but had a larger increase with exercise in EILAH. Neither group as a whole had a significant effect from shunt therapy vs sham. Patients with EILAH were more likely to have characteristics associated with atrial shunt responsiveness (peak exercise pulmonary vascular resistance <1.74 WU) and no pacemaker (63% vs 46%; P < 0.001). The win ratio for the primary outcome was 1.56 (P = 0.08) in patients with EILAH and 1.51 (P = 0.04) in those with RELAH when responder characteristics were present. CONCLUSIONS: Patients with EILAH had similar symptom severity but less advanced myocardial and pulmonary vascular disease. This important subgroup may be difficult to diagnose without invasive exercise hemodynamics, but it has characteristics associated with favorable response to atrial shunt therapy. (A Study to Evaluate the Corvia Medical, Inc. IASD System II to Reduce Elevated Left Atrial Pressure in Patients With Heart Failure [REDUCE LAP-HF TRIAL II]; NCT03088033).


Assuntos
Fibrilação Atrial , Insuficiência Cardíaca , Hipertensão , Humanos , Fibrilação Atrial/complicações , Fibrilação Atrial/terapia , Cateterismo Cardíaco , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/diagnóstico , Volume Sistólico/fisiologia , Função Ventricular Esquerda
8.
Circulation ; 119(23): 2986-94, 2009 Jun 16.
Artigo em Inglês | MEDLINE | ID: mdl-19487593

RESUMO

BACKGROUND: Treatment of in-stent restenosis with paclitaxel-coated balloon catheter as compared with plain balloon angioplasty has shown surprisingly low late lumen loss at 6 months and fewer major adverse cardiac events up to 2 years. We compared the efficacy and safety of a paclitaxel-coated balloon with a paclitaxel-eluting stent as the current standard of care. METHODS AND RESULTS: One hundred thirty-one patients with coronary in-stent restenosis were randomly assigned to treatment by a paclitaxel-coated balloon (3 microg/mm2) or a paclitaxel-eluting stent. The main inclusion criteria encompassed diameter stenosis of > or =70% and < or =22 mm in length, with a vessel diameter of 2.5 to 3.5 mm. The primary end point was angiographic in-segment late lumen loss. Quantitative coronary angiography revealed no differences in baseline parameters. At 6 months follow-up, in-segment late lumen loss was 0.38+/-0.61 mm in the drug-eluting stent group versus 0.17+/-0.42 mm (P=0.03) in the drug-coated balloon group, resulting in a binary restenosis rate of 12 of 59 (20%) versus 4 of 57 (7%; P=0.06). At 12 months, the rate of major adverse cardiac events were 22% and 9%, respectively (P=0.08). This difference was primarily due to the need for target lesion revascularization in 4 patients (6%) in the coated-balloon group, compared with 10 patients (15%) in the stent group (P=0.15). CONCLUSIONS: Treatment of coronary in-stent restenosis with the paclitaxel-coated balloon was at least as efficacious and as well tolerated as the paclitaxel-eluting stent. For the treatment of in-stent restenosis, inhibition of re-restenosis does not require a second stent implantation.


Assuntos
Angioplastia Coronária com Balão , Reestenose Coronária/terapia , Stents Farmacológicos , Paclitaxel/administração & dosagem , Moduladores de Tubulina/administração & dosagem , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Angiografia Coronária , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/prevenção & controle , Stents Farmacológicos/efeitos adversos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Inibidores da Agregação Plaquetária/uso terapêutico
9.
J Am Coll Cardiol ; 75(9): 1017-1028, 2020 03 10.
Artigo em Inglês | MEDLINE | ID: mdl-32138961

RESUMO

BACKGROUND: Drug-coated balloons (DCBs) are accepted treatment strategies for coronary in-stent restenosis and are under clinical investigation for lesions without prior stent implantation. A recently published meta-analysis suggested an increased risk of death associated with the use of paclitaxel-coated devices in the superficial femoral artery. The reasons are incompletely understood as potential underlying pathomechanisms remain elusive, and no relationship to the administered dose has been documented. OBJECTIVES: The purpose of this analysis was to investigate the available data on survival after coronary intervention with paclitaxel-coated balloons from randomized controlled trials (RCTs). METHODS: PubMed, Web of science, and the Cochrane library database were searched, and a meta-analysis from RCT was performed comparing DCB with non-DCB devices (such as conventional balloon angioplasty, bare-metal stents, or drug-eluting stents) for the treatment of coronary in-stent restenosis or de novo lesions. The primary outcome was all-cause death. The number of patients lost to follow-up was observed at different time points. Risk estimates are reported as risk ratios (RRs) with 95% confidence intervals (CIs). RESULTS: A total of 4,590 patients enrolled in 26 RCTs published between 2006 and 2019 were analyzed. At follow-up of 6 to 12 months, no significant difference in all-cause mortality was found, however, with numerically lower rates after DCB treatment (RR: 0.74; 95% CI: 0.51 to 1.08; p = 0.116). Risk of death at 2 years (n = 1,477, 8 RCTs) was similar between the 2 groups (RR: 0.84; 95% CI: 0.51 to 1.37; p = 0.478). After 3 years of follow-up (n = 1,775, 9 RCTs), all-cause mortality was significantly lower in the DCB group when compared with control treatment (RR: 0.73; 95% CI: 0.53 to 1.00; p = 0.047) with a number needed to treat of 36 to prevent 1 death. A similar reduction was seen in cardiac mortality (RR: 0.53; 95% CI: 0.33 to 0.85; p = 0.009). CONCLUSIONS: In this meta-analysis, the use of paclitaxel DCBs for treatment of coronary artery disease was not associated with increased mortality, as has been suggested for peripheral arteries. On the contrary, use of coronary paclitaxel-coated balloons was associated with a trend toward lower mortality when compared with control treatments.


Assuntos
Angioplastia Coronária com Balão/mortalidade , Antineoplásicos Fitogênicos/administração & dosagem , Paclitaxel/administração & dosagem , Humanos , Ensaios Clínicos Controlados Aleatórios como Assunto
10.
JACC Cardiovasc Interv ; 13(12): 1391-1402, 2020 06 22.
Artigo em Inglês | MEDLINE | ID: mdl-32473887

RESUMO

Although drug-eluting stents are still the default interventional treatment of coronary artery disease, drug-coated balloons (DCBs) represent a novel alternative therapeutic strategy in certain anatomic conditions. The effect of DCBs is based on the fast and homogenous transfer of antiproliferative drugs into the vessel wall during single balloon inflation by means of a lipophilic matrix without the use of permanent implants. Although their use is established for in-stent restenosis of both bare-metal and drug-eluting stents, recent randomized clinical data demonstrate a good efficacy and safety profile in de novo small-vessel disease and high bleeding risk. In addition, there are other emerging indications (e.g., bifurcation lesions, large-vessel disease, diabetes mellitus, acute coronary syndromes). Because the interaction among the different delivery balloon designs, doses, formulations, and release kinetics of the drugs used is important, there seems to be no "class effect" of DCBs. On the basis of the amount of recently published data, the International DCB Consensus Group provides this update of previous recommendations summarizing the historical background, technical considerations such as choice of device and implantation technique, possible indications, and future perspectives.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Cateteres Cardíacos , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/mortalidade , Fármacos Cardiovasculares/efeitos adversos , Fármacos Cardiovasculares/farmacocinética , Tomada de Decisão Clínica , Consenso , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Stents Farmacológicos , Desenho de Equipamento , Humanos , Fatores de Risco , Resultado do Tratamento
11.
JAMA ; 297(17): 1883-91, 2007 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-17473298

RESUMO

CONTEXT: Because acute decompensated heart failure causes substantial morbidity and mortality, there is a need for agents that at least improve hemodynamics and relieve symptoms without adversely affecting survival. OBJECTIVE: To assess the effect of a short-term intravenous infusion of levosimendan or dobutamine on long-term survival. DESIGN, SETTING, AND PATIENTS: The Survival of Patients With Acute Heart Failure in Need of Intravenous Inotropic Support (SURVIVE) study was a randomized, double-blind trial comparing the efficacy and safety of intravenous levosimendan or dobutamine in 1327 patients hospitalized with acute decompensated heart failure who required inotropic support. The trial was conducted at 75 centers in 9 countries and patients were randomized between March 2003 and December 2004. INTERVENTIONS: Intravenous levosimendan (n = 664) or intravenous dobutamine (n = 663). MAIN OUTCOME MEASURE: All-cause mortality at 180 days. RESULTS: All-cause mortality at 180 days occurred in 173 (26%) patients in the levosimendan group and 185 (28%) patients in the dobutamine group (hazard ratio, 0.91; 95% confidence interval, 0.74-1.13; P = .40). The levosimendan group had greater decreases in B-type natriuretic peptide level at 24 hours that persisted through 5 days compared with the dobutamine group (P<.001 for all time points). There were no statistical differences between treatment groups for the other secondary end points (all-cause mortality at 31 days, number of days alive and out of the hospital, patient global assessment, patient assessment of dyspnea at 24 hours, and cardiovascular mortality at 180 days). There was a higher incidence of cardiac failure in the dobutamine group. There were higher incidences of atrial fibrillation, hypokalemia, and headache in the levosimendan group. CONCLUSION: Despite an initial reduction in plasma B-type natriuretic peptide level in patients in the levosimendan group compared with patients in the dobutamine group, levosimendan did not significantly reduce all-cause mortality at 180 days or affect any secondary clinical outcomes. TRIAL REGISTRATION: clinicaltrials.gov Identifier: NCT00348504.


Assuntos
Cardiotônicos/uso terapêutico , Dobutamina/uso terapêutico , Insuficiência Cardíaca/tratamento farmacológico , Hidrazonas/uso terapêutico , Piridazinas/uso terapêutico , Doença Aguda , Idoso , Método Duplo-Cego , Feminino , Insuficiência Cardíaca/sangue , Insuficiência Cardíaca/mortalidade , Humanos , Infusões Intravenosas , Masculino , Pessoa de Meia-Idade , Peptídeo Natriurético Encefálico/sangue , Simendana , Análise de Sobrevida
13.
Clin Res Cardiol ; 105(7): 613-21, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26768146

RESUMO

OBJECTIVES: We set out to investigate the benefit of distal main or side branch treatment with a DCB compared to POBA in coronary bifurcation lesions. BACKGROUND: The standard treatment of bifurcation lesions is application of a DES to the main branch with provisional side branch stenting. While this resulted in considerable improvement in overall MACE rate suboptimal side branch results remained a problem. METHODS: The study was performed from 2011 to 2013 in six German centers. Native bifurcation lesions were included if side branch vessel diameter was ≥2 and ≤3.5 mm and no proximal main branch lesions was found. After successful predilatation randomization was performed to either DCB application or no further treatment. Follow-up angiograms for QCA analysis were done after 9 months. Primary endpoint was late lumen loss (LLL). RESULTS: 64 patients were successfully randomized. Minimal lumen diameter and grade of stenosis were equal in both groups. Only five stents were used as bail out. Angiographic follow-up was achieved in 75 % of patients. No patient died. There was one NSTEMI in the POBA group. Restenosis rate was 6 % in the DCB group vs 26 % in the POBA group (p = 0.045). TLR was necessary in one patient of the DCB group vs three patients of the POBA. The primary endpoint LLL was 0.13 mm in the DCB vs 0.51 mm in the POBA group (p = 0.013). CONCLUSION: In bifurcation lesions that show only class A or B dissection and recoil not beyond 30 % the use of DCBs is a sound strategy.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Cateteres Cardíacos , Fármacos Cardiovasculares/administração & dosagem , Materiais Revestidos Biocompatíveis , Estenose Coronária/terapia , Paclitaxel/administração & dosagem , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Fármacos Cardiovasculares/efeitos adversos , Angiografia Coronária , Estenose Coronária/diagnóstico por imagem , Desenho de Equipamento , Feminino , Alemanha , Humanos , Masculino , Pessoa de Meia-Idade , Paclitaxel/efeitos adversos , Índice de Gravidade de Doença , Stents , Fatores de Tempo , Resultado do Tratamento
14.
Int J Cardiol ; 225: 262-267, 2016 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-27741486

RESUMO

BACKGROUND: Chronic total occlusions remain one of the biggest challenges for interventional cardiologists and the high risk of restenosis and stent thrombosis is still a major problem. Drug-coated balloons showed favorable results for the treatment of in-stent restenosis and other lesion types. The aim of this study was to evaluate the feasibility and outcome of a drug-coated balloon only approach for chronic total occlusion. METHODS: We included 34 patients with a native chronic total occlusion treated only by drug-coated balloons. A visual residual stenosis of 30% or less without major dissection was considered a satisfactory percutaneous intervention result according to the German Consensus Group recommendations for drug-coated balloon use. We collected clinical and procedural data. Angiograms were conducted during the procedure and at follow-up. Quantitative coronary analysis was performed and mean and minimal lumen diameter and late luminal changes were assessed. RESULTS: The recanalization was considered satisfactory in 79.4% (n=27). Restenosis occurred in 11.8% (n=4) and reocclusion in 5.9% (n=2). Out of the 27 patients with a satisfactory initial result, 3.7% (n=1) had reocclusion and 3.7% (n=1) had restenosis. In the subgroup without satisfactory result (n=7), restenosis occurred in 3 patients (42.9%) and reocclusion in 1 patient (14.3%). A luminal increase was found in 67.6% (n=23) and mean late luminal gain was 0.11±0.49mm. Angina class improved significantly (p<0.001). There was no death or myocardial infarction. CONCLUSIONS: Drug-coated balloon angioplasty without stenting is a feasible and well-tolerated treatment method for chronic total occlusions if the predilatation result is good.


Assuntos
Angioplastia Coronária com Balão/métodos , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/cirurgia , Stents Farmacológicos , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Doença Crônica , Angiografia Coronária/métodos , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/prevenção & controle , Estudos de Viabilidade , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Método Simples-Cego , Resultado do Tratamento
15.
Circulation ; 106(3): 319-24, 2002 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-12119247

RESUMO

BACKGROUND: Primary pulmonary hypertension (PPH) is a life-threatening disease. Prognostic assessment is an important factor in determining medical treatment and lung transplantation. Whether cardiopulmonary exercise testing data predict survival has not been reported previously. METHODS AND RESULTS: We studied 86 patients with PPH (58 female, age 46+/-2 years, median NYHA class III) between 1996 and 2001 who were followed up in a tertiary referral center. Right heart catheterization was performed and serum uric acid levels were measured in all patients. Seventy patients were able to undergo exercise testing. At the start of the study, the average pulmonary artery pressure was 60+/-2 mm Hg, average pulmonary vascular resistance was 1664+/-81 dyne x s x cm(-5), average serum uric acid level was 7.5+/-0.35 mg/dL, and average peak oxygen uptake during exercise (peak VO(2) was 11.2+/-0.5 mL x kg(-1) x min(-1). During follow-up (mean: 567+/-48 days), 28 patients died and 16 underwent lung transplantation (1-year cumulative event-free survival: 68%; 95% CI 58 to 78). The strongest predictors of impaired survival were low peak VO(2) (P<0.0001) and low systolic blood pressure at peak exercise (peak SBP; P<0.0001). In a multivariable analysis, serum uric acid levels (all P<0.005) and diastolic blood pressure at peak exercise independently predicted survival (P<0.05). Patients with peak VO(2) < or =10.4 mL x kg(-1) x min(-1) and peak SBP < or =120 mm Hg (ie, 2 risk factors) had poor survival rates at 12 months (23%), whereas patients with 1 or none of these risk factors had better survival rates (79% and 97%, respectively). CONCLUSIONS: Peak VO(2) and peak SBP are independent and strong predictors of survival in PPH patients. Hemodynamic parameters, although also accurate predictors, provide no independent prognostic information.


Assuntos
Hipertensão Pulmonar/mortalidade , Teste de Esforço , Feminino , Seguimentos , Hemodinâmica , Humanos , Hipertensão Pulmonar/diagnóstico , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Prospectivos , Ventilação Pulmonar , Fatores de Risco , Análise de Sobrevida , Ácido Úrico/sangue
16.
Clin Res Cardiol ; 104(3): 217-25, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25349065

RESUMO

BACKGROUND: This study investigated p aclitaxel-induced luminal changes following drug-coated balloon (DCB) angioplasty to treat coronary de novo lesions without additional stenting. DCB-mediated local drug delivery reduces late lumen loss in de novo coronary artery lesions. We performed a retrospective clinical assessment based on a pre-specified quantitative coronary angiography (QCA) protocol. METHODS: QCA was performed for each centre to assess the primary endpoint late lumen changes, i.e. the difference between in-lesion minimal lumen diameter (MLD) at the routine angiographic follow-up as compared to post-procedural in-lesion MLDs. These MLD changes were compared to corresponding reference vessel diameter changes as an intra-patient control. RESULTS: We evaluated 58 consecutive native coronary artery lesions directly after DCB angioplasty and at a routine target follow-up angiography of 4 months by QCA. Target lesion MLD increased significantly within the 4.1 ± 2.1 month observation period (1.75 ± 0.55 vs. 1.91 ± 0.55 mm, p < 0.001, diameter stenosis 33.8 ± 12.3 vs. 26.9 ± 13.8 %, p < 0.001), while there were no changes in non-target reference vessel diameters (2.33 ± 0.60 vs. 2.34 ± 0.61 mm, p = ns). A total of 69 % of patients showed luminal enlargement whereas 29 % had minor luminal loss. CONCLUSION: Local application of paclitaxel by DCB angioplasty to native coronary arteries after pre-dilatation without major dissection and recoil leads to late lumen increase.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Cateteres Cardíacos , Fármacos Cardiovasculares/administração & dosagem , Materiais Revestidos Biocompatíveis , Doença da Artéria Coronariana/terapia , Reestenose Coronária/prevenção & controle , Vasos Coronários/efeitos dos fármacos , Paclitaxel/administração & dosagem , Remodelação Vascular/efeitos dos fármacos , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/fisiopatologia , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/fisiopatologia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/fisiopatologia , Feminino , Humanos , Hiperplasia , Masculino , Pessoa de Meia-Idade , Neointima , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
17.
EuroIntervention ; 11(8): 926-34, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25169589

RESUMO

AIMS: Treatment of bare metal in-stent restenosis with the paclitaxel-coated balloon catheter based on the PACCOCATH® technology has yielded superior six-month angiographic and one-year clinical results compared to a paclitaxel-eluting stent. The three-year clinical follow-up is presented. METHODS AND RESULTS: One hundred and thirty-one patients with coronary bare metal in-stent restenosis (>70%, length: <22 mm, vessel diameter: 2.5-3.5 mm) were randomly treated with the paclitaxel-coated balloon (DCB) (3 µg/mm²) or a paclitaxel-eluting stent (DES). Clinical follow-up information was requested from the patients and from their physicians. Quantitative angiographic and demographic baseline data were statistically not different between the groups. Per intention-to-treat analysis at 12 months, the lesion-related rates of major adverse cardiac events were 7.6% and 16.9% (p=0.11) while at 36 months the respective numbers were 9.1% and 18.5% (p=0.14). These differences were primarily due to reduced target lesion revascularisation (TLR) in DCB 4/66 (6.2%) compared to DES patients 10/65 (15.4%) (p=0.10). From 12 to 36 months, 1/65 (1.5%) DCB patients experienced a myocardial infarction while neither TLR nor death occurred in any study patient in either group during that period. CONCLUSIONS: The six-month superiority of the paclitaxel-coated balloon compared to the paclitaxel-eluting stent in the treatment of bare metal coronary in-stent restenosis persisted throughout the three-year clinical follow-up period indicating stability of the lesions treated. (ClinicalTrials.gov Identifier: NCT00393315).


Assuntos
Angioplastia Coronária com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Materiais Revestidos Biocompatíveis , Doença da Artéria Coronariana/terapia , Reestenose Coronária/terapia , Stents Farmacológicos , Paclitaxel/administração & dosagem , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/instrumentação , Stents , Dispositivos de Acesso Vascular , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Reestenose Coronária/diagnóstico , Reestenose Coronária/etiologia , Intervalo Livre de Doença , Feminino , Alemanha , Humanos , Análise de Intenção de Tratamento , Estimativa de Kaplan-Meier , Masculino , Metais , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Inibidores da Agregação Plaquetária/uso terapêutico , Desenho de Prótese , Retratamento , Fatores de Tempo , Resultado do Tratamento
18.
J Thorac Cardiovasc Surg ; 126(4): 983-91, 2003 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-14566236

RESUMO

OBJECTIVE: Surgical intervention is an option for treating the remodeled and dilated left ventricles of patients with heart failure. Providing end-diastolic support with an innovative mesh-like cardiac support device reduces mechanical stress, improves function, and reverses cardiac remodeling in animal models without safety issues. The objective of this study was to review the global clinical safety and feasibility experience of this device. METHODS: The Acorn CorCap cardiac support device (Acorn Cardiovascular, Inc, St Paul, Minn) has been implanted worldwide in more than 130 patients with dilated cardiomyopathy with or without concomitant cardiac surgery. The device is positioned around the ventricles and given a custom fit. A series of 48 patients were implanted with the device in initial safety and feasibility studies, of whom 33 also received concomitant cardiac surgery. RESULTS: At implantation, 11 patients were in New York Heart Association class II, 33 were in class III, and 4 were in class IV. The average CorCap implantation time was 27 minutes. The mean intraoperative reduction in left ventricular end-diastolic dimension was 4.6% +/- 1%. There were no device-related intraoperative complications. Eight early and 9 late deaths occurred during follow-up extending to 24 months. Actuarial survival was 73% at 12 months and 68% at 24 months. There were no device-related adverse events or evidence of constrictive disease, and coronary artery flow reserve was maintained. Ventricular chamber dimensions decreased, whereas ejection fraction and New York Heart Association class were improved in patients overall and in those patients implanted with the CorCap device without concomitant operations. CONCLUSIONS: The CorCap device appears safe for patients with dilated cardiomyopathy. Randomized clinical trials are underway in Europe, Australia, and North America.


Assuntos
Cardiomiopatia Dilatada/cirurgia , Coração Auxiliar , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Viabilidade , Feminino , Seguimentos , Ventrículos do Coração , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/cirurgia , Desenho de Prótese , Implantação de Prótese , Segurança , Resultado do Tratamento
20.
Congest Heart Fail ; 10(2): 96-104; discussion 105, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15073455

RESUMO

Preclincial studies have shown that an innovative meshlike cardiac support device (CorCap, Acorn Cardiovascular, Inc., St. Paul, MN) can provide end diastolic support to reduce mechanical stress, improve function, and reverse cardiac remodeling. The CorCap device has been implanted worldwide in more than 130 patients with dilated cardiomyopathy (idiopathic or ischemic), with or without concomitant cardiac surgery. A series of 48 patients was implanted in initial safety and feasibility studies (33 received concomitant cardiac surgery, 15 patients received the CorCap device only). At implant, 33 patients were in New York Heart Association functional class III, 11 in class II, and four in class IV. There were no device-related intraoperative complications, deaths, or adverse events. Eight early and nine late deaths occurred during follow-up extending to 18-24 months. During follow-up, chamber dimensions decreased, and ejection fraction and New York Heart Association functional class improved. The CorCap device is correlated with improvements in patient functional status. Randomized clinical trials are underway in Europe, Australia, and North America.


Assuntos
Insuficiência Cardíaca/terapia , Coração Auxiliar , Remodelação Ventricular/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Coração Artificial , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa