Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Sensors (Basel) ; 22(23)2022 Dec 02.
Artigo em Inglês | MEDLINE | ID: mdl-36502141

RESUMO

Solar-induced chlorophyll fluorescence (SIF) is used as a proxy of photosynthetic efficiency. However, interpreting top-of-canopy (TOC) SIF in relation to photosynthesis remains challenging due to the distortion introduced by the canopy's structural effects (i.e., fluorescence re-absorption, sunlit-shaded leaves, etc.) and sun-canopy-sensor geometry (i.e., direct radiation infilling). Therefore, ground-based, high-spatial-resolution data sets are needed to characterize the described effects and to be able to downscale TOC SIF to the leafs where the photosynthetic processes are taking place. We herein introduce HyScreen, a ground-based push-broom hyperspectral imaging system designed to measure red (F687) and far-red (F760) SIF and vegetation indices from TOC with single-leaf spatial resolution. This paper presents measurement protocols, the data processing chain and a case study of SIF retrieval. Raw data from two imaging sensors were processed to top-of-canopy radiance by dark-current correction, radiometric calibration, and empirical line correction. In the next step, the improved Fraunhofer line descrimination (iFLD) and spectral-fitting method (SFM) were used for SIF retrieval, and vegetation indices were calculated. With the developed protocol and data processing chain, we estimated a signal-to-noise ratio (SNR) between 50 and 200 from reference panels with reflectance from 5% to 95% and noise equivalent radiance (NER) of 0.04 (5%) to 0.18 (95%) mW m-2 sr-1 nm-1. The results from the case study showed that non-vegetation targets had SIF values close to 0 mW m-2 sr-1 nm-1, whereas vegetation targets had a mean F687 of 1.13 and F760 of 1.96 mW m-2 sr-1 nm-1 from the SFM method. HyScreen showed good performance for SIF retrievals at both F687 and F760; nevertheless, we recommend further adaptations to correct for the effects of noise, varying illumination and sensor optics. In conclusion, due to its high spatial resolution, Hyscreen is a promising tool for investigating the relationship between leafs and TOC SIF as well as their relationship with plants' photosynthetic capacity.


Assuntos
Clorofila , Fotossíntese , Estações do Ano , Luz Solar , Folhas de Planta
2.
Sensors (Basel) ; 19(24)2019 Dec 13.
Artigo em Inglês | MEDLINE | ID: mdl-31847146

RESUMO

Short-wave infrared (SWIR) imaging systems with unmanned aerial vehicles (UAVs) are rarely used for remote sensing applications, like for vegetation monitoring. The reasons are that in the past, sensor systems covering the SWIR range were too expensive, too heavy, or not performing well enough, as, in contrast, it is the case in the visible and near-infrared range (VNIR). Therefore, our main objective is the development of a novel modular two-channel multispectral imaging system with a broad spectral sensitivity from the visible to the short-wave infrared spectrum (approx. 400 nm to 1700 nm) that is compact, lightweight and energy-efficient enough for UAV-based remote sensing applications. Various established vegetation indices (VIs) for mapping vegetation traits can then be set up by selecting any suitable filter combination. The study describes the selection of the individual components, starting with suitable camera modules, the optical as well as the control and storage parts. Special bandpass filters are used to select the desired wavelengths to be captured. A unique flange system has been developed, which also allows the filters to be interchanged quickly in order to adapt the system to a new application in a short time. The characterization of the system was performed in the laboratory with an integrating sphere and a climatic chamber. Finally, the integration of the novel modular VNIR/SWIR imaging system into a UAV and a subsequent first outdoor test flight, in which the functionality was tested, are described.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa