Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 127
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 98(4): 788-799, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34051135

RESUMO

OBJECTIVES: The French left atrial appendage (LAA) closure registry (FLAAC) aimed to assess the safety and efficacy of LAA closure in daily practice. BACKGROUND: LAA closure has emerged as an alternative for preventing thromboembolic events (TE) in patients with non-valvular atrial fibrillation (NVAF). Clinical data in this field remains limited and few investigator-initiated, real-world registries have been reported. METHODS: This nationwide, prospective study was performed in 36 French centers. The primary endpoint was the TE rate after successful LAA closure. RESULTS: The FLAAC registry included 816 patients with a mean age of 75.5 ± 0.3 years, mean follow-up of 16.0 ± 0.3 months, high TE (CHA2 DS2 -VASc score: 4.6 ± 0.1) and bleeding risks (HAS-BLED score: 3.2 ± 0.05) and common contraindications to long-term anticoagulation (95.7%). Procedure or device-related serious adverse events occurred in 49 (6.0%) patients. The annual rate of ischemic stroke/systemic embolism was 3.3% (2.4-4.6). This suggests a relative 57% reduction compared to the risk of stroke in historical NVAF populations without antithrombotic therapy. By multivariate analysis, history of TE was the only factor associated with stroke/systemic embolism during follow-up (HR, 3.3 [1.58-6.89], p = 0.001). The annual mortality rate was 10.2% (8.4-12.3). Most of the deaths were due to comorbidities or underlying cardiovascular diseases and unrelated to the device or to TE. CONCLUSIONS: Our study suggests that LAA closure can be an option in patients with NVAF. Long-term follow-up mortality was high, mostly due to comorbidities and underlying cardiovascular diseases, highlighting the importance of multidisciplinary management after LAA closure. REGISTRATION: NCT02252861.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Acidente Vascular Cerebral , Idoso , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Humanos , Estudos Prospectivos , Sistema de Registros , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Resultado do Tratamento
2.
Circulation ; 140(4): 293-302, 2019 07 23.
Artigo em Inglês | MEDLINE | ID: mdl-31155932

RESUMO

BACKGROUND: An accurate estimation of the risk of life-threatening (LT) ventricular tachyarrhythmia (VTA) in patients with LMNA mutations is crucial to select candidates for implantable cardioverter-defibrillator implantation. METHODS: We included 839 adult patients with LMNA mutations, including 660 from a French nationwide registry in the development sample, and 179 from other countries, referred to 5 tertiary centers for cardiomyopathies, in the validation sample. LTVTA was defined as (1) sudden cardiac death or (2) implantable cardioverter defibrillator-treated or hemodynamically unstable VTA. The prognostic model was derived using the Fine-Gray regression model. The net reclassification was compared with current clinical practice guidelines. The results are presented as means (SD) or medians [interquartile range]. RESULTS: We included 444 patients, 40.6 (14.1) years of age, in the derivation sample and 145 patients, 38.2 (15.0) years, in the validation sample, of whom 86 (19.3%) and 34 (23.4%) experienced LTVTA over 3.6 [1.0-7.2] and 5.1 [2.0-9.3] years of follow-up, respectively. Predictors of LTVTA in the derivation sample were: male sex, nonmissense LMNA mutation, first degree and higher atrioventricular block, nonsustained ventricular tachycardia, and left ventricular ejection fraction (https://lmna-risk-vta.fr). In the derivation sample, C-index (95% CI) of the model was 0.776 (0.711-0.842), and the calibration slope 0.827. In the external validation sample, the C-index was 0.800 (0.642-0.959), and the calibration slope was 1.082 (95% CI, 0.643-1.522). A 5-year estimated risk threshold ≥7% predicted 96.2% of LTVTA and net reclassified 28.8% of patients with LTVTA in comparison with the guidelines-based approach. CONCLUSIONS: In comparison with the current standard of care, this risk prediction model for LTVTA in laminopathies significantly facilitated the choice of candidates for implantable cardioverter defibrillators. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov. Unique identifier: NCT03058185.


Assuntos
Cardiomiopatias/complicações , Desfibriladores Implantáveis/efeitos adversos , Taquicardia Ventricular/etiologia , Adulto , Feminino , Humanos , Masculino , Taquicardia Ventricular/patologia , Estudos de Validação como Assunto
3.
Eur Heart J ; 40(26): 2121-2127, 2019 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-31046090

RESUMO

AIMS: The very long-term outcome of patients who survive the first few years after receiving cardiac resynchronization therapy (CRT) has not been well described thus far. We aimed to provide long-term outcomes, especially with regard to the occurrence of sudden cardiac death (SCD), in CRT patients without (CRT-P) and with defibrillator (CRT-D). METHODS AND RESULTS: A total of 1775 patients, with ischaemic or non-ischaemic dilated cardiomyopathy, who were alive 5 years after CRT implantation, were enrolled in this multicentre European observational cohort study. Overall long-term mortality rates and specific causes of death were assessed, with a focus on late SCD. Over a mean follow-up of 30 months (interquartile range 10-42 months) beyond the first 5 years, we observed 473 deaths. The annual age-standardized mortality rates of CRT-D and CRT-P patients were 40.4 [95% confidence interval (CI) 35.3-45.5] and 97.2 (95% CI 85.5-109.9) per 1000 patient-years, respectively. The adjusted hazard ratio (HR) for all-cause mortality was 0.99 (95% CI 0.79-1.22). Twenty-nine patients in total died of late SCD (14 with CRT-P, 15 with CRT-D), corresponding to 6.1% of all causes of death in both device groups. Specific annual SCD rates were 8.5 and 5.8 per 1000 patient-years in CRT-P and CRT-D patients, respectively, with no significant difference between groups (adjusted HR 1.0, 95% CI 0.45-2.44). Death due to progressive heart failure represented the principal cause of death (42.8% in CRT-P patients and 52.6% among CRT-D recipients), whereas approximately one-third of deaths in both device groups were due to non-cardiovascular death. CONCLUSION: In this first description of very long-term outcomes among CRT recipients, progressive heart failure death still represented the most frequent cause of death in patients surviving the first 5 years after CRT implant. In contrast, SCD represents a very low proportion of late mortality irrespective of the presence of a defibrillator.


Assuntos
Terapia de Ressincronização Cardíaca/mortalidade , Morte Súbita Cardíaca/epidemiologia , Idoso , Estudos de Coortes , Desfibriladores Implantáveis , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pontuação de Propensão , Fatores de Risco , Índice de Gravidade de Doença , Análise de Sobrevida , Fatores de Tempo
4.
Eur Radiol ; 29(6): 3027-3035, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30402702

RESUMO

OBJECTIVE: To evaluate whether the epicardial adipose tissue (EAT) phenotype is associated with the electrophysiological properties of adjacent atrial myocardium in patients with atrial fibrillation (AF). METHODS: Between January and May 2017, 30 consecutive patients referred for a first AF catheter ablation were prospectively included. For each patient, a pre-procedural computed tomography scan was performed to assess total and left atrial (LA) EAT amount and radiodensity. A detailed point-by-point voltage mapping using an electroanatomic mapping system was realized to assess the presence of LA low-voltage zone (LVZ). RESULTS: Ten patients (33.3%) presented at least one LVZ. Older age (65 ± 7 vs. 58 ± 10 years, p = 0.05) was the only clinical parameter associated with LVZ. Despite no greater LA-EAT thickness by CT scan (3.0 [2.6-3.5] mm vs. 2.8 [2.2-3.1] mm, p = 0.354), patients with LA-LVZ presented significantly lower LA-EAT radiodensity than patients with no LA-LVZ (- 101.8 ± 12.5 HU vs. - 90.4 ± 6.3 HU, p = 0.004). No difference between total-EAT volume (131 ± 61 cm3 vs.107 ± 58 cm3, p = 0.361) and total-EAT radiodensity (- 106.8 ± 4.3 HU vs. - 102.4 ± 6.9 HU, p = 0.119) was found. CONCLUSION: Low LA-EAT radiodensity is associated with the presence of LVZ in patients with medical history of AF. KEY POINTS: • Cardiovascular risk factors are associated with low adipose tissue computed tomography attenuation. • Epicardial adipose tissue (EAT) has emerged as an important factor in the pathogenesis of metabolic-related cardiac diseases such as atrial fibrillation. • We showed that low left atrial EAT attenuation is associated with the presence of low-voltage zone, a surrogate for atrial fibrosis, within the adjacent myocardium.


Assuntos
Tecido Adiposo/patologia , Fibrilação Atrial/diagnóstico , Mapeamento Potencial de Superfície Corporal/métodos , Átrios do Coração/diagnóstico por imagem , Pericárdio/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Feminino , Seguimentos , Átrios do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Risco
5.
Europace ; 21(12): 1833-1842, 2019 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-31436840

RESUMO

AIMS: Limited data exist on the efficacy of catheter ablation (CA) for sport-related atrial fibrillation (AF). Impact of sports practice resumption post-CA remains unknown. We aimed to determine AF CA efficacy in athletes vs. non-athletes, and to assess the impact of sport practice resumption. METHODS AND RESULTS: From 1153 first-time AF CA performed between 2009 and 2017, 73 athletes were matched with 73 sedentary patients based on age, sex, and closest CA procedure date. Athletes were defined as performing ≥6 h/week of vigorous sports to achieve ≥2000 h accumulated lifetime sports activity. They were mostly males (93.2%) with a mean age of 55 ± 9.8 years. Before CA, athletes practiced 10.2 ± 3.9 h/week of vigorous exercise vs. 4.6 ± 3.4 after CA. Within first year after CA, physical activity was stopped in 12 (16.4%) athletes, lowered in 45 (61.9%), and resumed at same intensity in 16 (21.9%). Athletes and non-athletes suffered from same AF recurrence rates during 5-year follow-up after CA: 38 (52.0%) vs. 35 (47.9%), respectively [adjusted hazard ratio (HR) on age, body mass index (BMI), obstructive sleep apnoea (OSA), and reduced left ventricular ejection fraction (LVEF), 1.17 (0.70-1.97, P = 0.54)]. No significant impact of physical activity resumption status was found regarding AF recurrence rates at 1-year and beyond (P = 0.60). Procedure effectiveness was significantly lower in athletes with non-paroxysmal AF [adjusted on age, BMI, reduced LVEF, and OSA HR 2.36 (confidence interval 1.19-4.70), P = 0.01]. CONCLUSION: Sports practice before and after CA has no significant impact on AF recurrence rates in athletes within 5-year after AF CA.


Assuntos
Atletas , Fibrilação Atrial/cirurgia , Remodelamento Atrial , Ablação por Cateter , Volta ao Esporte , Remodelação Ventricular , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Estudos de Casos e Controles , Ecocardiografia , Treino Aeróbico , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Modelos de Riscos Proporcionais , Recidiva , Fatores de Risco , Comportamento Sedentário , Volume Sistólico , Resultado do Tratamento
6.
Europace ; 21(4): 607-615, 2019 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-30605510

RESUMO

AIMS: Implantable cardioverter-defibrillators (ICDs) reduce sudden cardiac death in selected patients but inappropriate ICD shocks have been associated with increased mortality. The THORN registry aims to describe the rate of inappropriate ventricular arrhythmia diagnoses and therapies in patients followed by remote monitoring, as well as the following delay to next patient contact (DNPC). METHODS AND RESULTS: One thousand eight hundred and eighty-two patients issued from a large remote monitoring database first implanted with an ICD for primary or secondary prevention in 110 French hospitals from 2007 to 2014 constitute the THORN population. Among them, 504 patients were additionally followed prospectively for evaluation of the DNPC. Eight hundred and ninety-five out of 1551 (58%) patients had ischaemic heart disease and 358/771 (46%) were implanted for secondary prevention. During 13.7 ± 3.4 months of follow-up, the prevalence of first inappropriate diagnosis in a ventricular arrhythmia zone with enabled therapy was 162/1882 (9%). Among those patients, 122/162 (75%) suffered at least one inappropriate therapy and 58/162 (36%) at least one inappropriate shock. Eighty-three out of 162 (51%) of first inappropriate diagnosis occurred during the first 4 months following implantation. The median DNPC was 8 days (interquartile range 1-26). At least one other day with recording of an inappropriate diagnosis of the same cause occurred in 13/43 (30%) of available DNPC periods, with an inappropriate therapy in 7/13 (54%). CONCLUSION: Inappropriate diagnoses occurred in 9% of patients implanted with an ICD during the first 14 months. The DNPC after inadequate ventricular arrhythmia diagnoses remains long in daily practice and should be optimized. CLINICALTRIALS.GOV IDENTIFIER: NCT01594112.


Assuntos
Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Cardioversão Elétrica/estatística & dados numéricos , Taquicardia Supraventricular/diagnóstico , Taquicardia Ventricular/diagnóstico , Fibrilação Ventricular/diagnóstico , Idoso , Erros de Diagnóstico , Feminino , França , Humanos , Masculino , Pessoa de Meia-Idade , Prevenção Primária , Sistema de Registros , Tecnologia de Sensoriamento Remoto , Prevenção Secundária , Taquicardia Ventricular/terapia , Fatores de Tempo , Fibrilação Ventricular/terapia
7.
Europace ; 21(7): 1063-1069, 2019 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-30891608

RESUMO

AIMS: Current guidelines do not propose any age cut-off for the primary prevention implantable cardioverter-defibrillator (ICD). However, the risk/benefit balance in the very elderly population has not been well studied. METHODS AND RESULTS: In a multicentre French study assessing patients implanted with an ICD for primary prevention, outcomes among patients aged ≥80 years were compared with <80 years old controls matched for sex and underlying heart disease (ischaemic and dilated cardiomyopathy). A total of 300 ICD recipients were enrolled in this specific analysis, including 150 patients ≥80 years (mean age 81.9 ± 2.0 years; 86.7% males) and 150 controls (mean age 61.8 ± 10.8 years). Among older patients, 92 (75.6%) had no more than one associated comorbidity. Most subjects in the elderly group got an ICD as part of a cardiac resynchronization therapy procedure (74% vs. 46%, P < 0.0001). After a mean follow-up of 3.0 ± 2 years, 53 patients (35%) in the elderly group died, including 38.2% from non cardiovascular causes of death. Similar proportion of patients received ≥1 appropriate therapy (19.4% vs. 21.6%; P = 0.65) in the elderly group and controls, respectively. There was a trend towards more early perioperative events (P = 0.10) in the elderly, with no significant increase in late complications (P = 0.73). CONCLUSION: Primary prevention ICD recipients ≥80 years in the real world had relatively low associated comorbidity. Rates of appropriate therapies and device-related complications were similar, compared with younger subjects. Nevertheless, the inherent limitations in interpreting observational data on this particular competing risk situation call for randomized controlled trials to provide definitive answers. Meanwhile, a careful multidisciplinary evaluation is needed to guide patient selection for ICD implantation in the elderly population.


Assuntos
Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Prevenção Primária , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Feminino , França , Humanos , Masculino , Pessoa de Meia-Idade
8.
Pacing Clin Electrophysiol ; 42(3): 349-355, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30609077

RESUMO

INTRODUCTION: Several clinical studies have demonstrated that remote monitoring (RM) offers potential benefits in transvenous implantable cardioverter defibrillator (ICD). The potential interest of RM in subcutaneous-ICD (S-ICD) recipients has never been evaluated. The aim of this study was to evaluate the alert burden and its clinical relevance in a prospective cohort of S-ICD recipients. METHODS: We prospectively and consecutively enrolled all patients undergoing S-ICD implantation at Lille University Hospital from September 2015 to January 2017 and gave them a LATITUDE™ NXT RM system. The relevance of transmissions was assessed by the following ratio: number of transmissions leading to reaction or intervention per patient/number of transmissions per patient. RESULTS: From September 2015 to January 2017, 69 patients were enrolled with a mean follow-up of 415 ± 96.3 days. The mean age was 44.6 ± 15.6 years old, and 25% (n = 17) had ischemic cardiomyopathy. At the end of follow-up, 12% of the patients had events recorded by RM. These events were related to nine ICD shocks and eight untreated events. A total of 1,423 transmissions were collected. Most of these transmissions were patient-initiated without any event (77%, n = 1,096) or scheduled without any event (19%, n = 272). Only 3.2% ± 1.1 of the transmissions per patient led to reactions or interventions. CONCLUSION: On the basis of the current method of transmitting, S-ICD RM allowed detection of relevant events in 12% of patients but generated a high unactionable transmission burden. As a result of these findings, efforts should be made to optimize transmissions considering automatic transmissions and to focus on patient education.


Assuntos
Cardiomiopatias/terapia , Desfibriladores Implantáveis , Tecnologia de Sensoriamento Remoto/métodos , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sistema de Registros
9.
Europace ; 20(2): 362-369, 2018 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-28017936

RESUMO

Aims: Studies assessing radiofrequency ablation (RFA) of ventricular tachycardia (VT) in arrhythmogenic right ventricular cardiomyopathy (ARVC) report VT recurrences, but have not evaluated the impact of RFA on relevant clinical events during follow-up. We aimed to investigate relevant RFA outcomes in a multicentric registry. Methods and results: This study included 49 patients with ARVC (46 with definite diagnosis, 3 with borderline diagnosis according to revised Task Force Criteria) who underwent 92 RFA procedures (83 endocardial, 9 combined endo-epicardial) between 1999-2015. Ventricular tachycardia recurrences and VT burden were assessed after each procedure or after the last RFA. Over a mean follow-up of 64 ± 51 months, VT-free survival was 37% at 1 year, 19% at 5 years, and 14% at 10 years. Ventricular tachycardia burden was significantly reduced after one procedure (23 vs. 11 VT episodes/year, P < 0.01) and after the last RFA (14 vs. 2 VT episodes/year, P < 0.01). Over a mean follow-up of 49 ± 52 months, clinical response after the last RFA (freedom from sudden cardiac death, VT requiring hospitalization, or heart transplantation) was 86% at 1 year, 69% at 5 years, and 60% at 10 years. Clinical response was associated with right ventricular dysfunction (RVD) and low numbers of mappable VT before the first RFA. Conclusion: RFA was predominantly targeted at the endocardial surface. Ventricular tachycardia recurrences were common, but few ARVC patients experienced major clinical events during follow-up. Further studies should investigate the benefit of extensive substrate ablation combined with endo-epicardial strategies.


Assuntos
Displasia Arritmogênica Ventricular Direita/complicações , Ablação por Cateter , Taquicardia Ventricular/cirurgia , Adulto , Displasia Arritmogênica Ventricular Direita/diagnóstico , Displasia Arritmogênica Ventricular Direita/fisiopatologia , Ablação por Cateter/efeitos adversos , Intervalo Livre de Doença , Feminino , França , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
10.
Europace ; 20(1): 65-72, 2018 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-28082419

RESUMO

Aim: The magnitude of benefit related to implantable cardioverter defibrillator (ICD) therapy for primary prevention of sudden cardiac death (SCD) in non-ischaemic cardiomyopathy (NICM) and ischaemic cardiomyopathy (ICM) has not been evaluated extensively in clinical practice. Methods and results: Of the 5539 consecutive patients enrolled in the multicentre Défibrillateur Automatique Implantable-Prévention Primaire (DAI-PP) study (2002-12), 5485 patients (with information on underlying heart disease) were included in the present analysis: 2181 (39.8%) had NICM and 3304 (60.2%) had ICM. ICM patients were older (63.7 ±10.3 vs. 60.6 ± 12.2 years, P < 0.0001), with a higher ejection fraction [27% (25-30) vs. 25% (20-30), P < 0.0001], narrower QRS (37.3% vs. 21.4% with QRS <120, P < 0.0001), and higher prevalence of sinus rhythm (77.3% vs. 74.0%, P = 0.009). During a mean follow-up of 3.1 ± 2.2 years, 814 patients died, giving a mortality incidence of 48.6 per 1000 person-years [95% confidence interval (CI) 45.2-51.9], higher among ICM patients (52.3, 95% CI 47.8-56.7) than in NICM patients (42.4, 95% CI 37.3-47.6; P = 0.008) (adjusted hazard ratio 1.31, 95% CI 1.06-1.61, P = 0.01). The increase in mortality among ICM patients was mainly due to non-cardiovascular mortality (P = 0.0002), whereas incidences of cardiovascular mortality (including ICD-unresponsive SCD) were similar in the two groups. Incidences of appropriate ICD interventions (anti-tachycardia pacing, shocks) were similar, but inappropriate therapies were more frequent in NICM (7.94 vs. 5.96%; P = 0.005). Conclusion: NICM and ICM patients had a same rate of ICD therapy for primary prevention of SCD in everyday practice. But, ICM patients more often died of a non- cardiovascular cause of death. Clinical Trial Registration: NCT 01992458.


Assuntos
Cardiomiopatias/terapia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Isquemia Miocárdica/epidemiologia , Prevenção Primária/instrumentação , Idoso , Cardiomiopatias/diagnóstico , Cardiomiopatias/mortalidade , Cardiomiopatias/fisiopatologia , Causas de Morte , Morte Súbita Cardíaca/epidemiologia , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/mortalidade , Feminino , França/epidemiologia , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/diagnóstico , Isquemia Miocárdica/mortalidade , Isquemia Miocárdica/fisiopatologia , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
11.
Pacing Clin Electrophysiol ; 41(10): 1378-1380, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29989676

RESUMO

Catecholaminergic polymorphic ventricular tachycardia (CPVT) is a potentially lethal hereditary disease characterized by complex ventricular arrhythmias provoked by exercise or emotional stress and by a high mortality rate in young individuals. Nadolol alone or in combination with flecainide is the most effective therapy. However, compliance to treatment is often low due to side effects. We report two patients with CPVT in whom side effects of treatment prompted discontinuation of flecainide or nadolol and in whom ivabradine was successfully added to therapy. In these two patients, ivabradine in combination with nadolol or flecainide was well tolerated and successfully suppressed nonsustained polymorphic ventricular tachycardia and couplets. Thus, ivabradine could limit the use of implantable cardioverter-defibrillators or left cardiac sympathetic denervation in CPVT patients with uncontrollable ventricular arrhythmias.


Assuntos
Fármacos Cardiovasculares/uso terapêutico , Ivabradina/uso terapêutico , Taquicardia Ventricular/tratamento farmacológico , Adolescente , Antiarrítmicos/uso terapêutico , Eletrocardiografia , Teste de Esforço , Feminino , Flecainida/uso terapêutico , Humanos , Masculino , Nadolol/uso terapêutico , Taquicardia Ventricular/fisiopatologia , Adulto Jovem
12.
Eur Heart J ; 38(10): 751-758, 2017 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-27941019

RESUMO

AIMS: To describe the incidence and identify predictors of sudden death (SD), major conduction defects and sustained ventricular tachyarrhythmias (VTA) in myotonic dystrophy type 1 (DM1). METHODS AND RESULTS: We retrospectively enrolled 1388 adults with DM1 referred to six French medical centres between January 2000 and October 2013. We confirmed their vital status, classified all deaths, and determined the incidence of major conduction defects requiring permanent pacing and sustained VTA. We searched for predictors of overall survival, SD, major conduction defects, and sustained VTA by Cox regression analysis. Over a median 10-year follow-up, 253 (18.2%) patients died, 39 (3.6%) suddenly. Analysis of the cardiac rhythm at the time of the 39 SD revealed sustained VTA in 9, asystole in 5, complete atrioventricular block in 1 and electromechanical dissociation in two patients. Non-cardiac causes were identified in the five patients with SD who underwent autopsies. Major conduction defects developed in 143 (19.3%) and sustained VTA in 26 (2.3%) patients. By Cox regression analysis, age, family history of SD and left bundle branch block were independent predictors of SD, while age, male sex, electrocardiographic conduction abnormalities, syncope, and atrial fibrillation were independent predictors of major conduction defects; non-sustained VTA was the only predictor of sustained VTA. CONCLUSIONS: SD was a frequent mode of death in DM1, with multiple mechanisms involved. Major conduction defects were by far more frequent than sustained VTA, whose only independent predictor was a personal history of non-sustained VTA. ClinicalTrials.gov no: NCT01136330.


Assuntos
Doença do Sistema de Condução Cardíaco/etiologia , Morte Súbita Cardíaca/etiologia , Distrofia Miotônica/complicações , Adulto , Fatores Etários , Bloqueio Atrioventricular/etiologia , Bloqueio Atrioventricular/mortalidade , Bloqueio de Ramo/etiologia , Bloqueio de Ramo/mortalidade , Doença do Sistema de Condução Cardíaco/mortalidade , Estimulação Cardíaca Artificial , Desfibriladores Implantáveis , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Distrofia Miotônica/mortalidade , Linhagem , Estudos Retrospectivos , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/mortalidade
13.
J Cardiovasc Electrophysiol ; 28(6): 666-673, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28251724

RESUMO

BACKGROUND: Technology and clinical practice surrounding the use of the primary prevention implantable cardioverter defibrillator (ICD) are in a state of constant evolution. The purpose of the study was to test the hypothesis of significant temporal trends in characteristics and outcomes over a decade of ICD therapy. METHODS: Between 2002 and 2012, 5,539 consecutive patients (age 62.5 ± 11 years, 84.9% male), with ischemic or nonischemic cardiomyopathy, implanted with a primary prevention ICD from 12 centers in France were included. Information on characteristics and outcomes (including causes of death) were evaluated over a median follow-up of 994 days (466-1,667). RESULTS: In addition to a shift in the type of devices implanted with a significant increase in cardiac resynchronization therapy-defibrillator (CRT-D) over time (43.6 to 60.4%, P = 0.0001), an increase in mean age (from 61.5 ± 11.6 to 63.2 ± 10.9 years, P = 0.0016), proportion of nonischemic cardiomyopathy (31.0 to 44.7%, P <0.0001) and women recipients (11.4 to 15.8%, P = 0.004) was observed. A total of 1,181 patients (22.3%) received ≥1 appropriate therapy, inappropriate therapies occurred in 355 patients (6.7%) and 826 patients (15.2%) died, mainly from cardiovascular causes (49.3%). Annual mortality incidence (5.4% to 4.3%, P = 0.05), as well as incidence of appropriate therapy (10.4% to 7.1%, P = 0.0004), significantly decreased over the decade. By contrast, incidence of ICD-related late (>30 days after implant) complications significantly increased (4.6 to 7.6%, P = 0.003). CONCLUSION: Our findings demonstrate significant changes in patterns of use and outcomes in primary prevention ICD over the last decade with reductions in mortality and appropriate therapies, counterbalanced by an increase in complications.


Assuntos
Terapia de Ressincronização Cardíaca/tendências , Cardiomiopatias/terapia , Serviços de Saúde Comunitária/tendências , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis/tendências , Cardioversão Elétrica/tendências , Padrões de Prática Médica/tendências , Prevenção Primária/tendências , Idoso , Terapia de Ressincronização Cardíaca/efeitos adversos , Terapia de Ressincronização Cardíaca/mortalidade , Cardiomiopatias/diagnóstico , Cardiomiopatias/mortalidade , Cardiomiopatias/fisiopatologia , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/instrumentação , Cardioversão Elétrica/mortalidade , Feminino , França , Humanos , Masculino , Pessoa de Meia-Idade , Prevenção Primária/instrumentação , Modelos de Riscos Proporcionais , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
14.
Europace ; 19(9): 1478-1484, 2017 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-28340096

RESUMO

AIMS: Implantable cardioverter defibrillators (ICDs) are an effective primary prevention of sudden cardiac death. We examined whether dual-chamber (DC) ICDs confer a greater benefit than single-chamber (SC) ICDs, and compared the long-term outcomes of recipients of each type of device implanted for primary prevention. METHODS AND RESULTS: Between 2002 and 2012, the DAI-PP registry consecutively enrolled 1258 SC- and 1280 DC-ICD recipients at 12 French medical centres. The devices were interrogated at 4- to 6-month intervals during outpatient visits, with a focus on the therapies delivered. The study endpoints were incidence of appropriate therapies, ICD-related morbidity, and deaths from all and from specific causes. The mean age of the SC- and DC-ICD recipients was 59 ± 12 and 62 ± 11 years, respectively (P< 0.0001). The distribution of genders, New York Heart Association functional classes and glomerular filtration rates, and the rates of ischaemic vs. dilated cardiomyopathies and of defibrillation tests at implant, were similar in both study groups. The rates of periprocedural complications were 12.1% in the DC- vs. 8.8% in the SC-ICD groups (P= 0.008). Over a mean follow-up of 3.1 ± 2.2 years, pulse generators were replaced in 21.9% of the DC- vs. 13.6% of the SC-ICD group (P< 0.0001). The proportions of patients treated with ≥1 appropriate therapies (24.7 vs. 23.8%) and ≥1 inappropriate shocks (8.4 vs. 7.8%), and all-cause mortality (12.4 vs. 13.2%) were similar in both groups. CONCLUSION: In this large registry of ICD implanted for primary prevention, DC-ICDs were associated with higher rates of peri-implant complications and generator replacements, whereas the survival and rates of inappropriate shocks were similar in both groups. CLINICAL TRIAL NUMBER: NCT#01992458.


Assuntos
Arritmias Cardíacas/terapia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Prevenção Primária/instrumentação , Idoso , Arritmias Cardíacas/complicações , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/mortalidade , Causas de Morte , Morte Súbita Cardíaca/etiologia , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/mortalidade , Feminino , França , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Falha de Prótese , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
15.
Europace ; 19(4): 651-659, 2017 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-28431061

RESUMO

AIMS: Mutations in PRKAG2, the gene encoding for the γ2 subunit of 5'-AMP-activated protein kinase (AMPK), are responsible for an autosomal dominant glycogenosis with a cardiac presentation, associating hypertrophic cardiomyopathy (HCM), ventricular pre-excitation (VPE), and progressive heart block. The aim of this study was to perform a retrospective time-to-event study of the clinical manifestations associated with PRKAG2 mutations. METHODS AND RESULTS: A cohort of 34 patients from 9 families was recruited between 2001 and 2010. DNA were sequenced on all exons and flanking sequences of the PRKAG2 gene using Sanger sequencing. Overall, four families carried the recurrent p.Arg302Gln mutation, and the five others carried private mutations among which three had never been reported. In the total cohort, at 40 years of age, the risk of developing HCM was 61%, VPE 70%, conduction block 22%, and sudden cardiac death (SCD) 20%. The global survival at 60 years of age was 66%. Thirty-two per cent of patients (N = 10) required a device implantation (5 pacemakers and 5 defibrillators) at a median age of 66 years, and two patients required heart transplant. Only one patient presented with significant skeletal muscle symptoms. No significant differences regarding the occurrence of VPE, ablation complications, or death incidence were observed between different mutations. CONCLUSION: This study of patients with PRKAG2 mutations provides a more comprehensive view of the natural history of this disease and demonstrates a high risk of cardiac complications. Early recognition of this disease appears important to allow an appropriate management.


Assuntos
Proteínas Quinases Ativadas por AMP/genética , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/genética , Cardiomiopatia Hipertrófica/genética , Cardiomiopatia Hipertrófica/mortalidade , Doença de Depósito de Glicogênio/genética , Doença de Depósito de Glicogênio/mortalidade , Adulto , Comorbidade , Feminino , França/epidemiologia , Marcadores Genéticos/genética , Predisposição Genética para Doença/epidemiologia , Predisposição Genética para Doença/genética , Humanos , Masculino , Pessoa de Meia-Idade , Mutação/genética , Polimorfismo de Nucleotídeo Único/genética , Prevalência , Fatores de Risco , Taxa de Sobrevida
16.
Artigo em Inglês | MEDLINE | ID: mdl-28188661

RESUMO

Idiopathic epicardial ventricular tachycardias (VTs) account for 9% of idiopathic VTs. The recognition of this entity is important, as a minimally invasive ablation procedure performed exclusively through the coronary sinus branches may be considered, avoiding the potential risks associated with access to the left ventricular endocardium, the aortic root, and the pericardial space. The electrocardiographic features and therapeutic management of this rare form of tachycardia are discussed.


Assuntos
Ablação por Cateter/métodos , Eletrocardiografia/métodos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Pericárdio/fisiopatologia
17.
J Electrocardiol ; 50(5): 694-695, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28554515

RESUMO

Endocardial mapping is typically considered as the first step of VT ablation procedures. Nevertheless, when the electrocardiogram is highly suggestive of an epicardial VT, a minimally invasive procedure performed exclusively via the coronary sinus might be considered. This straightforward approach avoids all potential complications associated with access to the left ventricular endocardium, the aortic root, and the pericardial space.


Assuntos
Ablação por Cateter/métodos , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/cirurgia , Idoso , Mapeamento Potencial de Superfície Corporal/estatística & dados numéricos , Angiografia Coronária , Eletrocardiografia , Humanos , Masculino
18.
Europace ; 18(6): 820-7, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26498163

RESUMO

AIMS: Lead fractures in implantable cardioverter-defibrillator (ICD) patients may cause inappropriate shocks (ISs). An early diagnosis is essential to prevent adverse clinical events. Implantable cardioverter-defibrillator remote monitoring (RM) permits prompt detection of lead fracture. Limited data define the impact of RM on ISs specifically related to lead fracture. We sought to compare the number of ISs related to lead fracture in patients with vs. without RM follow-up. METHODS AND RESULTS: We checked the registry of our institution and collected, between July 2007 and June 2014, 115 cases of right ventricular lead fractures. All relevant data were documented from patients' files, device-interrogation printouts and electronic records, and remote transmissions databases when applicable. We assessed the ISs that were related to lead fracture. The first study endpoint was the number of ISs per shocked patient. Among the 82 patients with conventional follow-up (CFU) and the 33 patients with RM, a first IS occurred to 32.9% (n = 27) and 30.3% (n = 10, P = 0.83) of the patients, respectively. Shocked patients in the RM group underwent significantly fewer ISs with a mean of 6 ± 2 shocks per patient [median of 3.5 shocks (2-8)] than those in the CFU group with a mean of 18 ± 5 shocks per patient [median of 10 shocks (5-22), P = 0.03]. CONCLUSION: Remote monitoring helps to reduce the burden of ISs related to ICD lead fractures.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Cardioversão Elétrica/efeitos adversos , Falha de Equipamento , Tecnologia de Sensoriamento Remoto , Feminino , Seguimentos , França , Humanos , Masculino , Pessoa de Meia-Idade , Sistema de Registros
19.
Europace ; 18(12): 1809-1817, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26711741

RESUMO

AIMS: Despite increased use of remote monitoring (RM) to follow up implantable cardioverter-defibrillator (ICD) recipients, many patients still receive ICD shocks in the community and present to the emergency department. Our aim was to identify the best predictors of impending shock delivery that can be measured with an ICD and to identify the most appropriate activities to alert physicians to during RM follow-up. METHODS AND RESULTS: All patients presenting to our institution for ICD shock, from November 2011 to November 2014, were enrolled in this prospective study. Patient characteristics, investigation results, and details of electrical activities from ICD interrogation were recorded at presentation. Presentations were classified as potentially avoidable if activities from a list of set criteria were apparent more than 48 h before index shock. Univariate and multivariate analyses were then used to identify predictors of potentially avoidable shocks. In total, 109 emergency presentations were recorded in 90 patients (male: 85%; 57 ± 16 years; ischaemic cardiomyopathy: 49%; LVEF: 34 ± 13%; electrical storm: 40%), of which 26 (24%) were potentially avoidable. Antitachycardia pacing (ATP) episodes were the most important predictor of impending shock. Potentially avoidable shocks were preceded by more episodes of ATP than unavoidable shocks (13 [3-67] vs. 3 [0-10]; P < 0.001). Patients followed up with RM systems configured to generate alerts following ATP delivery experienced significantly less ICD shocks (24 vs. 16%, P < 0.01). CONCLUSION: Remote monitoring systems that generate alerts following ATP delivery could reduce emergency presentations for ICD shock by 24%, as ATP is a key predictor of impending shock delivery.


Assuntos
Estimulação Cardíaca Artificial/efeitos adversos , Desfibriladores Implantáveis , Cardioversão Elétrica/efeitos adversos , Tecnologia de Sensoriamento Remoto , Taquicardia Ventricular/terapia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Cardioversão Elétrica/instrumentação , Eletrocardiografia , Serviços Médicos de Emergência , Feminino , França , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica/métodos , Análise Multivariada , Isquemia Miocárdica/epidemiologia , Isquemia Miocárdica/etiologia , Estudos Prospectivos , Telemedicina , Disfunção Ventricular Esquerda/epidemiologia , Disfunção Ventricular Esquerda/etiologia , Adulto Jovem
20.
Eur Heart J ; 36(41): 2767-76, 2015 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-26330420

RESUMO

AIMS: The choice of resynchronization therapy between with (CRT-D) and without (CRT-P) a defibrillator remains a contentious issue. Cause-of-death analysis among CRT-P, compared with CRT-D, patients could help evaluate the extent to which CRT-P patients would have additionally benefited from a defibrillator in a daily clinical practice. METHODS AND RESULTS: A total of 1705 consecutive patients implanted with a CRT (CRT-P: 535 and CRT-D: 1170) between 2008 and 2010 were enrolled in CeRtiTuDe, a multicentric prospective follow-up cohort study, with specific adjudication for causes of death at 2 years. Patients with CRT-P compared with CRT-D were older (P < 0.0001), less often male (P < 0.0001), more symptomatic (P = 0.0005), with less coronary artery disease (P = 0.003), wider QRS (P = 0.002), more atrial fibrillation (P < 0.0001), and more co-morbidities (P = 0.04). At 2-year follow-up, the annual overall mortality rate was 83.80 [95% confidence interval (CI) 73.41-94.19] per 1000 person-years. The crude mortality rate among CRT-P patients was double compared with CRT-D (relative risk 2.01, 95% CI 1.56-2.58). In a Cox proportional hazards regression analysis, CRT-P remained associated with increased mortality (hazard ratio 1.54, 95% CI 1.07-2.21, P = 0.0209), although other potential confounders may persist. By cause-of-death analysis, 95% of the excess mortality among CRT-P subjects was related to an increase in non-sudden death. CONCLUSION: When compared with CRT-D patients, excess mortality in CRT-P recipients was mainly due to non-sudden death. Our findings suggest that CRT-P patients, as currently selected in routine clinical practice, would not potentially benefit with the addition of a defibrillator.


Assuntos
Terapia de Ressincronização Cardíaca/mortalidade , Insuficiência Cardíaca/mortalidade , Idoso , Dispositivos de Terapia de Ressincronização Cardíaca , Morte Súbita Cardíaca/epidemiologia , Desfibriladores Implantáveis , Métodos Epidemiológicos , Feminino , Insuficiência Cardíaca/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa